
View metadata, citation and similar papers at core.ac.uk brought to you by CORE provided by Scientific Repository of the Polytechnic Institute of Porto Dionsia Castro Klara Slezakova Maria Teresa Oliva-Teles Cristina Delerue-Matos Analysis of polycyclic aromatic hydrocarbons in Maria Concei¼o Alvim- Ferraz atmospheric particulate samples by microwave- Simone Morais assisted extraction and liquid chromatography Maria Carmo Pereira A methodology based on microwave-assisted extraction (MAE) and LC with fluores- cence detection (FLD) was investigated for the efficient determination of 15 polycy- clic aromatic hydrocarbons (PAHs) regarded as priority pollutants by the US Envi- ronmental Protection Agency and dibenzo(a,l)pyrene in atmospheric particulate samples. PAHs were successfully extracted from real outdoor particulate matter (PM) samples with recoveries ranging from 81.4 l 8.8 to 112.0 l 1.1%, for all the com- l l pounds except for naphthalene (62.3 18.0%) and anthracene (67.3 5.7%), under the optimum MAE conditions (30.0 mL of ACN for 20 min at 1108C). No clean-up 3 steps were necessary prior to LC analysis. LOQs ranging from 0.0054 ng/m for ben- 3 zo(a)anthracene to 0.089 ng/m for naphthalene were reached. The validated MAE methodology was applied to the determination of PAHs from a set of real world PM samples collected in Oporto (north of Portugal). The sum of particulate-bound PAHs 3 in outdoor PM ranged from 2.5 and 28 ng/m . Keywords: Atmospheric particulate samples / Liquid chromatography / Microwave-assisted ex- traction / PAHs / PM / 1 Introduction transport through the atmosphere making them a trans- boundary environmental problem [1]. Polycyclic aromatic hydrocarbons (PAHs) are ubiquitous Particulate matter (PM), which is a mixture of sus- environmental pollutants [1] and some of them are pended particles and aerosols, can lead to health prob- human genotoxic carcinogens [2]. PAHs are produced lems and even premature mortality. Recent research mainly by high-temperature reactions, such as incom- studies seem to indicate that PM with aerodynamic diam- plete combustion and pyrolysis of fossil fuels and bio- eter less than 10 micrometers (PM10) are associated with masses [3, 4]. Major sources of PAHs in urban areas respiratory responses and PM with aerodynamic diame- include automobile traffic, domestic heating, thermal ter less than 2.5 micrometers (PM2.5) mainly with cardio- power stations, and industrial emissions [5]. After forma- vascular diseases [6]. Nevertheless, it is not yet clear if it is tion and emission, partition of these compounds the physical or the chemical PM characteristics, or both, between the gaseous phase and the atmospheric aerosols that are responsible for these effects [6]. Most of the PAHs occurs. Their semi-volatile nature makes them highly with low vapor pressure in the air are adsorbed onto PM mobile throughout the environment, with deposition [7]. and revolatilization process distributing them between Benzo(a)pyrene is the marker used for the carcinogenic air, water and soil. Some PAHs are subject to long-range risk of PAHs in ambient air [1]. Recently and with the aim of minimizing harmful effects on human health and the environment as a whole of airborne PAH, the European Abbreviations: ACN, acetonitrile; FLD, fluorescence detection; Union defined a target value for benzo(a)pyrene: 1 ng/m3 MAE, microwave-assisted extraction; PAHs, polycyclic aromatic for the total content in the PM fraction averaged over a hydrocarbons; PM, particulate matter; SRM, standard reference 10 material calendar year [1]. However, the suitability of benzo(a)pyr- ene as an indicator of carcinogenic PAHs has been ques- tioned by new findings on the presence of more potent PAHs such as dibenzo(a,l)pyrene [8]. It has been estimated to have a carcinogenic potency that is approximately 100 times that of benzo(a)pyrene [9]. Until now, however, works that include the determination of dibenzo(a,l)pyr- ticles were collected on PTFE membrane filters with ene in PM are limited [10]. 2 lm porosity [20]. The extraction of PAHs from atmospheric PM can be Samples were stored at –208C and were protected achieved with a number of established methods [11, 12]. from light. Optimal conditions of MAE were applied to Microwave-assisted extraction (MAE) provides a tech- analysis of outdoor PM samples (PM10 and PM2.5), collected nique where compounds can be extracted selectively, in under the same above conditions, from 17 to 25 February a relatively short period of time compared to conven- 2008 in Oporto (Portugal). tional extraction methods and allows for an enhanced extraction yield for the more volatile compounds which 2.2 Reagents and materials normally require special and separate extraction meth- ods [13, 14]. This approach supports sustainable develop- Certified “EPA 16 PAHs” standard mixture and an indi- ment as it permits the use of lower toxicity solvents, and vidual standard of dibenzo(a,l)pyrene (DB(a,l)P) 2000 lg/ requires less energy and solvent than conventional proc- mL were purchased from Supelco, Bellefonte, PA, USA. esses, while generating fewer wastes [14]. Several authors The certified standard mixture included naphthalene explored the possibility of utilizing MAE for the extrac- (Naph) 1000 lg/mL, acenaphthylene (Aci) 2000 lg/mL, tion of PAHs from environmental materials [15]. In this acenaphthene (Ace) 1000 lg/mL, fluorene (Flu) 199.9 lg/ study, a systematic investigation on the application of mL, phenanthrene (Phe) 99.8 lg/mL, anthracene (Ant) MAE and LC with fluorescence detection (FLD) for the 100.0 lg/mL, fluoranthene (Fln) 200.1 lg/mL, pyrene determination of 15 PAHs regarded as priority pollutants (Pyr) 99.9 lg/mL, benzo(a)anthracene (B(a)A) 100.1 lg/mL, by the US Environmental Protection Agency (US EPA), chrysene (Chry) 100.0 lg/mL, benzo(b)fluoranthene and dibenzo(a,l)pyrene in airborne PM samples was per- (B(b)Ft) 200.2 lg/mL, benzo(k)fluoranthene (B(k)Ft) formed. Comparing to previous related MAE works [16 – 99.9 lg/mL, benzo(a)pyrene (B(a)P) 100.0 lg/mL, diben- 19], only environmental friendly solvents were tested, zo(a,h)anthracene (DB(a,h)A) 200.0 lg/mL, benzo(g,h,i)- dibenzo(a,l)pyrene was studied and the parameters eval- perylene (B(g,h,i)P) 200.0 lg/mL, and indeno(1,2,3-cd)pyr- uated include the temperature instead of the microwave ene (InP) 100.1 lg/mL. Working mixed standard solu- power. The power is less interesting to control since it tions containing all the PAHs were prepared by dilution depends on the number of samples to be extracted at one of the stock solutions with ACN and stored at –208Cin time and if it is not adjusted accordingly, different tem- darkness to avoid volatilization and photodegradation. peratures will be reached in each run compromising The standard reference material (SRM) 1650b (diesel extraction efficiency (in modern apparatus 14 –40 sam- PM) was provided by the National Institute of Standards ples can be simultaneously extracted). Also, the devel- and Technology (NIST; Gaithersburg, MD, USA). oped procedure avoids the need for extract clean-up steps Acetone (purity 99.8%; Riedel-de Han, Seelze, Ger- before instrumental analysis. many), ACN Lichrosol for gradient elution (purity A99.9% For this work, outdoor PM samples from Oporto (north Carlo Erba, Rodano, Italy), methanol Lichrosol. For gra- of Portugal) were collected in PTFE membrane filters for dient elution (purity 99.9%; Riedel-de Han) and n-hexane sampling periods of 12 and 24 h. Usually quartz or glass Chromasolv (Merck, Darmstadt, Germany) were used. fiber filters are used but these filters require a preheating Ultra-pure water was prepared by a Milli-Q simplicity at 4008C for 24 h prior to use in order to reduce their 185 system (Millipore, Molsheim, France). water and organic matter blank values [19]. The PTFE fil- The glassware was washed with detergent and water, ters do not require this pretreatment and are appropri- rinsed with acetone and n-hexane and dried at 908C ate to PM sampling at a low air flow and sampling time. before use. 2.3 Microwave-assisted extraction 2 Material and methods MAE experiments were performed with a MARS-X 1500 W Microwave Accelerated Reaction System for 2.1 Sampling Extraction and Digestion (CEM, Mathews, NC, USA) con- For MAE optimization studies, PM sampling was per- figured with a 14 position carousel. During operation, formed in the city of Oporto, north of Portugal, at one both temperature and pressure were monitored in a sin- site directly influenced by traffic emissions. The collec- gle vessel. Magnetic stirring in each extraction vessel and tion of the different PM fractions was performed using a sensor registering the solvent leaks in the interior of TCR TECORA Bravo H2 constant flow samplers (with flow the microwave oven were also used. 3 rate 2.3 m /h) combined with PM10 and PM2.5 EN LVS sam- For optimization studies, each membrane filter after pling heads in compliance with norm EN12341 [20] and sampling was cut into two parts having, as much as possi- no more than 24 h of sampling by each filter. The par- ble, the same size which were accurately weighted. One Table 1. Spiking range tested for each PAH was used as the mobile phase and different solvent gra- dient programs were tested to reduce the analysis time l a) Compound Spiking range ( g/g) while keeping a good resolution of all PAHs studied. The Naphthalene 0.916–2.05 following chromatographic conditions were selected: Acenaphthene 1.07–2.63 initial conditions 45:55 ACN/water, then a linear ramp to Fluorene 0.196–0.420 100% ACN in 15 min, holding this condition during Phenanthrene 0.110–0.232 7 min.
Details
-
File Typepdf
-
Upload Time-
-
Content LanguagesEnglish
-
Upload UserAnonymous/Not logged-in
-
File Pages10 Page
-
File Size-