Manual Serial Prefixed: 134­ ~~Nual Printed: 2/62

Manual Serial Prefixed: 134­ ~~Nual Printed: 2/62

HP Archive This vintage Hewlett Packard document was preserved and distributed by www. hparchive.com Please visit us on the web ! On-line curator: Dale H. Cook OPERATING AND SERVICE MANUAL MODEL 412A/AR SERIALS PREFIXED: 13.4- DC VACUUM TUBE VOLTMETER Cepyritlhl HEWLElf.'''CKAID COM' ANY 1961 1$01 'AOt MILL lOAD, 'ALO AHO, CAlifOINIA, U.S.A. 00129·2 Printed: JAN 1962 Model412A Section I Table I-I Table I-I. Specifications VOLTMETER Voltages and Currents: Voltage Range: ~en Circuit Short Circuit Positive and negative voltages from I millivolt RanS.!' Volts Current full scale to 1000 volts full scale in 13 ranges xl 10 mv 10 ma xl0 100 mv 10 ma Accuracy: xlOO 1 v 10 ma ",1%of full scale on any range xl000 1 v 1 ma xl0K 1 v 100 ua Input Resistance: xl00K 1 v 10 ua 10 megohms ,,1% on Imv, 3mv, and 10mv ranges xlM 1 v lua 30 megohms ,,1% on 30 mv range xl0M 1 v .1 ua 100 megohms ,,1% on 100mv range xlOOM 1 v .01 ua 200 megohms :1% on 300mv range and above AMPLIFIER AC Rejection: Voltage Gain: 1000 maximum A voltage at power line or twice power line fre­ quency 40 db greater than full scale affects AC Rejection: reading less than 1%. Peak voltage must not 3 db at 1 cps, approximately 80 db at 50 and exceed 1500 volts. 60 cps Oulput: AMMETER Proportional to meter indication; 1 volt at full Current Range: scale; maximum current, 1 mao (Full scale Positive and negative currents from 1 micro­ corresponds to 1. 0 on upper scale.) ampere full scale to 1 ampere full scale in thirteen ranges Oulput Impedance: Less than 2 ohms at de Accuracy: ,,2% of full scale on any range Noise: Less than 0.1% of full scale on any range Input Resistance: Drift: negligible Internal Shunt Full Scale Range Resistance- Voltage Drop GENERAL Isotation Resistance: .001 ma 1000 ohms 1 mv At least 100 megohms shunted by 0.1 uf be­ .003 rna 316 ohms 0.9486 mv .01 ma 100 ohms 1 mv tween common terminal and case (power line) ground .03 ma 31. 6 ohms 0.9486 mv .1 ma 10 ohms 1 mv Common Mode Rejection: .3 ma 31. 6 ohms 0.9486 mv May be operated up to 500 vdc or 130 vac from 1 rna 1 ohm 1 mv ground 3 rna .316 ohm 0.9486 mv 10 rna .1 ohm 1 mv Power: 115/230v ±1%, 50-60 cps, 35 W 30 rna .1 ohm 3 mv Dimensions: lOa rna .1 ohm 10 mv Cabinet Mount: 11-1/2 in. high, 7-1/2 in.Wide, 300 ma .1 ohm 30 mv 10 in. deep 1000 rna .1 ohm 100 mv Rack Mount: 'For total insertion resistance add O. 07 ohms copper lead resistance at 250C OHMMETER He sistance Range: Resistance from 1 ohm center-scale to 100­ megohms center-scale in nine decade ranges 0=0 U&II 000 Accuracy: ",5% of reading from 0.2 ohm to 500 megohms " "'10% of reading from 0.1 to 0.2 ohm and from Weight: Cabinet Mount: Net12lbs, shipping 17lbs 500 megohms to 5000 megohms. Rack Mount: Net12 lbs, shipping20 lbs 1-0 00129-2 Model412A Section I Paragraphs 1-1 to 1-10 SECTION I GENERAL DESCRIPTION I-I. GENERAL. the time of the change, replace the line fuse. A one­ hall ampere slow-blow fuse should be used for 115­ 1-2. TheModeI412A/AR DC Vacuum TubeVoltmeter volt q>eration; a 0.4 ampere slow-blow fuse should be is a precision, wide range, multipurpose instrument used for 230-volt q>eration. which covers the entire range of de voltage, current, and resistance measurements normally encountered CAUTION in electronic equipment. Be sure the 115/230 V switch Is set at the 1-3. It measures de voltages over the wide range of proper position before applying power to the 0.02 millivolts to 1000 volts on thirteen ranges ar­ instrument. Incorrect setting of the switch ranged in a 1, 3, 10 sequence from 1 mv full scale to can result in damage to the instrument. 1000 v lull scale. Overall accuracy on all thirteen ranges iswithin ±1%of full scale. Voltage differences can be measured easily since the input circuit is iso­ lated from the case and from the power line ground. 1-4. DAMAGE IN SHIPMENT. 1-5. Inspect and operate this instrument upon re­ ceipt. Section IV includes a performance check which is a good test as part of incoming quality contr.ol in­ spection. The check can be made with the instrument in its cabinet. If there is any damage, see the "Claim Cor Damage in Shipment" paragraph at the back oC this manual. 1-6. POWER CABLE. 1-7. The three-conductor power cable supplied with this instrument terminates ina polarized three-prong male connector recommended by the National Elec­ trical Manufacturers' Association. The third contact is an offset round pin added to a standard two-blade connector. This contact grounds the instrument when used with an appropriate receptacle. An adapter should be used to connect the NEMA plug to a standard two­ contact output. When the adapter is used, the ground connection becomes a short lead from the adapter. This lead should be connected to a suitable ground lor the protection oC Oflerating personnel. 1-8. 115-230 VOLT OPERATION. 1-9. A switch located on the instrument rear converts the Model 412A1AR for use from either a liS-volt or 230-volt, 50-60 cps power source. The switch changes the connection ol lhe dual liS-volt primary windings of the power transformer Cram a parallel combination to a series combination, or vice versa. Switch posi­ tions are marked 115 and 230. 1-10. To convert the instrument from 115-volt opera­ tion to 230-volt operation, or vice versa, insert a screwdriver blade into the switch slot and slide the slot until the marking indicates the line voltage. At Figure 1-1. Model 412A1AR 00129-2 I-I SectJonll Model 412A Table 2-1 Table 2-1. Resistance Range vs ~en-CirCUitVolts/Short-CirCUit Current ~en Circuit Volts Short Circuit Current Range (1. 0 on upper voltage scale) (0 on upper voltage scale) Xl 10 mv 10 ma XI0 100 mv 10 rna • XI00 1 v 10 ma XI000 1 v 1 ma XI0K 1 v 100 ua XI00K 1 v 10 ua XIM Iv lua Xl0M 1 v 0.1 ua XI00M 1 v 0.01 ua 2-0 00129-2 Model412A Section II Paragraphs 2-1 to 2-12 SECTION II OPERATING INSTRUCTIONS 2-1. LOW-LEVEL ELECTRICAL PHENOMENA. c. De-energize circuit to be tested. 2-2. stray low-level electrical phenomena are pre­ d. UseMA/OHMSandCOM leads toconnectinstru­ sent in one form or another, in nearly all electrical ment into circuit. circuits. The 412A does notdistinguish between stray and signal voltages; it measures net voltage. Thus, e. Energize circuit, set POLARITY switch for when using the lower voltage ranges, consider the possibility of low-level electrical phenomena. Ther­ upscale reacting, and read current. mocouples (thermoelectric effect), flexing of coaxial Note cables (trlboelectric effect), apparent residual charges on capacitors (dielectric absorption), battery action When measuring current, be sure there is of two terminals mounted on an imperfect insulator no connection between the chassis-ground. (galvanic action) all can produce voltages within the and cabinet-ground terminals of the DC AMP­ range of the 412A. LIFIER OUTPUT connector. 2-3. The 412A voltage probe, current/resistance lead and common lead are designed to have a very 2-9. RESISTANCE MEASUREMENT. low thermoelectric effect with copper, the most com­ plete electrical conductor. However, you may en­ a. Set FUNCTION selector to OHMS. counter other materials. For example, the leads of many transistors are made of a mixture of iron, nickel b. De-energize circuit to be measured. and cobalt known commercially as Kovar. Fernico, etc. This material makes very good thermocouple S c. Use MA/OHMS and COM leads to connect in­ with copper: about 40 uv/ C with respect to a ref­ strument across circuit or component. erence junction. 2-4. Whenever possible, connect the 412A leads to d. Select rangewhichbrlngs meterpointer as close copper and malntato the points of connection at the as possible to midscale, and read resistance. same temperature, preferably ambient temperature. With the leads so connected, any voltage indicated by the 412A is developed within the circuit under test. 2-10. When measuring the resistance of non-linear devices such as crystal diodes or transistors, you may want to know the voltage applied to the device 2- 5. OPERATING INSTRUCTIONS. and!or the current through it at the time of measure­ ment. By using table 2-1 and the upper voltage scale CAUTION on the meterface, you can determine both. The meter reading is directly proportional to the voltage across Do not overload the instrument. Amplifier the device being measured, and the meter reading input, current shunts, and internal resistance subtracted from full scale is directly proportional to standards are not protected from extreme the current. For example, on the XlO range the upper overload. Momentary overloads ten times voltage scale is aO-IOO mv scale and a 10-0 ma scale. full scale will not damage the instrument. I! the meter Indicates .25 on the resistance scale, the device beingmeasured has anequivalent resistance 2-6. Turn the Model 412A on and allow a few minutes of 2. 5 ohms.

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    32 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us