A Space-Maintaining Resorbable Membrane for Guided Tissue Regeneration

A Space-Maintaining Resorbable Membrane for Guided Tissue Regeneration

Technology & Services A Space-maintaining Resorbable Membrane for Guided Tissue Regeneration a report by Dr Joey Heinze University of Oklahoma, Department of Periodontology Introduction A membrane that features optimal space maintenance has to be stiff, so that it will not collapse over the The use of guided tissue regeneration techniques to defect it spans. This is particularly true if no graft treat periodontal defects is now commonplace. The materials are used in the defect to support the protocol employs barrier membranes to regenerate membrane mechanically from underneath. If a periodontal ligament, cementum and bone by membrane collapses into the defect space, the excluding the faster growing soft tissue cells from the potentially regenerated volume is reduced and will defect space. Clinical studies have widely not allow optimal clinical outcome. The membrane demonstrated superiority of this treatment modality should be stiff enough to withstand the pressures over traditional open flap debridement techniques.1–2 exerted by the overlying flaps and to withstand external forces like mastication, until the blood clot A variety of membranes are available in the building underneath the membrane has matured marketplace, starting from non-resorbable enough to support it. polytetraflouroethylene (PTFE) membranes to resorbable collagen and polylactide (PLA) This stiffness, on the other hand, would not allow polyglycolic acid (PGA)-based membranes, all of good clinical manageability or ease of use, as a stiff which exhibit satisfactory clinical outcomes.3–5 membrane cannot be contoured easily to a three- dimensional-defect – it would have sharp corners Tatakis et al.6 have referred to a set of design that may perforate the gingival tissues and membrane requirements that need to be met for a periodontal immobilisation could be difficult due to its spring- membrane to be effective. In short, these are back effect. Therefore, there has been a trade-off biocompatibility, cell exclusion, space maintenance, between these criteria to present date. tissue integration, ease of use and biological activity. The failure of a device in one or more of these The second criteria that has not been satisfied by the criteria may be the reason for unsatisfactory membranes of the first generation is that of performance in the regeneration of periodontal biological activity. Some pre-clinical research is defects. Most of the membranes currently available underway in which membranes in combination have incorporated these criteria into their design to with growth factors are evaluated,7–9 with varying degrees. encouraging results. The growth factors are added to accelerate the regeneration of periodontium and Nevertheless, none of the first-generation lead to faster healing. Undoubtedly, the future membranes exhibits a truly optimal design, satisfying belongs to these devices. However, it is yet unclear all the criteria. Two of the design criteria mentioned whether such devices will become available to the have been particularly hard to meet so far. They are end user in the near future, simply because of the space maintenance and biological activity. high cost of growth factors and the fact that these 1. Nyman et al. “New attachment following surgical treatment of human periodontal disease”, J. Clin. Periodontol. (1982). 2. Gottlow J et al. “New attachment formation in the human periodontium by guided tissue regeneration”, Case reports, J. Clin. Periodontol. (1986). 3. Cortellini P et al. “Periodontal regeneration of human infrabony defects with bioresorbable membranes. A controlled clinical trial”, J. Periodontol. (1996). 4. Eickholz P et al. “Periodontal surgery of vertical bony defects with or without synthetical bioabsorbable barriers”, 12 months’ results, J. Periodontol. (1998). 5. Needleman I G et al. “Guided tissue regeneration for periodontal infra-bony defects” (Cochrane Review), The Cochrane Library (2001). 6. Tatakis et al. “Gingival recession treatment: guided tissue regeneration with bioabsorbable membrane versus connective tissue graft”, J. Periodontol. 71: (2000). 1 BUSINESS BRIEFING: GLOBAL SURGERY 2004 Technology & Services Figure 1: Inion GTR™ Biodegradable Membrane in contacts saliva, the membrane turns stiff within Soft Stage minutes. This allows the surgeon to spare the use of a bone grafting material, provided the defect is not too large. There would only be a blood clot in the defect space and that is suggested to provide optimal regeneration conditions10 for periodontal ligament, cementum and bone. This two-stage membrane characteristic is obtained by the use of a plasticising agent, which temporarily softens the membrane matrix and leaches out slowly after the membrane is placed, thus rendering the membrane material stiff again. During the insertion phase the material is soft and a little stretchy or rubbery, but not as weak as collagen materials. This facilitates the safe and precise trimming of the membrane, easy insertion and the formation of a Figure 2: SEM Photograph of the Inion GTR™ good seal between the root of the affected tooth Membrane Surface Structure and the membrane, hindering the intrusion of soft tissue cells into the space. In the soft stage the membrane shows adequate contourability and the shape given is ‘conserved’ when the membrane stiffens up. The stiffening can be accelerated by flushing with sterile water, thus accelerating the release of the plasticiser. Moreover, the rubbery membrane material possesses enough tear strength to be immobilised with sutures. It is easy to form a seal between the root of the affected tooth and the membrane by using a suture sling around the tooth. The pliability of the material helps to strictly appose the membrane to the tooth when pulled tight with the suture. The elimination of a residual gap will help exclude soft tissue cells from the defect and require a lengthy regulatory process before they can therefore increase the success rate. be marketed for a specific clinical application. This is the impetus for devices that exhibit biological Another fast way to immobilise the membrane is to activity without the use of growth factors. use the Inion GTR Biodegradable Tacks. These can be inserted without membrane dislocation Inion Inc., a medical device company specialising in immediately after pilot holes are drilled through the development and manufacture of resorbable the membrane into the bone. The tack kit is implants, has concentrated its periodontal membrane provided with six tacks, a sterile drill and a single- development on closing these design gaps. In the use tack applicator, eliminating any preparatory following section, the new Inion GTR™ work for the physician. Biodegradable Membrane System and how it addresses all design aspects will be discussed. In an in vitro test the membrane was exposed to a watery solution and its tensile strength behaviour was Space Maintenance and Ease of Use measured after different exposure times. After one minute of exposure in the solution, the membrane The idea was to conceptualise a membrane that is shows about double its initial strength, reaching its soft only as long as it needs to be soft, during the ultimate strength after approximately 30 minutes insertion phase. After insertion, when the membrane immersion in water. 7. Takeishi H et al. “Molded bone augmentation by a combination of barrier membrane and recombinant human bone morphogenetic protein-2”, Oral Dis. (Sept. 2001). 8. Danesh-Meyer M J, “Tissue engineering in periodontics and implantology using rhBMP-2”, Ann. R. Australas. Coll. Dent. Surg. (15 Oct. 2000). 9. Sigurdson T J et al. “Periodontal regenerative potential of space-providing expanded polytetrafluoroethylene membranes and recombinant human bone morphogenetic proteins”, J. Periodontol. (June 1995). 2 10. Wikesjö et al. “Significance of early healing events on periodontal repair: a review”, J. Periodontol. (Mar 1992). BUSINESS BRIEFING: GLOBAL SURGERY 2004 A Space-maintaining Resorbable Membrane for Guided Tissue Regeneration Tissue Integration and Figure 3: Defect Covered with GTR (left) and Without (right) Cell Occlusivity One of the prime requirements for guided tissue regeneration barriers is occlusivity. It means that the barrier membrane has to be impermeable for epithelial cells; otherwise, these faster growing cells would populate the wound space and inhibit the regeneration of periodontium. This inhibition of epithelial migration should be provided for the time span the periodontal defect needs to heal (at least). This timespan was researched to be at least four The proprietary compounds and resulting devices weeks6, but as healing depends greatly on a variety of were independently tested according to patient related factors, this duration can be internationally recognised standards and were significantly longer. The Inion GTR membrane found to possess excellent biocompatibility. provides a barrier function of at least eight to 12 Moreover, polymers made from identical building weeks and thus allows sufficient time for regeneration blocks were used safely already for decades in while at the same time allowing re-entry of the site resorbable suture materials, sports medicine devices should this be necessary. After that time period, the and craniofacial implants. membrane starts to disintegrate and resorb gradually. In an in vivo degradation study, membranes were Effective exclusion of epithelial cells will occur if a implanted in the mandibles of sheep and tight seal is formed between the membrane

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    4 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us