BCD-ALE-OS6900 Series

BCD-ALE-OS6900 Series

Distributed by BCD-ALE-OS6900 Series Data Sheet Enterprise 1U SFP+/QSFP+ Layer 3 Network Switch High Density, Maximum Performance Enterprise 1U Rackmount 10GbE to KEY FEATURES 40GbE Network Switches • 20 SFP+ and 48 10GbE SFP+ with 6 40GbE QSFP+ configurations For mission critical projects requiring top of the line networking features, • Shortest Path Bridging for high availability the BCD-ALE-OS6900 series provides the performance and resiliency • Hot swappable power supplies and fans needed. With both 10GbE and 40GbE, SFP+ and QSFP+ configurations, • Resilient hardware system structure for these network switches offer extremely high throughput that is required greater network stability for the most demanding video surveillance projects. The BCD-ALE- OS6900 series offers mission critical features, including Extensible LAN (VXLAN), Shortest Path Bridging (SPB), QoS, and Layer-2 and Layer-3 switching in addition to network and system resiliency. • Enable maximum network performance with throughput rates up Up to 72 Total SFP+ and QSFP+ Ports to 1.4Gp/s, switching capacity of 1.44Tb/s, a data buffer of 12MB, and a sub 650ns latency. 1.4Gp/s Throughput and • IEEE 802.1aq Shortest Path Bridging enables high network 1.44Tb/s Switching Capacity availability and maximum use of all physical connections and 3-Year, 24/7 Support with routed services. Advanced Next-Day Replacement • Out of the box simplicity is provided with automated provisioning and the ability to manage multiple switches at once. • Reliability is provided through power supply and fan redundancy, as well as smart continuous switching technology. BCD-ALE-OS6900-X72F BCD-ALE-OS6900-X20F FOR MORE INFORMATION: bcdvideo.com | [email protected] | +1.847.205.1922 TECH SUPPORT: [email protected] | +1.844.462.2384 Copyright © 2018, BCDVideo. All rights reserved. This document is provided for information purposes only. The contents are subject to change without notice. 18A BCD-ALE-OS6900 R1 Distributed by BCD-ALE-OS6900 Series Data Sheet Enterprise 1U SFP+/QSFP+ Layer 3 Network Switch SYSTEM Maximum Number of Ports 72 Total Ports, (48) SFP+, (6) QSFP Management Ports Up to (1) RJ45 Ethernet Management Port and (1) Console Management Port Flash 4GB Memory 8GB Data Buffer 12MB Max Switching Capacity 1.44Tb/s non-blocking Throughput 1.4Gp/s Latency <650ns Expansion Slots (1) Warranty 3-Year, 24/7 Support with Advanced Next-Day Replacement MECHANICAL Form Factor 1U Rackmount Maximum Power Consumption Up to 242W Power Supply(s) (2) 450W | 100-240VAC Heat Dissipation Up to 825 BTU/h Operating Temperature (Min) 32°F - (Max) 113°F [(Min) 0°C - (Max) 45°C] Operating Humidity 5 ~ 95% Non-condensing Dimensions (WxDxH) 17.06" x 22" x 1.73" (433mm x 559mm x 44mm) Max. Weight 23.05 lbs (10.86 kg) Regulatory FCC 47 CFR Part 15 Class A, ICES-003 Class A, CE, EN55022:1998:2006 Class A, EN55024 :1998:A1: 2001+A2:2003, EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11, CISPR22:1997 Class A IEEE Standards IEEE 802.1D STP IEEE 802.1p CoS IEEE 802.1Q VLANs IEEE 802.1ad Provider Bridges Q-in-Q/ VLAN stacking IEEE 802.1ak (MVRP) IEEE 802.1aq Shortest Path Bridging (SPB) IEEE 80.1ab LLDP IEEE 802.1ag OAM IEEE 802.1Qaz ETS/DCBX IEEE 802.1 CEE 1.01 IEEE 802.1Qbb PFC IEEE 802.1s MSTP IEEE 802.1w RSTP IEEE 802.1X Port-based Network Access Control (PNAC). IEEE 802.3x Flow Control IEEE 802.3u Fast Ethernet IEEE 802.3z 1 GigE IEEE 802.3ab 1 GBASE-T IEEE 802.3ac VLAN Tagging IEEE 802.3ad/802.1AX Link Aggregation IEEE 802.3ae 10 GigE IEEE 802.3an 10 GBASE-T IEEE 802.3az Energy Efficient Ethernet (EEE) IEEE 802.3ba 40 GigE IEEE 802.1x-2004 IEEE 1588-2008 (PTP) FOR MORE INFORMATION: bcdvideo.com | [email protected] | +1.847.205.1922 TECH SUPPORT: [email protected] | +1.844.462.2384 Copyright © 2018, BCDVideo. All rights reserved. This document is provided for information purposes only. The contents are subject to change without notice. 18A BCD-ALE-OS6900 R1 Distributed by BCD-ALE-OS6860 Series Data Sheet Enterprise 1U RJ45/SFP Layer 3 Network Switches High Performance and High Availability KEY FEATURES Enterprise Multigigabit and 10GbE 1U Rackmount PoE+ Network Switches • 24 PoE, 48 PoE, and 28 GbE SFP Port configurations • Shortest Path Bridging provides high availability The BCD-ALE-OS6860 multigigabit and 10GbE PoE+ network switches • Hot-swappable power supplies are powerful and versatile to fulfill a range of purposes. With advanced • Resilient hardware system structure for greater security features including IEEE 802, 1AE MACSec encryption to secure network stability the edge of a network, this network switch takes on whatever task it needs to complete. With a vast PoE budget of 1500W, as well as up to 48 gigabit ports, this switch can be deployed as an edge switch or a core switch for a small network. • Provide high-end network performance with 264Gb/s raw fabric capacity, 256Gb/s switching capacity, and a throughput of Up to 48 Total Gigabit Ports 190.6Mpps with a 64-byte packet. with 4 SFP+ Uplink Ports • IEEE 802.1aq Shortest Path Bridging (SPB) enables high network 264Gb/s Raw Fabric Capacity and availability and maximum use of all physical connections and 256Gb/s Switching Capacity routed services. Up to 1500W of PoE+ power • IEE 802.3af and 802.3at compliant 30W of PoE+ on all ports provides high density power to multiple video surveillance cameras. 3-Year, 24/7 Support with Advanced Next-Day Replacement Onboard advanced hardware helps optimize video data transfer. • High availability and network optimization features include redundant power supplies and application monitoring. BCD-ALE-OS6860E-P24 BCD-ALE-OS6860E-P48 FOR MORE INFORMATION: bcdvideo.com | [email protected] | +1.847.205.1922 TECH SUPPORT: [email protected] | +1.844.462.2384 Copyright © 2018, BCDVideo. All rights reserved. This document is provided for information purposes only. The contents are subject to change without notice. 18A BCD-ALE-OS6860 R1 Distributed by BCD-ALE-OS6860 Series Data Sheet Enterprise 1U RJ45/SFP Layer 3 Network Switches SYSTEM Maximum Number of Ports (48) PoE, (4) 1G/10G SFP+ or (28) SFP, (4) SFP+ MACSec Capable Ports (4) 10G SFP+ Up to (1) RS-232 and (1) Console Management Port, Management Ports (1) Ethernet Management Port on BCD-ALE-OS6860E-U28 Total PoE Budget 1500W with (2) 920W power supplies PoE per Port Up to 75W per port Total number of IPv4 Routes 64,000 Max Raw Fabric Capacity 254Gb/s Max Switching Capacity 256Gb/s Throughput 190.6Mpps (64-byte packet) File System Flash 2GB RAM 2GB Total MAC Addresses 48,000 Warranty 3-Year, 24/7 Support with Advanced Next-Day Replacement MECHANICAL Form Factor 1U Rackmount Maximum Power Consumption Up to 900W Power Supply(s) Up to (2) 920W | 100-240VAC Heat Dissipation Up to 241.6 BTU/h Operating Temperature (Min) 32°F - (Max) 113°F [(Min) 0°C - (Max) 45°C] Operating Humidity 5 ~ 95% Non-condensing Dimensions (WxDxH) 17.33" x 13.78" x 1.73" (440mm x 350mm x 44mm) Max. Weight 14.0 lbs (6.35 kg) Regulatory 47 CRF FCC Part 15: 2015 Subpart B (Class A) ICES–003:2012 Issue 5, Class A ANSI C63.4-2009 VCCI (Class A, with UTP Cables) AS/NZS 3548 (Class A) – C-Tick CE marking for European countries (Class A, with UTP Cables) CE EN 55032 (EMI & EMC) EN 55024 (Immunity) EN 50581 (RoHS Recast) EN 61000-3- 2 EN 61000-3-3 EN 61000-4-2 EN 61000-4-3 EN 61000-4-4 EN 61000-4-5 EN 61000-4-6 EN 61000-4-8 IEEE 802.3: Hi-Pot Test (2250 VDC on all Ethernet ports) IEEE Standards IEEE 802.1D STP IEEE 802.1p CoS IEEE 802.1Q VLANs IEEE 802.1ab (LLDP) IEEE 802.1ag (OA&M) IEEE 802.1ad Provider Bridges Q-in-Q/VLAN stacking IEEE 802.1ak (Multiple VLAN Registration Protocol (MVRP) IEEE 802.1aq Shortest Path Bridging (SPB) IEEE 802.1s MSTP IEEE 802.3i 10BASE-T IEEE 802.1w RSTP IEEE 802.3x Flow Control IEEE 802.3z Gigabit Ethernet IEEE 802.3ab 1000Base-T IEEE 802.3ac VLAN Tagging IEEE 802.3ad/802.1AX Link Aggregation IEEE 802.3ae 10 GigE IEEE 802.3af Power over Ethernet IEEE 802.3at PoE Plus IEEE 802.3az Energy Efficient Ethernet (EEE) IEEE 802.3bz 2.5/5 GigE IEEE 802.3ba 40GBASE-X IEEE 802.1x-2004 IEEE 802.1ae MAC Security IEEE 1588-2008 (PTP) FOR MORE INFORMATION: bcdvideo.com | [email protected] | +1.847.205.1922 TECH SUPPORT: [email protected] | +1.844.462.2384 Copyright © 2018, BCDVideo. All rights reserved. This document is provided for information purposes only. The contents are subject to change without notice. 18A BCD-ALE-OS6860 R1 Distributed by BCD-ALE-OS6560 Series Data Sheet Professional 1U RJ45 Layer 2 Network Switches High Efficiency Professional 24 to 48 KEY FEATURES Port Edge Network Switch with HPoE Capabilities for Enterprise Projects • 24 PoE ports and up to 24 2.5GbE HPoE ports • Dynamic PoE allocation Reliable and powerful, the BCD-ALE-OS6560 enables a highly effective • Multigigabit HPoE ports provide up to 75W of edge network switch solution with up to 24 gigabit ethernet ports and clean power 24 multigigabit ports. An immense 1730W of PoE+ power is provided by • Hot-swappable power supplies redundant power supplies, and is available to power a variety of network • Resilient hardware system structure for devices.

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    14 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us