Agilent 33500 Series 30 MHz Function / Arbitrary Waveform Generator User’s Guide Agilent Technologies This product utilizes Microsoft Windows Technology Licenses Notices CE. Agilent highly recommends that all Windows-based computers connected to The hardware and/or software © Agilent Technologies, Inc. 2010 Windows CE instruments utilize current described in this document are fur- No part of this manual may be repro- anti-virus software. For more information, nished under a license and may be used go to the product page at: duced in any form or by any means or copied only in accordance with the (including electronic storage and www.agilent.com/find/33521A terms of such license. retrieval or translation into a foreign www.agilent.com/find/33522A language) without prior agreement and Declaration of Conformity Restricted Rights Legend written consent from Agilent Technolo- gies, Inc. as governed by United States Declarations of Conformity for this If software is for use in the perfor- and international copyright laws. product and for other Agilent products mance of a U.S. Government prime may be downloaded from the Web. Go contract or subcontract, Software is Manual Part Number to http://regulations.corporate.agi- delivered and licensed as “Commercial lent.com and click on "Declarations of computer software” as defined in 33520-90001 Conformity." You can then search by DFAR 252.227-7014 (June 1995), or as product number to find the latest Decla- a “commercial item” as defined in FAR First Edition, June 2010 ration of Conformity. 2.101(a) or as “Restricted computer Second Edition, September 2010 software” as defined in FAR 52.227-19 Printed in Malaysia Warranty (June 1987) or any equivalent agency regulation or contract clause. Use, Agilent Technologies, Inc. The material contained in this duplication or disclosure of Software is 900 S. Taft Ave. document is provided “as is,” and subject to Agilent Technologies’ stan- Loveland, CO 80537 USA is subject to being changed, with- dard commercial license terms, and out notice, in future editions. Adobe, the Adobe Logo, Acrobat and non-DOD Departments and Agencies Further, to the maximum extent the Acrobat Logo are trademarks of of the U.S. Government will receive no permitted by applicable law, Agi- Adobe Systems Incorporated. greater than Restricted Rights as lent disclaims all warranties, defined in FAR 52.227-19(c)(1-2) Microsoft is either a registered trade- either express or implied, with (June 1987). U.S. Government users mark or a trademark of Microsoft Cor- regard to this manual and any will receive no greater than Limited poration in the United States and/or information contained herein, Rights as defined in FAR 52.227-14 other countries. including but not limited to the (June 1987) or DFAR 252.227-7015 implied warranties of merchant- Windows and MS Windows are U.S. (b)(2) (November 1995), as applicable ability and fitness for a particu- in any technical data. registered trademarks of Microsoft lar purpose. Agilent shall not be Corporation. liable for errors or for incidental Software Updates/Licenses or consequential damages in con- nection with the furnishing, use, Periodically, Agilent releases software or performance of this document updates to fix known defects and incorpo- or of any information contained rate product enhancements. To search for software updates and the latest documenta- herein. Should Agilent and the tion for your product, go to the product page user have a separate written at: agreement with warranty terms www.agilent.com/find/33521A covering the material in this doc- www.agilent.com/find/33522A ument that conflict with these A portion of the software in this product is terms, the warranty terms in the licensed under terms of the General Public separate agreement shall control. License Version 2 ("GPLv2"). The text of the license and source code can be found at: www.agilent.com/find/GPLV2 Safety Notices A CAUTION notice denotes a hazard. A WARNING notice denotes a haz- It calls attention to an operating proce- ard. It calls attention to an operating dure, practice, or the like that, if not procedure, practice, or the like that, correctly performed or adhered to, if not correctly performed or could result in damage to the product or adhered to, could result in personal loss of important data. Do not proceed injury or death. Do not proceed beyond a CAUTION notice until the beyond a WARNING notice until the indicated conditions are fully under- indicated conditions are fully under- stood and met. stood and met. Additional Safety Notices The following general safety precau- grounded power cable, with the ground In Case of Damage tions must be observed during all wire firmly connected to an electrical phases of operation of this instrument. ground (safety ground) at the power Instruments that appear damaged or Failure to comply with these precau- outlet. Any interruption of the protec- defective should be made inoperative tions or with specific warnings or tive (grounding) conductor or discon- and secured against unintended opera- instructions elsewhere in this manual nection of the protective earth terminal tion until they can be repaired by quali- violates safety standards of design, will cause a potential shock hazard that fied service personnel. manufacture, and intended use of the could result in personal injury. instrument. Agilent Technologies assumes no liability of the customer’s Do Not Operate in an failure to comply with the require- ments. Explosive Atmosphere Unless otherwise noted in the specifica- Do not operate the instrument in the tions, this instrument or system is General presence of flammable gases or fumes. intended for indoor use in an installa- Do not use this product in any manner tion category II, pollution degree 2 not specified by the manufacturer. The Do Not Remove the environment per IEC 61010-1 and 664 protective features of this product may Instrument Cover respectively. It is designed to operate at be impaired if it is used in a manner not a maximum relative humidity of 20% specified in the operation instructions. Only qualified, service-trained personal to 80% at 40 °C or less (non-condens- who are aware of the hazards involved ing). This instrument or system is should remove instrument covers. designed to operate at altitudes up to Before Applying Power Always disconnect the power cable and 2000 meters, and at temperatures Verify that all safety precautions are any external circuits before removing between 0 °C and 55 °C. taken. Make all connections to the unit the instrument cover. before applying power and select the appropriate power line voltage on the Do Not Modify the fuse module. Instrument Ground the Instrument Do not install substitute parts or per- form any unauthorized modification to This product is provided with protec- the product. Return the product to an tive earth terminals. To minimize shock Agilent Sales and Service Office for hazard, the instrument must be con- service and repair to ensure that safety nected to the ac power mains through a features are maintained. Technical Support Safety Symbols If you have questions about your Alternating current shipment, or if you need information about warranty, Frame or chassis service, or technical support, terminal contact Agilent Technologies: Standby supply. Unit is not In the United States: (800) 829- completely disconnected 4444 from AC mains when switch is off. In Europe: 31 20 547 2111 Caution, risk of electric shock In Japan: 0120-421-345 Or go to Caution, refer to accompanying documents www.agilent.com/find/assist for information on contacting Earth ground terminal Agilent in your country of specific location. You can also contact your Agilent Technologies The CE mark is a Representative. registered trademark of the European Community. The CSA mark is a registered trademark of the CSA-International. The C-tick mark is a registered trademark of the Spectrum Management Agency of Australia. This signifies compliance with the Australian EMC Framework regulations under the terms of the Radio Communications Act of 1992. Contains one or more of the 6 hazardous substances above the maximum concentration value (MCV), 40 Year EPUP. This text indicates that the instrument is an Industrial 1 S M 1 - A Scientific and Medical Group 1 Class A product (CISPER 11, Clause 4). This text indicates product compliance with the ICES/ Canadian Interference- NMB Causing Equipment -001 Standard (ICES-001). User’s Guide Publication Number 33520-90001 (order as 33520-90000 manual set) Edition 2, September 2010 Copyright © 2010 Agilent Technologies, Inc. Agilent 33500 Series 30 MHz Function / Arbitrary Waveform Generator Agilent 33500 Series at a Glance The Agilent Technologies 33500 Series is a 30 MHz synthesized waveform generator with built-in arbitrary waveform and pulse capabilities. Its combination of bench-top and system features makes this waveform generator a versatile solution for your testing requirements now and in the future. Convenient bench-top features • 16 standard waveforms • Built-in 16-bit 250 MSa/s arbitrary waveform capability • Precise pulse waveform capabilities with adjustable edge time • LCD display provides numeric and graphical views • Easy-to-use knob and numeric keypad • Instrument state storage with user-defined names • Portable, ruggedized case with non-skid feet Flexible system features • Downloadable 1M-point or optional 16M-point arbitrary waveform memories. For details, see: www.agilent.com/find/33521U www.agilent.com/find/33522U • Optional
Details
-
File Typepdf
-
Upload Time-
-
Content LanguagesEnglish
-
Upload UserAnonymous/Not logged-in
-
File Pages276 Page
-
File Size-