EXECUTIVE SUMMARY OF DRAFT EIA REPORT ENVIRONMENTAL IMPACT ASSESSMENT FOR CONSTRUCTION OF ADDITIONAL MS STORAGE TANK AT SURYAPET TERMINAL OF HPCL, IMAMPET VILLAGE, NALGONDA, TELANGANA. PREPARED BY: H INDUSTAN PETROLEUM CORPORATION LIMITED SGS India Private Limited 226 Udyog Vihar Phase I Gurgaon – 122 016, Haryana, India PROJECT REFERENCE NUMBER : Tel: +91 124 6776300 IN/ES-EIA/2015-178 Fax: +91 124 6776403/04 (V ERSION 1.0) http://www.sgsgroup.in/ WHEN YOU NEED TO BE SURE Executive Summary of Draft EIA Report for Construction of Additional MS Storage Tanks of 5000 Kl at Suryapet Terminal of HPCL, Imampet Village, Nalgonda District (Telangana) 1. Background Hindustan Petroleum Corporation Limited (HPCL) is a Government of India Enterprise with a Navaratna Status, and a Forbes 2000 and Global Fortune 500 company, refining and marketing Public Sector Undertaking (PSU). HPCL owns & operates 2 major refineries producing a wide variety of petroleum fuels & specialities, one in Mumbai (West Coast) of 6.5 Million Metric Tonnes Per Annum (MMTPA) capacity and the other in Visakhapatnam, (East Coast) with a capacity of 8.3 MMTPA. HPCL also owns and operates the largest Lube Refinery in the country producing Lube Base Oils of international standards, with a capacity of 428 TMT. HPCL has a vast supply and distribution infrastructure comprising depots, terminals, pipeline networks, aviation service stations, LPG bottling plants, inland relay depots and retail outlets, lube and LPG distributorships. Hindustan Petroleum Corporation Limited (HPCL) has an existing installation at Suryapet in Nalgonda district of Telangana State for the purpose of receipt, storage and dispatch of petroleum products (POL) such as motor spirit (MS), high speed diesel (HSD) and superior kerosene (SKO). The terminal is receiving the petroleum products through VVSPL from HPCL Refinery, Visakhapatnam. Petroleum products are stored in various above ground and underground storage tanks and are distributed to various customers by loading the tank trucks. Suryapet terminal is an intermediate stock point for feeding HPCL’s retail outlets (RO) in the Suryapet surrounding areas to ensure that there is no disruption in the feed from the terminals to the retail outlets. The existing Suryapet terminal consists of six above ground and five underground tanks. HPCL obtained environmental clearance vide letter No. J-11011/76/99-IA.II dated 11.04.2000 from Ministry of Environment, Forest & Climate Change (MOEF&CC) for petroleum pipeline project from Vijayawada to Secunderabad. Presently, HPCL’s Suryapet Terminal is having 6 floating roof tanks for storage of MS (2x3780 kl), HSD (2x18150 kl), SKO (2x1500 kl). The terminal mainly has facilities for receipt of petroleum products through pipelines, storage & handling of different petroleum products. In order to meet market demands, HPCL has proposed to install additional tank of 5000 Kl capacity for storage of Motor Sprit (Petrol) to meet the requirement of retail outlets. SGS India Pvt. Ltd. ii Executive Summary of Draft EIA Report for Construction of Additional MS Storage Tanks of 5000 Kl at Suryapet Terminal of HPCL, Imampet Village, Nalgonda District (Telangana) The construction of additional storage tank of 5000 kl capacity at Suryapet Terminal of HPCL will improve supply position of the petroleum products which is vital for economic growth as well as improving the quality of life. The improved petroleum products supply will have strong logistical support for delivering the products to customers without interruption. The project will also provide indirect employment to unskilled, semiskilled and skilled categories. 4.1 Purpose of the Report As per EIA Notification S.O. No 1533 issued on 14th September, 2006 and its subsequent amendments the proposed project is falling under Schedule 6(b) – Isolated storage & handling of hazardous chemicals and ‘Category B’. Hence, this project requires Environmental Clearance from State Environmental Impact Assessment Authority (SEIAA). Accordingly, the EIA Report has been prepared based on the Standard Terms of Reference issued for “Isolated Storage & Handling of Hazardous Chemicals” (as per threshold planning quantity indicated in Column 3 of Schedule 2 & 3 of MSIHC Rules 1989 amended 2000). The application for EC (Form-1) along with a copy of compliance report dt. 27.07.2015 was submitted to SEIAA, Telengana on 20.06.2015 and the same was reviewed by the Expert Committee held on 30.07.2015. TOR has been issued by SEIAA vide letter No. SEIAA/TS/NLG-15/2015 dated 29.03.2016. This EIA report is prepared in line with TOR conditions recommended by SEIAA committee. HPCL appointed SGS India Pvt. Ltd., Gurgaon (NABET Accredited EIA Consultant) as EIA Consultant for preparation of Environment Impact Assessment (EIA) and Environment Management Plan (EMP) for providing technical support for obtaining environment clearance as per EIA Notification. SGS India Pvt. Ltd. iii Executive Summary of Draft EIA Report for Construction of Additional MS Storage Tanks of 5000 Kl at Suryapet Terminal of HPCL, Imampet Village, Nalgonda District (Telangana) 2. Project Description The proposed project is construction of additional MS storage tank of 5000 KL . After construction of additional storage tank the supply position of the petroleum product will improve. As per the EIA Notification The details of existing as well as proposed storage tanks capacity of the Suryapet Terminal are furnished below: 3.1 Land Requirement Suryapet Terminal of HPCL is located on the 28.02164 Acres area land. The total land (including the land required for proposed MS tank) is under possession of HPCL. Total Area of Terminal : 113400 sqm (28.02164 Acres) Tank Truck Parking Area : 46000 sqm (11.3668 Acres) Green Belt Area : 59400 sqm (14.678 Acres), 52.4 % SGS India Pvt. Ltd. iv Executive Summary of Draft EIA Report for Construction of Additional MS Storage Tanks of 5000 Kl at Suryapet Terminal of HPCL, Imampet Village, Nalgonda District (Telangana) Existing as well as Proposed Storage Capacity at Suryapet Terminal Sn. Tanks Type of Tank Petroleum Capacity Dimension Mode of Safety Measures Provided Nos Product (Kl) (Diameter x transportation/ Stored height) Pipeline Diameter I. Existing 1A Above MS 3780 20.5 x 13.0 Pipeline Inlet : 10” Rim Seal Fire Protection, Ground Outlet : 20” Fixed Foam System, Floating Sprinkler System, MEFG, Roof Tank HVLR, Foam Monitors 1B Above MS 3780 20.5 x 13.0 Inlet : 10” Rim Seal Fire Protection, Ground Outlet : 20 “ Fixed Foam System, Floating Sprinkler System, MEFG, Roof Tank HVLR, Foam Monitors 2A Above SKO 1500 15.5 x 9.5 Pipeline Inlet : 10” Foam Monitors, Foam Ground Outlet : 12” Trolley Floating Roof Tank 2B Above SKO 1500 15.5 x 9.5 Pipeline Inlet : 10” Foam Monitors, Foam Ground Outlet : 12” Trolley Floating Roof Tank 3A Above HSD 18150 37.5 x 18 Pipeline Inlet : 10” Fixed Foam System , Ground Outlet : 16” Sprinkler System , MEFG, Floating HVLR, Foam Monitors Roof Tank 3B Above HSD 18150 37.5 x 18 Pipeline Inlet : 10” Fixed Foam System , Ground Outlet : 16” Sprinkler System , MEFG, Floating HVLR, Foam Monitors Roof Tank 003 U/G TANK Ethanol 70 2.7 x 11.7 Pipeline Inlet : 4 “ Mobile Foam Trolley, Foam Outlet : 4 “ Monitors SGS India Pvt. Ltd. v Executive Summary of Draft EIA Report for Construction of Additional MS Storage Tanks of 5000 Kl at Suryapet Terminal of HPCL, Imampet Village, Nalgonda District (Telangana) Sn. Tanks Type of Tank Petroleum Capacity Dimension Mode of Safety Measures Provided Nos Product (Kl) (Diameter x transportation/ Stored height) Pipeline Diameter 005 U/G Tank Ethanol 45 3.0 x 6.6 Pipeline Inlet : 4 “ Mobile Foam Trolley, Foam Outlet : 4 “ Monitors 001 U/G Tank MS 50 2.5 X 9.7 Pipeline Inlet : 3” Mobile Foam Trolley, Foam outlet : 3” Monitors 002 U/G Tank SKO 50 2.5 x 9.7 Pipeline Inlet : 3” Mobile Foam Trolley, Foam outlet : 3” Monitors 004 U/G Tank SLOP 22 2.0 x 6.5 Pipeline Inlet : 3” Mobile Foam Trolley, Foam outlet : 3” Monitors 101 U/G Tank MS/SKO/ 18.8 2.0 x 6.0 Pipeline Inlet : 10” & Foam Monitors HSD 4” Outlet : 3 “ 102 U/G Tank MS/SKO/ 70 3.0 x 11.0 Pipeline Inlet : 10” & Foam Monitors HSD 4” Outlet : 3 “ II. Proposed 1 C Above MS 5000 23.0 x 13.0 Not yet finalized Rimseal Fire Protection Ground System, Fixed Foam Floating Roof System, Sprinklers, HVLR, Tank Foam Monitors SGS India Pvt. Ltd. vi Executive Summary of Draft EIA Report for Construction of Additional MS Storage Tanks of 5000 Kl at Suryapet Terminal of HPCL, Imampet Village, Nalgonda District (Telangana) 3.2 Power Requirement The average power consumption per month is approximately 52000 units at Suryapet Terminal. Three DG Sets with capacity of 800 kVA, 200 kVA and 180 kVA are available to meet the power requirements during grid power failure. Normally, these sets are operated 10 minutes per day for testing purpose. Occasionally, these are operated maximum of four hours in the event of grid power failure. Height and diameter of the stack a attached with DG sets 800 kVA DG Set : Height : 12 m from Ground : Diameter : 8 Inch (0.2 m) 200 kVA DG Set : Height : 12 m from Ground : Diameter : 6 Inch (0.15 m) 180 kVA DG Set : Height : 12 m from Ground : Diameter : 4 Inch (0.1 m) All three DG sets are provided with acoustic enclosures. 3.3 Water Requirement The maximum water requirement during operation phase of the Suryapet Terminal is as given below: Sl. No. Particulars Max. Quantity 1 Domestic Use 4 kld 2 Greenery / landscape Development 10 kld 3 Topping of Fire Water Tanks 15 kld Total 29 kld The water requirement is met through 3 bore wells at existing Suryapet Terminal. 3.4 Fire Fighting Facility at Suryapet Terminal Suryapet Terminal layout and firefighting system design as per OISD STD 117 and being upgraded to OISD STD 244.
Details
-
File Typepdf
-
Upload Time-
-
Content LanguagesEnglish
-
Upload UserAnonymous/Not logged-in
-
File Pages18 Page
-
File Size-