FIRE SAFETY SYSTEMS S. NO NAME & ADDRESS SUGGESTIONS REMARKS PROVIDED IN THIS BUILDING 1. Number of fire extinguishers provided has to be increased as per IS 2190. REPCO BANK First Aid Fire extinguisher in 7 no’s 2. Down Comer system should be provided. Non Compliance 1. No. 55, 4th Main Road, Adyar, provided. 3. Over head water tank capacity should be increased to of Fire Safety Chennai – 20 5000 liters. Norms. 4. Obstruction in the side setback area should be cleared. 1. Fire extinguishers have to be provided as per IS 2190. Door No. 43, Rajalakhsmi st 2. Hose Reel System should be provided. Non Compliance Palace, Gandhi Nagar, 1 2. NIL 3. Down Comer System should be provided. of Fire Safety Main Road, Adyar, 4. Over head water tank capacity should be increased to Norms. Chennai - 20 5000 liters. 1. Hose Reel System should be provided. 2. Down Comer System should be provided. Ashok Kumar Guleeha Non Compliance First Aid Fire Extinguisher – 3. Over head water tank capacity should be increased to 3. No. 102, L.B. Road, of Fire Safety ABC – 4kg in four no’s provided. 5000 liters. Adyar, Chennai – 20 Norms. 4. Obstruction in the side setback area should be cleared. 1. Hose Reel System installed in all 1. Hospital Emergency Rescue Team should be formed. the floors. 2. Obstruction in the side setback area should be Santhosh Hospital 2. Automatic Smoke Detection cleared. Non Compliance 4. No. 1, 7th Avenue, system provided. 3. One Ramp should be provided. of Fire Safety Besant Nagar, Chennai – 90 3. Automatic Sprinkler system insta- 4. Exit Signage’s should be provided. Norms. lled. 5. Suitable Fire Extinguisher’s has to be provided at 4. Fire Extinguisher provided. suitable area. 1. Fire extinguisher should be provided as per IS 2190. Janaki Apartment 2. Hose Reel system should be provided at all floors. Non Compliance Plot no. 74, D.No. 204, Sardar 5. NIL 3. Fire alarm system should be provided. of Fire Safety Patel Road, Adyar, 4. Obstruction in the side setback area should be Norms. Chennai – 20 cleared. 1. Wet Riser System provided. 2. Down Comer System provided 3. Manual Call Point provided 4. Automatic Smoke Detection System provided. 5. Automatic Sprinkler System provided. Ramco Systems 6. First Aid Fire Extinguisher’s 1. Necessary 7 meters side setback area should be Non Compliance 6. D.No. 64, Sardar Patel Road, provided. provided. of Fire Safety Adyar, Chennai – 20 7. Public Addressed system Norms. provided. 8. Pumps provided: i. Electrical Pump – 100 HP ii. Diesel Pump – 90 HP iii. Jockey Pump – 20 HP iv. 1. Fire extinguishers have to be provided as per IS. Suruthi Apartments 2. Down Comer System should be provided. Non Compliance D.No. 21, Plot No. 135, 3. Hose Reel System should be provided. 7. nd NIL Of Fire Safety 2 Main Road, Gandhi Nagar, 4. Side setback obstructions should be removed. Norms. Adyar, Chennai – 20 5. Over head water tank capacity should be increased to 5000 liters. 1. Down comer system should be provided. 2. Hose Reel system should be provided. 3. Terrace tank capacity of 5000 liters should be Keerthi Vasan Non Compliance First Aid Fire Extinguisher 4 no’s provided. 8. No. 78, Sardar Patel Road, of Fire Safety provided. 4. Fire Alarm system should be provided. Adyar, Chennai – 20 Norms. 5. Side setback obstructions should be removed. 6. Fire Pump Capacity of 900 LPM should be provided at terrace level. 1. Number of fire extinguishers provided has to be increased as per IS 2190. Dev Apartments st 2. Hose Reel system should be provided. Non Compliance No. 5, Kasthuri Bhai Nagar, 1 First Aid Fire Extinguishers 17 no’s 9. 3. Down Comer system should be provided. of Fire Safety Main Road Adyar, provided. 4. Over head water tank capacity should be increased to Norms. Chennai – 20 5000 liters. 5. Side setback obstructions should be removed. 1. Fire extinguishers have to be provided as per IS 2. Hose Reel system should be provided. st 3. Down Comer should be provided. D.No. 6, 1 main road, First Aid Fire Extinguishers Non Compliance 4. Over head water tank capacity should be increased to 10. Kasthuri Bhai Nagar, ABC 4kg type– 7 no’s, Co2 – 4.5kg Of Fire Safety 5000 liters. Adyar, Chennai – 20 type – 4 no’s provided. Norms. 5. Fire Pump Capacity of 900 LPM should be provided at terrace level. 6. Side setback obstructions should be removed. 1. Number of fire extinguishers provided has to be Ceebross Arcade increased as per IS 2190. Non Compliance No. 1, IIIrd Cross street, First Aid Fire Extinguishers 5 no’s 2. Hose Reel system should be provided 11. of Fire Safety Kasthuri Bhai Nagar, provided. 3. Down Comer System should be provided Norms. Adayar, Chennai – 20 4. Over head water tank capacity should be increased to 5000 liters. 1. Number of fire extinguishers provided has to be increased as per IS 2190. No. 34/36, First Aid Fire Extinguishers Non Compliance th 2. Hose Reel system should be provided. 12. 7 Avenue, Besant Nagar, installed at commercial area Of Fire Safety 3. Down Comer System should be provided. Chennai – 90 - 3 no’s (ABC type 4kg) Norms. 4. Fire Pump Capacity of 900 LPM should be provided at terrace level. 1. Fire extinguishers have to be provided as per IS 2. Hose Reel system should be provided. 3. Over head water tank capacity should be increased to Non Compliance No. 32/34 Coastal Road, 13. NIL 5000 liters. of Fire Safety Besant Nagar, Chennai – 90. 4. Side setback obstructions should be removed. Norms. 1. Fire extinguishers have to be provided as per IS Sea Port Apartments 2. Hose Reel system should be provided. Non Compliance No. 41/70, Beach Road, 3. Over head water tank capacity should be increased to 14. NIL Of Fire Safety Kalakshetra Colony, 5000 liters. Norms. Besant Nagar, Chennai – 90 4. Side setback area obstructions should be removed. 5. Alternative staircase should be provided. 1. Fire Extinguisher should be installed as per IS 2190. 2. Wet riser system should be provided. 3. Hose Reel system should be provided. 4. Fire alarm system should be provided. Gokul Arcade 5. Side setback area at northern side and southern side Non Compliance First Aid Fire Extinguisher provided 15. No. 2, Sardar Patel Road, setback area violation should be cleared. Of Fire Safety in few quantities. Adyar, Chennai – 20 6. Manual Call Points system should be provided. Norms. 7. Over head water tank capacity should be increased to 5000 liters. 8. Pumps: Electrical – 2280 lpm, Diesel – 2280 lpm, Jockey – 180 lpm st 1. Down Comer system should be provided. No. 37/87, 1 Main Road, Non Compliance First Aid Fire Extinguishers 12 no’s 2. Hose Reel system should be provided. 16. Gandhi Nagar, Adyar, of Fire Safety provided. 3. Obstruction in the side setback area should be Chennai – 600 020. Norms. cleared. Hotel Shreelekha Regency Pvt ltd Fire Extinguishers – Co2 – 10 no’s 17. No. 564, Anna Salai, DCP 4.5kg – 2 no’s provided. All Fire Fighting systems are available. Teynampet, Chennai – 18 18. G.R. Ganesh 1. Down Comer system with Hose Reel assembly should Non Compliance No. 23, Padmanathan Road be installed. of Fire Safety and Lioyds Road, 2. Fire Extinguishers have to be provided as per IS 2190. Norms. Gopalapuram, Chennai – 86 19. Mr. K. Ramaniyam & Others 1. Down Comer system with Hose Reel assembly should Non Compliance No. 16, Centoph Road, 1st be installed. of Fire Safety Street, Chennai – 18 2. Fire Extinguishers have to be provided as per IS 2190. Norms. 20. The Sarala Chorida & others 1. Manual Call Points provided. 1. Wet riser system with hose reel assembly should be Non Compliance No. 171, Avvai Shanmugam 2. Smoke Detection system provided. of Fire Safety Salai, Gopalapuram, provided. 2. One electrical and Diesel Pump capacity of 2280 LPM Norms. Chennai – 86 3. Fire extinguishers ABC –type 6kg and a jockey pump with capacity of 180 LPM should - 6 no’s, Co2 type – 2kg – 6 no’s be provided. provided. 1. Wet riser system with hose reel assembly should be provided. 2. One electrical and Diesel Pump capacity of 2280 lpm and a jockey pump with capacity of 180 lpm should be provided. M.A. Jacob Non Compliance 3. Sprinkler system should be installed. 21. No. 11, Damodran Street, of Fire Safety NIL 4. Smoke Detector with MCP should be installed. Gopalapuram, Chennai – 86 Norms. 1. Wet riser system with hose reel assembly should be Ashok Kumar Goel 1. Hose Reel system with Hydrant provided. Geetha Bhavan Trust, Non Compliance provided. 2. One electrical and Diesel Pump capacity of 2280 lpm 22. No. 334, Avvai Shanmugam of Fire Safety 2. Fire extinguishers ABC type – and a jockey pump with capacity of 180 lpm should be Salai, Gopalapuram, Norms. 4kg – 13 no’s provided. provided. Chennai - 86 3. Smoke Detector with MCP should be installed. Ram Chand 1. Down Comer system with Hose Reel assembly should Non Compliance 23. No. 7, Kasturi Rangan Road, NIL be provided. of Fire Safety Gopalapuram, Chennai – 86 2. MCP should be provided. Norms. 1. Wet riser system with hose reel assembly should be provided. Meridian Appearels Ltd 2. One electrical and Diesel Pump capacity of 2280 lpm Non Compliance No. 121/3, Manickam Avenue, Fire extinguishers DCP type – 2kg – and a jockey pump with capacity of 180 lpm should be 24. of Fire Safety T.T.K. Road, Alwarpet, in 10 no’s provided. provided. Norms. Chennai – 18 3. Sprinkler system should be installed.
Details
-
File Typepdf
-
Upload Time-
-
Content LanguagesEnglish
-
Upload UserAnonymous/Not logged-in
-
File Pages13 Page
-
File Size-