TOF-SIMS in Cosmochemistry Thomas Stephan ∗

TOF-SIMS in Cosmochemistry Thomas Stephan ∗

Planetary and Space Science 49 (2001) 859–906 www.elsevier.com/locate/planspasci TOF-SIMS in cosmochemistry Thomas Stephan ∗ Institut fur Planetologie=Interdisciplinary Center for Electron Microscopy and Microanalysis (ICEM), Westfalische Wilhelms-Universitat, Wilhelm-Klemm-Str. 10, 48149 Munster, Germany Received 21 June 2000; received in revised form 27 February 2001; accepted 27 February 2001 Abstract Time-of-.ight secondary ion mass spectrometry (TOF-SIMS) was introduced into cosmochemistry about a decade ago. Major advantages of TOF-SIMS compared to other ion microprobe techniques are (a) parallel detection of all secondary ions with one polarity in a single measurement—both polarities in subsequent analyses, (b) high lateral resolution, (c) su4cient mass resolution for separation of major mass interferences, and (d) little sample destruction. This combination makes TOF-SIMS highly suitable for the analysis especially of small samples, like interplanetary and presolar dust grains, as well as tiny inclusions within meteorites. Limitations of this technique are mainly referring to isotopic measurements and quantiÿcation. The possibility to measure molecular and atomic ion species simultaneously extends the applications of TOF-SIMS to the investigation of indigenous hydrocarbons in extraterrestrial material, which might have been essential for the formation of life. The present work gives an overview of TOF-SIMS in cosmochemistry, technical aspects as well as applications, principles of data evaluation and various results. c 2001 Elsevier Science Ltd. All rights reserved. Table of contents 1. Introduction...................................................................... 860 2. Principles of secondary ion mass spectrometry ..................................... 861 2.1. Generation of secondary ions ............................................... 861 2.2. Separation of secondary ions ............................................... 862 2.3. Quantiÿcation ............................................................. 862 2.4. Static and dynamic SIMS .................................................. 863 2.5. Charge compensation ...................................................... 863 2.6. Mass interferences ......................................................... 863 2.7. Mass resolution in time-of-.ight mass spectrometry .......................... 865 3. Time-of-ight secondary ion mass spectrometry ................................... 865 3.1. Secondary ion mass spectrometers .......................................... 865 3.2. Description of the TOF-SIMS instrument .................................... 866 3.3. TOF-SIMS mass spectra ................................................... 869 3.4. Quantiÿcation ............................................................. 870 3.5. Element analysis .......................................................... 872 3.6. SIMS sensitivities ......................................................... 876 3.7. Isotope analysis ........................................................... 877 3.8. Organic molecules ......................................................... 878 3.9. Data processing ........................................................... 878 ∗ Tel.: +49-251-8339050; fax: +49-251-8336301. E-mail address: [email protected] (T. Stephan). 0032-0633/01/$ - see front matter c 2001 Elsevier Science Ltd. All rights reserved. PII: S 0032-0633(01)00037-X 860 T. Stephan / Planetary and Space Science 49 (2001) 859–906 4. Meteorites ...................................................................... 879 4.1. Ca,Al-rich inclusions in carbonaceous chondrites ............................. 879 4.2. Organic molecules in Allan Hills 84001, Murchison, and Orgueil .............. 880 4.3. Further meteorite studies with TOF-SIMS ................................... 884 5. Interplanetary dust .............................................................. 885 5.1. Volatile elements .......................................................... 887 5.2. Mineral identiÿcation ...................................................... 887 5.3. The collector project ....................................................... 888 5.4. Particle impact residues from space probes .................................. 890 5.5. Further TOF-SIMS studies ................................................. 890 6. Presolar grains .................................................................. 891 6.1. Isotope measurements ..................................................... 891 6.2. Element mapping with TOF-SIMS .......................................... 892 7. TOF-SIMS in comparison ....................................................... 893 8. TOF-SIMS in space ............................................................. 893 9. Summary ....................................................................... 895 Acknowledgements ......................................................................895 Appendix ...............................................................................895 References ..............................................................................900 1. Introduction range from the analysis of rare earth elements in var- ious samples (e.g., Zinner and Crozaz, 1986; Bottazzi The analysis of micrometer-sized samples like, e.g., in- et al., 1994; Floss and JolliK, 1998; Fahey, 1998) to iso- terplanetary dust, presolar grains, and small inclusions in tope measurements (Zinner, 1989) in meteorites (e.g., meteorites has become more and more important in cosmo- McKeegan et al., 1998; Leshin et al., 1998; Chaussidon chemistry. Recent technical developments lead towards the et al., 1998; Eiler et al., 1998), interplanetary dust (e.g., ultimate analytical goal, the localization and identiÿcation of McKeegan et al., 1985; Zinner, 1991), presolar grains every single atom and its chemical bonding state in a sample. (e.g., Zinner et al., 1989; Zinner, 1991, 1998), and also The transmission electron microscope (TEM) with an ex- terrestrial (e.g., Froude et al., 1983; Chaussidon and Li- tremely high lateral resolution allows even seeing individual bourel, 1993; Didenko and Koval, 1994; Schuhmacher crystallographic layers. Therefore, this technique has been et al., 1994) and lunar (e.g., Compston et al., 1984) minerals. established widely into cosmochemistry (e.g., Tomeoka and Technical developments of conventional SIMS instruments Buseck, 1984, 1985, 1988; Bradley, 1994a). New develop- during the last years led to increased sensitivities at high ments in mass spectrometry like resonant ionization mass mass resolution and high spatial resolution. This culminated spectrometry (RIMS) enable to analyze the isotopic com- in the development of the Cameca IMS 1270, optimized position of an element that is present with just a few atoms for high mass resolution at high transmission (de Chambost (e.g., Hurst et al., 1979; Pellin et al., 1987; Ma et al., 1995; et al., 1992, 1997), and the Cameca Nanosims 50 with Nicolussi et al., 1996, 1998a). a lateral resolution of 50 nm (Hillion et al., 1994, 1997; Secondary ion mass spectrometry (SIMS) has also be- Stadermann et al., 1999a, b). come an increasingly important tool in geo- and cosmo- Finally, since the early 1990s, also time-of-.ight (TOF-) chemistry during the last two decades. After ÿrst develop- SIMS has been introduced to the analysis of extraterrestrial ments in the 1960s, a generation of instruments with high samples (Stephan et al., 1991; Radicati di Brozolo et al., mass resolutions like the Cameca IMS 3f and the SHRIMP 1991). (sensitive high mass resolution ion microprobe) allowed to Common to all diKerent SIMS techniques is that sec- introduce SIMS into this scientiÿc ÿeld mainly during the ondary ions are released from a sample surface by sputtering 1980s. Since then, this technique has been used for trace with a primary ion beam. In conventional ion microprobes, element analysis and isotope measurements in terrestrial as using mainly double-focusing magnetic mass spectro- well as extraterrestrial geological samples. The applications meters (DF-SIMS), diKerent secondary ions are usually T. Stephan / Planetary and Space Science 49 (2001) 859–906 861 measured sequentially during continuous sputtering. Since this process is destructive, the number of analyzed sec- ondary ion species is limited depending on the available amount of sample material or, because the analyzed ma- terial may change during sputtering, on the heterogeneity of the sample. In TOF-SIMS, the secondary ions are used more e4ciently. All secondary ion species with one po- larity, either positive or negative, are here detected quasi- simultaneously. Destruction of the sample is minimized by pulsing of the primary ion beam. The high transmission and in most cases su4cient mass resolution in combination with a high lateral resolution (∼0:2 m) makes TOF-SIMS highly suitable for the analysis of small samples. The aim of the present work is to summarize 10 years Fig. 1. The principle of secondary ion mass spectrometry: On the sample of analytical experience with TOF-SIMS in cosmochem- surface, an energy-rich primary ion beam generates secondary ions, which istry. After a more general introduction into the principles are separated and detected with a mass spectrometer. of secondary ion mass spectrometry, TOF-SIMS will be explained in detail with special emphasis on applications in cosmochemistry. The principles of TOF-SIMS data ac- quisition are illustrated as well as evaluation procedures

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    48 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us