Sample Preparation for Scanning Electron Microscopy (SEM)

Sample Preparation for Scanning Electron Microscopy (SEM)

Sample preparation for Scanning electron microscopy (SEM) SEM is primarily useful for giving a three‐dimensional image of the surface of the specimen and is for viewing large objects. As with TEM, specimens are imaged with a beam of electrons, but instead of the electrons being transmitted through the specimen, the beam is "scanned" across, creating an image of the surface of the sample, with exceptional depth of field. This image is achieved via the detection of "secondary" electrons that are released from the specimen as a result of it being scanned by very high energy "primary" electrons (ie. those emitted from the electron "gun" in the SEM). As most biological specimens are made up of non‐dense material the amount of secondary electrons produced is too low to be of much use in creating an image and therefore they are usually coated with a very fine layer of a metal which readily produces secondary electrons. The large depth of field achievable can produce an image of great visual depth with a three‐dimensional appearance. The operating environment of a standard scanning electron microscope dictates that specialist preparation techniques are used. Typically, a biological specimen is chemically fixed, dehydrated through an acetone or ethanol series and then dried at the critical point ‐ a method used to minimize specimen distortion due to drying tensions. For dry samples, this process is not necessary. SEM can also be used to investigate smooth surfaces of industrial samples. The samples are mounted on a stub of metal with adhesive, coated with 40 ‐ 60 nm of metal such as Gold/Palladium and then observed in the microscope. Every sample is different. Please consult with the EM Staff before starting a project. Epidermoid carcinoma cells. Epidermoid carcinoma Staphylococcus Aureus. Bar: 2 µm cells. Bar: 2 µm Bar: 2 µm Side 1 Small intestine, villi. Small intestine, microvilli Plastinated glomerulus from Bar: 200 µm. on the surface of a villus. rat. Tissue is removed. Bar: 50 µm. Fly Spider Hair – on the surface. Bar: 200µm. Bar: 300µm. Bar: 10µm. SEM services include: Fixation and dehydration Critical point drying Drying with hexamethyldisilazane (HMDS) and t‐Butanol Coating with Gold/Palladium using Sputter coater Image processing (software Scandium) Side 2 .

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    2 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us