A Concise Systematic Review on Liquid Chromatography

A Concise Systematic Review on Liquid Chromatography

INTERNATIONAL JOURNAL OF PHARMACEUTICS & DRUG ANALYSIS VOL. 3 ISSUE 9, 2015; 270 – 274 ; http://ijpda.com REVIEW ARTICLE Keywords: LC-MS/MS, Separation, Bioanalytical, Re- view. A CONCISE SYSTEMATIC INTRODUCTION: Liquid chromatography is a fundamental separation REVIEW ON LIQUID technique in the life sciences, pharmaceuticals and related fields of chemistry [1-3]. Unlike gas chromatography, which is unsuitable for nonvolatile and thermally fragile CHROMATOGRAPHY/ molecules, liquid chromatography can safely separate a very wide range of organic compounds from small- molecule drug metabolites to peptides and proteins. Mass MASS SPECTROMETRY spectrometers work by ionizing molecules and then sort- ing and identifying the ions according to their mass-to- WITH SPECIAL EMPHASIS charge (m/z) ratios [3-7]. Two key components in this process are the ion source, which generates the ions and the mass analyzer which sorts the ions. Several different ON ITS APPLICATIONS types of ion sources are commonly used for LC/MS. Each is suitable for different classes of compounds. Each has advantages and disadvantages depending on the type of Ravi Ranjan Kumar and Bansode Deepali * information needed [7-11]. INSTRUMENTATION Department of Pharmaceutical Chemistry, Bharati Vidya- ll mass spectrometers have three basic components: peeth University, Poona College of Pharmacy, Pune, Ma- a) Ionization source b) Mass analyzer & c) Detector harashtra, India-411038. a) Ionization source: Date Received: 14th August 2015; Date Accepted: 30th August Much of the advancement in LC/MS over the last ten 2015 Date published: 11 th September 2015 years has been in the development of ion sources and techniques that ionize the analyte molecules and separate Correspondance: [email protected] the resulting ions from the mobile phase. Earlier LC/MS systems used interfaces that neither did not separate the Abstract : Background: Mass spectrometry (MS) is a mobile phase molecules from the analyte molecules (di- wide-ranging analytical tool, which involves the pro- rect liquid inlet, thermospray) nor did so before ioniza- duction and subsequent separation and identification of tion (particle beam). The analyte molecules were then charged species. MS provides valuable information of molecular mass, molecular structural information and ionized in the mass spectrometer under vacuum, often by quantitative data all at high sensitivity. However, it is traditional electron ionization. These approaches were best separation techniques applied to complex mixtures successful only for a very limited number of compounds before mass spectrometry is undertaken. Liquid chro- [11-15]. Various types of ion sources are available in mass matography (LC) is excellent for separating mixtures spectrometry, which are listed and compared in Table 1. but generally poor at identification of compounds. It is The applications of various ionization techniques used in an arrangement of two or more mass spectrometers tan- mass spectrometry are explained in Fig. 1. dem-in-space and time placed one behind the other. Literature reveals many analytical approaches with de- tection systems, automation tools for an effective separa- b) Mass analyzer tion, enhanced selectivity and sensitivity for quantita- It is defined as a separation filter which can separate ions tion of many analytes. The bioanalytical method (s) de- by mass or more precisely by momentum or energy in velopment plays an important role during the process of space or in time. The separation can be achieved by the drug discovery and development culminating in a mar- use of combination of electric and magnetic fields and keting approval. The intention of this review is to cover sometimes radio frequeny (RF) fields [16-20]. The com- various key areas where LC/MS/MS shows its applica- monly use mass analyzers are following types: bility in bioanalytical areas. - Magnetic Sector Mass Analyser 270 Ravi Ranjan Kumar et al, Int J. Pharm. Drug. Anal , Vol: 3, Issue: 9, 2015; 270-274 Available online at http://ijpda.com - Time-of-Flight (TOF) Mass Analyser ion beam are accelerated to next dynode where each of - Quadruple Mass Analysers the electrons causes generation of two more electrons. The - Fourier Transform Ion Cyclotron Resonance same thing happens with third dynode and so on. (FT-ICR) Mass Analyser 2. Scintillator Detector or ('Daly' detector) Each mass analyzer is having its own characteristic and Here electrons are emitted due to fast ions and those are specificity. There are various types of mass analyzer are accelerated toward a second dynode which is made of a available which are shown in Fig. 2. Apart from above scintillator (which emits light or photons) and that emis- discussed four types of mass analyzers, there are also a sion is detected converted into an electric current by a large number of other variations which include hybrid photomultiplier tube. Good amplification even due to a systems. Hybrid ones are composed of two of the basic single ion appearance may be achieved using this detector types of mass spectrometer to make the system more spe- due to its high sensitivity. It is also helpful for metastable cific and accurate [21-23]. ion studies. 3. Faraday Cup Detector c) Detector Here secondary electron ejection is caused due to the The use of detector is the measurement of the ions which strike of the high speed travelling ions inside of a metal are leaving the mass analyzer [24-26]. Various types of built cup also known as Faraday cup. A temporary flow of mass detectors used in LC-MS/MS are as follows: current is initiated due to the production of electrons until 1. Electron Multipliers Detector they are recaptured. Advantages of Faraday cup detector It emits electrons from first dynode caused by incident are its simplicity and robustness but it is less sensitive. Table 1: Various types of ion sources Ionization method Type of ion formed Analytes Sample intro- Mass Method type duction limit Electron impact (EI) M+. M - small volatiles GC, liquid or 10 3 Hard method solid probe Chemical ionization(CI) - Electro-spray io- [M+nH]n +, peptides, pro- LC or 2 x10 5 soft method nization (ESI) [M– nX]n – teins syringe soft method [M +H] +, nonvolatile LC or 2x10 3 soft method - Atmospheric + pressure chemi- [M + X] small volatiles syringe less cal ionization M + polar species L 2x10 3 (APCI) hv _M+ small volatiles C or syringe - Atmospheric polar/non po- pressure photo lar ionization (APPI) Field ionization / desorp- [M +H] +, FI: volatiles GC, liquid 2 soft method tion [M + X] + FD: nonvola- or x 10 3 (FI/FD) tiles solid probe 271 Ravi Ranjan Kumar et al, Int J. Pharm. Drug. Anal , Vol: 3, Issue: 9, 2015; 270-274 Available online at http://ijpda.com Fig.2: Types of mass analyzers APPLICATION of LC/MS/MS 3. Pharmaceutical: The main use for LC/MS/MS in The evolution of LC/MS/MS from the early LC/MS in- the pharmaceutical industry has been in biologi- struments has revolutionized vast segments of analytical cal samples. The determination of target drug chemistry that deal with trace level contamination. The and metabolites in plasma and urine are critical initial problems of interferences are reduced significantly for the evaluation of new drugs. The LC/MS/MS by the tandem arrangement. The growth encompasses a is also used for the analysis of impurities in drug wide range of research areas, including: Food Safety, En- substances, and it has become valuable for the vironmental Protection, and Pharmaceutical Development detection of extractables and leachables in the [27-34]. Much of this is due to the advancements in the packaging industry. instrumentation (primarily in the interface between the LC and the MS and the implementation of atmospheric CONCLUSION pressure ionization), which have improved the sensitivity Liquid chromatography-tandem mass spectrometry offers and the selectivity of the technique to that unmatched by analytical specificity superior to that of immunoassays or most other analysis methods. conventional high performance/pressure liquid chroma- tography (HPLC) for low molecular weight analytes and 1. Environmental Applications: Because of the con- has higher throughput than gas chromatography-mass cern at even part per trillion levels for some of spectrometry (GC-MS). Because scientists are concerned pharmaceutical residues, veterinary medicine re- about lower and lower levels of detection for compounds sidues, and pesticides as well as metabolites of in complex matrices, an expansion in the prevalence of these products, LC/MS/MS has factored heavily the development of LC/MS/MS methods can be expected in this research area, which is expected by many as can an increase in the availability of the service to grow rapidly in the next decade. throughout the analytical industry. 2. Food Safety: The FDA has published several me- thods using LC/MS/MS for the determination of ACKNOWLEDGEMENT trace residues of contaminants in food products, The authors would like to thank, Dr. K.R. Mahadik, Prin- many of which have been traced to imported cipal, Poona College of Pharmacy, Pune for providing foods. Because of the need to detect very low le- necessary facilities. vels of the compound, LC/MS/MS is the pre- ferred analytical technique. 272 Ravi Ranjan Kumar et al, Int J. Pharm. Drug. Anal , Vol: 3, Issue: 9, 2015; 270-274 Available online at http://ijpda.com REFERENCES bolism studies. Journal of Mass Spectrometry, 2003; 1. Lee, M. S., & Kerns, E. H. (). LC/MS applications in 38(4), 357-372. drug development. Mass Spectrometry Re- 16. Olah, T. V., McLoughlin, D. A., & Gilbert, J. D. The views, 1999; 18 (3-4), 187-279. simultaneous determination of mixtures of drug 2. Covey, T. R., Lee, E. D., Bruins, A. P., & Henion, J. candidates by liquid chromatography/atmospheric D. Liquid chromatography/mass spectrome- pressure chemical ionization mass spectrometry as try. Analytical chemistry. 1986; 58(14), 1451A-1461 an in vivo drug screening procedure.

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    5 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us