Dell Wyse Datacenter for Vmware Horizon View Reference Architecture

Dell Wyse Datacenter for Vmware Horizon View Reference Architecture

Dell Wyse Datacenter for VMware Horizon View Reference Architecture A Reference Architecture for the design, configuration and implementation of a VMware Horizon View environment. Dell Wyse Solutions Engineering July 2015 A Dell Reference Architecture Revisions Date Description May 2014 Initial release (v.6.5) November 2014 Updated to include 13g servers and increased VM density (v.6.6) November 2014 Updated cloud client graphics and nomenclature (v.6.6.1) July 2015 Updated density numbers for ESXi 6.0 and added PowerEdge C4130 (v.6.7) 2 Dell Wyse Datacenter for VMware Horizon View Reference Architecture | v.6.7 THIS WHITE PAPER IS FOR INFORMATIONAL PURPOSES ONLY, AND MAY CONTAIN TYPOGRAPHICAL ERRORS AND TECHNICAL INACCURACIES. THE CONTENT IS PROVIDED AS IS, WITHOUT EXPRESS OR IMPLIED WARRANTIES OF ANY KIND. © 2015 Dell Inc. All rights reserved. Reproduction of this material in any manner whatsoever without the express written permission of Dell Inc. is strictly forbidden. For more information, contact Dell. PRODUCT WARRANTIES APPLICABLE TO THE DELL PRODUCTS DESCRIBED IN THIS DOCUMENT MAY BE FOUND AT: http://www.dell.com/learn/us/en/19/terms-of-sale-commercial-and-public-sector Performance of network reference architectures discussed in this document may vary with differing deployment conditions, network loads, and the like. Third party products may be included in reference architectures for the convenience of the reader. Inclusion of such third party products does not necessarily constitute Dell’s recommendation of those products. Please consult your Dell representative for additional information. Trademarks used in this text: Dell™, the Dell logo, Dell Boomi™, Dell Precision™ ,OptiPlex™, Latitude™, PowerEdge™, PowerVault™, PowerConnect™, OpenManage™, EqualLogic™, Compellent™, KACE™, FlexAddress™, Force10™ and Vostro™ are trademarks of Dell Inc. Other Dell trademarks may be used in this document. Cisco Nexus®, Cisco MDS®, Cisco NX- 0S®, and other Cisco Catalyst® are registered trademarks of Cisco System Inc. EMC VNX®, and EMC Unisphere® are registered trademarks of EMC Corporation. Intel®, Pentium®, Xeon®, Core® and Celeron® are registered trademarks of Intel Corporation in the U.S. and other countries. AMD® is a registered trademark and AMD Opteron™, AMD Phenom™ and AMD Sempron™ are trademarks of Advanced Micro Devices, Inc. Microsoft®, Windows®, Windows Server®, Internet Explorer®, MS-DOS®, Windows Vista® and Active Directory® are either trademarks or registered trademarks of Microsoft Corporation in the United States and/or other countries. Red Hat® and Red Hat® Enterprise Linux® are registered trademarks of Red Hat, Inc. in the United States and/or other countries. Novell® and SUSE® are registered trademarks of Novell Inc. in the United States and other countries. Oracle® is a registered trademark of Oracle Corporation and/or its affiliates. Citrix®, Xen®, XenServer® and XenMotion® are either registered trademarks or trademarks of Citrix Systems, Inc. in the United States and/or other countries. VMware®, Virtual SMP®, vMotion®, vCenter® and vSphere® are registered trademarks or trademarks of VMware, Inc. in the United States or other countries. IBM® is a registered trademark of International Business Machines Corporation. Broadcom® and NetXtreme® are registered trademarks of Broadcom Corporation. QLogic is a registered trademark of QLogic Corporation. Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and/or names or their products and are the property of their respective owners. Dell disclaims proprietary interest in the marks and names of others. 3 Dell Wyse Datacenter for VMware Horizon View Reference Architecture | v.6.7 Table of contents Revisions ............................................................................................................................................................................................. 2 1 Introduction ................................................................................................................................................................................ 9 1.1 Purpose of this document ............................................................................................................................................. 9 1.2 Scope ................................................................................................................................................................................ 9 1.3 New in this release .......................................................................................................................................................... 9 2 Solution architecture overview ............................................................................................................................................. 10 2.1 Introduction ................................................................................................................................................................... 10 2.1.1 Physical architecture overview .................................................................................................................................... 11 2.1.2 Dell Wyse Datacenter – solution layers .................................................................................................................... 12 2.2 Local Tier 1 ..................................................................................................................................................................... 13 2.2.1 Local Tier 1 – 50 user combined pilot ...................................................................................................................... 13 2.2.2 Local Tier 1 – 50 user scale-ready pilot.................................................................................................................... 13 2.2.3 Local Tier 1 (iSCSI) ......................................................................................................................................................... 14 2.3 Shared Tier 1 – Rack ..................................................................................................................................................... 17 2.3.1 Shared Tier 1 – Rack – 555 users (iSCSI) .................................................................................................................. 17 2.3.2 Shared Tier 1 – Rack (iSCSI – EQL) ............................................................................................................................ 18 2.3.3 Shared Tier 1 – Rack – 1000 users (FC – CML) ...................................................................................................... 21 2.4 Shared Tier 1 – Blade ................................................................................................................................................... 24 2.4.1 Shared Tier 1 – Blade – 555 users (iSCSI – EQL) .................................................................................................... 24 2.4.2 Shared Tier 1 – Blade (iSCSI – EQL) .......................................................................................................................... 25 2.4.3 Shared Tier 1 – Blade (FC – CML) .............................................................................................................................. 28 3 Hardware components ........................................................................................................................................................... 31 3.1 Networking ..................................................................................................................................................................... 31 3.1.1 Force10 S55 (ToR switch) ............................................................................................................................................ 31 3.1.2 Force10 S60 (1Gb ToR switch) ................................................................................................................................... 32 3.1.3 Force10 S4810 (10Gb ToR switch) ............................................................................................................................. 33 3.1.4 Brocade 6510 (FC ToR switch) ................................................................................................................................... 35 3.1.5 PowerEdge M I/O Aggregator (10Gb blade interconnect) .................................................................................... 36 3.1.6 PowerConnect M6348 (1Gb blade interconnect) ................................................................................................... 36 3.1.7 Brocade M5424 (FC blade interconnect) ................................................................................................................. 37 3.2 Servers ............................................................................................................................................................................. 38 4 Dell Wyse Datacenter for VMware Horizon View Reference Architecture | v.6.7 3.2.1 PowerEdge R730 ........................................................................................................................................................... 38 3.2.2 PowerEdge M620.......................................................................................................................................................... 38 3.3 Storage

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    121 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us