Current Directions in Biomedical Engineering 2018; 4(1): 563 – 565 Daniel Polterauer*, Giacomo Mandruzzato, Maike Neuling, Marek Polak, Joachim Müller, John-Martin Hempel PromBERA: A preoperative eABR: An update Objective promontory stimulation eABR test for measuring the integrity of the auditory nerve in prospective CI candidates. Abstract: Prior to cochlear implantation, audiological https://doi.org/10.1515/cdbme-2018-0135 tests are performed to determine candidacy in subjects with a hearing loss. This is usually done by measuring the acoustic auditory brainstem response (ABR). 1 Introduction Unfortunately, for some subjects, a reproducible ABR recording cannot be obtained, even at high acoustic levels. Promontory Stimulation is a well-established tool to Having a healthy stimulating auditory nerve is stimulate the cochlea preoperatively with a temporary required for cochlear implantation in order to benefit from transtympanic needle placed in the middle ear [1]. It has the electrical pulses that are generated by the implant and been shown that electrically evoked Auditory Brainstem to improve speech comprehension. In some subjects, this Response (eABR) measurements recorded with prerequisite cannot be measured using routine Promontory Stimulation is an useful objective audiological tests. measurement in cochlear implant (CI) candidates for In this study, the feasibility of recording testing and evaluating the presence and excitability of the electrically evoked auditory brainstem responses (eABR) auditory nerve and auditory pathway before cochlear using a stimulating transtympanic electrode, placed on the implantation [2]. This test is especially important for round window niche, together with MED-EL clinical subjects where it is difficult or not possible to determine system is investigated. CI candidacy based on other preoperative audiological The results show that it is possible to record tests. It has also been demonstrated that correct placement reproducible eABR measurements using PromBERA. The of the electrode tip on the round window (RW) niche, response was also confirmed with intraoperative eABR instead of the promontory, plays an important role on the measurements that were stimulated using the implanted CI efficacy of the electrical stimulation delivery [3]. electrode array. Similarities between the intraoperative In this study, we aim to investigate the feasibility of measurements and the preoperative recorded waveforms this measurement using the MED-EL clinical system, were observed. consisting of clinical software Maestro, MAX In summary, the integrity and excitability of the Programming Interface, Stimulator Box and the auditory nerve can be objectively measured using the transtympanic electrode. PromBERA in subjects where standard clinical testing procedures are unable to provide the information required. 2 Methods Keywords: promontory stimulation, electrical stimulation, electrical auditory brainstem response, trans- Eleven subjects underwent standard audiological tests for tympanic, cochlear implant, auditory nerve CI candidacy (Table 1), and the PromBERA test was performed on subjects where CI candidacy could not be determined. Under local anaesthesia, a transtympanic ______ rounded-bent tip electrode was placed temporarily on the * Corresponding author: Daniel Polterauer: Großhadern Clinic, RW niche and the surface ground electrodes were placed ENT: Cochlear Implant, Munich,Germany, e-mail: on the zygomatic bone and the angle of the mandible; [email protected] electrical impedance was checked and electrical Maike Neuling, Joachim Müller, John-Martin Hempel: Großhadern Clinic, ENT: Cochlear Implant, Munich,Germany stimulation was provided with the MED-EL Stimulator Giacomo Mandruzzato, Marek Polak: MED-EL, Research & Box and the MED-EL clinical Maestro v7.0 software. Development, Innsbruck, Austria Electrode placement was confirmed with Impedance Field Open Access. © 2018 Daniel Polterauer et al., published by De Gruyter. This work is licensed under the Creative Commons Attribution- NonCommercial-NoDerivatives 4.0 License. 564 — D. Polterauer et al.: PromBERA: A preoperative eABR: An update Telemetry (IFT) when the electrode impedance was lower S04 Left Craniocerebral injury 53 than 5 kΩ. S05 Left unknown 22 Biphasic alternating pulses with a phase duration S06 Right CSF leak 70 of 100 µs and a stimulation rate of 34 Hz were used. The S07 Right Acoustic neuroma 73 amplitude of the electrical pulses was increased with 100 S08 Left Unkown 60 cu/step until a response was detected. S09 Right NIHL 77 Electrical stimulation was provided by the CI S10 Left Unkown 22 electrode array for intra-operative measurements recorded S11 Left Trauma 42 immediately after insertion. Measurements were recorded from one apical, mid, and basal electrode. Biphasic alternating pulses with a phase duration of 40 µs with an increasing amplitude pattern were used until a response 3 Results was detected (Figure 1). Positive PromBERA results were confirmed in all subjects eABR measurements with presence of reproducible auditory responses after were electrical stimulation (Figure 2). The mean latency of the wave eV response was 4.23 ms (+/- 0.53 ms). Five subjects underwent CI implantation and intraoperative eABR measurements were recorded using the CI electrode array (Figure 3). Intraoperative eABR measurements across 4 subjects confirmed stimulation of the auditory nerve and auditory pathway. The mean latency of wave eIII was 1.94 ms (+/- 0.23 ms) and the mean latency of wave eV was 3.75 ms (+/- 0.24 ms). recorded Figure 1: Setup for PromBERA measurements with the MED- EL system. The Stimulator Box provides electrical pulses for PromBERA measurements (EP, evoked potential), whereas the electrical stimulation is provided by the implanted CI for intra-operative eABR measurements. using either the MEB9400 (Nihon Kohden) evoked potential device or the GSI Audera (Grason-Stadler) triggered using Maestro software and the MAX Programming Interface. Surface recording electrodes were applied to the contralateral mastoid (inverting), high forehead (non-inverting), and lower forehead (ground). The bandpass filter was set to 50-3000 Hz and the average number of sweeps were 1000 and 1500 for pre-/intra- Figure 2: PromBERA results elicited by trans-tympanic operative and post-operative eABR recordings, electrode placed on the RW niche for each subject. Red and respectively. blue marks indicate response peaks eIII and eV, respectively, while dashed marks indicate the troughs used for amplitude calculation. The subject number is indicated on the left axis Table 1: Subject demographics. and the vertical scale bar is depicted on the top. Subject Side Etiology Age at test S01 Left Sudden hearing loss (SHL) 40 S02 Right PHL 82 S03 Right SHL, Presbyacusis 78 D. Polterauer et al.: PromBERA: A preoperative eABR: An update — 565 Helsinki, and has been approved by the Ethic Commission of the faculty of Medicine, LMU Munich, Germany Project n. 412-13. References [1] Kuo, S. C. & Gibson, W. P. The role of the promontory stimulation test in cochlear implantation, Cochlear Implants Int, 2002, 3, 19-28. [2] Kileny, P. R. & Zwolan, T. A. Pre-perioperative, transtympanic electrically evoked auditory brainstem response in children, Int J Audiol, 2004, 43 Suppl 1, S16- 21. [3] Pau, H., Gibson, W. P., Sanli, H. Trans-tympanic electric auditory brainstem response (TT-EABR): the importance of the positioning of the stimulating electrode, Cochlear Implants Int, 2006, 7, 183 Figure 3: PromBERA (top) and intra-operative eABR (bottom) results measured for Subject 1. The electrical pulses were biphasic with alternating polarity at 300 cu /100 µs using a trans-tympanic electrode for the PromBERA and at 500 cu/40 µs with the CI electrode array for intra-operative eABR. Two PromBERA measurements are shown here, with red marks showing reproducible PromBERA measurements at 2.1 and 4.1 ms, which are confirmed with intra-operative eABR. The vertical scale bar is depicted on the right. 4 Conclusion These preliminary data show the validity of PromBERA. Intra-operative eABR results measured with the CI electrode array are similar to the results measured preoperatively with PromBERA. Finally, PromBERA with a MED-EL clinical system measurements are easy to record and can be used preoperatively to determine CI candidacy. Further data will be collected to compare intra-operative eABR with preoperative PromBERA in a wider group of subjects. Acknowledgements: The authors would like to thank Laura Kerr (MED-EL) for editing a version of this manuscript. Author Statement Research funding: The authors’ state that there was no funding involved. Conflict of interest: G. Mandruzzato and M. Polak are employed by MED-EL. Informed consent: Informed consent was obtained from all individuals included in this study. Ethics approval: The research related to human subjects complies with all relevant national regulations, institutional policies, and was performed in accordance with the Declaration of .
Details
-
File Typepdf
-
Upload Time-
-
Content LanguagesEnglish
-
Upload UserAnonymous/Not logged-in
-
File Pages3 Page
-
File Size-