Prezentacja Programu Powerpoint

Prezentacja Programu Powerpoint

COMMON DIRECTION #SolarisTalks Michał Sierszyński Advanced Technologies Manager COMMON DIRECTION #SolarisTalks Batteries offered by Solaris NEW SOLARIS SOLARIS SOLARIS HIGH POWER HIGH ENERGY HIGH ENERGY+ High power density High energy density Latest Solaris battery solution Perfect solution for fast charging Solution which is able to provide Very high energy density long range on a single charge Can be fitted in electric buses, A vehicle with HE+ batteries trolleybuses, hydrogen vehicles is able to cover distances up to 200 km* on a single charge *Example for the bus equipped with a hybrid heating COMMON DIRECTION #SolarisTalks New ! battery battery 5 x Pack HE+ 6 x Pack HE Solaris Urbino 12 electric Solaris Urbino 12 electric Range on a single charge: 200 km* Range on a single charge: 150 km* Number of passengers: 69 Number of passengers : 64 With Solaris High Energy+ battery it is possible to obtain both a larger range of the vehicle and a higher passenger capacity *Example by energy consumption of 1,39 kWh/km (hybrid heating) COMMON DIRECTION Solaris High Energy+ in Urbino 18 electric #SolarisTalks 4 x 7 x battery pack roof Solaris High Energy + 200 km range on a single charge* 3 x rear *Example by energy consumption of 1,94 kWh/km (hybrid heating) COMMON DIRECTION Battery #SolarisTalks placement Solaris Urbino 12 electric 1, 5 3, 4 2 Solaris Urbino 18 electric 1, 7 3, 4, 5, 6 2 COMMON DIRECTION #SolarisTalks Let’s talk about the details COMMON DIRECTION Battery #SolarisTalks technology comparison Energy density [Wh/kg] Wide range of traction batteries Charging power Life time density [years] Key [W/kg] Innovative technologies parameters of individual batteries Batteries perfectly suited Weight [kg] to the customer needs Discharging power (the more points the density better) [W/kg] High Power High Energy High Energy + COMMON DIRECTION Battery #SolarisTalks technology comparison SOLARIS SOLARIS Increase of nominal energy of the battery HIGH ENERGY HIGH ENERGY+ on the example of Solaris Urbino 18 electric 600 700 7x 600 Solaris High Energy+ (NMC) 500 500 6x ] KWH [ Solaris High Energy (NMC) 400 400 Solaris High Power (LFP) 5x ENERGY ENERGY 300 NOMINAL 6x 300 4x 200 5x 100 3x 4x 200 0 Nominal 2 0 13 2 0 14 2 0 15 2 0 16 2 0 17 2 0 18 2 0 19 2 0 2 0 2 0 2 1 energy [kWh] COMMON DIRECTION Warranty ≠ life time #SolarisTalks WARRANTY = guaranteed performance e.g. we guarantee that the battery in a period of 5 years or a mileage of no more than 500,000 km will work properly and the energy capacity available to the user will not drop to around 80% of the capacity available to the user with a new battery. LIFE TIME = technical durability of components Information used to plan the battery replacement period. Battery life designed for a given period of time. There is no guarantee that the technical parameters will be preserved, including the capacity. Example: Bus lifetime is equal to 15 years but the warranty is provided up to 3 years COMMON DIRECTION #SolarisTalks Batteries offered by Solaris NEW SOLARIS SOLARIS SOLARIS HIGH POWER HIGH ENERGY HIGH ENERGY+ no limits up to 500 000 km* up to 500 000 km* up to 7 years* up to 5 years* up to 5 years* *The restrictions depend on working conditions. The warranty time is calculated for each case. COMMON DIRECTION Charging possibilities #SolarisTalks BATTERY BUS BATTERY BUS HYRDROGEN BUS (PLUG-IN CHARGING) (PANTOGRAPH CHARGING) High energy density High power density High power density storage system storage system storage system Charging the battery at bus Single refueling: Batteries charged at the depot stops - even in 7 minutes ~10 min. Long distance covered on one Shorter distance, 350 km range on one refueling charge (200 km*) more frequent charging COMMON DIRECTION #SolarisTalks How to choose the optimal battery? COMMON DIRECTION #SolarisTalks How to optimally ?manage the battery bus fleet? How to speed up the diagnosis and prepare ? the appropriate service action? How to check the battery usage during its lifetime to be able to use it in the appropriate ? second life app? COMMON DIRECTION #SolarisTalks Feasibility studies DATA 01. COLLECTING DATA 02. ANALYSIS 03. CALCULATIONS 04. SOLUTION COMMON DIRECTION #SolarisTalks Fleet management – Possibility of supervising the battery COMMON Charging Energy Energy of discharge Energy of recuperation Battery power Battery heating status Many other bus parameters… COMMON DIRECTION #SolarisTalks Stationary energy storage system COMMON DIRECTION #SolarisTalks Any questions?.

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    17 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us