CWP 100, Model H/S Operator’S Guide Important User Information Copyright © 2012 by Mar Cor Purification, Inc

CWP 100, Model H/S Operator’S Guide Important User Information Copyright © 2012 by Mar Cor Purification, Inc

Mar Cor Purification CWP 100, Model H/S Operator’s Guide Important User Information Copyright © 2012 by Mar Cor Purification, Inc. All rights reserved. No part of the contents of this manual may be reproduced, copied, or transmitted in any form or by any means including graphic, electronic, or mechanical methods or photocopying, recording, or information storage and retrieval systems without the written permission of the publisher, unless it is for the purchaser's personal use. The information in this manual is subject to change without notice and does not represent a commitment on the part of Mar Cor Purification (MCP). MCP does not assume any responsibil- ity for any errors that may appear in this manual. In no event will MCP be liable for technical or editorial omissions made herein, nor for direct, indirect, special, incidental, or conse- quential damages resulting from the use or defect of this man- ual. The information in this document is not intended to cover all possible conditions and situations that might occur. The end user must exercise caution and common sense when install- ing, using, or maintaining MCP products. If any questions or problems arise, call MCP Technical Services at 1-800-633- 3080. Intended Use MCP products are intended to be installed and used as described in this manual and other related MCP literature. CWP 100, Model WRO H/S Table of Contents Table of Contents Important User Information . 2 Intended Use. 2 Table of Contents. 3 Preface . 7 Safety Messages . 7 Safety Considerations. 7 List of Symbols . 9 Certification Marks . 10 IPR — Intellectual Property Rights . 10 Trademarks . 10 Copyright . 10 Manufacturer . 10 Introduction . 11 Intended use . 11 General Function . 11 Pretreatment . 11 Distribution Loop . 11 Hot Water Circulation . 12 Chemical Disinfection . 12 Water quality. 12 Microbiology . 12 Chemical Quality . 12 Operation . 15 Operator Panel . 15 Operator Panel Description . 16 Button Descriptions . 17 Operating Instructions. 19 Operating Modes. 19 Lamp Indication Unit (option). 20 Operating in Local-Manual Mode . 21 Manual Operation Start . 21 Manual Hot Water Circulation . 22 Operating in Local-Autostart Mode . 23 Starting in Autostart. 23 Autostop . 23 Hot Water Circulation . 24 Autostop Hot Water Circulation . 24 Chemical Disinfection . 25 Local . 25 Pause Chemical Disinfection. 25 Start After Chemical Disinfection. 26 P/N 3027367 Rev. C 3 Table of Contents CWP 100, Model WRO H/S Post Run . 27 Post Run with Stop . 27 Post Run with Hot Water Circulation . 27 Local Mode . 27 Regular Maintenance . 29 Water Sample . 29 Collecting a Water Sample . 29 Chemical Disinfection . 29 Frequency . 29 Changing Solution Containers . 30 To Change Container . 30 Disinfectant Amount . 30 Required Disinfectant Amount. 31 Stopping Chemical Disinfection. 31 Technical Data . 33 Performance and Specifications . 33 Product Water . 33 Water Supply. 33 Drain Requirements. 34 Service Connections . 34 Membranes . 34 Power Supply . 35 Measurement Ranges . 35 Logging Interface. 35 Physical Data . 36 Dimensions . 36 Heating Tank . 36 Weight . 36 Environmental Data . 36 Ambient Temperature . 36 Safety . 37 Troubleshooting. 39 Alarm Information . 39 Power Failure . 39 Water Supply Interruption . 39 Flow Alarms. 40 Restoring Alarms . 40 To Reset an Alarm. 40 Alarm List . 41 Appendix. 45 Appendix 1 — Operating Instructions . 45 Local Auto with Autostop. 46 Local Auto with Manual Stop. 47 Local Post Run . 48 4 P/N 3027367 Rev. C CWP 100, Model WRO H/S Table of Contents Appendix 2 — Advanced Handling . 49 Main Menu. 49 Disengage Water Saving. 51 Appendix 3 — Log List (Daily Check) . 52 Index . 53 P/N 3027367 Rev. C 5 Table of Contents CWP 100, Model WRO H/S This is a blank page. 6 P/N 3027367 Rev. C CWP 100, Model WRO H/S Preface Preface This manual provides information needed to operate the water purifica- tion unit, CWP 100, model WRO H/S. Publication nunber 3027367 Title Operator´s Guide PLC program version RU0901Vx Panel program version RU0901Vx CAUTION! At delivery, the CWP unit is filled with a preservation and anti- freeze solution containing less than 1 percent formaldehyde and 10 percent glycerine. This solution must be thoroughly rinsed from the unit before the CWP unit is put into operation. Make sure that no residual formaldehyde can be detected before connecting patients. Safety Messages WARNING! Is used to alert the user not to take a certain action which, if done, can create a potential hazard and result in a serious adverse reaction, injury or death. A warning may also be used to alert the user to take a certain action to avoid the potential hazard. CAUTION! Is used to alert the user to take a certain action to protect against a potential hazard which, if ignored, can create an adverse effect on the patient or the device. A caution may also be used to alert the user not to take a certain action to avoid the potential hazard. NOTE It is a reminder to the user during normal operation for what is a suit- able action in a situation. Safety Considerations WARNING! Unauthorized modifications, alterations or repair of the CWP water purification unit may result in malfunctioning or have other serious consequences for the safe operation of the equipment. P/N 3027367 Rev. C 7 Preface CWP 100, Model WRO H/S WARNING! Dialysis machines that are to be connected to the distribution loop supplied with water from a MCP CWP water purification unit must comply with IEC 60601-2-16. CAUTION! • The CWP water purification unit may only be operated by per- sons trained in this equipment and who have read and under- stand this Operator’s Manual. If the CWP water purification unit does not perform as described in the Operator’s Manual, it should not be used until the condition is rectified. • When unpacking, check the equipment for any signs of dam- age. If the equipment is in any way damaged, proper opera- tion can not be assured. • The installation and start up of CWP water purification unit must be made by authorized personnel. • The use of mobile telephones or communication equipment in the vicinity of the CWP water purification unit could adversely influence the performance of the machine. • The CWP water purification unit will perform as designed only if it is used and maintained in accordance with MCP instruc- tions. Any warranties made by MCP with respect to the CWP water purification unit are void if the equipment is not used in accordance with the instructions provided. MCP will not accept responsibility for any damage or injury resulting from improper use or maintenance or unauthorized repair. • The user must verify the quality of the protective earth ground in the installation. • When used as a medical device, U.S. Federal law restricts this device for sale only by the order of a physician. 8 P/N 3027367 Rev. C CWP 100, Model WRO H/S Preface List of Symbols NOTE All symbols in this list may not be represented on this product. Alternating current Protective earth (ground) Warning, consult accompanying documents Off (power, disconnection from the mains) On (power, connection to the mains) Type B, applied part Handle with care This way up Keep dry Separate collection for electrical and electronic equipment Input /Output Year of manufacturing ME equipment and ME systems that include RF transmitters or that intentionally apply RF electro- magnetic energy for diagnosis or treatment shall be labeled with this symbol. P/N 3027367 Rev. C 9 Preface CWP 100, Model WRO H/S Certification Marks The ETL mark indicates that the water purification unit, CWP 100, Model WRO H and CWP.

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    56 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us