Flow Cytometry Richard R

Flow Cytometry Richard R

RESEARCH TECHNIQUES MADE SIMPLE Flow Cytometry Richard R. Jahan-Tigh1,2, Caitriona Ryan3,4,5, Gerlinde Obermoser5 and Kathryn Schwarzenberger6 Journal of Investigative Dermatology (2012) 132, e1. doi:10.1038/jid.2012.282 Of the techniques available to both the clinician and the WHAT FLOW CYTOMETRY DOES researcher, few are as widely employed as flow cytometry. With applications that range from common clinical lab- • Flow cytometry is a sensitive, powerful method for oratory tests, such as complete blood count with differ- simultaneously obtaining information on various ential and monitoring of CD4 cell count in HIV patients, cellular processes, including expression of surface to advanced, multicolor flow cytometry used to identify markers, intracellular cytokine and signaling subtypes of inflammatory cells active in diseases such as proteins, or cell cycle. psoriasis and lupus, flow cytometry has become rapid, • Flow cytometry measures these characteristics on flexible, and sensitive. each cell individually in a high-throughput fashion and excels in characterizing heterogeneous cell THE FLOW CYTOMETRY PROCESS populations. Flow cytometry measures single cells “flowing” through • Flow cytometry is capable of sorting cells based on a detector system. The process begins with the selection almost any of the features it measures. of fluorescent-labeled antibodies specific to cell-surface markers used to characterize the cell population of inter- est. These cell surface markers are usually glycoproteins LIMITATIONS called cluster of differentiation (CD) markers, and they + + • Flow cytometry is limited by its requirement help differentiate cell subpopulations (e.g., CD3 CD8 for that analyzed cells be in suspension, making cytotoxic T cells). Flow cytometry can be performed on a information on tissue architecture and cell–cell variety of tissues, including peripheral blood, bone mar- interactions unavailable. row aspirates, skin biopsies, and tissue culture cell lines (Macey, 2007). The sample is processed, for example, • Cell subpopulations with similar marker expression with enzymatic degradation, centrifugation, and/or filtra- are difficult to differentiate and analyses that tion to isolate the cells of interest, and the resulting cel- employ more fluorophores are subject to signal lular suspension is “stained” with fluorescent antibodies. spillover. The single cell suspension is then introduced into the flow • Flow cytometry may generate massive amounts of cytometer into a cell-free buffer solution called the sheath data, making analyses complicated. fluid, which flows toward a laser aimed at the solution’s path. Because the flow of the liquid through the tubing is laminar, or sheet-like, and the diameter of the tubing nar- rows along its path, the cells are forced to line up single cal system that is sensitive to various wavelengths, allow- file as they approach the laser (Figure 1). The fluorescent ing for information on multiple surface markers to be read chemical bound to the antibody, called a fluorophore, is simultaneously and collected by an adjoined computer. chosen based on the specific wavelength of laser present Specialized software then can graphically represent the in each flow cytometer. If cells have the selected mark- distribution of the labeled cell populations in one-, two-, er on the surface, the bound antibody–fluorophore will or three-dimensional formats (Figure 2). absorb the laser energy and subsequently release it in A variety of fluorochromes are available that individu- the form of a specific wavelength of light as the cells pass ally emit light of specific, different wavelengths while through the laser. The emitted light is detected by an opti- absorbing light of the same wavelength. This is the basis 1Department of Dermatology, University of Texas Houston Medical School, Houston, Texas, USA; 2Department of Dermatology, University of Texas MD Anderson Cancer Center, Houston, Texas, USA; 3Department of Dermatology, Baylor University Medical Center, Dallas, Texas, USA; 4Menter Dermatology Research Institute, Dallas, Texas, USA; 5Baylor Institute for Immunology Research, Dallas, Texas, USA and 6Division of Dermatology, University of Vermont College of Medicine, Burlington, Vermont, USA Correspondence: Richard R. Jahan-Tigh, University of Texas Health Science Center at Houston, MD Anderson Cancer Center, 6655 Travis Street, Suite 980, Houston, Texas 77030, USA. E-mail: [email protected]; Gerlinde Obermoser, Baylor Institute for Immunology Research, Flow Cytometry Shared Resource Laboratory, 3434 Live Oak, Dallas, Texas 75204, USA. E-mail: [email protected] © 2012 The Society for Investigative Dermatology www.jidonline.org 1 RESEARCH TECHNIQUES MADE SIMPLE Figure 1. Schematic representation of a flow cytometer. For details please see text. (1) Forward-scatter detector, (2) side-scatter detector, (3) fluorescence detector, (4) filters and mirrors, and (5) charged deflection plates. Figure 2. Scatter plots displaying the FSC (X-axis) and SSC (Y-axis) of lysed whole peripheral blood. The FSC scatter data provide information on the relative size of the cells, whereas the SSC data estimate the granularity. Four ways of displaying identical data: (i) pseudocolor dot plot (allows simultaneous information of rare events (dots) and high-frequency areas with dots of different color), (ii) dot plot where each dot represents one event (note that here only 10,000 events are shown to avoid oversaturation of dots), (iii) 5% probability density plot, and (iv) 5% probability contour plot, where the density of a population is translated in varying shades of color or concentric rings of varying distance. Major leukocyte populations as defined by FSC and SSC properties are shown in (i). FSC-A, forward scatter area; RBC, red blood cells; SSC-A, side scatter area. 2 Journal of Investigative Dermatology (2012), Volume 132 © 2012 The Society for Investigative Dermatology RESEARCH TECHNIQUES MADE SIMPLE for polychromatic flow cytometry, and it allows for a flow FLOW CYTOMETRY DATA ANALYSIS cytometry sample labeled with different fluorochrome– In addition to the fluorescence data, optical information antibody complexes to be read simultaneously with one known as forward scatter (FSC) and side scatter (SSC) is pass through the laser. Because emission spectra of fluo- obtained based on the angle of light emitted from the ana- rochromes overlap to varying degrees, a single detector lyzed cell. Classically, FSC is light scattered at a small angle may see fluorescence originating from more than one and detected by a sensor on the opposite side of the 488- fluorochrome; this spillover must be removed using a nm/blue laser source (Figure 1). FSC essentially provides mathematical algorithm, so that one detector reports sig- information correlating with cell size. Light that scatters nal from only one fluorochrome. This process is called off the cell at a 90° angle, called “side-scatter,” is picked “compensation.” up by an adjacent series of sensors and provides informa- In addition to antibodies, fluorescent dyes are available tion on the granularity of the cell. This could be useful, for that label the plasma membrane, DNA, or, for example, example, when trying to distinguish between lymphocytes substrates for enzymes (e.g., apoptosis-inducing cas- and granulocytes. The scatter plot is one of the most basic pases or autophagy-related enzyme LC3). Thus, it is pos- means of visualizing flow cytometric data, and the informa- sible to simultaneously measure multiple parameters in a tion is plotted with the X-axis as FSC intensity and the Y-axis single cell by detecting cell-surface molecules defining as SSC intensity (Figure 2). The axes of the plots are labeled the lineage (CD3+CD4+ T-cell lymphocytes), activation with the name of the fluorochrome and the surface marker status (HLA-DR, CD38), phosphorylation status of signal (e.g., FITC–CD3 for fluorescein isothiocyanate–labeled CD3 transduction molecules (“phospho-flow”), intracellular cells). Cells positive for both markers will be located in the cytokine production, cell cycle phase (via DNA content), upper right quadrant, whereas cells negative for both will be viability, calcium flux, oxidative burst, etc. located in the bottom left quadrant (Figure 3). For the scatter dot plots the axes are linear, whereas in fluorescence plots, FLOW CYTOMETRIC CELL SORTING, “FLUORESCENCE- because of the wide range of fluorescence signals, they are ACTIVATED CELL SORTING” usually displayed logarithmically (Herzenberg et al., 2006). Cells of interest can be separated to very high purity (very “Gating” is the term used to describe the selection of a sub- often 99%) by cell-sorting flow cytometers. After cells population of cells for analysis. For example, if further char- are “interrogated” by laser light in the flow chamber, the acterization of only lymphocytes within the white blood cells single cell stream is broken accurately into tiny droplets is desired, the region of the lymphocytes on the FSC–SSC plot by a fine nozzle vibrating at ultrasonic frequency. Very would be outlined and a gate placed on the lymphocyte cell rapid computation of the signals elicited by the cell in the population. How this is then represented is described in the flow chamber makes it possible to deflect droplets car- following example: Jones et al. (2012) explored the expres- rying cells of interest using positive, neutral, or negative sion patterns of T-plastin (PLS3) on Sézary cells. Single-color

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    6 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us