IBM Power System S821LC: Technical Overview and Introduction

Total Page:16

File Type:pdf, Size:1020Kb

IBM Power System S821LC: Technical Overview and Introduction Front cover IBM Power System S821LC Technical Overview and Introduction David Barron Alexandre Bicas Caldeira Volker Haug Redpaper International Technical Support Organization IBM Power System S821LC: Technical Overview and Introduction December 2016 REDP-5406-00 Note: Before using this information and the product it supports, read the information in “Notices” on page v. First Edition (December 2016) This edition applies to the IBM Power System S821LC (8001-12C) server. © Copyright International Business Machines Corporation 2016. All rights reserved. Note to U.S. Government Users Restricted Rights -- Use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp. Contents Notices . .v Trademarks . vi Preface . vii Authors. viii Now you can become a published author, too! . viii Comments welcome. ix Stay connected to IBM Redbooks . ix Chapter 1. Architecture and technical description . 1 1.1 Power S821LC system hardware overview . 2 1.2 System architecture . 4 1.3 Physical package . 6 1.4 Operating environment . 7 1.5 Leveraging innovations of the OpenPOWER Foundation. 7 1.6 Base system and standard features . 7 1.6.1 Power S821LC server minimum configuration . 8 1.7 Available features . 9 1.7.1 IBM POWER8 processor . 9 1.7.2 Memory . 18 1.7.3 Internal storage subsystems . 23 1.7.4 PCI adapters . 26 1.8 Operating system . 30 1.8.1 Ubuntu . 30 1.8.2 Red Hat Enterprise Linux . 31 1.9 IBM System Storage . 31 1.9.1 IBM Storwize family. 31 1.9.2 IBM FlashSystem family . 31 1.9.3 IBM XIV Storage System . 31 1.9.4 IBM System Storage DS8000 . 32 1.10 Java. 32 Chapter 2. Management and virtualization . 33 2.1 Main management components overview. 34 2.2 Service processor . 34 2.2.1 Open Power Abstraction Layer . 35 2.2.2 Intelligent Platform Management Interface . 35 2.2.3 Petitboot bootloader . 36 2.3 IBM Cloud PowerVC Manager . 36 2.3.1 Benefits . 36 2.3.2 Lifecycle . 37 Chapter 3. Reliability, availability, and serviceability. 39 3.1 Introduction . 40 3.1.1 RAS enhancements of POWER8 processor-based scale-out servers . 40 3.2 IBM terminology versus x86 terminology . 41 3.3 Error handling . 41 3.3.1 Processor core/cache correctable error handling . 41 3.3.2 Processor Instruction Retry and other try again techniques . 42 © Copyright IBM Corp. 2016. All rights reserved. iii 3.3.3 Other processor chip functions . 42 3.4 Serviceability . 42 3.4.1 Detection introduction . 43 3.4.2 Error checkers and fault isolation registers. 43 3.4.3 Service processor . 43 3.4.4 Diagnosing . 44 3.4.5 General problem determination. 44 3.4.6 Error handling and reporting . 45 3.4.7 Locating and servicing . 46 3.5 Manageability . 48 3.5.1 Service user interfaces . 48 3.5.2 IBM Power Systems firmware maintenance . 49 3.5.3 Updating the system firmware with the ipmitool command. 50 3.5.4 Updating the ipmitool on Ubuntu. 50 3.5.5 Statement of direction: Updating the system firmware by using the Advanced System Management console . 52 Appendix A. Server racks and energy management . 59 IBM server racks . 60 IBM 42U Slim Rack (7965-94Y) . 60 The AC power distribution unit and rack content . 60 Rack-mounting rules . 63 OEM racks . 63 Energy consumption estimation . 63 Related publications . 65 IBM Redbooks . 65 Online resources . ..
Recommended publications
  • Red Hat Enterprise Linux 6 Developer Guide
    Red Hat Enterprise Linux 6 Developer Guide An introduction to application development tools in Red Hat Enterprise Linux 6 Dave Brolley William Cohen Roland Grunberg Aldy Hernandez Karsten Hopp Jakub Jelinek Developer Guide Jeff Johnston Benjamin Kosnik Aleksander Kurtakov Chris Moller Phil Muldoon Andrew Overholt Charley Wang Kent Sebastian Red Hat Enterprise Linux 6 Developer Guide An introduction to application development tools in Red Hat Enterprise Linux 6 Edition 0 Author Dave Brolley [email protected] Author William Cohen [email protected] Author Roland Grunberg [email protected] Author Aldy Hernandez [email protected] Author Karsten Hopp [email protected] Author Jakub Jelinek [email protected] Author Jeff Johnston [email protected] Author Benjamin Kosnik [email protected] Author Aleksander Kurtakov [email protected] Author Chris Moller [email protected] Author Phil Muldoon [email protected] Author Andrew Overholt [email protected] Author Charley Wang [email protected] Author Kent Sebastian [email protected] Editor Don Domingo [email protected] Editor Jacquelynn East [email protected] Copyright © 2010 Red Hat, Inc. and others. The text of and illustrations in this document are licensed by Red Hat under a Creative Commons Attribution–Share Alike 3.0 Unported license ("CC-BY-SA"). An explanation of CC-BY-SA is available at http://creativecommons.org/licenses/by-sa/3.0/. In accordance with CC-BY-SA, if you distribute this document or an adaptation of it, you must provide the URL for the original version. Red Hat, as the licensor of this document, waives the right to enforce, and agrees not to assert, Section 4d of CC-BY-SA to the fullest extent permitted by applicable law.
    [Show full text]
  • IBM Flashsystem A9000 Product Guide (Version 12.3)
    Front cover IBM FlashSystem A9000 Product Guide (Updated for Version 12.3.2) Bert Dufrasne Stephen Solewin Francesco Anderloni Roger Eriksson Lisa Martinez Product Guide IBM FlashSystem A9000 Product Guide This IBM® Redbooks® Product Guide is an overview of the main characteristics, features, and technologies that are used in IBM FlashSystem® A9000 Models 425 and 25U, with IBM FlashSystem A9000 Software V12.3.2. IBM FlashSystem A9000 storage system uses the IBM FlashCore® technology to help realize higher capacity and improved response times over disk-based systems and other competing flash and solid-state drive (SSD)-based storage. FlashSystem A9000 offers world-class software features that are built with IBM Spectrum™ Accelerate. The extreme performance of IBM FlashCore technology with a grid architecture and comprehensive data reduction creates one powerful solution. Whether you are a service provider who requires highly efficient management or an enterprise that is implementing cloud on a budget, FlashSystem A9000 provides consistent and predictable microsecond response times and the simplicity that you need. As a cloud optimized solution, FlashSystem A9000 suits the requirements of public and private cloud providers who require features, such as inline data deduplication, multi-tenancy, and quality of service. It also uses powerful software-defined storage capabilities from IBM Spectrum Accelerate, such as Hyper-Scale technology, VMware, and storage container integration. FlashSystem A9000 is a modular system that consists of three grid controllers and a flash enclosure. An external view of the Model 425 is shown in Figure 1. Figure 1 IBM FlashSystem A9000 Model 425 © Copyright IBM Corp. 2017, 2018. All rights reserved.
    [Show full text]
  • IBM Power System POWER8 Facts and Features
    IBM Power Systems IBM Power System POWER8 Facts and Features April 29, 2014 IBM Power Systems™ servers and IBM BladeCenter® blade servers using IBM POWER7® and POWER7+® processors are described in a separate Facts and Features report dated July 2013 (POB03022-USEN-28). IBM Power Systems™ servers and IBM BladeCenter® blade servers using IBM POWER6® and POWER6+™ processors are described in a separate Facts and Features report dated April 2010 (POB03004-USEN-14). 1 IBM Power Systems Table of Contents IBM Power System S812L 4 IBM Power System S822 and IBM Power System S822L 5 IBM Power System S814 and IBM Power System S824 6 System Unit Details 7 Server I/O Drawers & Attachment 8 Physical Planning Characteristics 9 Warranty / Installation 10 Power Systems Software Support 11 Performance Notes & More Information 12 These notes apply to the description tables for the pages which follow: Y Standard / Supported Optional Optionally Available / Supported N/A or - Not Available / Supported or Not Applicable SOD Statement of General Direction announced SLES SUSE Linux Enterprise Server RHEL Red Hat Enterprise Linux a One x8 PCIe slots must contain a 4-port 1Gb Ethernet LAN available for client use b Use of expanded function storage backplane uses one PCIe slot Backplane provides dual high performance SAS controllers with 1.8 GB write cache expanded up to 7.2 GB with c compression plus Easy Tier function plus two SAS ports for running an EXP24S drawer d Full benchmark results are located at ibm.com/systems/power/hardware/reports/system_perf.html e Option is supported on IBM i only through VIOS.
    [Show full text]
  • Faster Oracle Performance with IBM Flashsystem 2 Faster Oracle Performance with IBM Flashsystem
    IBM Systems and Technology Group May 2013 Thought Leadership White Paper Faster Oracle performance with IBM FlashSystem 2 Faster Oracle performance with IBM FlashSystem Executive summary The result is a massive performance gap, felt most painfully This whitepaper discusses methods for improving Oracle® by database servers, which typically carry out far more I/O database performance using flash storage to accelerate the most transactions than other systems. Super fast processors and resource-intensive data that slows performance across the massive amounts of bandwidth are often wasted as storage board. devices take several milliseconds just to access the requested data. To this end, it discusses methods for identifying I/O performance bottlenecks, and it points out components that are the best candidates for migration to a flash storage appliance. An in-depth explanation of flash technology and possible implementations are also included. The problem of I/O wait time Often, additional processing power alone will do little or nothing to improve Oracle performance. This is because the processor, no matter how fast, finds itself constantly waiting on mechanical storage devices for its data. While every other component in the “data chain” moves in terms of computation times and the raw speed of electricity through a circuit, hard drives move mechanically, relying on physical movement around a magnetic platter to access information. In the last 20 years, processor speeds have increased at a Figure 1: Comparing processor and storage performance improvements geometric rate. At the same time, however, conventional storage access times have only improved marginally (see Figure 1). IBM Systems and Technololgy Group 3 When servers wait on storage, users wait on servers.
    [Show full text]
  • IBM DS8880: Hybrid Cloud Integration with Transparent Cloud Tiering
    Accelerate with IBM Storage: IBM DS8880: Hybrid cloud integration with Transparent Cloud Tiering Craig Gordon Consulting I/T Specialist IBM Washington Systems Center [email protected] © Copyright IBM Corporation 2018. Washington Systems Center - Storage Accelerate with IBM Storage Webinars The Free IBM Storage Technical Webinar Series Continues in 2018... Washington Systems Center – Storage experts cover a variety of technical topics. Audience: Clients who have or are considering acquiring IBM Storage solutions. Business Partners and IBMers are also welcome. To automatically receive announcements of upcoming Accelerate with IBM Storage webinars, Clients, Business Partners and IBMers are welcome to send an email request to [email protected]. Located in the Accelerate with IBM Storage Blog: https://www.ibm.com/developerworks/mydeveloperworks/blogs/accelerate/?lang=en Also, check out the WSC YouTube Channel here: https://www.youtube.com/playlist?list=PLSdmGMn4Aud-gKUBCR8K0kscCiF6E6ZYD&disable_polymer=true 2018 Webinars: January 9 – DS8880 Easy Tier January 17 – Start 2018 Fast! What's New for Spectrum Scale V5 and ESS February 8 - VersaStack - Solutions For Fast Deployments February 16 - TS7700 R4.1 Phase 2 GUI with Live Demo February 22 - DS8880 Transparent Cloud Tiering Live Demo March 1 - Spectrum Scale/ESS Application Case Study Register Here: https://ibm2.webex.com/ibm2/onstage/g.php?MTID=e25146b6c1207cb081f4392087fb6f73a March 7 - Spectrum Storage Management, Control, Insights, Foundation; what’s the difference? Register Here: https://ibm2.webex.com/ibm2/onstage/g.php?MTID=e3165dfc6c698c8fcb83132c95ae6dfe7 March 15 - IBM FlashSystem A9000/R and SVC Configuration Best Practices Register Here: https://ibm2.webex.com/ibm2/onstage/g.php?MTID=e87d423c5cccbdefbbb61850d54f70f4b © Copyright IBM Corporation 2018.
    [Show full text]
  • Robust Architectural Support for Transactional Memory in the Power Architecture
    Robust Architectural Support for Transactional Memory in the Power Architecture Harold W. Cain∗ Brad Frey Derek Williams IBM Research IBM STG IBM STG Yorktown Heights, NY, USA Austin, TX, USA Austin, TX, USA [email protected] [email protected] [email protected] Maged M. Michael Cathy May Hung Le IBM Research IBM Research (retired) IBM STG Yorktown Heights, NY, USA Yorktown Heights, NY, USA Austin, TX, USA [email protected] [email protected] [email protected] ABSTRACT in current p795 systems, with 8 TB of DRAM), as well as On the twentieth anniversary of the original publication [10], strengths in RAS that differentiate it in the market, adding following ten years of intense activity in the research lit- TM must not compromise any of these virtues. A robust erature, hardware support for transactional memory (TM) system is one that is sturdy in construction, a trait that has finally become a commercial reality, with HTM-enabled does not usually come to mind in respect to HTM systems. chips currently or soon-to-be available from many hardware We structured TM to work in harmony with features that vendors. In this paper we describe architectural support for support the architecture's scalability. Our goal has been to TM provide a comprehensive programming environment includ- TM added to a future version of the Power ISA . Two im- ing support for simple system calls and debug aids, while peratives drove the development: the desire to complement providing a robust (in the sense of "no surprises") execu- our weakly-consistent memory model with a more friendly tion environment with reasonably consistent performance interface to simplify the development and porting of multi- and without unexpected transaction failures.2 TM must be threaded applications, and the need for robustness beyond usable throughout the system stack: in hypervisors, oper- that of some early implementations.
    [Show full text]
  • Powerview Command Reference
    PowerView Command Reference TRACE32 Online Help TRACE32 Directory TRACE32 Index TRACE32 Documents ...................................................................................................................... PowerView User Interface ............................................................................................................ PowerView Command Reference .............................................................................................1 History ...................................................................................................................................... 12 ABORT ...................................................................................................................................... 13 ABORT Abort driver program 13 AREA ........................................................................................................................................ 14 AREA Message windows 14 AREA.CLEAR Clear area 15 AREA.CLOSE Close output file 15 AREA.Create Create or modify message area 16 AREA.Delete Delete message area 17 AREA.List Display a detailed list off all message areas 18 AREA.OPEN Open output file 20 AREA.PIPE Redirect area to stdout 21 AREA.RESet Reset areas 21 AREA.SAVE Save AREA window contents to file 21 AREA.Select Select area 22 AREA.STDERR Redirect area to stderr 23 AREA.STDOUT Redirect area to stdout 23 AREA.view Display message area in AREA window 24 AutoSTOre ..............................................................................................................................
    [Show full text]
  • Assessment Exam List & Pricing 2017~ 2018
    Withlacoochee Technical College Assessment Exam List & Pricing 2017~ 2018 WTC is an authorized Pearson VUE, Prometric, and Certiport Testing Center TABLE OF CONTENTS ASE/NATEF STUDENT CERTIFICATION 6 Automobile 6 Collision and Refinish 6 M/H Truck 6 CASAS 6 Life and Work Reading 6 Life and Work Listening 7 CJBAT 7 Corrections 7 Law Enforcement 7 COSMETOLOGY HIV COURSE EXAM 7 ENVIRONMENTAL PROTECTION AGENCY EXAMS 7 EPA 608 Technician Certification 7 EPA 608 Technician Certification 7 Refrigerant-410A 7 Indoor Air Quality 7 PM Tech Certification 7 Green Certification 8 FLORIDA DEPARMENT OF LAW ENFORCEMENT STATE OFFICER CERTIFICATION EXAM 8 GED READY™ 8 GED® TEST 8 MANUFACTURING SKILL STANDARDS COUNCIL 8 Certified Production Technician 8 Certified Logistics Technician 9 MICROSOFT OFFICE SPECIALIST 9 MILADY 9 NATE 9 NATE ICE EXAM 10 NATIONAL HEALTHCAREER ASSOCIATION 10 Clinical Medical Assistant (CCMA) 10 Phlebotomy Technician (CPT) 10 Pharmacy Technician (CPhT) 10 Medical Administrative Assistant (CMAA) 10 Billing & Coding Specialist (CBCS) 10 EKG Technician (CET) 10 Patient Care Technician/Assistant (CPCT/A) 10 Electronic Health Record Specialist (CEHRS) 10 NATIONAL LEAGUE FOR NURSING 10 NCCER 10 NOCTI 11 NRFSP ( NATIONAL REGISTRY OF FOOD PROFESSIONALS) 12 PROMETRIC CNA 12 SERVSAFE 12 TABE 12 PEARSON VUE INFORMATION TECHNOLOGY (IT) EXAMS 13 Adobe 13 Alfresco 14 Android ATC 14 AppSense 14 Aruba 14 Avaloq 14 Avaya, Inc. 15 BCS/ISEB 16 BICSI 16 Brocade 16 Business Objects 16 Page 3 of 103 C ++ Institute 16 Certified Healthcare Technology Specialist
    [Show full text]
  • Openpower AI CERN V1.Pdf
    Moore’s Law Processor Technology Firmware / OS Linux Accelerator sSoftware OpenStack Storage Network ... Price/Performance POWER8 2000 2020 DRAM Memory Chips Buffer Power8: Up to 12 Cores, up to 96 Threads L1, L2, L3 + L4 Caches Up to 1 TB per socket https://www.ibm.com/blogs/syst Up to 230 GB/s sustained memory ems/power-systems- openpower-enable- bandwidth acceleration/ System System Memory Memory 115 GB/s 115 GB/s POWER8 POWER8 CPU CPU NVLink NVLink 80 GB/s 80 GB/s P100 P100 P100 P100 GPU GPU GPU GPU GPU GPU GPU GPU Memory Memory Memory Memory GPU PCIe CPU 16 GB/s System bottleneck Graphics System Memory Memory IBM aDVantage: data communication and GPU performance POWER8 + 78 ms Tesla P100+NVLink x86 baseD 170 ms GPU system ImageNet / Alexnet: Minibatch size = 128 ADD: Coherent Accelerator Processor Interface (CAPI) FPGA CAPP PCIe POWER8 Processor ...FPGAs, networking, memory... Typical I/O MoDel Flow Copy or Pin MMIO Notify Poll / Int Copy or Unpin Ret. From DD DD Call Acceleration Source Data Accelerator Completion Result Data Completion Flow with a Coherent MoDel ShareD Mem. ShareD Memory Acceleration Notify Accelerator Completion Focus on Enterprise Scale-Up Focus on Scale-Out and Enterprise Future Technology and Performance DriVen Cost and Acceleration DriVen Partner Chip POWER6 Architecture POWER7 Architecture POWER8 Architecture POWER9 Architecture POWER10 POWER8/9 2007 2008 2010 2012 2014 2016 2017 TBD 2018 - 20 2020+ POWER6 POWER6+ POWER7 POWER7+ POWER8 POWER8 P9 SO P9 SU P9 SO 2 cores 2 cores 8 cores 8 cores 12 cores w/ NVLink
    [Show full text]
  • IBM Power System E850 the Most Agile 4-Socket System in the Marketplace, Optimized for Performance, Reliability and Expansion
    IBM Systems Data Sheet IBM Power System E850 The most agile 4-socket system in the marketplace, optimized for performance, reliability and expansion Businesses today are demanding faster insights that analyze more data in Highlights new ways. They need to implement applications in days versus months, and they need to achieve all these goals while reducing IT costs. This is ●● ●●Designed for data and analytics, delivers creating new demands on IT infrastructures, requiring new levels of per- secure, reliable performance in a compact, 4-socket system formance and the flexibility to respond to new business opportunities, all at an affordable price. ●● ●●Can flexibly scale to rapidly respond to changing business needs The IBM® Power® System E850 server offers a unique blend of ●● ●●Can reduce IT costs through application enterprise-class capabilities in a space-efficient, 4-socket system with consolidation, higher availability and excellent price performance. With up to 48 IBM POWER8™ processor virtualization to yield over 70 percent utilization cores, advanced IBM PowerVM® virtualization that can yield over 70 percent system utilization and Capacity on Demand (CoD), no other 4-socket system in the industry delivers this combination of performance, efficiency and business agility. These capabilities make the Power E850 server an ideal platform for medium-size businesses and as a departmental server or data center building block for large enterprises. Designed for the demands of big data and analytics Businesses are amassing a wealth of data and IBM Power Systems™, built with innovation to support today’s data demands, can store it, secure it and, most important, extract actionable insight from it.
    [Show full text]
  • IBM XIV Storage System Storage Reinvented: Secure, Cloud-Optimized Enterprise Storage That Scales with Ease
    IBM Systems and Technology Data Sheet IBM XIV Storage System Storage reinvented: Secure, cloud-optimized enterprise storage that scales with ease As the planet becomes more instrumented, interconnected and intelli- Highlights gent, your business faces the challenge of managing huge quantities of data and extracting the most value from it—efficiently and flexibly— ●● ●●Deliver consistent, tuning-free, high while meeting the needs of employees, partners and customers. Having performance and remarkable ease of use via a grid-based architecture the right storage is fundamental to survival and growth. ●● ●●Provide linear scaling up to 325 TB per IBM® XIV® Storage System is high-end disk storage that supports the array and IBM Hyper-Scale for extreme operational agility over multiple systems need for high performance, availability, operational flexibility and security while helping minimize costs and complexity. Built optimized to simplify ●● ●●Enable elasticity, open-standards storage, XIV Storage System is enabling thousands of organizations to support and mixed-workload affinity for optimized compute clouds and take control of their storage and gain business insights from their data. virtualized environments Designed for consistent, enterprise-level performance and five-nines availability, XIV storage handles static and dynamic workloads with ease. ●● ●●Offer high reliability and availability via full redundancy, self healing and Never compromising performance for reliability, the XIV grid architec- unprecedented rebuild speed ture delivers massive parallelism—resulting in uniform allocation of ●● ●●Provide compelling data economics system resources at all times. XIV storage secures your data through through superb price-performance, industry-standard data-at-rest encryption while keeping performance low-touch and simplified management, uninterrupted—with separate key management support by IBM Tivoli® footprint density, power efficiency and all-inclusive software licensing Key Lifecycle Manager.
    [Show full text]
  • IBM Energyscale for POWER8 Processor-Based Systems
    IBM EnergyScale for POWER8 Processor-Based Systems November 2015 Martha Broyles Christopher J. Cain Todd Rosedahl Guillermo J. Silva Table of Contents Executive Overview...................................................................................................................................4 EnergyScale Features.................................................................................................................................5 Power Trending................................................................................................................................................................5 Thermal Reporting...........................................................................................................................................................5 Fixed Maximum Frequency Mode...................................................................................................................................6 Static Power Saver Mode.................................................................................................................................................6 Fixed Frequency Override...............................................................................................................................................6 Dynamic Power Saver Mode...........................................................................................................................................7 Power Management's Effect on System Performance................................................................................................7
    [Show full text]