Mass Spectrometry (MS)

Mass Spectrometry (MS)

Mass Spectrometry (MS) • Technique for studying the masses of atoms or molecules or fragments of molecules • Provides information about … o Elemental composition o Molecular structure o Composition of complex mixtures o Structure & composition of solid surfaces o Isotopic ratios of atoms • Discriminate between 79Br & 81Br Mass Spectrometry Applications Skoog, Table 20-5 Mass Spectrometry Beginnings • Aston (Cambridge) o 1919 – Discovered two isotopes of neon (20Ne & 22Ne) • 1922 – Nobel Prize in Chemistry Francis William Aston o “for his discovery, by means of his mass spectrograph, of isotopes, in a large number of non-radioactive elements, and for his enunciation of the whole-number rule" • Discovered 212 of 281 naturally occurring isotopes www.nobel.se Obtaining a Mass Spectrum • Gaseous molecules desorbed from condensed phases are ionized • Ions are accelerated by an electric field • Ion separation by mass-to-charge ratio (m/z) ethyl benzene Skoog, Fig. 20-1 The Instrument • Sample ionization o Gas-phase o Desorption • Mass analyzer ~ monochromator o Quadrupole (Q) o Time-of-flight (TOF) o Double-focusing (B, E) o Ion trap • Ion transducer o Electron multiplier o Faraday cup Skoog, Fig. 11-1 Ion Transducers • Electron multiplier o Analogous to a photomultiplier tube (PMT) o Rugged & reliable o Current gain ~ 107 • Faraday cup o Inexpensive o Simple mechanically & electrically o Less sensitive than electron multiplier Skoog, Fig. 11-2(b), 11-3 Ion Sources Basic Type Name and Acronym Ionizing Agent Gas phase Electron impact (EI) Energetic electrons Chemical ionization (CI) Reagent gaseous ions Field ionization (FI) High-potential electrode Desorption Field desorption (FD) High-potential electrode Electrospray ionization (ESI) High electrical field Matrix-assisted desorption/ionization (MALDI) Laser beam Plasma desorption (PD) Fission fragments from 252Cf Fast atom bombardment (FAB) Energetic atomic beam Secondary ion mass spectrometry (SIMS) Energetic beam of ions Thermospray ionization (TS) High temperature Skoog, Table 20-1 Electron Ionization (EI) • Electrons accelerated through potential of 70 V and interact with incoming molecules M + e– → M+• + e– + e– 70 eV Molecular ~55 eV 0.1 eV ion • Interaction with 70-eV Formaldehyde electron will likely remove electron with lowest ionization energy o n < < Harris, 6th ed., Fig. 22-3 Electron Ionization (EI) • Path of electrons & molecules are at right angles o Collide to produce mostly singly-charged positive ions • Inefficient process Skoog, Fig. 20-3 Chemical Ionization (CI) • Ionization source is filled with a reagent gas o CH4,C4H10, NH3,H2, CH3OH, NO • Energetic electrons (100 – 200 eV) convert CH4 to a variety of reactive products: CH 4 e CH 4 2 e CH 4 CH 4 CH 5 CH 3 CH 4 CH 3 H CH 3 CH 4 C 2 H 5 H 2 CH 5 M CH 4 MH C2H 5 M C2H 4 MH EI vs. CI Mass Spectra BASE PEAK • Hard source • Soft source o More fragmentation o Less fragmentation • Structural information • Molecular weight o Functional groups information Harris, Fig. 21-14 EI vs. CI Mass Spectra • 1-Decanol mass spectra • Hard source o More fragments o Structural info • Soft source o Less fragments o MW info Skoog, Fig. 20-2 Electrospray Ionization (ESI) • Sample typically in form of solution (organic or aqueous) • Excess solvent must be removed before entering MS o Large increase in pressure from solvent vaporization • Differential solvent removal o Solution passed through stainless steel capillary tube o Apply high electric potential (3 – 5 kV) o Solvent evaporates rapidly from droplet surface and droplets get smaller and smaller o Solvent molecules diffuse away Electrospray Ionization (ESI) Harris, 6th ed., Fig. 22-16 (b); (Skoog, Fig. 20-8) Laser Desorption Ionization (LDI) • Molecular system exposed to laser beam has its internal energy greatly increased o Melting o Vaporization o Ionization o Decomposition • Process of beaming laser light onto small area of sample specimen to desorb ions Herbert, C. G.; Johnstone, R. A. W.; Mass Spectrometry Basics; 2003, p. 8 Matrix-Assisted Laser Desorption Ionization (MALDI) • Aqueous/alcohol solution of sample is mixed with radiation-absorbing matrix to TOF-MS material o Matrices (Skoog, Table 20-4) • Solution evaporated on metallic probe surface • Solid mixture is exposed to pulsed laser beam o Analyte is sublimed as ions • Useful for obtaining accurate molecular weights of biopolymers Source: http://www.srsmaldi.com ESI & LDI Pioneers • Fenn (Virginia Commonwealth) & Tanaka (Shimadzu) • 2002 – Nobel Prize in Chemistry o "for the development of methods for John B. Fenn identification and structure analyses of biological macromolecules" o "for their development of soft desorption ionization methods for mass spectrometric analyses of Koichi Tanaka biological macromolecules" Source: http://www.nobel.se Fast Atom Bombardment (FAB) • Focus a high primary current beam of neutral atoms or molecules on sample • Sample dissolved in non-volatile liquid matrix • Inert gas atoms are ionized to give positive ions • As ions collide with other inert gas atoms (He, Ar, Xe), charge exchange occurs o Fast-moving ions become fast- moving atoms Source: http://www-methods.ch.cam.ac.uk/meth/ms/theory/fab.gif Secondary Ion Mass Spectrometry (SIMS) • Focus a high primary current beam of ions on sample • Sample dissolved in non- volatile liquid matrix • Dynamic SIMS o Current beam high enough to damage surface o Elemental and isotopic information obtained • Static SIMS o Dedicated to analysis of top monolayer of surface o Fresh layer of new ions continuously brought to surface Source: http://www.chemistry.wustl.edu/~walker/sims_exp.gif; http://www.ulb.ac.be/sciences/cpmct/images/logosims.gif Magnetic Sector (B) • Ions deflected according to their mass • Spectrum obtained by changing the field strength m B2r 2 z 2V m/z = mass-to-charge ratio B = magnetic field strength r = radii of curvature (trajectory) V = accelerating voltage Harris, 6th ed., Fig. 22-2; (Skoog, Fig. 20-12) Electrostatic Sector (E) • Ions deflected according to their kinetic energy o KE = ½mv2 Harris, 6th ed., Fig. 22-12 Double-Focusing • Combination of magnetic & electrostatic sectors o Improved resolving power • Resolution of 105 o Compatible with chromatographic columns o Compact • Configurations o Mattauch-Herzog • Skoog, Fig. 11-9 o Nier-Johnson • Skoog, Fig. 20-13 Mattauch-Herzog Source: http://www.oup.com/images/booksites/higson/higson_fig9.8.jpg Double-Focusing Ion Optics Forward Geometry EB Configuration (Nier-Johnson) Reverse Geometry BE Configuration Herbert, C. G.; Johnstone, R. A. W.; Mass Spectrometry Basics; 2003, p. 178-179 Time-of-Flight (TOF) Harris, 6th ed., Fig. 22-14; (Skoog, Fig. 11-8) Quadrupole (Q) Harris, Fig. 21-13; (Skoog, Fig. 11-4) Ion-Trap Harris, 6th ed., Fig. 22-15; (Skoog, Fig. 20-15) Hyphenated MS Methods • Mass spectrometer = detector for other analytical techniques o Mass spectra collected as compounds exit • Chromatography/MS o Gas Chromatography/MS (GC-MS) o Liquid Chromatography/MS (LC-MS) • Capillary Electrophoresis/MS (CE-MS) Chromatography/Mass Spectrometry • MS requires high vacuum o Avoid molecular collisions during ion separation • Chromatography is high-pressure technique o Must remove huge excess matter between the chromatograph and the spectrometer • For GC, narrow capillary column connected directly to inlet of the mass spectrometer • For LC, liquid from column creates huge volume of gas when vaporized o Pneumatically assisted electrospray o Atmospheric pressure chemical ionization (APCI) APCI • Uses heat and coaxial flow of N2 to convert eluate into a fine aerosol mist • Creates new ions from gas-phase reactions between ions & molecules • High voltage is applied to metal needle in the path of the aerosol Harris, 6th ed., Fig. 22-18 Liquid Chromatography/MS (LC-MS) Harris, 6th ed., Fig. 22-16 (a) Gas Chromatography/MS (GC-MS) • Must remove most of the carrier gas from the analyte • Quadrupole or ion trap mass analyzers used Skoog, Fig. 27-13, 27-14 Capillary Electrophoresis/MS (CE-MS) • Capillary effluent is passed into an electrospray ionization device • Products enter quadrupole mass analyzer • Detection limits: tens of femtomoles (10–14 M) Skoog, Fig. 30-7 Chromatography/MS Spectra GC CE Herbert, C. G.; Johnstone, R. A. W.; Mass Spectrometry Basics; 2003, p. 264 Tandem Mass Spectrometry (MS/MS) First MS Second MS • Isolates molecular ions • Fragments ions • Soft ionization source o Collisions between ions & He atoms cause o Molecular ions or protonated molecular ions further fragmentation • “Daughter” ions • “Parent” ions • Analogous to • Provides series of mass chromatographic column spectra for each molecular ion produced o Provides pure ionic species for second spectrometer QQQ Tandem Instrument • Q1 &Q3 are regular quadrupole filters • Q2 is a collision focusing chamber o Helium pumped into chamber & collides with parent ions o Operates in rf-mode only • Focuses scattered ions but does not act as a mass filter Skoog, Fig. 20-24 The Mass Spectrum • Molecular ion (M+•) = unknown molecular mass • M+• breaks apart efficiently with EI o Fragments provides clues about structure • CI mass spectrum has strong MH+ peak o Molecular mass information • Nitrogen Rule o Odd nominal mass for M+• • Odd # N atoms o Even nominal mass for M+• • Even # N atoms Harris, Fig. 21-14 Molecular Ion & Isotope Patterns • M+●peak is base peak for aromatic compounds o EI spectra • Next higher mass peak provides elemental composition info o M + 1 peak • Carbon Intensity of M + 1 relative to M+●for C H : o 98.92 % 12C n m Intensity = n × 1.08 % + m × 0.012 % o 1.08 % 13C • Hydrogen 13C 2H o 0.012 % 2H Benzene: Intensity = 6 × 1.08 % + 6 × 0.012 % = 6.55 % Biphenyl: Intensity = 12 × 1.08 % + 10 × 0.012 % = 13.1 % Harris, Fig. 21-18 Molecular Ion & Isotope Patterns Harris, Table 21-1 Rings and Double Bonds • Rings + double bonds (R + DB) formula o Used if composition of a molecular ion is known h n R DB c 1 2 2 c = # of Group 14 atoms (e.g., C, Si) [make 4 bonds] h = # of (H + halogen) atoms [make 1 bond] n = # of Group 15 atoms (e.g., N, P) [make 3 bonds] 22 11 11 R DB 14 1 15 rings & double bonds 2 2 Harris, 6th ed., p.

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    44 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us