Rutherford Scattering of Α-Particles

Rutherford Scattering of Α-Particles

Rutherford Scattering of α-Particles Emily P. Wang∗ MIT Department of Physics (Dated: December 8, 2004) The scattering of α-particles off of gold foil was investigated. Attenuation of the α-particle beam was used to measure the thickness of the gold foil used. The coefficient of the Rutherford differential scattering cross section was experimentally determined to be (7.81 ± 5.35) × 10−25cm2, compared to 1.76 × 10−24cm2, with a reduced chi-squared of 3.4, which is a reasonable fit and confirms the accuracy of the Rutherford model of the atom. 1. INTRODUCTION 2. DIFFERENTIAL SCATTERING CROSS SECTION OF NUCLEI When Geiger and Marsden first began scattering ex- For a single scatterer, such as a single gold nucleus periments involving alpha particles and thin metal foils, within a thin gold foil layer, the differential scattering scientists knew little about the structure of the atom. cross section is defined as follows [2]: The charge to mass ratio of the electron was known with reasonable accuracy, and it was also known that most of dσ(θ, φ) flux scattered into element dΩ at angles (θ, φ) = the mass in an atom was due to the positive charge. The dΩ incident flux per unit area dilemma faced by scientists was understanding how the positive and negative components of the atom were held where σ is the scattering cross section of a single nucleus. together, and how they managed to create the regular To obtain the differential scattering cross section, one can phenomena that had been observed, such as the combi- make measurements of the intensity Iθ of the beam when nation rules and series limits for the complex spectra of alpha particles are scattered through certain angles θ and multi-electron atoms. calculate as follows: dσ I × A Drawing upon Newtonian mechanics and Maxwell’s = θ (1) electromagnetic theory, J. J. Thompson formulated the dΩ dΩ × I0 × NAvo × ρ × xfoil “plum-pudding” model of the atom. In this model, where N is Avogadro’s number, x is the thickness the atom consisted of a spherical “pudding” of positive Avo foil of the target foil, A is the atomic mass of the material in charge, and electrons were distributed throughout the the target foil, dΩ is the solid-angle of the detector, I is atom, much like raisins in a pudding. The drawbacks of 0 the unattenuated intensity of the alpha particle beam. the plum-pudding model was that it yielded no explana- Using classical mechanics to calculate the effect on al- tion for the quantized nature of the hydrogen spectrum, pha particles as they approached atomic nuclei, Ruther- as expressed by the Balmer formula and the Ritz combi- ford derived an equation to describe the scattering of nation principle for atomic spectra. particles at large angles, where scattering is mostly due Rutherford came upon the idea of probing the struc- to a single scattering event rather than multiple small an- ture of atom by firing α-particles, or helium ions, at thin gle scattering events. Laborious experiments conducted metal foils. The experiments conducted by Rutherford by Geiger and Marsden found this equation to hold true. and his collaborators Geiger and Marsden lead to a rev- The equation is as follows [3]: olution in the model of atomic structure. If, the plum- pudding model had indeed been correct, then the fraction dσ ZZ0e2 1 of particles scattered through an angle of θ or greater = ( )2 (2) dΩ 4E sin4( θ ) should have been observed to fall off like a Gaussian. 2 This description was found to be accurate for small an- where Ze is the charge of the target nuclei, Z0e is the gle scattering, but not for large angles of scattering [1]. charge of the alpha particles, and E is the kinetic energy The goal of this experiment was to reproduce Ruther- of the alpha particles. ford’s experiment with thin metal foils by scattering al- pha particles through a gold foil. Experimental data was compared to the theoretical model of Rutherford scatter- 3. SOLID-STATE DETECTORS ing. Solid-state dectectors hold several advantages over their gas-filled counterparts. One advantage is the greater resolution and better statistics possible, due to ∗Electronic address: [email protected] the fact that lower energy is needed for the creation of 2 n-p Junction (with Bias Voltage) Solid-State Detector Preamplifier Voltage Limiter Oscilloscope Bias Voltage θ Amplifier Vacuum High Voltage Electrons chamber Holes Target foils Alpha-particle Multi-Channel source Analyzer 241 Am Depletion Zones # holes n p n p FIG. 2: Setup of equipment used for both open-aperture and attenuated beam measurements, as well as angular depen- dence of differential scattering cross section. The vacuum # electrons chamber was maintained at approximately 200 microns, or −3 FIG. 1: The upper two images show an n-p semi-conductor 10 torr junction before and after bias voltage is turned on. The lower two images show the depletion zone in each case–note that the depletion zone length is increased with the addition of vacuum chamber with a clear plexiglass cover weighted bias voltage. Figure adapted from [4] down with lead bricks (in order to ensure the o-ring along the rim of the vacuum chamber achieved a good seal). With the bias voltage on the silicon barrier de- electron-ion pairs. Another advantage is the greater stop- tector turned down, the air was then pumped out of the ping power of the solid-state detector, which allows the cylindrical vacuum chamber. After the pressure in the detection of particles with energies characteristic of nu- chamber was on the order of 200 microns, the lead bricks clear interactions [4]. As the alpha particle beam was were removed from the plexiglass cover and a thick black to be interacting with the nuclei of atoms in this exper- cloth sheath was placed over the vacuum chamber. The iment, a silicon barrier detector, one type of solid-state bias voltage of the system was then slowly turned up to detector, was used for counting purposes. approximately +52V. To protect the detector, the cloth For the best results, semi-conductor junctions are used cover was placed over the vacuum chamber whenever the in most solid-state detectors–these detectors are also bias voltage was turned up–it was necessary to turn down known as barrier layer detectors. An n-p semi-conductor the bias voltage whenever adjustments in the alpha par- junction is shown in Figure 1. On the left-hand side of ticle beam source needed to be made. the junction is the n-type semiconductor, which donates The first part of this experiment involved calculating negative charge carriers, or electrons. On the right-hand the thickness of the gold foil targets and characterizing side of the junction is the p-type semiconductor, which the profile of the alpha particle beam. The target foils donates positive charge carriers, or holes. There is an were mounted in a small, flat, rectangular piece of metal area between the n- and p-type materials where there are that contained several holes, some of which had metal neither positive nor negative charge carriers present, and foils secured over them, and some of which were left this area is called the “depletion zone”. It is in this re- open for open-aperture measurements. The rectangu- gion of the detector that the electron-ion pairs are formed lar piece of metal containing the open aperture and the and detected. An alpha particle enters from the n side target foils was placed approximately 8 cm away from of the junction and forms an electron-ion pair in the de- the point where the alpha particles emerged from the pletion zone. Critical to the effectiveness of these barrier source. One experimental consideration was the height detectors is the bias voltage, which serves to increase the of the target foils and open aperture relative to the al- length of the depletion zone. The longer the depletion pha particle beam height–to determine the optimal posi- zone, the greater the fraction of alpha particles that will tion, the countrate was recorded for different heights in be captured and detected. For achieving good resolution 2mm increments, and the vertical positioning with the in the solid-state detector, then, the length of the deple- maximum number of counts was recorded and used in tion zone must be sufficiently large. Once the electron- subsequent measurements. ion pair forms in the depletion zone, the two charges are To measure the beam profile, the height of the target accelerated in opposite directions, and this acceleration foil holder was set for the open aperture, and the beam of charges causes a current that registers in the detector was allowed to impinge upon the detector at angles rang- [4]. ing from -6 degrees to 8 degrees with the normal. The to- tal number of counts over run times ranging from 100 sec- onds (for smaller angles) to 300 seconds (for ±6oand9o) 4. EXPERIMENTAL SETUP AND OBTAINING was determined for each angular position. This was done BEAM PROFILE by noting the MCS spectrum output and summing over all channels of the peak. The countrate was determined The setup for the experiment is shown in Figure 2. In for each angle measurement and was plotted, as shown in conducting the experiment, the first step was to cover the Figure 3. The shape of the beam profile is approximately 3 α−Beam Profile 250 Experimental Data TABLE I: Beam Attenuation Data Target Peak Rangea Thickness −3 2 −3 2 200 (MeV) (10 g/cm ) (10 g/cm ) None 5.486 18.04 N/A 150 Au (4 layers) 3.115 8.787 9.256 ± 0.711 Au (8 layers) 0.791 2.284 15.78 ± 0.439 100 aProjected range of α-particles in Au was obtained from http://physics.nist.gov/PhysRefData/Star/Text/ASTAR.html.

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    5 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us