Test Report Form Template

Test Report Form Template

CE REPORT Report No.: DEU(19)-12-H1038S CE LVD REPORT Product: Air Conditioner PMDW-09AC, PMDW-12AC, PMDW-18AC, PMDW-24AC, PMDW-30AC, PMDW-36AC, PMDW-09ACH, PMDW-12ACH, PMDW-18ACH, PMDW- 24ACH, PMDW-30ACH, PMDW-36ACH PMDW-09BC, PMDW-12BC, Model No.: PMDW-18BC, PMDW-24BC PMDW-09BCH, PMDW-12BCH, PMDW- 18BCH, PMDW-24BCH PMDC-18KS, PMDC-24KS, PMDC-30KS, PMDC- 36KS, PMDC-42KS, PMDC-48KS, PMDC-60KS Trade Mark: Aquamind Applicant : Puremind Technology Co.,Ltd Zhuhai No.302C,3rd Floor,Building No.2,No.1of Science and Technology 7th Add : Rd.,Tangjiawan Town,Xiangzhou District,Zhuhai City,Guangdong Province,china Manufacturer: Puremind Technology Co.,Ltd Zhuhai No.302C,3rd Floor,Building No.2,No.1of Science and Technology 7th Add : Rd.,Tangjiawan Town,Xiangzhou District,Zhuhai City,Guangdong Province,china Issued by : DEU Technology Testing Co.,ltd. Floor 6, West Tower, No.11-1, Creative Industry Park,Haizhu District, Add : Guangzhou, Guangdong, China EN 60335-1:2012+A11:2014 Applicable standards: EN 60335-2-40:2003+A1:2012 Tel : 400-686-9618 Report number : DEU(19)-12-H1038S Date of report : 2019-12-30 Test result : PASS Tested By: Date: 2019-12-30 Approved By: Date: 2019-12-30 Guangzhou Deu Technology Testing Co.,Ltd. Floor 6, West tower, No.11-1,Creative Industry park Haizhu district, Guangzhou,Guangdong, China Page 1 of 93 CE REPORT Report No.: DEU(19)-12-H1038S TEST REPORT EN 60335-1: Safety of household and similar electrical appliances EN 60335-2-40:Safety of household and similar electrical appliances Electrical heat pumps, air- conditioners and dehumidifiers Report Report reference No…………...: DEU(19)-12-H1038S Tested by ……………………...: Mandy Huang (signature) Approved by …………………...: Louis Lau (signature) Date of issue…………………..: 2019-12-30 Testing Laboratory Name ................................................ : Guangzhou Deu Technology Testing Co.,Ltd. Address ............................................ : Floor 6, West tower, No.11-1,Creative Industry park Haizhu district, Guangzhou,Guangdong, China Testing location ................................ : As above Applicant .......................................... : Puremind Technology Co.,Ltd Zhuhai Address ............................................ : No.302C,3rd Floor,Building No.2,No.1of Science and Technology 7th Rd.,Tangjiawan Town,Xiangzhou District,Zhuhai City,Guangdong Province,china Test specification: Standard ........................................... : EN 60335-1:2012+A11:2014 EN 60335-2-40:2003+A1:2012 Test procedure ................................. : LVD Description ....................................... : Air Conditioner Trade Mark ....................................... : Aquamind Model and/or type reference ............ : PMDW-09AC, PMDW-12AC, PMDW-18AC, PMDW-24AC, PMDW-30AC, PMDW-36AC, PMDW-09ACH, PMDW-12ACH, PMDW-18ACH, PMDW-24ACH, PMDW-30ACH, PMDW- 36ACH PMDW-09BC, PMDW-12BC, PMDW-18BC, PMDW- 24BC PMDW-09BCH, PMDW-12BCH, PMDW-18BCH, PMDW- 24BCH PMDC-18KS, PMDC-24KS, PMDC-30KS, PMDC- 36KS, PMDC-42KS, PMDC-48KS, PMDC-60KS Manufacturer ................................... : Puremind Technology Co.,Ltd Zhuhai Address ………………………………: No.302C,3rd Floor,Building No.2,No.1of Science and Technology 7th Rd.,Tangjiawan Town,Xiangzhou District,Zhuhai City,Guangdong Province,china Rating(s) ........................................... : 220-240V, 50-60 Hz Test item particulars Classification of installation and use : Class I Guangzhou Deu Technology Testing Co.,Ltd. Floor 6, West tower, No.11-1,Creative Industry park Haizhu district, Guangzhou,Guangdong, China Page 2 of 93 CE REPORT Report No.: DEU(19)-12-H1038S Possible test case verdicts - test case does not apply to the test object: N/A - test object does meet the requirement: P(Pass) - test object does not meet the requirement: F(Fail) General remarks This test report shall not be reproduced except in full without the written approval of the testing laboratory. The test results presented in this report relate only to the item tested. "(see remark #)" refers to a remark appended to the report. "(see appended table)" refers to a table appended to the report. Air Conditioner Model: PMDW-09AC INPUT: 220-240V, 50-60 Hz Puremind Technology Co.,Ltd Zhuhai No.302C,3rd Floor,Building No.2,No.1of Science and Technology 7th Rd.,Tangjiawan Town,Xiangzhou District,Zhuhai City,Guangdong Province,china 5 GENERAL CONDITIONS FOR THE TESTS -- Tests performed according to cl. 5, e.g. nature of P supply, sequence of testing, etc. Guangzhou Deu Technology Testing Co.,Ltd. Floor 6, West tower, No.11-1,Creative Industry park Haizhu district, Guangzhou,Guangdong, China Page 3 of 93 CE REPORT Report No.: DEU(19)-12-H1038S EN 60335-1 Clause Requirement - Test Result - Remark Verdict 6 CLASSIFICATION -- 6.1 Protection against electric shock: Class I P Class I, II, III ............................................................ : 6.2 Protection against harmful ingress of water N 7 MARKING AND INSTRUCTIONS -- 7.1 Rated voltage or voltage range (V) ......................... : 220-240V~ P Single-phase appliances to be connected to the N supply mains: 230 V covered Multi-phase appliances to be connected to the N supply mains: 400 V covered Nature of supply ....................................................... : ~ P Rated frequency (Hz) ............................................... : 50-60Hz P Rated power input (W) ............................................. : P Rated current (A) .................................................... : P Manufacturer's or responsible vendor's name, See page 2 P trademark or identification mark .............................. : Model or type reference ........................................... : See page 2 P Symbol 5172 of EN 60417, for Class II appliances N IP number, other than IPX0 ..................................... : P Symbol EN 60417-5036, for the enclosure of N electrically-operated water valves in external hose- sets for connection of an appliance to the water mains 7.2 Warning for stationary appliances for multiple supply N Warning placed in vicinity of terminal cover N 7.3 Range of rated values marked with the lower and P upper limits separated by a hyphen Guangzhou Deu Technology Testing Co.,Ltd. Floor 6, West tower, No.11-1,Creative Industry park Haizhu district, Guangzhou,Guangdong, China Page 4 of 93 CE REPORT Report No.: DEU(19)-12-H1038S EN 60335-1 Clause Requirement - Test Result - Remark Verdict Different rated values marked with the values N separated by an oblique stroke 7.4 Appliances adjustable for different rated voltages, N the voltage setting is clearly discernible 7.5 Appliances with more than one rated voltage or one N or more rated voltage ranges, marked with rated input or rated current for each rated voltage or range, unless the power input is related to the mean value of the P rated voltage range Relation between marking for upper and lower limits N of rated power input or rated current and voltage is clear 7.6 Correct symbols used P 7.7 Connection diagram fixed to appliances to be N connected to more than two supply conductors and appliances for multiple supply 7.8 Except for type Z attachment, terminals for connection to the supply mains indicated N as follows: - marking of terminals exclusively for the neutral N conductor (N) - marking of protective earthing terminals (symbol N 5019 of EN 60417) - marking not placed on removable parts N 7.9 Marking or placing of switches which may cause a N hazard 7.10 Indications of switches on stationary appliances and P controls on all appliances by use of figures, letters or other visual means ................................................... : The figure 0 indicates only OFF position, unless no N confusion with the OFF position Guangzhou Deu Technology Testing Co.,Ltd. Floor 6, West tower, No.11-1,Creative Industry park Haizhu district, Guangzhou,Guangdong, China Page 5 of 93 CE REPORT Report No.: DEU(19)-12-H1038S EN 60335-1 Clause Requirement - Test Result - Remark Verdict 7.11 Indication for direction of adjustment of controls N 7.12 Instructions for safe use provided P 7.12.1 Sufficient details for installation supplied P 7.12.2 Stationary appliances not fitted with means for N disconnection from the supply mains having a contact separation in all poles that provide full disconnection under overvoltage category III, the instructions state that means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules 7.12.3 Insulation of the fixed wiring in contact with parts N exceeding 50 K during clause 11; instructions stating that the fixed wiring must be protected 7.12.4 Instructions for built-in appliances: N - dimensions of space N - dimensions and position of supporting means N - distances between parts and surrounding structure N - dimensions of ventilation openings and N arrangement - connection to supply mains and interconnection of N separate components - allow disconnection of the appliance after N installation, by accessible plug or a switch in the fixed wiring, unless a switch complying with 24.3 N 7.12.5 Replacement cord instructions, type X attachment N with a specially prepared cord Replacement cord instructions, type Y attachment P Replacement cord instructions, type Z attachment N 7.12.6 Caution in the instructions for heating appliances N with a non-self-resetting thermal cut-out 7.12.7 Instructions for fixed appliances stating how the N appliance is to be fixed 7.12.8 Instructions for appliances connected to the water mains: N - max. inlet water pressure (Pa) .............................

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    93 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us