Preface

Introduction 1

Using ROS 2 RUGGEDCOM ROS v4.3 Device Management 3

System Administration 4

Setup and Configuration 5 User Guide Troubleshooting 6

For RS900

07/2016 RC1275-EN-03 RUGGEDCOM ROS User Guide

Copyright © 2016 Siemens Canada Ltd All rights reserved. Dissemination or reproduction of this document, or evaluation and communication of its contents, is not authorized except where expressly permitted. Violations are liable for damages. All rights reserved, particularly for the purposes of patent application or trademark registration. This document contains proprietary information, which is protected by copyright. All rights are reserved. No part of this document may be photocopied, reproduced or translated to another language without the prior written consent of Siemens Canada Ltd.

Disclaimer Of Liability Siemens has verified the contents of this document against the hardware and/or software described. However, deviations between the product and the documentation may exist. Siemens shall not be liable for any errors or omissions contained herein or for consequential damages in connection with the furnishing, performance, or use of this material. The information given in this document is reviewed regularly and any necessary corrections will be included in subsequent editions. We appreciate any suggested improvements. We reserve the right to make technical improvements without notice.

Registered Trademarks RUGGEDCOM™ and ROS™ are trademarks of Siemens Canada Ltd. Other designations in this manual might be trademarks whose use by third parties for their own purposes would infringe the rights of the owner.

Third Party Copyrights Siemens recognizes the following third party copyrights: • Copyright © 2004 GoAhead Software, Inc. All Rights Reserved.

Open Source RUGGEDCOM ROS contains Open Source Software. For license conditions, refer to the associated License Conditions document.

Security Information Siemens provides products and solutions with industrial security functions that support the secure operation of plants, machines, equipment and/or networks. They are important components in a holistic industrial security concept. With this in mind, Siemens' products and solutions undergo continuous development. Siemens recommends strongly that you regularly check for product updates. For the secure operation of Siemens products and solutions, it is necessary to take suitable preventive action (e.g. cell protection concept) and integrate each component into a holistic, state-of-the-art industrial security concept. Third-party products that may be in use should also be considered. For more information about industrial security, visit http://www.siemens.com/industrialsecurity . To stay informed about product updates as they occur, sign up for a product-specific newsletter. For more information, visit http:// support.automation.siemens.com .

Warranty Refer to the License Agreement for the applicable warranty terms and conditions, if any. For warranty details, visit www.siemens.com/ruggedcom or contact a Siemens customer service representative.

ii RUGGEDCOM ROS User Guide

Contacting Siemens Address Telephone E-mail [email protected] Siemens Canada Ltd Toll-free: 1 888 264 0006 Web Industry Sector Tel: +1 905 856 5288 300 Applewood Crescent Fax: +1 905 856 1995 www.siemens.com/ruggedcom Concord, Ontario Canada, L4K 5C7

iii RUGGEDCOM ROS User Guide

iv RUGGEDCOM ROS User Guide Table of Contents

Table of Contents

Preface ...... xiii Conventions ...... xiii Related Documents ...... xiv System Requirements ...... xiv Accessing Documentation ...... xiv Training ...... xv Customer Support ...... xv

Chapter 1 Introduction ...... 1 1.1 Features and Benefits ...... 1 1.2 Security Recommendations and Considerations ...... 3 1.2.1 Security Recommendations ...... 3 1.2.2 Credential Files ...... 5 1.2.2.1 SSL Certificates ...... 6 1.2.2.2 SSH Key Pairs ...... 8 1.3 Supported Networking Standards ...... 9 1.4 Port Numbering Scheme ...... 9 1.5 Available Services by Port ...... 10 1.6 SNMP Management Interface Base (MIB) Support ...... 12 1.6.1 Supported Standard MIBs ...... 12 1.6.2 Supported Proprietary RUGGEDCOM MIBs ...... 13 1.6.3 Supported Agent Capabilities ...... 13 1.7 SNMP Traps ...... 14 1.8 ModBus Management Support ...... 16 1.8.1 ModBus Function Codes ...... 16 1.8.2 ModBus Memory Map ...... 17 1.8.3 ModBus Memory Formats ...... 22 1.8.3.1 Text ...... 23 1.8.3.2 Cmd ...... 23 1.8.3.3 Uint16 ...... 23 1.8.3.4 Uint32 ...... 24 1.8.3.5 PortCmd ...... 24 1.8.3.6 Alarm ...... 25 1.8.3.7 PSStatusCmd ...... 25

v RUGGEDCOM ROS Table of Contents User Guide

1.8.3.8 TruthValues ...... 25 1.9 SSH and SSL Keys and Certificates ...... 26 1.9.1 Certificate and Keys Life Cycle ...... 26 1.9.2 Certificate and Key Requirements ...... 27

Chapter 2 Using ROS ...... 29 2.1 Connecting to ROS ...... 29 2.1.1 Connecting Directly ...... 29 2.1.2 Connecting via the Network ...... 30 2.2 Logging In ...... 31 2.3 Logging Out ...... 32 2.4 Using the Web Interface ...... 33 2.5 Using the Console Interface ...... 34 2.6 Using the Command Line Interface ...... 36 2.6.1 Available CLI Commands ...... 36 2.6.2 Tracing Events ...... 39 2.6.3 Executing Commands Remotely via RSH ...... 40 2.6.4 Using SQL Commands ...... 40 2.6.4.1 Finding the Correct Table ...... 41 2.6.4.2 Retrieving Information ...... 41 2.6.4.3 Changing Values in a Table ...... 43 2.6.4.4 Resetting a Table ...... 44 2.6.4.5 Using RSH and SQL ...... 44 2.7 Selecting Ports in RUGGEDCOM ROS ...... 44 2.8 Managing the Flash File System ...... 45 2.8.1 Viewing a List of Flash Files ...... 45 2.8.2 Viewing Flash File Details ...... 45 2.8.3 Defragmenting the Flash File System ...... 46 2.9 Accessing BIST Mode ...... 46 2.10 Managing SSH Public Keys ...... 47 2.10.1 Adding a Public Key ...... 47 2.10.2 Viewing a List of Public Keys ...... 49 2.10.3 Updating a Public Key ...... 49 2.10.4 Deleting a Public Key ...... 50

Chapter 3 Device Management ...... 51 3.1 Viewing Product Information ...... 51 3.2 Viewing CPU Diagnostics ...... 53 3.3 Restoring Factory Defaults ...... 54

vi RUGGEDCOM ROS User Guide Table of Contents

3.4 Uploading/Downloading Files ...... 55 3.4.1 Uploading/Downloading Files Using XMODEM ...... 56 3.4.2 Uploading/Downloading Files Using a TFTP Client ...... 57 3.4.3 Uploading/Downloading Files Using a TFTP Server ...... 58 3.4.4 Uploading/Downloading Files Using an SFTP Server ...... 58 3.5 Managing Logs ...... 59 3.5.1 Viewing Local Logs ...... 59 3.5.2 Clearing Local Logs ...... 60 3.5.3 Configuring the Local System Log ...... 60 3.5.4 Managing Remote Logging ...... 61 3.5.4.1 Configuring the Remote Syslog Client ...... 61 3.5.4.2 Viewing a List of Remote Syslog Servers ...... 62 3.5.4.3 Adding a Remote Syslog Server ...... 63 3.5.4.4 Deleting a Remote Syslog Server ...... 64 3.6 Managing Ethernet Ports ...... 65 3.6.1 Controller Protection Through Link Fault Indication (LFI) ...... 66 3.6.2 Viewing the Status of Ethernet Ports ...... 67 3.6.3 Viewing Statistics for All Ethernet Ports ...... 68 3.6.4 Viewing Statistics for Specific Ethernet Ports ...... 68 3.6.5 Clearing Statistics for Specific Ethernet Ports ...... 71 3.6.6 Configuring an Ethernet Port ...... 72 3.6.7 Configuring Port Rate Limiting ...... 74 3.6.8 Configuring Port Mirroring ...... 76 3.6.9 Configuring Link Detection ...... 77 3.6.10 Detecting Cable Faults ...... 79 3.6.10.1 Viewing Cable Diagnostics Results ...... 79 3.6.10.2 Performing Cable Diagnostics ...... 81 3.6.10.3 Clearing Cable Diagnostics ...... 83 3.6.10.4 Determining the Estimated Distance To Fault (DTF) ...... 83 3.6.11 Resetting Ethernet Ports ...... 84 3.7 Managing IP Interfaces ...... 84 3.7.1 Viewing a List of IP Interfaces ...... 85 3.7.2 Adding an IP Interface ...... 85 3.7.3 Deleting an IP Interface ...... 87 3.8 Managing IP Gateways ...... 88 3.8.1 Viewing a List of IP Gateways ...... 88 3.8.2 Adding an IP Gateway ...... 89 3.8.3 Deleting an IP Gateway ...... 90 3.9 Configuring IP Services ...... 91 3.10 Managing Remote Monitoring ...... 93

vii RUGGEDCOM ROS Table of Contents User Guide

3.10.1 Managing RMON History Controls ...... 94 3.10.1.1 Viewing a List of RMON History Controls ...... 94 3.10.1.2 Adding an RMON History Control ...... 94 3.10.1.3 Deleting an RMON History Control ...... 96 3.10.2 Managing RMON Alarms ...... 97 3.10.2.1 Viewing a List of RMON Alarms ...... 98 3.10.2.2 Adding an RMON Alarm ...... 99 3.10.2.3 Deleting an RMON Alarm ...... 101 3.10.3 Managing RMON Events ...... 102 3.10.3.1 Viewing a List of RMON Events ...... 103 3.10.3.2 Adding an RMON Event ...... 103 3.10.3.3 Deleting an RMON Event ...... 105 3.11 Upgrading/Downgrading Firmware ...... 105 3.11.1 Upgrading Firmware ...... 106 3.11.2 Downgrading Firmware ...... 106 3.12 Resetting the Device ...... 107 3.13 Decommissioning the Device ...... 108

Chapter 4 System Administration ...... 111 4.1 Configuring the System Information ...... 111 4.2 Customizing the Login Screen ...... 112 4.3 Configuring Passwords ...... 112 4.4 Clearing Private Data ...... 115 4.5 Enabling/Disabling the Web Interface ...... 116 4.6 Managing Alarms ...... 116 4.6.1 Viewing a List of Pre-Configured Alarms ...... 117 4.6.2 Viewing and Clearing Latched Alarms ...... 118 4.6.3 Configuring an Alarm ...... 118 4.6.4 Authentication Related Security Alarms ...... 121 4.6.4.1 Security Alarms for Login Authentication ...... 121 4.6.4.2 Security Messages for Port Authentication ...... 123 4.7 Managing the Configuration File ...... 124 4.7.1 Configuring Data Encryption ...... 124 4.7.2 Updating the Configuration File ...... 126 4.8 Managing an Authentication Server ...... 126 4.8.1 Managing RADIUS Authentication ...... 127 4.8.1.1 Configuring the RADIUS Server ...... 128 4.8.1.2 Configuring the RADIUS Client ...... 128 4.8.2 Managing TACACS+ Authentication ...... 130 4.8.2.1 Configuring TACACS+ ...... 130

viii RUGGEDCOM ROS User Guide Table of Contents

4.8.2.2 Configuring User Privileges ...... 131

Chapter 5 Setup and Configuration ...... 133 5.1 Managing Virtual LANs ...... 133 5.1.1 VLAN Concepts ...... 134 5.1.1.1 Tagged vs. Untagged Frames ...... 134 5.1.1.2 Native VLAN ...... 134 5.1.1.3 The Management VLAN ...... 135 5.1.1.4 Edge and Trunk Port Types ...... 135 5.1.1.5 Ingress and Egress Rules ...... 135 5.1.1.6 Forbidden Ports List ...... 136 5.1.1.7 VLAN-Aware and VLAN-Unaware Modes ...... 136 5.1.1.8 GARP VLAN Registration Protocol (GVRP) ...... 137 5.1.1.9 PVLAN Edge ...... 138 5.1.1.10 QinQ ...... 138 5.1.1.11 VLAN Advantages ...... 140 5.1.2 Viewing a List of VLANs ...... 141 5.1.3 Configuring VLANs Globally ...... 141 5.1.4 Configuring VLANs for Specific Ethernet Ports ...... 143 5.1.5 Managing Static VLANs ...... 145 5.1.5.1 Viewing a List of Static VLANs ...... 145 5.1.5.2 Adding a Static VLAN ...... 145 5.1.5.3 Deleting a Static VLAN ...... 147 5.2 Managing Spanning Tree Protocol ...... 148 5.2.1 RSTP Operation ...... 148 5.2.1.1 RSTP States and Roles ...... 149 5.2.1.2 Edge Ports ...... 151 5.2.1.3 Point-to-Point and Multipoint Links ...... 152 5.2.1.4 Path and Port Costs ...... 152 5.2.1.5 Bridge Diameter ...... 153 5.2.1.6 eRSTP ...... 153 5.2.1.7 Fast Root Failover ...... 154 5.2.2 RSTP Applications ...... 154 5.2.2.1 RSTP in Structured Wiring Configurations ...... 155 5.2.2.2 RSTP in Ring Backbone Configurations ...... 156 5.2.2.3 RSTP Port Redundancy ...... 158 5.2.3 MSTP Operation ...... 158 5.2.3.1 MSTP Regions and Interoperability ...... 159 5.2.3.2 MSTP Bridge and Port Roles ...... 160 5.2.3.3 Benefits of MSTP ...... 161

ix RUGGEDCOM ROS Table of Contents User Guide

5.2.3.4 Implementing MSTP on a Bridged Network ...... 162 5.2.4 Configuring STP Globally ...... 163 5.2.5 Configuring STP for Specific Ethernet Ports ...... 164 5.2.6 Configuring eRSTP ...... 167 5.2.7 Viewing Global Statistics for STP ...... 169 5.2.8 Viewing STP Statistics for Ethernet Ports ...... 171 5.2.9 Managing Multiple Spanning Tree Instances ...... 173 5.2.9.1 Viewing Statistics for Global MSTIs ...... 173 5.2.9.2 Viewing Statistics for Port MSTIs ...... 175 5.2.9.3 Configuring the MST Region Identifier ...... 176 5.2.9.4 Configuring a Global MSTI ...... 177 5.2.9.5 Configuring an MSTI for an Ethernet Port ...... 178 5.2.10 Clearing Spanning Tree Protocol Statistics ...... 180 5.3 Managing Classes of Service ...... 180 5.3.1 Configuring Classes of Service Globally ...... 181 5.3.2 Configuring Classes of Service for Specific Ethernet Ports ...... 182 5.3.3 Configuring Priority to CoS Mapping ...... 184 5.3.4 Configuring DSCP to CoS Mapping ...... 185 5.4 Managing MAC Addresses ...... 186 5.4.1 Viewing a List of MAC Addresses ...... 187 5.4.2 Configuring MAC Address Learning Options ...... 188 5.4.3 Configuring MAC Address Flooding Options ...... 188 5.4.4 Managing Static MAC Addresses ...... 190 5.4.4.1 Viewing a List of Static MAC Addresses ...... 190 5.4.4.2 Adding a Static MAC Address ...... 190 5.4.4.3 Deleting a Static MAC Address ...... 192 5.4.5 Purging All Dynamic MAC Addresses ...... 193 5.5 Managing Time Services ...... 193 5.5.1 Configuring the Time and Date ...... 194 5.5.2 Managing NTP ...... 195 5.5.2.1 Enabling/Disabling NTP Service ...... 195 5.5.2.2 Configuring NTP Servers ...... 196 5.6 Managing SNMP ...... 197 5.6.1 Managing SNMP Users ...... 198 5.6.1.1 Viewing a List of SNMP Users ...... 198 5.6.1.2 Adding an SNMP User ...... 199 5.6.1.3 Deleting an SNMP User ...... 201 5.6.2 Managing Security-to-Group Mapping ...... 203 5.6.2.1 Viewing a List of Security-to-Group Maps ...... 203 5.6.2.2 Adding a Security-to-Group Map ...... 203

x RUGGEDCOM ROS User Guide Table of Contents

5.6.2.3 Deleting a Security-to-Group Map ...... 205 5.6.3 Managing SNMP Groups ...... 205 5.6.3.1 Viewing a List of SNMP Groups ...... 206 5.6.3.2 Adding an SNMP Group ...... 206 5.6.3.3 Deleting an SNMP Group ...... 208 5.7 Managing Network Discovery ...... 209 5.7.1 Network Discovery Concepts ...... 209 5.7.1.1 Link Layer Discovery Protocol (LLDP) ...... 209 5.7.1.2 RUGGEDCOM Discovery Protocol (RCDP) ...... 210 5.7.2 Configuring LLDP Globally ...... 210 5.7.3 Configuring LLDP for an Ethernet Port ...... 212 5.7.4 Enabling/Disabling RCDP ...... 213 5.7.5 Viewing Global Statistics and Advertised System Information ...... 214 5.7.6 Viewing Statistics for LLDP Neighbors ...... 215 5.7.7 Viewing Statistics for LLDP Ports ...... 216 5.8 Managing Multicast Filtering ...... 217 5.8.1 Managing IGMP ...... 217 5.8.1.1 IGMP Concepts ...... 217 5.8.1.2 Viewing a List of Multicast Group Memberships ...... 221 5.8.1.3 Viewing Forwarding Information for Multicast Groups ...... 222 5.8.1.4 Configuring IGMP ...... 223 5.8.2 Managing GMRP ...... 224 5.8.2.1 GMRP Concepts ...... 225 5.8.2.2 Viewing a Summary of Multicast Groups ...... 227 5.8.2.3 Configuring GMRP Globally ...... 227 5.8.2.4 Configuring GMRP for Specific Ethernet Ports ...... 228 5.8.2.5 Viewing a List of Static Multicast Groups ...... 230 5.8.2.6 Adding a Static Multicast Group ...... 230 5.8.2.7 Deleting a Static Multicast Group ...... 231 5.9 Managing Port Security ...... 232 5.9.1 Port Security Concepts ...... 233 5.9.1.1 Static MAC Address-Based Authentication ...... 233 5.9.1.2 IEEE 802.1x Authentication ...... 233 5.9.1.3 IEEE 802.1X Authentication with MAC Address-Based Authentication ...... 234 5.9.1.4 Assigning VLANS with Tunnel Attributes ...... 235 5.9.2 Viewing a List of Authorized MAC Addresses ...... 235 5.9.3 Configuring Port Security ...... 236 5.9.4 Configuring IEEE 802.1X ...... 238 5.10 Managing Link Aggregation ...... 240 5.10.1 Link Aggregation Concepts ...... 241

xi RUGGEDCOM ROS Table of Contents User Guide

5.10.1.1 Rules and Limitations ...... 242 5.10.1.2 Link Aggregation and Layer 2 Features ...... 242 5.10.1.3 Link Aggregation and Physical Layer Features ...... 243 5.10.2 Managing Port Trunks ...... 243 5.10.2.1 Viewing a List of Port Trunks ...... 243 5.10.2.2 Adding a Port Trunk ...... 244 5.10.2.3 Deleting a Port Trunk ...... 245

Chapter 6 Troubleshooting ...... 247 6.1 General ...... 247 6.2 Ethernet Ports ...... 248 6.3 Spanning Tree ...... 248 6.4 VLANs ...... 249

xii RUGGEDCOM ROS User Guide Preface Preface

This guide describes v4.3 of ROS (Rugged Operating System) running on the RUGGEDCOM RS900. It contains instructions and guidelines on how to use the software, as well as some general theory. It is intended for use by network technical support personnel who are familiar with the operation of networks. It is also recommended for use by network and system planners, system programmers, and line technicians.

IMPORTANT! Some of the parameters and options described may not be available depending on variations in the device hardware. While every attempt is made to accurately describe the specific parameters and options available, this Guide should be used as a companion to the Help text included in the software.

Conventions

This User Guide uses the following conventions to present information clearly and effectively.

Alerts The following types of alerts are used when necessary to highlight important information.

DANGER! DANGER alerts describe imminently hazardous situations that, if not avoided, will result in death or serious injury.

WARNING! WARNING alerts describe hazardous situations that, if not avoided, may result in serious injury and/or equipment damage.

CAUTION! CAUTION alerts describe hazardous situations that, if not avoided, may result in equipment damage.

IMPORTANT! IMPORTANT alerts provide important information that should be known before performing a procedure or step, or using a feature.

NOTE NOTE alerts provide additional information, such as facts, tips and details.

CLI Command Syntax The syntax of commands used in a Command Line Interface (CLI) is described according to the following conventions:

Conventions xiii RUGGEDCOM ROS Preface User Guide

Example Description

command Commands are in bold.

command parameter Parameters are in plain text.

command parameter1 parameter2 Parameters are listed in the order they must be entered.

command parameter1 parameter2 Parameters in italics must be replaced with a user-defined value.

command [ parameter1 | parameter2 ] Alternative parameters are separated by a vertical bar (|). Square brackets indicate a required choice between two or more parameters.

command { parameter3 | parameter4 } Curly brackets indicate an optional parameter(s).

command parameter1 parameter2 { parameter3 | All commands and parameters are presented in the order they must parameter4 } be entered.

Related Documents

Other documents that may be of interest include: • RUGGEDCOM RS900 Installation Guide

System Requirements

Each workstation used to connect to the RUGGEDCOM ROS interface must meet the following system requirements: • Must have one of the following Web browsers installed: ▫ Microsoft Internet Explorer 8.0 or higher ▫ Mozilla Firefox ▫ Google Chrome ▫ Iceweasel/IceCat (Linux Only) • Must have a working Ethernet interface compatible with at least one of the port types on the RUGGEDCOM device • The ability to configure an IP address and netmask on the computer’s Ethernet interface

Accessing Documentation

The latest user documentation for RUGGEDCOM ROS v4.3 is available online at www.siemens.com/ruggedcom. To request or inquire about a user document, contact Siemens Customer Support.

xiv Related Documents RUGGEDCOM ROS User Guide Preface

Training

Siemens offers a wide range of educational services ranging from in-house training of standard courses on networking, Ethernet switches and routers, to on-site customized courses tailored to the customer's needs, experience and application. Siemens' Educational Services team thrives on providing our customers with the essential practical skills to make sure users have the right knowledge and expertise to understand the various technologies associated with critical communications network infrastructure technologies. Siemens' unique mix of IT/Telecommunications expertise combined with domain knowledge in the utility, transportation and industrial markets, allows Siemens to provide training specific to the customer's application. For more information about training services and course availability, visit www.siemens.com/ruggedcom or contact a Siemens Sales representative.

Customer Support

Customer support is available 24 hours, 7 days a week for all Siemens customers. For technical support or general information, contact Siemens Customer Support through any of the following methods: Online Visit http://www.siemens.com/automation/support-request to submit a Support Request (SR) or check on the status of an existing SR.

Telephone Call a local hotline center to submit a Support Request (SR). To locate a local hotline center, visit http:// www.automation.siemens.com/mcms/aspa-db/en/automation-technology/Pages/default.aspx .

Mobile App Install the Industry Online Support app by Siemens AG on any Android, Apple iOS or Windows mobile device and be able to: • Access Siemens' extensive library of support documentation, including FAQs and manuals • Submit SRs or check on the status of an existing SR • Contact a local Siemens representative from Sales, Technical Support, Training, etc. • Ask questions or share knowledge with fellow Siemens customers and the support community

Training xv RUGGEDCOM ROS User Guide Preface

Customer Support xvi RUGGEDCOM ROS Chapter 1 User Guide Introduction

Introduction

Welcome to the RUGGEDCOM ROS v4.3 Software User Guide for the RS900. This Guide describes the wide array of carrier grade features made available by ROS (Rugged Operating System).

CONTENTS • Section 1.1, “Features and Benefits” • Section 1.2, “Security Recommendations and Considerations” • Section 1.3, “Supported Networking Standards” • Section 1.4, “Port Numbering Scheme” • Section 1.5, “Available Services by Port” • Section 1.6, “SNMP Management Interface Base (MIB) Support” • Section 1.7, “SNMP Traps” • Section 1.8, “ModBus Management Support” • Section 1.9, “SSH and SSL Keys and Certificates”

Section 1.1 Features and Benefits

The following describes the many features available in RUGGEDCOM ROS and their benefits: • Cyber Security Cyber security is an urgent issue in many industries where advanced automation and communications networks play a crucial role in mission critical applications and where high reliability is of paramount importance. Key RUGGEDCOM ROS features that address security issues at the local area network level include:

Passwords Multi-level user passwords secures against unauthorized configuration

SSH/SSL Extends capability of password protection to add encryption of passwords and data as they cross the network

Enable/Disable Ports Capability to disable ports so that traffic cannot pass

802.1Q VLAN Provides the ability to logically segregate traffic between predefined ports on switches

SNMPv3 Encrypted authentication and access security

HTTPS For secure access to the Web interface

• Enhanced Rapid Spanning Tree Protocol (eRSTP)™ Siemens's eRSTP allows the creation of fault-tolerant ring and mesh Ethernet networks that incorporate redundant links that are pruned to prevent loops. eRSTP implements both STP and RSTP to promote interoperability with commercial switches, unlike other proprietary ring solutions. The fast root failover feature of eRSTP provides quick network convergence in case of an RSTP root bridge failure in a mesh topology.

Features and Benefits 1 Chapter 1 RUGGEDCOM ROS Introduction User Guide

• Quality of Service (IEEE 802.1p) Some networking applications such as real-time control or VoIP (Voice over IP) require predictable arrival times for Ethernet frames. Switches can introduce latency in times of heavy network traffic due to the internal queues that buffer frames and then transmit on a first come first serve basis. RUGGEDCOM ROS supports Class of Service, which allows time critical traffic to jump to the front of the queue, thus minimizing latency and reducing jitter to allow such demanding applications to operate correctly. RUGGEDCOM ROS allows priority classification by port, tags, MAC address, and IP Type of Service (ToS). A configurable weighted fair queuing algorithm controls how frames are emptied from the queues. • VLAN (IEEE 802.1Q) Virtual Local Area Networks (VLAN) allow the segregation of a physical network into separate logical networks with independent broadcast domains. A measure of security is provided since hosts can only access other hosts on the same VLAN and traffic storms are isolated. RUGGEDCOM ROS supports 802.1Q tagged Ethernet frames and VLAN trunks. Port based classification allows legacy devices to be assigned to the correct VLAN. GVRP support is also provided to simplify the configuration of the switches on the VLAN. • Simple Network Management Protocol (SNMP) SNMP provides a standardized method, for network management stations, to interrogate devices from different vendors. SNMP versions supported by RUGGEDCOM ROS are v1, v2c and v3. SNMPv3 in particular provides security features (such as authentication, privacy, and access control) not present in earlier SNMP versions. RUGGEDCOM ROS also supports numerous standard MIBs (Management Information Base) allowing for easy integration with any Network Management System (NMS). A feature of SNMP is the ability to generate traps upon system events. RUGGEDCOM NMS, the Siemens management solution, can record traps from multiple devices providing a powerful network troubleshooting tool. It also provides a graphical visualization of the network and is fully integrated with all Siemens products. • Remote Monitoring and Configuration with RUGGEDCOM NMS RUGGEDCOM NMS (RNMS) is Siemens's Network Management System software for the discovery, monitoring and management of RUGGEDCOM products and other IP enabled devices on a network. This highly configurable, full-featured product records and reports on the availability and performance of network components and services. Device, network and service failures are quickly detected and reported to reduce downtime. RNMS is especially suited for remotely monitoring and configuring RUGGEDCOM routers, switches, serial servers and WiMAX wireless network equipment. For more information, contact a Siemens Sales representative. • NTP (Network Time Protocol) NTP automatically synchronizes the internal clock of all RUGGEDCOM ROS devices on the network. This allows for correlation of time stamped events for troubleshooting. • Port Rate Limiting RUGGEDCOM ROS supports configurable rate limiting per port to limit unicast and multicast traffic. This can be essential to managing precious network bandwidth for service providers. It also provides edge security for Denial of Service (DoS) attacks. • Broadcast Storm Filtering Broadcast storms wreak havoc on a network and can cause attached devices to malfunction. This could be disastrous on a network with mission critical equipment. RUGGEDCOM ROS limits this by filtering broadcast frames with a user-defined threshold. • Port Mirroring RUGGEDCOM ROS can be configured to duplicate all traffic on one port to a designated port. When combined with a network analyzer, this can be a powerful troubleshooting tool. • Port Configuration and Status RUGGEDCOM ROS allows individual ports to be hard configured for speed, duplex, auto-negotiation, flow control and more. This allows proper connection with devices that do not negotiate or have unusual settings. Detailed status of ports with alarm and SNMP trap on link problems aid greatly in system troubleshooting.

2 Features and Benefits RUGGEDCOM ROS Chapter 1 User Guide Introduction

• Port Statistics and RMON (Remote Monitoring) RUGGEDCOM ROS provides continuously updating statistics per port that provide both ingress and egress packet and counters, as well as detailed error figures. Also provided is full support for RMON statistics. RMON allows for very sophisticated data collection, analysis and detection of traffic patterns. • Multicast Filtering RUGGEDCOM ROS supports static multicast groups and the ability to join or leave multicast groups dynamically using IGMP (Internet Group Management Protocol) or GMRP (GARP Multicast Registration Protocol). • Event Logging and Alarms RUGGEDCOM ROS records all significant events to a non-volatile system log allowing forensic troubleshooting. Events include link failure and recovery, unauthorized access, broadcast storm detection, and self-test diagnostics among others. Alarms provide a snapshot of recent events that have yet to be acknowledged by the network administrator. An external hardware relay is de-energized during the presence of critical alarms, allowing an external controller to react if desired. • HTML Web Browser User Interface RUGGEDCOM ROS provides a simple, intuitive user interface for configuration and monitoring via a standard graphical Web browser or via a standard telcom user interface. All system parameters include detailed online help to make setup a breeze. RUGGEDCOM ROS presents a common look and feel and standardized configuration process, allowing easy migration to other managed RUGGEDCOM products. • Brute Force Attack Prevention Protection against Brute Force Attacks (BFAs) is standard in RUGGEDCOM ROS. If an external host fails to log in to the Terminal or Web interfaces after a fixed number of attempts, the service will be blocked for one hour.

Section 1.2 Security Recommendations and Considerations

This section describes important security-related recommendations and suggestions that should be considered before implementing the RS900 on any network.

CONTENTS • Section 1.2.1, “Security Recommendations” • Section 1.2.2, “Credential Files”

Section 1.2.1 Security Recommendations

To prevent unauthorized access to the device, note the following security recommendations:

Authentication • Replace the default passwords for all user accounts and processes (where applicable) before the device is deployed. • Use strong passwords with high randomization (i.e. entropy), without repetition of characters. Avoid weak passwords such as password1, 123456789, abcdefgh, and any dictionary words or proper names in any combination. For more information about creating strong passwords, refer to the password requirements in Section 4.3, “Configuring Passwords” .

Security Recommendations and Considerations 3 Chapter 1 RUGGEDCOM ROS Introduction User Guide

• Make sure passwords are protected and not shared with unauthorized personnel. • Passwords should not be re-used across different user names and systems, or after they expire. • If RADIUS authentication is done remotely, make sure all communications are within the security perimeter or on a secure channel.

Physical/Remote Access • Do not connect the device to the Internet. Deploy the device only within a secure network perimeter. • Restrict physical access to the device to only authorized personnel. A person with malicious intent could extract critical information, such as certificates, keys, etc. (user passwords are protected by hash codes), or reprogram the device. • Control access to the serial console to the same degree as any physical access to the device. Access to the serial console allows for potential access to the RUGGEDCOM ROS boot loader, which includes tools that may be used to gain complete access to the device. • Only enable services that will be used on the device, including physical ports. Unused physical ports could potentially be used to gain access to the network behind the device. • If SNMP is enabled, limit the number of IP addresses that can connect to the device and change the community names. Also configure SNMP to raise a trap upon authentication failures. For more information, refer to Section 5.6, “Managing SNMP” . • Avoid using insecure services such as Telnet and TFTP, or disable them completely if possible. These services are available for historical reasons and are disabled by default. • Limit the number of simultaneous Web Server, Telnet and SSH sessions allowed. • Configure remote system logging to forward all logs to a central location. For more information, refer to Section 3.5, “Managing Logs” . • Configuration files are provided in the CSV (comma separated values) format for ease of use. Make sure configuration files are properly protected when they exist outside of the device. For instance, encrypt the files, store them in a secure place, and do not transfer them via insecure communication channels. • Management of the configuration file, certificates and keys is the responsibility of the device owner. Consider using RSA key sizes of at least 2048 bits in length and certificates signed with SHA256 for increased cryptographic strength. Before returning the device to Siemens for repair, make sure encryption is disabled (to create a cleartext version of the configuration file) and replace the current certificates and keys with temporary throwaway certificates and keys that can be destroyed upon the device's return. • Be aware of any non-secure protocols enabled on the device. While some protocols, such as HTTPS and SSH, are secure, others, such as Telnet and RSH, were not designed for this purpose. Appropriate safeguards against non- secure protocols should be taken to prevent unauthorized access to the device/network. • Configure port security features on access ports to prevent a third-party from launching various attacks that can harm the network or device. For more information, refer to Section 5.9, “Managing Port Security” .

Hardware/Software • Make sure the latest firmware version is installed, including all security-related patches. For the latest information on security patches for Siemens products, visit the Industrial Security website [http:// www.industry.siemens.com/topics/global/en/industrial-security/news-alerts/Pages/alerts.aspx] or the ProductCERT Security Advisories website [http://www.siemens.com/innovation/en/technology-focus/ siemens-cert/cert-security-advisories.htm] . Updates to Siemens Product Security Advisories can be obtained by subscribing to the RSS feed on the Siemens ProductCERT Security Advisories website, or by following @ProductCert on Twitter. • Configure port security features on access ports to prevent a third-party from launching various attacks that can harm the network or device. For more information, refer to Section 5.9, “Managing Port Security” .

4 Security Recommendations RUGGEDCOM ROS Chapter 1 User Guide Introduction

• Enable BPDU Guard on ports where RSTP BPDUs are not expected. • Use the latest Web browser version compatible with RUGGEDCOM ROS to make sure the most secure Transport Layer Security (TLS) versions and ciphers available are employed. Additionally, 1/n-1 record splitting is enabled in the latest web browser versions of Mozilla Firefox, Google Chrome and Internet Explorer, and mitigates against attacks such as SSL/TLS Protocol Initialization Vector Implementation Information Disclosure Vulnerability (BEAST) for Non-Controlled (NC) versions of RUGGEDCOM ROS. • Modbus can be deactivated if not required by the user. If Modbus activation is required, then it is recommended to follow the security recommendations outlined in this User Guide and to configure the environment according to defense-in-depth best practices. • Prevent access to external, untrusted Web pages while accessing the device via a Web browser. This can assist in preventing potential security threats, such as session hijacking. • For optimal security, use SNMPv3 whenever possible. Use strong passwords without repetitive strings ( e.g. abc or abcabc) with this feature. For more information about creating strong passwords, refer to the password requirements in Section 4.3, “Configuring Passwords” . • Unless required for a particular network topology, the IP Forward setting should be set to { Disabled } to prevent the routing of packets.

NOTE For configuration compatibility reasons, the configured setting will not change when upgrading from RUGGEDCOM ROS versions older than v4.2.0 to v4.2.0 and newer. This setting is always enabled and cannot be configured on versions before v4.2.0. For new units with firmware v4.2.0 this setting is configurable and disabled by default.

Policy • Periodically audit the device to make sure it complies with these recommendations and/or any internal security policies. • Review the user documentation for other Siemens products used in coordination with device for further security recommendations.

Section 1.2.2 Credential Files

RUGGEDCOM ROS uses security keys to establish secure remote logins (SSH) and Web access (SSL). It is strongly recommended that a unique SSL certificate and SSH keys be created and provisioned. New RUGGEDCOM ROS-based units from Siemens will be shipped with a unique certificate and keys preconfigured in the ssl.crt and ssh.keys flash files. The default and auto-generated SSL certificates are self-signed. It is recommended to use an SSL certificate that is either signed by a trusted third-party Certificate Authority (CA) or by an organization's own CA. This technique is described in the Siemens application note: Creating/Uploading SSH Keys and SSL Certificates to ROS Using Windows, available from www.siemens.com/ruggedcom. The sequence of events related to Key Management during an upgrade to RUGGEDCOM ROS v4.3 or later is as follows:

NOTE The auto-generation of SSH keys is not available for Non-Controlled (NC) versions of RUGGEDCOM ROS.

• On first boot, RUGGEDCOM ROS will start the SSH and SSL services using the default keys.

Credential Files 5 Chapter 1 RUGGEDCOM ROS Introduction User Guide

• Immediately after boot, RUGGEDCOM ROS will start to generate a unique SSL certificate and SSH key pair, and save each one to its corresponding flash file. This process may take several minutes to complete. As each one is created, the corresponding service is immediately restarted with the new keys. • At any time during the key generation process, custom keys can be uploaded. The custom keys will take precedence over both the default and auto-generated keys. • On subsequent boot, if there is a valid ssl.crt file, the default certificate will not be used for SSL. If there is a valid ssh.keys file, the default SSH key will not be used. • At any time, new keys may be uploaded or generated by RUGGEDCOM ROS using the sslkeygen or sshkeygen CLI commands.

CONTENTS • Section 1.2.2.1, “SSL Certificates” • Section 1.2.2.2, “SSH Key Pairs”

Section 1.2.2.1 SSL Certificates

RUGGEDCOM ROS supports SSL certificates that conform to the following specifications: • X.509 v3 digital certificate format • PEM format • For RUGGEDCOM ROS Controlled verions: RSA key pair, 1024, 2048 or 3072 bits; or EC 256, 384 or 521 bits • For RUGGEDCOM ROS Non-Controlled (NC) verions: RSA key pair, 512 to 2048 bits The RSA key pair used in the default certificate and in those generated by RUGGEDCOM ROS uses a public key of 1024 bits in length.

NOTE RSA keys smaller than 2048 bits in length are not recommended. Support is only included here for compatibility with legacy equipment.

NOTE The default certificate and keys are common to all RUGGEDCOM ROS versions without a certificate or key files. That is why it is important to either allow the key auto-generation to complete or to provision custom keys. In this way, one has at least unique, and at best, traceable and verifiable keys installed when establishing secure communication with the unit.

NOTE RSA key generation times increase depending on the key length. 1024 bit RSA keys may take several minutes to generate, whereas 2048 bit keys may take significantly longer. A typical modern PC system, however, can generate these keys in seconds.

The following (bash) shell script fragment uses the openssl command line utility to generate a self-signed X.509 v3 SSL certificate with a 1024 bit RSA key suitable for use in RUGGEDCOM ROS. Note that two standard PEM files are required: the SSL certificate and the RSA private key file. These are concatenated into the resulting ssl.crt file, which may then be uploaded to RUGGEDCOM ROS:

# RSA key size: BITS=1024 # 20 years validity:

6 SSL Certificates RUGGEDCOM ROS Chapter 1 User Guide Introduction

DAYS=7305

# Values that will be stored in the Distinguished Name fields:

COUNTRY_NAME=CA # Two-letter country code STATE_OR_PROVINCE_NAME=Ontario # State or Province LOCALITY_NAME=Concord # City ORGANIZATION=Ruggedcom.com # Your organization's name ORGANIZATION_CA=${ORGANIZATION}_CA # Your Certificate Authority COMMON_NAME=RC # The DNS or IP address of the ROS unit ORGANIZATIONAL_UNIT=ROS # Organizational unit name

# Variables used in the construction of the certificate REQ_SUBJ="/C=${COUNTRY_NAME}/ST=${STATE_OR_PROVINCE_NAME}/L=${LOCALITY_NAME}/O=${ORGANIZATION}/OU= ${ORGANIZATIONAL_UNIT}/CN=${COMMON_NAME}/" REQ_SUBJ_CA="/C=${COUNTRY_NAME}/ST=${STATE_OR_PROVINCE_NAME}/L=${LOCALITY_NAME}/O=${ORGANIZATION_CA}/ OU=${ORGANIZATIONAL_UNIT}/"

######################################################################## # Make the self-signed SSL certificate and RSA key pair:

openssl req -x509 -newkey rsa:${BITS} -nodes \ -days ${DAYS} -subj ${REQ_SUBJ} \ -keyout ros_ssl.key \ -out ros_ssl.crt

# Concatenate Cert and Key into a single file suitable for upload to ROS: # Note that cert must precede the RSA key: cat ros_ssl.crt ros_ssl.key > ssl.crt

For information on creating SSL certificates for use with RUGGEDCOM ROS in a Microsoft Windows environment, refer to the following Siemens application note: Creating/Uploading SSH Keys and SSL Certificates to ROS Using Windows. The following is an example of a self-signed SSL certificate generated by RUGGEDCOM ROS:

Certificate: Data: Version: 3 (0x2) Serial Number: ca:01:2d:c0:bf:f9:fd:f2 Signature Algorithm: sha1WithRSAEncryption Issuer: C=CA, ST=Ontario, L=Concord, O=RuggedCom.com, OU=RC, CN=ROS Validity Not Before: Dec 6 00:00:00 2012 GMT Not After : Dec 7 00:00:00 2037 GMT Subject: C=CA, ST=Ontario, L=Concord, O=RuggedCom.com, OU=RC, CN=ROS Subject Public Key Info: Public Key Algorithm: rsaEncryption RSA Public Key: (1024 bit) Modulus (1024 bit): 00:83:e8:1f:02:6b:cd:34:1f:01:6d:3e:b6:d3:45: b0:18:0a:17:ae:3d:b0:e9:c6:f2:0c:af:b1:3e:e7: fd:f2:0e:75:8d:6a:49:ce:47:1d:70:e1:6b:1b:e2: fa:5a:1b:10:ea:cc:51:41:aa:4e:85:7c:01:ea:c3: 1e:9e:98:2a:a9:62:48:d5:27:1e:d3:18:cc:27:7e: a0:94:29:db:02:5a:e4:03:51:16:03:3a:be:57:7d: 3b:d1:75:47:84:af:b9:81:43:ab:90:fd:6d:08:d3: e8:5b:80:c5:ca:29:d8:45:58:5f:e4:a3:ed:9f:67: 44:0f:1a:41:c9:d7:62:7f:3f Exponent: 65537 (0x10001) X509v3 extensions: X509v3 Subject Key Identifier: EC:F3:09:E8:78:92:D6:41:5F:79:4D:4B:7A:73:AD:FD:8D:12:77:88 X509v3 Authority Key Identifier: keyid:EC:F3:09:E8:78:92:D6:41:5F:79:4D:4B:7A:73:AD:FD:8D:12:77:88

SSL Certificates 7 Chapter 1 RUGGEDCOM ROS Introduction User Guide

DirName:/C=CA/ST=Ontario/L=Concord/O=RuggedCom.com/OU=RC/CN=ROS serial:CA:01:2D:C0:BF:F9:FD:F2 X509v3 Basic Constraints: CA:TRUE Signature Algorithm: sha1WithRSAEncryption 64:cf:68:6e:9f:19:63:0e:70:49:a6:b2:fd:09:15:6f:96:1d: 4a:7a:52:c3:46:51:06:83:7f:02:8e:42:b2:dd:21:d2:e9:07: 5c:c4:4c:ca:c5:a9:10:49:ba:d4:28:fd:fc:9d:a9:0b:3f:a7: 84:81:37:ca:57:aa:0c:18:3f:c1:b2:45:2a:ed:ad:dd:7f:ad: 00:04:76:1c:f8:d9:c9:5c:67:9e:dd:0e:4f:e5:e3:21:8b:0b: 37:39:8b:01:aa:ca:30:0c:f1:1e:55:7c:9c:1b:43:ae:4f:cd: e4:69:78:25:5a:a5:f8:98:49:33:39:e3:15:79:44:37:52:da: 28:dd

Section 1.2.2.2 SSH Key Pairs

Controlled versions of RUGGEDCOM ROS support SSH public/private key pairs that conform to the following specifications: • PEM format • DSA key pair, 1024, 2048 or 3072 bits in length; or RSA 1024, 2048 or 3072 bits in length The DSA key pair used in the default key pair and in those generated by RUGGEDCOM ROS uses a public key of 1024 bits in length.

NOTE DSA or RSA keys smaller than 2048 bits in length are not recommended, and support is only included here for compatibility with legacy equipment.

NOTE DSA/RSA key generation times increase depending on the key length. 1024 bit RSA keys may take several minutes to generate, whereas 2048 bit keys may take significantly longer. A typical modern PC system, however, can generate these keys in seconds.

The following (bash) shell script fragment uses the ssh-keygen command line utility to generate a 1024 bit DSA key suitable for use in RUGGEDCOM ROS. The resulting ssh.keys file, which may then be uploaded to RUGGEDCOM ROS:

# DSA key size: BITS=1024

# Make an SSH key pair: ssh-keygen -t dsa -b 1024 -N '' -f ssh.keys

The following is an example of an SSH key generated by RUGGEDCOM ROS:

Private-Key: (1024 bit) priv: 00:b2:d3:9d:fa:56:99:a5:7a:ba:1e:91:c5:e1:35: 77:85:e8:c5:28:36 pub: 6f:f3:9e:af:e6:d6:fd:51:51:b9:fa:d5:f9:0a:b7: ef:fc:d7:7c:14:59:52:48:52:a6:55:65:b7:cb:38: 2e:84:76:a3:83:62:d0:83:c5:14:b2:6d:7f:cc:f4: b0:61:0d:12:6d:0f:5a:38:02:67:a4:b7:36:1d:49: 0a:d2:58:e2:ff:4a:0a:54:8e:f2:f4:c3:1c:e0:1f: 9b:1a:ee:16:e0:e9:eb:c8:fe:e8:16:99:e9:61:81: ed:e4:f2:58:fb:3b:cb:c3:f5:9a:fa:ed:cd:39:51:

8 SSH Key Pairs RUGGEDCOM ROS Chapter 1 User Guide Introduction

47:90:5d:6d:1b:27:d5:04:c5:de:57:7e:a7:a3:03: e8:fb:0a:d5:32:89:40:12 P: 00:f4:81:c1:9b:5f:1f:eb:ac:43:2e:db:dd:77:51: 6e:1c:62:8d:4e:95:c6:e7:b9:4c:fb:39:9c:9d:da: 60:4b:0f:1f:c6:61:b0:fc:5f:94:e7:45:c3:2b:68: 9d:11:ba:e1:8a:f9:c8:6a:40:95:b9:93:7c:d0:99: 96:bf:05:2e:aa:f5:4e:f0:63:02:00:c7:c2:52:c7: 1a:70:7c:f7:e5:fe:dd:3d:57:02:86:ae:d4:89:20: ca:4b:46:80:ea:de:a1:30:11:5c:91:e2:40:d4:a3: 82:c5:40:3b:25:8e:d8:b2:85:cc:f5:9f:a9:1d:ea: 0a:ac:77:95:ee:d6:f7:61:e3 Q: 00:d5:db:48:18:bd:ec:69:99:eb:ff:5f:e1:40:af: 20:80:6d:5c:b1:23 G: 01:f9:a1:91:c0:82:12:74:49:8a:d5:13:88:21:3e: 32:ea:f1:74:55:2b:de:61:6c:fd:dd:f5:e1:c5:03: 68:b4:ad:40:48:58:62:6c:79:75:b1:5d:42:e6:a9: 97:86:37:d8:1e:e5:65:09:28:86:2e:6a:d5:3d:62: 50:06:b8:d3:f9:d4:9c:9c:75:84:5b:db:96:46:13: f0:32:f0:c5:cb:83:01:a8:ae:d1:5a:ac:68:fb:49: f9:b6:8b:d9:d6:0d:a7:de:ad:16:2b:23:ff:8e:f9: 3c:41:16:04:66:cf:e8:64:9e:e6:42:9a:d5:97:60: c2:e8:9e:f4:bc:8f:6f:e0

Section 1.3 Supported Networking Standards

The following networking standards are supported by RUGGEDCOM ROS:

Standard 10 Mbps Ports 100 Mbps Ports 1000 Mbps Ports Notes

IEEE 802.3x ü ü ü Full Duplex Operation

IEEE 802.3z ü 1000Base-LX

IEEE 802.3ab ü 1000Base-Tx

IEEE 802.1D ü ü ü MAC Bridges

IEEE 802.1Q ü ü ü VLAN (Virtual LAN)

IEEE 802.1p ü ü ü Priority Levels

Section 1.4 Port Numbering Scheme

For quick identification, each port on a RS900 device is assigned a number. All port numbers are silk-screened on the device.

Supported Networking Standards 9 Chapter 1 RUGGEDCOM ROS Introduction User Guide

9

8

7

5 6

3 4

1 2

Figure 1: RS900 Port Numbering (Typical)

Use these numbers to configure applicable features on select ports.

Section 1.5 Available Services by Port

The following table lists the services available under RUGGEDCOM ROS. This table includes the following information: • Services The service supported by the device. • Port Number The port number associated with the service. • Port Open The port state, whether it is always open and cannot be closed, or open only, but can be configured.

NOTE In certain cases, the service might be disabled, but the port can still be open (e.g. TFTP).

• Port Default The default state of the port (i.e. open or closed). • Access Authorized Denotes whether the ports/services are authenticated during access.

Service Enabled/ Services Port Number Access Authorized Note Disabled

Telnet TCP/23 Disabled Yes Only available through two

10 Available Services by Port RUGGEDCOM ROS Chapter 1 User Guide Introduction

Service Enabled/ Services Port Number Access Authorized Note Disabled management interfaces.

HTTP TCP/80 Enabled — (configurable), redirects to 443

HTTPS TCP/443 Enabled Yes (configurable)

RSH TCP/512 Disabled Yes Only available (configurable) through two management interfaces.

TFTP UDP/69 Disabled No Only available (configurable) through two management interfaces.

SFTP TCP/22 Enabled Yes Only available through two management interfaces.

SNMP UDP/161 Disabled Yes Only available (configurable) through two management interfaces.

SNTP UDP/123 Enabled No Only available (configurable) through two management interfaces.

SSH TCP/22 Enabled Yes Only available through two management interfaces.

ICMP — Enabled No

TACACS+ TCP/49 Disabled Yes (configurable) (configurable)

RADIUS UDP/1812 to send Disabled Yes Only available (configurable), (configurable) through two opens random port management to listen to interfaces.

Remote Syslog UDP/514 Disabled No Only available (configurable) (configurable) through two management interfaces.

TCP Modbus (Server) TCP/502 Disabled No Only available (configurable) through two management interfaces.

TCP Modbus (Switch) TCP/502 Disabled No (configurable)

DHCP, DHCP Agent UDP/67, 68 sending Disabled No msg if enabled - if (configurable) received, always

Available Services by Port 11 Chapter 1 RUGGEDCOM ROS Introduction User Guide

Service Enabled/ Services Port Number Access Authorized Note Disabled come to CPU, dropped if service not configured

RCDP — Disabled Yes (configurable)

Section 1.6 SNMP Management Interface Base (MIB) Support

RUGGEDCOM ROS supports a variety of standard MIBs, proprietary RUGGEDCOM MIBs and Agent Capabilities MIBs, all for SNMP (Simple Network Management Protocol).

CONTENTS • Section 1.6.1, “Supported Standard MIBs” • Section 1.6.2, “Supported Proprietary RUGGEDCOM MIBs” • Section 1.6.3, “Supported Agent Capabilities”

Section 1.6.1 Supported Standard MIBs

RUGGEDCOM ROS supports the following standard MIBs:

Standard MIB Name Title

RFC 2578 SNMPv2-SMI Structure of Management Information Version 2

RFC 2579 SNMPv2-TC Textual Convention s for SMIv2

RFC 2580 SNMPv2-CONF Conformance Statements for SMIv2

IANAifType Enumerated Values of the ifType Object Defined ifTable defined in IF- MIB

RFC 1907 SNMPv2-MIB Management Information Base for SNMPv2

RFC 2011 IP-MIB SNMPv2 Management Information Base for Internet Protocol using SMIv2

RFC 2012 TCP-MIB SNMPv2 Management Information Base for the Transmission Control Protocol using SMIv2

RFC 2013 UDP-MIB Management Information Base for the UDP using SMIv2

RFC 1659 RS-232-MIB Definitions of Managed Objects for RS-232-like Hardware Devices

RFC 2863 IF-MIB The Interface Group MIB

RFC 2819 RMON-MIB Remote Network Monitoring (RMON) management Information base

RFC 4188 BRIDGE-MIB Definitions of Managed Objects for Bridges

12 SNMP Management Interface Base (MIB) Support RUGGEDCOM ROS Chapter 1 User Guide Introduction

Standard MIB Name Title

RFC 4318 RSTP-MIB Definitions of Managed Objects for Bridges with Rapid Spanning Tree Protocol

RFC 3411 SNMP-FRAMEWORK-MIB An Architecture for Describing Simple Network Management Protocol (SNMP) Management Framework

RFC 3414 SNMP-USER-BASED-SM-MIB User-based Security Model (USM) for Version 3 of the Simple Network Management Protocol (SNMPv3)

RFC 3415 SNMP-VIEW-BASED-ACM-MIB View-bsed Access Control Model (VACM) for the Simple Management Protocol (SNMP)

IEEE 802.3ad IEEE8023-LAG-MIB Management Information Base Module for Link Aggregation

IEEE 802.1AB-2005 LLDP-MIB Management Information Base Module for LLDP Configuration, Statistics, Local System Data and Remote Systems Data Components

RFC 4363 Q-BRIDGE-MIB Definitions of Managed Objects for Bridges with Traffic Classes, Multicast Filtering, and Virtual LAN Extensions

Section 1.6.2 Supported Proprietary RUGGEDCOM MIBs

RUGGEDCOM ROS supports the following proprietary RUGGEDCOM MIBs:

File Name MIB Name Description

RUGGEDCOM-MIB.mib RUGGEDCOM-MIB RUGGEDCOM SMI

RUGGEDCOM-TRAPS-MIB.mib RUGGEDCOM-TRAPS-MIB RUGGEDCOM traps definition

RUGGEDCOM-SYS-INFO-MIB.mib RUGGEDCOM-SYS-INFO-MIB General system information about RUGGEDCOM device

RUGGEDCOM-DOT11-MIB.mib RUGGEDCOM-DOT11-MIB Managemet for wireless interface on RUGGEDCOM device

RUGGEDCOM-POE-MIB.mib RUGGEDCOM-POE-MIB Management for PoE ports on RUGGEDCOM device

RUGGEDCOM-SERIAL-MIB.mib RUGGEDCOM-SERIAL-MIB Managemet for seral ports on RUGGEDCOM device

RUGGEDCOM-STP-MIB.mib RUGGEDCOM-STP-MIB Management for RSTP protocol

Section 1.6.3 Supported Agent Capabilities

RUGGEDCOM ROS supports the following agent capabilities for the SNMP agent:

NOTE For information about agent capabilities for SNMPv2, refer to RFC 2580 [http://tools.ietf.org/html/ rfc2580].

Supported Proprietary RUGGEDCOM MIBs 13 Chapter 1 RUGGEDCOM ROS Introduction User Guide

File Name MIB Name Supported MIB

RC-SNMPv2-MIB-AC.mib RC-SNMPv2-MIB-AC SNMPv2-MIB

RC-UDP-MIB-AC.mib RC-UDP-MIB-AC UDP-MIB

RC-TCP-MIB-AC.mib RC-TCP-MIB-AC TCP-MIB

RC-SNMP-USER-BASED-SM-MIB-AC.mib RC-SNMP-USER-BASED-SM-MIB-AC SNMP-USER-BASED-SM-MIB-AC

RC-SNMP-VIEW-BASED-ACM-MIB-AC.mib RC-SNMP-VIEW-BASED-ACM-MIB-AC SNMP-VIEW-BASED-ACM-MIB-AC

RC-IF-MIB-AC.mib RC-IF-MIB-AC IF-MIB

RC-BRIDGE-MIB-AC.mib RC-BRIDGE-MIB-AC BRIDGE-MIB

RC-RMON-MIB-AC.mib RC-RMON-MIB-AC RMON-MIB

RC-Q-BRIDGE-MIB-AC.mib RC-Q-BRIDGE-MIB-AC Q-BRIDGE-MIB

RC-IP-MIB-AC.mib RC-IP-MIB-AC IP-MIB

RC-LLDP-MIB-AC.mib RC-LLDP-MIB-AC LLDP-MIB

RC-LAG-MIB-AC.mib RC-LAG-MIB-AC IEEE8023-LAG-MIB

RC_RSTP-MIB-AC.mib RC_RSTP-MIB-AC RSTP-MIB

RC-RUGGEDCOM-DOT11-MIB-AC.mib RC-RUGGEDCOM-DOT11-MIB-AC RUGGEDCOM-DOT11- MIB

RC-RUGGEDCOM-POE-MIB-AC.mib RC-RUGGEDCOM-POE-MIB-AC RUGGEDCOM-POE-MIB

RC-RUGGEDCOM-STP-AC-MIB.mib RC-RUGGEDCOM-STP-AC-MIB RUGGEDCOM-STP-MIB

RC-RUGGEDCOM-SYS-INFO-MIB-AC.mib RC-RUGGEDCOM-SYS-INFO-MIB-AC RUGGEDCOM-SYS-INFO-MIB

RC-RUGGEDCOM-TRAPS-MIB-AC.mib RC-RUGGEDCOM-TRAPS-MIB-AC RUGGEDCOM-TRAPS-MIB

RUGGEDCOM_RS-232-MIB-AC.mib RUGGEDCOM_RS-232-MIB-AC RS-232-MIB

RC-RUGGEDCOM-SERIAL-MIB-AC.mib RC-RUGGEDCOM-SERIAL-MIB-AC RUGGEDCOM-SERIAL-MIB

Section 1.7 SNMP Traps

The device generates the following standard traps:

Table: Standard Traps

Trap MIB

linkDown IF-MIB

linkUp

authenticationFailure SNMPv2-MIB

coldStart

newRoot BRIDGE-MIB

topologyChage

risingAlarm RMON-MIB

14 SNMP Traps RUGGEDCOM ROS Chapter 1 User Guide Introduction

Trap MIB

fallingAlarm

lldpRemoteTablesChange LLDP-MIB

The device also generates the following proprietary traps:

Table: Proprietary Traps

Trap MIB

genericTrap RUGGEDCOM-TRAPS-MIB

powerSupplyTrap

swUpgradeTrap

cfgChangeTrap

weakPasswordTrap

defaultKeysTrap

Generic traps carry information about events in their severity and description objects. They are sent at the same time an alarm is generated for the device. The following are examples of RUGGEDCOM generic traps:

NOTE Information about generic traps can be retrieved using the CLI command alarms. For more information about the alarms command, refer to Section 2.6.1, “Available CLI Commands” .

Table: Generic Traps

Trap Severity

heap error Alert

NTP server failure notification

real time clock failure Error

failed password Warning

MAC address not learned by switch fabric Warning

BootP client: TFTP transfer failure Error

received looped back BPDU Error

received two consecutive confusing BPDUs on port, forcing down Error

GVRP failed to learn – too many VLANs Warning

The device generates the following traps when specific events occur:

Table: Event-Based Traps

Trap MIB Event

rcRstpNewTopology RUGGEDCOM-STP-MIB This trap is generated when the device topology becomes stable after a topology change occurs on a switch port.

SNMP Traps 15 Chapter 1 RUGGEDCOM ROS Introduction User Guide

Section 1.8 ModBus Management Support

Modbus management support in RUGGEDCOM devices provides a simple interface for retrieving basic status information. ModBus support simplifies the job of SCADA (Supervisory Control and Data Acquisition) system integrators by providing familiar protocols for retrieving RUGGEDCOM device information. ModBus provides mostly read-only status information, but there are some writable registers for operator commands. The ModBus protocol PDU (Protocol Data Unit) format is as follows:

Function Code Data

CONTENTS • Section 1.8.1, “ModBus Function Codes” • Section 1.8.2, “ModBus Memory Map” • Section 1.8.3, “ModBus Memory Formats”

Section 1.8.1 ModBus Function Codes

RUGGEDCOM devices support the following ModBus function codes for device management through ModBus:

NOTE While RUGGEDCOM devices have a variable number of ports, not all registers and bits apply to all products. Registers that are not applicable to a particular device return a zero (0) value. For example, registers referring to serial ports are not applicable to RUGGEDCOM switch devices.

Read Input Registers or Read Holding Registers — 0x04 or 0x03 Example PDU Request

Function Code 1 Byte 0x04(0x03)

Starting Address 2 Bytes 0x0000 to 0xFFFF (Hexadecimal) 128 to 65535 (Decimal)

Number of Input Registers 2 Bytes Bytes 0x0001 to 0x007D

Example PDU Response

Function Code 1 Byte 0x04(0x03)

Byte Count 1 Byte 2 x N a

Number of Input Registers N a x 2 Bytes

a The number of input registers

16 ModBus Management Support RUGGEDCOM ROS Chapter 1 User Guide Introduction

Write Multiple Registers — 0x10 Example PDU Request

Function Code 1 Byte 0x10

Starting Address 2 Bytes 0x0000 to 0xFFFF

Number of Input Registers 2 Bytes Bytes 0x0001 to 0x0079

Byte Count 1 Byte 2 x N b

Registers Value N b x 2 Bytes Value of the register

b The number of input registers

Example PDU Response

Function Code 1 Byte 0x10

Starting Address 2 Bytes 0x0000 to 0xFFFF

Number of Registers 2 Bytes 1 to 121 (0x79)

Section 1.8.2 ModBus Memory Map

The following details how ModBus process variable data is mapped.

Product Info The following data is mapped to the Productinfo table:

Address #Registers Description (Reference Table in UI) R/W Format

0000 16 Product Identification R Text

0010 32 Firmware Identification R Text

0040 1 Number of Ethernet Ports R Uint16

0041 1 Number of Serial Ports R Uint16

0042 1 Number of Alarms R Uint16

0043 1 Power Supply Status R PSStatusCmd

0044 1 FailSafe Relay Status R TruthValue

0045 1 ErrorAlarm Status R TruthValue

Product Write Register The following data is mapped to various tables:

Address #Registers Description (Reference Table in UI) R/W Format

0080 1 Clear Alarms W Cmd

0081 2 Reset Ethernet Ports W PortCmd

ModBus Memory Map 17 Chapter 1 RUGGEDCOM ROS Introduction User Guide

Address #Registers Description (Reference Table in UI) R/W Format

0083 2 Clear Ethernet Statistics W PortCmd

0085 2 Reset Serial Ports W PortCmd

0087 2 Clear Serial Port Statistics W PortCmd

Alarms The following data is mapped to the alarms table:

Address #Registers Description (Reference Table in UI) R/W Format

0100 64 Alarm 1 R Alarm

0140 64 Alarm 2 R Alarm

0180 64 Alarm 3 R Alarm

01C0 64 Alarm 4 R Alarm

0200 64 Alarm 5 R Alarm

0240 64 Alarm 6 R Alarm

0280 64 Alarm 7 R Alarm

02C0 64 Alarm 8 R Alarm

Ethernet Port Status The following data is mapped to the ethPortStats table:

Address #Registers Description (Reference Table in UI) R/W Format

03FE 2 Port Link Status R PortCmd

Ethernet Statistics The following data is mapped to the rmonStats table:

Address #Registers Description (Reference Table in UI) R/W Format

0400 2 Port s1/p1 Statistics - Ethernet In Packets R Uinst32

0402 2 Port s1/p2 Statistics - Ethernet In Packets R Uinst32

0404 2 Port s1/p3 Statistics - Ethernet In Packets R Uinst32

0406 2 Port s1/p4 Statistics - Ethernet In Packets R Uinst32

0408 2 Port s2/p1 Statistics - Ethernet In Packets R Uinst32

040A 2 Port s2/p2 Statistics - Ethernet In Packets R Uinst32

040C 2 Port s2/p3 Statistics - Ethernet In Packets R Uinst32

040E 2 Port s2/p4 Statistics - Ethernet In Packets R Uinst32

0410 2 Port s3/p1 Statistics - Ethernet In Packets R Uinst32

18 ModBus Memory Map RUGGEDCOM ROS Chapter 1 User Guide Introduction

Address #Registers Description (Reference Table in UI) R/W Format

0412 2 Port s3/p2 Statistics - Ethernet In Packets R Uinst32

0414 2 Port s3/p3 Statistics - Ethernet In Packets R Uinst32

0416 2 Port s3/p4 Statistics - Ethernet In Packets R Uinst32

0418 2 Port s4/p1 Statistics - Ethernet In Packets R Uinst32

041A 2 Port s4/p2 Statistics - Ethernet In Packets R Uinst32

041C 2 Port s4/p3 Statistics - Ethernet In Packets R Uinst32

041E 2 Port s4/p4 Statistics - Ethernet In Packets R Uinst32

0420 2 Port s5/p1 Statistics - Ethernet In Packets R Uinst32

0422 2 Port s5/p2 Statistics - Ethernet In Packets R Uinst32

0424 2 Port s5/p3 Statistics - Ethernet In Packets R Uinst32

0426 2 Port s5/p4 Statistics - Ethernet In Packets R Uinst32

0428 2 Port s6/p1 Statistics - Ethernet In Packets R Uinst32

042A 2 Port s6/p2 Statistics - Ethernet In Packets R Uinst32

042C 2 Port s6/p3 Statistics - Ethernet In Packets R Uinst32

042E 2 Port s6/p4 Statistics - Ethernet In Packets R Uinst32

0430 2 Port s7/p1 Statistics - Ethernet In Packets R Uinst32

0432 2 Port s7/p2 Statistics - Ethernet In Packets R Uinst32

0434 2 Port s8/p1 Statistics - Ethernet In Packets R Uinst32

0436 2 Port s8/p2 Statistics - Ethernet In Packets R Uinst32

0440 2 Port s1/p1 Statistics - Ethernet Out Packets R Uinst32

0442 2 Port s1/p2 Statistics - Ethernet Out Packets R Uinst32

0444 2 Port s1/p3 Statistics - Ethernet Out Packets R Uinst32

0446 2 Port s1/p4 Statistics - Ethernet Out Packets R Uinst32

0448 2 Port s2/p1 Statistics - Ethernet Out Packets R Uinst32

044A 2 Port s2/p2 Statistics - Ethernet Out Packets R Uinst32

044C 2 Port s2/p3 Statistics - Ethernet Out Packets R Uinst32

044E 2 Port s2/p4 Statistics - Ethernet Out Packets R Uinst32

0450 2 Port s3/p1 Statistics - Ethernet Out Packets R Uinst32

0452 2 Port s3/p2 Statistics - Ethernet Out Packets R Uinst32

0454 2 Port s3/p3 Statistics - Ethernet Out Packets R Uinst32

0456 2 Port s3/p4 Statistics - Ethernet Out Packets R Uinst32

0458 2 Port s4/p1 Statistics - Ethernet Out Packets R Uinst32

045A 2 Port s4/p2 Statistics - Ethernet Out Packets R Uinst32

045C 2 Port s4/p3 Statistics - Ethernet Out Packets R Uinst32

ModBus Memory Map 19 Chapter 1 RUGGEDCOM ROS Introduction User Guide

Address #Registers Description (Reference Table in UI) R/W Format

045E 2 Port s4/p4 Statistics - Ethernet Out Packets R Uinst32

0460 2 Port s5/p1 Statistics - Ethernet Out Packets R Uinst32

0462 2 Port s5/p2 Statistics - Ethernet Out Packets R Uinst32

0464 2 Port s5/p3 Statistics - Ethernet Out Packets R Uinst32

0466 2 Port s5/p4 Statistics - Ethernet Out Packets R Uinst32

0468 2 Port s6/p1 Statistics - Ethernet Out Packets R Uinst32

046A 2 Port s6/p2 Statistics - Ethernet Out Packets R Uinst32

046C 2 Port s6/p3 Statistics - Ethernet Out Packets R Uinst32

046E 2 Port s6/p4 Statistics - Ethernet Out Packets R Uinst32

0470 2 Port s7/p1 Statistics - Ethernet Out Packets R Uinst32

0472 2 Port s7/p2 Statistics - Ethernet Out Packets R Uinst32

0474 2 Port s8/p1 Statistics - Ethernet Out Packets R Uinst32

0476 2 Port s8/p2 Statistics - Ethernet Out Packets R Uinst32

0480 2 Port s1/p1 Statistics - Ethernet In Packets R Uinst32

0482 2 Port s1/p2 Statistics - Ethernet In Packets R Uinst32

0484 2 Port s1/p3 Statistics - Ethernet In Packets R Uinst32

0486 2 Port s1/p4 Statistics - Ethernet In Packets R Uinst32

0488 2 Port s2/p1 Statistics - Ethernet In Packets R Uinst32

048A 2 Port s2/p2 Statistics - Ethernet In Packets R Uinst32

048C 2 Port s2/p3 Statistics - Ethernet In Packets R Uinst32

048E 2 Port s2/p4 Statistics - Ethernet In Packets R Uinst32

0490 2 Port s3/p1 Statistics - Ethernet In Packets R Uinst32

0492 2 Port s3/p2 Statistics - Ethernet In Packets R Uinst32

0494 2 Port s3/p3 Statistics - Ethernet In Packets R Uinst32

0496 2 Port s3/p4 Statistics - Ethernet In Packets R Uinst32

0498 2 Port s4/p1 Statistics - Ethernet In Packets R Uinst32

049A 2 Port s4/p2 Statistics - Ethernet In Packets R Uinst32

049C 2 Port s4/p3 Statistics - Ethernet In Packets R Uinst32

049E 2 Port s4/p4 Statistics - Ethernet In Packets R Uinst32

04A0 2 Port s5/p1 Statistics - Ethernet In Packets R Uinst32

04A2 2 Port s5/p2 Statistics - Ethernet In Packets R Uinst32

04A4 2 Port s5/p3 Statistics - Ethernet In Packets R Uinst32

04A6 2 Port s5/p4 Statistics - Ethernet In Packets R Uinst32

04A8 2 Port s6/p1 Statistics - Ethernet In Packets R Uinst32

20 ModBus Memory Map RUGGEDCOM ROS Chapter 1 User Guide Introduction

Address #Registers Description (Reference Table in UI) R/W Format

04AA 2 Port s6/p2 Statistics - Ethernet In Packets R Uinst32

04AC 2 Port s6/p3 Statistics - Ethernet In Packets R Uinst32

04AE 2 Port s6/p4 Statistics - Ethernet In Packets R Uinst32

04B0 2 Port s7/p1 Statistics - Ethernet In Packets R Uinst32

04B2 2 Port s7/p2 Statistics - Ethernet In Packets R Uinst32

04B4 2 Port s8/p1 Statistics - Ethernet In Packets R Uinst32

04B6 2 Port s8/p2 Statistics - Ethernet In Packets R Uinst32

04C0 2 Port s1/p1 Statistics - Ethernet Out Packets R Uinst32

04C2 2 Port s1/p2 Statistics - Ethernet Out Packets R Uinst32

04C4 2 Port s1/p3 Statistics - Ethernet Out Packets R Uinst32

04C6 2 Port s1/p4 Statistics - Ethernet Out Packets R Uinst32

04C8 2 Port s2/p1 Statistics - Ethernet Out Packets R Uinst32

04CA 2 Port s2/p2 Statistics - Ethernet Out Packets R Uinst32

04CC 2 Port s2/p3 Statistics - Ethernet Out Packets R Uinst32

04CE 2 Port s2/p4 Statistics - Ethernet Out Packets R Uinst32

04D0 2 Port s3/p1 Statistics - Ethernet Out Packets R Uinst32

04D2 2 Port s3/p2 Statistics - Ethernet Out Packets R Uinst32

04D4 2 Port s3/p3 Statistics - Ethernet Out Packets R Uinst32

04D6 2 Port s3/p4 Statistics - Ethernet Out Packets R Uinst32

04D8 2 Port s4/p1 Statistics - Ethernet Out Packets R Uinst32

04DA 2 Port s4/p2 Statistics - Ethernet Out Packets R Uinst32

04DC 2 Port s4/p3 Statistics - Ethernet Out Packets R Uinst32

04DE 2 Port s4/p4 Statistics - Ethernet Out Packets R Uinst32

04E0 2 Port s5/p1 Statistics - Ethernet Out Packets R Uinst32

04E2 2 Port s5/p2 Statistics - Ethernet Out Packets R Uinst32

04E4 2 Port s5/p3 Statistics - Ethernet Out Packets R Uinst32

04E6 2 Port s5/p4 Statistics - Ethernet Out Packets R Uinst32

04E8 2 Port s6/p1 Statistics - Ethernet Out Packets R Uinst32

04EA 2 Port s6/p2 Statistics - Ethernet Out Packets R Uinst32

04EC 2 Port s6/p3 Statistics - Ethernet Out Packets R Uinst32

04EE 2 Port s6/p4 Statistics - Ethernet Out Packets R Uinst32

04F0 2 Port s7/p1 Statistics - Ethernet Out Packets R Uinst32

04F2 2 Port s7/p2 Statistics - Ethernet Out Packets R Uinst32

04F4 2 Port s8/p1 Statistics - Ethernet Out Packets R Uinst32

ModBus Memory Map 21 Chapter 1 RUGGEDCOM ROS Introduction User Guide

Address #Registers Description (Reference Table in UI) R/W Format

04F6 2 Port s8/p2 Statistics - Ethernet Out Packets R Uinst32

Serial Statistics The following data is mapped to the uartPortStatus table:

Address #Registers Description (Reference Table in UI) R/W Format

0600 2 Port 1 Statistics – Serial In characters R Uint32

0602 2 Port 2 Statistics – Serial In characters R Uint32

0604 2 Port 3 Statistics – Serial In characters R Uint32

0606 2 Port 4 Statistics – Serial In characters R Uint32

0640 2 Port 1 Statistics – Serial Out characters R Uint32

0642 2 Port 2 Statistics – Serial Out characters R Uint32

0644 2 Port 3 Statistics – Serial Out characters R Uint32

0646 2 Port 4 Statistics – Serial Out characters R Uint32

0680 2 Port 1 Statistics – Serial In Packets R Uint32

0682 2 Port 2 Statistics – Serial In Packets R Uint32

0684 2 Port 3 Statistics – Serial In Packets R Uint32

0686 2 Port 4 Statistics – Serial In Packets R Uint32

06C0 2 Port 1 Statistics – Serial Out Packets R Uint32

06C2 2 Port 2 Statistics – Serial Out Packets R Uint32

06C4 2 Port 3 Statistics – Serial Out Packets R Uint32

06C6 2 Port 4 Statistics – Serial Out Packets R Uint32

Section 1.8.3 ModBus Memory Formats

The following ModBus memory formats are supported by Siemens.

CONTENTS • Section 1.8.3.1, “Text” • Section 1.8.3.2, “Cmd” • Section 1.8.3.3, “Uint16” • Section 1.8.3.4, “Uint32” • Section 1.8.3.5, “PortCmd” • Section 1.8.3.6, “Alarm” • Section 1.8.3.7, “PSStatusCmd”

22 ModBus Memory Formats RUGGEDCOM ROS Chapter 1 User Guide Introduction

• Section 1.8.3.8, “TruthValues”

Section 1.8.3.1 Text

The Text format provides a simple ASCII representation of the information related to the product. The most significant register byte of an ASCII characters comes first. For example, consider a Read Multiple Registers request to read Product Identification from location 0x0000.

0x04 0x00 0x00 0x00 0x08

The response may look like:

0x04 0x10 0x53 0x59 0x53 0x54 0x45 0x4D 0x20 0x4E 0x41 0x4D 0x45

0x00 0x00 0x00 0x00 0x00

In this example, starting from byte 3 until the end, the response presents an ASCII representation of the characters for the product identification, which reads as SYSTEM NAME. Since the length of this field is smaller than eight registers, the rest of the field is filled with zeros (0).

Section 1.8.3.2 Cmd

The Cmd format instructs the device to set the output to either true or false. The most significant byte comes first. • FF 00 hex requests output to be True • 00 00 hex requests output to be False • Any value other than the suggested values does not affect the requested operation For example, consider a Write Multiple Registers request to clear alarms in the device.

0x10 0x00 0x80 0x00 0x01 2 0xFF 0x00

• FF 00 for register 00 80 clears the system alarms • 00 00 does not clear any alarms The response may look like:

0x10 0x00 0x80 0x00 0x01

Section 1.8.3.3 Uint16

The Uint16 format describes a Standard ModBus 16 bit register.

Text 23 Chapter 1 RUGGEDCOM ROS Introduction User Guide

Section 1.8.3.4 Uint32

The Uint32 format describes Standard 2 ModBus 16 bit registers. The first register holds the most significant 16 bits of a 32 bit value. The second register holds the least significant 16 bits of a 32 bit value.

Section 1.8.3.5 PortCmd

The PortCmd format describes a bit layout per port, where 1 indicates the requested action is true, and 0 indicates the requested action is false. PortCmd provides a bit layout of a maximum of 32 ports. Therefore, it uses two ModBus regsiters: • The first ModBus register corresponds to ports 1 – 16 • The second ModBus register corresponds to ports 17 – 32 for a particular action Bits that do not apply to a particular product are always set to zero (0). A bit value of 1 indicates that the requested action is true. For example, the port is up. A bit value of 0 indicates that the requested action is false. For example, the port is down.

Reading Data Using PortCmd To understand how to read data using PortCmd, consider a ModBus Request to read multiple registers from locatoin 0x03FE.

0x04 0x03 0xFE 0x00 0x02

The response depends on how many parts are available on the device. For example, if the maximum number of ports on a connected RUGGEDCOM device is 20, the response would be similar to the following:

0x04 0x04 0xF2 0x76 0x00 0x05

In this example, bytes 3 and 4 refer to register 1 at location 0x03FE, and represent the status of ports 1 – 16. Bytes 5 and 6 refer to register 2 at location 0x03FF, and represent the status of ports 17 – 32. The device only has 20 ports, so byte 6 contains the status for ports 17 – 20 starting from right to left. The rest of the bites in register 2 corresponding to the non-existing ports 21 – 31 are zero (0).

Performing Write Actions Using PortCmd To understand how data is written using PortCmd, consider a Write Multiple Register request to clear Ethernet port statistics:

0x10 0x00 0x83 0x00 0x01 2 0x55 0x76 0x00 0x50

A bit value of 1 clears Ethernet statistics on the corresponding port. A bit value of 0 does not clear the Ethernet statistics.

0x10 0x00 0x81 0x00 0x02

24 Uint32 RUGGEDCOM ROS Chapter 1 User Guide Introduction

Section 1.8.3.6 Alarm

The Alarm format is another form of text description. Alarm text corresponds to the alarm description from the table holding all of the alarms. Similar to the Text format, this format returns an ASCII representation of alarms.

NOTE Alarms are stacked in the device in the sequence of their occurence (i.e. Alarm 1, Alarm 2, Alarm 3, etc.).

The first eight alarms from the stack can be returned, if they exist. A zero (0) value is returned if an alarm does not exist.

Section 1.8.3.7 PSStatusCmd

The PSStatusCmd format describes a bit layout for providing the status of available power supplies. Bits 0-4 of the lower byte of the register are used for this purpose. • Bits 0-1: Power Supply 1 Status • Bits 2-3: Power Supply 2 Status Other bits in the register do not provide any system status information.

Bit Value Description

01 Power Supply not present (01 = 1)

10 Power Supply is functional (10 = 2)

11 Power Supply is not functional (11 = 3)

The values used for power supply status are derived from the RUGGEDCOM-specific SNMP MIB.

Reading the Power Supply Status from a Device Using PSStatusCmd To understand how to read the power supply status from a device using PSStatusCmd, consider a ModBus Request to read multiple registers from location 0x0043.

0x04 0x00 0x43 0x00 0x01

The response may look like:

0x04 0x02 0x00 0x0A

The lower byte of the register displays the power supply's status. In this example, both power supplies in the unit are functional.

Section 1.8.3.8 TruthValues

The Truthvalues format represents a true or false status in the device: • 1 indicates the corresponding status for the device to be true

Alarm 25 Chapter 1 RUGGEDCOM ROS Introduction User Guide

• 2 indicates the corresponding status for the device to be false

Reading the FailSafe Relay Status From a Device Using TruthValue To understand how to use the TruthValue format to read the FailSafe Relay status from a device, consider a ModBus request to read multiple registers from location 0x0044.

0x04 0x00 0x44 0x00 0x01

The response may look like:

0x04 0x02 0x00 0x01

The register's lower byte shows the FailSafe Relay status. In this example, the FailSafe Relay is energized.

Reading the ErrorAlarm Status From a Device Using TruthValue To understand how to use the TruthValue format to read the ErrorAlarm status from a device, conside a ModBus request to read mulitple registers from location 0x0045.

0x04 0x00 0x45 0x00 0x01

The response may look like:

0x04 0x02 0x00 0x01

The register's lower byte shows the ErrorAlarm status. In this example, there is no active ERROR, ALERT or CRITICAL alarm in the device.

Section 1.9 SSH and SSL Keys and Certificates

The following describes the SSH and SSL keys and certificates in RS900, along with the certificate and SSH key requirements.

CONTENTS • Section 1.9.1, “Certificate and Keys Life Cycle” • Section 1.9.2, “Certificate and Key Requirements”

Section 1.9.1 Certificate and Keys Life Cycle

Each RUGGEDCOM ROS device is shipped with an SSL certificate and RSA key pair, and a DSA host key pair for SSH, that are generated at and provisioned by the factory. The administrator may upload a new certificate and keys to the system at any time, which will overwrite the existing ones. In addition, CLI commands are available to regenerate SSL certificate and key pair as well as the SSH host key pair. There are three types of certificates and keys used in RUGGEDCOM ROS:

26 SSH and SSL Keys and Certificates RUGGEDCOM ROS Chapter 1 User Guide Introduction

NOTE SSH is not supported in Non-Controlled (NC) versions of RUGGEDCOM ROS.

NOTE Network exposure to a ROS unit operating with the default keys, although always only temporary by design, should be avoided. The best way to reduce or eliminate this exposure is to provision user- created certificate and keys as quickly as possible, and preferably before the unit is placed in network service.

• Default A default certificate and SSL/SSH keys are built in to RUGGEDCOM ROS and are common across all RUGGEDCOM ROS units sharing the same firmware image. In the event that valid SSL certificate or SSL/SSH key files are not available on the device (as is usually only the case when upgrading from an old ROS version that does not support user-configurable keys and therefore does was not shipped with unique, factory-generated keys), the default certificate and keys are put into service *temporarily* so that SSH and SSL (https) sessions can be served until generated or provisioned keys are available. • Auto-Generated If a default SSL certificate and SSL/SSH keys are in use, RUGGEDCOM ROS immediately begins to generate a unique certificate and SSL/SSH keys for the device in the background. This process may take several minutes to complete depending on the requested key length and how busy the device is at the time. If a custom certificate and keys are loaded while auto-generated certificates and keys are being generated, the generator will abort and the custom certificate and keys and will be used. • User-Generated (Recommended) Custom certificates and keys are the most secure option. They give the user complete control over certificate and key management, allow for the provision of certificates signed by a public or local certificate authority, enable strictly controlled access to private keys, and allow authoritative distribution of SSL certificates, any CA certificates, and public SSH keys.

NOTE The RSA key pair corresponding to the SSL certificate must be appended to the certificate in the ssl.crt file.

Section 1.9.2 Certificate and Key Requirements

For SSL, controlled versions of RUGGEDCOM ROS require an X.509 certificate in standard PEM format and an RSA or ECC key pair. The certificate may be self-signed or signed by a separate authority. The RSA key must be 1024, 2048 or 3072 bits in length; the ECC key must be 192, 224, 256, 384 or 521 bits in length. Non-Controlled (NC) versions of RUGGEDCOM ROS require an X.509 certificate in standard PEM format and an RSA key pair. The RSA key must be between 512 and 2048 bits in length. The certificate and keys must be combined in a single ssl.crt file and uploaded to the device. The following is an example of a combined SSL certificate and key:

-----BEGIN CERTIFICATE----- MIIC9jCCAl+gAwIBAgIJAJh6rrehMt3iMA0GCSqGSIb3DQEBBQUAMIGuMQswCQYD VQQGEwJDQTEQMA4GA1UECBMHT250YXJpbzEQMA4GA1UEBxMHQ29uY29yZDESMBAG A1UEChMJUnVnZ2VkY29tMRkwFwYDVQQLExBDdXN0b21lciBTdXBwb3J0MSYwJAYD VQQDEx1XUy1NSUxBTkdPVkFOLlJVR0dFRENPTS5MT0NBTDEkMCIGCSqGSIb3DQEJ ARYVc3VwcG9ydEBydWdnZWRjb20uY29tMB4XDTEyMTAyMzIxMTA1M1oXDTE3MTAy

Certificate and Key Requirements 27 Chapter 1 RUGGEDCOM ROS Introduction User Guide

MjIxMTA1M1owgZwxCzAJBgNVBAYTAlVTMRAwDgYDVQQIEwdPbnRhcmlvMRAwDgYD VQQHEwdDb25jb3JkMRIwEAYDVQQKEwlSdWdnZWRDb20xGTAXBgNVBAsTEEN1c3Rv bWVyIFN1cHBvcnQxFDASBgNVBAMTCzE5Mi4xNjguMS4yMSQwIgYJKoZIhvcNAQkB FhVTdXBwb3J0QHJ1Z2dlZGNvbS5jb20wgZ8wDQYJKoZIhvcNAQEBBQADgY0AMIGJ AoGBALfE4eh2aY+CE3W5a4Wz1Z1RGRP02COHt153wFFrU8/fFQXNhKlQirlAHbNT RSwcTR8ZFapivwYDivn0ogOGFXknYP90gv2oIaSVY08FqZkJW77g3kzkv/8Zrw3m W/cBsZJ8SyKLIDfy401HkHpDOle5NsQFSrziGUPjAOIvvx4rAgMBAAGjLDAqMAkG A1UdEwQCMAAwHQYDVR0OBBYEFER0utgQOifnrflnDtsqNcnvRB0XMA0GCSqGSIb3 DQEBBQUAA4GBAHtBsNZuh8tB3kdqR7Pn+XidCsD70YnI7w0tiy9yiRRhARmVXH8h 5Q1rOeHceri3JFFIOxIxQt4KgCUYJLu+c9Esk/nXQQar3zR7IQCt0qOABPkviiY8 c3ibVbhJjLpR2vNW4xRAJ+HkNNtBOg1xUlp4vOmJ2syYZR+7XAy/OP/S -----END CERTIFICATE------BEGIN RSA PRIVATE KEY----- MIICXAIBAAKBgQC3xOHodmmPghN1uWuFs9WdURkT9Ngjh7ded8BRa1PP3xUFzYSp UIq5QB2zU0UsHE0fGRWqYr8GA4r59KIDhhV5J2D/dIL9qCGklWNPBamZCVu+4N5M 5L//Ga8N5lv3AbGSfEsiiyA38uNNR5B6QzpXuTbEBUq84hlD4wDiL78eKwIDAQAB AoGBAI2CXHuHg23wuk9zAusoOhw0MN1/M1jYz0k9aajIvvdZT3Tyd29yCADy8GwA eUmoWXLS/C4CcBqPa9til8ei3rDn/w8dveVHsi9FXjtVSYqN+ilKw+moMAjZy4kN /kpdpHMohwv/909VWR1AZbr+YTxaG/++tKl5bqXnZl4wHF8xAkEA5vwut8USRg2/ TndOt1e8ILEQNHvHQdQr2et/xNH4ZEo7mqot6skkCD1xmxA6XG64hR3BfxFSZcew Wr4SOFGCtQJBAMurr5FYPJRFGzPM3HwcpAaaMIUtPwNyTtTjywlYcUI7iZVVfbdx 4B7qOadPybTg7wqUrGVkPSzzQelz9YCSSV8CQFqpIsEYhbqfTLZEl83YjsuaE801 xBivaWLIT0b2TvM2O7zSDOG5fv4I990v+mgrQRtmeXshVmEChtKnBcm7HH0CQE6B 2WUfLArDMJ8hAoRczeU1nipXrIh5kWWCgQsTKmUrafdEQvdpT8ja5GpX2Rp98eaU NHfI0cP36JpCdome2eUCQDZN9OrTgPfeDIXzyOiUUwFlzS1idkUGL9nH86iuPnd7 WVF3rV9Dse30sVEk63Yky8uKUy7yPUNWldG4U5vRKmY= -----END RSA PRIVATE KEY-----

For SSH, RUGGEDCOM ROS requires a DSA or RSA host key pair in PEM format. The key must be 1024, 2048 or 3072 bits in length for Controlled versions. The key file is uploaded to the ssh.keys flash file on the device. The following is an example of a PEM formatted SSH key:

-----BEGIN DSA PRIVATE KEY----- MIIBuwIBAAKBgQD0gcGbXx/rrEMu2913UW4cYo1OlcbnuUz7OZyd2mBLDx/GYbD8 X5TnRcMraJ0RuuGK+chqQJW5k3zQmZa/BS6q9U7wYwIAx8JSxxpwfPfl/t09VwKG rtSJIMpLRoDq3qEwEVyR4kDUo4LFQDsljtiyhcz1n6kd6gqsd5Xu1vdh4wIVANXb SBi97GmZ6/9f4UCvIIBtXLEjAoGAAfmhkcCCEnRJitUTiCE+MurxdFUr3mFs/d31 4cUDaLStQEhYYmx5dbFdQuapl4Y32B7lZQkohi5q1T1iUAa40/nUnJx1hFvblkYT 8DLwxcuDAaiu0VqsaPtJ+baL2dYNp96tFisj/475PEEWBGbP6GSe5kKa1Zdgwuie 9LyPb+ACgYBv856v5tb9UVG5+tX5Crfv/Nd8FFlSSFKmVWW3yzguhHajg2LQg8UU sm1/zPSwYQ0SbQ9aOAJnpLc2HUkK0lji/0oKVI7y9MMc4B+bGu4W4OnryP7oFpnp YYHt5PJY+zvLw/Wa+u3NOVFHkF1tGyfVBMXeV36nowPo+wrVMolAEgIVALLTnfpW maV6uh6RxeE1d4XoxSg2 -----END DSA PRIVATE KEY-----

For more information about encryption key management, refer to Section 1.2, “Security Recommendations and Considerations” .

28 Certificate and Key Requirements RUGGEDCOM ROS Chapter 2 User Guide Using ROS

Using ROS

This chapter describes how to use the RUGGEDCOM ROS interface.

CONTENTS • Section 2.1, “Connecting to ROS” • Section 2.2, “Logging In” • Section 2.3, “Logging Out” • Section 2.4, “Using the Web Interface” • Section 2.5, “Using the Console Interface” • Section 2.6, “Using the Command Line Interface” • Section 2.7, “Selecting Ports in RUGGEDCOM ROS ” • Section 2.8, “Managing the Flash File System” • Section 2.9, “Accessing BIST Mode” • Section 2.10, “Managing SSH Public Keys”

Section 2.1 Connecting to ROS

This section describes the various methods for connecting the device.

CONTENTS • Section 2.1.1, “Connecting Directly” • Section 2.1.2, “Connecting via the Network”

Section 2.1.1 Connecting Directly

RUGGEDCOM ROS can be accessed through a direct RS-232 serial console connection for management and troubleshooting purposes. A console connection provides access to the console interface and CLI. To establish a console connection to the device, do the following: 1. Connect a workstation (either a terminal or computer running terminal emulation software) to the RS-232 serial console port on the device. For more information about the RS-232 serial console port, refer to the RS900 Installation Guide.

NOTE The baud rate for the device is printed on the chassis exterior near the RS-232 serial console port.

Connecting to ROS 29 Chapter 2 RUGGEDCOM ROS Using ROS User Guide

2. Configure the workstation as follows: • Speed (baud): 57600 • Data Bits: 8 • Parity: None • Flow Control: Off • Terminal ID: VT100 • Stop Bit: 1 3. Connect to the device. Once the connection is established, the login form appears. For more information about logging in to the device, refer to Section 2.2, “Logging In” .

Section 2.1.2 Connecting via the Network

RUGGEDCOM ROS can be accessed over the network either through a Web browser, terminal or a workstation running terminal emulation software.

Using a Web Browser Web browsers provide a secure connection to the Web interface for RUGGEDCOM ROS using the SSL (Secure Socket Layer) communication method. SSL encrypts traffic exchanged with its clients. The RUGGEDCOM ROS Web server guarantees that all communications with the client are private. If a client requests access through an insecure HTTP port, the client is automatically rerouted to the secure port. Access to the Web server through SSL will only be granted to clients that provide a valid user name and password. To establish a connection through a Web browser, do the following: 1. On the workstation being used to access the device, configure an Ethernet port to use an IP address falling within the subnet of the device. The default IP address is 192.168.0.1/24. For example, to configure the device to connect to one of the available Ethernet ports, assign an IP address to the Ethernet port on the workstation in the range of 192.168.0.3 to 192.168.0.254. 2. Open a Web browser. For a list of recommended Web browsers, refer to the section called “System Requirements” .

IMPORTANT! Upon connecting to the device, some Web browsers may report the Web server's certificate cannot be verified against any known certificates. This is expected behavior, and it is safe to instruct the browser to accept the certificate. Once the certificate is accepted, all communications with the Web server through that browser will be secure.

3. In the address bar, type the IP address for the port that is connected to the network. For example, to access the device using its factory default IP address, type https://192.168.0.1 and press Enter. Once the connection is established, the login screen for the Web interface appears. For more information about logging in to the device, refer to Section 2.2, “Logging In” . For more information about the Web interface, refer to Section 2.4, “Using the Web Interface” .

30 Connecting via the Network RUGGEDCOM ROS Chapter 2 User Guide Using ROS

Using a Terminal or Terminal Emulation Software A terminal or computer running terminal emulation software provides access to the console interface for RUGGEDCOM ROS through a Telnet, RSH (Remote Shell) or SSH (Secure Shell) service.

NOTE IP services can be restricted to control access to the device. For more information, refer to Section 3.9, “Configuring IP Services” .

To establish a connection through a terminal or terminal emulation software, do the following: 1. Select the service (i.e. Telnet, RSH or SSH). 2. Enter the IP address for the port that is connected to the network. 3. Connect to the device. Once the connection is established, the login form appears. For more information about logging in to the device, refer to Section 2.2, “Logging In” .

Section 2.2 Logging In

To log in to the device, do the following: 1. Connect to the device either directly or through a Web browser. For more information about how to connect to the device, refer to Section 2.1, “Connecting to ROS” . Once the connection is established, the login form appears.

1

2

Figure 2: SSH Login Screen (Console Interface) 1. User Name Box 2. Password Box

1 2

3

Figure 3: Login Screen (Web Interface) 1. Username Box 2. Password Box 3. Submit Button

Logging In 31 Chapter 2 RUGGEDCOM ROS Using ROS User Guide

NOTE The following default usernames and passwords are set on the device for each user type: Guest Operator Admin Username: guest Username: operator Username: admin Password: guest Password: operator Password: admin

CAUTION! To prevent unauthorized access to the device, make sure to change the default guest, operator, and admin passwords before commissioning the device. For more information about changing passwords, refer to Section 4.3, “Configuring Passwords” .

2. In the User Name field, type the username for an account setup on the device. 3. In the Password field, typ the password for the account. 4. Click Enter or click Submit (Web interface only).

Section 2.3 Logging Out

To log out of the device, navigate to the main screen and do the following: • To log out of the Console or secure shell interfaces, press CTRL + X. • To log out of the Web interface, click Logout.

1

Figure 4: Web Interface (Example) 1. Logout

NOTE If any pending configuration changes have not been committed, RUGGEDCOM ROS will request confirmation before discarding the changes and logging out of the device.

32 Logging Out RUGGEDCOM ROS Chapter 2 User Guide Using ROS

Section 2.4 Using the Web Interface

The Web interface is a Web-based Graphical User Interface (GUI) for displaying important information and controls in a Web browser. The interface is divided into three frames: the banner, the menu and the main frame.

1

2 3

Figure 5: Web Interface Layout (Example) 1. Top Frame 2. Side Frame 3. Main Frame

Frame Description

Top The top frame displays the system name for the device.

Side The side frame contains a logout option and a collapsible list of links that open various screens in the main frame. For information about logging out of RUGGEDCOM ROS, refer to Section 2.3, “Logging Out” .

Main The main frame displays the parameters and/or data related to the selected feature.

Each screen consists of a title, the current user's access level, parameters and/or data (in form or table format), and controls (e.g. add, delete, refresh, etc.). The title provides access to context-specific Help for the screen that provides important information about the available parameters and/or data. Click on the link to open the Help information in a new window. When an alarm is generated, an alarm notification replaces the current user's access level on each screen until the alarm is cleared. The notification indicates how many alarms are currently active. For more information about alarms, refer to Section 4.6, “Managing Alarms” .

Using the Web Interface 33 Chapter 2 RUGGEDCOM ROS Using ROS User Guide

1 3

2

4

Figure 6: Elements of a Typical Screen (Example) 1. Title 2. Parameters and/or Data 3. Access Level or Alarm Notification 4. Controls

NOTE If desired, the web interface can be disabled. For more information, refer to Section 4.5, “Enabling/ Disabling the Web Interface” .

Section 2.5 Using the Console Interface

The Console interface is a Graphical User Interface (GUI) organized as a series of menus. It is primarily accessible through a serial console connection, but can also be accessed through IP services, such as a Telnet, RSH (Remote Shell), SSH (Secure Shell) session, or SSH remote command execution.

NOTE IP services can be restricted to control access to the device. For more information, refer to Section 3.9, “Configuring IP Services” .

Each screen consists of a system identifier, the name of the current menu, and a command bar. Alarms are also indicated on each screen in the upper right corner.

34 Using the Console Interface RUGGEDCOM ROS Chapter 2 User Guide Using ROS

4

1 5

2

3

Figure 7: Console Interface (Example) 1. System Identification 2. Menus 3. Command Bar 4. Menu Name 5. Alarms Indicator

NOTE The system identifier is user configurable. For more information about setting the system name, refer to Section 4.1, “Configuring the System Information” .

Navigating the Interface Use the following controls to navigate between screens in the Console interface:

Enter Select a menu item and press this Enter to enter the sub-menu or screen beneath.

Esc Press Esc to return to the previous screen.

Configuring Parameters Use the following controls to select and configure parameters in the Console interface:

Up/Down Arrow Keys Use the up and down arrow keys to select parameters.

Enter Select a parameter and press Enter to start editing a parameter. Press Enter again to commit the change.

Esc When editing a parameter, press Esc to abort all changes.

Using the Console Interface 35 Chapter 2 RUGGEDCOM ROS Using ROS User Guide

Commands The command bar lists the various commands that can be issued in the Console interface. Some commands are specific to select screens. The standard commands include the following:

Ctrl + A Commits configuration changes made on the current screen.

NOTE Before exiting a screen, RUGGEDCOM ROS will automatically prompt the user to save any changes that have not been committed.

Ctrl + I Inserts a new record.

Ctrl + L Deletes a record.

Ctrl + S Opens the CLI interface.

Ctrl + X Terminates the current session. This command is only available from the main menu.

Ctrl + Z Displays important information about the current screen or selected parameter.

Section 2.6 Using the Command Line Interface

The Command Line Interface (CLI) offers a series of powerful commands for updating ROS, generating certificates/ keys, tracing events, troubleshooting and much more. It is accessed via the Console interface by pressing Ctrl-S.

CONTENTS • Section 2.6.1, “Available CLI Commands” • Section 2.6.2, “Tracing Events” • Section 2.6.3, “Executing Commands Remotely via RSH” • Section 2.6.4, “Using SQL Commands”

Section 2.6.1 Available CLI Commands

The following commands are available at the command line:

Command Description

alarms all Displays a list of available alarms. Optional and/or required parameters include: • all displays all available alarms

arp Displays the IP to MAC address resolution table.

clearalarms Clears all alarms.

clearethstats [ all | port ] Clears Ethernet statistics for one or more ports. Optional and/or required parameters include: • all clears statistics for all ports

36 Using the Command Line Interface RUGGEDCOM ROS Chapter 2 User Guide Using ROS

Command Description • port is a comma separated list of port numbers (e.g. 1,3-5,7)

clearlogs Clears the system and crash logs.

clrcblstats [ all | port ] Clears cable diagnostics statistics for one or more ports. Optional and/or required parameters include: • all clears statistics for all ports • port is a comma separated list of port numbers (e.g. 1,3-5,7)

clrstpstats Clears all spanning tree statistics.

cls Clears the screen.

dir Prints the directory listing.

exit Terminates the session.

factory Enables factory mode, which includes several factory-level commands used for testing and troubleshooting. Only available to admin users.

CAUTION! Misuse of the factory commands may corrupt the operational state of device and/or may permanently damage the ability to recover the device without manufacturer intervention.

flashfiles { info filename | A set of diagnostic commands to display information about the Flash filesystem and to defrag } defragment Flash memory. Optional and/or required parameters include: • info filename displays information about the specified file in the Flash file system • defrag defragments files in the Flash file system For more information about the flashfiles command, refer to Section 2.8, “Managing the Flash File System” .

flashleds timeout Flashes the LED indicators on the device for a specified number of seconds. Optional and/or required parameters include: • timeout is the number of seconds to flash the LED indicators. To stop the LEDs from flashing, set the timeout period to 0 (zero).

fpgacmd Provides access to the FPGA management tool for troubleshooting time synchronization.

help command Displays a brief description of the specified command. If no command is specified, it displays a list of all available commands, including a description for each. Optional and/or required parameters include: • command is the command name.

ipconfig Displays the current IP address, subnet mask and default gateway. This command provides the only way of determining these values when DHCP is used.

loaddflts Loads the factory default configuration.

login Logs in to the shell.

logout Logs out of the shell.

logs Displays syslog entries in CLI shell.

ping address { count | Sends an ICMP echo request to a remotely connected device. For each reply received, the timeout } round trip time is displayed. Use this command to verify connectivity to the next connected device. It is a useful tool for testing commissioned links. This command also includes the ability to send a specific number of pings with a specified time for which to wait for a response. Optional and/or required parameters include:

Available CLI Commands 37 Chapter 2 RUGGEDCOM ROS Using ROS User Guide

Command Description • address is the target IP address. • count is the number of echo requests to send. The default is 4. • timeout is the time in milliseconds to wait for each reply. The range is 2 to 5000 seconds. The default is 300 milliseconds.

NOTE The device to be pinged must support ICMP echo. Upon commencing the ping, an ARP request for the MAC address of the device is issued. If the device to be pinged is not on the same network as the device pinging the other device, the default gateway must be programmed.

purgemac Purges the MAC Addrtess table.

random Display seeds or random numbers.

reset Perform a hard reset of the switch.

resetport { all | ports } Resets one or more Ethernet ports, which may be useful for forcing re-negotiation of speed and duplex, or in situations where the link partner has latched into an inappropriate state. Optional and/or required parameters include: • all resets all ports • ports is a comma separated list of port numbers (e.g. 1,3-5,7)

rmon Displays the names of all RMON alarm eligible objects.

route Displays the gateway configuration.

sfp port { base | alarms | Displays SFP (Small Form Factor Pluggable) device information and diagnostics. If optional diag | calibr | thr | all | no or required parameters are not used, this command displays the base and extended parameter specified } information. Optional and/or required parameters include: • port is the port number for which the data are required • base displays the base information • alarms displays alarms and warning flags • diag displays measured data • calibr displays calibration data for external calibration • thr displays thresholds data • all displays all diagnostic data

sql { default | delete | help | Provides an SQL-like interface for manipulating all system configuration and status info | insert | save | select | parameters. All commands, clauses, table, and column names are case insensitive. update } Optional and/or required parameters include: • default sets all records in a table(s) to factory defaults • delete allows for records to be deleted from a table • help provides a brief description for any SQL command or clause • info displays a variety of information about the tables in the database • insert enables new records to be inserted into a table • save saves the database to non-volatile memory storage • select queries the dtabase and displays selected records • update enable existing records in a table to be updated For more information about the sql command, refer to Section 2.6.4, “Using SQL Commands” .

sshkeygen keytype N Generates new SSH keys in ssh.keys. Optional and/or required parameters include: • keytype is the type of key, either rsa or dsa • N is the number of bits in length. The allowable sizes are 1024, 2048 or 3072

38 Available CLI Commands RUGGEDCOM ROS Chapter 2 User Guide Using ROS

Command Description

sshpubkey List, remove and update key entries in sshpub.keys file.

sslkeygen keytype N Generates a new SSL certificate in ssl.crt. Optional and/or required parameters include: • keytype is the type of key, either rsa or ecc • N is the number of bits in length. For RSA keys, the allowable sizes are 1024, 2048 or 3072. For ECC keys, the allowable sizes are 192, 224, 256, 384, or 521.

telnet dest Opens a telnet session. Press Ctrl-C to close the session. Optional and/or required parameters include: • dest is the server's IP address

tftp { dest | cmd | fsource Opens a TFTP session. Press Ctrl-C to close the session. fdest | } Optional and/or required parameters include: • dest is the remote TFTP server's IP address • cmd is either put (upload) or get (download) • fsource is the source filename • fdest is the destination filename

trace Starts event tracing. Run trace ? for more help.

type filename Displays the contents of a text file. Optional and/or required parameters include: • filename is the name of the file to be read

version Prints the software version.

xmodem { send | receive } Opens an XModem session. filename Optional and/or required parameters include: • send sends the file to the client. • receive receives the file from the client. • filename is the name of the file to be read.

Section 2.6.2 Tracing Events

The CLI trace command provides a means to trace the operation of various protocols supported by the device. Trace provides detailed information, including STP packet decodes, IGMP activity and MAC address displays.

NOTE Tracing has been designed to provide detailed information to expert users. Note that all tracing is disabled upon device startup.

To trace an event, do the following: 1. Log in to the device as an admin user and access the CLI shell. For more information about accessing the CLI shell, refer to Section 2.6, “Using the Command Line Interface” . 2. Determine the protocols and associated options available by typing:

trace ?

If an option such as allon or alloff is required, determine which options are available for the desired protocol by typing:

Tracing Events 39 Chapter 2 RUGGEDCOM ROS Using ROS User Guide

trace protocol ?

NOTE If required, expand the trace scope by stringing protocols and their associated options together using a vertical bar (|).

3. Select the type of trace to run by typing:

trace protocol option Where: • protocol is the protocol to trace • option is the option to use during the trace Example:

>trace transport allon TRANSPORT: Logging is enabled 4. Start the trace by typing:

trace

Section 2.6.3 Executing Commands Remotely via RSH

The Remote Shell (RSH) facility can be used from a workstation to cause the product to act upon commands as if they were entered at the CLI prompt. The syntax of the RSH command is usually of the form:

rsh ipaddr –l auth_token command_string Where: • ipaddr is the address or resolved name of the device. • auth_token is the user name (i.e. guest, operator or admin) and corresponding password separated by a comma. For example, admin,secret. • command_string is the RUGGEDCOM ROS CLI command to execute. NOTE The access level (corresponding to the user name) selected must support the given command.

NOTE Any output from the command will be returned to the workstation submitting the command. Commands that start interactive dialogs (such as trace) cannot be used.

Section 2.6.4 Using SQL Commands

RUGGEDCOM ROS provides an SQL-like command facility that allows expert users to perform several operations not possible under the traditional Web or CLI interface. For instance:

40 Executing Commands Remotely via RSH RUGGEDCOM ROS Chapter 2 User Guide Using ROS

• Restoring the contents of a specific table, but not the whole configuration, to their factory defaults. • Search tables in the database for specific configurations. • Make changes to tables predicated upon existing configurations. When combined with RSH, SQL commands provide a means to query and configure large numbers of devices from a central location.

NOTE For a list of parameters available under the sql command, refer to Section 2.6.1, “Available CLI Commands” .

NOTE Read/write access to tables containing passwords or shared secrets is unavailable using SQL commands.

CONTENTS • Section 2.6.4.1, “Finding the Correct Table” • Section 2.6.4.2, “Retrieving Information” • Section 2.6.4.3, “Changing Values in a Table” • Section 2.6.4.4, “Resetting a Table” • Section 2.6.4.5, “Using RSH and SQL”

Section 2.6.4.1 Finding the Correct Table

Many SQL commands operate upon specific tables in the database, and require the table name to be specified. Navigating the menu system in the console interface to the desired menu and pressing Ctrl-Z displays the name of the table. The menu name and the corresponding database table name will be cited. Another way to find a table name is to type the following in the CLI:

sql info tables This command also displays menu names and their corresponding database table names depending upon the features supported by the device. For example:

Table Description ------alarms Alarms cpuDiags CPU Diagnostics ethPortCfg Port Parameters ethPortStats Ethernet Statistics ethPortStatus Port Status ipCfg IP Services

Section 2.6.4.2 Retrieving Information

The following describes various methods for retrieving information about tables and parameters.

Finding the Correct Table 41 Chapter 2 RUGGEDCOM ROS Using ROS User Guide

Retrieving Information from a Table Use the following command to display a summary of the parameters within a table, as well as their values:

sql select from table Where: • table is the name of the table Example:

>sql select from ipAddrtable

IP Address Subnet IfIndex IfStats IfTime IfName 172.30.146.88 255.255.224.0 1001 17007888 2994 vlan1

1 records selected

Retrieving Information About a Parameter from a Table Use the following command to retrieve information about a specific parameter from a table:

NOTE The parameter name must be the same as it is displayed in the menu system, unless the name contains spaces (e.g. ip address). Spaces must be replaced with underscores (e.g. ip_address) or the parameter name must be wrapped in double quotes (e.g. "ip address").

sql select parameter from table Where: • parameter is the name of the parameter • table is the name of the table Example:

>sql select "ip address" from ipSwitchIfCfg

IP Address 192.168.0.1

1 records selected

Retrieving Information from a Table Using the Where Clause Use the following command to display specific parameters from a table that have a specific value:

sql select from table where parameter = value Where: • table is the name of the table • parameter is the name of the parameter • value is the value of the parameter Example:

>sql select from ethportcfg where media = 1000T

42 Retrieving Information RUGGEDCOM ROS Chapter 2 User Guide Using ROS

Port Name ifName Media State AutoN Speed Dupx FlowCtrl LFI Alarm 1 Port 1 1 1000T Enabled On Auto Auto Off Off On 2 Port 2 2 1000T Enabled On Auto Auto Off Off On 3 Port 3 3 1000T Enabled On Auto Auto Off Off On 4 Port 4 4 1000T Enabled On Auto Auto Off Off On

4 records selected

Further refine the results by using and or or operators:

sql select from table where parameter = value [ { and | or } | parameter | = | value ...] Where: • table is the name of the table • parameter is the name of the parameter • value is the value of the parameter Example:

>sql select from ethportcfg where media = 1000T and State = enabled

Port Name ifName Media State AutoN Speed Dupx FlowCtrl LFI Alarm 1 Port 1 1 1000T Enabled On Auto Auto Off Off on 2 Port 2 2 1000T Enabled On Auto Auto Off Off On 3 Port 3 3 1000T Enabled On Auto Auto Off Off On 4 Port 4 4 1000T Enabled On Auto Auto Off Off On

4 records selected

Section 2.6.4.3 Changing Values in a Table

Use the following command to change the value of parameters in a table:

sql update table set parameter = value Where: • table is the name of the table • parameter is the name of the parameter • value is the value of the parameter Example:

>sql update iplcfg set IP_Address_Type = static 1 records updated

Conditions can also be included in the command to apply changes only to parameters that meet specific criteria. In the following example, flow control is enabled on ports that are operating in 100 Mbps full-duplex mode with flow control disabled:

>sql update ethportcfg set FlowCtrl = Off where ( Media = 100TX and FlowCtrl = On ) 2 records updated

Changing Values in a Table 43 Chapter 2 RUGGEDCOM ROS Using ROS User Guide

Section 2.6.4.4 Resetting a Table

Use the following command to reset a table back to its factory defaults:

sql default into table Where: • table is the name of the table

Section 2.6.4.5 Using RSH and SQL

The combination of remote shell scripting and SQL commands offers a means to interrogate and maintain a large number of devices. Consistency of configuration across sites may be verified by this method. The following presents a simple example where the devices to interrogate are drawn from the file Devices:

C:> type Devices 10.0.1.1 10.0.1.2

C:\> for /F %i in (devices) do rsh %i -l admin,admin sql select from ipAddrtable

C:\>rsh 10.0.1.1 -l admin,admin sql select from ipAddrtable

IP Address Subnet IfIndex IfStats IfTime IfName 192.168.0.31 255.255.255.0 1001 274409096 2218 vlan1

1 records selected

C:\>rsh 10.0.1.2 -l admin,admin sql select from ipAddrtable 0 records selected C:\

Section 2.7 Selecting Ports in RUGGEDCOM ROS

Many features in ROS can be configured for one or more ports on the device. The following describes how to specify a single port, a range of ports, or all ports . Select a single port by specifying the port number:

2

Select a range of ports using a dash (-) between the first port and the last port in the list:

1-4

Select multiple ports by defining a comma-separated list:

1,4,6,9

44 Resetting a Table RUGGEDCOM ROS Chapter 2 User Guide Using ROS

Use the All option to select all ports in the device, or, if available, use the None option to select none of the ports.

Section 2.8 Managing the Flash File System

The following section describes how to manage the flash file system.

CONTENTS • Section 2.8.1, “Viewing a List of Flash Files” • Section 2.8.2, “Viewing Flash File Details” • Section 2.8.3, “Defragmenting the Flash File System”

Section 2.8.1 Viewing a List of Flash Files

To view a list of files currently stored in Flash memory, do the following: 1. Log in to the device as an admin user and access the CLI shell. For more information about accessing the CLI shell, refer to Section 2.6, “Using the Command Line Interface” . 2. Type flashfiles. A list of files currently in Flash memory is displayed, along with their locations and the amount of memory they consume. For example:

>flashfiles ------Filename Base Size Sectors Used ------boot.bin 00000000 110000 0-16 1095790 main.bin 00110000 140000 17-36 1258403 fpga.xsvf 00250000 010000 37-37 55882 syslog.txt 00260000 140000 38-57 19222 ssh.keys 003A0000 010000 58-58 915 ssl.crt 003B0000 010000 59-59 1970 banner.txt 003C0000 010000 60-60 256 crashlog.txt 003D0000 010000 61-61 256 config.bak 003E0000 010000 62-62 15529 config.csv 003F0000 008000 63-63 15529 factory.txt 003FC000 004000 66-66 407 ------

Section 2.8.2 Viewing Flash File Details

To view the details of a file currently stored in Flash memory, do the following: 1. Log in to the device as an admin user and access the CLI shell. For more information about accessing the CLI shell, refer to Section 2.6, “Using the Command Line Interface” . 2. Display information about a file by typing:

Managing the Flash File System 45 Chapter 2 RUGGEDCOM ROS Using ROS User Guide

flashfiles info filename Where: • filename is the name of the file stored in Flash memory Details, similar to the following, are displayed.

>flashfiles info main.bin

Flash file information for main.bin: Header version : 4 Platform : ROS-CF52

File name : main.bin Firmware version : v4.3.0 Build date : Sep 27 2014 15:50 File length : 2624659 Board IDs : 3d Header CRC : 73b4 Header CRC Calc : 73b4 Body CRC : b441 Body CRC Calc : b441

Section 2.8.3 Defragmenting the Flash File System

The flash memory is defragmented automatically whenever there is not enough memory available for a binary upgrade. However, fragmentation can occur whenever a new file is uploaded to the unit. Fragmentation causes sectors of available memory to become separated by ones allocated to files. In some cases, the total available memory might be sufficient for a binary upgrade, but that memory may not be available in one contiguous region. To defragment the flash memory, do the following: 1. Log in to the device as an admin user and access the CLI shell. For more information about accessing the CLI shell, refer to Section 2.6, “Using the Command Line Interface” . 2. Defragment the flash memory by typing:

flashfiles defrag

Section 2.9 Accessing BIST Mode

BIST (Built-In-Self-Test) mode is used by service technicians to test and configure internal functions of the device. It should only be accessed for troubleshooting purposes.

CAUTION! Mechanical hazard – risk of damage to the device. Excessive use of BIST functions may cause increase wear on the device, which may void the warranty. Avoid using BIST functions unless instructed by a Siemens Customer Support representative.

To access BIST mode, do the following:

46 Defragmenting the Flash File System RUGGEDCOM ROS Chapter 2 User Guide Using ROS

IMPORTANT! Do not connect the device to the network when it is in BIST mode. The device will generate excess multicast traffic in this mode.

1. Disconnect the device from the network. 2. Connect to RUGGEDCOM ROS through the RS-232 console connection and a terminal application. For more information, refer to Section 2.1.1, “Connecting Directly” . 3. Reset the device. For more information, refer to Section 3.12, “Resetting the Device” . 4. During the boot up sequence, press Ctrl-C when prompted. The command prompt for BIST appears.

>

5. Type help to view a list of all available options under BIST.

Section 2.10 Managing SSH Public Keys

RUGGEDCOM ROS allows admin users to list, add and delete SSH public keys. Public keys are added as non-volatile storage (i.e. flash) files on RUGGEDCOM ROS devices, and are retrieved at the time of SSH client authentication.

CONTENTS • Section 2.10.1, “Adding a Public Key” • Section 2.10.2, “Viewing a List of Public Keys” • Section 2.10.3, “Updating a Public Key” • Section 2.10.4, “Deleting a Public Key”

Section 2.10.1 Adding a Public Key

Admin users can add one or more public keys to RUGGEDCOM ROS. Public keys are stored in a flash file, called sshpub.keys. The sshpub.keys file consists of ssh user public key entries. Similar to the config.csv file, each entry must be separated by an empty line. An entry has two components. They are, in sequence: • Header • Key The header contains the parameters of the entry, separated by comma. The parameters are, in sequence: • ID: A number between 0 and 9999 • Entry type: UserKey • Access Level: (Admin, Operator or Guest) • Revocation Status: active/inactive (always active for keys) • User Name: This is the client's user name (not the RUGGEDCOM ROS user name). This will be used by clients to later SSH into the RUGGEDCOM ROS device.

Managing SSH Public Keys 47 Chapter 2 RUGGEDCOM ROS Using ROS User Guide

The key must be in RFC4716 or PEM format, with any of the following header and footer lines:

-----BEGIN PUBLIC KEY------END PUBLIC KEY-----

-----BEGIN SSH2 PUBLIC KEY------END SSH2 PUBLIC KEY-----

-----BEGIN RSA PUBLIC KEY------END RSA PUBLIC KEY-----

The following is an example of a valid entry in the sshpub.keys file in PEM format:

1,userkey,admin,active,alice ---- BEGIN SSH2 PUBLIC KEY ---- AAAAB3NzaC1yc2EAAAABIwAAAQEA4mRrqfk+RKXnmGRvzMyWVDsbq5VwpGGrlLQYCrjVEa NdbXsphqYKop8V5VUeXFRAUFzOy82yk8TF/5JxGPWq6wRNjhnYR7IY2AiMBq0+K8XeURl/ z5K2XNRjnqTZSFwkhaUVJeduvjGgOlNN4yvgUwF3n0idU9k3E1q/na+LmYIeGhOwzCqoAc ipHAdR4fhD5u0jbmvjv+gDikTSZIbj9eFJfP09ekImMLHwbBry0SSBpqAKbwVdWEXIKQ47 zz7ao2/rs3rSV16IXSq3Qe8VZh2irah0Md6JFMOX2qm9fo1I62q1DDgheCOsOiGPf4xerH rI2cs6FT31rAdx2JOjvw== ---- END SSH2 PUBLIC KEY ---- The following is an example of a valid entry in the sshpub.keys file in in RFC4716 format:

2,userkey,admin,active,bob ssh-rsa AAAAB3NzaC1yc2EAAAADAQABAAABAQDH0NivR8zzbTxlecvFPzR/ GR24NrRJa0Lc7scNsWRgi0XulHuGrRLRB5RoQ39+spdig88Y8CqhRI49XJx7uLJe0Su3RvyNYz1jkdSwHq2hSZCpukJxJ6CK95Po/ sVa5Gq2gMaHowiYDSkcx+AJywzK/eM6i/jc125lRxFPdfkj74u+ob3PCvmIWz5z3WAJBrQU1IDPHDets511WMu8O9/ mAPZRwjqrWhRsqmcXZuv5oo54wIopCAZSo20SPzM2VmXFuUsEwDkvYMXLJK1koJPbDjH7yFFC7mwK2eMU/ oMFFn934cbO5N6etsJSvplYQ4pMCw6Ok8Q/bB5cPSOa/rAt bob@work

IMPORTANT! The content of the sshaddpub.keys file must follow the same syntax as the sshpub.keys file.

RUGGEDCOM ROS allows only 16 user key entries to be stored. Each key entry must meet the following limits: • Key type must be either RSA 2048 bits or RSA 3072 bits • Key size must not exceed 4000 base64 encoded characters • Entry Type in the header must not exceed 8 ASCII characters • Access Level in the header must not exceed 8 ASCII characters (operator is maximum) • Revocation status in the header must not exceed 8 ASCII characters (inactive is maximum) • User Name must not exceed 12 ASCII characters There are two ways to update sshpub.keys. Users can either upload a locally-created file directly to the sshpub.keys file, which will replace the content in flash with the uploaded content. Or, users can upload a locally- created file to the sshaddpub.keys file, which will keep the existing entries in the sshpub.keys file and append the new entries. To add keys, do the following: 1. Create a public key file via a host computer. 2. Transfer the public key file to the device using SFTP or Xmodem. For more information about transferring files, refer to Section 3.4, “Uploading/Downloading Files” . 3. Log in to the device as an admin user and access the CLI shell. For more information about accessing the CLI shell, refer to Section 2.6, “Using the Command Line Interface” .

48 Adding a Public Key RUGGEDCOM ROS Chapter 2 User Guide Using ROS

4. Check the system log to make sure the files were properly transferred. For more information about viewing the system log, refer to Section 3.5.1, “Viewing Local Logs” .

Section 2.10.2 Viewing a List of Public Keys

Admin users can view a list of existing public keys on the device. To view public keys, do the following: 1. Log in to the device as an admin user and access the CLI shell. For more information about accessing the CLI shell, refer to Section 2.6, “Using the Command Line Interface” . 2. At the CLI prompt, type:

sshpubkey list A list of public keys will appear, including their key ID, access level, revocation status, user name and key fingerprint.

Section 2.10.3 Updating a Public Key

Admin users can update public keys. To update public keys, do the following: 1. Log in to the device as an admin user and access the CLI shell. For more information about accessing the CLI shell, refer to Section 2.6, “Using the Command Line Interface” . 2. At the CLI prompt, type:

sshpubkey list A list of public keys will appear, including their key ID, access level, revocation status, user name and key fingerprint. 3. Type the following commands to update the public keys: Command Description

sshpubkey update_id current_ID Updates the ID of user public key. new_ID NOTE The user public key ID must be a number between 0 and 9999.

• current_ID is the ID currently assigned to the public key • new_ID is the ID that will be used to identify the public key going forward

sshpubkey update_al AL Updates the access level of a user public key. • AL is the access level (admin, operator or guest) of the public key to be updated

sshpubkey update_rs RS Updates the revocation status (active, inactive) of a user public key. • RS is the revocation status of the public key to be updated

sshpubkey update_un UN Updates the user name of a user public key. • UN is the user name of the public key to be updated

Viewing a List of Public Keys 49 Chapter 2 RUGGEDCOM ROS Using ROS User Guide

Section 2.10.4 Deleting a Public Key

Admin users can delete one or more public keys. To delete a public key, do the following: 1. Log in to the device as an admin user and access the CLI shell. For more information about accessing the CLI shell, refer to Section 2.6, “Using the Command Line Interface” . 2. At the CLI prompt, type:

sshpubkey list A list of public keys will appear, including access level, revocation status, user name and key fingerprint. 3. Type the following commands to delete the public key(s): Command Description

sshpubkey remove ID Removes a key from the non-volatile storage. • ID is the ID of the public key to be removed

50 Deleting a Public Key RUGGEDCOM ROS Chapter 3 User Guide Device Management

Device Management

This chapter describes how to configure and manage the device and its components, such as module interfaces, logs and files.

NOTE For information about how to configure the device to work with a network, refer to Chapter 5, Setup and Configuration .

CONTENTS • Section 3.1, “Viewing Product Information” • Section 3.2, “Viewing CPU Diagnostics” • Section 3.3, “Restoring Factory Defaults” • Section 3.4, “Uploading/Downloading Files” • Section 3.5, “Managing Logs” • Section 3.6, “Managing Ethernet Ports” • Section 3.7, “Managing IP Interfaces” • Section 3.8, “Managing IP Gateways” • Section 3.9, “Configuring IP Services” • Section 3.10, “Managing Remote Monitoring” • Section 3.11, “Upgrading/Downgrading Firmware” • Section 3.12, “Resetting the Device” • Section 3.13, “Decommissioning the Device”

Section 3.1 Viewing Product Information

During troubleshooting or when ordering new devices, Siemens personnel may request specific information about the device, such as the model, order code or serial number. To view information about the device, navigate to Diagnostics » View Product Information . The Product Information form appears.

Viewing Product Information 51 Chapter 3 RUGGEDCOM ROS Device Management User Guide

1

2

3

4

5

6

7

8

9

Figure 8: Product Information Form (Example) 1. MAC Address Box 2. Order Code Box 3. Classification Box 4. Serial Number Box 5. Boot Version Box 6. Main Version Box 7. Required Boot Box 8. Hardware ID Box 9. Reload Button

This screen displays the following information:

Parameter Description

MAC Address Synopsis: ##-##-##-##-##-## where ## ranges 0 to FF Shows the unique MAC address of the device.

Order Code Synopsis: Any 57 characters Shows the order code of the device.

Classification Synopsis: Any 15 characters Provides system classification. The value Controlled indicates the main firmware is a Controlled release. The value Non-Controlled indicates the main firmware is a Non-Controlled release. The Controlled main firmware can run on Controlled units, but it can not run on Non-Controlled units. The Non-Controlled main firmware can run on both Controlled and Non- Controlled units.

Serial Number Synopsis: Any 31 characters Shows the serial number of the device.

Boot Version Synopsis: Any 47 characters Shows the version and the build date of the boot loader software.

Main Version Synopsis: Any 47 characters Shows the version and build date of the main operating system software.

Required Boot Synopsis: Any 15 characters Shows the minimum boot software loader version required by running main.

Hardware ID Synopsis: { RSMCPU (40-00-0008 Rev B1), RSMCPU2 (40-00-0026 Rev A1), RS400 (40-00-0010 Rev B2), RMC30, RS900 (40-00-0025 Rev B1), RS900 (40-00-0032 Rev B1), RS1600M, RS400 (40-00-0010

52 Viewing Product Information RUGGEDCOM ROS Chapter 3 User Guide Device Management

Parameter Description Rev C1), RSG2100, RS900G, RSG2200, RS969, RS900 (v2, 40-00-0066), RS900 (v2, 40-00-0067), , RS416 (40-00-0078), RMC30 (v2), RS930 (40-00-0089), RS969 (v2, 40-00-0090), RS910 (40-00-0091-001 Rev A), RS920L (40-00-0102-001 Rev A), RS940G (40-00-0097-000 Rev A), RSi80X series CPU board, RSG2300, RS416v2, ... } Shows the type, part number, and revision level of the hardware.

Section 3.2 Viewing CPU Diagnostics

To view CPU diagnostic information useful for troubleshooting hardware and software performance, navigate to Diagnostics » View CPU Diagnostics . The CPU Diagnostics form appears.

1

2

3

4

5

6

7

8

9 10

Figure 9: CPU Diagnostics Form 1. Running Time Box 2. Total Powered Time Box 3. CPU Usage Box 4. RAM Total Box 5. RAM Free Box 6. RAM Low Watermark Box 7. Temperature Box 8. Free Rx Bufs Box 9. Free Tx Bufs Box 10. Reload Button

This screen displays the following information:

Parameter Description

Running Time Synopsis: DDDD days, HH:MM:SS The amount of time since the device was last powered on.

Total Powered time Synopsis: DDDD days, HH:MM:SS The cumulative powered up time of the device.

CPU Usage Synopsis: 0.0 to 100.0% The percentage of available CPU cycles used for device operation as measured over the last second.

RAM Total Synopsis: 0 to 4294967295

Viewing CPU Diagnostics 53 Chapter 3 RUGGEDCOM ROS Device Management User Guide

Parameter Description The total size of RAM in the system.

RAM Free Synopsis: 0 to 4294967295 The total size of RAM still available.

RAM Low Watermark Synopsis: 0 to 4294967295 The size of RAM that have never been used during the system runtime.

Temperature Synopsis: -32768 to 32767 C The temperature on CPU board.

Free Rx Bufs Synopsis: 0 to 4294967295 Free Rx Buffers.

Free Tx Bufs Synopsis: 0 to 4294967295 Free Tx Buffers.

Section 3.3 Restoring Factory Defaults

The device can be completely or partially restored to its original factory default settings. Excluding groups of parameters from the factory reset, such as those that affect basic connectivity and SNMP management, is useful when communication with the device is still required during the reset. The following categories are not affected by a selective configuration reset: • IP Interfaces • IP Gateways • SNMP Users • SNMP Security to Group Maps • SNMP Access • RUGGEDCOM Discovery Protocol™ (RCDP) In addition, the following categories are not affected by a full or selective configuration reset: • Time Zone • DST Offset • DST Rule To restore factory defaults, do the following: 1. Navigate to Diagnostics » Load Factory Defaults . The Load Factory Defaults form appears.

54 Restoring Factory Defaults RUGGEDCOM ROS Chapter 3 User Guide Device Management

1

2 3

Figure 10: Load Factory Defaults Form 1. Defaults Choice List 2. Apply Button 3. Reload

2. Configure the following parameter(s) as required:

NOTE If the VLAN ID for the Management IP interface is not 1, setting Defaults Choice to Selected will automatically set it to 1.

Parameter Description

Defaults Choice Synopsis: { None, Selected, All } Setting some records like IP Interfaces management interface, default gateway, SNMP settings to default value would cause switch not to be accessible with management applications. This parameter allows user to choose to load defaults to Selected tables, which would preserve configuration for tables that are critical for switch management applications, or to force All tables to default settings.

3. Click Apply.

Section 3.4 Uploading/Downloading Files

Files can be transferred between the device and a host computer using any of the following methods: • Xmodem using the CLI shell over a Telnet or RS-232 console session • TFTP client using the CLI shell in a console session and a remote TFTP server • TFTP server from a remote TFTP client • SFTP (secure FTP over SSH) from a remote SFTP client

IMPORTANT! Scripts can be used to automate the management of files on the device. However, depending on the size of the target file(s), a delay between any concurrent write and read commands may be required, as the file may not have been fully saved before the read command is issued. A general delay of five seconds is recommended, but testing is encouraged to optimize the delay for the target file(s) and operating environment.

Uploading/Downloading Files 55 Chapter 3 RUGGEDCOM ROS Device Management User Guide

NOTE The contents of the internal file system are fixed. New files and directories cannot be created, and existing files cannot be deleted. Only the files that can be uploaded to the device can be overwritten.

Files that may need to be uploaded or downloaded include: • main.bin – the main RUGGEDCOM ROS application firmware image • boot.bin – the boot loader firmware image • fpga.xsvf – the FPGA firmware binary image • config.csv – the complete configuration database, in the form of a comma-delimited ASCII text file • factory.txt – Contains the MAC address, order code and serial number. Factory data must be signed. • banner.txt – contains text that appears on the login screen

CONTENTS • Section 3.4.1, “Uploading/Downloading Files Using XMODEM” • Section 3.4.2, “Uploading/Downloading Files Using a TFTP Client” • Section 3.4.3, “Uploading/Downloading Files Using a TFTP Server” • Section 3.4.4, “Uploading/Downloading Files Using an SFTP Server”

Section 3.4.1 Uploading/Downloading Files Using XMODEM

To updload or download a file using XMODEM, do the following:

NOTE This method requires a host computer that has terminal emulation or Telnet software installed and the ability to perform XMODEM transfers.

NOTE Xmodem transfers can only be performed through the serial console, which is authenticated during login.

1. Establish a direct connection between the device and the host computer. For more information, refer to Section 2.1.1, “Connecting Directly” . 2. Log in to the device as an admin user and access the CLI shell. For more information about accessing the CLI shell, refer to Section 2.6, “Using the Command Line Interface” .

NOTE The send option sends files to the host computer, while the receive option pulls files from the host computer.

3. At the CLI prompt, type:

xmodem [ send | receive ] filename Where: • filename is the name of the file (i.e. main.bin)

56 Uploading/Downloading Files Using XMODEM RUGGEDCOM ROS Chapter 3 User Guide Device Management

NOTE If available in the terminal emulation or Telnet software, select the XModem 1K protocol for transmission over the standard XModem option.

4. When the device responds with Press Ctrl-X to cancel , launch the XMODEM transfer from the host computer. The device will indicate when the transfer is complete. The following is an example from the CLI shell of a successful XMODEM file transfer:

>xmodem receive main.bin Press Ctrl-X to cancel Receiving data now ...C Received 1428480 bytes. Closing file main.bin ... main.bin transferred successfully

Section 3.4.2 Uploading/Downloading Files Using a TFTP Client

To updload or download a file using a TFTP client, do the following:

IMPORTANT! TFTP does not define an authentication scheme. Any use of the TFTP client or server is considered highly insecure.

NOTE This method requires a TFTP server that is accessible over the network.

1. Identify the IP address of the computer running the TFTP server. 2. Establish a direct connection between the device and a host computer. For more information, refer to Section 2.1.1, “Connecting Directly” . 3. Log in to the device as an admin user and access the CLI shell. For more information about accessing the CLI shell, refer to Section 2.6, “Using the Command Line Interface” . 4. At the CLI prompt, type:

tftp address [ get | put ] source-filename destination-filename Where: • get copies files from the host computer to the device • put copies files from the device to the host computer • address is the IP address of the computer running the TFTP server • source-filename is the name of the file to be transferred • destination-filename is the name of the file (on the device or the TFTP server) that will be replaced during the transfer The following is an example of a successful TFTP client file transfer:

>tftp 10.0.0.1 get ROS-CF52_Main_v3.7.0.bin main.bin TFTP CMD: main.bin transfer . Please wait, closing file ...

Uploading/Downloading Files Using a TFTP Client 57 Chapter 3 RUGGEDCOM ROS Device Management User Guide

TFTP CMD: main.bin loading succesful.

Section 3.4.3 Uploading/Downloading Files Using a TFTP Server

To updload or download a file using a TFTP server, do the following:

IMPORTANT! TFTP does not define an authentication scheme. Any use of the TFTP client or server is considered highly insecure.

NOTE This method requires a host computer that has TFTP server software installed.

IMPORTANT! Interaction with TFTP servers is strictly controlled within the device to prevent unauthorized access. Make sure the device is configured to accept the TFTP connection. For more information, refer to Section 3.9, “Configuring IP Services” .

1. Establish a direct connection between the device and the host computer. For more information, refer to Section 2.1.1, “Connecting Directly” . 2. Initialize the TFTP server on the host computer and launch the TFTP transfer. The server will indicate when the transfer is complete. The following is an example of a successful TFTP server exchange:

C:\>tftp -i 10.1.0.1 put C:\files\ROD-CF52_Main_v3.7.0.bin main.bin Transfer successful: 1428480 bytes in 4 seconds, 375617 bytes/s

Section 3.4.4 Uploading/Downloading Files Using an SFTP Server

SFTP (Secure File Transfer Protocol) is a file transfer mechanism that uses SSH to encrypt every aspect of file transfer between a networked client and server.

NOTE The device does not have an SFTP client and, therefore, can only receive SFTP files from an external source. SFTP requires authentication for the file transfer.

To updload or download a file using an SFTP server, do the following:

NOTE This method requires a host computer that has SFTP client software installed.

1. Establish an SFTP connection between the device and the host computer. 2. Launch the SFTP transfer. The client will indicate when the transfer is complete. The following is an example of a successful SFTP server exchange:

58 Uploading/Downloading Files Using a TFTP Server RUGGEDCOM ROS Chapter 3 User Guide Device Management

user@host$ sftp admin@ros_ip Connecting to ros_ip... admin@ros_ip's password: sftp> put ROS-CF52_Main_v3-7-0.bin main.bin Uploading ROS-CF52_Main_v3-7-0.bin to /main.bin ROS-CF52_Main_v3-7-0.bin 100% 2139KB 48.6KB/s 00:44 sftp>

Section 3.5 Managing Logs

The crash (crashlog.txt) and system (syslog.txt) log files contain historical information about events that have occurred during the operation of the device. The crash log contains debugging information related to problems that might have resulted in unplanned restarts of the device or which may effect the operation of the device. A file size of 0 bytes indicates that no unexpected events have occurred. The system log contains a record of significant events including startups, configuration changes, firmware upgrades and database re-initializations due to feature additions. The system log will accumulate information until it is full, holding approximately 2 MB of data.

CONTENTS • Section 3.5.1, “Viewing Local Logs” • Section 3.5.2, “Clearing Local Logs” • Section 3.5.3, “Configuring the Local System Log” • Section 3.5.4, “Managing Remote Logging”

Section 3.5.1 Viewing Local Logs

The local crash and system logs can both be downloaded from the device and viewed in a text editor. For more information about downloading log files, refer to Section 3.4, “Uploading/Downloading Files” . To view the system log through the Web interface, navigate to Diagnostics » View System Log . The syslog.txt form appears.

Figure 11: syslog.txt Form

Managing Logs 59 Chapter 3 RUGGEDCOM ROS Device Management User Guide

Section 3.5.2 Clearing Local Logs

To clear both the local crash and system logs, log in to the CLI shell and type:

clearlogs To clear only the local system log, log in to the Web interface and do the following: 1. Navigate to Diagnostics » Clear System Log . The Clear System Log form appears.

1

Figure 12: Clear System Log Form 1. Confirm Button

2. Click Confirm.

Section 3.5.3 Configuring the Local System Log

To configure the severity level for the local system log, do the following:

NOTE For maximum reliability, use remote logging. For more information, refer to Section 3.5.4, “Managing Remote Logging” .

1. Navigate to Administration » Configure Syslog » Configure Local Syslog . The Local Syslog form appears.

1

2 3

Figure 13: Local Syslog Form 1. Local Syslog Level 2. Apply Button 3. Reload Button

2. Configure the following parameter(s) as required:

60 Clearing Local Logs RUGGEDCOM ROS Chapter 3 User Guide Device Management

Parameter Description

Local Syslog Level Synopsis: { EMERGENCY, ALERT, CRITICAL, ERROR, WARNING, NOTICE, INFORMATIONAL, DEBUGGING } Default: INFORMATIONAL The severity of the message that has been generated. Note that the severity level selected is considered the minimum severity level for the system. For example, if ERROR is selected, the system sends any syslog messages generated by Error, Critical, Alert and Emergency.

3. Click Apply.

Section 3.5.4 Managing Remote Logging

In addition to the local system log maintained on the device, a remote system log can be configured as well to collect important event messages. The syslog client resides on the device and supports up to 5 collectors (or syslog servers). The remote syslog protocol, defined in RFC 3164, is a UDP/IP-based transport that enables the device to send event notification messages across IP networks to event message collectors, also known as syslog servers. The protocol is designed to simply transport these event messages from the generating device to the collector(s).

CONTENTS • Section 3.5.4.1, “Configuring the Remote Syslog Client” • Section 3.5.4.2, “Viewing a List of Remote Syslog Servers” • Section 3.5.4.3, “Adding a Remote Syslog Server” • Section 3.5.4.4, “Deleting a Remote Syslog Server”

Section 3.5.4.1 Configuring the Remote Syslog Client

To configure the remote syslog client, do the following: 1. Navigate to Administration » Configure Syslog » Configure Remote Syslog Client . The Remote Syslog Client form appears.

Managing Remote Logging 61 Chapter 3 RUGGEDCOM ROS Device Management User Guide

1

2 3

Figure 14: Remote Syslog Client Form 1. UDP Port 2. Apply Button 3. Reload Button

2. Configure the following parameter(s) as required:

Parameter Description

UDP Port Synopsis: 1025 to 65535 or { 514 } Default: 514 The local UDP port through which the client sends information to the server(s).

3. Click Apply.

Section 3.5.4.2 Viewing a List of Remote Syslog Servers

To view a list of known remote syslog servers, navigate to Administration » Configure Syslog » Configure Remote Syslog Server . The Remote Syslog Server table appears.

Figure 15: Remote Syslog Server Table

If remote syslog servers have not been configured, add the servers as needed. For more information, refer to Section 3.5.4.3, “Adding a Remote Syslog Server” .

62 Viewing a List of Remote Syslog Servers RUGGEDCOM ROS Chapter 3 User Guide Device Management

Section 3.5.4.3 Adding a Remote Syslog Server

RUGGEDCOM ROS supports up to 5 remote syslog servers (or collectors). Similar to the local system log, a remote system log server can be configured to log information at a specific severity level. Only messages of a severity level equal to or greater than the specified severity level are written to the log. To add a remote syslog server to the list of known servers, do the following: 1. Navigate to Administration » Configure Syslog » Configure Remote Syslog Server . The Remote Syslog Server table appears.

1

Figure 16: Remote Syslog Server Table 1. InsertRecord

2. Click InsertRecord. The Remote Syslog Server form appears.

1

2

3

4

5 7

6

Figure 17: Remote Syslog Server Form 1. IP Address Box 2. UDP Port Box 3. Facility Box 4. Severity Box 5. Apply Button 6. Delete Button 7. Reload Button

3. Configure the following parameter(s) as required:

Parameter Description

IP Address Synopsis: ###.###.###.### where ### ranges from 0 to 255 Syslog server IP Address.

UDP Port Synopsis: 1025 to 65535 or { 514 }

Adding a Remote Syslog Server 63 Chapter 3 RUGGEDCOM ROS Device Management User Guide

Parameter Description Default: 514 The UDP port number on which the remote server listens.

Facility Synopsis: { USER, LOCAL0, LOCAL1, LOCAL2, LOCAL3, LOCAL4, LOCAL5, LOCAL6, LOCAL7 } Default: LOCAL7 Syslog Facility is one information field associated with a syslog message. The syslog facility is the application or operating system component that generates a log message. ROS map all syslog logging information onto a single facility which is configurable by user to facilitate remote syslog server.

Severity Synopsis: { EMERGENCY, ALERT, CRITICAL, ERROR, WARNING, NOTICE, INFORMATIONAL, DEBUGGING } Default: DEBUGGING The severity level is the severity of the message that has been generated. Please note that the severity level user select is accepted as the minimum severity level for the system. For example, if user selects the severity level as 'Error' then the system send any syslog message originated by Error, Critical, Alert and Emergency.

4. Click Apply.

Section 3.5.4.4 Deleting a Remote Syslog Server

To delete a remote syslog server from the list of known servers, do the following: 1. Navigate to Administration » Configure Syslog » Configure Remote Syslog Server . The Remote Syslog Server table appears.

Figure 18: Remote Syslog Server Table

2. Select the server from the table. The Remote Syslog Server form appears.

64 Deleting a Remote Syslog Server RUGGEDCOM ROS Chapter 3 User Guide Device Management

1

2

3

4

5 7

6

Figure 19: Remote Syslog Server Form 1. IP Address Box 2. UDP Port Box 3. Facility Box 4. Severity Box 5. Apply Button 6. Delete Button 7. Reload Button

3. Click Delete.

Section 3.6 Managing Ethernet Ports

The following section describes how to set up and manage Ethernet ports.

NOTE For information about configuring remote monitoring for Ethernet ports, refer to Section 3.10, “Managing Remote Monitoring” .

CONTENTS • Section 3.6.1, “Controller Protection Through Link Fault Indication (LFI)” • Section 3.6.2, “Viewing the Status of Ethernet Ports” • Section 3.6.3, “Viewing Statistics for All Ethernet Ports” • Section 3.6.4, “Viewing Statistics for Specific Ethernet Ports” • Section 3.6.5, “Clearing Statistics for Specific Ethernet Ports” • Section 3.6.6, “Configuring an Ethernet Port” • Section 3.6.7, “Configuring Port Rate Limiting” • Section 3.6.8, “Configuring Port Mirroring” • Section 3.6.9, “Configuring Link Detection” • Section 3.6.10, “Detecting Cable Faults”

Managing Ethernet Ports 65 Chapter 3 RUGGEDCOM ROS Device Management User Guide

• Section 3.6.11, “Resetting Ethernet Ports”

Section 3.6.1 Controller Protection Through Link Fault Indication (LFI)

Modern industrial controllers often feature backup Ethernet ports used in the event of a link failure. When these interfaces are supported by media (such as fiber) that employ separate transmit and receive paths, the interface can be vulnerable to failures that occur in only one of the two paths. Consider for instance two switches (A and B) connected to a controller. Switch A is connected to the main port on the controller, while Switch B is connected to the backup port, which is shut down by the controller while the link with Switch A is active. Switch B must forward frames to the controller through Switch A.

1 2

3 4

5

Figure 20: Example 1. Switch A 2. Switch B 3. Main Transmit Path 4. Backup Transmit Path 5. Controller

If the transmit path from the controller to Switch A fails, Switch A still generates a link signal to the controller through the receive path. The controller still detects the link with Switch A and does not failover to the backup port. This situation illustrates the need for a notification method that tells a link partner when the link integrity signal has stopped. Such a method natively exists in some link media, but not all.

100Base-TX, 1000Base-T, 1000Base-X Includes a built-in auto-negotiation feature (i.e. a special flag called Remote Fault Indication is set in the transmitted auto-negotation signal).

100Base-FX Links Includes a standard Far-End-Fault-Indication (FEFI) feature defined by the IEEE 802.3 standard for this link type. This feature includes: • Transmitting FEFI Transmits a modified link integrity signal in case a link failure is detected (i.e. no link signal is received from the link partner) • Detecting FEFI Indicates link loss in case an FEFI signal is received from the link partner

10Base-FL LInks No standard support.

10Base-FL links do not have a native link partner notification mechanism and FEFI support in 100Base-FX links is optional according to the IEEE 802.3 standard, which means that some links partners may not support it. Siemens offers an advanced Link-Fault-Indication (LFI) feature for the links that do not have a native link partner notification mechanism. With LFI enabled, the device bases the generation of a link integrity signal upon its reception of a link signal. In the example described previously, if switch A fails to receive a link signal from the controller, it will stop generating a link signal. The controller will detect the link failure and failover to the backkup port.

66 Controller Protection Through Link Fault Indication (LFI) RUGGEDCOM ROS Chapter 3 User Guide Device Management

IMPORTANT! If both link partners have the LFI feature, it must not be enabled on both sides of the link. If it is enabled on both sides, the link will never be established, as each link partner will be waiting for the other to transmit a link signal.

The switch can also be configured to flush the MAC address table for the controller port. Frames destined for the controller will be flooded to Switch B where they will be forwarded to the controller (after the controller transmits its first frame).

Section 3.6.2 Viewing the Status of Ethernet Ports

To view the current status of each Ethernet port, navigate to Ethernet Ports » View Port Status . The Port Status table appears.

Figure 21: Port Status Table

This table displays the following information:

Parameter Description

Port Synopsis: 1 to maximum port number The port number as seen on the front plate silkscreen of the switch.

Name Synopsis: Any 15 characters A descriptive name that may be used to identify the device conected on that port.

Link Synopsis: { ----, ----, Down, Up } The port's link status.

Speed Synopsis: { ---, 10M, 100M, 1G, 10G } The port's current speed.

Duplex Synopsis: { ----, Half, Full } The port's current duplex status.

Viewing the Status of Ethernet Ports 67 Chapter 3 RUGGEDCOM ROS Device Management User Guide

Section 3.6.3 Viewing Statistics for All Ethernet Ports

To view statistics collected for all Ethernet ports, navigate to Ethernet Stats » View Ethernet Statistics . The Ethernet Statistics table appears.

Figure 22: Ethernet Statistics Table

This table displays the following information:

Parameter Description

Port Synopsis: 1 to maximum port number The port number as seen on the front plate silkscreen of the switch.

State Synopsis: { ----, ----, Down, Up }

InOctets Synopsis: 0 to 4294967295 The number of octets in received good packets (Unicast+Multicast +Broadcast) and dropped packets.

OutOctets Synopsis: 0 to 4294967295 The number of octets in transmitted good packets.

InPkts Synopsis: 0 to 4294967295 The number of received good packets (Unicast+Multicast+Broadcast) and dropped packets.

OutPkts Synopsis: 0 to 4294967295 The number of transmitted good packets.

ErrorPkts Synopsis: 0 to 4294967295 The number of any type of erroneous packet.

Section 3.6.4 Viewing Statistics for Specific Ethernet Ports

To view statistics collected for specific Ethernet ports, navigate to Ethernet Stats » View Ethernet Port Statistics . The Ethernet Port Statistics table appears.

68 Viewing Statistics for All Ethernet Ports RUGGEDCOM ROS Chapter 3 User Guide Device Management

Figure 23: Ethernet Port Statistics Table

This table displays the following information:

Parameter Description

Port Synopsis: 1 to maximum port number The port number as seen on the front plate silkscreen of the switch.

InOctets Synopsis: 0 to 18446744073709551615 The number of octets in received good packets (Unicast+Multicast +Broadcast) and dropped packets.

OutOctets Synopsis: 0 to 18446744073709551615 The number of octets in transmitted good packets.

InPkts Synopsis: 0 to 18446744073709551615 The number of received good packets (Unicast+Multicast+Broadcast) and dropped packets.

OutPkts Synopsis: 0 to 18446744073709551615 The number of transmitted good packets.

TotalInOctets Synopsis: 0 to 18446744073709551615 The total number of octets of all received packets. This includes data octets of rejected and local packets which are not forwarded to the switching core for transmission. It should reflect all the data octets received on the line.

TotalInPkts Synopsis: 0 to 18446744073709551615 The number of received packets. This includes rejected, dropped local, and packets which are not forwarded to the switching core for transmission. It should reflect all packets received ont the line.

InBroadcasts Synopsis: 0 to 18446744073709551615 The number of good Broadcast packets received.

InMulticasts Synopsis: 0 to 18446744073709551615 The number of good Multicast packets received.

CRCAlignErrors Synopsis: 0 to 4294967295 The number of packets received which meet all the following conditions:

Viewing Statistics for Specific Ethernet Ports 69 Chapter 3 RUGGEDCOM ROS Device Management User Guide

Parameter Description • Packet data length is between 64 and 1536 octets inclusive. • Packet has invalid CRC. • Collision Event has not been detected. • Late Collision Event has not been detected.

OversizePkts Synopsis: 0 to 4294967295 The number of packets received with data length greater than 1536 octets and valid CRC.

Fragments Synopsis: 0 to 4294967295 The number of packets received which meet all the following conditions: • Packet data length is less than 64 octets, or packet without SFD and is less than 64 octets in length. • Collision Event has not been detected. • Late Collision Event has not been detected. • Packet has invalid CRC.

Jabbers Synopsis: 0 to 4294967295 The number of packets which meet all the following conditions: • Packet data length is greater that 1536 octets. • Packet has invalid CRC.

Collisions Synopsis: 0 to 4294967295 The number of received packets for which Collision Event has been detected.

LateCollisions Synopsis: 0 to 4294967295 The number of received packets for which Late Collision Event has been detected.

Pkt64Octets Synopsis: 0 to 4294967295 The number of received and transmitted packets with size of 64 octets. This includes received and transmitted packets as well as dropped and local received packets. This does not include rejected received packets.

Pkt65to127Octets Synopsis: 0 to 4294967295 The number of received and transmitted packets with size of 65 to 127 octets. This includes received and transmitted packets as well as dropped and local received packets. This does not include rejected received packets.

Pkt128to255Octets Synopsis: 0 to 4294967295 The number of received and transmitted packets with size of 128 to 257 octets. This includes received and transmitted packets as well as dropped and local received packets. This does not include rejected received packets.

Pkt256to511Octets Synopsis: 0 to 4294967295 The number of received and transmitted packets with size of 256 to 511 octets. This includes received and transmitted packets as well as dropped and local received packets. This does not include rejected received packets.

Pkt512to1023Octets Synopsis: 0 to 4294967295 The number of received and transmitted packets with size of 512 to 1023 octets. This includes received and transmitted packets as well

70 Viewing Statistics for Specific Ethernet Ports RUGGEDCOM ROS Chapter 3 User Guide Device Management

Parameter Description as dropped and local received packets. This does not include rejected received packets.

Pkt1024to1536Octets Synopsis: 0 to 4294967295 The number of received and transmitted packets with size of 1024 to 1536 octets. This includes received and transmitted packets as well as dropped and local received packets. This does not include rejected received packets.

DropEvents Synopsis: 0 to 4294967295 The number of received packets that are droped due to lack of receive buffers.

OutMulticasts Synopsis: 0 to 18446744073709551615 The number of transmitted Multicast packets. This does not include Broadcast packets.

OutBroadcasts Synopsis: 0 to 18446744073709551615 The number of transmitted Broadcast packets.

UndersizePkts Synopsis: 0 to 4294967295 The number of received packets which meet all the following conditions: • Packet data length is less than 64 octets. • Collision Event has not been detected. • Late Collision Event has not been detected. • Packet has valid CRC.

Section 3.6.5 Clearing Statistics for Specific Ethernet Ports

To clear the statistics collected for one or more Ethernet ports, do the following: 1. Navigate to Ethernet Stats » Clear Ethernet Port Statistics . The Clear Ethernet Port Statistics form appears.

1

2

Figure 24: Clear Ethernet Port Statistics Form (Typical) 1. Port Check Boxes 2. Confirm Button

2. Select one or more Ethernet ports. 3. Click Confirm.

Clearing Statistics for Specific Ethernet Ports 71 Chapter 3 RUGGEDCOM ROS Device Management User Guide

Section 3.6.6 Configuring an Ethernet Port

To configure an Ethernet port, do the following: 1. Navigate to Ethernet Ports » Configure Port Parameters . The Port Parameters table appears.

Figure 25: Port Parameters Table

2. Select an Ethernet port. The Port Parameters form appears.

1

2

3

4

5

6

7

8

9

11 10 12

Figure 26: Port Parameters Form 1. Port Box 2. Name Box 3. Media Box 4. State Box 5. AutoN Box 6. Speed Box 7. Dupx Box 8. FlowCtrl Box 9. LFI Box 10. Alarm Box 11. Apply Button 12. Reload Button

3. Configure the following parameter(s) as required:

Parameter Description

Port Synopsis: 1 to maximum port number

72 Configuring an Ethernet Port RUGGEDCOM ROS Chapter 3 User Guide Device Management

Parameter Description Default: 1 The port number as seen on the front plate silkscreen of the switch.

Name Synopsis: Any 15 characters Default: Port x A descriptive name that may be used to identify the device connected on that port.

Media Synopsis: { 100TX, 10FL, 100FX, 1000X, 1000T, 802.11g, EoVDSL, 100TX Only, 10FL/100SX, 10GX } Default: 100TX The type of the port media.

State Synopsis: { Disabled, Enabled } Default: Enabled Disabling a port will prevent all frames from being sent and received on that port. Also, when disabled link integrity signal is not sent so that the link/activity LED will never be lit. You may want to disable a port for troubleshooting or to secure it from unauthorized connections.

NOTE Disabling a port whose media type is set to 802.11g disables the corresponding wireless module.

AutoN Synopsis: { Off, On } Default: On Enable or disable IEEE 802.3 auto-negotiation. Enabling auto- negotiation results in speed and duplex being negotiated upon link detection; both end devices must be auto-negotiation compliant for the best possible results. 10Mbps and 100Mbps fiber optic media do not support auto-negotiation so these media must be explicitly configured to either half or full duplex. Full duplex operation requires that both ends are configured as such or else severe frame loss will occur during heavy network traffic.

Speed Synopsis: { Auto, 10M, 100M, 1G } Default: Auto Speed (in Megabit-per-second or Gigabit-per-second). If auto- negotiation is enabled, this is the speed capability advertised by the auto-negotiation process. If auto-negotiation is disabled, the port is explicitly forced to this speed mode. AUTO means advertise all supported speed modes.

Dupx Synopsis: { Auto, Half, Full } Default: Auto Duplex mode. If auto-negotiation is enabled, this is the duplex capability advertised by the auto-negotiation process. If auto- negotiation is disabled, the port is explicitly forced to this duplex mode. AUTO means advertise all supported duplex modes.

Flow Control Synopsis: { Off, On } Default: On Flow Control is useful for preventing frame loss during times of severe network traffic. Examples of this include multiple source ports sending to a single destination port or a higher speed port bursting to a lower speed port.

Configuring an Ethernet Port 73 Chapter 3 RUGGEDCOM ROS Device Management User Guide

Parameter Description When the port is half-duplex it is accomplished using 'backpressure' where the switch simulates collisions causing the sending device to retry transmissions according to the Ethernet backoff algorithm. When the port is full-duplex it is accomplished using PAUSE frames which causes the sending device to stop transmitting for a certain period of time.

LFI Synopsis: { Off, On } Default: Off Enabling Link-Fault-Indication (LFI) inhibits transmitting link integrity signal when the receive link has failed. This allows the device at far end to detect link failure under all circumstances.

NOTE This feature must not be enabled at both ends of a fiber link.

Alarm Synopsis: { On, Off } Default: On Disabling link state alarms will prevent alarms and LinkUp and LinkDown SNMP traps from being sent for that port.

NOTE If one end of the link is fixed to a specific speed and duplex type and the peer auto-negotiates, there is a strong possibility that the link will either fail to raise, or raise with the wrong settings on the auto-negotiating side. The auto-negotiating peer will fall back to half-duplex operation, even when the fixed side is full duplex. Full-duplex operation requires that both ends are configured as such or else severe frame loss will occur during heavy network traffic. At lower traffic volumes the link may display few, if any, errors. As the traffic volume rises, the fixed negotiation side will begin to experience dropped packets, while the auto-negotiating side will experience excessive collisions. Ultimately, as traffic load approaches 100%, the link will become entirely unusable. These problems can be avoided by always configuring ports to the appropriate fixed values.

4. Click Apply.

Section 3.6.7 Configuring Port Rate Limiting

To configure port rate limiting, do the following: 1. Navigate to Ethernet Ports » Configure Port Rate Limiting . The Port Rate Limiting table appears.

74 Configuring Port Rate Limiting RUGGEDCOM ROS Chapter 3 User Guide Device Management

Figure 27: Port Rate Limiting Table

2. Select an Ethernet port. The Port Rate Limiting form appears.

1

2

3

4

5 6

Figure 28: Port Rate Limiting Form 1. Port Box 2. Ingress Limit Box 3. Ingress Frames List 4. Egress Limit Box 5. Apply Button 6. Reload Button

3. Configure the following parameter(s) as required:

Parameter Description

Port Synopsis: 1 to maximum port number Default: 1 The port number as seen on the front plate silkscreen of the switch.

Ingress Limit Synopsis: 62 to 256000 Kbps or { Disabled } Default: 1000 Kbps The rate after which received frames (of the type described by the ingress frames parameter) will be discarded by the switch.

Ingress Frames Synopsis: { Broadcast, Bcast&Mcast, Bcast&Mcast&FloodUcast, Bcast&FloodUcast, FloodUcast, All } Default: Broadcast This parameter specifies the types of frames to be rate-limited on this port. It applies only to received frames: • Broadcast - only broadcast frames

Configuring Port Rate Limiting 75 Chapter 3 RUGGEDCOM ROS Device Management User Guide

Parameter Description • Bcast&Mcast - broadcast and multicast frames • Bcast&FloodUcast - broadcast and flooded unicast frames • Bcast&Mcast&FloodUcast - broadcast, multicast and flooded unicast frames • FloodUcast - only flooded unicast frames • All - all (multicast, broadcast and unicast) frames

Egress Limit Synopsis: { Broadcast, Multicast, Mcast&FloodUcast, All }">62 to 256000 Kbps or { Disabled } Default: Disabled The maximum rate at which the switch will transmit (multicast, broadcast and unicast) frames on this port. The switch will discard frames in order to meet this rate if required.

4. Click Apply.

Section 3.6.8 Configuring Port Mirroring

Port mirroring is a troubleshooting tool that copies, or mirrors, all traffic received or transmitted on a designated port to specified mirror port. If a protocol analyzer is attached to the target port, the traffic stream of valid frames on any source port is made available for analysis. Select a target port that has a higher speed than the source port. Mirroring a 100 Mbps port onto a 10 Mbps port may result in an improperly mirrored stream. Frames will be dropped if the full-duplex rate of frames on the source port exceeds the transmission speed of the target port. Since both transmitted and received frames on the source port are mirrored to the target port, frames will be discarded if the sum traffic exceeds the target port’s transmission rate. This problem reaches its extreme in the case where traffic on a 100 Mbps full-duplex port is mirrored onto a 10 Mbps half-duplex port.

NOTE Invalid frames received on the source port will not be mirrored. These include CRC errors, oversize and undersize packets, fragments, jabbers, collisions, late collisions and dropped events.

IMPORTANT! Before configuring port mirroring, note the following limitations: • Traffic will be mirrored onto the target port irrespective of its VLAN membership. It could be the same as or different from the source port's membership • Network management frames (such as RSTP, GVRP etc.) may not be mirrored • Switch management frames generated by the switch (such as Telnet, HTTP, SNMP, etc.) may not be mirrored

To configure port mirroring, do the following: 1. Navigate to Ethernet Ports » Configure Port Mirroring . The Port Mirroring form appears.

76 Configuring Port Mirroring RUGGEDCOM ROS Chapter 3 User Guide Device Management

1

2

3

4

5 6

Figure 29: Port Mirroring Form 1. Port Mirroring Box 2. Source Port Box 3. Target Port Box 4. Apply Button 5. Reload Button

2. Configure the following parameter(s) as required:

Parameter Description

Port Mirroring Synopsis: { Disabled, Enabled } Default: Disabled Enabling port mirroring causes all frames received and transmitted by the source port(s) to be transmitted out of the target port.

Source Port Synopsis: Any combination of numbers valid for this parameter The port(s) being monitored.

Source Direction Synopsis: Egress and Ingress, Egress Only Default: Egress and Ingress Specifies monitoring whether both egress and ingress traffics or only egress traffic of the source port.

Target Port Synopsis: 1 to maximum port number Default: 1 The port where a monitoring device should be connected.

3. Click Apply.

Section 3.6.9 Configuring Link Detection

To configure link detection, do the following: 1. Navigate to Ethernet Ports » Configure Link Detection . The Link Detection form appears.

Configuring Link Detection 77 Chapter 3 RUGGEDCOM ROS Device Management User Guide

1

2

3 4

Figure 30: Link Detection Form 1. Fast Link Detection Box 2. Link Detection Time Box 3. Apply Button 4. Reload Button

2. Configure the following parameter(s) as required:

NOTE When Fast Link Detection is enabled, the system prevents link state change processing from consuming all available CPU resources. However, if Port Guard is not used, it is possible for almost all available CPU time to be consumed by frequent link state changes, which could have a negative impact on overall system responsiveness.

Parameter Description

Fast Link Detection Synopsis: { Off, On, On_withPortGuard } Default: On_withPortGuard This parameter provides protection against faulty end devices generating an improper link integrity signal. When a faulty end device or a mis-matching fiber port is connected to the unit, a large number of continuous link state changes could be reported in a short period of time. These large number of bogus link state changes could render the system unresponsive as most, if not all, of the system resources are used to process the link state changes. This could in turn cause a serious network problem as the unit's RSTP process may not be able to run, thus allowing network loop to form. Three different settings are available for this parameter: • ON_withPortGuard - This is the recommended setting. With this setting, an extended period (~2 minutes) of excessive link state changes reported by a port will prompt Port Guard feature to disable FAST LINK DETECTION on that port and raise an alarm. By disabling FAST LINK DETECTION on the problematic port, excessive link state changes can no longer consume substantial amount of system resources. However if FAST LINK DETECTION is disabled, the port will need a longer time to detect a link failure. This may result in a longer network recovery time of up to 2s. Once Port Guard disables FAST LINK DETECTION of a particular port, user can re-enable FAST LINK DETECTION on the port by clearing the alarm. • ON - In certain special cases where a prolonged excessive link state changes constitute a legitimate link operation, using this setting can prevent Port Guard from disabling FAST LINK DETECTION on the port in question. If excessive link state changes persist for more than 2 minutes, an alarm will be generated to warn user about the observed bouncing link. If the excessive link state changes condition is resolved later on, the alarm will be cleared automatically. Since this option does not disable FAST LINK DETECTION, a persistent bouncing link

78 Configuring Link Detection RUGGEDCOM ROS Chapter 3 User Guide Device Management

Parameter Description could continue affect the system in terms of response time. This setting should be used with caution. • OFF - Turning this parameter OFF will disable FAST LINK DETECTION completely. The switch will need a longer time to detect a link failure. This will result in a longer network recovery time of up to 2s.

Link Detection Time Synopsis: 100 ms to 1000 ms Default: 100 ms The time that the link has to continuously stay up before the "link up" decision is made by the device. (The device performs de-bouncing of Ethernet link detection to avoid multiple responses to an occasional link bouncing event, e.g. when a cable is shaking while being plugged-in or unplugged).

3. Click Apply.

Section 3.6.10 Detecting Cable Faults

Connectivity issues can sometimes be attributed to faults in Ethernet cables. To help detect cable faults, short circuits, open cables or cables that are too long, ROS includes a built-in cable diagnostics utility.

CONTENTS • Section 3.6.10.1, “Viewing Cable Diagnostics Results” • Section 3.6.10.2, “Performing Cable Diagnostics” • Section 3.6.10.3, “Clearing Cable Diagnostics” • Section 3.6.10.4, “Determining the Estimated Distance To Fault (DTF)”

Section 3.6.10.1 Viewing Cable Diagnostics Results

To view the results of previous diagnostic tests, navigate to Ethernet Ports » Configure/View Cable Diagnostics Parameters . The Cable Diagnostics Parameters table appears.

NOTE For information about how to start a diagnostic test, refer to Section 3.6.10.2, “Performing Cable Diagnostics” .

Detecting Cable Faults 79 Chapter 3 RUGGEDCOM ROS Device Management User Guide

Figure 31: Cable Diagnostics Parameters Table

This table displays the following information:

Parameter Description

Port Synopsis: 1 to maximum port number The port number as seen on the front plate silkscreen of the switch.

State Synopsis: { Stopped, Started } Control the start/stop of the cable diagnostics on the selected port. If a port does not support cable diagnostics, State will be reported as N/A.

Runs Synopsis: 0 to 65535 The total number of times cable diagnostics to be performed on the selected port. If this number is set to 0, cable diagnostics will be performed forever on the selected port.

Calib. Synopsis: -100.0 to 100.0 m This calibration value can be used to adjust or calibrate the estimated distance to fault. User can take following steps to calibrate the cable diagnostics estimated distance to fault: • Pick a particular port which calibration is needed • Connect an Ethernet cable with a known length (e.g. 50m) to the port • DO NOT connect the other end of the cable to any link partner • Run cable diagnostics a few times on the port. OPEN fault should be detected • Find the average distance to the OPEN fault recorded in the log and compare it to the known length of the cable. The difference can be used as the calibration value • Enter the calibration value and run cable diagnostics a few more times • The distance to OPEN fault should now be at similar distance as the cable length • Distance to fault for the selected port is now calibrated

Good Synopsis: 0 to 65535 The number of times GOOD TERMINATION (no fault) is detected on the cable pairs of the selected port.

Open Synopsis: 0 to 65535

80 Viewing Cable Diagnostics Results RUGGEDCOM ROS Chapter 3 User Guide Device Management

Parameter Description The number of times OPEN is detected on the cable pairs of the selected port.

Short Synopsis: 0 to 65535 The number of times SHORT is detected on the cable pairs of the selected port.

Imped Synopsis: 0 to 65535 The number of times IMPEDANCE MISMATCH is detected on the cable pairs of the selected port.

Pass /Fail /Total Synopsis: Any 19 characters This field summarizes the results of the cable diagnostics performed so far. Pass - number of times cable diagnostics successfully completed on the selected port. Fail - number of times cable diagnostics failed to complete on the selected port. Total - total number of times cable diagnostics have been attempted on the selected port.

NOTE For each successful diagnostic test, the values for Good, Open, Short or Imped will increment based on the number of cable pairs connected to the port. For a 100Base-T port, which has two cable pairs, the number will increase by two. For a 1000Base-T port, which has four cable pairs, the number will increase by four.

NOTE When a cable fault is detected, an estimated distance-to-fault is calculated and recorded in the system log. The log lists the cable pair, the fault that was detected, and the distance-to-fault value. For more information about the system log, refer to Section 3.5.1, “Viewing Local Logs” .

Section 3.6.10.2 Performing Cable Diagnostics

To perform a cable diagnostic test on one or more Ethernet ports, do the following: 1. Connect a CAT-5 (or better quality) Ethernet cable to the selected Ethernet port.

IMPORTANT! Both the selected Ethernet port and its partner port can be configured to run in Enabled mode with auto-negotiation, or in Disabled mode. Other modes are not recommended, as they may interfere with the cable diagnostics procedure.

2. Connect the other end of the cable to a similar network port. For example, connect a 100Base-T port to a 100Base-T port, or a 1000Base-T port to a 1000Base-T port. 3. In ROS, navigate to Ethernet Ports » Configure/View Cable Diagnostics Parameters . The Cable Diagnostics Parameters table appears.

Performing Cable Diagnostics 81 Chapter 3 RUGGEDCOM ROS Device Management User Guide

Figure 32: Cable Diagnostics Parameters Table

4. Select an Ethernet port. The Cable Diagnostics Parameters form appears.

1

2

3

4

5

6

7

8

9

10 11

Figure 33: Cable Diagnostics Parameters Form 1. Port Box 2. State Options 3. Runs Box 4. Calib. Box 5. Good Box 6. Open Box 7. Short Box 8. Imped Box 9. Pass / Fail /Total Box 10. Apply Button 11. Reload Button

5. Under Runs, enter the number of consecutive diagnostic tests to perform. A value of 0 indicates the test will run continuously until stopped by the user. 6. Under Calib., enter the estimated Distance To Fault (DTF) value. For information about how to determine the DTF value, refer to Section 3.6.10.4, “Determining the Estimated Distance To Fault (DTF)” . 7. Select Started.

IMPORTANT! A diagnostic test can be stopped by selecting Stopped and clicking Apply. However, if the test is stopped in the middle of a diagnostic run, the test will run to completion.

82 Performing Cable Diagnostics RUGGEDCOM ROS Chapter 3 User Guide Device Management

8. Click Apply. The state of the Ethernet port will automatically change to Stopped when the test is complete. For information about how to monitor the test and view the results, refer to Section 3.6.10.1, “Viewing Cable Diagnostics Results” .

Section 3.6.10.3 Clearing Cable Diagnostics

To clear the cable diagnostic results, do the following: 1. Navigate to Ethernet Ports » Clear Cable Diagnostics Statistics . The Clear Cable Diagnostics Statistics form appears.

1

2

Figure 34: Clear Cable Diagnostics Statistics Form 1. Port Check Boxes 2. Apply Button

2. Select one or more Ethernet ports. 3. Click Apply.

Section 3.6.10.4 Determining the Estimated Distance To Fault (DTF)

To determine the estimate Distance To Fault (DTF), do the following: 1. Connect a CAT-5 (or better quality) Ethernet cable with a known length to the device. Do not connect the other end of the cable to another port. 2. Configure the cable diagnostic utility to run a few times on the selected Ethernet port and start the test. For more information, refer to Section 3.6.10.2, “Performing Cable Diagnostics” . Open faults should be detected and recorded in the system log. 3. Review the errors recorded in the system log and determine the average distance of the open faults. For more information about the system log, refer to Section 3.5.1, “Viewing Local Logs” . 4. Subtract the average distance from the cable length to determine the calibration value. 5. Configure the cable diagnostic utility to run a few times with the new calibration value. The distance to the open fault should now be the same as the actual length of the cable. The Distance To Fault (DTF) is now calibrated for the selected Ethernet port.

Clearing Cable Diagnostics 83 Chapter 3 RUGGEDCOM ROS Device Management User Guide

Section 3.6.11 Resetting Ethernet Ports

At times, it may be necessary to reset a specific Ethernet port, such as when the link partner has latched into an inappropriate state. This is also useful for forcing a re-negotiation of the speed and duplex modes. To reset a specific Ethernet port(s), do the following: 1. Navigate to Ethernet Ports » Reset Port(s) . The Reset Port(s) form appears.

1

2

Figure 35: Reset Port(s) Form 1. Ports 2. Apply Button

2. Select one or more Ethernet ports to reset. 3. Click Apply. The selected Ethernet ports are reset.

Section 3.7 Managing IP Interfaces

RUGGEDCOM ROS allows one IP interface to be configured for each subnet (or VLAN), up to a maximum of 255 interfaces. One of the interfaces must also be configured to be a management interface for certain IP services, such as DHCP relay agent. Each IP interface must be assigned an IP address. In the case of the management interface, the IP address type can be either static, DHCP, BOOTP or dynamic. For all other interfaces, the IP address must be static.

CAUTION! Configuration hazard – risk of communication disruption. Changing the ID for the management VLAN will break any active Raw Socket TCP connections. If this occurs, reset all serial ports.

CONTENTS • Section 3.7.1, “Viewing a List of IP Interfaces” • Section 3.7.2, “Adding an IP Interface”

84 Resetting Ethernet Ports RUGGEDCOM ROS Chapter 3 User Guide Device Management

• Section 3.7.3, “Deleting an IP Interface”

Section 3.7.1 Viewing a List of IP Interfaces

To view a list of IP interfaces configured on the device, navigate to Administration » Configure IP Interfaces » Configure IP Interfaces . The IP Interfaces table appears.

Figure 36: IP Interfaces Table

If IP interfaces have not been configured, add IP interfaces as needed. For more information, refer to Section 3.7.2, “Adding an IP Interface” .

Section 3.7.2 Adding an IP Interface

To add an IP interface, do the following: 1. Navigate to Administration » Configure IP Interfaces . The IP Interfaces table appears.

1

Figure 37: IP Interfaces Table 1. InsertRecord

2. Click InsertRecord. The Switch IP Interfaces form appears.

Viewing a List of IP Interfaces 85 Chapter 3 RUGGEDCOM ROS Device Management User Guide

1

2

3

4

5

6

7 9

8

Figure 38: IP Interfaces Form 1. Type Options 2. ID Box 3. Mgmt Options 4. IP Address Type Box 5. IP Address Box 6. Subnet Box 7. Apply Button 8. Delete Button 9. Reload Button

3. Configure the following parameter(s) as required:

NOTE The IP address and mask configured for the management VLAN are not changed when resetting all configuration parameters to defaults and will be assigned a default VLAN ID of 1. Changes to the IP address take effect immediately. All IP connections in place at the time of an IP address change will be lost.

Parameter Description

Type Synopsis: { VLAN } Default: VLAN Specifies the type of the interface for which this IP interface is created.

ID Synopsis: 1 to 4094 Default: 1 Specifies the ID of the interface for which this IP interface is created. If the interface type is VLAN, this represents the VLAN ID.

Mgmt Synopsis: { No, Yes } Default: No Specifies whether the IP interface is the device management interface.

IP Address Type Synopsis: { Static, Dynamic, DHCP, BOOTP } Default: Static Specifies whether the IP address is static or is dynamically assigned via DHCP or BOOTP>. The Dynamic option automatically switches between BOOTP and DHCP until it receives a response from the relevant server. The Static option must be used for non- management interfaces.

IP Address Synopsis: ###.###.###.### where ### ranges from 0 to 255 Default: 192.168.0.1

86 Adding an IP Interface RUGGEDCOM ROS Chapter 3 User Guide Device Management

Parameter Description Specifies the IP address of this device. An IP address is a 32-bit number that is notated by using four numbers from 0 through 255, separated by periods. Only a unicast IP address is allowed, which ranges from 1.0.0.0 to 233.255.255.255.

Subnet Synopsis: ###.###.###.### where ### ranges from 0 to 255 Default: 255.255.255.0 Specifies the IP subnet mask of this device. An IP subnet mask is a 32-bit number that is notated by using four numbers from 0 through 255, separated by periods. Typically, subnet mask numbers use either 0 or 255 as values (e.g. 255.255.255.0) but other numbers can appear.

IMPORTANT! Each IP interface must have a unique network address.

4. Click Apply.

Section 3.7.3 Deleting an IP Interface

To delete an IP interface configured on the device, do the following: 1. Navigate to Administration » Configure IP Interfaces . The IP Interfaces table appears.

Figure 39: IP Interfaces Table

2. Select the IP interface from the table. The IP Interfaces form appears.

Deleting an IP Interface 87 Chapter 3 RUGGEDCOM ROS Device Management User Guide

1

2

3

4

5

6

7 9

8

Figure 40: IP Interfaces Form 1. IP Address Type Box 2. IP Address Box 3. Subnet Box 4. Apply Button 5. Delete Button 6. Reload Button

3. Click Delete.

Section 3.8 Managing IP Gateways

RUGGEDCOM ROS allows up to ten IP gateways to be configured. When both the Destination and Subnet parameters are blank, the gateway is considered to be a default gateway.

NOTE The default gateway configuration will not be changed when resetting all configuration parameters to their factory defaults.

CONTENTS • Section 3.8.1, “Viewing a List of IP Gateways” • Section 3.8.2, “Adding an IP Gateway” • Section 3.8.3, “Deleting an IP Gateway”

Section 3.8.1 Viewing a List of IP Gateways

To view a list of IP gateways configured on the device, navigate to Administration » Configure IP Gateways . The IP Gateways table appears.

88 Managing IP Gateways RUGGEDCOM ROS Chapter 3 User Guide Device Management

Figure 41: IP Gateways Table

If IP gateways have not been configured, add IP gateways as needed. For more information, refer to Section 3.8.2, “Adding an IP Gateway” .

Section 3.8.2 Adding an IP Gateway

To add an IP gateway, do the following: 1. Navigate to Administration » Configure IP Gateways . The IP Gateways table appears.

1

Figure 42: IP Gateways Table 1. InsertRecord

2. Click InsertRecord. The IP Gateways form appears.

Adding an IP Gateway 89 Chapter 3 RUGGEDCOM ROS Device Management User Guide

1

2

3

4 6

5

Figure 43: IP Gateways 1. Destination Box 2. Subnet Box 3. Gateway Box 4. Apply Button 5. Delete Button 6. Reload Button

3. Configure the following parameter(s) as required:

Parameter Description

Destination Synopsis: ###.###.###.### where ### ranges from 0 to 255 Specifies the IP address of destination network or host. For default gateway, both the destination and subnet are 0.

Subnet Synopsis: ###.###.###.### where ### ranges from 0 to 255 Specifies the destination IP subnet mask. For default gateway, both the destination and subnet are 0.

Gateway Synopsis: ###.###.###.### where ### ranges from 0 to 255 Specifies the gateway to be used to reach the destination.

4. Click Apply.

Section 3.8.3 Deleting an IP Gateway

To delete an IP gateway configured on the device, do the following: 1. Navigate to Administration » Configure IP Gateways . The IP Gateways table appears.

Figure 44: IP Gateways Table

90 Deleting an IP Gateway RUGGEDCOM ROS Chapter 3 User Guide Device Management

2. Select the IP gateway from the table. The IP Gateways form appears.

1

2

3

4 6

5

Figure 45: IP Gateways Form 1. Destination Box 2. Subnet Box 3. Gateway Box 4. Apply Button 5. Delete Button 6. Reload Button

3. Click Delete.

Section 3.9 Configuring IP Services

To configure the IP services provided by the device, do the following: 1. Navigate to Administration » Configure IP Services . The IP Services form appears.

Configuring IP Services 91 Chapter 3 RUGGEDCOM ROS Device Management User Guide

1

2

3

4

5

6

7

8

9

10

11

12 13

Figure 46: IP Services Form 1. Inactivity Timeout Box 2. Telnet Sessions Allowed Box 3. Web Server Users Allowed Box 4. TFTP Server Box 5. Modbus Address Box 6. SSH Sessions Allowed Box 7. RSH Server Options 8. IP Forward Options 9. Max Failed Attempts Box 10. Failed Attempts Window Box 11. Lockout Time Box 12. Apply Button 13. Reload Button

2. Configure the following parameter(s) as required:

Parameter Description

Inactivity Timeout Synopsis: 1 to 60 or { Disabled } Default: 5 min Specifies when the console will timeout and display the login screen if there is no user activity. A value of zero disables timeouts. For Web Server users maximum timeout value is limited to 30 minutes.

Telnet Sessions Allowed Synopsis: 1 to 4 or { Disabled } Default: Disabled Limits the number of Telnet sessions. A value of zero prevents any Telnet access.

Web Server Users Allowed Synopsis: 1 to 4 or { Disabled } Default: 4 Limits the number of simultaneous web server users.

TFTP Server Synopsis: { Disabled, Get Only, Enabled } Default: Disabled As TFTP is a very insecure protocol, this parameter allows user to limit or disable TFTP Server access.. DISABLED - disables read and write access to TFTP Server GET ONLY - only allows reading of files via TFTP Server ENABLED - allows reading and writing of files via TFTP Server

ModBus Address Synopsis: 1 to 255 or { Disabled } Default: Disabled

92 Configuring IP Services RUGGEDCOM ROS Chapter 3 User Guide Device Management

Parameter Description Determines the Modbus address to be used for Management through Modbus.

SSH Sessions Allowed (Controlled Version Only) Synopsis: 1 to 4 Default: 4 Limits the number of SSH sessions.

RSH Server Synopsis: { Disabled, Enabled } Default: Disabled (controlled version) or Enabled (non- controlled version) Disables/enables Remote Shell access.

IP Forward Synopsis: { Disabled, Enabled } Controls the ability of IP Forwarding between VLANs in Serial Server or IP segments.

NOTE When upgrading to ROS v4.3, the default will be set to { Enabled }.

Max Failed Attempts Synopsis: 1 to 20 Default: 10 Maximum number of consecutive failed access attempts on service within Failed Attempts Window before blocking the service.

Failed Attempts Window Synopsis: 1 to 30 min Default: 5 min The time in minutes (min) in which the maximum number of failed login attempts must be exceeded before a service is blocked. The counter of failed attempts resets to 0 when the timer expires.

Lockout Time Synopsis: 1 to 120 min Default: 60 min The time in minutes (min) the service remains locked out after the maximum number of failed access attempts has been reached.

3. Click Apply.

Section 3.10 Managing Remote Monitoring

Remote Monitoring (RMON) is used to collect and view historical statistics related to the performance and operation of Ethernet ports. It can also record a log entry and/or generate an SNMP trap when the rate of occurrence of a specified event is exceeded.

CONTENTS • Section 3.10.1, “Managing RMON History Controls” • Section 3.10.2, “Managing RMON Alarms”

Managing Remote Monitoring 93 Chapter 3 RUGGEDCOM ROS Device Management User Guide

• Section 3.10.3, “Managing RMON Events”

Section 3.10.1 Managing RMON History Controls

The history controls for Remote Monitoring take samples of the RMON-MIB history statistics of an Ethernet port at regular intervals.

CONTENTS • Section 3.10.1.1, “Viewing a List of RMON History Controls” • Section 3.10.1.2, “Adding an RMON History Control” • Section 3.10.1.3, “Deleting an RMON History Control”

Section 3.10.1.1 Viewing a List of RMON History Controls

To view a list of RMON history controls, navigate to Ethernet Stats » Configure RMON History Controls . The RMON History Controls table appears.

Figure 47: RMON History Controls Table

If history controls have not been configured, add controls as needed. For more information, refer to Section 3.10.1.2, “Adding an RMON History Control” .

Section 3.10.1.2 Adding an RMON History Control

To add an RMON history control, do the following: 1. Navigate to Ethernet Stats » Configure RMON History Controls . The RMON History Controls table appears.

94 Managing RMON History Controls RUGGEDCOM ROS Chapter 3 User Guide Device Management

1

Figure 48: RMON History Controls Table 1. InsertRecord

2. Click InsertRecord. The RMON History Controls form appears.

1

2

3

4

5

6

7 10

8 9

Figure 49: RMON History Controls Form 1. Index Box 2. Port Box 3. Requested Buckets Box 4. Granted Buckets Box 5. Interval Box 6. Owner Box 7. Apply Button 8. Delete Button 9. Reload Button

3. Configure the following parameter(s) as required:

Parameter Description

Index Synopsis: 1 to 65535 Default: 1 The index of this RMON History Contol record.

Port Synopsis: 1 to maximum port number Default: 1 The port number as seen on the front plate silkscreen of the switch.

Requested Buckets Synopsis: 1 to 4000 Default: 50 The maximum number of buckets requested for this RMON collection history group of statistics. The range is 1 to 4000. The default is 50.

Adding an RMON History Control 95 Chapter 3 RUGGEDCOM ROS Device Management User Guide

Parameter Description

Granted Buckets Synopsis: 0 to 65535 The number of buckets granted for this RMON collection history. This field is not editable.

Interval Synopsis: 1 to 3600 Default: 1800 The number of seconds in over which the data is sampled for each bucket. The range is 1 to 3600. The default is 1800.

Owner Synopsis: Any 127 characters Default: Monitor The owner of this record. It is suggested to start this string withword 'monitor'.

4. Click Apply.

Section 3.10.1.3 Deleting an RMON History Control

To delete an RMON history control, do the following: 1. Navigate to Ethernet Stats » Configure RMON History Controls . The RMON History Controls table appears.

Figure 50: RMON History Controls Table

2. Select the history control from the table. The RMON History Controls form appears.

96 Deleting an RMON History Control RUGGEDCOM ROS Chapter 3 User Guide Device Management

1

2

3

4

5

6

7 10

8 9

Figure 51: RMON History Controls Form 1. Index Box 2. Port Box 3. Requested Buckets Box 4. Granted Buckets Box 5. Interval Box 6. Owner Box 7. Apply Button 8. Delete Button 9. Reload Button

3. Click Delete.

Section 3.10.2 Managing RMON Alarms

When Remote Monitoring (RMON) alarms are configured, RUGGEDCOM ROS examines the state of a specific statistical variable. Remote Monitoring (RMON) alarms define upper and lower thresholds for legal values of specific statistical variables in a given interval. This allows RUGGEDCOM ROS to detect events as they occur more quickly than a specified maximum rate or less quckly than a minimum rate. When the rate of change for a statistics value exceeds its limits, an internal INFO alarm is always generated. For information about viewing alarms, refer to Section 4.6.2, “Viewing and Clearing Latched Alarms” . Additionally, a statistic threshold crossing can result in further activity. An RMON alarm can be configured to point to a particular RMON event, which can generate an SNMP trap, an entry in the event log, or both. The RMON event can also direct alarms towards different users defined for SNMP. The alarm can point to a different event for each of the thresholds. Therefore, combinations such as trap on rising threshold or trap on rising threshold, log and trap on falling threshold are possible. Each RMON alarm may be configured such that its first instance occurs only for rising, falling, or all thresholds that exceed their limits. The ability to configure upper and lower thresholds on the value of a measured statistic provides for the ability to add hysteresis to the alarm generation process. If the value of the measured statistic over time is compared to a single threshold, alarms will be generated each time the statistic crosses the threshold. If the statistic’s value fluctuates around the threshold, an alarm can be generated every measurement period. Programming different upper and lower thresholds eliminates spurious alarms. The statistic value must travel between the thresholds before alarms can be generated. The following illustrates the very different patterns of alarm generation resulting from a statistic sample and the same sample with hysteresis applied.

Managing RMON Alarms 97 Chapter 3 RUGGEDCOM ROS Device Management User Guide

Figure 52: The Alarm Process

There are two methods to evaluate a statistic in order to determine when to generate an event: delta and absolute. For most statistics, such as line errors, it is appropriate to generate an alarm when a rate is exceeded. The alarm defaults to the delta measurement method, which examines changes in a statistic at the end of each measurement period. It may be desirable to alarm when the total, or absolute, number of events crosses a threshold. In this case, set the measurement period type to absolute.

CONTENTS • Section 3.10.2.1, “Viewing a List of RMON Alarms” • Section 3.10.2.2, “Adding an RMON Alarm” • Section 3.10.2.3, “Deleting an RMON Alarm”

Section 3.10.2.1 Viewing a List of RMON Alarms

To view a list of RMON alarms, navigate to Ethernet Stats » Configure RMON Alarms . The RMON Alarms table appears.

Figure 53: RMON Alarms Table

If alarms have not been configured, add alarms as needed. For more information, refer to Section 3.10.2.2, “Adding an RMON Alarm” .

98 Viewing a List of RMON Alarms RUGGEDCOM ROS Chapter 3 User Guide Device Management

Section 3.10.2.2 Adding an RMON Alarm

To add an RMON alarm, do the following: 1. Navigate to Ethernet Stats » Configure RMON Alarms . The RMON Alarms table appears.

1

Figure 54: RMON Alarms Table 1. InsertRecord

2. Click InsertRecord. The RMON Alarms form appears.

1

2

3

4

5

6

7

8

9

10

11

12 14

13

Figure 55: RMON Alarms Form 1. Index Box 2. Variable Box 3. Rising Thr Box 4. Falling Thr Box 5. Value Box 6. Type Options 7. Interval Box 8. Startup Alarm List 9. Rising Event Box 10. Falling Event Box 11. Owner Box 12. Apply Button 13. Delete Button 14. Reload Button

3. Configure the following parameter(s) as required:

Adding an RMON Alarm 99 Chapter 3 RUGGEDCOM ROS Device Management User Guide

Parameter Description

Index Synopsis: 1 to 65535 Default: 1 The index of this RMON Alarm record.

Variable Synopsis: SNMP Object Identifier - up to 39 characters The SNMP object identifier (OID) of the particular variable to be sampled. Only variables that resolve to an ASN.1 primitive type INTEGER (INTEGER, Integer32,Counter32, Counter64, Gauge, or TimeTicks) may be sampled. A list of objects can be printed using shell command 'rmon'. The OID format: objectName.index1.index2... where index format depends on index object type.

Rising Thr Synopsis: -2147483647 to 2147483647 Default: 0 A threshold for the sampled variable. When the current sampled variable value is greater than or equal to this threshold, and the value at the last sampling interval was less than this threshold, a single event will be generated. A single event will also be generated if the first sample after this record is created is greater than or equal to this threshold and the associated startup alarm ils equal to 'rising'.After rising alarm is generated, another such event will not be generated until the sampled value falls below this threshold and reaches the value of FallingThreshold.

Falling Thr Synopsis: -2147483647 to 2147483647 Default: 0 A threshold for the sampled variable. When the current sampled variable value is less than or equal to this threshold, and the value at the last sampling interval was greater than this threshold, a single event will be generated. A single event will also be generated if the first sample after this record is created is less than or equal to this threshold and the associated startup alarm ils equal to 'falling'.After falling alarm is generated, another such event will not be generated until the sampled value rises above this threshold and reaches the value of RisingThreshold.

Value Synopsis: -2147483647 to 2147483647 The value of monitoring object during the last sampling period. The presentation of value depends of sample type ('absolute' or 'delta').

Type Synopsis: { absolute, delta } Default: delta The method of sampling the selected variable and calculating the value to be compared against the thresholds. The value of sample type can be 'absolute' or 'delta'.

Interval Synopsis: 0 to 2147483647 Default: 60 The number of seconds in over which the data is sampled and compared with the rising and falling thresholds.

Startup Alarm Synopsis: { rising, falling, risingOrFalling } Default: risingOrFalling The alarm that may be sent when this record is first created if condition for raising alarm is met. The value of startup alarm can be 'rising', 'falling' or 'risingOrFalling'.

Rising Event Synopsis: 0 to 65535 Default: 0

100 Adding an RMON Alarm RUGGEDCOM ROS Chapter 3 User Guide Device Management

Parameter Description The index of the event that is used when a falling threshold is crossed. If there is no corresponding entryl in the Event Table, then no association exists. In particular, if this value is zero, no associated event will be generated.

Falling Event Synopsis: 0 to 65535 Default: 0 The index of the event that is used when a rising threshold is crossed. If there is no corresponding entryl in the Event Table, then no association exists. In particular, if this value is zero, no associated event will be generated.

Owner Synopsis: Any 127 characters Default: Monitor The owner of this record. It is suggested to start this string withword 'monitor'.

4. Click Apply.

Section 3.10.2.3 Deleting an RMON Alarm

To delete an RMON alarm, do the following: 1. Navigate to Ethernet Stats » Configure RMON Alarms . The RMON Alarms table appears.

Figure 56: RMON Alarms Table

2. Select the alarm from the table. The RMON Alarms form appears.

Deleting an RMON Alarm 101 Chapter 3 RUGGEDCOM ROS Device Management User Guide

1

2

3

4

5

6

7

8

9

10

11

12 14

13

Figure 57: RMON Alarms Form 1. Index Box 2. Variable Box 3. Rising Thr Box 4. Falling Thr Box 5. Value Box 6. Type Options 7. Interval Box 8. Startup Alarm List 9. Rising Event Box 10. Falling Event Box 11. Owner Box 12. Apply Button 13. Delete Button 14. Reload Button

3. Click Delete.

Section 3.10.3 Managing RMON Events

Remote Monitoring (RMON) events define behavior profiles used in event logging. These profiles are used by RMON alarms to send traps and log events. Each alarm may specify that a log entry be created on its behalf whenever the event occurs. Each entry may also specify that a notification should occur by way of SNMP trap messages. In this case, the user for the trap message is specified as the Community. Two traps are defined: risingAlarm and fallingAlarm.

CONTENTS • Section 3.10.3.1, “Viewing a List of RMON Events” • Section 3.10.3.2, “Adding an RMON Event”

102 Managing RMON Events RUGGEDCOM ROS Chapter 3 User Guide Device Management

• Section 3.10.3.3, “Deleting an RMON Event”

Section 3.10.3.1 Viewing a List of RMON Events

To view a list of RMON events, navigate to Ethernet Stats » Configure RMON Events . The RMON Events table appears.

Figure 58: RMON Events Table

If events have not been configured, add events as needed. For more information, refer to Section 3.10.3.2, “Adding an RMON Event” .

Section 3.10.3.2 Adding an RMON Event

To add an RMON alarm, do the following: 1. Navigate to Ethernet Stats » Configure RMON Events . The RMON Events table appears.

1

Figure 59: RMON Events Table 1. InsertRecord

2. Click InsertRecord. The RMON Events form appears.

Viewing a List of RMON Events 103 Chapter 3 RUGGEDCOM ROS Device Management User Guide

1

2

3

4

5

6

7 9

8

Figure 60: RMON Events Form 1. Index Box 2. Type List 3. Community Box 4. Last Time Sent Box 5. Description Box 6. Owner Box 7. Apply Button 8. Delete Button 9. View Button 10. Reload Button

3. Configure the following parameter(s) as required:

Parameter Description

Index Synopsis: 1 to 65535 Default: 3 The index of this RMON Event record.

Type Synopsis: { none, log, snmpTrap, logAndTrap } Default: logAndTrap The type of notification that the probe will make about this event. In the case of 'log', an entry is made in the RMON Log table for each event. In the case of snmp_trap, an SNMP trap is sent to one or more management stations.

Community Synopsis: Any 31 characters Default: public If the SNMP trap is to be sent, it will be sent to the SNMP community specified by this string.

Last Time Sent Synopsis: DDDD days, HH:MM:SS The time from last reboot at the time this event entry last generated an event. If this entry has not generated any events, this value will be 0.

Description Synopsis: Any 127 characters Default: EV2-Rise A comment describing this event.

Owner Synopsis: Any 127 characters Default: Monitor The owner of this event record. It is suggested to start this string withword 'monitor'.

4. Click Apply.

104 Adding an RMON Event RUGGEDCOM ROS Chapter 3 User Guide Device Management

Section 3.10.3.3 Deleting an RMON Event

To delete an RMON event, do the following: 1. Navigate to Ethernet Stats » Configure RMON Events . The RMON Events table appears.

Figure 61: RMON Events Table

2. Select the event from the table. The RMON Events form appears.

1

2

3

4

5

6

7 9

8

Figure 62: RMON Events Form 1. Index Box 2. Type List 3. Community Box 4. Last Time Sent Box 5. Description Box 6. Owner Box 7. Apply Button 8. Delete Button 9. View Button 10. Reload Button

3. Click Delete.

Section 3.11 Upgrading/Downgrading Firmware

The following section describes how to upgrade and downgrade the firmware.

CONTENTS • Section 3.11.1, “Upgrading Firmware”

Deleting an RMON Event 105 Chapter 3 RUGGEDCOM ROS Device Management User Guide

• Section 3.11.2, “Downgrading Firmware”

Section 3.11.1 Upgrading Firmware

Upgrading RUGGEDCOM ROS firmware, including the main, bootloader and FPGA firmware, may be necessary to take advantage of new features or bug fixes. Binary firmware images are available from Siemens. Visit www.siemens.com/ruggedcom to determine which versions/updates are available or contact Siemens Customer Support. Binary firmware images transferred to the device are stored in non-volatile Flash memory and require a device reset in order to take effect.

IMPORTANT! Non-Controlled (NC) versions of RUGGEDCOM ROS can not be upgraded to Controlled firmware versions. However, Controlled firmware versions can be upgraded to an NC firmware version.

NOTE The IP address set for the device will not be changed following a firmware upgrade.

To upgrade the RUGGEDCOM ROS firmware, do the following: 1. Upload a different version of the binary firmware image to the device. For more information, refer to Section 3.4, “Uploading/Downloading Files” . 2. Reset the device to complete the installation. For more information, refer to Section 3.12, “Resetting the Device” . 3. Access the CLI shell and verify the new software version has been installed by typing version. The currently installed versions of the main and boot firmware are displayed.

>version Current ROS-CF52 Boot Software v2.20.0 (Jan 29 2013 13:25) Current ROS-CF52 Main Software v4.0 (Feb 2 2013 09:33)

Section 3.11.2 Downgrading Firmware

Downgrading the RUGGEDCOM ROS firmware is generally not recommended, as it may have unpredictable effects. However, if a downgrade is required, do the following:

IMPORTANT! Before downgrading the firmware, make sure the hardware and FPGA code types installed in the device are supported by the older firmware version. Refer to the Release Notes for the older firmware version to confirm.

IMPORTANT! Non-Controlled (NC) versions of RUGGEDCOM ROS can not be downgraded to Controlled firmware versions. However, Controlled firmware versions can be downgraded to an NC firmware version.

106 Upgrading Firmware RUGGEDCOM ROS Chapter 3 User Guide Device Management

CAUTION! Do not downgrade the RUGGEDCOM ROS boot version.

1. Disconnect the device from the network. 2. Log in to the device as an admin user. For more information, refer to Section 2.2, “Logging In” . 3. Make a local copy of the current configuration file. For more information, refer to Section 3.4, “Uploading/ Downloading Files” .

IMPORTANT! Never downgrade the RUGGEDCOM ROS software version beyond RUGGEDCOM ROS v4.3 when encryption is enabled. Make sure the device has been restored to factory defaults before downgrading.

4. Restore the device to its factory defaults. For more information, refer to Section 3.3, “Restoring Factory Defaults” . 5. Upload and apply the older firmware version and its associated FPGA files using the same methods used to install newer firmware versions. For more information , refer to Section 3.11.1, “Upgrading Firmware” . 6. Press Ctrl-S to access the CLI. 7. Clear all logs by typing:

clearlogs 8. Clear all alarms by typing:

clearalarms

IMPORTANT! After downgrading the firmware and FPGA files, be aware that some settings from the previous configuration may be lost or reverted back to the factory defaults (including user passwords if downgrading from a security related version), as those particular tables or fields may not exist in the older firmware version. Because of this, the unit must be configured after the downgrade.

9. Configure the device as required.

Section 3.12 Resetting the Device

To reset the device, do the following: 1. Navigate to Diagnostics » Reset Device . The Reset Device form appears.

Resetting the Device 107 Chapter 3 RUGGEDCOM ROS Device Management User Guide

1

Figure 63: Reset Device Form 1. Confirm Button

2. Click Confirm.

Section 3.13 Decommissioning the Device

Before taking the device out of service, either permanently or for maintenance by a third-party, make sure the device has been fully decommissioned. This includes removing any sensitive, proprietary information. To decommission the device, do the following: 1. Disconnect all network cables from the device. 2. Connect to the device via the RS-232 serial console port. For more information, refer to Section 2.1.1, “Connecting Directly” . 3. Restore all factory default settings for the device. For more information, refer to Section 3.3, “Restoring Factory Defaults” . 4. Access the CLI. For more information, refer to Section 2.6, “Using the Command Line Interface” . 5. Upload a blank version of the banner.txt file to the device to replace the existing file. For more information about uploading a file, refer to Section 3.4, “Uploading/Downloading Files” . 6. Confirm the upload was successful by typing:

type banner.txt 7. Clear the system and crash logs by typing:

clearlog 8. Generate a random SSL certificate by typing:

sslkeygen This may take several minutes to complete. To verify the certificate has been generated, type:

type syslog.txt When the phrase Generated ssl.crt was saved appears in the log, the SSL certificate has been generated. 9. Generate random SSH keys by typing:

sshkeygen This may take several minutes to complete. To verify the keys have been generated, type:

108 Decommissioning the Device RUGGEDCOM ROS Chapter 3 User Guide Device Management

type syslog.txt When the phrase Generated ssh.keys was saved appears in the log, the SSH keys have been generated. 10. De-fragment and erase all free flash memory by typing:

flashfile defrag This may take several minutes to complete.

Decommissioning the Device 109 RUGGEDCOM ROS Chapter 3 User Guide Device Management

Decommissioning the Device 110 RUGGEDCOM ROS Chapter 4 User Guide System Administration

System Administration

This chapter describes how to perform various administrative tasks related to device identification, user permissions, alarm configuration, certificates and keys, and more.

CONTENTS • Section 4.1, “Configuring the System Information” • Section 4.2, “Customizing the Login Screen” • Section 4.3, “Configuring Passwords” • Section 4.4, “Clearing Private Data” • Section 4.5, “Enabling/Disabling the Web Interface” • Section 4.6, “Managing Alarms” • Section 4.7, “Managing the Configuration File” • Section 4.8, “Managing an Authentication Server”

Section 4.1 Configuring the System Information

To configure basic information that can be used to identify the device, its location, and/or its owner, do the following: 1. Navigate to Administration » Configure System Identification . The System Identification form appears.

1

2

3

4 5

Figure 64: System Identification Form 1. System Name Box 2. Location Box 3. Contact Box 4. Apply Button 5. Reload Button

2. Configure the following parameter(s) as required:

Parameter Description

System Name Synopsis: Any 24 characters

Configuring the System Information 111 Chapter 4 RUGGEDCOM ROS System Administration User Guide

Parameter Description The system name is displayed in all RUGGEDCOM ROS menu screens. This can make it easier to identify the switches within your network provided that all switches are given a unique name.

Location Synopsis: Any 49 characters The location can be used to indicate the physical location of the switch. It is displayed in the login screen as another means to ensure you are dealing with the desired switch.

Contact Synopsis: Any 49 characters The contact can be used to help identify the person responsible for managing the switch. You can enter name, phone number, email, etc. It is displayed in the login screen so that this person may be contacted should help be required.

3. Click Apply.

Section 4.2 Customizing the Login Screen

To display a custom welcome message, device information or any other information on the login screen for the Web and console interfaces, add text to the banner.txt file stored on the device. If the banner.txt file is empty, only the Username and Password fields appear on the login screen. To update the banner.txt file, download the file from the device, modify it and then load it back on to the device. For information about uploading and downloading files, refer to Section 3.4, “Uploading/Downloading Files” .

Section 4.3 Configuring Passwords

RUGGEDCOM ROS allows for up to three user profiles to be configured locally on the device. Each profile corresponds to one of the following access levels: • Guest • Operator • Admin The access levels provide or restrict the user's ability to change settings and execute various commands.

User Type Rights Guest Operator Admin

View Settings ü ü ü

Clear Logs û ü ü

Reset Alarms û ü ü

Clear Statistics û ü ü

112 Customizing the Login Screen RUGGEDCOM ROS Chapter 4 User Guide System Administration

User Type Rights Guest Operator Admin

Change Basic Settings û ü ü

Change Advanced Settings û û ü

Run Commands û û ü

Default passwords are configured for each user type initially. It is strongly recommended that these be changed before the device is commissioned.

NOTE Users can also be verified through a RADIUS or TACACS+ server. When enabled for authentication and authorization, the RADIUS or TACACS+ server will be used in the absence of any local settings. For more information about configuring a RADIUS or TACACS+ server, refer to Section 4.8, “Managing an Authentication Server” .

CAUTION! To prevent unauthorized access to the device, make sure to change the default passwords for each profile before commissioning the device.

To configure passwords for one or more of the user profiles, do the following: 1. Navigate to Administration » Configure Passwords . The Configure Passwords form appears.

1

2

3

4

5

6

7

8

9

10

11

12 13

Figure 65: Configure Passwords Form 1. Auth Type Box 2. Guest Username Box 3. Guest Password Box 4. Confirm Guest Password Box 5. Operator Username Box 6. Operator Password Box 7. Confirm Operator Password Box 8. Admin Username Box 9. Admin Password Box 10. Confirm Admin Password Box 11. Password Minimum Length box 12. Apply Button 13. Reload Button

Configuring Passwords 113 Chapter 4 RUGGEDCOM ROS System Administration User Guide

NOTE RUGGEDCOM ROS requires that all user passwords meet strict guidelines to prevent the use of weak passwords. When creating a new password, make sure it adheres to the following rules: • Must not be less than 8 characters in length. • Must not include the username or any 4 continous characters found in the username. For example, if the username is Subnet25, the password may not be subnet25admin, subnetadmin or net25admin. However, net-25admin or Sub25admin is permitted. • Must have at least one alphabetic character and one number. Special characters are permitted. • Must not have more than 3 continuously incrementing or decrementing numbers. For example, Sub123 and Sub19826 are permitted, but Sub12345 is not. An alarm will generate if a weak password is configured. The weak password alarm can be disabled by the user. For more information about disabling alarms, refer to Section 4.6, “Managing Alarms” .

2. Configure the following parameter(s) as required:

Parameter Description

Auth Type Synopsis: { Local, RADIUS, TACACS+, RADIUSorLocal, TACACS +orLocal } Default: Local Password can be authenticated using localy configured values, or remote RADIUS or TACACS+ server. Setting value to any of combinations that involve RADIUS or TACACS+ require Security Server Table to be configured. Settings: • Local - Authentication from the local Password Table. • RADIUS - Authentication using a RADIUS server. • TACACS+ - Authentication using a TACACS+ server. • RADIUSOrLocal - Authentication using RADIUS. If the server cannot be reached, authenticate from the local Password Table. • TACACS+OrLocal - Authentication using TACACS+. If the server cannot be reached, authenticate from the local Password Table

NOTE For console access, local credentials will always be checked first regardless of the device configuration. If server authentication is required, requests to the server will be sent only if local authentication fails.

Guest Username Synopsis: Any 15 characters Default: guest Related password is in field Guest Password; view only, cannot change settings or run any commands.

Guest Password Synopsis: 19 character ASCII string Related username is in field Guest Username; view only, cannot change settings or run any commands.

Confirm Guest Password Synopsis: 19 character ASCII string Related username is in field Guest Username; view only, cannot change settings or run any commands.

Operator Username Synopsis: Any 15 characters Default: operator

114 Configuring Passwords RUGGEDCOM ROS Chapter 4 User Guide System Administration

Parameter Description Related password is in field Oper Password; cannot change settings; can reset alarms, statistics, logs, etc.

Operator Password Synopsis: 19 character ASCII string Related username is in field Oper Username; cannot change settings; can reset alarms, statistics, logs, etc

Confirm Operator Password Synopsis: 19 character ASCII string Related username is in field Oper Username; cannot change settings; can reset alarms, statistics, logs, etc.

Admin Username Synopsis: Any 15 characters Default: admin Related password is in field Admin Password; full read/write access to all settings and commands.

Admin Password Synopsis: 19 character ASCII string Related username is in field Admin Username; full read/write access to all settings and commands.

Confirm Admin Password Synopsis: 19 character ASCII string Related username is in field Admin Username; full read/write access to all settings and commands.

Password Minimum Length Synopsis: 1 to 17 Default: 1 Configure the password string minimum length. The new password shorter than the minimum length will be rejected.

3. Click Apply.

Section 4.4 Clearing Private Data

When enabled, during system boot up, a user with serial console access can clear all configuration data and keys stored on the device, and restore all user names and passwords to factory default settings. To clear private data, do the following:

NOTE The commands used in the following procedure are time-sensitive. If the specified time limits are exceeded before providing the appropriate response, the device will continue normal boot up.

1. Connect to the device via the RS-232 serial console port. For more information, refer to Section 2.1.1, “Connecting Directly” . 2. Cycle power to the device. As the device is booting up, the following prompt will appear:

Press any key to start 3. Within four seconds, press CTRL + r. The access banner will appear, followed by the command prompt:

> 4. Type the following command, then press Enter within 30 seconds:

Clearing Private Data 115 Chapter 4 RUGGEDCOM ROS System Administration User Guide

clear private data 5. When prompted "Do you want to clear private data (Yes/No)?", answer yes and press Enter within five seconds. All configuration and keys in flash will be zeroized. An entry in the event log will be created. Crashlog.txt files (if existing) and syslog.txt files will be preserved. The device will reboot automatically.

Section 4.5 Enabling/Disabling the Web Interface

In some cases, users may want to disable the web interface to increase cyber security. To disable or enable the web interface, do the following:

NOTE The web interface can be disabled via the web UI by configuring the Web Server Users Allowed parameter in the IP Services form. For more information, refer to Section 3.9, “Configuring IP Services” .

1. Log in to the device as an admin user and access the CLI shell. For more information about accessing the CLI shell, refer to Section 2.6, “Using the Command Line Interface” . 2. Navigate to Administration » Configure IP Services » Web Server Users Allowed . 3. Select Disabled to disable the web interface, or select the desired number of web server users allowed to enable the interface.

Section 4.6 Managing Alarms

Alarms indicate the occurrence of events of either importance or interest that are logged by the device. There are two types of alarms: • Active alarms signify states of operation that are not in accordance with normal operation. Examples include links that should be up, but are not, or error rates that repeatedly exceed a certain threshold. These alarms are continuously active and are only cleared when the problem that triggered the alarms is resolved. • Passive alarms are a record of abnormal conditions that occurred in the past and do not affect th current operation state of the device. Examples include authentication failures, Remote Network MONitoring (RMON) MIB generated alarms, or error states that temporarily exceeded a certain threshold . These alarms can be cleared from the list of alarms.

NOTE For more information about RMON alarms, refer to Section 3.10.2, “Managing RMON Alarms” .

When either type of alarm occurs, a message appears in the top right corner of the user interface. If more than one alarm has occurred, the message will indicate the number of alarms. Active alarms also trip the Critical Failure Relay LED on the device. The message and the LED will remain active until the alarm is cleared.

116 Enabling/Disabling the Web Interface RUGGEDCOM ROS Chapter 4 User Guide System Administration

NOTE Alarms are volatile in nature. All alarms (active and passive) are cleared at startup.

CONTENTS • Section 4.6.1, “Viewing a List of Pre-Configured Alarms” • Section 4.6.2, “Viewing and Clearing Latched Alarms” • Section 4.6.3, “Configuring an Alarm” • Section 4.6.4, “Authentication Related Security Alarms”

Section 4.6.1 Viewing a List of Pre-Configured Alarms

To view a list of alarms pre-configured for the device, navigate to Diagnostic » Configure Alarms . The Alarms table appears.

Figure 66: Alarms Table

Viewing a List of Pre-Configured Alarms 117 Chapter 4 RUGGEDCOM ROS System Administration User Guide

NOTE This list of alarms (configurable and non-configurable) is accessible through the Command Line Interface (CLI) using the alarms. For more information, refer to Section 2.6.1, “Available CLI Commands” .

For information about modifying a pre-configured alarm, refer to Section 4.6.3, “Configuring an Alarm” .

Section 4.6.2 Viewing and Clearing Latched Alarms

To view a list of alarms that are configured to latch, navigate to Diagnostics » View Latched Alarms . The Latched Alarms table appears.

Figure 67: Latched Alarms Table

To clear the passive alarms from the list, do the following: 1. Navigate to Diagnostics » Clear Latched Alarms . The Clear Latched Alarms form appears.

1

Figure 68: Clear Latched Alarms Form 1. Confirm Button

2. Click Confirm.

Section 4.6.3 Configuring an Alarm

While all alarms are pre-configured on the device, some alarms can be modified to suit the application. This includes enabling/disabling certain features and changing the refresh time. To configuring an alarm, do the following:

118 Viewing and Clearing Latched Alarms RUGGEDCOM ROS Chapter 4 User Guide System Administration

IMPORTANT! Critical and Alert level alarms are not configurable and cannot be disabled.

1. Navigate to Diagnostic » Configure Alarms . The Alarms table appears.

Figure 69: Alarms Table

2. Select an alarm. The Alarms form appears.

Configuring an Alarm 119 Chapter 4 RUGGEDCOM ROS System Administration User Guide

1

2

3

4

5

6

7

8 9

Figure 70: Alarms Form 1. Name Box 2. Level Box 3. Latch Box 4. Trap Box 5. Log Box 6. LED & Relay Box 7. Refresh Time Box 8. Apply Button 9. Reload Button

3. Configure the following parameter(s) as required:

Parameter Description

Name Synopsis: Any 34 characters Default: sys_alarm The alarm name, as obtained through the alarms CLI command. Level Synopsis: { EMRG, ALRT, CRIT, ERRO, WARN, NOTE, INFO, DEBG } Severity level of the alarm: • EMERG - The device has had a serious failure that caused a system reboot. • ALERT - The device has had a serious failure that did not cause a system reboot. • CRITICAL - The device has a serious unrecoverable problem. • ERROR - The device has a recoverable problem that does not seriously affect operation. • WARNING - Possibly serious problem affecting overall system operation. • NOTIFY - Condition detected that is not expected or not allowed. • INFO - Event which is a part of normal operation, e.g. cold start, user login etc. • DEBUG - Intended for factory troubleshooting only. This parameter is not configurable.

Latch Synopsis: { On, Off } Default: Off Enables latching occurrence of this alarm in the Alarms Table.

Trap Synopsis: { On, Off } Default: Off Enables sending an SNMP trap for this alarm.

Log Synopsis: { On, Off } Default: Off

120 Configuring an Alarm RUGGEDCOM ROS Chapter 4 User Guide System Administration

Parameter Description Enables logging the occurrence of this alarm in syslog.txt.

LED & Relay Synopsis: { On, Off } Default: Off Enables LED and fail-safe relay control for this alarm. If latching is not enabled, this field will remain disabled.

Refresh Time Synopsis: 0 s to 60 s Default: 60 s Refreshing time for this alarm.

4. Click Apply.

Section 4.6.4 Authentication Related Security Alarms

This section describes the authentication-related security messages that can be generated by RUGGEDCOM ROS.

CONTENTS • Section 4.6.4.1, “Security Alarms for Login Authentication” • Section 4.6.4.2, “Security Messages for Port Authentication”

Section 4.6.4.1 Security Alarms for Login Authentication

RUGGEDCOM ROS provides various logging options related to login authentication. A user can log into a RUGGEDCOM ROS device in three different ways: Console, SSH or Telnet. RUGGEDCOM ROS can log messages in the syslog, send a trap to notify an SNMP manager, and/or raise an alarm when a successful and unsuccessful login event occurs. In addition, when a weak password is configured on a unit or when the primary authentication server for TACACS+ or RADIUS is not reachable, RUGGEDCOM ROS will raise alarms, send SNMP traps and log messages in the syslog. The following is a list of log and alarm messages related to user authentication: • Weak Password Configured • Login and Logout Information • Excessive Failed Login Attempts • RADIUS Server Unreachable • TACACS Server Unreachable • TACACS Response Invalid • SNMP Authentication Failure

NOTE All alarms and log messages related to login authentication are configurable. For more information about configuring alarms, refer to Section 4.6.3, “Configuring an Alarm” .

Authentication Related Security Alarms 121 Chapter 4 RUGGEDCOM ROS System Administration User Guide

Weak Password Configured RUGGEDCOM ROS generates this alarm and logs a message in the syslog when a weak password is configured in the Passwords table.

Message Name Alarm SNMP Trap Syslog

Weak Password Configured Yes Yes Yes

Default Keys In Use RUGGEDCOM ROS generates this alarm and logs a message in the syslog when default keys are in use. For more information about default keys, refer to Section 1.9, “SSH and SSL Keys and Certificates” .

NOTE For Non-Controlled (NC) versions of RUGGEDCOM ROS, this alarm is only generated when default SSL keys are in use.

Message Name Alarm SNMP Trap Syslog

Default Keys In Use Yes Yes Yes

Login and Logout Information RUGGEDCOM ROS generates this alarm and logs a message in the syslog when a successful and unsuccessful login attempt occurs. A message is also logged in the syslog when a user with a certain privilege level is logged out from the device. Login attempts are logged regardless of how the user accesses the device (i.e. SSH, Web, Console, Telnet or RSH). However, when a user logs out, a message is only logged when the user is accessing the device through SSH, Telnet or Console.

Message Name Alarm SNMP Trap Syslog

Successful Login Yes Yes Yes

Failed Login Yes Yes Yes

User Logout No No Yes

Excessive Failed Login Attempts RUGGEDCOM ROS generates this alarm and logs a message in the syslog after 10 failed login attempts by a user occur within a span of five minutes. Furthermore, the service the user attempted to access will be blocked for one hour to prevent further attempts.

Message Name Alarm SNMP Trap Syslog

Excessive Failed Login Attempts Yes Yes Yes

RADIUS Server Unreachable RUGGEDCOM ROS generates this alarm and logs a message in the syslog when the primary RADIUS server is unreachable.

122 Security Alarms for Login Authentication RUGGEDCOM ROS Chapter 4 User Guide System Administration

Message Name Alarm SNMP Trap Syslog

Primary RADIUS Server Yes Yes Yes Unreachable

TACACS+ Server Unreachable RUGGEDCOM ROS generates this alarm and logs a message in the syslog when the primary TACACS+ server is unreachable.

Message Name Alarm SNMP Trap Syslog

Primary TACACS Server Yes Yes Yes Unreachable

TACACS+ Response Invalid RUGGEDCOM ROS generate this alarm and logs a message in the syslog when the response from the TACACS+ server is received with an invalid CRC.

Message Name Alarm SNMP Trap Syslog

TACACS Response Invalid Yes Yes Yes

SNMP Authentication Failure RUGGEDCOM ROS generates this alarm, sends an authentication failure trap, and logs a message in the syslog when an SNMP manager with incorrect credentials communicates with the SNMP agent in RUGGEDCOM ROS.

Message Name Alarm SNMP Trap Syslog

SNMP Authentication Failure Yes Yes Yes

Section 4.6.4.2 Security Messages for Port Authentication

The following is the list of log and alarm messages related to port access control in RUGGEDCOM ROS: • MAC Address Authorization Failure • Secure Port X Learned MAC Addr on VLAN X • Port Security Violated

MAC Address Authorization Failure RUGGEDCOM ROS generates this alarm and logs a message in the syslog when a host connected to a secure port on the device is communicating using a source MAC address which has not been authorized by RUGGEDCOM ROS, or the dynamically learned MAC address has exceeded the total number of MAC addresses configured to be learned dynamically on the secured port. This message is only applicable when the port security mode is set to Static MAC.

Security Messages for Port Authentication 123 Chapter 4 RUGGEDCOM ROS System Administration User Guide

Message Name Alarm SNMP Trap Syslog

MAC Address Authorization Yes Yes Yes Failure

Secure Port X Learned MAC Addr on VLAN X RUGGEDCOM ROS logs a message in the syslog and sends a configuration change trap when a MAC address is learned on a secure port. Port X indicates the secured port number and VLAN number on that port. This message is not configurable in RUGGEDCOM ROS.

Message Name SNMP Trap Syslog

Secure Port X Learned MAC Addr on VLAN X Yes Yes

Port Security Violated This message is only applicable when the security mode for a port is set to "802.1X or 802.1X/MAC-Auth" RUGGEDCOM ROS this alarm and logs a message in the syslog when the host connected to a secure port tries to communicate using incorrect login credentials.

Message Name Alarm SNMP Trap Syslog

802.1X Port X Authentication Yes Yes Yes Failure

802.1X Port X Authorized Addr. No No Yes XXX

Section 4.7 Managing the Configuration File

The device configuration file for RUGGEDCOM ROS is a single CSV (Comma-Separate Value) formatted ASCII text file, named config.csv. It can be downloaded from the device to view, compare against other configuration files, or store for backup purposes. It can also be overwritten by a complete or partial configuration file uploaded to the device. To prevent unauthorized access to the contents of the configuration file, the file can be encrypted and given a password/passphrase key.

CONTENTS • Section 4.7.1, “Configuring Data Encryption” • Section 4.7.2, “Updating the Configuration File”

Section 4.7.1 Configuring Data Encryption

To encrypt the configuration file and protect it with a password/passphrase, do the following:

124 Managing the Configuration File RUGGEDCOM ROS Chapter 4 User Guide System Administration

NOTE Data encryption is not available in Non-Controlled (NC) versions of RUGGEDCOM ROS. When switching between Controlled and Non-Controlled (NC) versions of RUGGEDCOM ROS, make sure data encryption is disabled. Otherwise, the NC version of RUGGEDCOM ROS will ignore the encrypted configuration file and load the factory defaults.

NOTE Only configuration data is encrypted. All comments and table names in the configuration file are saved as clear text.

NOTE When sharing a configuration file between devices, make sure both devices have the same passphrase configured. Otherwise, the configuration file will be rejected.

NOTE Encryption must be disabled before the device is returned to Siemens or the configuration file is shared with Customer Support.

IMPORTANT! Never downgrade the RUGGEDCOM ROS software version beyond RUGGEDCOM ROS v4.3 when encryption is enabled. Make sure the device has been restored to factory defaults before downgrading.

1. Navigate to Administration » Configure Data Storage . The Data Storage form appears.

1

2

3

4 5

Figure 71: Data Storage Form 1. Encryption Options 2. Passphrase Box 3. Confirm Passphrase Box 4. Apply Button 5. Reload Button

2. Configure the following parameter(s) as required:

Parameter Description

Encryption Synopsis: { On, Off } Enable/disable encryption of data in configuration file.

Passphrase Synopsis: 31 character ascii string This passphrase is used as a secret key to encrypt the configuration data. Encrypted data can be decrypted by any device configured with the same passphrase.

Confirm Passphrase Synopsis: 31 character ascii string

Configuring Data Encryption 125 Chapter 4 RUGGEDCOM ROS System Administration User Guide

Parameter Description This passphrase is used as a secret key to encrypt the configuration data. Encrypted data can be decrypted by any device configured with the same passphrase.

3. Click Apply.

Section 4.7.2 Updating the Configuration File

Once downloaded from the device, the configuration file can be updated using a variety of different tools:

NOTE For information about uploading/downloading files, refer to Section 3.4, “Uploading/Downloading Files” .

• Any text editing program capable of reading and writing ASCII files • Difference/patching tools (e.g. the UNIX diff and patch command line utilities) • Source Code Control systems (e.g. CVS, SVN)

CAUTION! Configuration hazard – risk of data loss. Do not edit an encrypted configuration file. Any line that has been modified manually will be ignored.

RUGGEDCOM ROS also has the ability to accept partial configuration updates. For example, to update only the parameters for Ethernet port 1 and leave all other parameters unchanged, transfer a file containing only the following lines to the device:

# Port Parameters ethPortCfg Port,Name,Media,State,AutoN,Speed,Dupx,FlowCtrl,LFI,Alarm, 1,Port 1,100TX,Enabled,On,Auto,Auto,Off,Off,On,

Section 4.8 Managing an Authentication Server

The following section describes how to setup and configure an authentication server.

CONTENTS • Section 4.8.1, “Managing RADIUS Authentication”

126 Updating the Configuration File RUGGEDCOM ROS Chapter 4 User Guide System Administration

• Section 4.8.2, “Managing TACACS+ Authentication”

Section 4.8.1 Managing RADIUS Authentication

RUGGEDCOM ROS can be configured to act as a RADIUS client and forward user credentials to a RADIUS (Remote Authentication Dial In User Service) server for remote authentication and authorization. RADIUS is a UDP-based protocol used for carrying authentication, authorization and configuration information between a Network Access Server (NAS) that desires to authenticate its links and a shared authentication server. It provides centralized authentication and authorization for network access. RADIUS is also widely used in conjunction with the IEEE 802.1X standard for port security using the Extensible Authentication Protocol (EAP).

NOTE For more information about the RADIUS protocol, refer to RFC 2865. For more information about the Extensible Authentication Protocol (EAP), refer to RFC 3748.

IMPORTANT! RADIUS messages are sent as UDP messages. The switch and the RADIUS server must use the same authentication and encryption key.

IMPORTANT! RUGGEDCOM ROS supports both Protected Extensible Authentication Protocol (PEAP) and EAP-MD5. PEAP is more secure and is recommended if available in the supplicant.

In a RADIUS access request, the following attributes and values are typically sent by the RADIUS client to the RADIUS server:

Attribute Value

User-Name { Guest, Operator, Admin }

User-Password { password }

Service-Type 1

Vendor-Specific Vendor-ID: 15004 Type: 1 Length: 11 String: RuggedCom A RADIUS server may also be used to authenticate access on ports with 802.1X security support. When this is required, the following attributes are sent by the RADIUS client to the RADIUS server:

Attribute Value

User-Name { The username as derived from the client's EAP identity response }

NAS-IP-Address { The Network Access Server IP address }

Service-Type 2

Frame-MTU 1500

Managing RADIUS Authentication 127 Chapter 4 RUGGEDCOM ROS System Administration User Guide

Attribute Value

EAP-Messagea { A message(s) received from the authenticating peer }

a EAP-Message is an extension attribute for RADIUS, as defined by RFC 2869.

CONTENTS • Section 4.8.1.1, “Configuring the RADIUS Server” • Section 4.8.1.2, “Configuring the RADIUS Client”

Section 4.8.1.1 Configuring the RADIUS Server

The Vendor-Specific attribute (or VSA) sent to the RADIUS server as part of the RADIUS request is used to determine the access level from the RADIUS server. This attribute may be configured within the RADIUS server with the following information:

Attribute Value

Vendor-Specific Vendor-ID: 15004 Format: String Number: 2 Attribute: { Guest, Operator, Admin }

NOTE If no access level is received in the response packet from the RADIUS server, access is denied.

Section 4.8.1.2 Configuring the RADIUS Client

The RADIUS client can be configured to use two RADIUS servers: a primary server and a backup server. If the primary server is unavailable, the device will automatically attempt to connect with the backup server.

NOTE The RADIUS client uses the Password Authentication Protocol (PAP) to verify access.

To configure access to either the primary or backup RADIUS servers, do the following: 1. Navigate to Administration » Configure Security Server » Configure RADIUS Server . The RADIUS Server table appears.

128 Configuring the RADIUS Server RUGGEDCOM ROS Chapter 4 User Guide System Administration

Figure 72: RADIUS Server Table

2. Select either Primary or Backup from the table. The RADIUS Server form appears.

1

2

3

4

5 6 7

Figure 73: RADIUS Server Form 1. Server Box 2. IP Address Box 3. Auth UDP Port Box 4. Auth Key Box 5. Confirm Auth Key Box 6. Apply Button 7. Reload Button

3. Configure the following parameter(s) as required:

Parameter Description

Server Synopsis: Any 8 characters Default: Primary This field tells whether this configuration is for a Primary or a Backup Server.

IP Address Synopsis: ###.###.###.### where ### ranges from 0 to 255 The Server IP Address.

Auth UDP Port Synopsis: 1 to 65535 Default: 1812 The IP Port on server.

Auth Key Synopsis: 31 character ASCII string The authentication key to be shared with server.

Confirm Auth Key Synopsis: 31 character ASCII string The authentication key to be shared with server.

4. Click Apply.

Configuring the RADIUS Client 129 Chapter 4 RUGGEDCOM ROS System Administration User Guide

Section 4.8.2 Managing TACACS+ Authentication

TACACS+ (Terminal Access Controller Access-Control System Plus) is a TCP-based access control protocol that provides authentication, authorization and accounting services to routers, Network Access Servers (NAS) and other networked computing devices via one or more centralized servers. The following section describes how to configure TACACs+ authentication.

CONTENTS • Section 4.8.2.1, “Configuring TACACS+” • Section 4.8.2.2, “Configuring User Privileges”

Section 4.8.2.1 Configuring TACACS+

RUGGEDCOM ROS can be configured to use two TACACS+ servers: a primary server and a backup server. If the primary server is unavailable, the device will automatically attempt to connect with the backup server. To configure access to either the primary or backup TACACS+ servers, do the following: 1. Navigate to Administration » Configure Security Server » Configure TacPlus Server » Configure TACACS Plus Server . The TACACS Plus Server table appears.

Figure 74: TACACS Plus Server Table

2. Select either Primary or Backup from the table. The TACACS Plus Server form appears.

130 Managing TACACS+ Authentication RUGGEDCOM ROS Chapter 4 User Guide System Administration

1

2

3

4

5

6 7

Figure 75: TACACS Plus Server Form 1. Server Box 2. IP Address Box 3. Auth TCP Port Box 4. Auth Key Box 5. Confirm Key Box 6. Apply Button 7. Reload Button

3. Configure the following parameter(s) as required:

Parameter Description

Server Synopsis: Any 8 characters Default: Primary This field tells whether this configuration is for a Primary or a Backup Server.

IP Address Synopsis: ###.###.###.### where ### ranges from 0 to 255 The Server IP Address.

Auth TCP Port Synopsis: 1 to 65535 Default: 49 The IP Port on server.

Auth Key Synopsis: 31 character ascii string Default: mySecret The authentication key to be shared with server.

Confirm Auth Key Synopsis: 31 character ascii string The authentication key to be shared with server.

4. Set the privilege levels for each user type (i.e. admin, operator and guest). For more information, refer to Section 4.8.2.2, “Configuring User Privileges” . 5. Click Apply.

Section 4.8.2.2 Configuring User Privileges

Each TACACS+ authentication request includes a priv_lvl attribute that is used to grant access to the device. By default, the attribute uses the following ranges: • 15 represents the admin access level • 2-14 represents the operator access level • 1 represents the guest access level

Configuring User Privileges 131 Chapter 4 RUGGEDCOM ROS System Administration User Guide

To configure the privilege levels for each user type, do the following: 1. Navigate to Administration » Configure Security Server » Configure TacPlus Server » Configure TACPLUS Serv Privilege Config . The TACPLUS Serv Privilege Config form appears.

1

2

3

4 5

Figure 76: TACPLUS Serv Privilege Config Form 1. Admin Priv Box 2. Oper Priv Box 3. Guest Priv Box 4. Apply Button 5. Reload Button

2. Configure the following parameter(s) as required:

Parameter Description

Admin Priv Synopsis: (0 to 15)-(0 to 15) Default: 15 Privilege level to be assigned to the user.

Oper Priv Synopsis: (0 to 15)-(0 to 15) Default: 2-14 Privilege level to be assigned to the user.

Guest Priv Synopsis: (0 to 15)-(0 to 15) Default: 1 Privilege level to be assigned to the user.

3. Click Apply.

132 Configuring User Privileges RUGGEDCOM ROS Chapter 5 User Guide Setup and Configuration

Setup and Configuration

This chapter describes how to setup and configure the device for use on a network using the various features available in RUGGEDCOM ROS.

CONTENTS • Section 5.1, “Managing Virtual LANs” • Section 5.2, “Managing Spanning Tree Protocol” • Section 5.3, “Managing Classes of Service” • Section 5.4, “Managing MAC Addresses” • Section 5.5, “Managing Time Services” • Section 5.6, “Managing SNMP” • Section 5.7, “Managing Network Discovery” • Section 5.8, “Managing Multicast Filtering” • Section 5.9, “Managing Port Security” • Section 5.10, “Managing Link Aggregation”

Section 5.1 Managing Virtual LANs

A Virtual Local Area Network (VLAN) is a group of devices on one or more LAN segments that communicate as if they were attached to the same physical LAN segment. VLANs are extremely flexible because they are based on logical connections, rather than physical connections. When VLANs are introduced, all traffic in the network must belong to one VLAN or another. Traffic on one VLAN cannot pass to another, except through an inter-network router or Layer 3 switch. VLANs are created in three ways: • Explicitly Static VLANs can be created in the switch. For more information about static VLANs, refer to Section 5.1.5, “Managing Static VLANs” . • Implicitly When a VLAN ID (VID) is set for a port-based VLAN, static MAC address or IP interface, an appropriate VLAN is automatically created if it does not yet exist. • Dynamically VLANs can be learned through GVRP. For more information about GVRP, refer to Section 5.1.1.8, “GARP VLAN Registration Protocol (GVRP)” For more information about VLANs, refer to Section 5.1.1, “VLAN Concepts” .

CONTENTS • Section 5.1.1, “VLAN Concepts”

Managing Virtual LANs 133 Chapter 5 RUGGEDCOM ROS Setup and Configuration User Guide

• Section 5.1.2, “Viewing a List of VLANs” • Section 5.1.3, “Configuring VLANs Globally” • Section 5.1.4, “Configuring VLANs for Specific Ethernet Ports” • Section 5.1.5, “Managing Static VLANs”

Section 5.1.1 VLAN Concepts

The following section describes some of the concepts important to the implementation of VLANs in RUGGEDCOM ROS.

CONTENTS • Section 5.1.1.1, “Tagged vs. Untagged Frames” • Section 5.1.1.2, “Native VLAN” • Section 5.1.1.3, “The Management VLAN” • Section 5.1.1.4, “Edge and Trunk Port Types” • Section 5.1.1.5, “Ingress and Egress Rules” • Section 5.1.1.6, “Forbidden Ports List” • Section 5.1.1.7, “VLAN-Aware and VLAN-Unaware Modes” • Section 5.1.1.8, “GARP VLAN Registration Protocol (GVRP)” • Section 5.1.1.9, “PVLAN Edge” • Section 5.1.1.10, “QinQ” • Section 5.1.1.11, “VLAN Advantages”

Section 5.1.1.1 Tagged vs. Untagged Frames

VLAN tags identify frames as part of a VLAN network. When a switch receives a frame with a VLAN (or 802.1Q) tag, the VLAN identifier (VID) is extracted and the frame is forwarded to other ports on the same VLAN. When a frame does not contain a VLAN tag, or contains an 802.1p (prioritization) tag that only has prioritization information and a VID of 0, it is considered an untagged frame.

Section 5.1.1.2 Native VLAN

Each port is assigned a native VLAN number, the Port VLAN ID (PVID). When an untagged frame ingresses a port, it is associated with the port's native VLAN. By default, when a switch transmits a frame on the native VLAN, it sends the frame untagged. The switch can be configured to transmit tagged frames on the native VLAN.

134 VLAN Concepts RUGGEDCOM ROS Chapter 5 User Guide Setup and Configuration

Section 5.1.1.3 The Management VLAN

Management traffic, like all traffic on the network, must belong to a specific VLAN. The management VLAN is configurable and always defaults to VLAN 1. This VLAN is also the default native VLAN for all ports, thus allowing all ports the possibility of managing the product. Changing the management VLAN can be used to restrict management access to a specific set of users.

Section 5.1.1.4 Edge and Trunk Port Types

Each port can be configured as an edge or trunk port. An edge port attaches to a single end device, such as a PC or Intelligent Electronic Device (IED). An edge port carries traffic on the native VLAN. Trunk ports are part of the network and carry traffic for all VLANs between switches. Trunk ports are automatically members of all VLANs configured in the switch. The switch can 'pass through' traffic, forwarding frames received on one trunk port out of another trunk port. The trunk ports must be members of all VLANs that the 'pass through' traffic is part of, even if none of those VLANs are used on edge ports. Frames transmitted out of the port on all VLANs other than the port's native VLAN are always sent tagged.

NOTE It may be desirable to manually restrict the traffic on the trunk to a specific group of VLANs. For example, when the trunk connects to a device, such as a Layer 3 router, that supports a subset of the available LANs. To prevent the trunk port from being a member of the VLAN, include it in the VLAN's Forbidden Ports list. For more information about the Forbidden Ports list, refer to Section 5.1.1.6, “Forbidden Ports List” .

Port Type VLANs Supported PVID Format Usage

Edge 1 (Native) Untagged VLAN Unaware Networks: All frames are sent and received without Configured the need for VLAN tags.

Tagged VLAN Aware Networks: VLAN traffic domains are enforced on a single VLAN.

Trunk All Configured Tagged or Untagged Switch-to-Switch Connections: VLANs must be manually created and administered, or can be dynamically learned through GVRP. Multiple-VLAN End Devices: Implement connections to end devices that support multiple VLANs at the same time.

Section 5.1.1.5 Ingress and Egress Rules

Ingress and egress rules determine how traffic is received and transmitted by the switch. Ingress rules are applied as follows to all frame when they are received by the switch:

The Management VLAN 135 Chapter 5 RUGGEDCOM ROS Setup and Configuration User Guide

a Priority Tagged Frame Received Untagged Tagged (Valid VID) (VID = 0)

VLAN ID associated with the frame PVID PVID VID in the Tag

Frame dropped due to its tagged/untagged format No No No

Frame dropped if the ingress port is not a member of the VLAN the Yes frame is associated with and ingress filtering is enabled

a Does not depend on the ingress port's VLAN configuration parameters.

Egress rules are applied as follows to all frames when they are transmitted by the switch.

On Other VLAN Egress Port Type On Egress Port's Native VLAN Port Is Not a Member Port Is a Member Of the VLAN Of the VLAN

Edge According to the egress port's Dropped PVID Format parameter Trunk Tagged Dropped

Section 5.1.1.6 Forbidden Ports List

Each VLAN can be configured to exclude ports from membership in the VLAN using the forbidden ports list. For more information, refer to Section 5.1.5.2, “Adding a Static VLAN” .

Section 5.1.1.7 VLAN-Aware and VLAN-Unaware Modes

The native operation mode for an IEEE 802.1Q compliant switch is VLAN-aware. Even if a specific network architecture does not use VLANs, RUGGEDCOM ROS's default VLAN settings allow the switch to still operate in a VLAN-aware mode, while providing functionality required for almost any network application. However, the IEEE 802.1Q standard defines a set of rules that must be followed by all VLAN-aware switches: • Valid VIDs are within the range of 1 to 4094. VIDs equal to 0 or 4095 are invalid. • Each frame ingressing a VLAN-aware switch is associated with a valid VID. • Each frame egressing a VLAN-aware switch is either untagged or tagged with a valid VID. Priority-tagged frames with an invalid VID will never sent out by a VLAN-aware switch.

NOTE Some applications have requirements conflicting with IEEE 802.Q1 native mode of operation. For example, some applications explicitly require priority-tagged frames to be received by end devices. To avoid conflicts and provide full compatibility with legacy (VLAN-unaware) devices, RUGGEDCOM ROS can be configured to work in VLAN-unaware mode. In that mode: • Frames ingressing a VLAN-unaware device are not associated with any VLAN • Frames egressing a VLAN-unaware device are sent out unmodified (i.e. in the same untagged, 802.1Q-tagged or priority-tagged format as they were received)

136 Forbidden Ports List RUGGEDCOM ROS Chapter 5 User Guide Setup and Configuration

Section 5.1.1.8 GARP VLAN Registration Protocol (GVRP)

GARP VLAN Registration Protocol (GVRP) is a standard protocol built on GARP (Generic Attribute Registration Protocol) to automatically distribute VLAN configuration information in a network. Each switch in a network needs only to be configured with VLANs it requires locally. VLANs configured elsewhere in the network are learned through GVRP. A GVRP-aware end station (i.e. PC or Intelligent Electronic Device) configured for a particular VID can be connected to a trunk on a GVRP-aware switch and automatically become part of the desired VLAN. When a switch sends GVRP bridge protocol data units (BPDUs) out of all GVRP-enabled ports, GVRP BPDUs advertise all the VLANs known to that switch (configured manually or learned dynamically through GVRP) to the rest of the network. When a GVRP-enabled switch receives a GVRP BPDU advertising a set of VLANs, the receiving port becomes a member of those advertised VLANs and the switch begins advertising those VLANs through all the GVRP-enabled ports (other than the port on which the VLANs were learned). To improve network security using VLANs, GVRP-enabled ports may be configured to prohibit the learning of any new dynamic VLANs but at the same time be allowed to advertise the VLANs configured on the switch. The following is an example of how to use GVRP:

D

D2 D

D1

B3 B B1 B2 B4

A1 A E1 E C1 C 1

A2 E2 C2

A E C 2

Figure 77: Using GVRP 1. Switch 2. End Node

• Switch B is the core switch, all others are edge switches • Ports A1, B1 to B4, C1, D1, D2 and E1 are GVRP aware

GARP VLAN Registration Protocol (GVRP) 137 Chapter 5 RUGGEDCOM ROS Setup and Configuration User Guide

• Ports B1 to B4, D1 and D2 are set to advertise and learn • Ports A1, C1 and E1 are set to advertise only • Ports A2, C2 and E2 are edge ports • End node D is GVRP aware • End nodes A, E and C are GVRP unaware • Ports A2 and C2 are configured with PVID 7 • Port E2 is configured with PVID 20 • End node D is interested in VLAN 20, hence VLAN 20 is advertised by it towards switch D • D2 becomes a member of VLAN 20 • Ports A1 and C1 advertise VID 7 • Ports B1 and B2 become members of VLAN 7 • Ports B1, B2 and D1 advertise VID 20 • Ports B3, B4 and D1 become members of VLAN 20 For more information about how to configure GVRP, refer to Section 5.1.4, “Configuring VLANs for Specific Ethernet Ports” .

Section 5.1.1.9 PVLAN Edge

Private VLAN (PVLAN) Edge isolates multiple VLAN Edge ports from each other on a single device. When VLAN Edge ports are configured as protected, they are prohibited from sending frames to one another, but are still permitted to send frames to other, non-protected ports within the same VLAN. This protection extends to all traffic on the VLAN, including unicast, multicast and broadcast traffic. For more information about how to configure a port as protected, refer to Section 5.1.4, “Configuring VLANs for Specific Ethernet Ports” .

NOTE This feature is strictly local to the switch. PVLAN Edge ports are not prevented from communicating with ports outside of the switch, whether protected (remotely) or not.

Section 5.1.1.10 QinQ

QinQ, also referred to as Stacked VLANs, port bridging, double VLAN-tagging and Nested VLANs, is used to overlay a private Layer 2 network over a public Layer 2 network. A large network service provider, for example, might have several clients whose networks each use multiple VLANs. It is likely the VLAN IDs used by these different client networks would conflict with one another, were they mixed together in the provider's network. Using double QinQ, each client network could be further tagged using a client-specific VID at the edges where the clients' networks are connected to the network service provider's infrastructure. Any tagged frames ingressing an edge port of the service provider's switch are tagged with VIDs of the customer’s private network. When those frames egress the switch's QinQ-enabled port into the service provider network, the switch always adds an extra tag (called an outer tag) on top of the frame's original VLAN tag (called an inner tag).

138 PVLAN Edge RUGGEDCOM ROS Chapter 5 User Guide Setup and Configuration

The outer tag VID is the PVID of the frame's ingress edge port. This means that traffic from an individual customer is tagged with their unique VID and is thus segregated from other customer's traffic. For untagged ingress frames, the switch will only add the outer VLAN tag. Within the service provider network, switching is based on the VID in the outer tag. When double-tagged frames leave the service provider network, they egress a QinQ-enabled port of another switch. The switch strips the outer tag while associating the frames with the VID extracted from it before stripping. Thus, the frames are switched to appropriate edge ports ( i.e. customers). The following figure shows an example of traffic flow using QinQ. For tagged frames: • Frames received from customer 1 with VID 100 would carry an inner tag of 100 and an outer tag of VID X (i.e. VLAN 110) which is configured on the edge port connected to customer 1. • Next, the frames from customer 1 are forwarded through the QinQ port carrying an inner and an outer tag. • Finally, upon arrival of the frames in the peer switch, the outer VLAN tag is removed and the frames are forwarded with the inner VLAN tag towards customer 1. For untagged frames: • Frames received from customer 2 would carry an outer tag of VID Y(i.e VLAN 220) which is configured on the edge port connected to customer 2. • Next, the frames from customer 2 are forwarded through the QinQ port carrying the outer tag. • Finally, upon arrival of the frames in the peer switch, the outer VLAN tag is removed before the frames are forwarded to customer 2.

2 1

5 5

4 4

3

1 2

Figure 78: Using QinQ 1. Customer 1 (PVID is X) 2. Customer 2 (PVID is Y) 3. Network Service Provider Infrastructure 4. Switch 5. QinQ

NOTE Depending on the hardware installed, some switch models allow only one switch port be configured to QinQ mode at a time.

NOTE When QinQ is enabled, all non-QinQ ports will be untagged and cannot be changed, and all QinQ ports will be tagged, and cannot be changed.

QinQ 139 Chapter 5 RUGGEDCOM ROS Setup and Configuration User Guide

Section 5.1.1.11 VLAN Advantages

The following are a few of the advantages offered by VLANs.

Traffic Domain Isolation VLANs are most often used for their ability to restrict traffic flows between groups of devices. Unnecessary broadcast traffic can be restricted to the VLAN that requires it. Broadcast storms in one VLAN need not affect users in other VLANs. Hosts on one VLAN can be prevented from accidentally or deliberately assuming the IP address of a host on another VLAN. The use of creative bridge filtering and multiple VLANs can carve seemingly unified IP subnets into multiple regions policed by different security/access policies. Multi-VLAN hosts can assign different traffic types to different VLANs.

1 3

2

2 4 5

Figure 79: Multiple Overlapping VLANs 1. VLAN 2. Switch

Administrative Convenience VLANs enable equipment moves to be handled by software reconfiguration instead of by physical cable management. When a host's physical location is changed, its connection point is often changed as well. With VLANs, the host's VLAN membership and priority are simply copied to the new port.

Reduced Hardware Without VLANs, traffic domain isolation requires the use of separate bridges for separate networks. VLANs eliminate the need for separate bridges. The number of network hosts may often be reduced. Often, a server is assigned to provide services for independent networks. These hosts may be replaced by a single, multi-horned host supporting each network on its own VLAN. This host can perform routing between VLANs. Multi-VLAN hosts can assign different traffic types to different VLANs.

140 VLAN Advantages RUGGEDCOM ROS Chapter 5 User Guide Setup and Configuration

3 199.85.245.1/25

1 4 199.85.245.128/26

2

5 199.85.245.192/26

Figure 80: Inter-VLAN Communications 1. Server, Router or Layer 3 Switch 2. Switch 3. VLAN 2 4. VLAN 3 5. VLAN 4

Section 5.1.2 Viewing a List of VLANs

To view a list of all VLANs, whether they were created statically, implicitly or dynamically , navigate to Virtual LANs » View VLAN Summary . The VLAN Summary table appears.

Figure 81: VLAN Summary Table

If a VLANs are not listed, add static VLANs as needed. For more information, refer to Section 5.1.5.2, “Adding a Static VLAN” .

Section 5.1.3 Configuring VLANs Globally

To configure global settings for all VLANs, do the following: 1. Navigate to Virtual LANs » Configure Global VLAN Parameters . The Global VLAN Parameters form appears.

Viewing a List of VLANs 141 Chapter 5 RUGGEDCOM ROS Setup and Configuration User Guide

1

2

3

4 5

Figure 82: Global VLAN Parameters Form 1. VLAN-aware Options 2. Ingress Filtering Options 3. QinQ Outer TPID options 4. Apply Button 5. Reload Button

2. Configure the following parameter(s) as required:

Parameter Description

VLAN-aware Synopsis: { No, Yes } Default: Yes Set either VLAN-aware or VLAN-unaware mode of operation.

Ingress Filtering Synopsis: { Disabled, Enabled } Default: Disabled Enables or disables VLAN ingress filtering on all ports. When enabled, any tagged packet arriving at a port, which is not a member of a VLAN with which that packet is associated, is dropped. When disabled, packets are not dropped.

NOTE Ingress filtering has no effect when ports are in either VLAN-unaware mode or Q-in-Q mode.

QinQ Outer TPID Synopsis: { 0x8100, 0x88A8 } Default: 0x8100 Selects an Ethertype to be used as the Tag Protocol Identifier (TPID) on VLAN QinQ ports when QinQ is enabled. Frames that ingress a VLAN QinQ port will be identified as outer VLAN tagged if the first Ethertype matches this value; an outer VLAN tag with the TPID field assigned to this value will be inserted to frames that egress a VLAN QinQ port.

NOTE When QinQ is enabled, all non-QinQ ports will be untagged and cannot be changed, and all QinQ ports will be tagged, and cannot be changed.

3. Click Apply.

142 Configuring VLANs Globally RUGGEDCOM ROS Chapter 5 User Guide Setup and Configuration

Section 5.1.4 Configuring VLANs for Specific Ethernet Ports

When a VLAN ID is assigned to an Ethernet port, the VLAN appears in the VLAN Summary table where it can be further configured. To configure a VLAN for a specific Ethernet port, do the following: 1. Navigate to Virtual LANs » Configure Port VLAN Parameters . The Port VLAN Parameters table appears.

Figure 83: Port VLAN Parameters Table

2. Select a port. The Port VLAN Parameters form appears.

1

2

3

4

5

6 7

Figure 84: Port VLAN Parameters Form 1. Port(s) Box 2. Type List 3. PVID Box 4. PVID Format Options 5. GVRP List 6. Apply Button 7. Reload Button

3. Configure the following parameter(s) as required:

Parameter Description

Port(s) Synopsis: Any combination of numbers valid for this parameter The port number as seen on the front plate silkscreen of the switch (or a list of ports, if aggregated in a port trunk).

Type Synopsis: { Edge, Trunk, PVLANEdge, QinQ }

Configuring VLANs for Specific Ethernet Ports 143 Chapter 5 RUGGEDCOM ROS Setup and Configuration User Guide

Parameter Description Default: Edge This parameter specifies how the port determines its membership in VLANs. There are few types of ports: • Edge - the port is only a member of one VLAN (its native VLAN specified by the PVID parameter). • Trunk - the port is automatically a member of all configured VLANs. Frames transmitted out of the port on all VLANs except the port's native VLAN will be always tagged. It can also be configured to use GVRP for automatic VLAN configuration. • PVLANEdge - the port is only a member of one VLAN (its native VLAN specified by the PVID parameter), and does not forward traffic to other PVLANedge ports within the same VLAN. • QinQ - the port is a trunk port using double-VLAN tagging, or nested VLANs. An extra VLAN tag is always added to all frames egressing this port. VID in the added extra tag is the PVID of the frame's ingress port. VLAN tag is always stripped from frames ingressing this port.

NOTE Depending on the hardware installed, some switch models allow only one switch port be configured to QinQ mode at a time.

PVID Synopsis: 1 to 4094 Default: 1 The Port VLAN Identifier specifies the VLAN ID associated with untagged (and 802.1p priority tagged) frames received on this port. Frames tagged with a non-zero VLAN ID will always be associated with the VLAN ID retrieved from the frame tag. Modify this parameter with care! By default, the switch is programmed to use VLAN 1 for management and every port on the switch is programmed to use VLAN 1. If you modify a switch port to use a VLAN other than the management VLAN, devices on that port will not be able to manage the switch.

PVID Format Synopsis: { Untagged, Tagged } Default: Untagged Specifies whether frames transmitted out of the port on its native VLAN (specified by the PVID parameter) will be tagged or untagged.

NOTE When QinQ is enabled, all non-QinQ ports will be untagged and cannot be changed, and all QinQ ports will be tagged, and cannot be changed.

GVRP Synopsis: { Adv&Learn, Adv Only, Disabled } Default: Disabled Configures GVRP (Generic VLAN Registration Protocol) operation on the port. There are several GVRP operation modes: • DISABLED - the port is not capable of any GVRP processing. • ADVERTISE ONLY - the port will declare all VLANs existing in the switch (configured or learned) but will not learn any VLANs. • ADVERTISE & LEARN - the port will declare all VLANs existing in the switch (configured or learned) and can dynamically learn VLANs. Only Trunk ports are GVRP-capable.

144 Configuring VLANs for Specific Ethernet Ports RUGGEDCOM ROS Chapter 5 User Guide Setup and Configuration

4. Click Apply.

Section 5.1.5 Managing Static VLANs

The following section describes how to configure and manage static VLANs.

CONTENTS • Section 5.1.5.1, “Viewing a List of Static VLANs” • Section 5.1.5.2, “Adding a Static VLAN” • Section 5.1.5.3, “Deleting a Static VLAN”

Section 5.1.5.1 Viewing a List of Static VLANs

To view a list of static VLANs, navigate to Virtual LANs » Configure Static VLANs . The Static VLANs table appears.

Figure 85: Static VLANs Table

If a static VLAN is not listed, add the VLAN. For more information, refer to Section 5.1.5.2, “Adding a Static VLAN” .

Section 5.1.5.2 Adding a Static VLAN

To add a static VLAN, do the following: 1. Navigate to Virtual LANs » Configure Static VLANs . The Static VLANs table appears.

Managing Static VLANs 145 Chapter 5 RUGGEDCOM ROS Setup and Configuration User Guide

1

Figure 86: Static VLANs Table 1. InsertRecord

2. Click InsertRecord. The Static VLANs form appears.

1

2

3

4

5

6 8

7

Figure 87: Static VLANs Form 1. VID Box 2. VLAN Name Box 3. Forbidden Ports Box 4. IGMP Options 5. MSTI Box 6. Apply Button 7. Delete Button 8. Reload Button

3. Configure the following parameter(s) as required:

NOTE If IGMP Options is not enabled for the VLAN, both IGMP messages and multicast streams will be forwarded directly to all members of the VLAN. If any one member of the VLAN joins a multicast group, then all members of the VLAN will receive the multicast traffic.

Parameter Description

VID Synopsis: 1 to 4094 Synopsis: 1 to 4094 Default: 1

146 Adding a Static VLAN RUGGEDCOM ROS Chapter 5 User Guide Setup and Configuration

Parameter Description The VLAN Identifier is used to identify the VLAN in tagged Ethernet frames according to IEEE 802.1Q.

VLAN Name Synopsis: Any 19 characters The VLAN name provides a description of the VLAN purpose (for example, Engineering VLAN).

Forbidden Ports Synopsis: Any combination of numbers valid for this parameter These are ports that are not allowed to be members of the VLAN. Examples: • None - all ports of the switch are allowed to be members of the VLAN • 2,4-6,8 - all ports except ports 2, 4, 6, 7 and 8 are allowed to be members of the VLAN

IGMP Synopsis: { Off, On } Default: Off This parameter enables or disables IGMP Snooping on the VLAN.

MSTI Synopsis: 0 to 16 Default: 0 This parameter is only valid for Multiple Spanning Tree Protocol (MSTP) and has no effect if MSTP is not used. The parameter specifies the Multiple Spanning Tree Instance (MSTI) to which the VLAN should be mapped.

4. Click Apply.

Section 5.1.5.3 Deleting a Static VLAN

To delete a static VLAN, do the following: 1. Navigate to Virtual LANs » Configure Static VLANs . The Static VLANs table appears.

Figure 88: Static VLANs Table

2. Select the static VLAN from the table. The Static VLANs form appears.

Deleting a Static VLAN 147 Chapter 5 RUGGEDCOM ROS Setup and Configuration User Guide

1

2

3

4

5

6 8

7

Figure 89: Static VLANs Form 1. VID Box 2. VLAN Name Box 3. Forbidden Ports Box 4. IGMP Options 5. MSTI Box 6. Apply Button 7. Delete Button 8. Reload Button

3. Click Delete.

Section 5.2 Managing Spanning Tree Protocol

CONTENTS • Section 5.2.1, “RSTP Operation” • Section 5.2.2, “RSTP Applications” • Section 5.2.3, “MSTP Operation” • Section 5.2.4, “Configuring STP Globally” • Section 5.2.5, “Configuring STP for Specific Ethernet Ports” • Section 5.2.6, “Configuring eRSTP” • Section 5.2.7, “Viewing Global Statistics for STP” • Section 5.2.8, “Viewing STP Statistics for Ethernet Ports” • Section 5.2.9, “Managing Multiple Spanning Tree Instances” • Section 5.2.10, “Clearing Spanning Tree Protocol Statistics”

Section 5.2.1 RSTP Operation

The 802.1D Spanning Tree Protocol (STP) was developed to enable the construction of robust networks that incorporate redundancy while pruning the active topology of the network to prevent loops. While STP is effective,

148 Managing Spanning Tree Protocol RUGGEDCOM ROS Chapter 5 User Guide Setup and Configuration

it requires that frame transfer halt after a link outage until all bridges in the network are guaranteed to be aware of the new topology. Using the values recommended by 802.1D, this period lasts 30 seconds. The Rapid Spanning Tree Protocol (RSTP, IEEE 802.1w) was a further evolution of the 802.1D Spanning Tree Protocol. It replaced the settling period with an active handshake between bridges that guarantees the rapid propagation of topology information throughout the network. RSTP also offers a number of other significant innovations, including: • Topology changes in RSTP can originate from and be acted upon by any designated bridges, leading to more rapid propagation of address information, unlike topology changes in STP, which must be passed to the root bridge before they can be propagated to the network. • RSTP explicitly recognizes two blocking roles - Alternate and Backup Port - which are included in computations of when to learn and forward. STP, however, recognizes only one state - Blocking - for ports that should not forward. • RSTP bridges generate their own configuration messages, even if they fail to receive any from the root bridge. This leads to quicker failure detection. STP, by contrast, must relay configuration messages received on the root port out its designated ports. If an STP bridge fails to receive a message from its neighbor, it cannot be sure where along the path to the root a failure occurred. • RSTP offers edge port recognition, allowing ports at the edge of the network to forward frames immediately after activation, while at the same time protecting them against loops. While providing much better performance than STP, IEEE 802.1w RSTP still required up to several seconds to restore network connectivity when a topology change occurred. A revised and highly optimized RSTP version was defined in the IEEE standard 802.1D-2004 edition. IEEE 802.1D-2004 RSTP reduces network recovery times to just milliseconds and optimizes RSTP operation for various scenarios. RUGGEDCOM ROS supports IEEE 802.1D-2004 RSTP.

CONTENTS • Section 5.2.1.1, “RSTP States and Roles” • Section 5.2.1.2, “Edge Ports” • Section 5.2.1.3, “Point-to-Point and Multipoint Links” • Section 5.2.1.4, “Path and Port Costs” • Section 5.2.1.5, “Bridge Diameter” • Section 5.2.1.6, “eRSTP” • Section 5.2.1.7, “Fast Root Failover”

Section 5.2.1.1 RSTP States and Roles

RSTP bridges have roles to play, either root or designated. One bridge - the Root Bridge - is the logical center of the network. All other bridges in the network are Designated bridges. RSTP also assigns each port of the bridge a state and a role. The RSTP state describes what is happening at the port in relation to address learning and frame forwarding. The RSTP role basically describes whether the port is facing the center or the edges of the network and whether it can currently be used.

RSTP States and Roles 149 Chapter 5 RUGGEDCOM ROS Setup and Configuration User Guide

State There are three RSTP states: Discarding, Learning and Forwarding. The discarding state is entered when the port is first put into service. The port does not learn addresses in this state and does not participate in frame transfer. The port looks for RSTP traffic in order to determine its role in the network. When it is determined that the port will play an active part in the network, the state will change to learning. The learning state is entered when the port is preparing to play an active part in the network. The port learns addresses in this state but does not participate in frame transfer. In a network of RSTP bridges, the time spent in this state is usually quite short. RSTP bridges operating in STP compatibility mode will spend six to 40 seconds in this state. After learning, the bridge will place the port in the forwarding state. The port both learns addresses and participates in frame transfer while in this state.

IMPORTANT! RUGGEDCOM ROS introduces two more states - Disabled and Link Down. Introduced purely for purposes of management, these states may be considered subclasses of the RSTP Discarding state. The Disabled state refers to links for which RSTP has been disabled. The Link Down state refers to links for which RSTP is enabled but are currently down.

Role There are four RSTP port roles: Root, Designated, Alternate and Backup. If the bridge is not the root bridge, it must have a single Root Port. The Root Port is the "best” (i.e. quickest) way to send traffic to the root bridge. A port is marked as Designated if it is the best port to serve the LAN segment it is connected to. All bridges on the same LAN segment listen to each others’ messages and agree on which bridge is the Designated Bridge. The ports of other bridges on the segment must become either Root, Alternate or Backup ports.

150 RSTP States and Roles RUGGEDCOM ROS Chapter 5 User Guide Setup and Configuration

1 C 3 1 2

3 3

4 4

1 1

2 2

2 3 2

5 6 3

D

Figure 90: Bridge and Port Roles 1. Root Bridge 2. Designated Bridge 3. Designated Port 4. Root Port 5. Alternate Port 6. Backup Port

A port is alternate when it receives a better message from another bridge on the LAN segment it is connected to. The message that an Alternate Port receives is better than the port itself would generate, but not good enough to convince it to become the Root Port. The port becomes the alternate to the current Root Port and will become the new Root Port should the current Root Port fail. The Alternate Port does not participate in the network. A port is a Backup Port when it receives a better message from the LAN segment it is connected to, originating from another port on the same bridge. The port is a backup for another port on the bridge and will become active if that port fails. The Backup Port does not participate in the network.

Section 5.2.1.2 Edge Ports

A port may be designated as an Edge Port if it is directly connected to an end station. As such, it cannot create bridging loops in the network and can thus directly transition to forwarding, skipping the listening and learning stages. Edge ports that receive configuration messages immediately lose their Edge Port status and become normal spanning tree ports. A loop created on an improperly connected edge port is thus quickly repaired. Because an Edge Port services only end stations, topology change messages are not generated when its link toggles.

Edge Ports 151 Chapter 5 RUGGEDCOM ROS Setup and Configuration User Guide

Section 5.2.1.3 Point-to-Point and Multipoint Links

RSTP uses a peer-peer protocol called Proposing-Agreeing to ensure transitioning in the event of a link failure. This protocol is point-to-point and breaks down in multipoint situations, i.e. when more than two bridges operate on a shared media link. If RSTP detects this circumstance (based upon the port’s half duplex state after link up) it will switch off Proposing- Agreeing. The port must transition through the learning and forwarding states, spending one forward delay in each state. There are circumstances in which RSTP will make an incorrect decision about the point-to-point state of the link simply by examining the half-duplex status, namely: • The port attaches only to a single partner, but through a half-duplex link. • The port attaches to a shared media hub through a full-duplex link. The shared media link attaches to more than one RSTP enabled bridge. In such cases, the user may configure the bridge to override the half-duplex determination mechanism and force the link to be treated in the proper fashion.

Section 5.2.1.4 Path and Port Costs

The STP path cost is the main metric by which root and designated ports are chosen. The path cost for a designated bridge is the sum of the individual port costs of the links between the root bridge and that designated bridge. The port with the lowest path cost is the best route to the root bridge and is chosen as the root port.

NOTE In actuality the primary determinant for root port selection is the root bridge ID. Bridge ID is important mainly at network startup when the bridge with the lowest ID is elected as the root bridge. After startup (when all bridges agree on the root bridge’s ID) the path cost is used to select root ports. If the path costs of candidates for the root port are the same, the ID of the peer bridge is used to select the port. Finally, if candidate root ports have the same path cost and peer bridge ID, the port ID of the peer bridge is used to select the root port. In all cases the lower ID, path cost or port ID is selected as the best.

How Port Costs Are Generated Port costs can be generated either as a result of link auto-negotiation or manual configuration. When the link auto-negotiation method is used, the port cost is derived from the speed of the link. This method is useful when a well-connected network has been established. It can be used when the designer is not too concerned with the resultant topology as long as connectivity is assured. Manual configuration is useful when the exact topology of the network must be predictable under all circumstances. The path cost can be used to establish the topology of the network exactly as the designer intends.

STP vs. RSTP Costs The IEEE 802.1D-1998 specification limits port costs to values of 1 to 65536. Designed at a time when 9600 bps links were state of the art, this method breaks down in modern use, as the method cannot represent a link speed higher than 10 gigabits per second.

152 Point-to-Point and Multipoint Links RUGGEDCOM ROS Chapter 5 User Guide Setup and Configuration

To remedy this problem in future applications, the IEEE 802.1w specification limits port costs to values of 1 to 20000000, and a link speed up to 10 Tb per second can be represented with a value of 2. RUGGEDCOM bridges support interoperability with legacy STP bridges by selecting the style to use. In practice, it makes no difference which style is used as long as it is applied consistently across the network, or if costs are manually assigned.

Section 5.2.1.5 Bridge Diameter

The bridge diameter is the maximum number of bridges between any two possible points of attachment of end stations to the network. The bridge diameter reflects the realization that topology information requires time to propagate hop by hop through a network. If configuration messages take too long to propagate end to end through the network, the result will be an unstable network. There is a relationship between the bridge diameter and the maximum age parameter. To achieve extended ring sizes, Siemens eRSTP™ uses an age increment of ¼ of a second. The value of the maximum bridge diameter is thus four times the configured maximum age parameter.

NOTE The RSTP algorithm is as follows: • STP configuration messages contain age information. • Messages transmitted by the root bridge have an age of 0. As each subsequent designated bridge transmits the configuration message it must increase the age by at least 1 second. • When the age exceeds the value of the maximum age parameter the next bridge to receive the message immediately discards it.

IMPORTANT! Raise the value of the maximum age parameter if implementing very large bridged networks or rings.

Section 5.2.1.6 eRSTP

Siemens's enhanced Rapid Spanning Tree Protocol (eRSTP) improves the performance of RSTP in two ways: • Improves the fault recovery time performance (< 5 ms per hop) • Improves performance for large ring network topologies (up to 80 switches) eRSTP is also compatible with standard RSTP for interoperability with commercial switches. For example, in a network comprised of 15 RUGGEDCOM hardened Ethernet switches in a ring topology, the expected fault recovery time would be less than 75 ms (i.e. 5 ms x 15). However, with eRSTP, the worst case fault recovery time is less than 26 ms.

Bridge Diameter 153 Chapter 5 RUGGEDCOM ROS Setup and Configuration User Guide

Section 5.2.1.7 Fast Root Failover

Siemens’s Fast Root Failover feature is an enhancement to RSTP that may be enabled or disabled. Fast Root Failover improves upon RSTP’s handling of root bridge failures in mesh-connected networks.

IMPORTANT! In networks mixing RUGGEDCOM and non-RUGGEDCOM switches, or in those mixing Fast Root Failover algorithms, RSTP Fast Root Failover will not function properly and root bridge failure will result in an unpredictable failover time. To avoid potential issues, note the following: • When using the Robust algorithm, all switches must be RUGGEDCOM switches • When using the Relaxed algorithm, all switches must be RUGGEDCOM switches, with the exception of the root switch • All RUGGEDCOM switches in the network must use the same Fast Root Failover algorithm

Two Fast Root Failover algorithms are available: • Robust – Guarantees a deterministic root failover time, but requires support from all switches in the network, including the root switch • Relaxed – Ensures a deterministic root failover time in most network configurations, but allows the use of a standard bridge in the root role

NOTE The minimum interval for root failures is one second. Multiple, near simultaneous root failures (within less than one second of each other) are not supported by Fast Root Failover.

Fast Root Failover and RSTP Performance • Running RSTP with Fast Root Failover disabled has no impact on RSTP performance in ring-connected networks. • Fast Root Failover has no effect on RSTP performance in the case of failures that do not involve the root bridge or one of its links. • The extra processing introduced by Fast Root Failover significantly decreases the worst-case failover time due to root bridge failure in mesh networks.

Recommendations On the Use of Fast Root Failover • It is not recommended to enable Fast Root Failover in single ring network topologies. • It is strongly recommended to always connect the root bridge to each of its neighbor bridges using more than one link when enabled in ring-connected networks.

Section 5.2.2 RSTP Applications

The following section describes various applications of RSTP.

CONTENTS • Section 5.2.2.1, “RSTP in Structured Wiring Configurations”

154 Fast Root Failover RUGGEDCOM ROS Chapter 5 User Guide Setup and Configuration

• Section 5.2.2.2, “RSTP in Ring Backbone Configurations” • Section 5.2.2.3, “RSTP Port Redundancy”

Section 5.2.2.1 RSTP in Structured Wiring Configurations

RSTP may be used to construct structured wiring systems where connectivity is maintained in the event of link failures. For example, a single link failure of any link between A and N in Figure 91 would leave all the ports of bridges 555 through 888 connected to the network.

1 A 1 111 222 2 B 2 4 3 4 3

C F

D E

1 2 1 2 444 444 6 3 6 3 5 4 5 4

G I H K J M L N

1 2 1 2 1 2 1 2 555 666 777 888

4 3 4 3 4 3 4 3

Figure 91: Example - Structured Wiring Configuration

To design a structured wiring configuration, do the following: 1. Select the design parameters for the network. What are the requirements for robustness and network failover/recovery times? Are there any special requirements for diverse routing to a central host computer? Are there any special port redundancy requirements?

RSTP in Structured Wiring Configurations 155 Chapter 5 RUGGEDCOM ROS Setup and Configuration User Guide

2. Identify required legacy support. Are STP bridges used in the network? These bridges do not support rapid transitioning to forwarding. If these bridges are present, can they be re-deployed closer to the network edge? 3. Identify edge ports and ports with half-duplex/shared media restrictions. Ports that connect to host computers, Intelligent Electronic Devices (IEDs) and controllers may be set to edge ports in order to guarantee rapid transitioning to forwarding as well as to reduce the number of topology change notifications in the network. Ports with half-duplex/shared media restrictions require special attention in order to guarantee that they do not cause extended fail-over/recovery times. 4. Choose the root bridge and backup root bridge carefully. The root bridge should be selected to be at the concentration point of network traffic. Locate the backup root bridge adjacent to the root bridge. One strategy that may be used is to tune the bridge priority to establish the root bridge and then tune each bridge’s priority to correspond to its distance from the root bridge. 5. Identify desired steady state topology. Identify the desired steady state topology taking into account link speeds, offered traffic and QOS. Examine of the effects of breaking selected links, taking into account network loading and the quality of alternate links. 6. Decide upon a port cost calculation strategy. Select whether fixed or auto-negotiated costs should be used? It is recommended to use the auto-negotiated cost style, unless it is necessary for the network design to change the auto-negotiated cost style. Select whether the STP or RSTP cost style should be used. Make sure to configure the same cost style on all devices on the network. 7. Enable RSTP Fast Root Failover option. This is a proprietary feature of Siemens. In a mesh network with only RUGGEDCOM devices in the core of the network, it is recommended to enable the RSTP Fast Root Failover option to minimize the network downtime in the event of a Root bridge failure. 8. Calculate and configure priorities and costs. 9. Implement the network and test under load.

Section 5.2.2.2 RSTP in Ring Backbone Configurations

RSTP may be used in ring backbone configurations where rapid recovery from link failure is required. In normal operation, RSTP will block traffic on one of the links, for example, as indicated by the double bars through link H in Figure 92 . In the event of a failure on link D, bridge 444 will unblock link H. Bridge 333 will communicate with the network through link F.

156 RSTP in Ring Backbone Configurations RUGGEDCOM ROS Chapter 5 User Guide Setup and Configuration

A 1 111 222 B 1 2 C 3 3

L D

1 K 3 666 333 2 E 2 3

J F

1 1 I 3 2 H 3 555 444 2 G

Figure 92: Example - Ring Backbone Configuration

To design a ring backbone configuration with RSTP, do the following: 1. Select the design parameters for the network. What are the requirements for robustness and network fail-over/recovery times? Typically, ring backbones are chosen to provide cost effective but robust network designs. 2. Identify required legacy support and ports with half-duplex/shared media restrictions. These bridges should not be used if network fail-over/recovery times are to be minimized. 3. Identify edge ports. Ports that connect to host computers, Intelligent Electronic Devices (IEDs) and controllers may be set to edge ports in order to guarantee rapid transitioning to forwarding as well as to reduce the number of topology change notifications in the network. 4. Choose the root bridge. The root bridge can be selected to equalize either the number of bridges, number of stations or amount of traffic on either of its legs. It is important to realize that the ring will always be broken in one spot and that traffic always flows through the root.

RSTP in Ring Backbone Configurations 157 Chapter 5 RUGGEDCOM ROS Setup and Configuration User Guide

5. Assign bridge priorities to the ring. The strategy that should be used is to assign each bridge’s priority to correspond to its distance from the root bridge. If the root bridge is assigned the lowest priority of 0, the bridges on either side should use a priority of 4096 and the next bridges 8192 and so on. As there are 16 levels of bridge priority available, this method provides for up to 31 bridges in the ring. 6. Decide upon a port cost calculation strategy. It is recommended to use the auto-negotiated cost style, unless it is necessary for the network design to change the auto-negotiated cost style. Select whether the STP or RSTP cost style should be used. Make sure to configure the same cost style on all devices on the network. 7. Disable RSTP Fast Root Failover option. This is a proprietary feature of Siemens. In RUGGEDCOM ROS, the RSTP Fast Root Failover option is enabled by default. It is recommended to disable this feature when operating in a Ring network. 8. Implement the network and test under load.

Section 5.2.2.3 RSTP Port Redundancy

In cases where port redundancy is essential, RSTP allows more than one bridge port to service a LAN. In the following example, if port 3 is designated to carry the network traffic of LAN A, port 4 will block traffic. Should an interface failure occur on port 3, port 4 will assume control of the LAN.

1 2

4 3

A

Figure 93: Example - Port Redundancy

Section 5.2.3 MSTP Operation

The Multiple Spanning Tree (MST) algorithm and protocol provide greater control and flexibility than RSTP and legacy STP. MSTP (Multiple Spanning Tree Protocol) is an extension of RSTP, whereby multiple spanning trees may be maintained on the same bridged network. Data traffic is allocated to one or another of several spanning trees by mapping one or more VLANs onto the network. The sophistication and utility of the Multiple Spanning Tree implementation on a given bridged network is proportional to the amount of planning and design invested in configuring MSTP. If MSTP is activated on some or all of the bridges in a network with no additional configuration, the result will be a fully and simply connected network, but at best, the result will be the same as a network using only RSTP. Taking full advantage of the features offered by MSTP requires a potentially large number of configuration variables

158 RSTP Port Redundancy RUGGEDCOM ROS Chapter 5 User Guide Setup and Configuration

to be derived from an analysis of data traffic on the bridged network, and from requirements for load sharing, redundancy, and path optimization. Once these parameters have all been derived, it is also critical that they are consistently applied and managed across all bridges in an MST region. By design, MSTP processing time is proportional to the number of active STP instances. This means that MSTP will likely be significantly slower than RSTP. Therefore, for mission critical applications, RSTP should be considered a better network redundancy solution than MSTP.

CONTENTS • Section 5.2.3.1, “MSTP Regions and Interoperability” • Section 5.2.3.2, “MSTP Bridge and Port Roles” • Section 5.2.3.3, “Benefits of MSTP” • Section 5.2.3.4, “Implementing MSTP on a Bridged Network”

Section 5.2.3.1 MSTP Regions and Interoperability

In addition to supporting multiple spanning trees in a network of MSTP-capable bridges, MSTP is capable of inter- operating with bridges that support only RSTP or legacy STP, without requiring any special configuration. An MST region may be defined as the set of interconnected bridges whose MST Region Identification is identical. The interface between MSTP bridges and non-MSTP bridges, or between MSTP bridges with different MST Region Identification information, becomes part of an MST Region boundary. Bridges outside an MST region will see the entire region as though it were a single (R)STP bridge; the internal detail of the MST region is hidden from the rest of the bridged network. In support of this, MSTP maintains separate hop counters for spanning tree information exchanged at the MST region boundary versus that propagated inside the region. For information received at the MST region boundary, the (R)STP Message Age is incremented only once. Inside the region, a separate Remaining Hop Count is maintained, one for each spanning tree instance. The external Message Age parameter is referred to the (R)STP Maximum Age Time, whereas the internal Remaining Hop Counts are compared to an MST region-wide Maximum Hops parameter.

MSTI An MSTI (Multiple Spanning Tree Instance) is one of sixteen independent spanning tree instances that may be defined in an MST region (not including the IST – see below). An MSTI is created by mapping a set of VLANs (in RUGGEDCOM ROS, via the VLAN configuration) to a given MSTI ID. The same mapping must be configured on all bridges that are intended to be part of the MSTI. Moreover, all VLAN to MSTI mappings must be identical for all bridges in an MST region. RUGGEDCOM ROS supports 16 MSTIs in addition to the IST. Each MSTI has a topology that is independent of every other. Data traffic originating from the same source and bound to the same destination but on different VLANs on different MSTIs may therefore travel a different path across the network.

IST An MST region always defines an IST (Internal Spanning Tree). The IST spans the entire MST region, and carries all data traffic that is not specifically allocated (by VLAN) to a specific MSTI. The IST is always computed and is defined to be MSTI zero.

MSTP Regions and Interoperability 159 Chapter 5 RUGGEDCOM ROS Setup and Configuration User Guide

The IST is also the extension inside the MST region of the CIST (see below), which spans the entire bridged network, inside and outside of the MST region and all other RSTP and STP bridges, as well as any other MST regions.

CST The CST (Common Spanning Tree) spans the entire bridged network, including MST regions and any connected STP or RSTP bridges. An MST region is seen by the CST as an individual bridge, with a single cost associated with its traversal.

CIST The CIST (Common and Internal Spanning Tree) is the union of the CST and the ISTs in all MST regions. The CIST therefore spans the entire bridged network, reaching into each MST region via the latter’s IST to reach every bridge on the network.

Section 5.2.3.2 MSTP Bridge and Port Roles

MSTP supports the following bridge and port roles:

Bridge Roles

Role Description

CIST Root The CIST Root is the elected root bridge of the CIST (Common and Internal Spanning Tree), which spans all connected STP and RSTP bridges and MSTP regions.

CIST Regional Root The root bridge of the IST within an MSTP region. The CIST Regional Root is the bridge within an MSTP region with the lowest cost path to the CIST Root. Note that the CIST Regional Root will be at the boundary of an MSTP region. Note also that it is possible for the CIST Regional Root to be the CIST Root.

MSTI Regional Root The root bridge for an MSTI within an MSTP region. A root bridge is independently elected for each MSTI in an MSTP region.

Port Roles Each port on an MSTP bridge may have more than one CIST role depending on the number and topology of spanning tree instances defined on the port.

Role Description

CIST Port Roles • The Root Port provides the minimum cost path from the bridge to the CIST Root via the CIST Regional Root. If the bridge itself happens to be the CIST Regional Root, the Root Port is also the Master Port for all MSTIs, and provides the minimum cost path to a CIST Root located outside the region. • A Designated Port provides the minimum cost path from an attached LAN, via the bridge to the CIST Regional Root.

160 MSTP Bridge and Port Roles RUGGEDCOM ROS Chapter 5 User Guide Setup and Configuration

Role Description • Alternate and Backup Ports function the same as they do in RSTP, but relative to the CIST Regional Root.

MSTI Port Roles For each MSTI on a bridge: • The Root Port provides the minimum cost path from the bridge to the MSTI Regional Root, if the bridge itself is not the MSTI Regional Root. • A Designated Port provides the minimum cost path from an attached LAN, via the bridge to the MSTI Regional Root. • Alternate and Backup Ports function the same as they do in RSTP, but relative to the MSTI Regional Root. The Master Port, which is unique in an MSTP region, is the CIST Root Port of the CIST Regional Root, and provides the minimum cost path to the CIST Root for all MSTIs.

Boundary Ports A Boundary Port is a port on a bridge in an MSTP region that connects to either: a bridge belonging to a different MSTP region, or a bridge supporting only RSTP or legacy STP. A Boundary Port blocks or forwards all VLANs from all MSTIs and the CIST alike. A Boundary Port may be: • The CIST Root Port of the CIST Regional Root (and therefore also the MSTI Master Port). • A CIST Designated Port, CIST Alternate/Backup Port, or Disabled. At the MSTP region boundary, the MSTI Port Role is the same as the CIST Port Role. A Boundary Port connected to an STP bridge will send only STP BPDUs. One connected to an RSTP bridge need not refrain from sending MSTP BPDUs. This is made possible by the fact that the MSTP carries the CIST Regional Root Identifier in the field that RSTP parses as the Designated Bridge Identifier.

Section 5.2.3.3 Benefits of MSTP

Despite the fact that MSTP is configured by default to arrive automatically at a spanning tree solution for each configured MSTI, advantages may be gained from influencing the topology of MSTIs in an MST region. The fact that the Bridge Priority and each port cost are configurable per MST makes it possible to control the topology of each MSTI within a region.

Load Balancing MSTP can be used to balance data traffic load among sets of VLANs, enabling more complete utilization of a multiply interconnected bridged network. A bridged network controlled by a single spanning tree will block redundant links by design, in order to avoid harmful loops. Using MSTP, however, any given link may have a different blocking state for MSTI, as maintained by MSTP. Any given link, therefore, might be in blocking state for some VLANs, and in forwarding state for other VLANs, depending on the mapping of VLANs to MSTIs. It is possible to control the spanning tree solution for each MSTI, especially the set of active links for each tree, by manipulating, per MSTI, the bridge priority and the port costs of links in the network. If traffic is allocated judiciously to multiple VLANs, redundant interconnections in a bridged network which, using a single spanning tree, would have gone unused, can now be made to carry traffic.

Benefits of MSTP 161 Chapter 5 RUGGEDCOM ROS Setup and Configuration User Guide

Isolation of Spanning Tree Reconfiguration. A link failure in an MSTP region that does not affect the roles of Boundary ports will not cause the CST to be reconfigured, nor will the change affect other MSTP regions. This is due to the fact that MSTP information does not propagate past a region boundary.

MSTP versus PVST An advantage of MSTP over the Cisco Systems Inc. proprietary PVST protocol is the ability to map multiple VLANs onto a single MSTI. Since each spanning tree requires processing and memory, the expense of keeping track of an increasing number of VLANs increases much more rapidly for PVST than for MSTP.

Compatibility with STP and RSTP No special configuration is required for the bridges of an MST region to connect fully and simply to non-MST bridges on the same bridged network. Careful planning and configuration is, however, recommended in order to arrive at an optimal network.

Section 5.2.3.4 Implementing MSTP on a Bridged Network

It is recommended the configuration of MSTP on a network proceed in the sequence outlined below. Naturally, it is also recommended that network analysis and planning inform the steps of configuring the VLAN and MSTP parameters in particular. Begin with a set of MSTP-capable Ethernet bridges and MSTP disabled. For each bridge in the network:

NOTE MSTP does not need to be enabled to map a VLAN to an MSTI. However, the mapping must be identical for each bridge that belongs to the MSTP region.

1. Configure and enable STP globally and/or for specific Ethernet ports. For more information, refer to Section 5.2.4, “Configuring STP Globally” or Section 5.2.5, “Configuring STP for Specific Ethernet Ports” .

NOTE Static VLANs must be used in an MSTP configuration. GVRP is not supported.

2. Add static VLANs and map them to MSTIs. For more information, refer to Section 5.1.5.2, “Adding a Static VLAN” .

NOTE The Region Identifier and Revision Level must be the same for each bridge in the MST region.

3. Configure the revision level for the MST Region Identifier. For more information, refer to Section 5.2.9.3, “Configuring the MST Region Identifier” . 4. Make sure the read-only digest for the MST Region Identifier is identical for each bridge in the MST region. If the digest is different, the set of mappings from VLANs to MSTIs differs. 5. Configure the Bridge Priority for the global MSTI. For more information, refer to Section 5.2.9.4, “Configuring a Global MSTI” .

162 Implementing MSTP on a Bridged Network RUGGEDCOM ROS Chapter 5 User Guide Setup and Configuration

6. Configure the Port Cost and Priority per Port for each MSTI. For more information, refer to Section 5.2.9.5, “Configuring an MSTI for an Ethernet Port” . 7. Set the STP Protocol Version to MSTP and enable STP. For more information, refer to Section 5.2.4, “Configuring STP Globally”

Section 5.2.4 Configuring STP Globally

To configure global settings for the Spanning Tree Protocol (STP), do the following: 1. Navigate to Spanning Tree » Configure Bridge RSTP Parameters . The Bridge RSTP Parameters form appears.

1

2

3

4

5

6

7

8

9 10

Figure 94: Bridge RSTP Parameters Form 1. State Options 2. Version Support List 3. Bridge Priority List 4. Hello Time Box 5. Max Age Time Box 6. Transmit Count Box 7. Forward Delay Box 8. Max Hops Box 9. Apply Button 10. Reload Button

2. Configure the following parameter(s) as required:

Parameter Description

State Synopsis: { Disabled, Enabled } Default: Enabled Enable STP/RSTP/MSTP for the bridge globally. Note that STP/RSTP/ MSTP is enabled on a port when it is enabled globally and along with enabling per port setting.

Version Support Synopsis: { STP, RSTP, MSTP } Default: RSTP Selects the version of Spanning Tree Protocol to support, either only STP or Rapid STP or Multiple STP.

Bridge Priority Synopsis: { 0, 4096, 8192, 12288, 16384, 20480, 24576, 28672, 32768, 36864, 40960, 45056, 49152, 53248, 57344, 61440 } Default: 32768

Configuring STP Globally 163 Chapter 5 RUGGEDCOM ROS Setup and Configuration User Guide

Parameter Description Bridge Priority provides a way to control the topology of the STP connected network. The desired Root and Designated bridges can be configured for a particular topology. The bridge with the lowest priority will become root. In the event of a failure of the root bridge, the bridge with the next lowest priority will then become root. Designated bridges that (for redundancy purposes) service a common LAN also use priority to determine which bridge is active. In this way careful selection of Bridge Priorities can establish the path of traffic flows in normal and abnormal conditions.

Hello Time Synopsis: 1 to 10 s Default: 2 s Time between configuration messages issued by the root bridge. Shorter hello times result in faster detection of topology changes at the expense of moderate increases in STP traffic.

Max Age Time Synopsis: 6 to 40 s Default: 20 s The time for which a configuration message remains valid after being issued by the root bridge. Configure this parameter with care when many tiers of bridges exist, or slow speed links (such as those used in WANs) are part of the network

Transmit Count Synopsis: 3 to 100 or { Unlimited } Default: Unlimited Maximum number of BPDUs on each port that may be sent in one second. Larger values allow the network to recover from failed links/bridges more quickly.

Forward Delay Synopsis: 4 to 30 s Default: 15 s The amount of time a bridge spends learning MAC addresses on a rising port before beginning to forward traffic. Lower values allow the port to reach the forwarding state more quickly, but at the expense of flooding unlearned addresses to all ports.

Max Hops Synopsis: 6 to 40 Default: 20 Only applicable to MSTP. The maximum possible bridge diameter inside an MST region. MSTP BPDUs propagating inside an MST region specify a time- to-live that is decremented by every switch that propagates the BPDU. If the maximum number of hops inside the region exceeds the configured maximum, BPDUs may be discarded due to their time-to-live setting.

3. Click Apply.

Section 5.2.5 Configuring STP for Specific Ethernet Ports

To configure the Spanning Tree Protocol (STP) for a specific Ethernet port, do the following: 1. Navigate to Spanning Tree » Configure Port RSTP Parameters . The Port RSTP Parameters table appears.

164 Configuring STP for Specific Ethernet Ports RUGGEDCOM ROS Chapter 5 User Guide Setup and Configuration

Figure 95: Port RSTP Parameters Table

2. Select an Ethernet port. The Port RSTP Parameters form appears.

1

2

3

4

5

6

7

8

9 10 11

Figure 96: Port RSTP Parameters Form 1. Port(s) Box 2. Enabled Options 3. Priority List 4. STP Cost Box 5. RSTP Cost Box 6. Edge Port List 7. Point to Point List 8. Restricted Role Box 9. Restricted TCN Box 10. Apply Button 11. Reload Button

3. Configure the following parameter(s) as required:

Parameter Description

Port(s) Synopsis: Any combination of numbers valid for this parameter The port number as seen on the front plate silkscreen of the switch (or a list of ports, if aggregated in a port trunk).

Enabled Synopsis: { Disabled, Enabled } Default: Enabled

Configuring STP for Specific Ethernet Ports 165 Chapter 5 RUGGEDCOM ROS Setup and Configuration User Guide

Parameter Description Enabling STP activates the STP or RSTP protocol for this port per the configuration in the STP Configuration menu. STP may be disabled for the port ONLY if the port does not attach to an STP enabled bridge in any way. Failure to meet this requirement WILL result in an undetectable traffic loop in the network. A better alternative to disabling the port is to leave STP enabled but to configure the port as an edge port. A good candidate for disabling STP would be a port that services only a single host computer.

Priority Synopsis: { 0, 16, 32, 48, 64, 80, 96, 112, 128, 144, 160, 176, 194, 208, 224, 240 } Default: 128 Selects the STP port priority. Ports of the same cost that attach to a common LAN will select the port to be used based upon the port priority.

STP Cost Synopsis: 0 to 65535 or { Auto } Default: Auto Selects the cost to use in cost calculations, when the Cost Style parameter is set to STP in the Bridge RSTP Parameters configuration. Setting the cost manually provides the ability to preferentially select specific ports to carry traffic over others. Leave this field set to "auto" to use the standard STP port costs as negotiated (4 for 1Gbps, 19 for 100 Mbps links and 100 for 10 Mbps links). For MSTP, this parameter applies to both external and internal path cost.

RSTP Cost Synopsis: 0 to 2147483647 or { Auto } Default: Auto Selects the cost to use in cost calculations, when the Cost Style parameter is set to RSTP in the Bridge RSTP Parameters configuration. Setting the cost manually provides the ability to preferentially select specific ports to carry traffic over others. Leave this field set to "auto" to use the standard RSTP port costs as negotiated (20,000 for 1Gbps, 200,000 for 100 Mbps links and 2,000,000 for 10 Mbps links). For MSTP, this parameter applies to both external and internal path cost.

Edge Port Synopsis: { False, True, Auto } Default: Auto Edge ports are ports that do not participate in the Spanning Tree, but still send configuration messages. Edge ports transition directly to frame forwarding without any listening and learning delays. The MAC tables of Edge ports do not need to be flushed when topology changes occur in the STP network. Unlike an STP disabled port, accidentally connecting an edge port to another port in the spanning tree will result in a detectable loop. The "Edgeness" of the port will be switched off and the standard RSTP rules will apply (until the next link outage).

Point to Point Synopsis: { False, True, Auto } Default: Auto RSTP uses a peer-to-peer protocol that provides rapid transitioning on point-to-point links. This protocol is automatically turned off in situations where multiple STP bridges communicate over a shared (non point-to-point) LAN. The bridge will automatically take point- to-point to be true when the link is found to be operating in full- duplex mode. The point-to-point parameter allows this behavior or overrides it, forcing point-to-point to be true or false. Force the parameter true when the port operates a point-to-point link but

166 Configuring STP for Specific Ethernet Ports RUGGEDCOM ROS Chapter 5 User Guide Setup and Configuration

Parameter Description cannot run the link in full-duplex mode. Force the parameter false when the port operates the link in full-duplex mode, but is still not point-to-point (e.g. a full-duplex link to an unmanaged bridge that concentrates two other STP bridges).

Restricted Role Synopsis: { True or False } Default: False A boolean value set by management. If TRUE, causes the Port not to be selected as the Root Port for the CIST or any MSTI, even if it has the best spanning tree priority vector. Such a Port will be selected as an Alternate Port after the Root Port has been selected. This parameter should be FALSE by default. If set, it can cause a lack of spanning tree connectivity. It is set by a network administrator to prevent bridges that are external to a core region of the network from influencing the spanning tree active topology. This may be necessary, for example, if those bridges are not under the full control of the administrator.

Restricted TCN Synopsis: { True or False } Default: False A boolean value set by management. If TRUE, it causes the Port not to propagate received topology change notifications and topology changes to other Ports. If set, it can cause temporary loss of connectivity after changes in a spanning tree’s active topology as a result of persistent, incorrectly learned, station location information. It is set by a network administrator to prevent bridges that are external to a core region of the network from causing address flushing in that region. This may be necessary, for example, if those bridges are not under the full control of the administrator or if the MAC_Operational status parameter for the attached LANs transitions frequently.

4. Click Apply.

Section 5.2.6 Configuring eRSTP

To configure eRSTP, do the following: 1. Navigate to Spanning Tree » Configure eRSTP Parameters . The eRSTP Parameters form appears.

1

2

3

4

5 6 7

Figure 97: eRSTP Parameters Form 1. Max Network Diameter Options 2. BPDU Guart Timeout Box 3. Fast Root Failover List 4. IEEE802.1w Interoperability Options 5. Cost Style Options 6. Apply Button 7. Reload Button

Configuring eRSTP 167 Chapter 5 RUGGEDCOM ROS Setup and Configuration User Guide

2. Configure the following parameter(s) as required:

Parameter Description

Max Network Diameter Synopsis: { MaxAgeTime, 4*MaxAgeTime } Default: 4*MaxAgeTime The RSTP standard puts a limit on the maximum network size that can be controlled by the RSTP protocol. The network size is described by the term 'maximum network diameter', which is the number of switches that comprise the longest path that RSTP BPDUs have to traverse. The standard supported maximum network diameter is equal to the value of the 'MaxAgeTime' RSTP configuration parameter. eRSTP offers an enhancement to RSTP which allows it to cover networks larger than ones defined by the standard. This configuration parameter selects the maximum supported network size.

BPDU Guard Timeout Synopsis: 1 to 86400 s or { Until reset, Don't shutdown } Default: Don't shutdown The RSTP standard does not address network security. RSTP must process every received BPDU and take an appropriate action. This opens a way for an attacker to influence RSTP topology by injecting RSTP BPDUs into the network. BPDU Guard is a feature that protects the network from BPDUs received by a port where RSTP capable devices are not expected to be attached. If a BPDU is received by a port for which 'Edge' parameter is set to 'TRUE' or RSTP is disabled, the port will be shutdown for the time period specified by this parameter. • DON'T SHUTDOWN - BPDU Guard is disabled • UNTIL RESET - port will remain shutdown until the port reset command is issued by the user

Fast Root Failover Synopsis: { On, On with standard root, Off } Default: On In mesh network topologies, the standard RSTP algorithm does not guarantee deterministic network recovery time in the case of a root switch failure. Such a recovery time is hard to calculate and it can be different (and may be relatively long) for any given mesh topology. This configuration parameter enables Siemens's enhancement to RSTP which detects a failure of the root switch and performs some extra RSTP processing steps, significantly reducing the network recovery time and making it deterministic.

NOTE • This feature is only available in RSTP mode. In MSTP mode, the configuration parameter is ignored. • In a single ring topology, this feature is not needed and should be disabled to avoid longer network recovery times due to extra RSTP processing.

The Fast Root Failover algorithm must be supported by all switches in the network, including the root, to guarantee optimal performance. However, it is not uncommon to assign the root role to a switch from a vendor different from the rest of the switches in the network. In other words, it is possible that the root might not suport the Fast Root Failover algorithm. In such a scenario, a "relaxed" algorithm should be used, which tolerates the lack of support in the root switch.

168 Configuring eRSTP RUGGEDCOM ROS Chapter 5 User Guide Setup and Configuration

Parameter Description These are the supported configuration options: • Off - Fast Root Failover algorithm is disabled and hence a root switch failure may result in excessive connectivity recovery time. • On - Fast Root Failover is enabled and the most robust algorithm is used, which requires the appropriate support in the root switch. • On with standard root - Fast Root Failover is enabled but a "relaxed" algorithm is used, allowing the use of a standard switch in the root role.

IEEE802.1w Interoperability Synopsis: { On, Off } Default: On The original RSTP protocol defined in the IEEE 802.1w standard has minor differences from more recent, enhanced, standard(s). Those differences cause interoperability issues which, although they do not completely break RSTP operation, can lead to a longer recovery time from failures in the network. eRSTP offers some enhancements to the protocol which make the switch fully interoperable with other vendors' switches, which may be running IEEE 802.2w RSTP. The enhancements do not affect interoperability with more recent RSTP editions. This configuration parameter enables the aforementioned interoperability mode.

Cost Style Synopsis: { STP (16 bit), RSTP (32 bit) } Default: STP (16 bit) The RSTP standard defines two styles of a path cost value. STP uses 16-bit path costs based upon 1x10E9/link speed (4 for 1Gbps, 19 for 100 Mbps and 100 for 10 Mbps) whereas RSTP uses 32-bit costs based upon 2x10E13/link speed (20,000 for 1Gbps, 200,000 for 100 Mbps and 2,000,000 for 10 Mbps). However, switches from some vendors keep using the STP path cost style even in RSTP mode, which can cause confusion and interoperability problems. This configuration parameter selects the style of link costs to employ. Note that RSTP link costs are used only when the bridge version support is set to allow RSTP and the port does not migrate to STP.

3. Click Apply.

Section 5.2.7 Viewing Global Statistics for STP

To view global statistics for STP, navigate to Spanning Tree » View Bridge RSTP Statistics . The Bridge RSTP Statistics form appears.

Viewing Global Statistics for STP 169 Chapter 5 RUGGEDCOM ROS Setup and Configuration User Guide

1

2

3

4

5

6

7

8

9

10

11

12

13

14

Figure 98: Bridge RSTP Statistics Form 1. Bridge Status Box 2. Bridge ID Box 3. Root ID Box 4. Root Port Box 5. Root Path Cost Box 6. Configure Hello Time Box 7. Learned Hello Time Box 8. Configured Forward Delay Box 9. Learned Forward Delay Box 10. Configured Max Age Box 11. Learned Max Age Box 12. Total Topology Changes Box 13. Time Since Last TC Box 14. Reload Button

This table displays the following information:

Parameter Description

Bridge Status Synopsis: { , Designated Bridge, Not Designated For Any LAN, Root Bridge } Spanning Tree status of the bridge. The status may be root or designated. This field may show text saying not designated for any LAN if the bridge is not designated for any of its ports.

Bridge ID Synopsis: $$ / ##-##-##-##-##-## where $$ is 0 to 65535, ## is 0 to FF Bridge Identifier of this bridge.

Root ID Synopsis: $$ / ##-##-##-##-##-## where $$ is 0 to 65535, ## is 0 to FF Bridge Identifier of the root bridge.

Root Port Synopsis: 1 to maximum port number or { } If the bridge is designated, this is the port that provides connectivity towards the root bridge of the network.

Root Path Cost Synopsis: 0 to 4294967295 Total cost of the path to the root bridge composed of the sum of the costs of each link in the path. If custom costs have not been configured. 1Gbps ports will contribute 4, 100 Mbps ports will contribute 19 and 10 Mbps ports will contribute a cost of 100 to this figure. For the CIST instance of MSTP, this is an external root path cost, which is the cost of the path from the IST root (i.e. regional root) bridge to the CST root (i.e. network "global" root) bridge.

Configured Hello Time Synopsis: 0 to 65535 The configured Hello time from the Bridge RSTP Parameters menu.

Learned Hello Time Synopsis: 0 to 65535

170 Viewing Global Statistics for STP RUGGEDCOM ROS Chapter 5 User Guide Setup and Configuration

Parameter Description The actual Hello time provided by the root bridge as learned in configuration messages. This time is used in designated bridges.

Configured Forward Delay Synopsis: 0 to 65535 The configured Forward Delay time from the Bridge RSTP Parameters menu.

Learned Forward Delay Synopsis: 0 to 65535 The actual Forward Delay time provided by the root bridge as learned in configuration messages. This time is used in designated bridges.

Configured Max Age Synopsis: 0 to 65535 The configured Maximum Age time from the Bridge RSTP Parameters menu.

Learned Max Age Synopsis: 0 to 65535 The actual Maximum Age time provided by the root bridge as learned in configuration messages. This time is used in designated bridges.

Total Topology Changes Synopsis: 0 to 65535 A count of topology changes in the network, as detected on this bridge through link failures or as signaled from other bridges. Excessively high or rapidly increasing counts signal network problems.

Time since Last TC Synopsis: DDDD days, HH:MM:SS The time since the last time a topology change was detected by the bridge.

Section 5.2.8 Viewing STP Statistics for Ethernet Ports

To view STP statistics for Ethernet ports, navigate to Spanning Tree » View Port RSTP Statistics . The Port RSTP Statistics table appears.

Figure 99: Port RSTP Statistics Table

Viewing STP Statistics for Ethernet Ports 171 Chapter 5 RUGGEDCOM ROS Setup and Configuration User Guide

This table displays the following information:

Parameter Description

Port(s) Synopsis: Any combination of numbers valid for this parameter The port number as seen on the front plate silkscreen of the switch (or a list of ports, if aggregated in a port trunk).

Status Synopsis: { Disabled, Listening, Learning, Forwarding, Blocking, Link Down, Discarding } Status of this port in Spanning Tree. This may be one of the following: • Disabled - STP is disabled on this port. • Link Down - STP is enabled on this port but the link is down. • Discarding - The link is not used in the STP topology but is standing by. • Learning - The port is learning MAC addresses in order to prevent flooding when it begins forwarding traffic. • Forwarding - The port is forwarding traffic.

Role Synopsis: { , Root, Designated, Alternate, Backup, Master } Role of this port in Spanning Tree. This may be one of the following: • Designated - The port is designated for (i.e. carries traffic towards the root for) the LAN it is connected to. • Root - The single port on the bridge, which provides connectivity towards the root bridge. • Backup - The port is attached to a LAN that is serviced by another port on the bridge. It is not used but is standing by. • Alternate - The port is attached to a bridge that provides connectivity to the root bridge. It is not used but is standing by. • Master - Only exists in MSTP. The port is an MST region boundary port and the single port on the bridge, which provides connectivity for the Multiple Spanning Tree Instance towards the Common Spanning Tree root bridge (i.e. this port is the root port for the Common Spanning Tree Instance).

Cost Synopsis: 0 to 4294967295 Cost offered by this port. If the Bridge RSTP Parameters Cost Style is set to STP, 1Gbps ports will contribute 4, 100 Mbps ports will contribute 19 and 10 Mbps ports contribute a cost of 100. If the Cost Style is set to RSTP, 1Gbps will contribute 20,000, 100 Mbps ports will contribute a cost of 200,000 and 10 Mbps ports contribute a cost of 2,000,000. Note that even if the Cost style is set to RSTP, a port that migrates to STP will have its cost limited to a maximum of 65535.

RX RSTs Synopsis: 0 to 4294967295 The count of RSTP configuration messages received on this port.

TX RSTs Synopsis: 0 to 4294967295 The count of RSTP configuration messages transmitted on this port.

RX Configs Synopsis: 0 to 4294967295 The count of STP configuration messages received on this port.

TX Configs Synopsis: 0 to 4294967295 The count of STP configuration messages transmitted on this port.

RX Tcns Synopsis: 0 to 4294967295

172 Viewing STP Statistics for Ethernet Ports RUGGEDCOM ROS Chapter 5 User Guide Setup and Configuration

Parameter Description The count of STP topology change notification messages received on this port. Excessively high or rapidly increasing counts signal network problems.

TX Tcns Synopsis: 0 to 4294967295 The count of STP topology change notification messages transmitted on this port.

Desig Bridge ID Synopsis: $$ / ##-##-##-##-##-## where $$ is 0 to 65535, ## is 0 to FF Provided on the root ports of designated bridges, the Bridge Identifier of the bridge this port is connected to.

operEdge Synopsis: True or False The port is operating as an edge port or not.

Section 5.2.9 Managing Multiple Spanning Tree Instances

The following section describes how to configure and manage Multiple Spanning Tree Instances.

CONTENTS • Section 5.2.9.1, “Viewing Statistics for Global MSTIs” • Section 5.2.9.2, “Viewing Statistics for Port MSTIs” • Section 5.2.9.3, “Configuring the MST Region Identifier” • Section 5.2.9.4, “Configuring a Global MSTI” • Section 5.2.9.5, “Configuring an MSTI for an Ethernet Port”

Section 5.2.9.1 Viewing Statistics for Global MSTIs

To view statistics for global MSTIs, navigate to Spanning Tree » View Bridge MSTI Statistics . The Bridge MSTI Statistics form appears.

Managing Multiple Spanning Tree Instances 173 Chapter 5 RUGGEDCOM ROS Setup and Configuration User Guide

1 2

3

4

5

6

7

8

9

Figure 100: Bridge MSTI Statistics Form 1. Instance Box 2. Get Button 3. Bridge Status Box 4. Bridge ID Box 5. Root ID Box 6. Root Port Box 7. Root Path Cost Box 8. Total Topology Changes Box 9. Reload Button

This table displays the following information:

Parameter Description

Bridge Status Synopsis: { , Designated Bridge, Not Designated For Any LAN, Root Bridge } Spanning Tree status of the bridge. The status may be root or designated. This field may show text saying not designated for any LAN if the bridge is not designated for any of its ports.

Bridge ID Synopsis: $$ / ##-##-##-##-##-## where $$ is 0 to 65535, ## is 0 to FF Bridge Identifier of this bridge.

Root ID Synopsis: $$ / ##-##-##-##-##-## where $$ is 0 to 65535, ## is 0 to FF Bridge Identifier of the root bridge.

Root Port Synopsis: 1 to maximum port number or { } If the bridge is designated, this is the port that provides connectivity towards the root bridge of the network.

Root Path Cost Synopsis: 0 to 4294967295 Total cost of the path to the root bridge composed of the sum of the costs of each link in the path. If custom costs have not been configured. 1Gbps ports will contribute 4, 100 Mbps ports will contribute 19 and 10 Mbps ports will contribute a cost of 100 to this figure. For the CIST instance of MSTP, this is an external root path cost, which is the cost of the path from the IST root (i.e. regional root) bridge to the CST root (i.e. network "global" root) bridge.

Total Topology Changes Synopsis: 0 to 65535 A count of topology changes in the network, as detected on this bridge through link failures or as signaled from other bridges.

174 Viewing Statistics for Global MSTIs RUGGEDCOM ROS Chapter 5 User Guide Setup and Configuration

Parameter Description Excessively high or rapidly increasing counts signal network problems.

Section 5.2.9.2 Viewing Statistics for Port MSTIs

To view statistics for port MSTIs, navigate to Spanning Tree » View Port MSTI Statistics . The Port MSTI Statistics form appears.

1 2

Figure 101: Port MSTI Statistics Form 1. Instance ID Box 2. Get Button

This table displays the following information:

Parameter Description

Port(s) Synopsis: Any combination of numbers valid for this parameter The port number as seen on the front plate silkscreen of the switch (or a list of ports, if aggregated in a port trunk).

Status Synopsis: { Disabled, Listening, Learning, Forwarding, Blocking, Link Down, Discarding } tatus of this port in Spanning Tree. This may be one of the following: • Disabled - STP is disabled on this port. • Link Down - STP is enabled on this port but the link is down. • Discarding - The link is not used in the STP topology but is standing by. • Learning - The port is learning MAC addresses in order to prevent flooding when it begins forwarding traffic. • Forwarding - The port is forwarding traffic.

Role Synopsis: { , Root, Designated, Alternate, Backup, Master }

Viewing Statistics for Port MSTIs 175 Chapter 5 RUGGEDCOM ROS Setup and Configuration User Guide

Parameter Description Role of this port in Spanning Tree. This may be one of the following: • Designated - The port is designated for (i.e. carries traffic towards the root for) the LAN it is connected to. • Root - The single port on the bridge, which provides connectivity towards the root bridge. • Backup - The port is attached to a LAN that is serviced by another port on the bridge. It is not used but is standing by. • Alternate - The port is attached to a bridge that provides connectivity to the root bridge. It is not used but is standing by. • Master - Only exists in MSTP. The port is an MST region boundary port and the single port on the bridge, which provides connectivity for the Multiple Spanning Tree Instance towards the Common Spanning Tree root bridge (i.e. this port is the root port for the Common Spanning Tree Instance).

Cost Synopsis: 0 to 4294967295 Cost offered by this port. If the Bridge RSTP Parameters Cost Style is set to STP, 1Gbps ports will contribute 4, 100 Mbps ports will contribute 19 and 10 Mbps ports contribute a cost of 100. If the Cost Style is set to RSTP, 1Gbps will contribute 20,000, 100 Mbps ports will contribute a cost of 200,000 and 10 Mbps ports contribute a cost of 2,000,000. Note that even if the Cost style is set to RSTP, a port that migrates to STP will have its cost limited to a maximum of 65535.

Desig Bridge ID Synopsis: $$ / ##-##-##-##-##-## where $$ is 0 to 65535, ## is 0 to FF Provided on the root ports of designated bridges, the Bridge Identifier of the bridge this port is connected to.

Section 5.2.9.3 Configuring the MST Region Identifier

Configuring the region identifier and revision level puts the MSTP bridge in a defined group. Other bridges that have the same identifier and revision level are interconnected within this region. For more information, refer to Section 5.2.3.1, “MSTP Regions and Interoperability” . To configure the Multiple Spanning Tree (MST) region identifier, do the following: 1. Navigate to Spanning Tree » Configure MST Region Identifier . The MST Region Identifier form appears.

1

2

3

4 5

Figure 102: MST Region Identifier Form 1. Name Box 2. Revision Level Box 3. Digest Box 4. Apply Button 5. Reload Button

176 Configuring the MST Region Identifier RUGGEDCOM ROS Chapter 5 User Guide Setup and Configuration

2. Configure the following parameter(s) as required:

Parameter Description

Name Synopsis: Any 32 characters Default: 00-0A-DC-92-00-00 The name of the MST region. All devices in the same MST region must have the same region name configured.

Revision Level Synopsis: 0 to 65535 Default: 0 The revision level for MST configuration. Typically, all devices in the same MST region are configured with the same revision level. However, different revision levels can be used to create sub- regions under the same region name.

Digest Synopsis: Any 32 characters Default: 0 This is a read-only parameter and should be only used for network troubleshooting. In order to ensure consistent VLAN-to-instance mapping, it is necessary for the protocol to be able to exactly identify the boundaries of the MST regions. For that pupose, the characteristics of the region are included in BPDUs. There is no need to propagate the exact VLAN-to-instance mapping in the BPDUs because switches only need to know whether they are in the same region as a neighbor. Therefore, only this 16-octet digest created from the VLAN-to-instance mapping is sent in BPDUs.

3. Click Apply.

Section 5.2.9.4 Configuring a Global MSTI

To configure a global Multiple Spanning Tree Instance (MSTI) for the Spanning Tree Protocol (STP), do the following: 1. Navigate to Spanning Tree » Configure Bridge MSTI Parameters . The Bridge MSTI Parameters form appears.

1 2

3

4 5

Figure 103: Bridge MSTI Parameters Form 1. Instance ID Box 2. Get Button 3. Bridge Priority List 4. Apply Button 5. Reload Button

Configuring a Global MSTI 177 Chapter 5 RUGGEDCOM ROS Setup and Configuration User Guide

2. Under Instance ID, type an ID number for a Multiple Spanning Tree Instance (MSTI) and click GET. The settings for the MSTI are displayed. Any changes made to the configuration will be applied specifically to this instance ID. 3. Configure the following parameter(s) as required:

Parameter Description

Bridge Priority Synopsis: { 0, 4096, 8192, 12288, 16384, 20480, 24576, 28672, 32768, 36864, 40960, 45056, 49152, 53248, 57344, 61440 } Default: 32768 Bridge Priority provides a way to control the topology of the STP connected network. The desired Root and Designated bridges can be configured for a particular topology. The bridge with the lowest priority will become root. In the event of a failure of the root bridge, the bridge with the next lowest priority will then become root. Designated bridges that (for redundancy purposes) service a common LAN also use priority to determine which bridge is active. In this way careful selection of Bridge Priorities can establish the path of traffic flows in normal and abnormal conditions.

4. Click Apply.

Section 5.2.9.5 Configuring an MSTI for an Ethernet Port

To configure a Multiple Spanning Tree Instance (MSTI) for an Ethernet port, do the following 1. Navigate to Spanning Tree » Configure Port MSTI Parameters . The Port MSTI Parameters table appears.

Figure 104: Port MSTI Parameters Table

2. Select an Ethernet port. The Port MSTI Parameters form appears.

178 Configuring an MSTI for an Ethernet Port RUGGEDCOM ROS Chapter 5 User Guide Setup and Configuration

1 2

3

4

5

6

7 8

Figure 105: Port MSTI Parameters Form 1. Instance ID Box 2. Get Button 3. Port(s) Box 4. Priority List 5. STP Cost Box 6. RSTP Cost Box 7. Apply Button 8. Reload Button

3. Under Instance ID, type an ID number for a Multiple Spanning Tree Instance (MSTI) and click GET. The settings for the MSTI are displayed. Any changes made to the configuration will be applied specifically to this instance ID. 4. Configure the following parameter(s) as required:

Parameter Description

Port(s) Synopsis: Any combination of numbers valid for this parameter The port number as seen on the front plate silkscreen of the switch (or a list of ports, if aggregated in a port trunk).

Priority Synopsis: { 0, 16, 32, 48, 64, 80, 96, 112, 128, 144, 160, 176, 192, 208, 224, 240 } Default: 128 Selects the STP port priority. Ports of the same cost that attach to a common LAN will select the port to be used based upon the port priority.

STP Cost Synopsis: 0 to 65535 or { Auto } Default: Auto Selects the cost to use in cost calculations, when the Cost Style parameter is set to STP in the Bridge RSTP Parameters configuration. Setting the cost manually provides the ability to preferentially select specific ports to carry traffic over others. Leave this field set to "auto" to use the standard STP port costs as negotiated (4 for 1Gbps, 19 for 100 Mbps links and 100 for 10 Mbps links). For MSTP, this parameter applies to both external and internal path cost.

RSTP Cost Synopsis: 0 to 2147483647 or { Auto } Default: Auto Selects the cost to use in cost calculations, when the Cost Style parameter is set to RSTP in the Bridge RSTP Parameters configuration. Setting the cost manually provides the ability to preferentially select specific ports to carry traffic over others. Leave this field set to "auto" to use the standard RSTP port costs

Configuring an MSTI for an Ethernet Port 179 Chapter 5 RUGGEDCOM ROS Setup and Configuration User Guide

Parameter Description as negotiated (20,000 for 1Gbps, 200,000 for 100 Mbps links and 2,000,000 for 10 Mbps links). For MSTP, this parameter applies to both external and internal path cost.

5. Click Apply.

Section 5.2.10 Clearing Spanning Tree Protocol Statistics

To clear all spanning tree protocol statistics, do the following: 1. Navigate to Spanning Tree » Clear Spanning Tree Statistics . The Clear Spanning Tree Statistics form appears.

1

Figure 106: Clear Spanning Tree Statistics Form 1. Confirm Button

2. Click Confirm.

Section 5.3 Managing Classes of Service

Classes of Service (CoS) provides the ability to expedite the transmission of certain frames and port traffic over others. The CoS of a frame can be set to Normal, Medium, High, or Critical. By default, other than the control frames, RUGGEDCOM ROS enforces Normal CoS for all incoming traffic received without a priority tag.

IMPORTANT! Use the highest supported CoS with caution, as it is always used by the switch for handling network management traffic, such as RSTP BPDUs. If this CoS is used for regular network traffic, upon traffic bursts, it may result in the loss of some network management frames, which in turn may result in the loss of connectivity over the network.

The process of controlling traffic based on CoS occurs over two phases: 1. Inspection Phase In the inspection phase, the CoS priority of a received frame is determined from either: • A specific CoS based upon the source and destination MAC address (as set in the Static MAC Address Table) • The priority field in the IEEE 802.1Q tags

180 Clearing Spanning Tree Protocol Statistics RUGGEDCOM ROS Chapter 5 User Guide Setup and Configuration

• The Differentiated Services Code Point (DSCP) component of the Type Of Service (TOS) field in the IP header, if the frame is IP • The default CoS for the port Each frame’s CoS will be determined once the first examined parameter is found in the frame.

NOTE For information on how to configure the Inspect TOS parameter, refer to Section 5.3.2, “Configuring Classes of Service for Specific Ethernet Ports” .

Received frames are first examined to determine if their destination or source MAC address is found in the Static MAC Address Table. If they are, the CoS configured for the static MAC address is used. If neither destination or source MAC address is in the Static MAC Address Table, the frame is then examined for IEEE 802.1Q tags and the priority field is mapped to a CoS. If a tag is not present, the frame is examined to determine if it is an IP frame. If the frame is an IP frame and Inspect TOS is enabled in RUGGEDCOM ROS, the CoS is determined from the DSCP field. If the frame is not an IP frame or Inspect TOS is disabled, the default CoS for the port is used. After inspection, the frame is forwarded to the egress port for transmission. 2. Forwarding Phase Once the CoS of the frame is determined, the frame is forwarded to the egress port, where it is collected into one of the priority queues according to the assigned CoS. CoS weighting selects the degree of preferential treatment that is attached to different priority queues. The ratio of the number of higher CoS to lower CoS frames transmitted can be configured. If desired, lower CoS frames can be transmitted only after all higher CoS frames have been serviced.

CONTENTS • Section 5.3.1, “Configuring Classes of Service Globally” • Section 5.3.2, “Configuring Classes of Service for Specific Ethernet Ports” • Section 5.3.3, “Configuring Priority to CoS Mapping” • Section 5.3.4, “Configuring DSCP to CoS Mapping”

Section 5.3.1 Configuring Classes of Service Globally

To configure global settings for Classes of Service (CoS), do the following: 1. Navigate to Classes of Service » Configure Global CoS Parameters . The Global CoS Parameters form appears.

Configuring Classes of Service Globally 181 Chapter 5 RUGGEDCOM ROS Setup and Configuration User Guide

1

2 3

Figure 107: Global CoS Parameters Form 1. CoS Weighting Options 2. Apply Button 3. Reload Button

2. Configure the following parameter(s) as required:

Parameter Description

CoS Weighting Synopsis: { 8:4:2:1, Strict } Default: 8:4:2:1 During traffic bursts, frames queued in the switch pending transmission on a port may have different CoS priorities. This parameter specifies weighting algorithm for transmitting different priority CoS frames. Examples: • 8:4:2:1 - 8 Critical, 4 High, 2 Medium and 1 Normal priority CoS frame • Strict - lower priority CoS frames will be only transmitted after all higher priority CoS frames have been transmitted

3. Click Apply. 4. If necessary, configure CoS mapping based on either the IEEE 802.1p priority or Differentiated Services (DS) field set in the IP header for each packet. For more information, refer to Section 5.3.3, “Configuring Priority to CoS Mapping” or Section 5.3.4, “Configuring DSCP to CoS Mapping” .

Section 5.3.2 Configuring Classes of Service for Specific Ethernet Ports

To configure Classes of Service (CoS) for one or more Ethernet ports, do the following: 1. Navigate to Classes of Service » Configure Port CoS Parameters . The Port CoS Parameters table appears.

182 Configuring Classes of Service for Specific Ethernet Ports RUGGEDCOM ROS Chapter 5 User Guide Setup and Configuration

Figure 108: Port CoS Parameters Table

2. Select an Ethernet port. The Port CoS Parameters form appears.

1

2

3

4 5

Figure 109: Port CoS Parameters Form 1. Port(s) Box 2. Default Pri Box 3. Inspect TOS Options 4. Apply Button 5. Reload Button

3. Configure the following parameter(s) as required:

Parameter Description

Port(s) Synopsis: Any combination of numbers valid for this parameter The port number as seen on the front plate silkscreen of the switch (or a list of ports, if aggregated in a port trunk).

Default Pri Synopsis: 0 to 7 Default: 0 This parameter allows to prioritize frames received on this port that are not prioritized based on the frames contents (e.g. priority field in the VLAN tag, DiffServ field in the IP header, prioritized MAC address).

Inspect TOS Synopsis: { No, Yes } Default: No This parameters enables or disables parsing of the Type-Of-Service (TOS) field in the IP header of the received frames to determine what Class of Service they should be assigned. When TOS parsing

Configuring Classes of Service for Specific Ethernet Ports 183 Chapter 5 RUGGEDCOM ROS Setup and Configuration User Guide

Parameter Description is enabled the switch will use the Differentiated Services bits in the TOS field.

4. Click Apply.

Section 5.3.3 Configuring Priority to CoS Mapping

Frames received untagged can be automatically assigned a CoS based on their priority level. To map a priority level to a CoS, do the following: 1. Navigate to Classes of Service » Configure Priority to CoS Mapping . The Priority to CoS Mapping table appears.

Figure 110: Priority to CoS Mapping Table

2. Select a priority level. The Priority to CoS Mapping form appears.

1

2

3 4

Figure 111: Priority to CoS Mapping Form 1. Priority Box 2. CoS List 3. Apply Button 4. Reload Button

3. Configure the following parameter(s) as required:

Parameter Description

Priority Synopsis: 0 to 7 Default: 0

184 Configuring Priority to CoS Mapping RUGGEDCOM ROS Chapter 5 User Guide Setup and Configuration

Parameter Description Value of the IEEE 802.1p priority.

CoS Synopsis: { Normal, Medium, High, Crit } Default: Normal CoS assigned to received tagged frames with the specified IEEE 802.1p priority value.

4. Click Apply.

Section 5.3.4 Configuring DSCP to CoS Mapping

Mapping CoS to the Differentiated Services (DS) field set in the IP header for each packet is done by defining Differentiated Services Code Points (DSCPs) in the CoS configuration. To map a DSCP to a Class of Service, do the following: 1. Navigate to Classes of Service » Configure DSCP to CoS Mapping . The DSCP to CoS Mapping table appears.

Figure 112: DSCP to CoS Mapping Table

2. Select a DSCP level. The DSCP to CoS Mapping form appears.

Configuring DSCP to CoS Mapping 185 Chapter 5 RUGGEDCOM ROS Setup and Configuration User Guide

1

2

3 4

Figure 113: DSCP to CoS Mapping Form 1. DSCP Box 2. CoS List 3. Apply Button 4. Reload Button

3. Configure the following parameter(s) as required:

Parameter Description

DSCP Synopsis: 0 to 63 Default: 0 Differentiated Services Code Point (DSCP) - a value of the 6 bit DiffServ field in the Type-Of-Service (TOS) field of the IP header.

CoS Synopsis: { Normal, Medium, High, Crit } Default: Normal Class of Service assigned to received frames with the specified DSCP.

4. Click Apply. 5. Configure the CoS parameters on select switched Ethernet ports as needed. For more information, refer to Section 5.3.2, “Configuring Classes of Service for Specific Ethernet Ports” .

Section 5.4 Managing MAC Addresses

The following section describes how to configure and manage MAC addresses.

CONTENTS • Section 5.4.1, “Viewing a List of MAC Addresses” • Section 5.4.2, “Configuring MAC Address Learning Options” • Section 5.4.3, “Configuring MAC Address Flooding Options” • Section 5.4.4, “Managing Static MAC Addresses”

186 Managing MAC Addresses RUGGEDCOM ROS Chapter 5 User Guide Setup and Configuration

• Section 5.4.5, “Purging All Dynamic MAC Addresses”

Section 5.4.1 Viewing a List of MAC Addresses

To view a list of all static and dynamically learned MAC addresses, navigate to MAC Address Tables » View MAC Addresses . The MAC Addresses table appears.

Figure 114: MAC Address Table

If a MAC address is not listed, do the following: • Configure the MAC address learning options to control the aging time of dynamically learned MAC addresses of other devices on the network. For more information, refer to Section 5.4.2, “Configuring MAC Address Learning Options” . • Configure the address on the device as a static MAC address. For more information, refer to Section 5.4.4.2, “Adding a Static MAC Address” .

Viewing a List of MAC Addresses 187 Chapter 5 RUGGEDCOM ROS Setup and Configuration User Guide

Section 5.4.2 Configuring MAC Address Learning Options

The MAC address learning options control how and when MAC addresses are removed automatically from the MAC address table. Individual addressees are removed when the aging timer is exceeded. Addresses can also be removed when a link failure or topology change occurs. To configure the MAC address learning options, do the following: 1. Navigate to MAC Address Tables » Configure MAC Address Learning Options . The MAC Address Learning Options form appears.

1

2

3 4

Figure 115: MAC Address Learning Options Form 1. Aging Time Box 2. Age Upon Link Loss Options 3. Apply Button 4. Reload Button

2. Configure the following parameter(s) as required:

Parameter Description

Aging Time Synopsis: 15 to 800 Default: 300 s This parameter configures the time that a learned MAC address is held before being aged out.

Age Upon Link Loss Synopsis: { No, Yes } Default: Yes When set to Yes, all MAC addresses learned on a failed port will be aged-out immediately upon link failure detection. When link failure occurs the switch may have some MAC addresses previously learned on the failed port. As long as those addresses are not aged-out the switch will still be forwarding traffic to that port, thus preventing that traffic from reaching its destination via the new network topology. Note that when a network redundancy protocol, e.g. RSTP/MSTP, is enabled on the switch, that redundancy protocol may, upon a link failure, flush MAC addresses learned on the failed port regardless of the setting of this parameter.

3. Click Apply.

Section 5.4.3 Configuring MAC Address Flooding Options

To configure the MAC address flooding options, do the following:

188 Configuring MAC Address Learning Options RUGGEDCOM ROS Chapter 5 User Guide Setup and Configuration

1. Navigate to MAC Address Tables » Configure MAC Address Flooding Options . The Flooding Options table appears.

Figure 116: Flooding Options Table

2. Select a port. The Flooding Options form appears.

1

2

3 4

Figure 117: Flooding Options Form 1. Port(s) Box 2. Flood Unknown Unicast Options 3. Apply Button 4. Reload Button

3. Configure the following parameter(s) as required:

Parameter Description

Port(s) Synopsis: Comma-separated list of ports The port number as seen on the front plate silkscreen of the switch (or a list of ports, if aggregated in a port trunk).

Flood Unknown Unicast Synopsis: { On, Off } Default: On Normally, unicast traffic with an unknown destination address is flooded out of all ports. When a port is configured to turn off this kind of flooding, the unknown unicast traffic is not sent out from the selected port.

4. Click Apply.

Configuring MAC Address Flooding Options 189 Chapter 5 RUGGEDCOM ROS Setup and Configuration User Guide

Section 5.4.4 Managing Static MAC Addresses

Static MAC addresses must be configured when the device is only able to receive frames, not transmit them. They may also need to be configured if port security (if supported) must be enforced. Prioritized MAC addresses are configured when traffic to or from a specific device on a LAN segment is to be assigned a higher CoS priority than other devices on that LAN segment.

NOTE A MAC address cannot be learned on a VLAN that has not been configured in the Static VLAN table. If a frame with an unknown VLAN tag arrives on a secured port, it is considered a security violation and ROS will generate a port security alarm.

CONTENTS • Section 5.4.4.1, “Viewing a List of Static MAC Addresses” • Section 5.4.4.2, “Adding a Static MAC Address” • Section 5.4.4.3, “Deleting a Static MAC Address”

Section 5.4.4.1 Viewing a List of Static MAC Addresses

To view a list of static MAC addresses configured on the device, navigate to MAC Address Tables » Configure Static MAC Addresses . The Static MAC Addresses table appears.

Figure 118: Static MAC Address Table

If static MAC addresses have not been configured, add addresses as needed. For more information, refer to Section 5.4.4.2, “Adding a Static MAC Address” .

Section 5.4.4.2 Adding a Static MAC Address

To add a static MAC address to the Static MAC Address Table, do the following: 1. Navigate to MAC Address Tables » Configure Static MAC Addresses . The Static MAC Addresses table appears.

190 Managing Static MAC Addresses RUGGEDCOM ROS Chapter 5 User Guide Setup and Configuration

1

Figure 119: Static MAC Addresses Table 1. InsertRecord

2. Click InsertRecord. The Static MAC Addresses form appears.

1

2

3

4

5 7

6

Figure 120: Static MAC Addresses Form 1. MAC Address Box 2. VID Box 3. Port Box 4. CoS List 5. Apply Button 6. Delete Button 7. Reload Button

3. Configure the following parameter(s) as required:

Parameter Description

MAC Address Synopsis: ##-##-##-##-##-## where ## ranges 0 to FF A MAC address learned by the switch. Maximum of 6 wildcard characters may be used to specify a range of MAC addresses allowed to be learned by the Port Security module (when Port Security is set to 'Static MAC' mode). Wildcard must start from the right hand end and continuous. Examples: • 00-0A-DC-**-**-** means the entire MAC address space of RuggedCom. • 00-0A-DC-12-3*-** means the range 00-0A-DC-12-30-00 to 00-0A-DC-12-3F-FF.

VID Synopsis: 1 to 4094 or { ANY } Default: 1

Adding a Static MAC Address 191 Chapter 5 RUGGEDCOM ROS Setup and Configuration User Guide

Parameter Description VLAN Identifier of the VLAN upon which the MAC address operates. Option ANY allows learning a MAC address through the Port Security module on any VLAN's that are configured on the switch.

Port Synopsis: 1 to maximum port number or { Learn } Default: Learn Enter the port number upon which the device with this address is located. The security mode of the port being selected should not be '802.1X'. If the port should be auto-learned, set this parameter to 'Learn'. The option 'Learn' is applicable for Port Security in 'Static MAC' mode.

CoS Synopsis: { N/A, Normal, Medium, High, Crit } Default: N/A Prioritizes traffic for the specified MAC address. To not prioritize traffic based on the address, select N/A.

4. Click Apply.

Section 5.4.4.3 Deleting a Static MAC Address

To delete a static MAC address from the Static MAC Address Table, do the following: 1. Navigate to MAC Address Tables » Configure Static MAC Addresses . The Static MAC Addresses table appears.

Figure 121: Static MAC Addresses Table

2. Select the MAC address from the table. The Static MAC Addresses form appears.

192 Deleting a Static MAC Address RUGGEDCOM ROS Chapter 5 User Guide Setup and Configuration

1

2

3

4

5 7

6

Figure 122: Static MAC Addresses Form 1. MAC Address Box 2. VID Box 3. Port Box 4. CoS List 5. Apply Button 6. Delete Button 7. Reload Button

3. Click Delete.

Section 5.4.5 Purging All Dynamic MAC Addresses

To purge the dynamic MAC address list of all entries, do the following: 1. Navigate to MAC Address Tables » Purge MAC Address Table . The Purge MAC Address Table form appears.

1

Figure 123: Purge MAC Address Table Form 1. Confirm Button

2. Click Confirm.

Section 5.5 Managing Time Services

The System Time Manager offers the following time-keeping and time synchronization features: • Local hardware time keeping and time zone management

Purging All Dynamic MAC Addresses 193 Chapter 5 RUGGEDCOM ROS Setup and Configuration User Guide

• SNTP (Simple Network Time Protocol) client and server

CONTENTS • Section 5.5.1, “Configuring the Time and Date” • Section 5.5.2, “Managing NTP”

Section 5.5.1 Configuring the Time and Date

To set the time, date and other time-keeping related parameters, do the following: 1. Navigate to Administration » System Time Manager » Configure Time and Date . The Time and Date form appears.

1

2

3

4

5

6 7

Figure 124: Time and Date Form 1. Time 2. Date 3. Time Zone 4. DST Offset 5. DST Rule 6. Apply Button 7. Reload Button

2. Configure the following parameter(s) as required:

Parameter Description

Time Synopsis: HH:MM:SS This parameter allows for both the viewing and setting of the local time.

Date Synopsis: MMM DD, YYYY This parameter allows for both the viewing and setting of the local date.

Time Zone Synopsis: { UTC-12:00 (Eniwetok, Kwajalein), UTC-11:00 (Midway Island, Samoa), UTC-10:00 (Hawaii), UTC-9:00 (Alaska), UTC-8:00 (Los Angeles, Vancouver), UTC-7:00 (Calgary, Denver), UTC-6:00 (Chicago, Mexico City), UTC-5:00 (New York, Toronto), UTC-4:30 (Caracas), UTC-4:00 (Santiago), UTC-3:30 (Newfoundland), UTC-3:00 (Brasilia, Buenos Aires), UTC-2:00 (Mid Atlantic), UTC-1:00 (Azores), UTC-0:00 (Lisbon, London), UTC+1:00 (Berlin, Paris, Rome), UTC+2:00 (Athens, Cairo, Helsinki), ... } Default: UTC-5:00 (New York, Toronto)

194 Configuring the Time and Date RUGGEDCOM ROS Chapter 5 User Guide Setup and Configuration

Parameter Description This setting allows for the conversion of UTC (Universal Coordinated Time) to local time.

DST Offset Synopsis: HH:MM:SS Default: 00:00:00 This parameter specifies the amount of time to be shifted forward/backward when DST begins and ends. For example for most part of USA and Canada, DST time shift is 1 hour (01:00:00) forward when DST begins and 1 hour backward when DST ends.

DST Rule Synopsis: mm.n.d/HH:MM:SS mm.n.d/HH:MM:SS This parameter specifies a rule for time and date when the transition between Standard and Daylight Saving Time occurs. • mm - Month of the year (01 - January, 12 - December) • n - nth d-day in the month (1 - 1st d-day, 5 - 5th/last d-day) • d - day of the week (0 - Sunday, 6 - Saturday) • HH - hour of the day (0 - 24) • MM - minute of the hour (0 - 59) • SS - second of the minute (0 - 59) Example: The following rule applies in most part of USA and Canada:

03.2.0/02:00:00 11.1.0/02:00:00

DST begins on March's 2nd Sunday at 2:00am. DST ends on November's 1st Sunday at 2:00am.

Section 5.5.2 Managing NTP

RUGGEDCOM ROS may be configured to refer periodically to a specified NTP server to correct any accumulated drift in the on-board clock. RUGGEDCOM ROS will also serve time via the Simple Network Time Protocol (SNTP) to hosts that request it. Two NTP servers (primary and backup) may be configured for the device. The primary server is contacted first for each attempt to update the system time. If the primary server fails to respond, the backup server is contacted. If either the primary or backup server fails to respond, an alarm is raised.

CONTENTS • Section 5.5.2.1, “Enabling/Disabling NTP Service” • Section 5.5.2.2, “Configuring NTP Servers”

Section 5.5.2.1 Enabling/Disabling NTP Service

To enable or disable NTP Service, do the following:

Managing NTP 195 Chapter 5 RUGGEDCOM ROS Setup and Configuration User Guide

1. NOTE If the device is running as an NTP server, NTP service must be enabled.

Navigate to Administration » System Time Manager » Configure NTP » Configure NTP Service . The SNTP Parameters form appears.

1

2 3

Figure 125: SNTP Parameters Form 1. SNTP Options 2. Apply Button 3. Reload Button

2. Select Enabled to enable SNTP, or select Disabled to disable SNTP. 3. Click Apply.

Section 5.5.2.2 Configuring NTP Servers

To configure either the primary or backup NTP server, do the following: 1. Navigate to Administration » System Time Manager » Configure NTP » Configure NTP Servers . The NTP Servers table appears.

Figure 126: NTP Servers Table

2. Select either Primary or Backup. The NTP Servers form appears.

196 Configuring NTP Servers RUGGEDCOM ROS Chapter 5 User Guide Setup and Configuration

1

2

3

4 5

Figure 127: NTP Servers Form 1. Server Box 2. IP Address Box 3. Update Period Box 4. Apply Button 5. Reload Button

3. Configure the following parameter(s) as required:

Parameter Description

Server Synopsis: Any 8 characters Default: Primary This field tells whether this configuration is for a Primary or a Backup Server.

IP Address Synopsis: ###.###.###.### where ### ranges from 0 to 255 The Server IP Address.

Update Period Synopsis: 1 to 1440 min Default: 60 min Determines how frequently the (S)NTP server is polled for a time update.If the server cannot be reached in three attempts that are made at one minute intervals an alarm is generated.

4. Click Apply.

Section 5.6 Managing SNMP

RUGGEDCOM ROS supports versions 1, 2 and 3 of the Simple Network Management Protocol (SNMP), otherwise referred to as SNMPv1, SNMPv2c and SNMPv3 respectively. SNMPv3 provides secure access to the devices through a combination of authentication and packet encryption over the network. Security features for this protocol include:

Feature Description

Message Integrity Makes sure that a packet has not been tampered with in-transit.

Authentication Determines if the message is from a valid source.

Encryption Encrypts the contents of a packet to prevent it from being seen by an unauthorized source.

SNMPv3 provides security models and security levels. A security model is an authentication strategy setup for a user and the group in which the user resides. A security level is a permitted level of security within a security

Managing SNMP 197 Chapter 5 RUGGEDCOM ROS Setup and Configuration User Guide

model. A combination of a security model and level will determine which security mechanism is employed when handling an SNMP packet. Before configuring SNMPv3, note the following: • Each user belongs to a group • A group defines the access policy for a set of users • An access policy defines what SNMP objects can be accessed for (i.e. reading, writing and creating notifications) • A group determines the list of notifications its users can receive • A group also defines the security model and security level for its users For SNMPv1 and SNMPv2c, a community string can be configured. The string is mapped to the group and access level with a security name, which is configured as User Name.

CONTENTS • Section 5.6.1, “Managing SNMP Users” • Section 5.6.2, “Managing Security-to-Group Mapping” • Section 5.6.3, “Managing SNMP Groups”

Section 5.6.1 Managing SNMP Users

The following section describes how to configure and manage SNMP users.

CONTENTS • Section 5.6.1.1, “Viewing a List of SNMP Users” • Section 5.6.1.2, “Adding an SNMP User” • Section 5.6.1.3, “Deleting an SNMP User”

Section 5.6.1.1 Viewing a List of SNMP Users

To view a list of SNMP users configured on the device, navigate to Administration » Configure SNMP » Configure SNMP Users . The SNMP Users table appears.

198 Managing SNMP Users RUGGEDCOM ROS Chapter 5 User Guide Setup and Configuration

Figure 128: SNMP Users Table

If users have not been configured, add users as needed. For more information, refer to Section 5.6.1.2, “Adding an SNMP User” .

Section 5.6.1.2 Adding an SNMP User

Multiple users (up to a maximum of 32) can be configured for the local SNMPv3 engine, as well as SNMPv1 and SNMPv2c communities.

NOTE When employing the SNMPv1 or SNMPv2c security level, the User Name parameter maps the community name with the security group and access level.

To add a new SNMP user, do the following: 1. Navigate to Administration » Configure SNMP » Configure SNMP Users . The SNMP Users table appears.

1

Figure 129: SNMP Users Table 1. InsertRecord

2. Click InsertRecord. The SNMP Users form appears.

Adding an SNMP User 199 Chapter 5 RUGGEDCOM ROS Setup and Configuration User Guide

1

2

3

4

5

6

7

8

9 10 12

11

Figure 130: SNMP Users Form 1. Name Box 2. IP Address Box 3. v1/v2c Community Box 4. Auth Protocol Box 5. Priv Protocol Box 6. Auth Key Box 7. Confirm Auth Key Box 8. Priv Key Box 9. Confirm Priv Key Box 10. Apply Button 11. Delete Button 12. Reload Button

NOTE RUGGEDCOM ROS requires that all user passwords meet strict guidelines to prevent the use of weak passwords. When creating a new password, make sure it adheres to the following rules: • Must not be less than 6 characters in length. • Must not include the username or any 4 continuous alphanumeric characters found in the username. For example, if the username is Subnet25, the password may not be subnet25admin or subnetadmin. However, net25admin or Sub25admin is permitted. • Must have at least one alphabetic character and one number. Special characters are permitted. • Must not have more than 3 continuously incrementing or decrementing numbers. For example, Sub123 and Sub19826 are permitted, but Sub12345 is not. An alarm will generate if a weak password is configured. The weak password alarm can be disabled by the user. For more information about disabling alarms, refer to Section 4.6, “Managing Alarms” .

3. Configure the following parameter(s) as required:

Parameter Description

Name Synopsis: Any 32 characters Default: initial The name of the user. This user name also represents the security name that maps this user to the security group.

IP Address Synopsis: ###.###.###.### where ### ranges from 0 to 255 The IP address of the user's SNMP management station. If IP address is configured, SNMP requests from that user will be verified by IP address as well. SNMP Authentication trap will be

200 Adding an SNMP User RUGGEDCOM ROS Chapter 5 User Guide Setup and Configuration

Parameter Description generated to trap receivers if request was received from this user, but from any other IP address.If IP address is empty, traps can not be generated to this user, but SNMP requests will be served for this user from any IP address.

v1/v2c Community Synopsis: Any 32 characters The community string which is mapped by this user/security name to the security group if security model is SNMPv1 or SNMPv2c. If this string is left empty, it will be assumed to be equal to the same as user name.

Auth Protocol Synopsis: { noAuth, HMACMD5, HMACSHA } Default: noAuth An indication of whether messages sent on behalf of this user to/ from SNMP engine, can be authenticated, and if so, the type of authentication protocol which is used.

Priv Protocol Synopsis: { noPriv, CBC-DES } Default: noPriv An Indication of whether messages sent on behalf of this user to/ from SNMP engine can be protected from disclosure, and if so, the type of privacy protocol which is used.

Auth Key Synopsis: 31 character ASCII string The secret authentication key (password) that must be shared with SNMP client. If the key is not an emtpy string, it must be at least 6 characters long.

Confirm Auth Key Synopsis: 31 character ASCII string The secret authentication key (password) that must be shared with SNMP client. If the key is not an emtpy string, it must be at least 6 characters long.

Priv Key Synopsis: 31 character ASCII string The secret encription key (password) that must be shared with SNMP client. If the key is not an emtpy string, it must be at least 6 characters long.

Confirm Priv Key Synopsis: 31 character ASCII string The secret encription key (password) that must be shared with SNMP client. If the key is not an emtpy string, it must be at least 6 characters long.

4. Click Apply.

Section 5.6.1.3 Deleting an SNMP User

To delete an SNMP user, do the following: 1. Navigate to Administration » Configure SNMP » Configure SNMP Users . The SNMP Users table appears.

Deleting an SNMP User 201 Chapter 5 RUGGEDCOM ROS Setup and Configuration User Guide

Figure 131: SNMP Users Table

2. Select the user from the table. The SNMP Users form appears.

1

2

3

4

5

6

7

8

9 10 12

11

Figure 132: SNMP Users Form 1. Name Box 2. IP Address Box 3. v1/v2c Community Box 4. Auth Protocol Box 5. Priv Protocol Box 6. Auth Key Box 7. Confirm Auth Key Box 8. Priv Key Box 9. Confirm Priv Key Box 10. Apply Button 11. Delete Button 12. Reload Button

3. Click Delete.

202 Deleting an SNMP User RUGGEDCOM ROS Chapter 5 User Guide Setup and Configuration

Section 5.6.2 Managing Security-to-Group Mapping

The following section describes how to configure and manage security-to-group maps.

CONTENTS • Section 5.6.2.1, “Viewing a List of Security-to-Group Maps” • Section 5.6.2.2, “Adding a Security-to-Group Map” • Section 5.6.2.3, “Deleting a Security-to-Group Map”

Section 5.6.2.1 Viewing a List of Security-to-Group Maps

To view a list of security-to-group maps configured on the device, navigate to Administration » Configure SNMP » Configure SNMP Security to Group Maps . The SNMP Security to Group Maps table appears.

Figure 133: SNMP Security to Group Maps Table

If security-to-group maps have not been configured, add maps as needed. For more information, refer to Section 5.6.2.2, “Adding a Security-to-Group Map” .

Section 5.6.2.2 Adding a Security-to-Group Map

Multiple combinations of security models and groups can be mapped (up to a maximum of 32) for SNMP. To add a security-to-group map, do the following: 1. Navigate to Administration » Configure SNMP » Configure SNMP Security to Group Maps . The SNMP Security to Group Maps table appears.

Managing Security-to-Group Mapping 203 Chapter 5 RUGGEDCOM ROS Setup and Configuration User Guide

1

Figure 134: SNMP Security to Group Maps Table 1. InsertRecord

2. Click InsertRecord. The SNMP Security to Group Maps form appears.

1

2

3

4 6

5

Figure 135: SNMP Security to Group Maps Form 1. Security Model Box 2. Name Box 3. Group Box 4. Apply Button 5. Delete Button 6. Reload Button

3. Configure the following parameter(s) as required:

Parameter Description

SecurityModel Synopsis: { snmpV1, snmpV2c, snmpV3 } Default: snmpV3 The Security Model that provides the name referenced in this table.

Name Synopsis: Any 32 characters The user name which is mapped by this entry to the specified group name.

Group Synopsis: Any 32 characters The group name to which the security model and name belong. This name is used as an index to the SNMPv3 VACM Access Table.

4. Click Apply.

204 Adding a Security-to-Group Map RUGGEDCOM ROS Chapter 5 User Guide Setup and Configuration

Section 5.6.2.3 Deleting a Security-to-Group Map

To delete a security-to-group map, do the following: 1. Navigate to Administration » Configure SNMP » Configure SNMP Security to Group Maps . The SNMP Security to Group Maps table appears.

Figure 136: SNMP Security to Group Maps Table

2. Select the map from the table. The SNMP Security to Group Maps form appears.

1

2

3

4 6

5

Figure 137: SNMP Security to Group Maps Form 1. Security Model Box 2. Name Box 3. Group Box 4. Apply Button 5. Delete Button 6. Reload Button

3. Click Delete.

Section 5.6.3 Managing SNMP Groups

Multiple SNMP groups (up to a maximum of 32) can be configured to have access to SNMP.

CONTENTS • Section 5.6.3.1, “Viewing a List of SNMP Groups” • Section 5.6.3.2, “Adding an SNMP Group”

Deleting a Security-to-Group Map 205 Chapter 5 RUGGEDCOM ROS Setup and Configuration User Guide

• Section 5.6.3.3, “Deleting an SNMP Group”

Section 5.6.3.1 Viewing a List of SNMP Groups

To view a list of SNMP groups configured on the device, navigate to Administration » Configure SNMP » Configure SNMP Access . The SNMP Access table appears.

Figure 138: SNMP Access Table

If SNMP groups have not been configured, add groups as needed. For more information, refer to Section 5.6.3.2, “Adding an SNMP Group” .

Section 5.6.3.2 Adding an SNMP Group

To add an SNMP group, do the following: 1. Navigate to Administration » Configure SNMP » Configure SNMP Access . The SNMP Access table appears.

1

Figure 139: SNMP Access Table 1. InsertRecord

2. Click InsertRecord. The SNMP Access form appears.

206 Viewing a List of SNMP Groups RUGGEDCOM ROS Chapter 5 User Guide Setup and Configuration

1

2

3

4

5

6 7 9

8

Figure 140: SNMP Access Form 1. Group Box 2. Security Model Box 3. Security Level Box 4. ReadViewName Box 5. WriteViewName Box 6. NotifyViewName Box 7. Apply Button 8. Delete Button 9. Reload Button

3. Configure the following parameter(s) as required:

Parameter Description

Group Synopsis: Any 32 characters The group name to which the security model and name belong. This name is used as an index to the SNMPv3 VACM Access Table.

SecurityModel Synopsis: { snmpV1, snmpV2c, snmpV3 } Default: snmpV3 In order to gain the access rights allowed by this entry, configured security model must be in use.

SecurityLevel Synopsis: { noAuthNoPriv, authNoPriv, authPriv } Default: noAuthNoPriv The minimum level of security reqwuired in order to gain the access rights allowed by this entry. A security level of noAuthNoPriv is less than authNoPriv, which is less than authPriv.

ReadViewName Synopsis: { noView, V1Mib, allOfMib } Default: noView This parameter identifies the MIB tree(s) to which this entry authorizes read access. If the value is noView, then no read access is granted.

WriteViewName Synopsis: { noView, V1Mib, allOfMib } Default: noView This parameter identifies the MIB tree(s) to which this entry authorizes write access. If the value is noView, then no write access is granted.

NotifyViewName Synopsis: { noView, V1Mib, allOfMib } Default: noView This parameter identifies the MIB tree(s) to which this entry authorizes access for notifications. If the value is noView, then no access for notifications is granted.

Adding an SNMP Group 207 Chapter 5 RUGGEDCOM ROS Setup and Configuration User Guide

4. Click Apply.

Section 5.6.3.3 Deleting an SNMP Group

To delete an SNMP group, do the following: 1. Navigate to Administration » Configure SNMP » Configure SNMP Access . The SNMP Access table appears.

Figure 141: SNMP Access Table

2. Select the group from the table. The SNMP Access form appears.

1

2

3

4

5

6 7 9

8

Figure 142: SNMP Access Form 1. Group Box 2. Security Model Box 3. Security Level Box 4. ReadViewName Box 5. WriteViewName Box 6. NotifyViewName Box 7. Apply Button 8. Delete Button 9. Reload Button

3. Click Delete.

208 Deleting an SNMP Group RUGGEDCOM ROS Chapter 5 User Guide Setup and Configuration

Section 5.7 Managing Network Discovery

RUGGEDCOM ROS supports the Link Layer Discovery Protocol (LLDP) and RUGGEDCOM Discovery Protocol (RCDP), both Layer 2 protocols for automated network discovery.

CONTENTS • Section 5.7.1, “Network Discovery Concepts” • Section 5.7.2, “Configuring LLDP Globally” • Section 5.7.3, “Configuring LLDP for an Ethernet Port” • Section 5.7.4, “Enabling/Disabling RCDP” • Section 5.7.5, “Viewing Global Statistics and Advertised System Information” • Section 5.7.6, “Viewing Statistics for LLDP Neighbors” • Section 5.7.7, “Viewing Statistics for LLDP Ports”

Section 5.7.1 Network Discovery Concepts

The following section describes some of the concepts important to the implementation of network discovery in RUGGEDCOM ROS.

CONTENTS • Section 5.7.1.1, “Link Layer Discovery Protocol (LLDP)” • Section 5.7.1.2, “ RUGGEDCOM Discovery Protocol (RCDP)”

Section 5.7.1.1 Link Layer Discovery Protocol (LLDP)

LLDP is an IEEE standard protocol, IEEE 802.11AB, that allows a networked device to advertise its own basic networking capabilities and configuration. LLDP allows a networked device to discover its neighbors across connected network links using a standard mechanism. Devices that support LLDP are able to advertise information about themselves, including their capabilities, configuration, interconnections, and identifying information. LLDP agent operation is typically implemented as two modules: the LLDP transmit module and LLDP receive module. The LLDP transmit module, when enabled, sends the local device’s information at regular intervals, in IEEE 802.1AB standard format. Whenever the transmit module is disabled, it transmits an LLDPDU (LLDP data unit) with a time-to-live (TTL) type-length-value (TLV) containing 0 in the information field. This enables remote devices to remove the information associated with the local device in their databases. The LLDP receive module, when enabled, receives remote devices’ information and updates its LLDP database of remote systems. When new or updated information is received, the receive module initiates a timer for the valid duration indicated by the TTL TLV in the received LLDPDU. A remote system’s information is removed from the database when an LLDPDU is received from it with TTL TLV containing 0 in its information field.

Managing Network Discovery 209 Chapter 5 RUGGEDCOM ROS Setup and Configuration User Guide

NOTE LLDP is implemented to keep a record of only one device per Ethernet port. Therefore, if there are multiple devices sending LLDP information to a switch port on which LLDP is enabled, information about the neighbor on that port will change constantly.

Section 5.7.1.2 RUGGEDCOM Discovery Protocol (RCDP)

RUGGEDCOM Discovery Protocol (RCDP) supports the deployment of RUGGEDCOM ROS-based devices that have not been configured since leaving the factory. RUGGEDCOM ROS devices that have not been configured all have the default IP (Layer 3) address. Connecting more than one of them on a Layer 2 network means that one cannot use standard IP-based configuration tools to configure them. The behavior of IP-based mechanisms such as the web interface, SSH, telnet, or SNMP will all be undefined. Since RCDP operates at Layer 2, it can be used to reliably and unambiguously address multiple devices even though they may share the same IP configuration. Siemens's RUGGEDCOM Explorer is a lightweight, standalone Windows application that supports RCDP. It is capable of discovering, identifying and performing basic configuration of RUGGEDCOM ROS-based devices via RCDP. The features supported by RCDP include: • Discovery of RUGGEDCOM ROS-based devices over a Layer 2 network. • Retrieval of basic network configuration, RUGGEDCOM ROS version, order code, and serial number. • Control of device LEDs for easy physical identification. • Configuration of basic identification, networking, and authentication parameters. For security reasons, RUGGEDCOM Explorer will attempt to disable RCDP on all devices when Explorer is shut down. If RUGGEDCOM Explorer is unable to disable RCDP on a device, RUGGEDCOM ROS will automatically disable RCDP after approximately one hour of inactivity.

NOTE RCDP is not compatible with VLAN-based network configurations. For correct operation of RUGGEDCOM Explorer, no VLANs (tagged or untagged) must be configured. All VLAN configuration items must be at their default settings.

NOTE RUGGEDCOM ROS responds to RCDP requests only. It does not under any circumstances initiate any RCDP-based communication.

Section 5.7.2 Configuring LLDP Globally

To configure the global settings for LLDP, do the following: 1. Navigate to Network Discovery » Link Layer Discovery Protocol » Configure Global LLDP Parameters . The Global LLDP Parameters form appears.

210 RUGGEDCOM Discovery Protocol (RCDP) RUGGEDCOM ROS Chapter 5 User Guide Setup and Configuration

1

2

3

4

5

6 7

Figure 143: Global LLDP Parameters Form 1. State Options 2. Tx Interval Box 3. Tx Hold Box 4. Reinit Delay Box 5. Tx Delay Box 6. Apply Button 7. Reload Button

2. Configure the following parameter(s) as required:

Parameter Description

State Synopsis: { Disabled, Enabled } Default: Enabled Enables LLDP protocol. Note that LLDP is enabled on a port when LLDP is enabled globally and along with enabling per port setting in Port LLDP Parameters menu.

Tx Interval Synopsis: 5 to 32768 s Default: 30 s The interval at which LLDP frames are transmitted on behalf of this LLDP agent.

Tx Hold Synopsis: 2 to 10 Default: 4 The multiplier of the Tx Interval parameter that determines the actual time-to-live (TTL) value used in a LLDPDU. The actual TTL value can be expressed by the following formula:

TTL = MIN(65535, (Tx Interval * Tx Hold))

Reinit Delay Synopsis: 1 to 10 s Default: 2 s The delay in seconds from when the value of Admin Status parameter of a particular port becomes 'Disbled' until re- initialization will be lattempted.

Tx Delay Synopsis: 1 to 8192 s Default: 2 s The delay in seconds between successive LLDP frame transmissions initiated by value or status changed. The recommended value is set by the following formula:

1 <= txDelay <= (0.25 * Tx Interval)

3. Click Apply.

Configuring LLDP Globally 211 Chapter 5 RUGGEDCOM ROS Setup and Configuration User Guide

Section 5.7.3 Configuring LLDP for an Ethernet Port

To configure LLDP for a specific Ethernet Port, do the following: 1. Navigate to Network Discovery » Link Layer Discovery Protocol » Configure Port LLDP Parameters . The Port LLDP Parameters table appears.

Figure 144: Port LLDP Parameters Table

2. Select a port. The Port LLDP Parameters form appears.

1

2

3

4 5

Figure 145: Port LLDP Parameters Form 1. Port Box 2. Admin Status List 3. Notifications Options 4. Apply Button 5. Reload Button

3. Configure the following parameter(s) as required:

Parameter Description

Port Synopsis: 1 to maximum port number Default: 1 The port number as seen on the front plate silkscreen of the switch.

Admin Status Synopsis: { rxTx, txOnly, rxOnly, Disabled } Default: rxTx

212 Configuring LLDP for an Ethernet Port RUGGEDCOM ROS Chapter 5 User Guide Setup and Configuration

Parameter Description rxTx: the local LLDP agent can both transmit and receive LLDP frames through the port. txOnly: the local LLDP agent can only transmit LLDP frames. rxOnly: the local LLDP agent can only receive LLDP frames. disabled: the local LLDP agent can neither transmit or receive LLDP frames.

Notifications Synopsis: { Disabled, Enabled } Default: Disabled Disabling notifications will prevent sending notifications and generating alarms for particular port from the LLDP agent.

4. Click Apply.

Section 5.7.4 Enabling/Disabling RCDP

RUGGEDCOM ROS supports the RUGGEDCOM Discovery Protocol (RCDP). RCDP supports the deployment of RUGGEDCOM ROS-based devices that have not been configured since leaving the factory. RUGGEDCOM ROS devices that have not been configured all have the default IP (Layer 3) address. Connecting more than one of them on a Layer 2 network means that one cannot use standard IP-based configuration tools to configure them. The behavior of IP-based mechanisms such as the web interface, SSH, telnet, or SNMP will all be undefined. Since RCDP operates at Layer 2, it can be used to reliably and unambiguously address multiple devices even though they may share the same IP configuration. Siemens's RUGGEDCOM Explorer is a lightweight, standalone Windows application that supports RCDP. It is capable of discovering, identifying and performing basic configuration of RUGGEDCOM ROS-based devices via RCDP. The features supported by RCDP include: • Discovery of RUGGEDCOM ROS-based devices over a Layer 2 network. • Retrieval of basic network configuration, RUGGEDCOM ROS version, order code, and serial number. • Control of device LEDs for easy physical identification. • Configuration of basic identification, networking, and authentication parameters. For security reasons, RUGGEDCOM Explorer will attempt to disable RCDP on all devices when Explorer is shut down. If RUGGEDCOM Explorer is unable to disable RCDP on a device, RUGGEDCOM ROS will automatically disable RCDP after approximately one hour of inactivity.

NOTE RCDP is not compatible with VLAN-based network configurations. For correct operation of RUGGEDCOM Explorer, no VLANs (tagged or untagged) must be configured. All VLAN configuration items must be at their default settings.

NOTE RUGGEDCOM ROS responds to RCDP requests only. It does not under any circumstances initiate any RCDP-based communication.

To enable or disable RCDP, do the following: 1. Navigate to Network Discovery » RuggedCom Discovery Protocol » Configure RCDP Parameters . The RCDP Parameters form appears.

Enabling/Disabling RCDP 213 Chapter 5 RUGGEDCOM ROS Setup and Configuration User Guide

1

2 3

Figure 146: RCDP Parameters Form 1. RCDP Discovery Options 2. Apply Button 3. Reload Button

2. Select Enabled to enable RCDP, or select Disabled to disable RCDP. 3. Click Apply.

Section 5.7.5 Viewing Global Statistics and Advertised System Information

To view global statistics for LLDP and the system information that is advertised to neighbors, navigate to Network Discovery » Link Layer Discovery Protocol » View LLDP Global Remote Statistics . The LLDP Global Remote Statistics form appears.

1

2

3

4

5

Figure 147: LLDP Global Remote Statistics Form 1. Inserts Box 2. Deletes Box 3. Drops Box 4. Ageouts Box 5. Reload Button

This form displays the following information:

Parameter Description

Inserts Synopsis: 0 to 4294967295 A number of times the entry in LLDP Neighbor Information Table was inserted.

Deletes Synopsis: 0 to 4294967295 A number of times the entry in LLDP Neighbor Information Table was deleted.

Drops Synopsis: 0 to 4294967295

Viewing Global Statistics and Advertised System 214 Information RUGGEDCOM ROS Chapter 5 User Guide Setup and Configuration

Parameter Description A number of times an entry was deleted from LLDP Neighbor Information Table because the information timeliness interval has expired.

Ageouts Synopsis: 0 to 4294967295 A counter of all TLVs discarded.

Section 5.7.6 Viewing Statistics for LLDP Neighbors

To view statistics for LLDP neighbors, navigate to Network Discovery » Link Layer Discovery Protocol » View LLDP Neighbor Information . The LLDP Neighbor Information table appears.

1

2

3

4

5

6

Figure 148: LLDP Neighbor Information Table 1. Port Box 2. ChassisId Box 3. PortId Box 4. SysName Box 5. SysDesc Box 6. Reload Button

This form displays the following information:

Parameter Description

Port Synopsis: 1 to maximum port number The local port associated with this entry.

ChassisId Synopsis: Any 45 characters Chassis Id information received from remote LLDP agent.

PortId Synopsis: Any 45 characters Port Id information received from remote LLDP agent.

SysName Synopsis: Any 45 characters System Name information received from remote LLDP agent.

SysDesc Synopsis: Any 45 characters System Descriptor information received from remote LLDP agent.

Viewing Statistics for LLDP Neighbors 215 Chapter 5 RUGGEDCOM ROS Setup and Configuration User Guide

Section 5.7.7 Viewing Statistics for LLDP Ports

To view statistics for LLDP ports, navigate to Network Discovery » Link Layer Discovery Protocol » View LLDP Statistics . The LLDP Statistics table appears.

Figure 149: LLDP Statistics Table

This table displays the following information:

Parameter Description

Port Synopsis: 1 to maximum port number The port number as seen on the front plate silkscreen of the switch.

FrmDrop Synopsis: 0 to 4294967295 A counter of all LLDP frames discarded.

ErrFrm Synopsis: 0 to 4294967295 A counter of all LLDPDUs received with detectable errors.

FrmIn Synopsis: 0 to 4294967295 A counter of all LLDPDUs received.

FrmOut Synopsis: 0 to 4294967295 A counter of all LLDPDUs transmitted.

Ageouts Synopsis: 0 to 4294967295 A counter of the times that a neighbor's information has been deleted from the LLDP remote system MIB because the txinfoTTL timer has expired.

TLVsDrop Synopsis: 0 to 4294967295 A counter of all TLVs discarded.

TLVsUnknown Synopsis: 0 to 4294967295 A counter of all TLVs received on the port that are not recognized by the LLDP local agent.

216 Viewing Statistics for LLDP Ports RUGGEDCOM ROS Chapter 5 User Guide Setup and Configuration

Section 5.8 Managing Multicast Filtering

Multicast traffic can be filtered using IGMP (Internet Group Management Protocol) snooping or GMRP (GARP Multicast Registration Protocol).

CONTENTS • Section 5.8.1, “Managing IGMP” • Section 5.8.2, “Managing GMRP”

Section 5.8.1 Managing IGMP

IGMP is used by IP hosts to report their host group memberships with multicast routers. As hosts join and leave specific multicast groups, streams of traffic are directed to or withheld from that host. The IGMP protocol operates between multicast routers and IP hosts. When an unmanaged switch is placed between multicast routers and their hosts, the multicast streams will be distributed to all ports.This may introduce significant traffic onto ports that do not require it and receive no benefit from it. IGMP Snooping, when enabled, will act on IGMP messages sent from the router and the host, restricting traffic streams to the appropriate LAN segments.

IMPORTANT! RUGGEDCOM ROS restricts IGMP hosts from subscribing to the following special multicast addresses: • 224.0.0.0 to 224.0.0.255 • 224.0.1.129 These addresses are reserved for routing protocols and IEEE 1588. If an IGMP membership report contains one of these addresses, the report is forwarded by the switch without learning about the host.

CONTENTS • Section 5.8.1.1, “IGMP Concepts” • Section 5.8.1.2, “Viewing a List of Multicast Group Memberships” • Section 5.8.1.3, “Viewing Forwarding Information for Multicast Groups” • Section 5.8.1.4, “Configuring IGMP”

Section 5.8.1.1 IGMP Concepts

The following describes some of the concepts important to the implementation of multicast filtering using IGMP:

IGMP In Operation The following network diagram provides a simple example of the use of IGMP.

Managing Multicast Filtering 217 Chapter 5 RUGGEDCOM ROS Setup and Configuration User Guide

1

P1

2 M1 M2 2

3 3

C3 C4 C1 C2

4 4 5 4 4

Figure 150: Example – IGMP In Operation 1. Producer 2. Membership Queries 3. Membership Reports 4. Consumer 5. Multicast Router

One producer IP host (P1) is generating two IP multicast streams, M1 and M2. There are four potential consumers of these streams, C1 through C4. The multicast router discovers which host wishes to subscribe to which stream by sending general membership queries to each segment. In this example, the general membership query sent to the C1-C2 segment is answered by a membership report (or join) indicating the desire to subscribe to stream M2. The router will forward the M2 stream to the C1-C2 segment. In a similar fashion, the router discovers that it must forward stream M1 to segment C3-C4. A consumer may join any number of multicast groups, issuing a membership report for each group. When a host issues a membership report, other hosts on the same network segment that also require membership to the same group suppress their own requests, since they would be redundant. In this way, the IGMP protocol guarantees the segment will issue only one membership report for each group. The router periodically queries each of its segments in order to determine whether at least one consumer still subscribes to a given stream. If it receives no responses within a given time period (usually two query intervals), the router will prune the multicast stream from the given segment. A more common method of pruning occurs when consumers wishing to unsubscribe issue an IGMP leave group message. The router will immediately issue a group-specific membership query to determine whether there are any remaining subscribers of that group on the segment. After the last consumer of a group has unsubscribed, the router will prune the multicast stream from the given segment.

Switch IGMP Operation The IGMP Snooping feature provides a means for switches to snoop (i.e. watch) the operation of routers, respond with joins/leaves on the behalf of consumer ports, and prune multicast streams accordingly. There are two modes of IGMP the switch can be configured to assume: active and passive. • Active Mode IGMP supports a routerless mode of operation. When such a switch is used without a multicast router, it is able to function as if it is a multicast router sending IGMP general queries.

218 IGMP Concepts RUGGEDCOM ROS Chapter 5 User Guide Setup and Configuration

• Passive Mode When such a switch is used in a network with a multicast router, it can be configured to run Passive IGMP. This mode prevents the switch from sending the queries that can confuse the router causing it to stop issuing IGMP queries.

NOTE A switch running in passive mode requires the presence of a multicast router or it will be unable to forward multicast streams at all if no multicast routers are present.

NOTE At least one IGMP Snooping switch must be in active mode to make IGMP functional.

IGMP Snooping Rules IGMP Snooping adheres to the following rules: • When a multicast source starts multicasting, the traffic stream will be immediately blocked on segments from which joins have not been received. • Unless configured otherwise, the switch will forward all multicast traffic to the ports where multicast routers are attached. • Packets with a destination IP multicast address in the 224.0.0.X range that are not IGMP are always forwarded to all ports. This behavior is based on the fact that many systems do not send membership reports for IP multicast addresses in this range while still listening to such packets. • The switch implements IGMPv2 proxy-reporting (i.e. membership reports received from downstream are summarized and used by the switch to issue its own reports). • The switch will only send IGMP membership reports out of those ports where multicast routers are attached, as sending membership reports to hosts could result in unintentionally preventing a host from joining a specific group. • Multicast routers use IGMP to elect a master router known as the querier. The querier is the router with the lowest IP address. All other routers become non-queriers, participating only in forwarding multicast traffic. Switches running in active mode participate in the querier election the same as multicast routers. • When the querier election process is complete, the switch simply relays IGMP queries received from the querier. • When sending IGMP packets, the switch uses its own IP address, if it has one, for the VLAN on which packets are sent, or an address of 0.0.0.0, if it does not have an assigned IP address.

NOTE IGMP Snooping switches perform multicast pruning using a multicast frames’ destination MAC multicast address, which depends on the group IP multicast address. IP address W.X.Y.Z corresponds to MAC address 01-00-5E-XX-YY-ZZ where XX is the lower 7 bits of X, and YY and ZZ are simply Y and Z coded in hexadecimal. One can note that IP multicast addresses, such as 224.1.1.1 and 225.1.1.1, will both map onto the same MAC address 01-00-5E-01-01-01. This is a problem for which the IETF Network Working Group currently has offered no solution. Users are advised to be aware of and avoid this problem.

IGMP and RSTP An RSTP change of topology can render the routes selected to carry multicast traffic as incorrect. This results in lost multicast traffic.

IGMP Concepts 219 Chapter 5 RUGGEDCOM ROS Setup and Configuration User Guide

If RSTP detects a change in the network topology, IGMP will take some actions to avoid the loss of multicast connectivity and reduce network convergence time: • The switch will immediately issue IGMP queries (if in IGMP Active mode) to obtain potential new group membership information. • The switch can be configured to flood multicast streams temporarily out of all ports that are not configured as RSTP Edge Ports.

Combined Router and Switch IGMP Operation The following example illustrates the challenges faced with multiple routers, VLAN support and switching. Producer P1 resides on VLAN 2 while P2 resides on VLAN 3. Consumer C1 resides on both VLANs whereas C2 and C3 reside on VLANs 3 and 2, respectively. Router 2 resides on VLAN 2, presumably to forward multicast traffic to a remote network or act as a source of multicast traffic itself.

P1 2 3

1

P2 4

C1 C2 C3

5

Figure 151: Example – Combined Router and Switch IGMP In Operation 1. Producer 2. Multicast Router 1 3. Multicast Router 2 4. Switch 5. Host

In this example: • P1, Router 1, Router 2 and C3 are on VLAN 2 • P2 and C2 are on VLAN 3 • C1 is on both VLAN 2 and 3 Assuming that router 1 is the querier for VLAN 2 and router 2 is simply a non-querier, the switch will periodically receive queries from router 1 and maintain the information concerning which port links to the multicast router. However, the switch port that links to router 2 must be manually configured as a router port. Otherwise, the switch will send neither multicast streams nor joins/leaves to router 2. Note that VLAN 3 does not have an external multicast router. The switch should be configured to operate in its routerless mode and issue general membership queries as if it is the router. • Processing Joins If host C1 wants to subscribe to the multicast streams for both P1 and P2, it will generate two membership reports. The membership report from C1 on VLAN 2 will cause the switch to immediately initiate its own membership report to multicast router 1 (and to issue its own membership report as a response to queries).

220 IGMP Concepts RUGGEDCOM ROS Chapter 5 User Guide Setup and Configuration

The membership report from host C1 for VLAN 3 will cause the switch to immediately begin forwarding multicast traffic from producer P2 to host C2. • Processing Leaves When host C1 decides to leave a multicast group, it will issue a leave request to the switch. The switch will poll the port to determine if host C1 is the last member of the group on that port. If host C1 is the last (or only) member, the group will immediately be pruned from the port. Should host C1 leave the multicast group without issuing a leave group message and then fail to respond to a general membership query, the switch will stop forwarding traffic after two queries. When the last port in a multicast group leaves the group (or is aged-out), the switch will issue an IGMP leave report to the router.

Section 5.8.1.2 Viewing a List of Multicast Group Memberships

Using IGMP snooping, RUGGEDCOM ROS records group membership information on a per-port basis based on membership reports it observes between the router and host. To view a list of multicast group memberships, navigate to Multicast Filtering » View IGMP Group Membership . The IGMP Group Membership table appears.

Figure 152: IGMP Group Membership Table

This table provides the following information:

Parameter Description

Port Synopsis: 1 to maximum port number The port number as seen on the front plate silkscreen of the switch.

VID Synopsis: 0 to 65535 VLAN Identifier of the VLAN upon which the multicast group operates.

Group Synopsis: ###.###.###.### where ### ranges from 0 to 255 Multicast Group Address.

Ver Synopsis: { v3, v2, v1 } Specifies the IGMP version of the learnt multicast group.

Reporter Synopsis: ###.###.###.### where ### ranges from 0 to 255 Specifies the source IP address that is reporting subscription to the multicast group.

Age Synopsis: 0 to 7210 s Specifies the current age of the IP multicast group learned on the port in seconds.

Viewing a List of Multicast Group Memberships 221 Chapter 5 RUGGEDCOM ROS Setup and Configuration User Guide

If the table is empty, do the following: • Make sure traffic is being sent to the device. • Make sure IGMP is properly configured on the device. For more information, refer to Section 5.8.1.4, “Configuring IGMP” .

Section 5.8.1.3 Viewing Forwarding Information for Multicast Groups

Multicast forwarding information for every source, group and VLAN combination learned by RUGGEDCOM ROS is recorded in the IGMP Multicast Forwarding table. To view the IGMP Multicast Forwarding table, navigate to Multicast Filtering » View IGMP Multicast Forwarding . The IGMP Multicast Forwarding table appears.

Figure 153: IGMP Multicast Forwarding Table

This table provides the following information:

Parameter Description

VID Synopsis: 0 to 65535 VLAN Identifier of the VLAN upon which the multicast group operates.

Group Synopsis: ###.###.###.### where ### ranges from 0 to 255 Multicast Group Address.

Source Synopsis: ###.###.###.### where ### ranges from 0 to 255 or { * } Source Address. * means all possible source addresses.

Joined Ports Synopsis: Comma-separated list of ports All ports that currently receive multicast traffic for the specified multicast group.

Router Ports Synopsis: Comma-separated list of ports All ports that have been manually configured or dynamically discovered (by observing router specific traffic) as ports that link to multicast routers.

If the table is empty, do the following: • Make sure traffic is being sent to the device. • Make sure IGMP is properly configured on the device. For more information, refer to Section 5.8.1.4, “Configuring IGMP” .

222 Viewing Forwarding Information for Multicast Groups RUGGEDCOM ROS Chapter 5 User Guide Setup and Configuration

Section 5.8.1.4 Configuring IGMP

To configure the IGMP, do the following: 1. Make sure one or more static VLANs exist with IGMP enabled. For more information, refer to Section 5.1.5, “Managing Static VLANs” . 2. Navigate to Multicast Filtering » Configure IGMP Parameters . The IGMP Parameters form appears.

1

2

3

4

5

6

7 8

Figure 154: IGMP Parameters Form 1. Mode Options 2. IGMP Version 3. Query Interval Box 4. Router Ports Box 5. Router Forwarding Options 6. RSTP Flooding Options 7. Apply Button 8. Reload Button

3. Configure the following parameter(s) as required:

Parameter Description

Mode Synopsis: { Passive, Active } Default: Passive Specifies the IGMP mode. Options include: • PASSIVE – the switch passively snoops IGMP traffic and never sends IGMP queries • ACTIVE – the switch generates IGMP queries, if no queries from a better candidate for being the querier are detected for a while.

IGMP Version Synopsis: { v2, v3 } Default: v2 Specifies the configured IGMP version on the switch. Options include: • v2 – Sets the IGMP version to version 2. When selected for a snooping switch, all IGMP reports and queries greater than v2 are forwarded, but not added to the IGMP Multicast Forwarding table. • v3 – Sets the IGMP version to version 3. General queries are generated in IGMPv3 format, all versions of IGMP messages are processed by the switch, and traffic is pruned based on multicast group address only.

Query Interval Synopsis: 10 to 3600 Default: 60 s The time interval between IGMP queries generated by the switch.

Configuring IGMP 223 Chapter 5 RUGGEDCOM ROS Setup and Configuration User Guide

Parameter Description

NOTE This parameter also affects the Group Membership Interval (i.e. the group subscriber aging time), therefore, it takes effect even in PASSIVE mode.

Router Ports Synopsis: Comma-separated list of ports Default: None This parameter specifies ports that connect to multicast routers. If you do not configure known router ports, the switch may be able to detect them, however it is advisable to pre-configure them.

Router Forwarding Synopsis: { Off, On } Default: On This parameter specifies whether multicast streams will be always forwarded to multicast routers.

RSTP Flooding Synopsis: { Off, On } Default: Off This parameter specifies whether multicast streams will be flooded out of all RSTP non-edge ports upon topology change detection. Such flooding is desirable, if guaranteed multicast stream delivery after topology change is most important.

4. Click Apply.

Section 5.8.2 Managing GMRP

The GMRP is an application of the Generic Attribute Registration Protocol (GARP) that provides a Layer 2 mechanism for managing multicast group memberships in a bridged Layer 2 network. It allows Ethernet switches and end stations to register and unregister membership in multicast groups with other switches on a LAN, and for that information to be disseminated to all switches in the LAN that support Extended Filtering Services. GMRP is an industry-standard protocol first defined in IEEE 802.1D-1998 and extended in IEEE 802.1Q-2005. GARP was defined in IEEE 802.1D-1998 and updated in 802.1D-2004.

NOTE GMRP provides similar functionality at Layer 2 to what IGMP provides at Layer 3.

CONTENTS • Section 5.8.2.1, “GMRP Concepts” • Section 5.8.2.2, “Viewing a Summary of Multicast Groups” • Section 5.8.2.3, “Configuring GMRP Globally” • Section 5.8.2.4, “Configuring GMRP for Specific Ethernet Ports” • Section 5.8.2.5, “Viewing a List of Static Multicast Groups” • Section 5.8.2.6, “Adding a Static Multicast Group”

224 Managing GMRP RUGGEDCOM ROS Chapter 5 User Guide Setup and Configuration

• Section 5.8.2.7, “Deleting a Static Multicast Group”

Section 5.8.2.1 GMRP Concepts

The following describes some of the concepts important to the implementation of multicast filtering using GMRP:

Joining a Multicast Group In order to join a multicast group, an end station transmits a GMRP join message. The switch that receives the join message adds the port through which the message was received to the multicast group specified in the message. It then propagates the join message to all other hosts in the VLAN, one of which is expected to be the multicast source. When a switch transmits GMRP updates (from GMRP-enabled ports), all of the multicast groups known to the switch, whether configured manually or learned dynamically through GMRP, are advertised to the rest of network. As long as one host on the Layer 2 network has registered for a given multicast group, traffic from the corresponding multicast source will be carried on the network. Traffic multicast by the source is only forwarded by each switch in the network to those ports from which it has received join messages for the multicast group.

Leaving a Multicast Group Periodically, the switch sends GMRP queries in the form of a leave all message. If a host (either a switch or an end station) wishes to remain in a multicast group, it reasserts its group membership by responding with an appropriate join request. Otherwise, it can either respond with a leave message or simply not respond at all. If the switch receives a leave message or receives no response from the host for a timeout period, the switch removes the host from the multicast group.

Notes About GMRP Since GMRP is an application of GARP, transactions take place using the GARP protocol. GMRP defines the following two Attribute Types: • The Group Attribute Type, used to identify the values of group MAC addresses • The Service Requirement Attribute Type, used to identify service requirements for the group Service Requirement Attributes are used to change the receiving port's multicast filtering behavior to one of the following: • Forward All Multicast group traffic in the VLAN, or • Forward All Unknown Traffic (Multicast Groups) for which there are no members registered in the device in a VLAN If GMRP is disabled on the RS900, GMRP packets received will be forwarded like any other traffic. Otherwise, GMRP packets will be processed by the RS900, and not forwarded.

Establishing Membership with GMRP The following example illustrates how a network of hosts and switches can dynamically join two multicast groups using GMRP.

GMRP Concepts 225 Chapter 5 RUGGEDCOM ROS Setup and Configuration User Guide

In this scenario, there are two multicast sources, S1 and S2, multicasting to Multicast Groups 1 and 2, respectively. A network of five switches, including one core switch (B), connects the sources to two hosts, H1 and H2, which receive the multicast streams from S1 and S2, respectively.

1 S1

D1 D D2 B3 B1 B B2 B4 A1 E1 C1 A E C 2 A2 E2 C2

H1 H2 3 1 S2

Figure 155: Example – Establishing Membership with GMRP 1. Multicast Source 2. Switch 3. Multicast Host

The hosts and switches establish membership with the Multicast Group 1 and 2 as follows: 1. Host H1 is GMRP unaware, but needs to see traffic for Multicast Group 1. Therefore, Port E2 on Switch E is statically configured to forward traffic for Multicast Group 1. 2. Switch E advertises membership in Multicast Group 1 to the network through Port E1, making Port B4 on Switch B a member of Multicast Group 1. 3. Switch B propagates the join message, causing Ports A1, C1 and D1 to become members of Multicast Group 1. 4. Host H2 is GMRP-aware and sends a join request for Multicast Group 2 to Port C2, which thereby becomes a member of Multicast Group 2. 5. Switch C propagates the join message, causing Ports A1, B2, D1 and E1 to become members of Multicast Group 2. Once GMRP-based registration has propagated through the network, multicast traffic from S1 and S2 can reach its destination as follows: • Source S1 transmits multicast traffic to Port D2 which is forwarded via Port D1, which has previously become a member of Multicast Group 1. • Switch B forwards the Group 1 multicast via Port B4 towards Switch E. • Switch E forwards the Group 1 multicast via Port E2, which has been statically configured for membership in Multicast Group 1. • Host H1, connected to Port E2, thus receives the Group 1 multicast. • Source S2 transmits multicast traffic to Port A2, which is then forwarded via port A1, which has previously become a member of Multicast Group 2. • Switch B forwards the Group 2 multicast via Port B2 towards Switch C.

226 GMRP Concepts RUGGEDCOM ROS Chapter 5 User Guide Setup and Configuration

• Switch C forwards the Group 2 multicast via Port C2, which has previously become a member of Group 2. • Ultimately, Host H2, connected to Port C2, receives the Group 2 multicast.

Section 5.8.2.2 Viewing a Summary of Multicast Groups

To view a summary of all multicast groups, navigate to Multicast Filtering » View Multicast Group Summary . The Multicast Group Summary table appears.

Figure 156: Multicast Group Summary Table

This table provides the following information:

Parameter Description

VID Synopsis: 0 to 65535 VLAN Identifier of the VLAN upon which the multicast group operates.

MAC Address Synopsis: ##-##-##-##-##-## where ## ranges 0 to FF Multicast group MAC address.

Static Ports Synopsis: Any combination of numbers valid for this parameter Ports that joined this group statically through static configuration in Static MAC Table and to which the multicast group traffic is forwarded.

GMRP Dynamic Ports Synopsis: Any combination of numbers valid for this parameter Ports that joined this group dynamically through GMRP Application and to which the multicast group traffic is forwarded.

Section 5.8.2.3 Configuring GMRP Globally

To configure global settings for GMRP, do the following: 1. Navigate to Multicast Filtering » Configure Global GMRP Parameters . The Global GMRP Parameters form appears.

Viewing a Summary of Multicast Groups 227 Chapter 5 RUGGEDCOM ROS Setup and Configuration User Guide

1

2

3

4 5

Figure 157: Global GMRP Parameters Form 1. GMRP Enable Options 2. RSTP Flooding Options 3. Leave Timer Box 4. Apply Button 5. Reload Button

2. Configure the following parameter(s) as required:

Parameter Description

GMRP Enable Synopsis: { No, Yes } Default: No Globally enable or disable GMRP. When GMRP is globally disabled, GMRP configurations on individual ports are ignored. When GMRP is globally enabled, each port can be individually configured.

RSTP Flooding Synopsis: { On, Off } Default: Off This parameter specifies whether multicast streams will be flooded out of all RSTP non-edge ports upon topology change detection. Such flooding is desirable, if guaranteed multicast stream delivery after topology change is most important.

Leave Timer Synopsis: 600 to 300000 ms Default: 4000 ms Time (milliseconds) to wait after issuing Leave or LeaveAll before removing registered multicast groups. If Join messages for specific addresses are received before this timer expires, the addresses will be kept registered.

3. Click Apply.

Section 5.8.2.4 Configuring GMRP for Specific Ethernet Ports

To configure GMRP for a specific Ethernet port, do the following: 1. Make sure the global settings for GMRP have been configured. For more information, refer to Section 5.8.2.3, “Configuring GMRP Globally” . 2. Navigate to Multicast Filtering » Configure Port GMRP Parameters . The Port GMRP Parameters table appears.

228 Configuring GMRP for Specific Ethernet Ports RUGGEDCOM ROS Chapter 5 User Guide Setup and Configuration

Figure 158: Port GMRP Parameters Table

3. Select an Ethernet port. The Port GMRP Parameters form appears.

1

2

3 4

Figure 159: Port GMRP Parameters Form 1. Port(s) Box 2. GMRP List 3. Apply Button 4. Reload Button

4. Configure the following parameter(s) as required:

Parameter Description

Port(s) Synopsis: Any combination of numbers valid for this parameter The port number as seen on the front plate silkscreen of the switch (or a list of ports, if aggregated in a port trunk).

GMRP Synopsis: { Disabled, Adv Only, Adv&Learn } Default: Default: Disabled Configures GMRP (GARP Multicast Registration Protocol) operation on the port. There are several GMRP operation modes: • DISABLED - the port is not capable of any GMRP processing. • ADVERTISE ONLY - the port will declare all MCAST addresses existing in the switch (configured or learned) but will not learn any MCAST addresses. • ADVERTISE & LEARN - the port will declare all MCAST Addresses existing in the switch (configured or learned) and can dynamically learn MCAST addresses.

5. Click Apply.

Configuring GMRP for Specific Ethernet Ports 229 Chapter 5 RUGGEDCOM ROS Setup and Configuration User Guide

Section 5.8.2.5 Viewing a List of Static Multicast Groups

To view a list of static multicast groups, navigate to Multicast Filtering » Configure Static Multicast Groups . The Static Multicast Groups table appears.

Figure 160: Static Multicast Groups Table

If a static multicast group is not listed, add the group. For more information, refer to Section 5.8.2.6, “Adding a Static Multicast Group” .

Section 5.8.2.6 Adding a Static Multicast Group

To add a static multicast group from another device, do the following: 1. Navigate to Multicast Filtering » Configure Static Multicast Groups . The Static Multicast Groups table appears.

1

Figure 161: Static Multicast Groups Table 1. InsertRecord

2. Click InsertRecord. The Static Multicast Groups form appears.

230 Viewing a List of Static Multicast Groups RUGGEDCOM ROS Chapter 5 User Guide Setup and Configuration

1

2

3

4

5 7

6

Figure 162: Static Multicast Groups Form 1. MAC Address Box 2. VID Box 3. CoS List 4. Ports Box 5. Apply Button 6. Delete Button 7. Reload Button

3. Configure the following parameter(s) as required:

Parameter Description

MAC Address Synopsis: ##-##-##-##-##-## where ## ranges 0 to FF Default: 00-00-00-00-00-00 Multicast group MAC address.

VID Synopsis: 1 to 4094 Default: 1 VLAN Identifier of the VLAN upon which the multicast group operates.

CoS Synopsis: { N/A, Normal, Medium, High, Crit } Default: N/A Prioritizes traffic for the specified MAC address. To not prioritize traffic based on the address, select N/A.

Ports Synopsis: Any combination of numbers valid for this parameter Default: None Ports to which the multicast group traffic is forwarded.

4. Click Apply.

Section 5.8.2.7 Deleting a Static Multicast Group

To delete a static multicast group, do the following: 1. Navigate to Multicast Filtering » Configure Static Multicast Groups . The Static Multicast Groups table appears.

Deleting a Static Multicast Group 231 Chapter 5 RUGGEDCOM ROS Setup and Configuration User Guide

Figure 163: Static Multicast Groups Table

2. Select the group from the table. The Static Multicast Groups form appears.

1

2

3

4

5 7

6

Figure 164: Static Multicast Groups Form 1. MAC Address Box 2. VID Box 3. Priority Box 4. Ports Box 5. Apply Button 6. Delete Button 7. Reload Button

3. Click Delete.

Section 5.9 Managing Port Security

Port security, or port access control, provides the ability to filter or accept traffic from specific MAC addresses. Port security works by inspecting the source MAC addresses of received frames and validating them against the list of MAC addresses authorized by the port. Unauthorized frames are filtered and, optionally, the part that received the frame can be shut down permanently or for a specified period of time. An alarm will be raised indicating the detected unauthorized MAC address. Frames to unknown destination addresses are flooded through secure ports.

CONTENTS • Section 5.9.1, “Port Security Concepts” • Section 5.9.2, “Viewing a List of Authorized MAC Addresses” • Section 5.9.3, “Configuring Port Security”

232 Managing Port Security RUGGEDCOM ROS Chapter 5 User Guide Setup and Configuration

• Section 5.9.4, “Configuring IEEE 802.1X”

Section 5.9.1 Port Security Concepts

The following section describes some of the concepts important to the implementation of port security in RUGGEDCOM ROS.

CONTENTS • Section 5.9.1.1, “Static MAC Address-Based Authentication” • Section 5.9.1.2, “IEEE 802.1x Authentication” • Section 5.9.1.3, “IEEE 802.1X Authentication with MAC Address-Based Authentication” • Section 5.9.1.4, “Assigning VLANS with Tunnel Attributes”

Section 5.9.1.1 Static MAC Address-Based Authentication

With this method, the switch validates the source MAC addresses of received frames against the contents in the Static MAC Address Table. RUGGEDCOM ROS also supports a highly flexible Port Security configuration which provides a convenient means for network administrators to use the feature in various network scenarios. A Static MAC address can be configured without a port number being explicitly specified. In this case, the configured MAC address will be automatically authorized on the port where it is detected. This allows devices to be connected to any secure port on the switch without requiring any reconfiguration. The switch can also be programmed to learn (and, thus, authorize) a pre-configured number of the first source MAC addresses encountered on a secure port. This enables the capture of the appropriate secure addresses when first configuring MAC address-based authorization on a port. Those MAC addresses are automatically inserted into the Static MAC Address Table and remain there until explicitly removed by the user.

Section 5.9.1.2 IEEE 802.1x Authentication

The IEEE 802.1x standard defines a mechanism for port-based network access control and provides a means of authenticating and authorizing devices attached to LAN ports. Although IEEE 802.1x is mostly used in wireless networks, this method is also implemented in wired switches. The IEEE 802.1x standard defines three major components of the authentication method: Supplicant, Authenticator and Authentication server. RUGGEDCOM ROS supports the Authenticator component.

Port Security Concepts 233 Chapter 5 RUGGEDCOM ROS Setup and Configuration User Guide

1 2 3 4

Figure 165: IEEE 802.1x General Topology 1. Supplicant 2. Authenticator Switch 3. LAN 4. Authentication Server

IMPORTANT! RUGGEDCOM ROS supports both Protected Extensible Authentication Protocol (PEAP) and EAP-MD5. PEAP is more secure and is recommended if available in the supplicant.

IEEE 802.1x makes use of the Extensible Authentication Protocol (EAP), which is a generic PPP authentication protocol that supports various authentication methods. IEEE 802.1x defines a protocol for communication between the Supplicant and the Authenticator, referred to as EAP over LAN (EAPOL). RUGGEDCOM ROS communicates with the Authentication Server using EAP over RADIUS.

NOTE The switch supports authentication of one host per port.

NOTE If the host’s MAC address is configured in the Static MAC Address Table, it will be authorized, even if the host authentication is rejected by the authentication server.

Section 5.9.1.3 IEEE 802.1X Authentication with MAC Address-Based Authentication

This method, also referred to as MAB (MAC-Authentication Bypass), is commonly used for devices, such as VoIP phones and Ethernet printers, that do not support the 802.1x protocol. This method allows such devices to be authenticated using the same database infrastructure as that used in 802.1x. IEEE 802.1x with MAC-Authentication Bypass works as follows: 1. The device connects to a switch port. 2. The switch learns the device MAC address upon receiving the first frame from the device (the device usually sends out a DHCP request message when first connected). 3. The switch sends an EAP Request message to the device, attempting to start 802.1X authentication. 4. The switch times out while waiting for the EAP reply, because the device does not support 802.1x. 5. The switch sends an authentication message to the authentication server, using the device MAC address as the username and password. 6. The switch authenticates or rejects the device according to the reply from the authentication server.

IEEE 802.1X Authentication with MAC Address-Based 234 Authentication RUGGEDCOM ROS Chapter 5 User Guide Setup and Configuration

Section 5.9.1.4 Assigning VLANS with Tunnel Attributes

RUGGEDCOM ROS supports assigning a VLAN to the authorized port using tunnel attributes, as defined in RFC 3580 [http://tools.ietf.org/html/rfc3580], when the Port Security mode is set to 802.1x or 802.1x/MAC-Auth. In some cases, it may be desirable to allow a port to be placed into a particular VLAN, based on the authentication result. For example: • To allow a particular device, based on its MAC address, to remain on the same VLAN as it moves within a network, configure the switches for 802.1X/MAC-Auth mode • To allow a particular user, based on the user’s login credentials, to remain on the same VLAN when the user logs in from different locations, configure the switches for 802.1X mode If the RADIUS server wants to use this feature, it indicates the desired VLAN by including tunnel attributes in the Access-Accept message. The RADIUS server uses the following tunnel attributes for VLAN assignment: • Tunnel-Type=VLAN (13) • Tunnel-Medium-Type=802 • Tunnel-Private-Group-ID=VLANID Note that VLANID is 12-bits and takes a value between 1 and 4094, inclusive. The Tunnel-Private-Group-ID is a string as defined in RFC 2868 [http://tools.ietf.org/html/rfc2868], so the VLANID integer value is encoded as a string. If the tunnel attributes are not returned by the authentication server, the VLAN assigned to the switch port remains unchanged.

Section 5.9.2 Viewing a List of Authorized MAC Addresses

To view a list of static MAC addresses learned from secure ports, navigate to Network Access Control » Port Security » View Authorized MAC Addresses . The Authorized MAC Addresses table appears.

NOTE Only MAC addresses authorized on a static MAC port(s) are shown. MAC addresses authorized with IEEE 802.1X are not shown.

Figure 166: Authorized MAC Addresses Table

This table displays the following information:

Parameter Description

Port Synopsis: 1 to maximum port number Port on which MAC address has been learned.

Assigning VLANS with Tunnel Attributes 235 Chapter 5 RUGGEDCOM ROS Setup and Configuration User Guide

Parameter Description

MAC Address Synopsis: ##-##-##-##-##-## where ## ranges 0 to FF Authorized MAC address learned by the switch.

VID Synopsis: 0 to 65535 VLAN Identifier of the VLAN upon which the MAC address operates.

Sticky Synopsis: { No, Yes } This describes whether the authorized MAC address/Device can move to another port or not: • YES - authorized MAC address/Device cannot move to a different switch port • NO - authorized MAC address/Device may move to another switch port

If a MAC address is not listed, do the following: • Configure port security. For more information, refer to Section 5.9.3, “Configuring Port Security” . • Configure IEEE 802.1X. For more information, refer to Section 5.9.4, “Configuring IEEE 802.1X” .

Section 5.9.3 Configuring Port Security

To configure port security, do the following: 1. Navigate to Network Access Control » Port Security » Configure Ports Security . The Ports Security table appears.

Figure 167: Ports Security Table

2. Select an Ethernet port. The Ports Security form appears.

236 Configuring Port Security RUGGEDCOM ROS Chapter 5 User Guide Setup and Configuration

1

2

3

4

5

6

7 8

Figure 168: Ports Security Form 1. Port Box 2. Security List 3. Autolearn Box 4. Sticky Options 5. Shutdown Time Box 6. Status Box 7. Apply Button 8. Reload Button

3. Configure the following parameter(s) as required:

Parameter Description

Port Synopsis: 1 to maximum port number Default: 1 The port number as seen on the front plate silkscreen of the switch.

Security Synopsis: { Off, Static MAC, 802.1X, 802.1x/MAC-Auth } Default: Off Enables or disables the port's security feature. Two types of port access control are available: • Static MAC address-based. With this method, authorized MAC address(es) should be configured in the Static MAC Address table. If some MAC addresses are not known in advance (or it is not known to which port they will be connected), there is still an option to configure the switch to auto-learn certain number of MAC addresses. Once learned, they do not age out until the unit is reset or the link goes down. • IEEE 802.1X standard authentication. • IEEE 802.1X with MAC-Authentication, also known as MAC- Authentication Bypass. With this option, the device can authenticate clients based on the client’s MAC address if IEEE 802.1X authentication times out.

Autolearn Synopsis: 1 to 16 or { None } Default: None Only applicable when the 'Security' field has been set to 'Static MAC'. It specifies maximum number of MAC addresses that can be dynamically learned on the port. If there are static addresses configured on the port, the actual number of addresses allowed to be learned is this number minus the number of the static MAC addresses.

Sticky Synopsis: { No, Yes } Default: Yes

Configuring Port Security 237 Chapter 5 RUGGEDCOM ROS Setup and Configuration User Guide

Parameter Description Only applicable when the 'Security' field has been set to 'Static MAC'. Change the behaviour of the port to either sticky or non- sticky. If Sticky is 'Yes', MACs/Devices authorized on the port 'stick' to the port and the switch will not allow them to move to a different port. If Sticky is 'No', MACs/Devices authorized on the port may move to another port.

Shutdown Time Synopsis: 1 to 86400 s or { Until reset, Don't shutdown } Default: Don't shutdown Specifies for how long to shut down the port, if a security violation occurs.

Status Synopsis: Any 31 characters Describes the security status of the port.

NOTE There are a few scenarios in which static MAC addresses can move: • When the link is up/down on a non-sticky secured port • When traffic switches from or to a non-sticky secured port

NOTE Traffic is lost until the source MAC Address of the incoming traffic is authorized against the static MAC address table.

4. Click Apply.

Section 5.9.4 Configuring IEEE 802.1X

To configure IEEE 802.1X port-based authentication, do the following: 1. Navigate to Network Access Control » Port Security » Configure 802.1X . The 802.1X Parameters table appears.

238 Configuring IEEE 802.1X RUGGEDCOM ROS Chapter 5 User Guide Setup and Configuration

Figure 169: 802.1X Parameters Table

2. Select an Ethernet port. The 802.1X Parameters form appears.

1

2

3

4

5

6

7

8

9

10 11

Figure 170: 802.1X Parameters Form 1. Port Box 2. tX Period Box 3. quietPeriod Box 4. reAuthEnabled Options 5. reAuthPeriod Box 6. reAuthMax Box 7. suppTimeout Box 8. serverTimeout Box 9. maxReq Box 10. Apply Button 11. Reload Button

3. Configure the following parameter(s) as required:

Parameter Description

Port Synopsis: 1 to maximum port number Default: 1 The port number as seen on the front plate silkscreen of the switch.

txPeriod Synopsis: 1 to 65535 Default: 30 s The time to wait for the Supplicant's EAP Response/Identity packet before retransmitting an EAP Request/Identity packet.

Configuring IEEE 802.1X 239 Chapter 5 RUGGEDCOM ROS Setup and Configuration User Guide

Parameter Description

quietPeriod Synopsis: 0 to 65535 Default: 60 s The period of time not to attempt to acquire a Supplicant after the authorization session failed.

reAuthEnabled Synopsis: { No, Yes } Default: No Enables or disables periodic re-authentication.

reAuthPeriod Synopsis: 60 to 86400 Default: 3600 s The time between periodic re-authentication of the Supplicant.

reAuthMax Synopsis: 1 to 10 Default: 2 The number of re-authentication attempts that are permitted before the port becomes unauthorized.

suppTimeout Synopsis: 1 to 300 Default: 30 s The time to wait for the Supplicant's response to the authentication server's EAP packet.

serverTimeout Synopsis: 1 to 300 Default: 30 s The time to wait for the authentication server's response to the Supplicant's EAP packet.

maxReq Synopsis: 1 to 10 Default: 2 The maximum number of times to retransmit the authentication server's EAP Request packet to the Supplicant before the authentication session times out.

4. Click Apply.

Section 5.10 Managing Link Aggregation

Link aggregation, also referred to as port trunking or port bundling, provides the ability to aggregate or gather several Ethernet ports into one logical link (port trunk) with higher bandwidth. This allows for highly randomized load balancing between the aggregated links based on both the source and destination MAC addresses of the forwarded frames. Link Aggregation can be used for two purposes: • To obtain increased, linearly incremental link bandwidth. • To improve network reliability by creating link redundancy. If one of the aggregated links fails, the switch will balance the traffic between the remaining links.

240 Managing Link Aggregation RUGGEDCOM ROS Chapter 5 User Guide Setup and Configuration

1 2

Figure 171: Examples of Link Aggregation 1. Switch 2. Server

RUGGEDCOM ROS allows up to 15 port trunks to be configured on a single device, with each consisting of up to 8 ports.

NOTE The maximum number of port trunks for each device depends on the number of ports available. At least two ports are required to configure a port trunk.

NOTE The aggregated port with the lowest port number is called the Port Trunk Primary Port. Other ports in the trunk are called Secondary Ports.

CONTENTS • Section 5.10.1, “Link Aggregation Concepts” • Section 5.10.2, “Managing Port Trunks”

Section 5.10.1 Link Aggregation Concepts

The following section describes some of the concepts important to the implementation of link aggregation in RUGGEDCOM ROS.

CONTENTS • Section 5.10.1.1, “Rules and Limitations”

Link Aggregation Concepts 241 Chapter 5 RUGGEDCOM ROS Setup and Configuration User Guide

• Section 5.10.1.2, “Link Aggregation and Layer 2 Features” • Section 5.10.1.3, “Link Aggregation and Physical Layer Features”

Section 5.10.1.1 Rules and Limitations

The implementation of link aggregation must adhere to the following rules and limitations: • Each port can belong to only one port trunk at a time. • A port mirroring target port can not be member of a port trunk. However, a port mirroring source port can be member of a port trunk. • If only one QinQ port is supported by the switch, the port working in QinQ mode cannot be a secondary member of a port trunk. • DHCP Relay Agent Client port cannot be a member of a port trunk. • Load balancing between the links of a bundle is randomized and may not be ideal. For instance, if three 100 Mbs links are aggregated, the resulting bandwidth of the port trunk may not be precisely 300 Mbs. • A Static MAC Address should not be configured to reside on an aggregated port – it may cause some frames destined for that address to be dropped. • A secure port cannot be a member of a port trunk. • The IEEE 802.3ad Link Aggregation standard requires all physical links in the port trunk to run at the same speed and in full-duplex mode. If this requirement is violated, the performance of the port trunk will drop. The switch will raise an appropriate alarm, if such a speed/duplex mismatch is detected. • STP dynamically calculates the path cost of the port trunk based on its aggregated bandwidth. However, if the aggregated ports are running at different speeds, the path cost may not be calculated correctly. • Enabling STP is the best way for handling link redundancy in switch-to-switch connections composed of more than one physical link. If STP is enabled and increased bandwidth is not required, Link Aggregation should not be used because it may lead to a longer fail-over time.

Section 5.10.1.2 Link Aggregation and Layer 2 Features

Layer 2 features (e.g. STP, VLAN, CoS, Multicast Filtering) treat a port trunk as a single link. • If the Spanning Tree Protocol (STP) puts an aggregated port in blocking/forwarding, it does it for the whole port trunk. • If one of the aggregated ports joins/leaves a multicast group (e.g. via IGMP or GMRP), all other ports in the trunk will join/leave too. • Any port configuration parameter (e.g. VLAN, CoS) change will be automatically applied to all ports in the trunk. • Configuration/status parameters of the secondary ports will not be shown and their port numbers will be simply listed next to the primary port number in the appropriate configuration/status UI sessions. • When a secondary port is added to a port trunk, it inherits all the configuration settings of the primary port. When this secondary port is removed from the port trunk, the settings it had previous to the aggregation are restored.

242 Rules and Limitations RUGGEDCOM ROS Chapter 5 User Guide Setup and Configuration

Section 5.10.1.3 Link Aggregation and Physical Layer Features

Physical layer features (e.g. physical link configuration, link status, rate limiting, Ethernet statistics) will still treat each aggregated port separately. • Physical configuration/status parameters will NOT be automatically applied to other ports in the trunk and will be displayed for each port as usual. • Make sure that only ports with the same speed and duplex settings are aggregated. If auto-negotiation is used, make sure it is resolved to the same speed for all ports in the port trunk. • To get a value of an Ethernet statistics counter for the port trunk, add the values of the counters for all ports in the port trunk.

Section 5.10.2 Managing Port Trunks

The following section describes how to configure and manage port trunks.

CONTENTS • Section 5.10.2.1, “Viewing a List of Port Trunks” • Section 5.10.2.2, “Adding a Port Trunk” • Section 5.10.2.3, “Deleting a Port Trunk”

Section 5.10.2.1 Viewing a List of Port Trunks

To view a list of port trunks configured on the device, navigate to Link Aggregation » Configure Port Trunks . The Port Trunks table appears.

Figure 172: Port Trunks Table

If port trunks have not been configured, add trunks as needed. For more information, refer to Section 5.10.2.2, “Adding a Port Trunk” .

Link Aggregation and Physical Layer Features 243 Chapter 5 RUGGEDCOM ROS Setup and Configuration User Guide

Section 5.10.2.2 Adding a Port Trunk

To add a port trunk, do the following:

IMPORTANT! The port trunk must be properly configured on both sides of the aggregated link. In switch-to-switch connections, if the configuration of both sides does not match (i.e. some ports are mistakenly not included in the port trunk), it will result in a loop. Therefore, the following procedure is strongly recommended to configure a port trunk: a. Disconnect or disable all the ports involved in the configuration, i.e. either being added to or removed from the port trunk. b. Configure the port trunk on both switches. c. Double-check the port trunk configuration on both switches. d. Reconnect or re-enable the ports. If the port trunk is being configured while the ports are not disconnected or disabled, the port will be automatically disabled for a few seconds.

1. Navigate to Link Aggregation » Configure Port Trunks . The Port Trunks table appears.

Figure 173: Port Trunks Table 1. InsertRecord

2. Click InsertRecord. The Port Trunks form appears.

1

2

3

4 6

5

Figure 174: Port Trunks 1. Trunk ID Box 2. Trunk Name Box 3. Ports Box 4. Apply Button 5. Delete Button 6. Reload Button

244 Adding a Port Trunk RUGGEDCOM ROS Chapter 5 User Guide Setup and Configuration

3. Configure the following parameter(s) as required:

Parameter Description

Trunk ID Synopsis: 1 to 2 Default: 1 Trunk number. It doesn't affect port trunk operation in any way and is only used for identification.

Trunk Name Synopsis: Any 19 characters Provides a description of the aggregated link purpose.

Ports Synopsis: Any combination of numbers valid for this parameter Default: None List of ports aggregated in the trunk.

4. Click Apply.

Section 5.10.2.3 Deleting a Port Trunk

To delete a port trunk, do the following: 1. Navigate to Link Aggregation » Configure Port Trunks . The Port Trunks table appears.

Figure 175: Port Trunks Table

2. Select the port trunk from the table. The Port Trunks form appears.

Deleting a Port Trunk 245 Chapter 5 RUGGEDCOM ROS Setup and Configuration User Guide

1

2

3

4 6

5

Figure 176: Port Trunks Form 1. Trunk ID Box 2. Trunk Name Box 3. Ports Box 4. Apply Button 5. Delete Button 6. Reload Button

3. Click Delete.

246 Deleting a Port Trunk RUGGEDCOM ROS Chapter 6 User Guide Troubleshooting

Troubleshooting

This chapter describes troubleshooting steps for common issues that may be encountered when using RUGGEDCOM ROS or designing a network.

IMPORTANT! For further assistance, contact a Customer Service representative.

CONTENTS • Section 6.1, “General” • Section 6.2, “Ethernet Ports” • Section 6.3, “Spanning Tree” • Section 6.4, “VLANs”

Section 6.1 General

The following describes common problems.

Problem Solution

The switch is not responding to ping Is the switch being pinged through a router? If so, the switch gateway address must be attempts, even though the IP address and configured as well. The following figure illustrates the problem. gateway have been configured. The switch is receiving the ping because the LEDs are flashing and the device statistics are logging the pings. What is going on? 1 2 3

192.168.0.1 10.10.0.2

10.10.0.1 192.168.0.2

Figure 177: Using a Router As a Gateway 1. Work Station 2. Router 3. Switch

The router is configured with the appropriate IP subnets and will forward the ping from the workstation to the switch. When the switch responds, however, it will not know which of its interfaces to use in order to reach the workstation and will drop the response. Programming a gateway of 10.0.0.1 will cause the switch to forward unresolvable frames to the router. This problem will also occur if the gateway address is not configured and the switch tries to raise an SNMP trap to a host that is not on the local subnet.

General 247 Chapter 6 RUGGEDCOM ROS Troubleshooting User Guide

Section 6.2 Ethernet Ports

The following describes common problems related to Ethernet ports.

Problem Solution

A link seems fine when traffic levels are low, A possible cause of intermittent operation is that of a ‘duplex mismatch’. If one end of the but fails as traffic rates increase OR a link can link is fixed to full-duplex and the peer auto-negotiates, the auto-negotiating end falls back be pinged but has problems with FTP/SQL/ to half-duplex operation. HTTP/etc. At lower traffic volumes, the link may display few if any errors. As the traffic volume rises, the fixed negotiation side will begin to experience dropped packets while the auto- negotiating side will experience collisions. Ultimately, as traffic loads approach 100%, the link will become entirely unusable. The ping command with flood options is a useful tool for testing commissioned links. The command ping 192.168.0.1 500 2 can be used to issue 500 pings each separated by two milliseconds to the next switch. If the link used is of high quality, then no pings should be lost and the average round trip time should be small.

Links are inaccessible, even when using the Make sure LFI is not enabled on the peer as well. If both sides of the link have LFI enabled, Link Fault Indication (LFI) protection feature. then both sides will withhold link signal generation from each other.

Section 6.3 Spanning Tree

The following describes common problems related to the Spanning Tree Protocol (STP).

Problem Solution

The network locks up when a new port is Is it possible that one of the switches in the network or one of the ports on a switch in the connected and the port status LEDs are network has STP disabled and accidentally connects to another switch? If this has occurred, flashing rapidly. then a traffic loop has been formed. If the problem appears to be transient in nature, it is possible that ports that are part of the Occasionally, the ports seem to experience spanning tree have been configured as edge ports. After the link layers have come up on significant flooding for a brief period of time. edge ports, STP will directly transition them (perhaps improperly) to the forwarding state. A switch displays a strange behavior where If an RSTP configuration message is then received, the port will be returned to blocking. A the root port hops back and forth between traffic loop may be formed for the length of time the port was in forwarding. two switch ports and never settles down. If one of the switches appears to flip the root from one port to another, the problem may be one of traffic prioritization. For more information refer to "The network becomes unstable when a specific application is started." Another possible cause of intermittent operation is that of an auto-negotiation mismatch. If one end of the link is fixed to full-duplex mode and the peer auto-negotiates, the auto- negotiating end will fall back to half-duplex operation. At lower traffic, the volumes the link may display few if any errors. As the traffic volume rises, the fixed negotiation side will begin to experience dropped packets while the auto-negotiating side will experience collisions. Ultimately, as traffic loads approach 100%, the link will become entirely unusable. At this point, RSTP will not be able to transmit configuration messages over the link and the spanning tree topology will break down. If an alternate trunk exists, RSTP will activate it in the place of the congested port. Since activation of the alternate port often relieves the congested port of its traffic, the congested port will once again become reliable. RSTP will promptly enter it back into service, beginning the cycle once again. The root port will flip back and forth between two ports on the switch.

A computer or device is connected to a Is it possible that the RSTP edge setting for this port is set to false? If Edge is set to false, the switch. After the switch is reset, it takes a bridge will make the port go through two forward delay times before the port can send or long time for it to come up. receive frames. If Edge is set to true, the bridge will transition the port directly to forwarding upon link up.

248 Ethernet Ports RUGGEDCOM ROS Chapter 6 User Guide Troubleshooting

Problem Solution Another possible explanation is that some links in the network run in half-duplex mode. RSTP uses a peer-to-peer protocol called Proposal-Agreement to ensure transitioning in the event of a link failure. This protocol requires full-duplex operation. When RSTP detects a non-full duplex port, it cannot rely on Proposal-Agreement protocol and must make the port transition the slow (i.e. STP) way. If possible, configure the port for full-duplex operation. Otherwise, configure the port’s point-to-point setting to true. Either one will allow the Proposal-Agreement protocol to be used.

When the switch is tested by deliberately Is it possible that some ports participating in the topology have been configured to STP mode breaking a link, it takes a long time before or that the port’s point-to-point parameter is set to false? STP and multipoint ports converge devices beyond the switch can be polled. slowly after failures occur. Is it possible that the port has migrated to STP? If the port is connected to the LAN segment by shared media and STP bridges are connected to that media, then convergence after link failure will be slow. Delays on the order of tens or hundreds of milliseconds can result in circumstances where the link broken is the sole link to the root bridge and the secondary root bridge is poorly chosen. The worst of all possible designs occurs when the secondary root bridge is located at the farthest edge of the network from the root. In this case, a configuration message will have to propagate out to the edge and then back in order to reestablish the topology.

The network is composed of a ring of A properly operating unmanaged bridge is transparent to STP configuration messages. The bridges, of which two (connected to managed bridges will exchange configuration messages through the unmanaged bridge each other) are managed and the rest are part of the ring as if it is non-existent. When a link in the unmanaged part of the ring fails unmanaged. Why does the RSTP protocol however, the managed bridges will only be able to detect the failure through timing out of work quickly when a link is broken between hello messages. Full connectivity will require three hello times plus two forwarding times to the managed bridges, but not in the be restored. unmanaged bridge part of the ring?

The network becomes unstable when a RSTP sends its configuration messages using the highest possible priority level. If CoS is specific application is started. The network configured to allow traffic flows at the highest priority level and these traffic flows burst returns to normal when the application is continuously to 100% of the line bandwidth, STP may be disrupted. It is therefore advised stopped. not to use the highest CoS.

When a new port is brought up, the root Is it possible that the port cost is incorrectly programmed or that auto-negotiation derives an moves on to that port instead of the port it undesired value? Inspect the port and path costs with each port active as root. should move to or stay on.

An Intelligent Electronic Device (IED) or Certain low CPU bandwidth controllers have been found to behave less than perfectly when controller does not work with the device. they receive unexpected traffic. Try disabling STP for the port. If the controller fails around the time of a link outage, there is the remote possibility that frame disordering or duplication may be the cause of the problem. Try setting the root port of the failing controller’s bridge to STP.

Polls to other devices are occassionally lost. Review the network statistics to determine whether the root bridge is receiving Topology Change Notifications (TCNs) around the time of observed frame loss. It may be possible there are problems with intermittent links in the network.

The root is receiving a number of TCNs. Examine the RSTP port statistics to determine the port from which the TCNs are arriving. Where are they coming from? Sign-on to the switch at the other end of the link attached to that port. Repeat this step until the switch generating the TCNs is found (i.e. the switch that is itself not receiving a large number of TCNs). Determine the problem at that switch.

Section 6.4 VLANs

The following describes common problems related to the VLANs.

VLANs 249 Chapter 6 RUGGEDCOM ROS Troubleshooting User Guide

Problem Solution

VLANs are not needed on the network. Can Yes. Simply leave all ports set to type edge and leave the native VLAN set to 1. This is the they be turned off? default configuration for the switch.

Two VLANs were created and a number of If the devices need to communicate at the physical address layer, they must be members of ports were made members of them. Now the same VLAN. If they can communicate in a Layer 3 fashion (i.e. using a protocol such as IP some of the devices in one VLAN need to or IPX), use a router. The router will treat each VLAN as a separate interface, which will have send messages to devices in the other VLAN. its own associated IP address space.

On a network of 30 switches, management At the switch where the management station is located, configure a port to use the new traffic needs to be restricted to a separate management VLAN as its native VLAN. Configure a host computer to act as a temporary domain. What is the best method for doing management station. this while staying in contact with these At each switch, configure the management VLAN to the new value. Contact with each switches? individual switch will be lost immediately as they are being configured, but it should be possible re-establish communication from the temporary management station. After all switches have been taken to the new management VLAN, configure the ports of all attached management devices to use the new VLAN.

NOTE Establishing a management domain is often accompanied with the establishment of an IP subnet specifically for the managed devices.

250 VLANs