Digital Radiography in Industry: Digital Detector Arrays in Radiographic Testing by Brad Kraai

Total Page:16

File Type:pdf, Size:1020Kb

Digital Radiography in Industry: Digital Detector Arrays in Radiographic Testing by Brad Kraai Vol. 15,13, No. 31 FOCUS Digital Radiography in Industry: Digital Detector Arrays in Radiographic Testing by Brad Kraai Introduction This article explores DDA systems: application, capability, process controls, Digital detector array (DDA) systems CONTENTS image attributes and evaluation, and within industrial radiography are becoming personnel qualifications—to hopefully Focus: very common in high performance, critical Digital Radiography in Industry ....... 1 promote an increased interest and margin of safety, and endurance test enlightenment for potential users. FYI: Hydrophilic Emulsifier article inspections. Investment castings, Concentration ................................. 8 thermal joints, and a wide variety of other Definitions NDT Professional test articles are being routinely inspected, Per ASTM E 2736, Standard Guide for Connections ................................ 12 with improved probability of detection Digital Detector Array Radiology, a digital (POD), and much faster throughput Practitioner Profile: detector array is defined as: “an electronic than conventional film systems—with Brad Remmich ............................. 14 device that converts ionizing or penetrating high levels of user satisfaction. Potential radiation into a discrete array of analog users within the industrial X-ray imaging signals which are subsequently digitized community continue to recognize these and transferred to a computer for display values and exploit this new technology as a digital image corresponding to the for potential applications, but to do so, radiation energy pattern imparted upon the a basic understanding of DDA systems input region of the device. The conversion and application is a necessary foundation. of the ionizing or penetrating radiation Smooth implementation of this novel into an electronic signal may transpire by technology can be challenging, and first converting the ionizing or penetrating consultation should be considered from an radiation into visible light through the use outside, unbiased, reputable organization. of a scintillating material” (ASTM, 2010a). There are several integrators, or vendors, While DDAs can be used for real-time or that are widely recognized as providers of radioscopic techniques, most applications The American Society for DDA systems development, installation, for critical test articles employ static Nondestructive Testing and service—each having its own merits www.asnt.org imaging and evaluation. Figure 1 provides and specialties. a simplified diagram of a DDA. ASNT...CREATING A SAFER WORLD!TM TNT · July 2016 · 1 FOCUS | Digital Radiography in Industry the responsibility of the potential user, not the integrator or vendor, to ensure that DDA system performance metrics are met for a given target application. X-ray signal Obviously, DDA systems are a considerable capital expenditure, so once the system is designed, built, and installed, it must Test article meet the requirements—resolve the defects reliably—as intended. This cannot be overemphasized. Film images are commonly used as the baseline or referee for a correlation study with the DDA imaging techniques, and will often be Electronics shielding (reduces radiation dose to electronics) required for process approval. Gadolinium oxysulfide or cesium iodide (converts X-ray signal to light signal) High levels of automation are possible Digital data to Amorphous silicon TFT (converts light signal to electronic signals) frame buffer and often used with DDAs. Imaging, from Electronics (captures electronic signals, organizes and converts to digital data) one acquisition to the next, can be mere Glass substrate (stable TFT and electronics structure base) seconds, depending on the type of DDA and acquisition settings, technique, and Figure 1. Simplified diagram of a digital detector array (not to scale). TFT = thin film transistor. level of automation. Fully articulating and programmable robotics within custom- built radiation enclosures are becoming The most popular types of DDAs in use raw or full fidelity image is saved unaltered quite common in turbine blade inspection; contain an initial and indirect conversion for critical applications. Raw image file size a single blade can be imaged with several layer (or scintillator)—typically either primarily depends on the resolution, or views in less than a minute. Other gadolinium oxysulfide terbium doped, pixel pitch, and input region (or array size) automation tactics may include external or cesium iodide thallium doped—that of the DDA, as well as its bit depth. ingress of test articles into the enclosure by converts an X-ray signal to visible light As one can see, DDAs are quite conveyors, or manual loading of numerous or luminescence. This luminescence then sophisticated electronic conversion parts in fixtures or platens. DDA systems enters the amorphous silicon (αSi) thin devices. Yet, they can provide simplicity with turntables for the test article and a film transistor diode array (discrete pixel to the radiographic imaging process, as C-arm—with the X-ray tube on one end locations), whereby the light is converted to consistency and reliability are often the and DDA on the other—are commonly an electronic voltage (bias change) at each result of a properly engineered, tuned, and used for larger test articles. Other pixel, which is subsequently “read out” of applied DDA system. sophisticated systems have incorporated the array in channels and groups during Applications two robots: one for the X-ray tube and the X-ray exposure. This electronic information other for the DDA, while the test article is amplified and then digitized, typically For the purpose of application validation, a remains stationary. System integrators can through several analog-to-digital converters, potential user must evaluate “representative be creative, and depending on the target synchronized, and sent to the frame buffer quality indicators,” or, more simply application, will often readily collaborate within the image processor and system stated, potential test articles with known with the potential user to design and software. conditions or defects (of a minimum size incorporate optimized article handling and Gray values for each pixel’s digital and all types likely to be encountered) for imaging for the intended application. (binary) value are then assigned by a lookup any DDA system under consideration. It must be realized that DDAs are in table, and a corresponding pixel matrix Quite often, DDA systems are designed fact a consumable, and will eventually that represents X-ray attenuation from the and built around a target application or require replacement due to performance initial image acquisition is generated and family: the potential test articles to be issues or degradation. They will and do considered as the raw or full fidelity image inspected with the DDA system will all fail (unpredictably, in most cases) over file. This image file also contains meta-data, be related—similar in material type and time. The cumulative effects of radiation or image tags of process information as material thickness, subject contrast range, exposure and thermal variations within configured by the system integrator. The and inspection standard criteria. It is the device produce effects that may range 2 · Vol. 15, No. 3 from image quality degradation all the resolutions (discrete pixel dimensions recommended 3 × 3 pixel matrix in the way to failure. ere are no guarantees or “pixel pitch”) currently available, the IQI hole decreases in turn. Higher M of a DDA’s usable duration. Inadvertent contrast sensitivity for these devices is factors increase pixel density for a speci c or unintentional exposure to the DDA remarkable—provided noise is controlled. dimension within the image, thereby should be avoided. Recent developments in Due to inherent DDA resolution, promoting higher POD. Higher M factors hardened electronics have increased DDA geometric magni cation (M) techniques applied within techniques will decrease the resistance to exposure e ects. Shielding are often employed, which amplify image eld of view, resulting in decreased of the electronics around the periphery discontinuity size and enhance POD throughput for larger test articles as of the DDA must be provided by the via a higher number of pixels under the compared to the DDA input region. integrator, and should be analyzed by the potential discontinuity or feature within Another primary consideration for any DDA manufacturer for warranty viability. the test article. It is a relatively simple geometrically magni ed technique is image Moreover, users of DDA systems must matter to calculate for a speci c number unsharpness (Uimg), wherein a reduced contemplate detector failure or sub-par of pixels under a known dimension at e ective focal spot size (EFSS) is often imaging contingency and warranty when geometric magni cation, and quite often, necessary at higher magni cations. Uimg negotiating procurement. the calculation is applied to determine calculations take into account the As mentioned previously, the DDA pixel density within an essential image geometric unsharpness (Ug) of the and its supportive software are very quality indicator (IQI) hole dimension. technique, (where [M – 1] × EFSS = Ug), complex. is DDA system complexity e minimum recommendation is three the geometric magni cation factor can be very intimidating, so a word of pixels, so by using the basic spatial (M = source-to-detector distance / source- advice: complexity of the entire DDA
Recommended publications
  • Radiology Physics Lectures: Digital Radiography
    Radiology Physics Lectures: Digital Radiography Digital Radiography D. J. Hall, Ph.D. x20893 [email protected] Radiology Physics Lectures: Digital Radiography Background • Common Digital Modalities – Digital Chest Radiograph - 4096 x 4096 x 12 bit – CT - 512 x 512 x 12 bit – SPECT - 128 x 128 x 8 bit – MRI - 256 x 256 x 8 bit – US - 512 x 512 x 8 or 24 bits • Viewing Station – 2k x 2k x 12 bits Radiology Physics Lectures: Digital Radiography Computed Radiography • Photostimulable phosphor – Energy trapped on plate – Readout at later time – BaFBr or BaFI – Flexible plate stored in cassette – Exposed to x-rays like film – Processed in special reader Radiology Physics Lectures: Digital Radiography Computed Radiography • Photostimulable phosphor - readout Radiology Physics Lectures: Digital Radiography Computed Radiography Reader Radiology Physics Lectures: Digital Radiography Computed Radiography - emission wavelengths Radiology Physics Lectures: Digital Radiography Computed Radiography - How it works! Radiology Physics Lectures: Digital Radiography Computed Radiography - Dynamic Range Radiology Physics Lectures: Digital Radiography Charge Coupled Devices • Make images from visible light • Made of Silicon • Visible light liberates electrons – Electrons accumulate in individual pixel cells • Accumulated charge readout pixel by pixel • Requires coupling between light source and CCD • Used for fluoroscopy and cine-angiography • Large FOV imaging loses light – Proportional to areas of CCD and light source Radiology Physics Lectures: Digital Radiography
    [Show full text]
  • Digital and Advanced Imaging Equipment
    CHAPTER 9 Digital and Advanced Imaging Equipment KEY TERMS active matrix array direct-to-digital radiographic systems photostimulated luminescence amorphous dual-energy x-ray absorptiometry picture archiving and communication analog-to-digital converter F-center system aspect ratio fill factor preprocessing cinefluorography frame rate postprocessing computed radiography image contrast refresh rate detective quantum efficiency image enhancement special procedures laboratory Digital Imaging and Communications image management and specular reflection in Medicine group communication system teleradiology digital fluoroscopy image restoration thin-film transistor digital radiography interpolation window level digital subtraction angiography liquid crystal display window width digital x-ray radiogrammetry Nyquist frequency OBJECTIVES At the completion of this chapter the reader should be able to do the following: • Describe the basic methods of obtaining digital cathode-ray tube cameras, videotape and videodisc radiographs recorders, and cinefluorographic equipment and discuss • State the advantages and disadvantages of digital the quality control procedures for each radiography versus conventional film/screen • Describe the various types of electronic display devices radiography and discuss the applicable quality control procedures • Discuss the quality control procedures for evaluating • Explain the basic image archiving and management digital radiographic systems networks and discuss the applicable quality control • Describe the basic methods
    [Show full text]
  • Basic Knowledge and New Advances in Panoramic Radiography Imaging Techniques: a Narrative Review on What Dentists and Radiologists Should Know
    applied sciences Review Basic Knowledge and New Advances in Panoramic Radiography Imaging Techniques: A Narrative Review on What Dentists and Radiologists Should Know Rossana Izzetti 1 , Marco Nisi 1, Giacomo Aringhieri 2, Laura Crocetti 2, Filippo Graziani 1,* and Cosimo Nardi 3 1 Unit of Dentistry and Oral Surgery, Department of Surgical, Medical and Molecular Pathology and Critical Care Medicine, University of Pisa, 56126 Pisa, Italy; [email protected] (R.I.); [email protected] (M.N.) 2 Diagnostic and Interventional Radiology, Department of Translational Research and of New Technologies in Medicine and Surgery, University of Pisa, 56122 Pisa, Italy; [email protected] (G.A.); [email protected] (L.C.) 3 Radiodiagnostic Unit n. 2, Department of Experimental and Clinical Biomedical Sciences, University of Florence—Azienda Ospedaliero-Universitaria Careggi, Largo Brambilla 3, 50134 Florence, Italy; cosimo.nardi@unifi.it * Correspondence: fi[email protected] Abstract: Objectives: A panoramic radiograph (PAN) is the most frequently diagnostic imaging technique carried out in dentistry and oral surgery. The correct performance of image acquisition is crucial to obtain adequate image quality. The aim of the present study is to (i) review the principles of PAN image acquisition and (ii) describe positioning errors and artefacts that may affect PAN image quality. Methods: Articles regarding PAN acquisition principles, patient’s positioning errors, artefacts, and image quality were retrieved from the literature. Results: Head orientation is of the Citation: Izzetti, R.; Nisi, M.; utmost importance in guaranteeing correct image acquisition. Symmetry, occlusal plane inclination, Aringhieri, G.; Crocetti, L.; Graziani, F.; Nardi, C.
    [Show full text]
  • Central Council of Indian Medicine New Delhi
    CENTRAL COUNCIL OF INDIAN MEDICINE NEW DELHI SYLLABUS OF AYURVEDACHARYA (BAMS) COURSE INDEX 1ST PROFESSIONAL 1.1 PADARTHA VIGYAN AND AYURVED ITIHAS 2-6 1.2 SANSKRIT 7-8 1.3 KRIYA SHARIR 9-14 1.4 RACHANA SHARIR 15-18 1.5 MAULIK SIDDHANT AVUM ASTANG HRIDYA 19 Central Council of Indian Medicine |UG Ist year Syllabus 1 1.1 PADARTHA VIGYAN EVUM AYURVEDA ITIHAS (Philosophy and History of Ayurveda) Theory- Two papers– 200 marks (100 each paper) Total teaching hours: 150 hours PAPER-I Padartha Vigyanam 100marks PART A 50 marks 1.Ayurveda Nirupana 1.1 Lakshana of Ayu, composition of Ayu. 1.2 Lakshana of Ayurveda. 1.3 Lakshana and classification of Siddhanta. 1.4 Introduction to basic principles of Ayurveda and their significance. 2. Ayurveda Darshana Nirupana 2.1 Philosophical background of fundamentals of Ayurveda. 2.2 Etymological derivation of the word “Darshana”. Classification and general introduction to schools of Indian Philosophy with an emphasis on: Nyaya, Vaisheshika, Sankhya and Yoga. 2.3 Ayurveda as unique and independent school of thought (philosophical individuality of Ayurveda). 2.4 Padartha: Lakshana, enumeration and classification, Bhava and Abhava padartha, Padartha according to Charaka (Karana-Padartha). 3. Dravya Vigyaniyam 3.1 Dravya: Lakshana, classification and enumeration. 3.2 Panchabhuta: Various theories regarding the creation (theories of Taittiriyopanishad, Nyaya-Vaisheshika, Sankhya-Yoga, Sankaracharya, Charaka and Susruta), Lakshana and qualities of each Bhoota. 3.3 Kaala: Etymological derivation, Lakshana and division / units, significance in Ayurveda. 3.4 Dik: Lakshana and division, significance in Ayurveda. 3.5 Atma:Lakshana, classification, seat, Gunas, Linga according to Charaka, the method / process of knowledge formation (atmanah jnasya pravrittih).
    [Show full text]
  • Recommendations for Patient Selection and Limiting Radiation Exposure
    DENTAL RADIOGRAPHIC EXAMINATIONS: RECOMMENDATIONS FOR PATIENT SELECTION AND LIMITING RADIATION EXPOSURE REVISED: 2012 AMERICAN DENTAL ASSOCIATION Council on Scientific Affairs U.S. DEPARTMENT OF HEALTH AND HUMAN SERVICES Public Health Service Food and Drug Administration TABLE OF CONTENTS Background ............................................................................................................................ 1 Introduction ............................................................................................................................ 1 Patient Selection Criteria ...................................................................................................... 2 Recommendations for Prescribing Dental Radiographs ......................................... 5 Explanation of Recommendations for Prescribing Dental Radiographs ................ 8 New Patient Being Evaluated for Oral Diseases ............................................ 8 Recall Patient with Clinical Caries or Increased Risk for Caries ............... 11 Recall Patient (Edentulous Adult) ................................................................. 11 Recall Patient with No Clinical Caries and No Increased Risk for Caries . 11 Recall Patient with Periodontal Disease ...................................................... 12 Patient (New and Recall) for Monitoring Growth and Development .......... 13 Patients with Other Circumstances .............................................................. 14 Limiting Radiation Exposure .............................................................................................
    [Show full text]
  • Digital Radiography in Industry: Digital Detector Arrays in Radiographic Testing by Brad Kraai
    Vol. 15,13, No. 31 FOCUS Digital Radiography in Industry: Digital Detector Arrays in Radiographic Testing by Brad Kraai Introduction This article explores DDA systems: application, capability, process controls, Digital detector array (DDA) systems image attributes and evaluation, and within industrial radiography are becoming personnel qualifications—to hopefully very common in high performance, critical promote an increased interest and margin of safety, and endurance test enlightenment for potential users. article inspections. Investment castings, thermal joints, and a wide variety of other Definitions test articles are being routinely inspected, Per ASTM E 2736, Standard Guide for with improved probability of detection Digital Detector Array Radiology, a digital (POD), and much faster throughput detector array is defined as: “an electronic than conventional film systems—with device that converts ionizing or penetrating high levels of user satisfaction. Potential radiation into a discrete array of analog users within the industrial X-ray imaging signals which are subsequently digitized community continue to recognize these and transferred to a computer for display values and exploit this new technology as a digital image corresponding to the for potential applications, but to do so, radiation energy pattern imparted upon the a basic understanding of DDA systems input region of the device. The conversion and application is a necessary foundation. of the ionizing or penetrating radiation Smooth implementation of this novel into an electronic signal may transpire by technology can be challenging, and first converting the ionizing or penetrating consultation should be considered from an radiation into visible light through the use outside, unbiased, reputable organization. of a scintillating material” (ASTM, 2010a).
    [Show full text]
  • Best Practices in Digital Radiography
    WHITE PAPER Best Practices in Digital Radiography Daniel N. DeMaio, MEd, R.T.(R)(CT); Tracy Herrmann, PhD, R.T.(R); Lauren B. Noble, EdD, R.T.(R); Denise Orth, MS, R.T.(R)(M); Paulette Peterson, MEd, R.T.(R)(M)(QM); Jason Young, BS, R.T.(R); Teresa G. Odle, BA, ELS Published by the American Society of Radiologic Technologists, 15000 Central Ave. SE, Albuquerque, NM 87123-3909. ©2019 American Society of Radiologic Technologists. All rights reserved. ASRT prohibits reprinting all or part of this document without advance written permission granted by this organization. Send reprint requests to ASRT. WHITE PAPER Best Practices in Digital Radiography Daniel N. DeMaio, MEd, R.T.(R)(CT); Tracy Herrmann, PhD, R.T.(R); Lauren B. Noble, EdD, R.T. (R); Denise Orth, MS, R.T.(R)(M); Paulette Peterson, MEd, R.T.(R)(M)(QM); Jason Young, BS, R.T. (R); Teresa G. Odle, BA, ELS eports on medical imaging use and resulting Digital imaging methods now are common across radiation exposure have increased following a all indications for and forms of radiography, including series of widely publicized incidents of exces- fluoroscopy and mammography. As radiographers have sive patient exposure to low levels of radiation adjusted to the widespread use of digital radiography, Rduring medical imaging examinations or procedures. they have had to refine exposure technique selection Increases in exposure initially were attributed to rising and pay closer attention to radiation protection. Digital utilization of medical imaging as technology has technologies offer many benefits for acquiring and post- improved the ability to diagnose and evaluate a wide processing images.
    [Show full text]
  • Comparison of Accuracy of Digital Radiography and Panoramic Radiography in Dental Implants Procedure - a Literature Review M
    Review Article Comparison of accuracy of digital radiography and panoramic radiography in dental implants procedure - A literature review M. Keerthna, Ashish R. Jain* ABSTRACT Appropriate treatment planning for replacement of lost teeth is required, and imaging plays an important role to ensure a beneficiary outcome that satisfies the patient desires and needs. Dental implants are gaining immense popularity and wide acceptance because they not only replace lost teeth but also provide permanent restorations that do not interfere with mastication or speech or compromise the self-esteem of a patient. Radiological examination is very necessary for evaluating the anatomy of the structures such as maxillary sinus, the mental foramen, and the inferior alveolar nerve canal in relation to the teeth that are to be replaced by implants. Cone beam computed tomography (CBCT) has been widely used in dental implanting. However, the local hospitals usually do not have access to CBCT due to the cost and medical investment. The doctors in local hospitals have to make reasonable dental planting using orthopantomography (OPG) to reduce risks. Therefore, it is clinically meaningful to determine the magnification rate of OPG to obtain correct diagnosis. KEY WORDS: Cephalometry, Cone beam computed tomography, Dental implants, Digital radiography, Orthopantomography INTRODUCTION implant placement, the anatomical structures in and around them are considered the crucial factor for Currently, the placements of oral implants are selecting the implants to be placed
    [Show full text]
  • A Comparison of Panoramic Image Quality Between a Digital Radiography Storage Phosphor System and a Film-Based System
    A Comparison of Panoramic Image Quality between a Digital Radiography Storage Phosphor System and a Film-Based System Nikos Parissis, DDS, PhD; Christos Angelopoulos, DDS, MS; Stephen Mantegari, DDS, MD; Stelios Karamanis, DDS; Farah Masood, DDS, MS; Anastasios Tsirlis, DDS, PhD Abstract Aim: To compare digital panoramic images acquired for the presurgical assessment of third molars captured with a storage phosphor- based system with conventional film panoramic radiographs. Methods and Materials: A total of 51 pairs of digital and conventional panoramic images, made simultaneously, were included in this study. The images were evaluated for diagnostic quality prior to third molar surgery by two experienced oral surgeons and rated with a four-point grading scale. Results: Despite the fact that conventional panoramic images were rated higher than the digital images, the difference was not statistically significant. Citation: Parissis N, Angelopoulos C, Mantegari Conclusions: Conventional and digital panoramic S, Karamanis S, Masood F, Tsirlis A. A images were found to be of comparable image Comparison of Panoramic Image Quality between quality with regard to their diagnostic contribution a Digital Radiography Storage Phosphor System to third molar surgery. and a Film-Based System. J Contemp Dent Pract [Internet]. 2010 Jan; 11(1):009-016. Available Clinical Significance: This study is contributory from: http://www.thejcdp.com/journal/view/ to understanding differences in image quality volume11-issue1-parissis. between digital and conventional panoramic radiography for certain diagnostic tasks. The lack of significant differences in image quality may be Introduction an endorsement for digital panoramic radiography. Panoramic radiography has been an invaluable Keywords: Digital radiography, panoramic diagnostic tool for the dental profession.
    [Show full text]
  • ACR–AAPM–SIIM-SPR Practice Parameter for Digital Radiography
    The American College of Radiology, with more than 30,000 members, is the principal organization of radiologists, radiation oncologists, and clinical medical physicists in the United States. The College is a nonprofit professional society whose primary purposes are to advance the science of radiology, improve radiologic services to the patient, study the socioeconomic aspects of the practice of radiology, and encourage continuing education for radiologists, radiation oncologists, medical physicists, and persons practicing in allied professional fields. The American College of Radiology will periodically define new practice parameters and technical standards for radiologic practice to help advance the science of radiology and to improve the quality of service to patients throughout the United States. Existing practice parameters and technical standards will be reviewed for revision or renewal, as appropriate, on their fifth anniversary or sooner, if indicated. Each practice parameter and technical standard, representing a policy statement by the College, has undergone a thorough consensus process in which it has been subjected to extensive review and approval. The practice parameters and technical standards recognize that the safe and effective use of diagnostic and therapeutic radiology requires specific training, skills, and techniques, as described in each document. Reproduction or modification of the published practice parameter and technical standard by those entities not providing these services is not authorized. Revised 2017 (Resolution 40)* ACR–AAPM–SIIM–SPR PRACTICE PARAMETER FOR DIGITAL RADIOGRAPHY PREAMBLE This document is an educational tool designed to assist practitioners in providing appropriate radiologic care for patients. Practice Parameters and Technical Standards are not inflexible rules or requirements of practice and are not intended, nor should they be used, to establish a legal standard of care1.
    [Show full text]
  • Digital Radiography Image Quality: Image Acquisition Mark B
    Digital Radiography Image Quality: Image Acquisition Mark B. Williams, PhDa, Elizabeth A. Krupinski, PhDb, Keith J. Strauss, MSc, William K. Breeden, III, MSd, Mark S. Rzeszotarski, PhDe, Kimberly Applegate, MD, MSf, Margaret Wyattg, Sandra Bjork, RN, JDg, J. Anthony Seibert, PhDh This article on digital radiography image acquisition is the first of two articles written as part of an intersociety effort to establish image quality standards for digital and computed radiography. The topic of the other paper is digital radiography image processing and display. The articles were developed collaboratively by the ACR, the American Association of Physicists in Medicine, and the Society for Imaging Informatics in Medicine. Increas- ingly, medical imaging and patient information are being managed using digital data during acquisition, transmission, storage, display, interpretation, and consultation. Data management during each of these oper- ations has a direct impact on the quality of patient care. These articles describe what is known to improve image quality for digital and computed radiography and make recommendations on optimal acquisition, processing, and display. The practice of digital radiography is a rapidly evolving technology that will require the timely revision of any guidelines and standards. This document provides a basis for the technologies available today in clinical practice and may be useful in guiding the future clinical practice of digital radiography. Key Words: Digital radiography, image quality, image acquisition J Am Coll Radiol 2007;4:371-388. Copyright © 2007 American College of Radiology INTRODUCTION AND DEFINITIONS There are several types of detectors that can be classified as DR systems, including automated (cassetteless) CR Computed radiography (CR) and digital radiography (DR) systems.
    [Show full text]
  • Technology Report No 30
    Digital Mammography Technology versus Film-Screen Mammography: Technical, Clinical Report and Economic Issue 30 October 2002 Assessments Publications can be requested from: CCOHTA 110-955 Green Valley Crescent Ottawa, Ontario, Canada K2C 3V4 Tel. (613) 226-2553 Fax. (613) 226-5392 Email: [email protected] or download from CCOHTA’s web site: http://www.ccohta.ca Cite as: Ho C, Hailey D, Warburton R, MacGregor J, Pisano E, Joyce J. Digital mammography versus film-screen mammography: technical, clinical and economic assessments. Ottawa: Canadian Coordinating Office for Health Technology Assessment; 2002. Technology report no 30. Reproduction of this document for non-commercial purposes is permitted provided appropriate credit is given to CCOHTA. Legal Deposit - 2002 National Library of Canada ISBN: 1-894620-62-3 (print) ISBN: 1-894620-61-5 (electronic version) Publications Mail Agreement Number: 40026386 Canadian Coordinating Office for Health Technology Assessment Digital Mammography versus Film-Screen Mammography: Technical, Clinical and Economic Assessments Chuong Ho MD MSc1 David Hailey PhD2 Rebecca Warburton PhD3 John H MacGregor MD4 Etta D Pisano MD FACR5 Janet Joyce MLS1 October 2002 1 Canadian Coordinating Office for Health Technology Assessment, Ottawa, Canada 2 Department of Public Health Sciences, University of Alberta, Edmonton, Canada 3 School of Public Administration, University of Victoria, Victoria, Canada 4 Department of Diagnostic Radiology, University of Calgary, Calgary, Canada 5 Departments of Radiology and Biomedical Engineering,
    [Show full text]