™ Triple Action Humidifier Model: AW600 Thank you for purchasing this WINIX product •Read and follow all safety rules and instructions before operating this equipment. •Please keep this manual for future reference. Triple Action Humidifierwith Winix HumidiPür™ Triple Action Humidifier simultaneously humidifies HumidiPür™ and cleans the air. Featuring a 3.17 gallon per day humidification Model: AW600 capacity and 3-Stage air purification with PlasmaWave® Technology. ® ® Mist Humidifier PlasmaWave technology removes air HumidiPür™ generates very fine and light mist pollutants resulting in cleaner fresher to enhance consistent humidity level. air. Auto Mode CleanCel® Anti-Bacterial Coating WINIX’s sensor detecs room humidity HumidiPür™ has been treated with CleanCel® level to control fan speed and optimize antibacterial coating to prevent growth of the humidity level. bacteria in the water tank and cleaning discs. Timer Auto Shut-Off The automatic Timer indicator is used Automatically shuts off when the water bucket to maintain efficiency throughout the is Low. lifetime of the product. Sleep Mode Light sensor detects when the room is dark and adjusts the unit to Sleep Mode to reduce power consumption. 1 Table of Contents Safety Instructions Warning 3 Product Information Unit Diagram 11 Control Panel/Display 12 Installation Selecting a Location 13 Set-Up Instructions 14 Operation Modes of Operations 15 Care and Maintenance 19 Troubleshooting FAQ/Solutions 25 Product Specifications 27 2 Safety Instructions Warning PROHIBITED Follow these instructions to avoid any risk of personal injury, property damage, DO NOT DISASSEMBLE electrical shocks or fire hazard. Notice MUST FOLLOW Failure to follow the safety instructions can lead to personal injury or property Ground connection protecting damage. from electrical shock Warning DON’T unplug the unit by pulling on DON’T touch the plug with wet hands. it’s power cord. DON’T bend or place heavy object on DON’T replace or modify power cord. the power cord. If the power cord/plug is damaged, it must be replaced by the manufacturer or a qualified technician. 3 Warning DON’T plug multiple power plugs into DO connect the power cord to only an outlet. Plug directly into the wall. proper power outlet with a ground connection. DO unplug the HumidiPür™ when not DON’T plug power cord into loose or in use to save on energy consumption. damaged electrical outlet. (This can lead to overheating or electrical shock) DON’T attempt to repair, alter or DON’T operate the unit if standing dissasemble the unit. water is present. 4 Safety Instructions NotNotee DON’T operate HumidiPür™ DON’T spray liquids directly into on an uneven surface. air washer. DON’T place the HumidiPür™ near DON’T place the unit on an flammable material (such as gas, unstable place such as a table aerosols, or benzene). or a sink. Attempt to change the bucket and DON’T pour water into the top refill with clean water every day. of the air unit, place in water tank as directed. 5 Note DO unplug the unit and contact DON’T insert ANYTHING into the your service dealer if the unit air inlet or outlet. comes in contact with water. DON’T remove the water tank if DON’T install the unit in the place full a child is nearby. of high humidity or dust. DO unplug the unit and contact your DON’T place anything around the unit service dealer if it is sunken under to allow children to play or sit on. water. 6 Safety Instructions Note DON’T disconnect the DO unplug the appliance DO unplug the unit and power cord during during filling and cleaning. contact your service operation. dealer if any irregular noise or smoke occurs. DO use the HumidiPür™ DON’T insert anything into DON’T place the unit after assembling the the air inlet or outlet. near a heat source. Antimicrobial Disk. DON’T place hands or DON’T place the unit DON’T strike or drop any body parts near near curtains or other the unit. the air outlet during materials that can block operation. the vents of the unit. 7 Note DON’T allow children to DON’T use hot water in DO clean Antibacterial plplayay on or near the unit. the water tank. disk regularly with warm tap water and allow to air dry. DON’T spray flammable DON’T lift the unit by DON’T use flammable liquids or gases into the the top. material (such as benzene unit. or alcohol) to clean the unit. DON’T install the unit DON’T place clothes and DON’T spray liquids under direct light. towels on top of air directly washer while operating. into HumidiPür™ during cleaning. 8 Safety Instructions Note DON’T install the unit DON’T put the unit near After cleaning, allow near the wall or window. burning cigarette or Antibacterial Discs, incense. water tank, and pre-filter to air dry completely. DON’T operate the unit DON’T allow water to DON’T operate the while insecticide is used. stay in the water tank for unit while water tank a long time while not in is damaged. use. DON’T install the unit DON’T drink the water DON’T put the unit near whose airflow outlet is left in the water tank or a microwave oven or facing the wall. give it to plants or TV. animals. 9 Note DON’T overfill the water DON’T put the unit near DON’T plug in if the tank. ceilings, walls, furniture, power plug is touched or electronic appliances. with water. DO dispose of the water DON’T lift the unit with DON’T put magnet or to prevent it from freezing water still in the water metal material on the in cold weather. tank. top of the unit. DO unplug the unit and DO clean the air washer DO use clean tap water move its water tank when regulary, with a microfiber without detergent, soap, water is removed. towel or any other clean chemical compounds or wiping material. hot water (over 104ºF). 10 Product Diagram Front Panel Anti-bacterial Disc (CleanCel®) Anti-bacterial Disc Handle Water Level Indicator Anti-bacterial Water Tank (CleanCel®) Water Tank Release Lever Control Panel Display Air Outlet Cover Air Outlet Fan (inside) Air Outlet Release Button HEPA + Carbon Comination Filter Air Intake Power Plug 11 Control Panel Function Button 1. Continuous Mode Unit operates continuously on the fan speed selected by user (Low/Mid/High) regardless of ambient humidity. 2. Sleep Mode Dims control panel lights and sets the unit to operate at lowest fan speed. 3. Auto-Mode Unit runs until ideal humidity level is reached and shuts off intermittently to save energy (Green “Comfort Zone”). Timer Setting Button Low Water Power Indicator Mode PlasmaWave® Timer Indicator (ON/OFF Indicator) Indicator Fan Speed Control Panel Indicator Low High Lock Indicator Humidity Humidity Indicator Indicator Fan Speed Button PlasmaWave® PlasmaWave® (Low, Medium, High) (ON/OFF Button) (ON/OFF Indicator) Humidity Level Indicator Displays humidity level, when desirable level of humidity levels are reached they will be displayed in the green “Comfort Zone” Orange -> Low Humidity (Below 30% RH) Blue -> High Humidity (61-70% RH) Green -> Ideal Humidity (40-60% RH) 12 Installation Selecting a Location 4 inches 1515 inches Do not install the unit under direct sunlight. - Long Exposure to direct sunlight can cause defects. HumidiPür™ must be installed and operated on an even surface. - Vibrations and noise can occur on soft or non-flat surfaces. Product must be Installed approximately 10cm/ 4 inches away from the wall and 30-40cm/ 15 inches from other electronic appliances. Before operating the HumidiPür™, remove any plastic bags and polyfoams from outside and inside the unit. 13 Operation Set-Up Instructions 1. Slide water tank out, by using the release lever located below the water tank on the front of the unit. 2. Fill the water tank with cool tap water up to the indicator line on the inside of water tank. 3. Replace the water tank by sliding it back into the unit until you hear it click into place. 4. Gently slide down the front panel and make sure that it is seated properly and lines up correctly. Make sure to unplug the power cord before filling the unit with water. We recommend using filtered water to prolong the life of the product. Use cautions when moving the unit filled with water. 14 Operation Before Turning On Plug the power cord into a power 1 outlet. Push the POWER button. 2 The unit will start on AUTO 3 MODE and the PlasmaWave® function will be ON. A soft buzzing or clicking sound may occur during operation; if this is uncomfortable, you can turn off the PlasmaWave® feature by using the PlasmaWave® ON/OFF button. 15 Auto Mode Push FUNCTION button to select 1 Auto Mode AIR FLOW: When ambient humidity is sensed at less that 60%, the unit will operate at “High” fan speed. When the ambient humidity is sensed at greater than 60% the unit will operate at “Low” fan speed. CLEANING DISCS: When ambient humidity is sensed at greater than 75% humidity the cleaning discs will stop spinning. When ambient humidity is sensed less than 60%, the disc, resumes to circulate. Continuous Mode Push the FUNCTION button to select 1 Continuous Mode. - Continuous Mode Indicator will illuminate. - The FUNCTION button will cycle the unit between the following: Auto -> Continuous -> Sleep 16 Operation Sleep Mode Push the FUNCTION button to select 1 Sleep Mode. The MODE button will cycle the unit between the following: Auto -> Continuous -> Sleep During Sleep Mode the unit will set fan 2 speed to lowest setting and the display will turn off, except for the low fan speed indicator.
Details
-
File Typepdf
-
Upload Time-
-
Content LanguagesEnglish
-
Upload UserAnonymous/Not logged-in
-
File Pages30 Page
-
File Size-