Operating & Maintenance Operations Manual Manual Y-ViewTM Operator Interface Series IM 47K03A00-00E-A Yokogawa Corporation of America IM 47K03A00-00E-A 2 Dart road, Newnan, Georgia U.S.A. 30165 ©Copyright September 2012 Tel: 1-800-888-6400 Fax: 1-770-254-0928 1st Edition Record of Revisions Reference numbers are shown at the bottom left corner on the back cover of each manual. Printing Date Reference No. Revised Contents February, 2011 1058NE0 First edition Preface Congratulations on purchasing the drawing/editing software (Y-View Configurator) for the Y-View series. For a clearer understanding, the Y-View series Reference Manual focuses on the outline of each function and the way of using the drawing/editing software (Y-View Configurator) according to operating procedures. Notes: 1. The copyright of the software is possessed by Yokogawa Corporation of America. 2. Reproduction of the contents of the software and this manual, in whole or in part, without permission of Yokogawa Corporation of America, is prohibited. 3. The specifications of the software and the information in this manual are subject to change without prior notice. 4. If the specifications of the software do not correspond with the contents of this manual, the software specifications have priority. 5. No liability is assumed by Yokogawa Corporation of America, with respect to the influence brought by the result of using the software or this manual. 6. You may use this software on a single central processing unit. About Trademarks • Windows, Word and Excel are registered trademarks of Microsoft Corporation in the United States and other countries. • All other company names or product names are trademarks or registered trademarks of their respective holders. • Programmable logic controllers (PLCs) are products of their respective manufacturers. About Manuals This manual describes the structure, operating procedures and useful functions of the drawing software “Y-View Configurator” for the Y-View series. Following manuals are available for the Y-View series. Manual Name Contents Reference No. Y-View Series Reference The functions and instructions of the Y-View series are 1055NEx Manual explained. Y-View Series Macro An overview of macros as well as macro editor operations and 1056NEx Reference macro command descriptions are explained in detail. Y-View Series Introductory The basic operating procedure of Y-View Configurator is 1057NEx Manual explained in detail. Y-View Series Operation The information related to the operations of Y-View 1058NEx Manual (this manual) Configurator, such as software composition, editing procedure or limitations, is explained in detail. Y-View Series Reference: The additional functions of the Y-View series for the Y-View 1060NEx Additional Functions Configurator are explained. Y-View Series Hardware Notes on usage and hardware specifications for the Y-View 2016NEx Specifications series are explained. D057 Series Hardware Notes on usage and hardware specifications for the D057 2017NEx Specifications series are explained. D151 Hardware Notes on usage and hardware specifications for the D151 are 2018NEx Specifications described. Y-View Series Connection The connection and communication parameters for the Y-View 2201NEx Manual series and controllers are explained in detail. Y-View Series DLL An overview and contents of DLL files used for Ethernet 1059NEx Function Specifications (HKEtn20.DLL) and CF card (VCFAcs.DLL) are explained in detail. Y-View Series Models The following Y-View series models are available: Generic Name Series Model Y-View Series Classification D151-XGA Y-View Series D121-SVG Y-View Series D121-SVG Y-View Series D104-SVG Y-View Series D104-SVG Y-View Series D104-VGA Y-View Series D104-VGA Y-View Series D104-VGA Y-View Series D104-VGA Y-View Series D084-SVG Y-View Series D084-SVG Y-View Series D084-VGA Y-View Series Y-View Series Y-View series D084-VGA Y-View Series D057-TFT/ STN D057-TFT/ Y-View Series STN D057-MON D057-TFT/ STN D057-TFT/ Y-View Series STN D057-MON Please note that the Y-View series model names are used as listed above in the manuals. Y-View Series Functions The Y-View series is equipped with the following functions. Depending on the Y-View Series model, some functions may not be available. Please keep this limitation in mind. For more information, refer to the related chapter. Y-View Series Y-View Series Reference Manual Y-View Series Chapter Content D151- D121- D121- D104- D104- D057-T D057- XGA SVG SVG VGA VGA FT/STN TFT/S D104- D104- D084- D084- D057-T TN SVGD SVG VGA VGA FT/STN D057- 104-V D104- D057- TFT/S GA VGA MON TN D084- D084- D057- SVG SVG MON 2Overlap Superimpose Video overlap 3 Switch Coordinate output (for analog only) Transparency Multi-output Delay/Message box 4 Lamp Transparency 5 Data display 6 Message display Comment display 7 Entry mode Automatic writing when the entry target has been moved [Function: Cancel] switch [Function: Max./Min. Value Entry] switch Password: variable Digital switch (add/subtract switch) 8Graph Scale: variable 9 Trend graph XY parameters X scale 10 Sampling Acknowledge display function 11 Graphic 12 Time display/calendar 13 Recipe mode Y-View Series Reference Manual Y-View Series Chapter Content D151- D121- D121- D104- D104- D057-T D057- XGA SVG SVG VGA VGA FT/STN TFT/S D104- D104- D084- D084- D057-T TN SVGD SVG VGA VGA FT/STN D057- 104-V D104- D057- TFT/S GA VGA MON TN D084- D084- D057- SVG SVG MON 14 Multimedia Animation Video/RGB display JPEG display *1 *1 Sound replay function 15 Others Data block area Memory card mode CF card SRAM CREC Memo pad (for analog only) 16 Print Data sheet print Serial USB 17 Barcode One-dimensional Two-dimensional 18 CF card Built-in USB 2-drive connection 19 Ethernet function Screen data transfer PLC connection *2 *2 *2 E-mail Web server A1 Buffering area Store target: SRAM Store target: CF card A2 SRAM/clock setting A3 Display language Multi-language selection Displayed character selection Multi-language screen Windows fonts : Available : Optionally available : Not available *1 Not supported by D057-MON and D057-MON *2 Available only for UDP/IP. Functions Described in the Y-View Series Reference: Additional Functions Y-View Series Reference: Y-View Series Additional Functions Chapter Content D151- D121- D121- D104- D104- D057-T D057- XGA SVG SVG VGA VGA FT/STN TFT/S D104- D104- D084- D084- D057-T TN SVG SVG VGA VGA FT/STN D057- D104- D104- D057- TFT/S VGA VGA MON TN D084- D084- D057- SVG SVG MON 2 Switch Multi-function Continuous buzzer 3Word lamp 4 Data display with entry function Slider switch 5 Trend sampling graph show/hide function 6Alarm Parameter added Acknowledge 7 RGB display (touch switch emulation) 8 Scroll 9 Stroke fonts *1 *1 *1 *1 16-language selection 10 CF card Screen added Message storage Addition of titles to a sampling CSV file 11 Item display function 12 FTP server 13 E-mail certification Two Ethernet ports 14 Network camera *1 *1 *1*2 15 Remote desktop *1 *1 *1*2 (for analog only) 16 MES interface 17 Operation log/Log viewer 18 Security 19 Macro 20 Tag editing 21 Image file 3D part conversion Cross-reference 22 USB barcode reader USB keyboard USB mouse USB-FDD Y-View Series Reference: Y-View Series Additional Functions Chapter Content D151- D121- D121- D104- D104- D057-T D057- XGA SVG SVG VGA VGA FT/STN TFT/S D104- D104- D084- D084- D057-T TN SVG SVG VGA VGA FT/STN D057- D104- D104- D057- TFT/S VGA VGA MON TN D084- D084- D057- SVG SVG MON 23 Ladder transfer USB Ethernet : Available : Optionally available : Not available *1 The 128-color mode is not supported. *2 The D057-MON is not supported. Notes on Safe Usage of Y-View In this manual, you will find various notes categorized under the following levels with the signal words “DANGER,” and “CAUTION.” Indicates an imminently hazardous situation which, if not avoided, will result in death or DANGER serious injury. Indicates a potentially hazardous situation which, if not avoided, may result in minor or CAUTION moderate injury and could cause property damage. Note that there is a possibility that the item listed with CAUTION may have serious ramifications. DANGER Never use the input function of Y-View for operations that may threaten human life or damage the system, such as switches to be used in case of emergency. Please design the system so that it can cope with the malfunction of a touch switch. A malfunction of the touch switch will result in machine accident or damage. Turn off the power supply when you set up the unit, connect new cables, or perform maintenance or inspections. Failure to do so could cause electric shock or damage to the unit. Never touch any terminals while the power is on. Otherwise, electric shock may occur. You must put a cover on the terminals on the unit when you turn the power on and operate the unit. Without the terminal cover in place, electric shock may occur. The liquid crystal in the LCD panel is a hazardous substance. If the LCD panel is damaged, do not ingest the leaked liquid crystal. If the liquid crystal spills on skin or clothing, use soap and wash off thoroughly. For Y-View using a lithium battery, never disassemble, recharge, deform by pressure, short-circuit, reverse the polarity (+/) of the battery, or dispose of the battery in fire. Failure to follow these conditions will lead to explosion or fire. For Y-View using a lithium battery, never use a battery that is deformed, leaks, or shows any other signs of abnormality.
Details
-
File Typepdf
-
Upload Time-
-
Content LanguagesEnglish
-
Upload UserAnonymous/Not logged-in
-
File Pages611 Page
-
File Size-