
An in-process instrument for the measurement of nano- particle size distribution and electrophoretic mobility Jason CW Corbett, Fraser McNeil-Watson & David McKnight 1 Malvern Instruments Ltd, Grovewood Road, Enigma Business Park, Malvern, Worcestershire, UK, WR14 1XZ , [email protected] ABSTRACT: Real-time monitoring of physical parameters is a key requirement of process systems in particle manufacturing for either industrial or academic applications. We present an in- process, high pressure (10 bar) flow cell instrument for the combined measurement of particle-size distribution, electrophoretic mobility & conductivity at nano-scales. The measurement performance is characterised in flow and at high concentration in both forward and backscatter. Keywords Electrophoretic mobility, high concentration. 1. INTRODUCTION Real-time and on-line monitoring of physical parameters, such as particle size and electrophoretic mobility, is of primary interest in automated and semi-automated processes such as wet milling, chemical reactors and colloidal and protein manufacturing systems in general. These systems often combine high flow throughput and high concentrations, especially in colloidal applications, making measurements based on light scattering challenging. However, with the ability of dynamic light scattering (DLS) to measure particle size distributions (PSD) repeatably and reproducibly at the physical scales associated with nano-particle manufacture, there is renewed interest in applying it to flowing and/or concentrated systems. This includes interest in both calibrated measurements based, perhaps, on the real-time monitoring of some aspect of a highly concentrated manufacturing process and then associating this measured value with an off-line diluted measurement of the primary PSD or electrophoretic mobility and on partially diluted, direct, measurements. We present a dynamic light scattering instrument fitted with a flow cell, capable of operating at up to 10 bar, for applications requiring live monitoring of particle size, electrophoretic mobility and conductivity in the size range 0.6nm to 6 µm. The instrument itself is described in detail in section 2. Characterisation of the size performance in flow over various size bands is investigated in section 3 and electrophoretic mobility in section 4. 2. THE INSTRUMENT 2.1 OPTICS AND MEASUREMENT PRINCIPLES The instrument is based on the Malvern Zetasizer Nano ZS platform. Utilising an avalanche photodiode detector, the default optics are configured to provide a back-scattered size measurement using the non-invasive backscatter (NIBS)[1] technology with a forward scattered measurement of the electrophoretic mobility using the phase analysis light scattering technique (PALS) [2] . With reference to figure 1(a), the size is measured using photon correlation spectroscopy (PCS) with an onboard correlator. The size is measured in the self beating, homodyne configuration. The time correlated signal is then reduced using a regularised non-negative least squares (NNLS) fitting of multiple exponentials yielding the particle size distribution. PCS is capable of detecting the difference between a fully monomeric and monomeric + higher order oligomer sample at the sub 10nm scale. Further, DLS is capable of detecting each individual oligomer if connected to a size exclusion chromatography system. The NIBS system uses a translation stage to place the back-scattered, detected volume inside the flow cell over a continuous range. Highly dilute samples are measured in the cell centre so that heterodyning from light scattered from the cell wall is not detected. Concentrated samples are measured nearer to the cell wall where any component of the total detected light scattered from stationary surfaces, such as the cell wall, is a tiny proportion of the light scattered from the concentrated sample. However the much reduced path length of both the incident laser into the cell and the detected path back out of the cell are shortened. This significantly reduces the susceptibility of the measurement to multiple scattering and allows the precise and accurate measurement of far higher concentrations. (a) (b) Figure 1 – (a) The size optical geometry (electrodes not shown), (b) the electrophoretic mobility geometry (reference path + modulator not shown) The electrophoretic mobility is measured in a heterodyne configuration using a Mach-Zender interferometer and the phase analysis light scattering PALS [] technique – In this work we collect and compare data in both forward (17 degrees in air) (figure 1(b)) or in back scatter (173 degrees in air) – using the size detection direction in panel (a). Note that the reference path with optical light modulator are not shown for brevity – See reference [2] for more details. The electrodes form part of the side walls of the flow cell as shown. A fibre interferometer was used in the back-scattered mobility measurement, which proved to be as stable as its fixed optical counterpart with the added convenience of tight packing of the fibre within the instrument. With the incident laser and detected beam direction in the scattering plane (horizontal in figure 1), the q vector is given by, q = 2knsin (θ ) (1) 2 Where, θ is the detection angle, with respect to the incident laser beam, n the refractive index of the medium in which the angle is measured and the wavelength of the incident light λ = 2π /k. At 633 nm , the wavelength used in the system described above, |qback | ≈ 8.817 |qforward | . * PALS samples the (pseudo-stationary) phase, ϕI, of the light scattered from the fringes by the charged particles under motion due to the electric field E in the detection volume. Each sample of ϕ consists of a small time resolved measurement of the intensity at the detector I(t) th of duration δt. The i sample, Ii(t) obeys, ∝ + ∈[ + δ ] I i (t) sin( φi ωt) t,t t (2) where ω is the modulator angular frequency. Many such consecutive samples of ϕi yield a phase change per unit time, φ = ϕ( t), to which an electrophoretic mobility, µ (µmcm/Vs) in a known field E ( V/cm), can be assigned via φ = q µE (3) By inspection of equation (2), in order for phase demodulation to work efficiently the phase value ϕi must be assumed to be pseudo-stationary on the sample, δt. Since the detected phase change per unit time is dependent on | q| then the sampling must also increase in the back-scattered regime to compensate – i.e. the interval δt must decrease to maintain the pseudo-stationarity of ϕi on the interval. Again for demodulation to work, the modulated phase component, ωt, must also be at least Nyquist sampled and the modulator frequency must then be increased in backscatter to be adequately sampled within δt. The sampling was optimised separately for the forward and back scattered cases. However, the response of the sample to the applied electric field is not dependent on the detection angle so the field reversal settings (required to stop bulk charge migration and subsequent field cancellation between the electrodes) are identical for both cases. 2.2 FLOW CELL The same cell, shown in figure 2 prior to mounting in the unit, is used for size, mobility and conductivity measurements and is arranged so that the flow is orthogonal to the plane of scattering [3]. The cross section is chosen based on the results shown in the following sections, as 3.5mm (electrode spacing) x 7.8mm (optical depth). This is large enough to tolerate commonly found flow rates but at low enough velocity past the detection volume that the measurement is not effected over the target size range, but small enough that optical depth allows the measurement of electrophoretic mobility of high concentration samples at the forward angle. The cell is capable of being operated at up to 10 bar and has removable windows for cleaning and an embedded temperature probe capable of monitoring the temperature to within +/- 0.1 Celsius. The plunger on the cell top operates a cleaning wiper inside the cell used to remove contamination from both the windows and electrodes. * The reference and detected beams are actually interfered at the detector in the instrument. Showing the fringes created within the sample is physically equivalent and more instructive. Cleaning plunger Measurement Window Inlet pipe Figure 2 – The cell – prior to fitting into the unit The conductivity is measured using a high frequency field technique, used in order to avoid the build up of back EMF effects, and testing has shown the technique accurate to within +/- 10% up to 200mS/cm This is adequate for many applications. 2.3 INTERFACING & CONTROL The driver software is loaded onto a computer running Windows 2000/XP/Vista and the computer connected to the unit via a USB cable. It is likely that the detector will form part of some larger controlled system, e.g. a reactor & stirrer ,a pump, a dilution loop for very high concentration applications, for instance. With this in mind, the Zetasizer driver software is COM client enabled so that an external control system can maintain complete and live control over the instrument. All relevant functions of the software suite are exposed to the COM interface so that the unit can be enabled, the measurement sequence defined and run and the subsequent data mined for analysis by the server application, such as Labview TM, for instance. The software driver can be operated as a fat or thin client. For instance a single standard operating procedure (SOP) can be invoked or indeed an entire playlist (a pre-defined list of SOPs and macro’s), in order, for example, to measure size and zeta immediately after each other under the control of the instrument rather than the server application. 3. CHARACTERISATION – SIZE In this section we discuss the measurements taken of particle size using samples of various sizes and over a range of flow rates. The pump used was an Äkta chromatography pump capable of flow rates up-to 10.000ml/min to a precision of 0.001ml/min.
Details
-
File Typepdf
-
Upload Time-
-
Content LanguagesEnglish
-
Upload UserAnonymous/Not logged-in
-
File Pages8 Page
-
File Size-