FINAL New & Renewable Energy Development Corporation of Andhra Pradesh Ltd., (A State Govt. Company- ISO 9001 :2015 Certified) (Formerly Non-Conventional Energy Development Corporation of Andhra Pradesh Ltd.,) Project Location: Chitravathi Project Location: Somasila Taluk: Tadimarri Taluk: Atmakur District: Anantapur District: Nellore Latitude: 14.56 Latitude: 14.487 Longitude: 77.95 Longitude: 79.303 PROJECTPROJECT REPORT REPORT SERIA SERIALL NO: NO: P4/23P3/23-ON-ON-4-3 TECHNO-COMMERCIAL FEASIBILITY REPORT LOCATION: SOMASILA CONSULTANT: WAPCOS LIMITED WAPCOS Ltd., 76-C, Institutional Area, Sector-18, Gurugram, Haryana, India Pin: 122015 MAY 2020 E-mail: [email protected] Preparation of Techno-commercial Feasibility Reports for Pumped Storage Projects at 23 sites in Andhra Pradesh -Somasila Pumped Storage Project (1200 MW) LIST OF THE PROJECT SITES (23 Nos.) I. ON RIVER PROJECT SITES: Project Code Location Taluk District Latitude Longitude P1/23-ON-1 Gandikota Gandikota Kadapa 14.807928 78.251503 P2/23-ON-2 Owk Reservoir Jammalmadugu Kurnool 15.185044 78.085161 P3/23-ON-3 Somasila Atmakur Nellore 14.487423 79.303349 P4/23-ON-4 Chitravathi Tadimarri Anantapur 14.561015 77.958636 II. OFF RIVER PROJECT SITES: Project Code Location Taluk District Latitude Longitude P5/23-OFF-1 Baddumasingi Palakonda Srikakulam 18.7069 83.7264 P6/23-OFF-2 Lambasingi Chintapalli Vishakapatnam 17.8564 82.4658 P7/23-OFF-3 Yerravaram Atchutapuram Vishakapatnam 17.7661 82.4564 P8/23-OFF-4 Gathapanuku Paderu Vishakapatnam 17.9681 82.7611 P9/23-OFF-5 Kadapayapalle Siddhavattam Kadapa 14.5997 78.9439 P10/23-OFF-6 Vongimalla Veeraballi Kadapa 14.2431 78.8783 P11/23-OFF-7 Chintarajupalle Vontimiita Kadapa 14.315 78.9233 P12/23-OFF-8 Duggeru Makkuva Vizianagaram 18.7506 83.1122 P13/23-OFF-9 Peda Rabha Ananthagiri Vishakapatnam 18.2314 83.0406 P14/23-OFF-10 Chittamvalasa Ananthagiri Vishakapatnam 18.2294 82.9083 P15/23-OFF-11 Pedakota Ananthagiri Vishakapatnam 18.1019 82.8756 P16/23-OFF-12 Sirijam Cheedikada Vishakapatnam 18.0647 82.8264 P17/23-OFF-13 Varukaru Paderu Vishakapatnam 18.0539 82.6958 P18/23-OFF-14 Tatiparthi Madugula Vishakapatnam 17.9417 82.6589 P19/23-OFF-15 Z Kothapatnam Ravikantham Vishakapatnam 17.8861 82.5869 P20/23-OFF-16 Chimalabayalu Chintapalle Vishakapatnam 18.0575 82.4725 P21/23-OFF-17 Palamamidi G Madugula Vishakapatnam 17.9647 82.5581 P22/23-OFF-18 Thotaluru Koyyuru Vishakapatnam 17.7992 82.3172 P23/23-OFF-19 Krishnadevipeta Golukonda Vishakapatnam 17.7567 82.2781 WAPCOS LIMITED 1 Preparation of Techno-commercial Feasibility Reports for Pumped Storage Projects at 23 sites in Andhra Pradesh -Somasila Pumped Storage Project (1200 MW) Techno-commercial Feasibility Reports for Pumped Storage Project at Somasila site in Nellore district of Andhra Pradesh New & Renewable Energy Development Corporation of Prepared for Andhra Pradesh Ltd., Represented by VC & Managing Director, NREDCAP CONSULTANT TEAM Team Leader & Pumped Storage Expert Mr. Amitabh Tripathi, Power Planning Expert Mr. Gaurav Kumar Design Expert Mr. Mehak Jeet Singh Deol Electro-Mechanical expert Mr. B.N. Sarkar Hydrology Expert Mr. D.K. Kaushik Geologist Mr. P.Mishra Cost Estimates Expert Mr. Swatantra Kumar Sr. Project Engineer Mr. Rajeev Singh Project Engineer Mr. Ashfaq Ahmad Khan Project Engineer Ms Shashi Tapsi Project Engineer Mr. Chetan Project Engineer Mr. Vinay Shankar Project Site Engineer Mr. Kiran Kumar Project Code H- 3772 Approval Date 20th December 2019 Classification Confidential WAPCOS LIMITED 2 Preparation of Techno-commercial Feasibility Reports for Pumped Storage Projects at 23 sites in Andhra Pradesh -Somasila Pumped Storage Project (1200 MW) TABLE OF CONTENTS WAPCOS LIMITED 3 Preparation of Techno-commercial Feasibility Reports for Pumped Storage Projects at 23 sites in Andhra Pradesh -Somasila Pumped Storage Project (1200 MW) CONTENTS CHAPTER – 1 ......................................................................................................................................... 11 1. EXECUTIVE SUMMARY .................................................................................................................. 11 1.1 Introduction ............................................................................................................................. 11 1.2 Project Background .................................................................................................................. 12 1.3 Project Location ....................................................................................................................... 13 1.4 Access to the Project ................................................................................................................ 13 1.5 Scope of Work ......................................................................................................................... 14 1.6 Topography & Climate .............................................................................................................. 14 1.7 Geology .................................................................................................................................. 15 1.8 Seismicity of the Project Area .................................................................................................... 15 1.9 Installed Capacity and Power Generation ................................................................................... 15 1.10 Land Requirement .................................................................................................................... 16 1.11 Power Evacuation Arrangement: ............................................................................................... 16 1.12 Estimates of the Cost ............................................................................................................... 17 1.13 Financial Aspects ..................................................................................................................... 17 1.14 Conclusion & Recommendation ................................................................................................. 17 1.15 Salient Features ....................................................................................................................... 18 CHAPTER- 2 ........................................................................................................................................... 22 2. ECONOMIC SCENE OF ANDHRA PRADESH ................................................................................... 22 2.1 Introduction ............................................................................................................................. 22 2.2 Economic Parameters .............................................................................................................. 23 2.2.1 GSDP/NSDP ....................................................................................................................... 23 2.2.2 Foreign Direct Investment (FDI) inflow & Investments .............................................................. 23 2.3 Agriculture ............................................................................................................................... 24 2.4 Horticulture .............................................................................................................................. 24 2.5 Irrigation .................................................................................................................................. 25 2.6 Forest Resources ..................................................................................................................... 25 2.7 Fisheries ................................................................................................................................. 26 2.8 Industry ................................................................................................................................... 26 2.9 Information Technology ............................................................................................................ 27 2.10 Service Sector ......................................................................................................................... 27 2.11 Power ..................................................................................................................................... 28 WAPCOS LIMITED 4 Preparation of Techno-commercial Feasibility Reports for Pumped Storage Projects at 23 sites in Andhra Pradesh -Somasila Pumped Storage Project (1200 MW) CHAPTER - 3 .......................................................................................................................................... 31 3. POWER SCENARIO ........................................................................................................................ 31 3.1 Introduction ............................................................................................................................. 31 3.2 Installed Generating Capacity in India ........................................................................................ 33 3.2.1 Advance National Transmission Plan for Year 2021-22 ............................................................ 36 3.2.2 Generation Addition up to 2021-22 ......................................................................................... 36 3.2.3 All India Electrical Energy Requirement, Peak Electricity Demand & Electrical Energy Consumption Projections for 2016-17 to 2026-27 ...................................................................................................
Details
-
File Typepdf
-
Upload Time-
-
Content LanguagesEnglish
-
Upload UserAnonymous/Not logged-in
-
File Pages158 Page
-
File Size-