Catalog of GA Control Systems

Catalog of GA Control Systems

GA automation technology product catalog Contact information GEBHARDT Automation GmbH Thüngenfeld 3 D- 58256 Ennepetal Germany Tel.: +49 2333 7908 - 0 available during working hours, Mo to Fr, from 800 to 1700 (5 pm) central european time (CET, GMT+1). FAX: +49 2333 7908 - 24 Web: www.gebhardt-automation.de Support [email protected] Information [email protected] Date: 10/2012 GA catalog_Rev 02.01_2012-10-09 en.doc page 2 of 40 Contents GA BlueLine Systems ............................................................................................................4 Redundancy, fault tolerance and voting...............................................................................................5 Machinery Monitoring Systems............................................................................................................6 Monitoring Capabilities.........................................................................................................................7 GA TMR/10-S.......................................................................................................................................8 GA TMR SMART-S ..............................................................................................................................9 GA DUPLEX/7-S ................................................................................................................................10 GA DUPLEX SMART-S .....................................................................................................................11 GA DualCore-S, BASIC/4 ..................................................................................................................12 GA COMPACT-FS1 ...........................................................................................................................13 Processor cards ...................................................................................................................14 ICU mod. 2 .........................................................................................................................................14 MPU-M1 .............................................................................................................................................15 I/O cards................................................................................................................................16 Non-safety I/O cards ..........................................................................................................................16 DIGI32 model 6............................................................................................................................. 16 DIGIO model 6.............................................................................................................................. 17 MCAD model 6.............................................................................................................................. 18 MCRTD model 6 ........................................................................................................................... 19 MCMIO model 6............................................................................................................................ 20 SIL3 safety I/O cards..........................................................................................................................21 MCDIN-S model 1......................................................................................................................... 21 MCAD-S model 1.......................................................................................................................... 22 MCDOT-S model 1 ....................................................................................................................... 23 MCADA-S model 1........................................................................................................................ 24 MPADA-S...................................................................................................................................... 25 Field I/O components...........................................................................................................26 TFAB-DIGIO-2oo3..............................................................................................................................26 DFAB-1oo2D......................................................................................................................................27 TFAB-DIGIO.......................................................................................................................................28 TFAB-DSPDA.....................................................................................................................................29 GA SR-01-42-24-00 ...........................................................................................................................30 GA SCM1/xA......................................................................................................................................31 FLKM-D50/B/R/SO171.......................................................................................................................32 VIP-3/SC/D50SUB/F ..........................................................................................................................32 GA TFAB PIO.....................................................................................................................................33 GA FAB PIO MPADA-S .....................................................................................................................33 GA FAB SI MCAD-S ..........................................................................................................................34 GA FAB SIPO MCADA-S...................................................................................................................34 System cable, Standard .....................................................................................................................35 System cable, Frequency...................................................................................................................35 GA Software..........................................................................................................................36 GA BlueEdit........................................................................................................................................36 GA DataView......................................................................................................................................36 GA DataLogDLx .................................................................................................................................36 GA DataLogWin .................................................................................................................................36 GA TurWin..........................................................................................................................................36 GA modOPCserver ............................................................................................................................36 Typical TMC applications ....................................................................................................37 GA catalog_Rev 02.01_2012-10-09 en.doc page 3 of 40 GA BlueLine Systems The GA BlueLine safety and automation Redundant systems can be built using a systems combine functional safety up to single rack. Available rack types are: SIL3 with regular process automation. COMPACT-FS1: SIL3 CPU card with Even closed-loop automation functions internal redundancy, SIL3 I/O cards may achieve SIL3 safety integrity. either internally redundant or full card redundancy, regular CPU and/or I/O For most projects only a small part of pro- cards non-redundant, power supply cess automation needs to meet functional usually redundant. safety criteria. Most parts use regular con- DualCore-S: basically like COM- trol without SIL requirements. The Blue- PACT-FS1, but full-sized 19” rack. Line systems allow the combination of DUPLEX-S: every component fully safety-related and non-safety components redundant. Basically two DualCore-S in a single rack. All non-safety components systems combined in a single rack and are certified to be non-interfering with configured to run in dual-redundant safety functions. mode. Available either as full-scale (DUPLEX/7-S) or as compact (DU- All safety-related components, e.g. SIL3 PLEX SMART-S) version. I/O cards or CPU cards, have internal TMR-S: every relevant component hardware fault tolerance HFT = 1. Thus triple redundant, power supplies only even a single card easily meets all re- dual redundant. Available either as quirements for functional safety. By com- full-scale (TMR/10-S) or as compact bining multiple units into higher order (TMR SMART-S) version. modular redundant systems, high func- tional safety becomes compatible with high COMPACT-FS1 or DualCore-S systems process availability. A DUPLEX system – can be configured for distributed redun- dual modular redundant but all components dancy, where up to four single, identical with additional, internal fault tolerance – units are configured for redundant opera- can continue operation even at most hard- tion as DUPLEX, TMR or QMR system. ware failures. The failed component may The necessary signal exchange between be replaced without stopping the DUPLEX units is

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    40 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us