14 Spectroscopy 21(7) July 2006 www.spectroscopyonline.com Mass Spectrometry Forum Electron Ionization Sources: The Basics The ion source is the heart of the mass spectrometer. In the ion source, ions are created from gas-phase neutral sample molecules, or preformed ions are extracted from solu- tions, and then sent into the mass analyzer of the instrument. The electron ionization (EI) source was the first source widely used for organic mass spectrometry (MS), and design, development, and optimization of this source are all the result of the work of many of the early pioneers of MS. Kenneth L. Busch he sensitivity of a mass spectrometer (the source and optimization are overlooked in the fact that the EI combined with the remainder of the instrument, but source is so common. Lack of current research literature on Tsometimes also the source itself) is defined strictly in the design of the EI source reflects the long history of suc- units of C/␮g, where C represents the charge in coulombs cessful development of this source for organic analysis, the carried by ions that can be created from 1 ␮g of sample in- tendency for design studies to be completed now in con- troduced to the source. The sensitivity of any MS measure- junction with instrument manufacture (and therefore to be ment is predicated first upon instrument sensitivity (includ- proprietary), and the attention given to new ionization ing factors such as source performance, mass analyzer methods. However, more specialized applications of the EI transmission, and ion detection efficiency), but also ex- source often require revisiting these fundamental design pa- pands to include sample preparation, signal-to-noise dis- rameters; examples of these applications include portable crimination, and matrix effects in real samples. The central instruments and instruments for analysis in extreme envi- position of source performance in this scheme should be ronments. Importantly, an appreciation of the factors con- clear. For EI sources, source design and operational details sidered in the design of the EI source, the balances reached directly affect source performance. It is useful then to in accord with the transfer of sample molecules into the broadly consider the 50-year history of the EI source in source, and the transfer of ions out of it informs our de- terms of sensitivity, and its optimization, but also to include signs and evaluations of other ionization sources. In this all the other factors that go into the design and construction column, we begin a brief overview of some of these factors of an ion source. and balances; then in the next column, we revisit some of We begin with the essential elements of the EI source. Es- the “older” scientific literature and hopefully enlighten the sential components of an EI source assembled into the basic understanding of source design for mass spectrometers. layout can be found in schematics in introductory texts or The basic function of an EI source is to create ions from manufacturer’s literature on the web. Often it seems that neutral gas-phase sample molecules M, according to the short shrift is given to the EI source, and details of design equation: www.spectroscopyonline.com July 2006 21(7) Spectroscopy 15 2 (ϪW/kT) the minimum amount of energy re- js = A T e o ϩ Ϫ → ϩ. Ϫ M e filament M + e mol- quired to remove an electron from the ϩ Ϫ ecule e filament surface of a metal. The relationship where jS is the current density of the between work function and tempera- emission (mA/mm2), A is Richardson’s where the electrons causing molec- ture is described in “older” research constant (approximately 1202 ular ionization are emitted usually literature (3,4) and is summarized in mA/mm2 K2), T is temperature (K), W from a heated metal filament. In most the Richardson–Dushman equation is the work function of the cathode EI sources, the filament is made of (5,6), which relates the emitted cur- material (J), and k is the Boltzmann tungsten or rhenium, fabricated as a rent density to the work function (W) constant (1.38066 ϫ 10Ϫ23 J/K). wire, a coil, or sometimes a ribbon. and temperature (T) of the emitting The filament operates in a vacuum Figure 1 is a photograph of such a fila- material: such that the heated metal does not ment, and the coiled structure can be immediately oxidize, become brittle, clearly seen. The coil (or multiple rib- bons) provides a greater surface area from which thermionic emission of electrons can occur. Specialized mate- rials that have been used, often in the higher operating pressures of residual gas analyzers, include thoriated irid- ium (thoria coated onto a supporting iridium wire) and yttriated iridium. Other specialized applications demand other filament materials; these are compiled in Manura’s authoritative texts on the subject (1,2). Tungsten is cheapest, but it produces carbon diox- ide by reactions of hydrocarbons at the heated metal surface. This is not usually an issue in organic MS, which usually does not scan to that low of a mass or attach high interpretive value to the ion at m/z 44, but the interfer- ence is something to be aware of in other applications. Rhenium filaments produce carbon dioxide to a lesser ex- tent due to the lower work function of rhenium and the resultant lower oper- ating temperature. However, rhenium filaments emit stable rhenium oxide negative ions that can be a potential mass interference in some analyses. The filament is heated by a robust power supply that passes current suffi- cient to heat the filament to its operat- ing temperature. Because the power supply provides 3–4 amperes at 70 V relative to ground (more on that later), great care must be taken to avoid personal contact with the out- put. The current passage raises the temperature of the filament to a point at which the work function of the heated metal is exceeded, and elec- trons are then released from the sur- face of the metal in a process of thermionic emission. Remember that the work function is defined simply as Circle 15 16 Spectroscopy 21(7) July 2006 www.spectroscopyonline.com stant. This period is reached when a balance is achieved between heat gen- eration due to the passage of the fila- ment current and loss of heat to the source block. The current passed through the filament heats not only the wire itself, but through radiation and some convection, it also heats sur- rounding metal. The source block is the metal “container” into which gas- phase sample molecules and electrons are introduced and contained, and from which ions are extracted into the mass analyzer. The internal volume of a typical EI source block is on the order of 1 mL; for miniaturized in- struments it can be less. It is instruc- tive to calculate the mean free path of an ideal gas at the pressure and tem- perature at which the EI source oper- ates and compare that value with the dimensions of the source block itself. The source block is heated by radiative emission from the filament and by dedicated source heaters as well to minimize the time required to reach an equilibrium operating temperature and to maintain source cleanliness. The normal operating temperature is 180–220 °C, depending on what sorts of samples are being brought into the source. Why is the source block heated? Re- call that hot metal often catalyzes or- ganic sample decomposition, so it Figure 1: Photograph of a coiled filament used in an electron ionization source. Look closely to seems that this would be a bad idea see the ion burn behind the filament. Cropped from an original photograph taken by Frederick from the start. In this case, however, Strobel, Manager of the Mass Spectrometry Facility at Emory University, and used with the source is heated to prevent con- permission. densation of gas-phase sample mole- cules onto the “cold” metal walls, lead- ing to source contamination through and fracture, much as an incandescent columns, the pressure of the reagent sample cross talk, as well as a generally lightbulb filament will burn out in a gas in the source is about 1 torr. Resul- “dirty source” through condensation few seconds if the surrounding glass tant changes in basic design and oper- of the background organic vapors al- envelope that maintains the inert at- ation of the source, including the fila- ways present in the instrument. Sam- mosphere is breached. The equation ment, to accommodate this higher ple cross talk occurs when the sample that describes thermionic emission as- operating pressure are discussed in an molecules adsorb on the surface, re- sumes emission into a vacuum, and so upcoming parallel series of columns main there for some time that be- the fit of theoretical equation to ex- on the design and operation of the comes similar to the time between the perimental results is good (subject to CI source. introduction of the subsequent sam- corrections such as the Schottky ef- Stable electron emission from a ple, and then desorb from the surface. fect). Remember that the pressure of metal filament (as clear from the The ideal situation is that neutral gas- sample molecules in the EI source will equation above) requires a few min- phase sample molecules are intro- be about 10Ϫ6 torr, or about the same utes of operation to reach a thermal duced into the source and are as the base pressure of the instrument “equilibrium,”or more accurately, a promptly ionized or pumped away out itself. In a chemical ionization (CI) constant temperature at which the flux of the source, with no residue.

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    5 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us