<<

Solenoid operated poppet valve detented NG6 construction ISO 4401-03 ◆◆3/2-way ◆◆ ​ Qmax = 40 l/min ◆◆ pmax = 350 bar

DESCRIPTION ​ APPLICATION ​ Direct operated 3/2-way poppet valve in flange construc- Poppet valves are used where tight closing functions of the valve tion. By means of the tight switching solenoid, the poppet are essential like leakage-free load holding, clamping or gripping. ​ ​ ​ valve spool is opened or closed acting against the spring and is held in the switching position by the form-closed detent. Due to the poppet spool construction with pressure compensation on both sides, the flow through the valve is possible in both directions. The metallically sealing seat closes the valve virtually free. ​ ​ ​ ​

SYMBOL ​ Simplified Detailed A

a b a b P T ​ A

a 0 b a b P T ​

TYPE CODE ​ A 3 2 06 rr - - # International standard interface ISO

Solenoid, Medium M Solenoid, Super S

3 way (connections)

2 switching positions

Nominal size 6

Detent on both sides

Nominal voltage UN 12 VDC G12 115 VAC R115 24 VDC G24 230 VAC R230

Sealing material / NBR range FKM (Viton) D1 NBR -40 °C Z604

Design index (subject to change) 1.11-2146

www.wandfluh.com Illustrations are not binding Data subject to change 1/3 Edition: 18 43 1.11-2146 E Poppet valve

GENERAL SPECIFICATIONS ​ HYDRAULIC SPECIFICATIONS ​

Designation 3/2-way poppet valve Working pressure Medium: pmax = 160 bar

Construction Direct operated Super: pmax = 350 bar

Mounting Flange construction Maximum volume flow Q max = 40 l/min, see characteristic Nominal size NG6 according to ISO 4401-03 Volume flow direction Any (see characteristic) Actuation Switching solenoid Leakage oil Seat tight, max. 0,05 ml / min (approx. 1 Ambient temperature -25…+70 °C (NBR) drop / min) at 30 cSt -20…+70 °C (FKM) Fluid Mineral oil, other fluid on request Weight 3,5 kg Viscosity range 12 mm2/s…320 mm2/s MTTFd 150 years Temperature range -25…+70 °C fluid Contamination Class 20 / 18 / 14 efficiency Filtration Required filtration grade ß 10…16 ≥ 75, see data sheet 1.0-50

ELECTRICAL SPECIFICATIONS ​ ACTUATION ​ Protection class IP65 Actuation Switching solenoid, wet pin push type, Relative duty factor 100 % DF pressure tight Switching frequency 7'500 / h Execution Medium: SIN45V (Data sheet 1.1-120) Service life time 107 (number of switching cycles, Super: SIS45V (Data sheet 1.1-125) theoretically) Connection Connector socket EN 175301 – 803 Voltage tolerance ± 10 % with regard to nominal voltage Standard nominal 12 VDC, 24VDC, 115 VAC, 230 VAC voltage AC = 50 to 60 Hz, rectifier integrated in the connector socket

Note! Other electrical specifications see data sheet 1.1-120 (Medium) and 1.1-125 (Super)

PERFORMANCE SPECIFICATIONS ​ Oil viscosity u = 30 mm2/s p = f (Q) Performance limits Δp = f (Q) Pressure drop volume flow characteristics Measured with nominal voltage -10 % p [bar] 35 K0078 30 p [bar] K4202 25 350 Super 20 300 15 250 Medium 10 200 5 150 0 100 0 5 10 15 20 25 30 35 40 Q [l/min] 50 0 ​ 0 5 10 15 20 25 30 35 40 Q [l/min] ​ Attention! Long periods of non-actuation can reduce the switching performance

VALVES INSTALLED ​ The central functioning element is the poppet valve cartridge NG6, data sheet 1.11-2030.

www.wandfluh.com Illustrations are not binding Data subject to change 2/3 Edition: 18 43 1.11-2146 E Poppet valve

DIMENSIONS ​ HYDRAULIC CONNECTION ​ ​ ​ 35 17.8 30 9.5 A 5.5 B MD= 5.2Nm T

7.9 A B 85.2 31 21

E 32.5 45 45.9

15 38 P

50 10 70 21.5 MD= 5.2Nm 40.5 4 64.2 25 72.3 ​ 270.2 E = Air bleed screw ​

PARTS LIST ​ ACCESSORIES ​ Position Article Description Fixing screws Data sheet 1.0-60 10 260.6... Solenoid SIN45V Threaded subplates Data sheet 2.9-30 260.7... Solenoid SIS45V Multi-station subplates Data sheet 2.9-60 15 239.2033 Screw plug HB0 (incl. seal) Module type manifold blocks Data sheet 2.9-100 30 219.2001 Electric plug A (grey) Technical explanations Data sheet 1.0-100 35 219.2002 Electric plug B (black) Hydraulic fluids Data sheet 1.0-50 50 246.2190 Socket head screw M5 x 90 DIN 912 Filtration Data sheet 1.0-50 70 160.2093 O-ring ID 9,25 x 1,78 (NBR) Relative duty factor Data sheet 1.1-430 160.6092 O-ring ID 9,25 x 1,78 (FKM)

MANUAL OVERRIDE ​ SEALING MATERIAL ​ Screw plug (HB0), no actuation possible NBR or FKM (Viton) as standard, choice in the type code Optionally: HB6 or HN(K) → See data sheet 1.1-311

STANDARDS ​ SURFACE TREATMENT ​ Mounting interface ISO 4401-03 ◆◆The valve body is painted with a two component paint ◆◆The solenoid and the flange are zinc- coated DIN VDE 0580 ◆◆The socket head screws are zinc coated Connection execution D EN 175301 – 803 Protection class EN 60 529 Contamination efficiency ISO 4406

COMMISSIONING ​ INSTALLATION NOTES ​ Attention! When commissioning, the valve must be vented under Mounting type Flange mounting pressure (max. two rotations of screw E). 4 fixing holes for socket head screws M5 x 45 Mounting position Any, preferably horizontal

Tightening Fixing screws MD = 5,2 Nm (screw quality 8.8, zinc coated)

Note! The length of the fixing screw depends on the base material of the connection element.

Wandfluh AG Postfach CH-3714 Frutigen Tel. +41 33 672 72 72 Fax +41 33 672 72 12 [email protected]

www.wandfluh.com Illustrations are not binding Data subject to change 3/3 Edition: 18 43 1.11-2146 E