Client: Jakir Ali G e o f f B y : r e y n g G a i MIBC. MBEng, MIAS. r f a w i t 43 Cresswell Road Darnall Sheffield. S9. 4JN. D r Corporate Building Engineer t 51 Sevenairs Road. 'Brookmere Park' Beighton. Sheffield. S20. 1NY. 0 or 0114-248-3623 E-mail 439000m 439100m c These Drawings Are The Copyright Of Geoffrey Garfitt No Part Of These Drawings Are To Be Copied Or Reproduced Without The Written Consent Of The Designer. All Drawings and Specification have been Prepared, for the purposes of obtaining Town and Country Planning Permission and Building Regulation Approvals ONLY. The passing of the plans operates as an approval only for the purposes of the requirements of the Building Regulations 2010 and those sections of the Building Act 1984, Clean Air Act 1956, which expressly require or P O authorise the Council in certain cases to reject plans. O LE R O A d If under Section 32 of the Building Act 1984, this work is not commenced D a o within three years of the deposit of the notice or plans, they will be R Posts l considered as null and void, and for this work to be undertaken, a fresh l 30 e notice and deposit of plans will be required. 84 w 73.0m s s In accordance with Regulation 15 you are required to notify this Council of certain stages e r of building work associated with your application. C Nursing Home Not all the inspections listed from 1 to 10 below may be applicable to your application. 387600m 43 387600m The minimum time period for notifying the Council is referred to in brackets. Requests for inspections should be made no later than 16:00 hours on the day prior to you 13 El requiring your inspection. Requests received after 16:00 hours cannot be guaranteed. Sub Sta 80 16 78 1. Commencement of works (not less than 48 hours prior to commencement). 49 2. Excavations prior to concrete (not less than 24 hours prior to concreting). 3. Foundation concrete (not less than 24 hours prior to backfilling). 28 71.3m 4. Oversite prior to concrete (not less than 24 hours prior to concrete). 1 45 4 5. Damp proof course (not less than 24 hours prior to backfilling). 70 6. Drainage prior to backfilling (not less than 24 hours prior to backfilling). 74 7. Drainage after backfilling (not more than 7 days after backfilling). 71.0m 8. First fix for all electrics and upper floor joists prior to covering up (not less than 24 hours). P 87 oo 9. Occupation, or part thereof (not less than 5 days before occupation). le R oad 10. Completion of building works (note more than 5 days after completion of works). 63 81 37 77 75 The Party Wall Act 1996 C 71 Anyone proposing to carry out work of the kinds detailed below oli must give adjoining owner notice of their intentions: ste 67 r D riv PH Work directly on an existing party wall or structure e 14 New buildings at or astride the boundary wall between properties 17 15 11 Excavation near a neighbouring building or structure depending upon the depth of excavation. 7 1 The Party Wall Act 1996: Explanatory Booklet can be obtained free 27 21 of charge from ODPM FREE LITERATURE, PO Box 236, WEST YORKSHIRE, 5 2 LS23 7NB. TELEPHONE 0870-122-6236, TEXTPHONE 0870-120-7405 387500m 25 23 1 387500m The Construction (Design and Management) Regulations 2015 These do generally apply to smaller projects and work by a 30 9 householder on their own property. Further guidance is available from 1 4 the Health and Safety Executive who may be contacted 01142 912 300 42 or 0870 1545500. See attached notes. 24 s n 11 e d r a 15 G Mr. Jakir Ali r Client: e t s i l 47 14 12 o 19 C 11 54 43 Cresswell Road 15 These Drawings Are The Copyright Of Geoffrey Garfitt No - Part Of These Drawings Are To Be Copied Or Reproduced Without - The Written Consent Of The Designer. DARNALL Location: 1 3 SHEFFIELD. S9. 4JN. South Yorkshire Proposed Detached Garage with Storage Project: over to a Private Dwelling. 439000m 439100m Scale: A3 1:1250 Crown Copyright. All rights reserved. Licence no. 100041040 Title: Property as Existing Date: MARCH 2021 Drawing Number 2021-01 Ref: ALI Client: Jakir Ali G e o f f B y : r e y n g G a i MIBC. MBEng, MIAS. r f a w i t D r Corporate Building Engineer t 51 Sevenairs Road. 'Brookmere Park' Beighton. c These Drawings Are The Copyright Of Geoffrey Garfitt No Part Of These Drawings Are To Be Copied Or Reproduced Without The Written Consent Of The Designer. All Drawings and Specification have been Prepared, for the purposes of obtaining Town and Country Planning Permission and Building Regulation Approvals ONLY. The passing of the plans operates as an approval only for the purposes of the requirements of the Building Regulations 2010 and those sections d of the Building Act 1984, Clean Air Act 1956, which expressly require or authorise the Council in certain cases to reject plans. a If under Section 32 of the Building Act 1984, this work is not commenced within three years of the deposit of the notice or plans, they will be considered as null and void, and for this work to be undertaken, a fresh o notice and deposit of plans will be required. In accordance with Regulation 15 you are required to notify this Council of certain stages of building work associated with your application. Not all the inspections listed from 1 to 10 below may be applicable to your application. Existing Log Cabin R The minimum time period for notifying the Council is referred to in brackets. Requests for inspections should be made no later than 16:00 hours on the day prior to you requiring your inspection. Requests received after 16:00 hours cannot be guaranteed. l 1. Commencement of works (not less than 48 hours prior to commencement). l 2. Excavations prior to concrete (not less than 24 hours prior to concreting). 3. Foundation concrete (not less than 24 hours prior to backfilling). 30 4. Oversite prior to concrete (not less than 24 hours prior to concrete). e 5. Damp proof course (not less than 24 hours prior to backfilling). 6. Drainage prior to backfilling (not less than 24 hours prior to backfilling). k r 7. Drainage after backfilling (not more than 7 days after backfilling). o y r w a 8. First fix for all electrics and upper floor joists prior to covering up (not less than 24 hours). k d c i n 9. Occupation, or part thereof (not less than 5 days before occupation). r u b o w 10. Completion of building works (note more than 5 days after completion of works). d b i l l o a s g The Party Wall Act 1996 e l Raised Patio m / l Anyone proposing to carry out work of the kinds detailed below l m s a 5 must give adjoining owner notice of their intentions: w 2 Conservatory 2 y Work directly on an existing party wall or structure r g a n i d New buildings at or astride the boundary wall between properties t n s s i u Excavation near a neighbouring building or structure depending x o b E upon the depth of excavation. The Party Wall Act 1996: Explanatory Booklet can be obtained free e of charge from ODPM FREE LITERATURE, PO Box 236, WEST YORKSHIRE, r LS23 7NB. TELEPHONE 0870-122-6236, TEXTPHONE 0870-120-7405 The Construction (Design and Management) Regulations 2015 These do generally apply to smaller projects and work by a householder on their own property. Further guidance is available from the Health and Safety Executive who may be contacted 01142 912 300 C or 0870 1545500. See attached notes. Ex istin Mr. Jakir Ali g 22 Client: bou 5mm ndar sol y w id br all/le ickw gal ork boun 43 Cresswell Road dary 43 These Drawings Are The Copyright Of Geoffrey Garfitt No - Part Of These Drawings Are To Be Copied Or Reproduced Without - The Written Consent Of The Designer. DARNALL Location: 13 SHEFFIELD. S9. 4JN. South Yorkshire Proposed Detached Garage with Storage Project: over to a Private Dwelling. Scale: A3 1:200 Title: Property Block Plan as Existing Date: MARCH 2021 Drawing Number 2021-02 Ref: ALI Client: Jakir Ali G e o f f B y : r e y n g G a i MIBC. MBEng, MIAS. r f a w i t D r Corporate Building Engineer t 51 Sevenairs Road. 'Brookmere Park' Beighton. Sheffield. S20. 1NY. or 0114-248-3623 c These Drawings Are The Copyright Of Geoffrey Garfitt No Part Of These Drawings Are To Be Copied Or Reproduced Without The Written Consent Of The Designer. All Drawings and Specification have been Prepared, for the purposes of obtaining Town and Country Planning Permission and Building Regulation Approvals ONLY. The passing of the plans operates as an approval only for the purposes of the requirements of the Building Regulations 2010 and those sections d of the Building Act 1984, Clean Air Act 1956, which expressly require or authorise the Council in certain cases to reject plans. a If under Section 32 of the Building Act 1984, this work is not commenced within three years of the deposit of the notice or plans, they will be considered as null and void, and for this work to be undertaken, a fresh o notice and deposit of plans will be required.
Details
-
File Typepdf
-
Upload Time-
-
Content LanguagesEnglish
-
Upload UserAnonymous/Not logged-in
-
File Pages6 Page
-
File Size-