The Sum and Substance of Skeletal Anchorage System – a Narrative Review

The Sum and Substance of Skeletal Anchorage System – a Narrative Review

wjpmr, 2019,5(9), 57-62 SJIF Impact Factor: 4.639 WORLD JOURNAL OF PHARMACEUTICAL Review Article Ganesh et al. AND MEDICAL RESEARCH World Journal of Pharmaceutical and Medical ResearchISSN 2455 -3301 www.wjpmr.com WJPMR THE SUM AND SUBSTANCE OF SKELETAL ANCHORAGE SYSTEM – A NARRATIVE REVIEW Dr. Gayatri Ganesh1 and Dr. Tulika Tripathi*2 1Senior Resident, Department of Orthodontics & Dentofacial Orthopaedics, Maulana Azad Institute of Dental Sciences, MAMC Complex, Bahadur Shah Zafar Marg, New Delhi-110002, India. 2Senior Professor and Head, Department of Orthodontics & Dentofacial Orthopaedics, Maulana Azad Institute of Dental Sciences, MAMC Complex, Bahadur Shah Zafar Marg, New Delhi-110002, India. *Corresponding Author: Dr. Tulika Tripathi Senior Professor and Head, Department of Orthodontics & Dentofacial Orthopaedics, Maulana Azad Institute of Dental Sciences, MAMC Complex, Bahadur Shah Zafar Marg, New Delhi-110002, India. Article Received on 27/06/2019 Article Revised on 17/07/2019 Article Accepted on 07/08/2019 ABSTRACT The introduction of skeletal anchorage system (SAS) in the field of orthodontics has expanded the spectrum of skeletal correction of malocclusion beyond its existing boundaries. Miniplates have proven to be a reliable, effective and predictable treatment modality. The treatment planning of borderline and severe jaw deformities has become simpler and less invasive with SAS. In addition, now nonsurgical and non extraction treatment options are available for a variety of conditions such as molar distalisation or vertical maxillary excess. This review illustrates the basics of skeletal anchorage system and its versatility in the correction of malocclusion with orthodontic or orthopaedic movement in all three planes of space. The advantages and disadvantages over the conventional mini implants alongwith the scope of biodegradable miniplates in orthodontics has also been discussed. KEYWORDS: Bone Plates, Jaw Abnormality, Malocclusion, Osseointegration. 1. INTRODUCTION The aim of this article is to exemplify the basics of skeletal anchorage and describe its applications in A fundamental requirement of successful treatment of various clinical scenarios. various malocclusions in the field of orthodontics is the presence of secure anchorage. Achieving controlled tooth 1.1 History of Skeletal Anchorage movement without undesirable reciprocal movement of The first possible mention of the skeletal anchorage the anchorage unit during space closure is one of the system was by Creekmore and Eklund in 1983,[2] who prime considerations before treatment commencement. It suggested the use of a vitallium bone screw for intrusion is essential to predetermine the reactive load on the of the maxillary central incisors. Jenner and anchor tooth during active tooth movement. This is based Fitzpatrick.[3] reported the use of a bone plate as an on the force magnitude, type, direction and duration additional orthodontic anchor to retract lower molars. applied on the reciprocal teeth. If the patient’s innate The first use of titanium miniplates and miniscrews in periodontal anchorage potential is unable to [4] orthodontics was described by Sugawara et al, where accommodate for the potential required, additional intra- due to lack of molar anchorage in the lower arch, a oral or extra-oral anchorage devices have to be employed titanium miniplate and a miniscrew was added to correct to prevent any side effects.[1] Over the years, many a severe crossbite. Subsequently in 1998, Sugawara et devices and techniques have been developed by various [5] al, utilized the skeletal anchorage system (SAS) orthodontists to provide the same. comprising of titanium miniplates for Class III correction by lower molar distalization. Sherwood in 2002,[6] stated The traditional auxiliary anchorage devices such as that the intrusion of maxillary molars using miniplates headgear or intermaxillary elastics possess certain resulted in counterclockwise mandibular rotation and disadvantages such as visibility, dependency on patient correction of anterior open bite. Sugawara and compliance and the risk of unwanted side effects. For Nishimura (2005) described the skeletal anchorage example, the use of Class-II elastics can lead to canting system (SAS) as an orthodontic anchorage modality of the occlusal plane in the clockwise direction, extrusion utilizing titanium miniplates and monocortical screws of teeth and protrusion of the maxillary incisors.[1] The temporarily fixed in the maxilla and/or mandible for skeletal anchorage system provides Type A anchorage absolute orthodontic anchorage.[7] Over the years, many which is usually difficult to obtain with the traditional modifications such as the Beneplate system consisting of devices. www.wjpmr.com 57 Ganesh et al. World Journal of Pharmaceutical and Medical Research a 1.2mm-thick stainless steel plate connected to the The miniplates are anchored to the bone by means of the orthodontic appliance with a .045" stainless steel wire monocortical miniscrews. These screws are more have been introduced.[8] vulnerable to failure during the early stages due to the presence of immature interfacial bone. Post insertion, the Thus, skeletal anchorage system is currently quite immediate retention of the plates is entirely based on popular as a system to compensate for malocclusions that bone strength and the design of the screw.[15] Previous cannot be corrected with traditional orthodontics. histological studies have reported increased bone remodeling activity at the screw or implant-bone 2. Disadvantages of Mini implants interface with time.[16,17] It has been demonstrated that Orthodontic miniscrews have a failure rate of 13.5 %. within 1 mm of an implant surface the bone displays a Unlike prosthetic implants, the stability of miniscrews is lower microhardness and a sustained elevated not based on the principle of osseointegration suggested remodeling rate preventing the supporting bone from by Branemark.[9] In contrast, it depends on the fully mineralizing.[18] In addition, higher bone contact mechanical locking of threads into the bony tissues may be achieved with the use of self-drilling screws.[19] which consequently hold up the orthodontic loading.[10] Cortical plate thickness at the site of insertion is also The risk factors associated with the stability of related to the primary stability. The cortical plate miniscrews are general factors like age, tobacco thickness varies from approximately 0.8 to 2.4 mm. At smoking, systemic diseases like diabetes, infective some sites, only a single thread engaged the cortical bone endocarditis or juvenile idiopathic arthritis or local while at some other sites 3 threads of the screw were factors like bone quality, poor oral hygiene, type of engaging the cortical bone, providing for more primary mucosa etc.[11] stability.[15] Many complications witnessed with the use of Post treatment completion, it is desirable that the screws miniscrews over the years have lead the researchers can be easily removed by hand removal with a surgical towards the use of skeletal anchorage systems. Some of driver without the use of trephines. To facilitate easy them include screw fractures due to the effect of removal, the screws are not subjected to pre insertion insertion torque and bone quality at the site of the surface treatments such as sandblasting, etching or insertion and undesired effects like screw loosening and plasma spraying which are usually done to increase the fracture.[12,13] Irreversible damage to the adjacent teeth percentage of bone attachment. As a result, primary and the periodontium have also been reported. Further, stability is important for early survival.[20] screw–root proximity is considered a major risk factor for screw failure as it has the potential to induce pain, 4. Components of SAS infection and root resorption. However, damage to the [12] The disadvantage of using standard miniplates of adjacent soft tissues is often reported to be transient. maxillofacial surgery in orthodontics is that the Rare complications such a nerve injury, air subcutaneous emergence area of these plates is not rounded and they emphysema and maxillary sinus perforation have also [14] have sharp corners causing delayed wound healing and been observed. soft tissue irritation. Emergence point of the plate is defined as the point where the plate arm is exposed or 3. Principle perforating the oral mucosa and is an important Branemark’s principle of osseointegration largely forms consideration during insertion of the miniplate.[19] the basis of skeletal anchorage. Osseointegration is described as the direct contact between living bone and SAS is comprised of bone plates and fixation screws.[4] an implant visible through an optical microscope.[9] 4.1 Bone Plate www.wjpmr.com 58 Ganesh et al. World Journal of Pharmaceutical and Medical Research Fixation Screws protraction of upper molars while the Y shaped plate is The miniplates are fixed on the bone using screws. placed over the buttress to intrude and distalize upper Depending on the diameter of the fixations screws, the molars. Some studies have reported minor perforations in miniplate systems can be classified as the 1.0, 1.5, 2.0 or the sinus membrane with predrilling, which necessarily 2.3 mm systems. The surface areas of higher diameter (2 may not be a concern. Increasing the primary stability of or 2.3 mm) screws are larger and have greater fixation screws in the maxilla has been observed with mechanical strength. With increase in diameter

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    6 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us