aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding

Denison GOLD CUP® Product Catalog Piston Pumps & Motors For Open & Closed Circuits HY28-2667-01/GC/NA,EU Effective: June 01, 2013 Hydraulic Pump Division and Denison Hydraulics

The Hydraulic Pump Division of Parker Hannifin was formed in 2004 when our significant piston pump business was expanded through the acquisition of Denison Hydraulics. The addition of Denison allowed us to marry the wealth of knowledge that both companies have in the design, manufacture, and application of piston products in both open circuit and closed circuit system applications. Since before WWII, Denison products have been chosen for Military test stand applications and for shipboard hydraulic applications being recognized as technology leaders.

The heavy duty GOLD CUP® series of pumps and motors in this catalog represent a broadening of our product offering with hydrostatic transmission applications in marine, drilling, and shredding applications, among others. The tried and true design of the GOLD CUP® product line incorporates features such as integral servo and replenishing pump, hot oil shuttle, and a unique servo control system; all of which combine to provide a rugged self contained package which can withstand the harshest of conditions and continue to perform with trouble free long life.

The division is a leading worldwide manufacturer of hydraulic components and systems for earthmoving and construction vehicles; for mining equipment; for pulp and paper, chemical and other processing equipment; for ships and ordnance equipment; and for such in-plant machines as machine tools, plastic molding, die casters, and stamping presses.

The product information, specifications, and descriptions contained in this publication have been compiled for the use and convenience of our customers from information furnished by the manufacturer; and we can not, and do not, accept any responsibility for the accuracy or correctness of any description, calculation, specifica- tion, or information contained herein. No such description, calculation, specification, or information regarding the products being sold has been made part of the basis of the bargain, nor has same created or amounted to an express warranty that the products would conform thereto. We are selling the goods and merchandise illustrated and described on this publication on an “as is” basis, and disclaim any implied warranty, including any warranty of merchantability or warranty of fitness for any particular purpose whatsoever, with respect to the goods and mer- chandise sold. All manufacturer warranties shall be passed on to our customers, but we shall not be responsible for special, indirect, incidental, or consequential damages resulting from the use of any of the products or informa- tion contained or described on this publication. Further, we reserve the right to revise or otherwise make product improvements at any time without notification.

WARNING - USER RESPONSIBILITY FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE. This document and other information from Parker-Hannifin Corporation, its subsidiaries and authorized distributors provide product or system options for further investigation by users having technical expertise.

The user, through its own analysis and testing, is solely responsible for making the final selection of the system and components and assuring that all performance, endurance, maintenance, safety and warning requirements of the application are met. The user must analyze all aspects of the application, follow applicable industry standards, and follow the information concerning the product in the current product catalog and in any other materials provided from Parker or its subsidiaries or authorized distributors. To the extent that Parker or its subsidiaries or authorized distributors provide component or system options based upon data or specifications provided by the user, the user is responsible for determining that such data and specifications are suitable and sufficient for all applications and reasonably foreseeable uses of the components or systems.

OFFER OF SALE The items described in this document are hereby offered for sale by Parker-Hannifin Corporation, its subsidiaries or its authorized distributor. This offer and its acceptance are governed by the provisions stated in the detailed "Offer of Sale" elsewhere in this document.

© Copyright 2013, Parker Hannifin Corporation. All Rights Reserved. Mining Photo on Front Cover is the Property of Atlas Copco.

2 87 HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps Contents GOLD CUP® Series - Open & Closed Circuits Contents Contents ...... 3 Technical Data ...... 4 Features ...... 7 Description ...... 8 Pump, Motor Dimensions P6, 7, 8 ...... 10 M6, 7, 8 ...... 14 P11, 14 ...... 17 M11, 14 ...... 21 P24, 30 ...... 24 M24, 30 ...... 29 Controls Dimensions 10, 2A ...... 34, 41 2H, 4A ...... 35 5A, 5C ...... 36, 41 7D, 7J ...... 37 7F, 7K ...... 38 8A, 8C ...... 39, 42 9A, 9C ...... 40, 42 **4 ...... 43 **6, **8, **2 ...... 44 Rear Adapters table ...... 45 P6,7,8 ...... 46-47 P11,14 ...... 46, 48-50 P24,30 ...... 51-54 Inlet Conditions ...... 55 Performance Curves ...... 56-61 Pump Primary Displacement Control Options...... 62-70 Secondary Control Options ...... 70-71 Hydraulic Schematics ...... 72-76 GOLD CUP® Pump Control Combinations...... 77 Pump Ordering Code ...... 78-79 GOLD CUP® Motor Control Combinations ...... 81 Motor Ordering Code ...... 82-83 Offer of Sale ...... 87

Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA 3 HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps Technical Data GOLD CUP® Series - Open & Closed Circuits

seireS 6PsmreT 03P42P41P11P8P7P Displacement Max. displacement in3/rev. 6.00 7.25 8.00 11.00 14.00 24.60 30.60 cm3/rev. 98,3 118,8 131,1 180,3 229,5 403,2 501,5 Pressure Continuous psi 5000 5000 5000 5000 5000 50001) 50001) bar 350 350 250 350 350 3501) 3501) Intermittent psi 60007) 60007) 5000 60007) 60007) 55001)7) 55001)7) bar 4207) 4207) 3107) 4207) 4207) 3701)7) 3701)7) Speed (Pump) max. @ full stroke rpm 3000 3000 2100 2400 2400 21002) 1800 (Motor ) max. @ full stroke rpm 3000 3000 NA 2400 2400 21002) 1800 (Motor ) max. @ 50% stroke rpm 3600 3600 NA 2800 2800 21002) 1800 Mounting Flange -2 bolt SAE 127-2 (C) 127-2 (C) 127-2 (C) - - - - Flange -4 bolt (opt. on 6,7 & 8) SAE 152-4 (D) 152-4 (D) 152-4 (D) 165-4 (E) 165-4 (E) 177-4 (F) 177-4 (F) Shaft - keyed SAE 32-1 (C) 32-1 (C) 32-1 (C) 44-1 (E) 44-1 (E) 50-1 (F) 50-1 (F) keyed SAE 44-1 (D) 44-1 (D) 44-1 (D) - - - - Shaft - splined SAE 32-4 (C) 32-4 (C) 32-4 (C) 44-4 (E) 44-4 (E) 50-4(F) 50-4 (F) splined SAE 44-4 (D) 44-4 (D) 44-4 (D) - - - - Weight (Pump) less controls lbs 175-300 175-300 175-300 325-530 325-530 750-835 750-835 Mass kg. 80-135 80-135 80-135 145-240 145-240 340-375 340-375 Weight (Motor Fixed) lbs 110 110 N/A 250 250 510 600 Mass kg. 50 50 N/A 110 110 230 270 Weight ( Motor Variable) less controls lbs 110 110 N/A 300 300 650 670 Mass kg. 50 50 N/A 135 135 290 300 Rotating inertia lbs-in2 92 92 92 290 290 821 977 kg.m2 0,027 0,027 0,027 0,085 0,085 0,240 0,286 Torque (Motor) theo. max. per 100 psi lbs-in 95.5 115.4 NA 175 222 392 487 per 100 bar Nm 157 189 NA 287 362 623 797 at 5000 psi lbs-in 4774 5769 NA 8750 11100 19576 24351 at 350 bar Nm 539,5 651,9 NA 990 1250 2158 2752 Power (Motor) theo. max.at 5000 psi, 350 bar per 100 rpm hp 7.6 9.2 NA 13.8 17.6 31.1 38.6 kW 5,7 6,8 NA 10,3 13,1 23,1 28,8 at 2000 rpm hp 151.5 183.1 NA 277.8 353.5 621.3 695 kW 113,0 136,6 NA 207,0 263,7 463,5 518,2 Torque (Motor) efficiency - approx. stalled % theo. 81 81 NA 81 81 81 81 running % theo. 93 93 NA 93 93 93 93 Case pressure: max. allowable continuous psi 75 75 75 75 75 75 bar 5,2 5,2 5,2 5,2 5,2 5,2 5,2 5,2 intermittent psi 125 125 125 125 125 125 125 bar 8,6 8,6 8,6 8,6 8,6 8,6 8,6 (Not to exceed 25 psi,1,7 bar above inlet in open circuit units) Flow (Pump) theo.at max.displ.@1500 rpm gpm 39 47 52 71 91 160 199 lpm 148 178 197 269 344 606 753 @1800 rpm gpm 47 57 62 86 109 192 238 lpm 178 216 235 326 413 727 901 Displacement (Internal aux. pump) P6,7,8P,S,V P11,14P,S P11,14V P24P P24S3) P30P P30S3) in3/rev. 1.07 (2) 1.074) 1.075) 2.816) 2.816) 2.816) 2.816) cm3/rev. 17,5 (2) 17,5 17,5 46,1 46,1 46,1 46,1 Flow (Internal aux. pump) @1500 rpm gpm 6.9 (2) 6.9 6.9 18.2 6.5 18.2 6.5 lpm 26,1 (2) 26,1 26,1 68,9 24,6 69,1 24,6 @1800 rpm gpm 8.3 (2) 8.3 8.3 21.9 7.8 21.9 7.8 lpm 31,4 (2) 31,4 31,4 82,9 29,5 82,9 29,5

1) Max. pressure 5000 psi, (350 bar) for M24 and 30 series variable motors. Higher servo pressure may be required - consult Parker.

2) On HF-1 fluids, 1800 RPM Max. on HF-0 fluids.

3) Internal cartridge provides servo flow and must be supercharged from external replenishing flow, from external auxiliary pump.

4) One servo cartridge and one replenishing cartridge.

5) Servo cartridge only.

6) Standard, other sizes available, see ordering code.

7) 10% of operation time, not exceeding 6 successive seconds.

Parker Hannifin Corporation Hydraulic Pump Division 4 Marysville, Ohio USA HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps Technical Data GOLD CUP® Series - Open & Closed Circuits

Replenishing pressure (Internal aux. pump) P6,7,8,11,14,24P P6,7,8,11,14,24S P30P P30S Replenish pressure minus case pressure psi 180-220* 180-220 180-220* 180-220 bar 12,4-15,2 12,4-15,2 12,4-15,2 12,4-15,2 Servo pressure (Internal aux. pump) psi 308-420 308-420 308-420 308-420 Servo pressure minus case pressure bar 21,2-29,0 21,2-29,0 21,2-29,0 21,2-29,0 at 0 psi, 0 bar discharge pressure (Above Servo pressure (Internal aux. pump) repl.) psi 500-650 500-650 500-650 500-650 for HI-IQ control units. Servo pressure minus bar 34,5-44,8 34,5-44,8 34,5-44,8 34,5-44,8 case pressure at 5000 psi, 350 bar discharge pressure - at system pressure range 0 to 5000 psi, 350 bar.

*Note: Nominal setting, may be increased if required.

seireS 03P42P41P11P8P7P6PsmreT Controls Compensator response off-stroke sec. 0.05 0.05 0.05 0.07 0.07 0.10 0.10 (per SAE J497 @ 5000 psi, 350 bar) on-stroke sec. 0.9 0.9 0.9 1.5 1.5 1.8 1.8 Compensator adjustment psi/turn 2000 2000 2000 2000 2000 2000 2000 bar/turn 138 138 138 138 138 138 138 Torque to turn rotary servo shaft in.-lbs 20 20 20 20 20 20 20 Nm 2,3 2,3 2,3 2,3 2,3 2,3 2,3

The maximum inlet at the auxiliary pump inlet is 200 psi. (13,8 bar)

Minimum compensating pressure will always be 100-200 psi. (6,9-13,8 bar) over servo pressure.

Any inlet pressures above atmospheric will increase noise levels and decrease efficiencies noted in this literature. Exact measurements depend on each application and operating conditions. Please consult your nearest Parker Office for further details.

*Standard factory compensating pressure is 1,000 psi. (69,0 bar).

Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA 5 HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps Technical Data GOLD CUP® Series - Open & Closed Circuits

REAR DRIVE TORQUE CAPACITY

REAR DRIVE TORQUE CAPACITY TNORF TUPNI TFAHS RAER SGNITNUOM RAER TUPTUO TFAHS SAE SERIES TNORF TYPETUPNI TFAHS TORQUE CAPACITY ARAER BSGNITNUOM C DRAER E TUPTUO FTFAHS TORQUE CAPACITY SAE SERIES P6,7,8TYPE Keyed SAETORQUE 32-1(C) CAPACITY 6920 A in-lbs. B•• C D E F TORQUE CAPACITY 1750 in-lbs. P,S,V,X,D Spline SAE 32-4(C) (780 Nm) •• (195 Nm) P6,7,8 Keyed SAE 32-1(C) 6920 in-lbs. •• 1750 in-lbs. P,S,V,X,D P6,7,8 Spline SAE 32-4(C) Keyed SAE 44-1(D)(780 Nm) 6920•• in-lbs. •• (195 Nm) 1750 in-lbs. P6,7,8P,S,V,X,D Keyed SAE 44-1(D) Spline SAE 44-4(D) 6920 in-lbs. (780•• Nm) •• 1750 in-lbs. (195 Nm) P,S,V,X,D P6,7,8 Spline SAE 44-4(D) Keyed SAE 32-1(C)*(780 Nm) 13,845•• in-lbs. ••• (195 Nm) 6920 in-lbs. P6,7,8R,L Keyed only SAE 32-1(C)* Spline SAE 32-4C 13,845 in-lbs. (1565••• Nm) ••• 6920 in-lbs. (780 Nm) R,L only Spline SAE 32-4C (1565 Nm) ••• (780 Nm) P11,14 Keyed SAE 44-1(E) 13,370 in-lbs. ••• 2400 in-lbs. P11,14P,S,V,X Keyed SAE 44-1(E) Spline SAE 44-4(E) 13,370 in-lbs. (1510••• Nm) ••• 2400 in-lbs. (270 Nm) P,S,V,X Spline SAE 44-4(E) (1510 Nm) ••• (270 Nm) P11,14 Keyed SAE 44-1(E)* 26735 in-lbs. 13,370 in-lbs. P11,14 Keyed SAE 44-1(E)* 26735 in-lbs. •••••13,370 in-lbs. R,L only Spline SAE 44-4(E) (3020••••• Nm) (1510 Nm) R,L only Spline SAE 44-4(E) (3020 Nm) ••••••••••(1510 Nm) P24,30P24,30 Keyed SAE 50-1(F) Keyed SAE 50-1(F) 24350 in-lbs. 24350 in-lbs. •• •• 2700 in-lbs. 2700 in-lbs. P,S,X P,S,X Spline SAE 50-4(F) Spline SAE 50-4(F)(2750 Nm) (2750 Nm) •• •• (305 Nm) (305 Nm) P24,30P24,30 Keyed SAE 50-1(F) Keyed SAE 50-1(F) 48,700* in-lbs. 48,700* in-lbs. ••••••••••24,350 in-lbs 24,350 in-lbs R,L onlyR,L Spline only SAE 50-4(F) Spline SAE 50-4(F) (5,500 Nm) (5,500 Nm) ••••••••••(2750 Nm) (2750 Nm) * Coupling for* keyedCoupling shaft for must keyed be pressed shaft must fit for be full pressed torque capability fit for full. torque capability.

P6/7/8 SAE 127-2P6/7/8 Mtg., SAE 32-1, 127-2 4 Shaft Mtg., Bearing 32-1, 230-82140 4 Shaft Bearing (6007) 230-82140 (6007) Speed (rpm) 1000 1000 1000 1000 1200 1200 1200 1200 1500 1500 1500 1500 1800 1800 1800 1800 Speed (rpm) 1000 1000 1000 1000 1200 1200 1200 1200 1500 1500 1500 1500 1800 1800 1800 1800 )sbl( daoL tfahS daoL )sbl( * 0 0 00010001 0 0 00010001 0 0 00010001 0 0 00010001 )sbl( daoL tfahS daoL )sbl( * 0 0 00010001 0 0 00010001 0 0 00010001 0 0 00010001 )N( daoL tfahS daoL )N( * 0 0 84448444 0 0 84448444 0 0 84448444 0 0 84448444 Case Pressure (psi)tfahS daoL 0)N( * 25 00 25 0 0 25 084448444 250 0 0 25 084448444 250 00 25 0 2584448444 0 0 84448444 Case Pressure (bar)Case Pressure 0.0 (psi) 1.7 0.0 0 1.7 25 0.0 0 1.7 25 0.0 1.7 0 0.0 25 1.7 0 0.0 25 1.7 0 0.0 25 1.7 0 0.0 25 1.7 0 25 0 25 B-10 Life (hours xCase 1000) Pressure 8E+08 (bar) 1833 0.778 0.0 0.778 1.7 6E+08 0.0 1528 1.7 0.648 0.648 0.0 5E+08 1.7 1222 0.0 0.518 1.7 0.518 0.0 4E+08 1.7 1018 0.0 0.432 1.7 0.432 0.0 1.7 0.0 1.7 B-10 Life (hours x 1000) 8E+08 1833 0.778 0.778 6E+08 1528 0.648 0.648 5E+08 1222 0.518 0.518 4E+08 1018 0.432 0.432 P6/7/8 SAE 152-4 Mtg., 44-1, 4 Shaft Bearing 230-00207-0 (6207) Speed (rpm) P6/7/8 SAE1000 152-4 1000 Mtg., 1000 44-1, 1000 4 1200Shaft Bearing 1200 1200 230-00207-0 1200 1500 (6207) 1500 1500 1500 1800 1800 1800 1800 )sbl( daoL tfahS daoL )sbl( *Speed (rpm)0 0 100000010001 10000 1000 0 1000 120000010001 12000 1200 0 1200 150000010001 0 1500 0 1500 150000010001 1800 1800 1800 1800 )N( daoL tfahS daoL )N( * 0 0 84448444 0 0 84448444 0 0 84448444 0 0 84448444 )sbl( daoL tfahS daoL )sbl( * 0 0 00010001 0 0 00010001 0 0 00010001 0 0 00010001 Case Pressure (psi) 0 25 0 25 0 25 0 25 0 25 0 25 0 25 0 25 )N( daoL tfahS daoL )N( * 0 0 84448444 0 0 84448444 0 0 84448444 0 0 84448444 Case Pressure (bar) 0.0 1.7 0.0 1.7 0.0 1.7 0.0 1.7 0.0 1.7 0.0 1.7 0.0 1.7 0.0 1.7 Case Pressure (psi) 0 25 0 25 0 25 0 25 0 25 0 25 0 25 0 25 B-10 Life (hours x 1000) 3E+09 7394 3.136 3.136 3E+09 6161 2.613 2.613 2E+09 4929 2.09 2.09 2E+09 4170 1.742 1.742 Case Pressure (bar) 0.0 1.7 0.0 1.7 0.0 1.7 0.0 1.7 0.0 1.7 0.0 1.7 0.0 1.7 0.0 1.7 P11/14 SAE 165-4B-10 LifeMtg., (hours 44-1, x 41000) Radial 3E+09Shaft Bearing 7394 230-82148-0 3.136 3.136 (6010) 3E+09 (2 & 6161 3 Shaft 2.613 Codes) 2.613 2E+09 4929 2.09 2.09 2E+09 4170 1.742 1.742 Speed (rpm) 1000 1000 1000 1000 1200 1200 1200 1200 1500 1500 1500 1500 1800 1800 1800 1800 Shaft Load (lbs) *P11/14 SAE0 165-4 0 Mtg., 1000 44-1, 1000 4 Radial 0 Shaft 0 1000Bearing 1000 230-82148-0 0 0 (6010) 1000 (2 1000 & 3 Shaft 0 Codes) 0 1000 1000 Shaft Load (N) * Speed (rpm)0 0 444810004448 1000 0 1000 0 10004448 1200 4448 1200 0 1200 0 4448 1200 4448 1500 0 1500 0 1500 4448 1500 4448 1800 1800 1800 1800 Case Pressure (psi)Shaft Load (lbs) 0* 25 00 25 0 0 1000 25 1000 0 250 0 0 100025 10000 25 0 0 0 25 1000 0 1000 25 0 0 1000 1000 Case Pressure (bar) 0.0 1.7 0.0 1.7 0.0 1.7 0.0 1.7 0.0 1.7 0.0 1.7 0.0 1.7 0.0 1.7 Shaft Load (N) * 0 0 4448 4448 0 0 4448 4448 0 0 4448 4448 0 0 4448 4448 B-10 Life (hours x 1000) 2E+09 535 1.907 1.907 2E+09 446 1.589 1.589 1E+09 356 1.272 1.272 1E+09 297 1.06 1.06 Case Pressure (psi) 0 25 0 25 0 25 0 25 0 25 0 25 0 25 0 25 P11/14 SAE 165-4Case PressureMtg., 44-1, (bar) 4 Spherical 0.0 Roller 1.7 Shaft Bearing 0.0 1.7230-82214-0 0.0 (22208) 1.7 (7 0.0 & 8 Shaft 1.7 Codes) 0.0 1.7 0.0 1.7 0.0 1.7 0.0 1.7 Speed (rpm) B-10 Life (hours1000 x 1000 1000) 1000 2E+09 1000 535 1200 1.907 1200 1.907 1200 2E+09 1200 1500 446 1500 1.589 1500 1.589 1500 1E+09 1800 356 1800 1.272 1800 1.272 1800 1E+09 297 1.06 1.06 Shaft Load (lbs) * 0 0 1000 1000 0 0 1000 1000 0 0 1000 1000 0 0 1000 1000 Shaft Load (N) * P11/14 SAE0 165-4 0 Mtg., 4448 44-1, 4448 4 Spherical 0 0 Roller 4448 Shaft 4448 Bearing 0 230-82214-0 0 4448 4448 (22208) 0 (7 & 0 8 Shaft 4448 Codes) 4448 Case Pressure (psi)Speed (rpm) 0 25 01000 25 1000 0 1000 25 1000 0 1200 25 1200 0 1200 25 12000 25 1500 0 1500 25 1500 0 1500 25 1800 1800 1800 1800 Case Pressure (bar)Shaft Load 0.0(lbs) * 1.7 0.00 1.7 0 0.0 1000 1.7 1000 0.0 1.7 0 0.0 0 1.71000 0.0 1000 1.7 0 0.0 0 1.7 1000 0.0 1000 1.7 0 0 1000 1000 B-10 Life (hours xShaft 1000) Load 16856 (N) * 2452 2750 172 0 14046 4448 2043 4448 230 143 0 11237 0 1635 4448 184 4448 114.8 0 9364 0 1363 4448 153 4448 95.7 0 0 4448 4448 Case Pressure (psi) 0 25 0 25 0 25 0 25 0 25 0 25 0 25 0 25 P24 SAE 177-4 Mtg., 50-1, 4 Shaft Bearing 230-82213-0 (22311) Case Pressure (bar) 0.0 1.7 0.0 1.7 0.0 1.7 0.0 1.7 0.0 1.7 0.0 1.7 0.0 1.7 0.0 1.7 Speed (rpm) 1000 1000 1000 1000 1200 1200 1200 1200 1500 1500 1500 1500 1800 1800 1800 1800 Shaft Load (lbs) *B-10 Life (hours0 x 1000) 0 1000 16856 1000 2452 0 275 0 172 1000 14046 1000 2043 0 2300 1000 143 1000 11237 0 1635 0 184 1000 114.8 1000 9364 1363 153 95.7 Shaft Load (N) * 0 0 4448 4448 0 0 4448 4448 0 0 4448 4448 0 0 4448 4448 Case Pressure (psi)P24 SAE 177-4 0 Mtg., 25 50-1, 0 4 25 Shaft 0Bearing 25 230-82213-0 0 25 (22311) 0 25 0 25 0 25 0 25 Case Pressure (bar)Speed (rpm) 0.0 1.7 0.01000 1.7 1000 0.0 1000 1.7 1000 0.0 1200 1.7 1200 0.0 1.71200 0.0 1200 1.7 1500 0.0 1500 1.7 1500 0.0 1500 1.7 1800 1800 1800 1800 B-10 Life (hours xShaft 1000) Load 591.6 (lbs) * 428.5 276.70 213.5 0 493 1000 357 1000 230.5 178 0 394.4 0 991.6 1000 184.4 1000 142.3 0 328.7 0 238 1000 153.7 1000 118.6 0 0 1000 1000 Shaft Load (N) * 0 0 4448 4448 0 0 4448 4448 0 0 4448 4448 0 0 4448 4448 P30 SAE 177-4Case Mtg., Pressure 50-1, 4(psi) Shaft Bearing 0 230-82213-0 25 (22311) 0 25 0 25 0 25 0 25 0 25 0 25 0 25 Speed (rpm) Case Pressure1000 (bar) 1000 1000 0.0 1000 1.7 1200 0.0 1200 1.7 1200 12000.0 1500 1.7 1500 0.0 1500 1.7 1500 0.0 1800 1.7 1800 0.0 1800 1.7 1800 0.0 1.7 0.0 1.7 Shaft Load (lbs) * 0 0 1000 1000 0 0 1000 1000 0 0 1000 1000 0 0 1000 1000 B-10 Life (hours x 1000) 591.6 428.5 276.7 213.5 493 357 230.5 178 394.4 991.6 184.4 142.3 328.7 238 153.7 118.6 Shaft Load (N) * 0 0 4448 4448 0 0 4448 4448 0 0 4448 4448 0 0 4448 4448 Case Pressure (psi) 0 25 0 25 0 25 0 25 0 25 0 25 0 25 0 25 Case Pressure (bar)P30 SAE 177-4 0.0 1.7Mtg., 50-1, 0.0 4 1.7 Shaft 0.0 Bearing 1.7 230-82213-0 0.0 1.7 (22311) 0.0 1.7 0.0 1.7 0.0 1.7 0.0 1.7 B-10 Life (hours xSpeed 1000) (rpm) 227 177.7 126.41000 102.8 1000 189.2 1000 148 1000 105.3 1200 85.6 151.3 1200 118.4 1200 84.2 1200 68.5 1500 126.1 1500 98.7 1500 70.2 1500 57.1 1800 1800 1800 1800 Shaft Load (lbs) * 0 0 1000 1000 0 0 1000 1000 0 0 1000 1000 0 0 1000 1000 *radial load at center of key or spline Shaft Load (N) * 0 0 4448 4448 0 0 4448 4448 0 0 4448 4448 0 0 4448 4448 Note: VariationCase in life Pressure is due to(psi) variations in 0tolerances 25 within 0 the pump. 25 0 25 0 25 0 25 0 25 0 25 0 25 Contact CaseParker Pressure Hydraulics (bar) for B-10 with 0.0 other 1.7 operating 0.0 conditions 1.7 0.0and with 1.7 other case 0.0 pressure 1.7 values. 0.0 1.7 0.0 1.7 0.0 1.7 0.0 1.7 Consult Parker Hydraulics for shaft side loads of P*R units. B-10 Life (hours x 1000) 227 177.7 126.4 102.8 189.2 148 105.3 85.6 151.3 118.4 84.2 68.5 126.1 98.7 70.2 57.1 *radial load at center of key or spline

Note: Variation in life is due to variations in tolerances within the pump. Parker Hannifin Corporation Contact Parker Hydraulics for B-10 with other operating conditions and with other case pressure values. Hydraulic Pump Division Consult Parker Hydraulics for shaft side loads of P*R units. 6 Marysville, Ohio USA 7 HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps Features GOLD CUP® Series - Open & Closed Circuits

1 Quick change valve block - easy to 10 Auxiliary pump can be changed without Standard compensator vent ports allow service or replace disassembling the transmission 15 for a wide variety of controls (See Applications Manual) 2 Quick change controls - easy to 11 Standard SAE keyed or splined drive service and change shafts are available Rocker cam displacement indicator helps 16 troubleshoot the system 3 Dampened low inertia rocker cam - High pressure mechanical shaft seals more stable, quieter and faster than 12 can be changed without disassembling 17 Modulated servo pressure saves power other designs the transmission. Double lip seals are also available 18 Standard Code 62 SAE split flange 4 Exclusive zero-backlash rotary servo connections design - lifetime accuracy 13 One piece stroking vane/cam means no lost motion, zero backlash, better control, 19 Conforms to SAE mounting standards. 5 Field adjustable compensator override - and no linkages to wear out easily adjusted without removing from 20 Fast compensator response. See page 5. machinery 14 Stroking vane seals are pressure loaded for longer life 21 Variable motors available for multiple 6 Precision barrel bearing, a distinctive speed ranges or constant power Denison Hydraulics feature for over 30 years - permits high speeds, high Note: 1. These products, with exception of 8 cubic inch units, are qualified to pressure and provides long life meet Military specifications MIL-P-17869A and MIL-S-901-C Grade A.

2. All GOLD CUP® Pumps and Motors* have ATEX approval. 7 Versatile controls - can be located on either side of pump or motor for *See ordering code for availability. maximum freedom of design 3. Consult factory for other approvals such as ABS and Lloyd's Registry.

8 Ring style replenishing checks fastest operation withor partsno sliding and low poppets pressure drop or parts and low pressure drop 19 9 Hot oil shuttle available - fast, reliable operation 19 9 Hot oil shuttle available - fast, reliable 21 6 operation 611 1821 12

20 5 1 15

17 2 7 10 6 18 8 16 3

12 4 13 11 2 7 14 19

Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA 7 HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps Description GOLD CUP® Series - Open & Closed Circuits

CLOSED HYDRAULIC CIRCUIT Variable Pump/Fixed Motor. This combination provides for a constant torque output at a fixed maximum pressure over the full speed range. Speed and direction are controlled with a variable displacement over-center pump. Power from overhauling loads is regenerated back into the pump prime mover. Motor speed is limited to the maximum speed permitted by full pump displacement. System is capable of full power only at maximum pump displacement. POWER CHARACTERISTICS OF Variable Pump/Variable Motor. This combination provides for an extended range HYDROSTATIC TRANSMISSIONS of motor speeds. The motor, at full displacement, delivers maximum torque while its speed and direction respond to displacement changes of the crossover center pump. Power is proportional to motor speed. This transmission system has the capability of constant torque and rising power until the pump reaches full displacement and full power at elevated speeds as motor displacement and torque are reduced. PACKAGE PUMP The package pump contains the circuit elements shown in the hydraulic schematic on pgs. 72-74. These include the axial piston over-center variable displacement pump which controls the speed and direction of the motor, the auxiliary pump which supplies servo pressure (for controlling the displacement of the variable pump) and replenishment pressure, the servo pressure relief valve, the replenishment pressure relief valve and the replenishment check valves for ports A and B. The pump package also includes the displacement control valves as well as an external arm which shows actual displacement. The various control features are described below.

PACKAGE MOTOR The package motor, shown in schematic pgs. 72-74, contains the axial piston fluid motor, the shuttle valve that continuously removes hot oil from the low pressure side of the loop and a relief valve to establish minimum hydraulic loop pressure at the motor. The fluid motor is available with fixed displacement or with the variable displacement option. The standard variable motors include an external indicator which shows displacement. OPEN CIRCUIT PUMP The open circuit pump contains the circuit elements shown on pages 75,76. These include a cross-center variable displacement pump which is normally limited to one side of center. The auxiliary pump supplies only servo pressure to control the main pump displacement and inlet porting is enlarged to improve the pump’s inlet characteristics. As the open loop pump operates on one side of center only, not all controls are available. AUXILIARY REAR DRIVE Additional auxiliary flow is available with the rear drive pump option. The rear drive may also be utilized for servo and other purposes. See ordering code for additional detail. “R” & “L” style pumps have no rear shaft seal, so any pump driven must be able to withstand case pressure of the pump driving it. AUXILIARY PUMP Integral to the package pump’s envelope is the gerotor auxiliary pump. (P24P, P24S, P30P & P30S have vane integral pump). It provides servo and replenishing pressure. See page 5 for factory settings. NOTE: Auxiliary pump inlet must be connected directly to the reservoir. Customer must supply external line from integral auxiliary pump back into main pump for filtering servo and/or replenishing oil. (see installation drawings starting on pg 10.)

Parker Hannifin Corporation Hydraulic Pump Division 8 Marysville, Ohio USA HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps Description GOLD CUP® Series - Open & Closed Circuits

MOUNTING The pump or motor is designed to operate in any position. For vertical mounting it is recommended that the shaft bearing be drained via the drain port provided. The mounting hub and mounting flange are in full conformance with SAE standard. The shaft must be in alignment with the shaft of the driven load and should be checked with a dial indicator. The mounting pad or adapter into which the fluid pump pilots must be concentric with the pump shaft within 0.006 in., 0,152 mm to prevent bearing failure. This concentricity is particularly important if the shaft is rigidly connected to the driving load without a flexible coupling. The shaft-coupling interface must be lubricated with lithium molydisulfide or similar grease.

INLET PRESSURES, In a closed hydraulic loop the pump inlet or the fluid motor inlet (during dynamic PORTS A & B braking) are supercharged by the integral replenishment system. Consult Parker in cases where fluid viscosity or dynamics or line size may cause inlet pressure at either port A or B to be less than the 150 psi, 10,3 bar maintained by the integral replenishment system. For operation in open loop or combination open- closed loops, consult Parker.

DRAIN PORT Drain the package pump from the higher drain port. If drain port is above the fluid level in the tank install a 5 psi, 0,3 bar relief of suitable size in the drain line to tank. For vertical mounting it is recommended that the shaft bearing be drained via the drain port provided. For pump speeds intermittently below 1000 rpm, install a back pressure relief 40 psi, 2,8 bar of suitable size in the drain line from the higher port to tank. Motor case drain must be connected to pump case. Motor: Drain the motor from the higher drain ports into the lower pump drain port or tank. Make provision that the motor drain port pressure will not exceed the maximum limits specified above.

RETURN LINE FILTER Relatively inexpensive low pressure filters are recommended for installation in the return lines and drain lines from circuits using these pumps or motors. Consider the possibility of decompression surges and intensified flow in cylinder circuits as well as the factors above in selecting return line filters.

AUXILIARY FLOW FILTERS It is recommended the auxiliary pump fluid be filtered to aid in maintaining acceptable cleanliness levels. For good filtration and reasonable maintenance intervals the filter capacity must be at least twice the auxiliary pump flow. To use this feature, install the isolation plug and connect the filter between ports G&H, (P6,P7,P8,P24,P30), or J&K (P11,P14). See detailed schematics and drawings pages 10-22 for location of these ports.

RECOMMENDED FLUIDS The fluid recommended for use in these pumps and motors has a petroleum base and contains agents which provide oxidation inhibition and anti-rust, antifoam and de-areating properties as described in Parker Denison standard HF-1. These preferred fluids do not contain anti-wear additives. Fluids containing anti-wear additives that meet Parker Denison standard HF-0 are acceptable.

VISCOSITY Max. at cold start 7500 SUS, 1600 cSt at low pressure, low flow and if possible, low speed Max. at full power 750 SUS, 160 cSt Optimum for max. life 140 SUS, 30 cSt Minimum at full power 60 SUS, 10cSt

CLEANLINESS Particle contamination to meet ISO 20/17/14 or better. Water content < 500 ppm for mineral based fluids. For detail on fluid recommendations see bulletin SPO-AM305.

Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA 9 HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps P6-P7-P8F, M Dimensions GOLD CUP® Series - Open & Closed Circuits

1.50 6000 PSI SAE- DIA. (38,1) (414 BARS) .72 3.00 3.00 .84 4-BOLT FLG. CONN. DRAIN CONN. (18,3) (76,2) (76,2) (21,3) SAE-12 STR. THD. L3 D1 A "D" CASE DRAIN CONN. SAE-12 STR. THD.

B A

1.56 1.53 (39,6) (38,9) 3.06 3.12 (77,7) (79,2)

D2 ALT. DRAIN CONN. 1.44 1.68 L4 SAE-12 STR. THD. A (36,6) (42,7) L2 1.30 5/8-11UNC x DEEP 2.00 3000 PSI (33,0) SAE- DIA. 4-PLACES (50,8) (207 BARS) L1 4-BOLT FLG. CONN.

MOUNTING 1.05 MOUNTING L1 L2 L3 L4 1/2 -13UNC x DEEP (26,7) SAE 127-2 11.19L1 11.06 L24.90 L3.85 L4 4-PLACES P*F SAE 127-2(SAE-C) 11.19(284,2) (280,9)11.06(124,5) (21,6)4.90 .85 (SAE-C)SAE 152-4 (284,2)11.59 11.46(280,9)5.30 (124,5).89 (21,6) (SAE-D) (294,3) (291,1) (134,6) (22,6) SAE 152-4 11.59 11.46 5.30 .89 (SAE-D) (294,3) (291,1) (134,6) (22,6)

P*M DRAIN CONN. 1.30 SAE-12 STR. THD. 5/8-11 UNC-2B TAP x DP. (33,0) A L3 D1 4 PLACES AS SHOWN

3.12 (79.2) 1.56 (39.6)

3.94 .72 (99,9) .25 (18.3) (6.4) 1.44 (36.6)

3.94 (99,9) SYSTEM PORT A (FAR SIDE) SYSTEM PORT B (NEAR SIDE) 1.50 6000 PSI SAE- DIA. (38.1) (418 BARS) 4-BOLT FLG. CON A D2 ALT. DRAIN CONN. L4 SAE-12 STR. THD. L2 L1 MOUNTING MOUNTING L1 L1 L4L3L2 L4L3L2 SAE 127-2 127-2 13.40 13.4010.14 4.9010.14 .85 4.90 .85 (SAE-C) (340,4) (257,6) (124,5) (21,6) 4.50 (SAE-C) (340,4) (257,6) (124,5) (21,6) (114,3) SAE 152-4 13.80 10.54 5.30 .89 SAE(SAE-D) 152-4 (350,5) 13.80(267,7) (134,6)10.54 (22,6) 5.30 .89 (SAE-D) (350,5) (267,7) (134,6) (22,6)

NOTE: See page 16 for shaft information. 4.50 (114,3) See pages 45-54 for rear drive information.

Parker Hannifin Corporation Hydraulic Pump Division 10 Marysville, Ohio USA HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps P6-P7-P8V, D, P Dimensions (Less Controls) GOLD CUP® Series - Open & Closed Circuits

(NEAR SIDE) AUXILIARY PUMP OUTLET G H AUXILIARY PUMP (FAR SIDE) TO EXTERNAL FILTER & SERVO GAGE CONN. FILTER RETURN PORT SAE-8 STR. THD. SAE-8 STR. THD.

4.50 4.50 A L1 (114,3) (114,3) ALT. DRAIN CONN. K AUXILIARY REPLENISH PORT .72 3.00 3.00 .84 SAE-12 STR. THD. (18,3) (76,2) (76,2) (21,3) L3 D1 SAE-16 STR. THD. L7

5.27 (133,9) 3.87 TYP. (98,3) B A 1.56 1.53 (39,6) (38,9)

3.12 3.06 (79,2) (77,7)

3.70 (93,9)

L4 1.44 1.68 L5 (36,6) (42,7) PORT "B" 1/2-13UNC x 1.05 1.50 6000 PSI L2 SAE- DIA. 4-PLACES (26,7) (38,1) (414 bar) 1.38 A 4-BOLT FLG. CONN 5/8-11UNC x DEEP BG THIS SIDE (35,1) 4-PLACES AG FAR SIDE ALT. DRAIN CONN. D2 C AUXILIARY PUMP INLET MAIN LOOP GAGE CONN. SAE-12 STR. THD. ® PORT "A" SAE-16 STR. THD. SAE-6 STR. THD. 6.0 & 7.25 GOLD CUP 2.00 3000 PSI SAE- DIA. P*V (50,8) (207 bar) TABLE 1 TABLE 1 4-BOLT FLG. CONN P*V MOUNTING L1 L2 L7L5L4L3 MOUNTING L1 L2 L7L5L4L3 SAE 127-2 15.51 13.70 7.02 1.00 10.64 5.15 P*D & P*P (SAE-C) (393,9) (348,0) (178,3) (25,4) (270,3) (130,9) SAE 152-4 16.85 15.04 8.36 .86 11.98 6.49 (SAE-D) (427,9) (382,1) (212,3) (21,8) (304,3) (164,8)

(NEAR SIDE) AUXILIARY PUMP OUTLET G H AUXILIARY PUMP (FAR SIDE) TO EXTERNAL FILTER & SERVO GAGE CONN. FILTER RETURN PORT SAE-8 STR. THD. SAE-8 STR. THD. 4.50 4.50 A L1 (114,3) (114,3) ALT. DRAIN CONN. K AUXILIARY REPLENISH PORT .72 3.00 3.00 .72 SAE-12 STR. THD. (18,3) (76,2) (76,2) (18,3) L3 D1 SAE-16 STR. THD. L7

5.27 (133,9) 3.87 TYP. (98,3) B A 1.56 1.56 (39,6) (39,6)

3.12 3.12 (79,2) (79,2)

3.70 (93,9)

L4 1.44 1.44 L5 (36,6) (36,6) 1.38 1.50 6000 PSI 5/8-11UNC x DEEP L2 SAE- DIA. (35,1) (38,1) (414 bar) 8-PLACES A 4-BOLT FLG. CONN BG THIS SIDE TYP. PORTS "A" & "B" AG FAR SIDE ALT. DRAIN CONN. D2 C AUXILIARY PUMP INLET MAIN LOOP GAGE CONN. SAE-12 STR. THD. NOTE: See page 16 for shaft information. SAE-16 STR. THD. SAE-6 STR. THD. See appropriate controls mounting starting on page 34.

Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA 11 HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps P6-P7-P8X, R Dimensions (Less Controls) GOLD CUP® Series - Open & Closed Circuits

(NEAR SIDE) AUXILIARY PUMP OUTLET G H AUXILIARY PUMP (FAR SIDE) K AUXILIARY REPLENISH AND TO EXTERNAL FILTER & SERVO GAGE CONN. FILTER RETURN PORT PUMP FILTER RETURN PORT SAE-8 STR. THD. SAE-8 STR. THD. SAE-12 STR. THD. L6 A SYSTEM PORT A (FAR SIDE) ALT. DRAIN CONN. SYSTEM PORT B (NEAR SIDE) 5.38 5.38 SAE-12 STR. THD. (136,5) (136,5) L3 D1 SEE DETAIL "A" L7

5.27 (133,9)

3.87 (98,3)

.90 (23,0) .90 B A (23,0) 3.87 (98,3) 3.70 (93,9)

3.38 R (85,8)

1.44 ALT. DRAIN CONN. D2 (36,6) SAE-12 STR. THD. 1.31 L4 .72 5/8 -11UNC-2B THREAD x DEEP L5 (18,3) 8-PLACES (33,3) A L2 L1 1.56 C AUXILIARYC AUXILIARY PUMP INLET PUMP INLET (39,7) SAE-16 STR.SAE-16 THD. STR. THD. 3.13 TABLE 3 (79,4) TABLE 3 MOUNTING L1 L2 L3L4 L5 L6 L7 MOUNTING L1 SAE 127-2L217.27 L315.14 L47.02 1.00 L5 10.64 L616.58 5.15L7 (SAE-C) (438,6) (384,6) (178,3) (25,4) (270,3) (421,2) (130,9) 7.02 1.00 10.64 16.58 5.15 SAE 127-2 17.27 SAE 15.14152-4 18.61 16.48 8.36 .86 11.98 17.92 6.49 SYSTEM PORT A (FAR SIDE) (SAE-C) (438,6) (SAE-D)(384,6) (472,6)(178,3)(418,6) (25,4)(212,3) (21,8)(270,3) (304,3)(421,2)(455,2) (164,8)(130,9) SYSTEM PORT B (NEAR SIDE) SAE 152-4 18.61 16.48 8.36 .86 11.98 17.92 6.49 P*X (SAE-D) (418,6) 1.50 6000 PSI (472,6) (212,3) (21,8) (304,3) (455,2) (164,8) SAE- DIA. (38,1) (414 BARS) 4-BOLT4 BOLT FLG. CONNECTION

1.30 5/8-11 UNC-2B TAP x DP. P*R D1 DRAIN CONN. (33,0) 4 PLACES AS SHOWN SAE-12 STR. THD. L1 3.12 A (79.2) 1.56 L3 (39.6) L7 .72 (18.3)

1.44 (36.6) 6.07 (154,1)

3.87 .25 (98,3) (6.3) SYSTEM PORT A (FAR SIDE) SYSTEM PORT B (NEAR SIDE) 1.50 6000 PSI SAE- DIA. (38.1) (418 BARS) 3.87 4-BOLT FLG. CON 3.70 TABLE 2 (98,3) (94,0) MOUNTING L1 L2 L3 L4 L7L6L5 SAE 127-2 15.51 11.88 7.02 1.00 10.64 15.14 5.15 (SAE-C) (393,9) (301,8) (178,3) (25,4) (270,3) (384,6) (130,9) SAE 152-4 16.85 13.22 8.36 .86 11.98 16.48 6.49 (SAE-D) (427,9) (335,9) (212,3) (21,8) (304,3) (418,7) (164,8)

L4 ALT. DRAIN CONN. D2 H SERVO GAGE CONN. SAE-12 STR. THD. SAE-4 STR. THD. L5 REAR ADAPTER A L2 L6 (38.1) (418 BARS) B1 SYSTEM GAGE CONN. K REPLENISHING PORT INLET SAE-6 STR. THD. SAE-16 STR. THD. TABLE 2 4-BOLT FLG. CON MOUNTING L1 L2 L3 L4 L7L6L5 15.51 15.14 5.15 4.50 SAE 127-2 11.88 7.02 1.00 10.64 4.50 G CONTROL PRESSURE INLET (114,3) (SAE-C) (393,9) (301,8) (178,3) (25,4) (270,3) (384,6) (130,9) (114,3) SAE-8 STR. THD. SAE 152-4 16.85 13.22 8.36 .86 11.98 16.48 6.49 (SAE-D) (427,9) (335,9) (212,3) (21,8) (304,3) (418,7) (164,8)

4.50 A1 SYSTEM GAGE CONN. (114,3) SAE-6 STR. THD. 4.50 NOTE: See page 16 for shaft information. (114,3) See pages 45-54 for rear drive information. 6.02 (152,8) See appropriate controls mounting starting on page 34.

Parker Hannifin Corporation Hydraulic Pump Division 12 Marysville, Ohio USA HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps P6-P7-P8S, L Dimensions (Less Controls) GOLD CUP® Series - Open & Closed Circuits

(NEAR SIDE) AUXILIARY PUMP OUTLET G H AUXILIARY PUMP (FAR SIDE) TO EXTERNAL FILTER & SERVO GAGE CONN. FILTER RETURN PORT SAE-8 STR. THD. SAE-8 STR. THD. L6 A ALT. DRAIN CONN. L3 SAE-12 STR. THD. "BG" SYS. GAGE (N.S.) D1 "AG" SYS. GAGE (F.S) L7 SAE-6 STR. THD.

5.27 (133,9)

3.87 (98,3) SYSTEM PORT A (FAR SIDE) SYSTEM PORT B (NEAR SIDE) SEE DETAIL "A"

1.31 5/8 -11UNC-2B THREAD x DEEP 8-PLACES (33,3)

3.87 1.44 (98,3) 3.70 (93,9) (36,6) .72 (18,3) 6.51 (165,4)

ALT. DRAIN CONN. D2 1.56 L4 SAE-12 STR. THD. (39,7) L5 3.13 C AUXILIARY PUMP INLET (79,4) A SAE-16 STR. THD. L2 L1 DETAIL "A" SYSTEM PORTS A & B 1.50 6000 PSI SAE- DIA. (38,1) (414 BARS) 4-BOLT FLG. CONNECTION

TABLE 5 4.50 5.38 (114,3) (136,5) TABLE 5 MOUNTING L1 L2 L3 L4 L5 L6 L7 5.15 SAEMOUNTING 127-2 19.97 15.14 7.02 1.00 10.64 16.58 (SAE-C) (507,3) (384,6)L1(178,3) L2(25,4) (270,3)L3(421,2) L4(130,9) L5 L6 L7 SAESAE 152-4 127-2 21.31 16.4819.97 8.36 15.14.86 11.987.02 17.92 1.006.49 10.64 16.58 5.15 (SAE-D) (541,3) (418,6) (212,3) (21,8) (304,3) (455,2) (164,8) (SAE-C) (507,3) (384,6) (178,3) (25,4) (270,3) (421,2) (130,9)

4.50 5.38 SAE 152-4 21.31 16.48 8.36 .86 11.98 17.92 6.49 (114,3) (136,5) (SAE-D) (541,3) (418,6) (212,3) (21,8) (304,3) (455,2) (164,8)

"D3" DRAIN CONNECTION P*S "KA" SHUTTLE SAE-16 STR. THD. RELIEF INLET SAE-12 STR. THD.

G SERVO PRESSURE INLET ALT. DRAIN CONN. SAE-8 STR. THD. SAE-12 STR. THD. D1 P*L K AUXILIARY REPLENISH AND PUMP FILTER RETURN PORT SAE-12 STR. THD. A L5 L3 REAR ADAPTER L7

5.27 (133,9) 1.44 3.87 (36,6) TYP. (98,3) .72 (18,3)

2.04 (51,8) 1.56 (39,7) 3.13 7.38 (79,4) (187,6)

1.31 SYSTEM PORT A (FAR SIDE) 5/8 -11UNC-2B THREAD x DEEP (33,3) SYSTEM PORT B (NEAR SIDE) 8-PLACES ALT. DRAIN CONN. D2 1.50 6000 PSI SAE-12 STR. THD. SAE- DIA. L4 (38,1) (414 BARS) 4-BOLT FLG. CONNECTION A L2 L1 TABLE 4 "D3" DRAIN CONNECTION SAE-16 STR. THD. "KA" SHUTTLE RELIEF INLET SAE-12 STR. THD. TABLEMOUNTING 4 L1 L2 L3 L4 L5 L6 L7 MOUNTING SAE 127-2 L1 17.58L2 L315.14L4 L57.02 L6 1.00L7 10.58 16.58 5.15 SAE 127-2 17.58 15.14 7.02 1.00 10.58 16.58 5.15 (SAE-C)(SAE-C)(446,6) (384,6)(446,6) (178,3)(384,6)(25,4) (268,8)(178,3)(421,2) (25,4)(130,9) (268,8) (421,2) (130,9) SAE 152-4 18.92 16.48 8.36 .86 11.92 17.92 6.49 4.50 SAE 152-4 18.92 16.48 8.36 .86 11.92 17.92 6.49 5.38 (SAE-D) (480,6) (418,6) (212,3) (21,8) (302,8) (455,2) (164,8) (114,3) (136,5) (SAE-D) (480,6) (418,6) (212,3) (21,8) (302,8) (455,2) (164,8)

5.32 (135,1)

5.32 (135,1) NOTE: See page 16 for shaft information. 4.50 (114,3) See pages 45-54 for rear drive information. 5.38 (136,5) See appropriate controls mounting starting on page 34.

Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA 13 HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps M6-M7-M8 F, G, M, N Dimensions GOLD CUP® Series - Open & Closed Circuits

M*F & M*G MOUNTING L2L1 L3 L4 SAE 127-2 11.19 11.06 4.90 .85 (SAE-C) (284,2) (280,9) (124,5) (21,6) SAE 152-4 11.59 11.46 5.30 .89 (SAE-D) (294,3) (291,1) (134,6) (22,6)

DRAIN CONN. SAE-12 STR. THD. A L3 D1 .72 3.00 3.00 "D" CASE DRAIN CONN. (18,3) (76,2) (76,2) SAE-12 STR. THD.

B A

1.56 (39,6)

3.12 (79,2)

4.56 (115,8) "M*G" ONLY

D2 ALT. DRAIN CONN. 1.50 6000 PSI 1.44 SAE- L4 SAE-12 STR. THD. DIA. A (36,6) (38,1) (418 BARS) 4-BOLT FLG. CONN L2 1.30 5/8-11UNC x DEEP L1 8-PLACES (33,0) M*M & M*N REAR ADAPTER M*M & M*N DRAIN CONN. 1.30 5/8-11 UNC-2B TAPx DP. SAE-12 STR. THD. (33,0) A L3 D1 4 PLACES AS SHOWN

3.12 (79.2) 1.56 (39.6)

3.94 .72 (99,9) .25 (18.3) (6.4) 1.44 (36.6)

3.94 (99,9) 5.67 PORTS A & B (144,0) 1.50 6000 PSI "M*N" ONLY SAE- DIA. (38.1) (418 BARS) 4-BOLT FLG. CON

D2 ALT. DRAIN CONN. L4 SAE-12 STR. THD. A L2 PORT "A"- FAR SIDE PORT "B"- THIS SIDE L1 SEE PORT DETAIL

MOUNTING 4.50 L1 L2L1L3 L2 L4 L3 L4 (114,3) SAE 127-2 13.40 10.14 4.90 .85 SAE(SAE-C) 127-2 (340,4) (257,6)13.40 (124,5) 10.14(21,6) 4.90 .85 SAE(SAE-C) 152-4 13.80 10.54(340,4)5.30 (257,6).89 (124,5) (21,6) (SAE-D) (350,5) (267,7) (134,6) (22,6) SAE 152-4 13.80 10.54 5.30 .89 (SAE-D) (350,5) (267,7) (134,6) (22,6)

NOTE: See page 16 for shaft information. 4.50 See pages 45-54 for rear drive information. (114,3)

Parker Hannifin Corporation Hydraulic Pump Division 14 Marysville, Ohio USA HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps M6-M7-M8 H, V, R, L Motor Dimensions (Less Controls) GOLD CUP® Series - Open & Closed Circuits

M*H & M*V TABLE 14 MOUNTING L1 L2 L3 L4 L7L5 SAE 127-2 13.16 12.80 7.02 1.00 10.58 5.15 (SAE-C) (334,3) (325,1) (178,3) (25,4) (268,8) (130,9) SAE 152-4 14.50 14.14 8.36 .86 11.92 6.49 (SAE-D) (368,3) (359,2) (212,3) (21,8) (302,8) (164,8)

D CASE DRAIN PORT H2 CONTROL PRESSURE INLET H1 CONTROL PRESSURE INLET SAE-12 STR. THD. SAE-8 STR. THD. (FAR SIDE) SAE-8 STR. THD. (NEAR SIDE) 4.50 4.50 L3 (114,3) (114,3) A ALT. DRAIN CONN. .72 3.00 3.00 L7 SAE-12 STR. THD. D1 (18,3) (76,2) (76,2)

3.87 (98,3) B A 1.56 1.16 (39,6) (29,5) 3.12 (79,2) 3.87 4.56 (98,3) (115,8) "M*H" ONLY

1.44 1.50 6000 PSI L4 ALT. DRAIN CONN. D2 SAE- DIA. (36,6) A SAE-12 STR. THD. (38,1) (414 bar) 1.38 4-BOLT FLG. CONN 5/8-11UNC x DEEP 2-PLACES L5 (35,1) L2 8-PLACES L1 M*R & M*L M*R & M*L REAR ADAPTER L3

D1 DRAIN CONN. A L7 1.30 SAE-12 STR. THD. 5/8-11 UNC-2B TAP x DP. (33,0) 4 PLACES AS SHOWN

3.12 (79.2) 1.56 3.87 .25 (39.6) (98,3) (6.3) .72 (18.3)

1.44 (36.6) 1.94 3.87 (49,3) (98,3)

H1 SYSTEM PORT A (FAR SIDE) 5.67 SYSTEM PORT B (NEAR SIDE) (144,0) 1.50 6000 PSI SAE- DIA. "M*L" ONLY (38.1) (418 BARS) ALT. DRAIN CONN. D2 4-BOLT FLG. CON A SAE-12 STR. THD.

H1 CONTROL PRESSURE INLET L3 SAE-8 STR. THD. (NEAR SIDE) L2 H2 CONTROL PRESSURE INLET L1 SAE-8 STR. THD. (FAR SIDE)

TABLE 13

4.50 MOUNTING L1L2 L3 L4 L5 L7 4.50 (114,3) (114,3) SAE 127-2 15.14 11.88 7.02 1.00 10.36 5.15 TABLE 13 (SAE-C) (384,6) (301,8) (178,3) (25,4) (263,1) (130,9) MOUNTING L1L2 L3 L4 L5 L7 SAESAE 127-2 152-415.14 11.8816.48 7.02 13.221.00 10.36 8.365.15 .86 11.70 6.49 (SAE-C) (384,6) (301,8) (178,3) (25,4) (263,1) (130,9) SAE 152-4(SAE-D)16.48 13.22(418,7)8.36 (335,9).86 11.70 (212,3)6.49 (21,8) (397,2) (164,8) (SAE-D) (418,7) (335,9) (212,3) (21,8) (397,2) (164,8)

4.50 (114,3) 4.50 NOTE: See page 16 for shaft information. (114,3) See pages 45-54 for rear drive information. See appropriate controls mounting starting on page 34.

Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA 15 HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps For 6-7-8 Pumps & Motors GOLD CUP® Series - Open & Closed Circuits

M*F, M*G, M*H, M*V, P*S, P*X, P*D, P*P, P*V & P*F M*R, M*L, M*M, M*N, P*L & P*R

2.97 2.91 S1 75,4 ( 73,9 ) .49 (12,4) .78 (M10 x 1.5) METRIC THREAD x DEEP .25 .83 (19,8) S2 MAX. (6,4) (21,1) 1.71 SPLINE LENGTH S3 (43,4) 4.50 (114,3) .12 (3,0) 3.18 6.000 5.998 (80,8) 30˚ DIA. 152,40 (152,35 ) 1.943 2.76 (49,35) DIA. (70,1)

30˚ 6.36 1.7500 1.7494 (161,6) DIA. 44,45 ( 44,43 ( 4.50 .12 (114,3) (3,0) .06 x 45˚ .31 (1,5) FOR SAE 152-4 (7,9) 3.18 ("D" 4-BOLT) (80,8) SAE 152-4 ("D" 4 BOLT) SAE 152-4 ("D" 4 BOLT) 6.36 (161,6) SAE 44-1 SAE 44-4 4.44 (112,8) ("D" KEYED) ("D" SPLINE) 8.88 (225,6) SHAFT DEGIGNATION SHAFT SHAFT DEGIGNATION SAE INVOLUTE SPLINE J498-B 1969 PUMP MODEL CODE S2S1 S3 PUMP MODEL CODE EXTERNAL CLASS 1 FLAT ROOT SIDE FIT 2.97/2.91 2.64 734./834. 57.1 04 SAE 44-1 SQ. KEY x 8/16 DIA. PITCH (SAE-D Key) (75,4/73,9) (67,0) (11,12/11,10) (44,4) 30˚ PRESSURE ANGLE 05 13 TEETH 1.7210-1.7160 MAJOR DIA (43,713/43,586)

2.23 2.23 2.15 2.15 .78 (M10 x 1.5) METRIC THREAD x DEEP 56,6 56,6 (19,8) ( 54,6 ) ( 54,6 ) FOR SAE 127-2 .49 1.19 ("C" 2-BOLT) SPLINE LENGTH (12,4) (30,2) SEE NOTE 1 .24 8.50 .73 DIA. 1.75 (18,4) S1 (6,1) SPLINE LENGTH (215,9) (44,5) SEE NOTE 2 S2 S3 .09 (2,3) 4.22 3.56 1.386 (107,2) 4.50 (90,4) (35,20) DIA. 30˚ (114,3)

5.000 4.998 DIA. 30˚ 127,00 ( 126,95 ) 1.2500 7.12 4.22 1.2494 DIA. (180,8) (107,2) 31,750 ( 31,735 ) .09 .06 (2,3) x 45˚ (1,5) 1.30 DIA. .31 NOTES: (33,0) MIN. SAE 127-2 ("C" 2-BOLT) (7,9) 1. SPLINE LENGTH ONLY FOR: SAE 127-2 ("C" 2-BOLT) M*F, M*G, M*H, M*V, P*S, P*X, P*D, P*P, P*V & P*F SAE 32-1 2. SPLINE LENGTH ONLY FOR: SAE 32-4 ("C" KEYED) M*R, M*L, M*M, M*N, P*L & P*R ("C" SPLINE) SHAFT DEGIGNATION SHAFT DEGIGNATION SHAFT SAE INVOLUTE SPLINE J498-B 1969 PUMP MODEL CODE S1 S2 S3 PUMP MODEL CODE EXTERNAL CLASS 1 FLAT ROOT SIDE FIT 2.23/2.15 1.88 .312/.310 1.25/1.22 12/24 DIA. PITCH SAE 32-1 SQ. KEY x LG. 02 or 07 (SAE-C) (56,6/54,6) (47,8) (7,92/7,87) (31,8/31,0) 30˚ PRESSURE ANGLE 03 or 08 14 TEETH SAE 32-1 LONG 3.36/3.28 3.01 .312/.310 2.38/2.35 1.2293-1.2243 09 or 10 SQ. KEY x LG. MAJOR DIA (SAE-C) (85,3/83,3) (76,4) (7,92/7,87) (60,4/59,7) (31,224/31,097)

Parker Hannifin Corporation Hydraulic Pump Division 16 Marysville, Ohio USA HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps P11-P14 M, F Dimensions GOLD CUP® Series - Open & Closed Circuits

16.28 (413,4) REAR ADAPTER 6.12 (155.4) 1.12 B (28.4) "D1" DRAIN CONN. SAE-16 STR. THD.

4.82 (122,4)

B

5.91 (150,0)

"D2" ALT. DRAIN CONN. 3.13 SAE-16 STR. THD. (79,4) B 1.56 5.94 5.94 13.60 (39,7) (345,4) (150,9) (150,9)

1.44 (36,6)

1.31 5/8 -11UNC-2B THREAD x DEEP .72 8-PLACES (33,3) (18,3) P*M SYSTEM PORT A (FAR SIDE) SYSTEM PORT B (NEAR SIDE) 1.50 6000 PSI SAE- DIA. (38,1) (414 BAR) 4-BOLT FLG. CONNECTION

P*F

16.51 (419,4) 1.31 15.28 5/8-11UNC-2B THREAD x DEEP (33,3) (388,0) 8-PLACES 6.12 1.44 1.44 (155.4) 1.12 (36.4) (36.4) "D1" ALT. DRAIN CONN. .72 B (28.4) .72 SAE-16 STR. THD. (18.3) 3.00 3.00 (76.2) (76.2) (18.3) A 4.82 B (122,4)

1.56 (39,6) 3.12 (79,2)

4.82 (122,4)

"D2" ALT. DRAIN CONN. "D" DRAIN CONNECTION SAE-16 STR. THD. SAE-1.50 6000 P.S.I. DIA. SAE-16 STR. THD. B (38.1) (414 bar) 4-BOLT FLG. CONN. (CODE 62) 2-PLACES

NOTE: See page 23 for shaft information. See pages 45-54 for rear drive information.

Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA 17 HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps P11-P14 P, V Dimensions (Less Controls) GOLD CUP® Series - Open & Closed Circuits

6000 P.S.I. SAE-1.50 DIA. (38.1) (415 bar) 4-BOLT FLG. CONN. (CODE 62)

TYPICAL 2-PLACES 1.44 (36,6) L1 .72 3.00 3.00 (18,3) (76,2) (76,2) 1.12 B L3 "D1" DRAIN CONN. (28,4) SAE-16 STR. THD.

5.83 5.17 (148,0) (131,3) B A

1.56 (39,6) 3.12 (79,2)

5.17 4.91 (131,3) (124,7) 5.33 (135,3)

"D2" ALT. DRAIN CONN. 5.56 5.56 B L7 SAE-16 STR. THD. 141,3 ( 141,3 ) 1.38 5/8-11UNC-2B x DEEP 8-PLACES (35,1) L4 "C" AUXILIARY PUMP INLET SAE-20 STR. THD. P*P L2 TABLE 6 PUMP L1 L2 L3 L7L4 P11P, P14P 19.83 18.31 8.48 15.25 6.38 & (503,8) (465,2) (215,3) (387,4) (162,0) 6000 P.S.I. P11V, P14V SAE-1.50 DIA. P*V (38.1) (415 bar) 4-BOLT FLG. CONN. (CODE 62) 1.44 2.00 (36,6) (50,8) L1 .72 3.00 3.25 1.00 (18,3) (76,2) (82,6) (25,4) 1.12 L3 B "D1" DRAIN CONN. (28,4) SAE-16 STR. THD.

5.83 5.17 (148,0) (131,3) BA

1.56 1.75 (44,4) (39,6) 3.50 3.12 (88,9) (79,2)

5.17 4.91 (131,3) (124,7) 5.33 (135,3)

"D2" ALT. DRAIN CONN. 5.56 5.56 B L7 SAE-16 STR. THD. 141,3 ( 141,3 ) 2.50 2500 PSI DIA. 4-BOLT FLG. (63,5) (172 BARS) L4 "C" AUXILIARY PUMP INLET 1.38 1.19 SAE-20 STR. THD. 5/8-11UNC-2B x DEEP 1/2-13UNC-2B x DEEP L2 4-PLACES (35,1) 4-PLACES (30,2)

NOTE: See page 23 for shaft information. See appropriate controls mounting starting on page 34.

Parker Hannifin Corporation Hydraulic Pump Division 18 Marysville, Ohio USA HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps P11-P14 S, X Dimensions (Less Controls) GOLD CUP® Series - Open & Closed Circuits

"K" AUXILIARY REPLENISH AND PUMP FILTER RETURN PORT SAE-12 STR. THD. L5

1.12 L3 B "D1" DRAIN CONN. (28,4) SAE-16 STR. THD.

3.38 R (85,8)

5.83 5.17 (148,0) (131,3)

.90 (23,0) .90 B A (23,0) 4.91 (124,7) 5.17 6.51 (131,3) (165,4)

L7 "D2" ALT. DRAIN CONN. B SAE-16 STR. THD. L4 5.38 5.38 (136,5) (136,5) L2 5.56 5.56 141,3 (141,3 ) P*S "C"L1 AUXILIARY PUMP INLET 1.44 (36,6) SAE-20 STR. THD. "C" AUXILIARY PUMP INLET .72 TABLE 7 SAE-20 STR. THD. 1.31 (18,3) 5/8 -11UNC-2B THREAD x DEEP TABLE 7 8-PLACES (33,3) PUMP P*S L2L1 PUMP L5L4L3 L2L1 L7 L5L4L3 L7 24.58 24.58 P*S P*S 8.48 (624,4) 19.75 8.48 15.25 21.19 6.38 1.56 (624,4) 19.75 15.25 21.19 6.38 (39,7) 21.88 (501,7) (215,3) (387,4) (538.3) (162,0) P*X 3.13 21.88 (501,7) (215,3) (387,4)(555,7)(538.3) (162,0) P*X (79,4) P*X (555,7) "K" AUXILIARY REPLENISH AND PUMP FILTER RETURN PORT SAE-12 STR. THD. P*X SYSTEM PORT A (FAR SIDE) L5 SYSTEM PORT B (NEAR SIDE) 1.50 6000 PSI SAE- DIA. (38,1) (414 BARS) 1.12 L3 B "D1" DRAIN CONN. 4-BOLT FLG. CONNECTION (28,4) SAE-16 STR. THD.

3.38 R (85,8)

5.83 5.17 (148,0) (131,3)

.90 (23,0) .90 B A (23,0)

5.17 4.91 (131,3) (124,7) 5.33 (135,3)

5.38 5.38 L7 "D2" ALT. DRAIN CONN. (136,5) (136,5) B SAE-16 STR. THD. L4 5.56 5.56 ( ) L2 141,3 141,3 L1 "C" AUXILIARY PUMP INLET SAE-20 STR. THD.

NOTE: See page 23 for shaft information. See pages 45-53 for rear drive information. See appropriate controls mounting starting on page 34.

Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA 19 HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps P11-P14 R, L Dimensions (Less Controls) GOLD CUP® Series - Open & Closed Circuits

3.13 (79,4) 1.31 1.56 5/8 -11UNC-2B THREAD x DEEP P*R & P*LP*R & P*L (39,7) 8-PLACES (33,3) 1.44 (36,6) TABLE 8 TABLE 8 .72 PUMP L1PUMP L1L2 L2 L3L3 L7L4 L7L4 (18,3) 18.31 15.64 8.48 18.31 6.38 SYSTEM PORT A (FAR SIDE) P*R & P*L 18.31 (465,2)15.64(397,1) 8.48(215,3) (465,2)18.31(162,0) 6.38 P*R & P*L SYSTEM PORT B (NEAR SIDE) (465,2) (397,1) (215,3) (465,2) (162,0) 1.50 6000 PSI SAE- DIA. (38,1) (414 BARS) 4-BOLT FLG. CONNECTION REAR ADAPTER EXTERNAL SERVO SUPPLY L4 INLET CONN. "G2" 5.15 (NEAR & FAR SIDES) (130,8) SAE-8 STR. THD. B "D1" DRAIN CONN. SAE-16 STR. THD.

5.17 (131,3)

1.73 (43,9)

5.17 (131,3) 5.91 (150,0) "P*R" ONLY SHOWN IN PHANTOM

8.08 (205,1) "P*L" ONLY 1.12 "D2" ALT. DRAIN CONN. SHOWN B (28,4) SAE-16 STR. THD. L7 L3

L2 "K" AUXILIARY REPLENISH (NEAR & FAR SIDES) L1 SAE-12 STR. THD. SYSTEM PORT B REF.

5.94 (150,9) 5.56 ( 141,3 )

5.94 5.56 (150,9) ( 141,3 )

SYSTEM PORT A REF. NOTE: See page 23 for shaft information. See pages 45-53 for rear drive information. See appropriate controls mounting starting on page 34.

Parker Hannifin Corporation Hydraulic Pump Division 20 Marysville, Ohio USA HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps M11-M14 H, V, F, G Dimensions (Less Controls) GOLD CUP® Series - Open & Closed Circuits

11-14 MOTOR DIMENSIONS 6000 P.S.I. SAE-1.50 DIA. (38.1) (415 bar) 4-BOLT FLG. CONN. (CODE 62) 1.31 5/8-11 UNC-2B THREAD x DEEP 2-PLACES 8-PLACES (33,3) 3.00 3.00 L4 (76.2) (76.2) 1.44 (36.4) 1.44 (36.4) "D1" ALT. DRAIN CONN. .72 1.12 L3 .72 B SAE-16 STR. THD. (18.3) (28.4) (18.3)

"H1" (NEAR SIDE) "H2" (FAR SIDE) CONTROL PRESSURE INLET SAE-8 STR. THD. 2-PLACES 5.17 (131.3) B A

1.43 1.56 (36.3) (39,6) 3.12 (79,2)

5.17 (131.3)

2.75 5.56 5.56 "D2" ALT. DRAIN CONN. (69,8) B L7 SAE-16 STR. THD. 141,3 ( 141,3 ) "D" DRAIN CONNECTION L2 SAE-12 STR. THD. TABLE 15 L1 MOTOR L1 L2 L3 L4 L7 M11H, M11V 17.79 17.32 8.48 14.56 6.38 & (451.9) (439.9) (215,3) (369,9) (162,0) M*H & M*V M14H, M14V

6000 P.S.I. M*F & M*G SAE-1.50 DIA. (38.1) (414 bar) 4-BOLT FLG. CONN. (CODE 62) 1.31 5/8-11UNC-2B THREAD x DEEP 2-PLACES 16.51 8-PLACES (33,3) (419,4) 3.00 3.00 15.28 (76.2) (76.2) (388,0) 6.12 1.44 1.44 (155.4) 1.12 (36.4) (36.4) B "D1" ALT. DRAIN CONN. .72 (28.4) SAE-16 STR. THD. .72 (18.3) (18.3) A 4.82 B (122,4)

1.56 (39,6) 3.12 (79,2)

4.82 (122,4)

"D2" ALT. DRAIN CONN. SAE-16 STR. THD. SHUTTLE ("M*G" ONLY) "D" DRAIN CONNECTION B SAE-16 STR. THD.

NOTE: See page 23 for shaft information. See appropriate controls mounting starting on page 34.

Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA 21 HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps M11-M14 M, N, R, L Dimensions (Less Controls) GOLD CUP® Series - Open & Closed Circuits

16.28 (413,4) REAR ADAPTER 6.12 (155.4) 1.12 B (28.4) "D1" DRAIN CONN. SAE-16 STR. THD.

4.82 (122,4)

B

5.91 (150,0) "M*M" ONLY SHOWN IN PHANTOM

7.72 (196,1) "M*N" ONLY SHOWN B "D2" ALT. DRAIN CONN. SAE-16 STR. THD.

13.60 5.94 5.94 (345,4) (150,9) (150,9)

3.13 (79,4) 1.31 1.56 5/8 -11UNC-2B THREAD x DEEP M*M & M*N (39,7) 8-PLACES (33,3) 1.44 (36,6)

.72 (18,3) M*R & M*L SYSTEM PORT A (FAR SIDE) SYSTEM PORT B (NEAR SIDE) 1.50 6000 PSI SAE- DIA. (38,1) (414 BARS) 4-BOLT FLG. CONNECTION ALTERNATE EXTERNAL SERVO SUPPLY INLET CONN. "G2" B SAE-8 STR. THD. 5.15 "D1" DRAIN CONN. (130,8) SAE-16 STR. THD.

5.17 (131,3)

1.73 (43,9)

5.17 (131,3) 5.91 (150,0) "M*R" ONLY SHOWN IN PHANTOM

7.72 (196,1) "M*L" ONLY "D2" ALT. DRAIN CONN. SHOWN B L7 SAE-16 STR. THD. L3 L2 L1 REAR ADAPTER SYSTEM PORT B REF. 1.12 TABLE 16 (28,4) TABLE MOTOR16 L1 L2 L3 L4 L7 M11R,MOTOR M11L 18.31 15.64 8.48 14.56 6.38 & (465,2)L1(397,1) L2(215,3) L3(369,9) (162,0) L4 L7 5.94 M14R, M14L (150,9) M11R, M11L 15.64 8.48 5.56 18.31 14.56 6.38 ( 141,3 ) & (465,2) (397,1) (215,3) (369,9) (162,0) M14R, M14L

5.94 5.56 (150,9) ( 141,3 ) NOTE: See page 23 for shaft information. See pages 45-54 for rear drive information. See appropriate controls mounting starting on page 34.

SYSTEM PORT A REF. Parker Hannifin Corporation Hydraulic Pump Division 22 Marysville, Ohio USA HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps For 11-14 Pumps & Motors GOLD CUP® Series - Open & Closed Circuits

M*F, M*G, M*H, M*V, P*S, P*X, P*P, P*V & P*F M*R, M*L, M*M, M*N, P*L & P*R

2.97 2.90 2.97 75,4 2.90 73,7 .625 75,4 .605 73,7 15,88 15,37 1.62 S1 1.50 SPLINE LENGTH SPLINE LENGTH (41,1) (38,1) SEE NOTE 1 .36 SEE NOTE 2 (9.1) .09 (2,3)

S3

.09 (2,3) 6.500 6.498 DIA. 165.1 1.941 165.0 2.75 NECK (49,30) (69.8) SEE NOTE 1 DIA. 30˚ 30˚ 1.7500 1.7495 DIA. 44,45 44,43 .06 x 45˚ (1,5)

SAE 165-4 ("E" 4-BOLT) SAE 165-4 ("E" 4-BOLT) SAE 165-4 ("E" 4-BOLT) SAE 44-4 SAE 165-4 SAE("E" 44-1 4-BOLT) SAE 44-4 SAE 44-1 ("E" SPLINE) ("E" KEYED) ("E" SPLINE) ("E" KEYED) SHAFT DEGIGNATION SAE INVOLUTE SPLINE DATA J498B 1969 SHAFTPUMP MODEL DEGIGNATION CODE FLAT ROOT SIDE FIT SAEEXTERNAL INVOLUTE CLASS 1 SPLINESHAFT DATA DEGIGNATION J498B 1969 PUMP MODEL CODE SHAFT S1 S3 PUMP MODEL CODE8/16 PITCH FLAT ROOT SIDE FIT EXTERNAL CLASSSAE 1 44-1 2.97/2.90 .437/.435 1.50 30˚ PRESSURE ANGLE 02 or 07 SQ. KEY x LG. VIEW B-B 03 or 08 13 TEETH (SAE-E) (75,4/73,7) (11,10/11.05) (38,1) NOTES: 8/16 PITCH 1.7210-1.7160 SAE 44-1 LONG 3.97/3.90 .437/.435 2.50 MAJOR DIA. 09 or 10 SQ. KEY x LG. 1. SPLINE LENGTH AND NECK ONLY FOR: (43,713-43,586) 30˚ PRESSURE ANGLE (SAE-E) (100,8/99,1) (11,10/11.05) (63,5) M*F, M*G, M*H, M*V, P*S, P*X, P*P, P*V & P*F 2. SPLINE LENGTH ONLY FOR: 03 or 08 13 TEETH M*R, M*L, M*M, M*N, P*L & P*R 1.7210-1.7160 MAJOR DIA. (43,713-43,586)

SHAFT DEGIGNATION PUMP MODEL CODE SHAFT S1 S3 2.97/2.90 .437/.435 1.50 SAE 44-1 SQ. KEY x LG. 02 or 07 (SAE-E) (75,4/73,7) (11,10/11.05) (38,1) SAE 44-1 LONG 3.97/3.90 .437/.435 2.50 09 or 10 SQ. KEY x LG. (SAE-E) (100,8/99,1) (11,10/11.05) (63,5)

Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA 23 HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps P24-P30 M, F Dimensions GOLD CUP® Series - Open & Closed Circuits

3.82 (97,0) .88 1.91 (22,3) (48,5) L1 1.50 3/4-10UNC x DEEP L2 8-PLACES (38,1)

10.92 C 1.75 (277,5) "D1" SAE-20 STR. THD. (44,4) CASE DRAIN

SYSTEM PORT A (FAR SIDE) 7.31 6.18 SYSTEM PORT B (NEAR SIDE) 2.00 6000 PSI (185,7) (157,0) SAE- DIA. (50,8) (414 bar) 4-BOLT FLG. CONN B

BG 6.44 6.18 (163,6) (157,0) 6.84 K (173,7) 7.31 (185,7)

"D2" SAE-20 STR. THD. C 1.25 1.25 CASE DRAIN REAR ADAPTER (31,7) (31,8)

7.86 (199,6) 6.44 (163,6)

PUMP L1 L2

7.86 6.44 (199,6) (163,6) P24M 23.33 18.09 PUMP(SHOWN)L1 L2 (592,6) (459,4) P24M 23.33 18.09 OVERHUNG SUPPORT POINT (SHOWN) (592,6) (459,4) 1.25 24.33 19.09 7/8"-9 UNC x DEEP (31,8) P30M24.33 19.09 P30M (618,0) (484,8) P*M (618,0) (484,8)

3.82 (97,0) .88 1.91 1.50 (22,3) (48,5) 3/4-10 UNC x DEEP MOTOR P*F (38,1) L1 L2 8-PLACES MOTOR P24F 21.61 20.46 L1 L2 (SHOWN) (548,8) (519,6) 1.75 20.46 P24F22.61 21.46 21.61 (44,4) P30F (SHOWN)(574,2) (545,0) (548,8) (519,6) SYSTEM PORTS A & B SAE- 2.00 6000 PSI DIA. 22.61 21.46 (50,8) (414 bar) P30F 4-BOLT FLG. CONN (574,2) (545,0) L1 L2 7.86 7.86 (199,6) (199,6) C 10.92 (277,5) "D1" SAE-20 STR. THD. 4.38 4.38 ALTERNATE CASE DRAIN (111,2) (111,2)

7.31 (185,7) B A 6.18 (157,0)

6.18 (157,0) 5.52 6.81 (140.1) (173,0) "M*F" ONLY "M*G" ONLY 7.31 SHOWN IN PHANTOM SHOWN (185,7)

CASE DRAIN "D2" SAE-20 STR. THD. "D" SAE-16 STR. THD. C ALTERNATE CASE DRAIN NOTE: See page 32 for shaft information.

Parker Hannifin Corporation Hydraulic Pump Division 24 Marysville, Ohio USA HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps P24-P30 P Dimensions (Less Controls) GOLD CUP® Series - Open & Closed Circuits

L3 "D1" SAE-20 STR. THD. CASE DRAIN

TABLE 10 PUMP L2L1 L7L4L3 6.44 (163,6) P24P 23.70 18.08 16.34 18.80 (SHOWN) (602,1) (459,4) (414,9) (477,4) 8.14 (206,7) 19.08 P30P 24.70 17.34 19.80 (627,5) (484,7) (440,3) (502,8) 1.66 (42,2)

3.82 6.44 (97,0) (163,6) .88 1.91 (22,3) (48,5) 1.50 3/4-10UNC x DEEP (38,1) 8-PLACES

1.75 "H1" SAE-12 STR THD (44,4) PUMP SERVO & REPLEN. SUPPLY 1.25 INLET FROM EXTERNAL FILTER (31,7)

L1 SYSTEM PORT A (FAR SIDE) SYSTEM PORT B (NEAR SIDE) 2.00 6000 PSI L2 SAE- DIA. C 10.92 (50,8) (414 bar) (277,5) 4-BOLT FLG. CONN

7.31 6.08

T

(154,4) P

(185,7) O K

6.18 (157,0)

B A

6.18 3.26 (82,9) K

(157,0) 4.75 (120,7) G

7.31 (185,7)

"G" SAE-12 STR THD AUX. PUMP (SERVO & REPLEN.) 45˚ L7 OUTLET TO EXTERNAL FILTER C "D2" SAE-20 STR. THD. 1.82 (46,2) CASE DRAIN 7.15 7.15 L4 (181,6) (181,6)

"K" SAE-32 STR THD OPTIONAL-REPLEN. PUMP SUPPLY INLET

1.06 1/2 -13UNC x DEEP 4-PLACES (26,9)

1.53 (38,9) 3.06 (77,7)

2.00 3000 PSI SAE- DIA. (50,8) (207 bar) 4-BOLT FLG. CONN AUX. PUMP (SERVO & REPLEN.) SUPPLY INLET

"C" .84 (21,3)

1.68 P*P (42,7) NOTE: See page 32 for shaft information. See appropriate controls mounting starting on page 34.

Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA 25 HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps P24-P30 X Dimensions (Less Controls) GOLD CUP® Series - Open & Closed Circuits

L3 "D1" SAE-20 STR. THD. CASE DRAIN REAR ADAPTER

TABLE 11 PUMP L1 L2 L7L4L3 6.44 (163,6) P24X 22.83 18.08 16.34 18.80 (414,9) (477,4) (SHOWN) (579,9) (459,4) 8.14 (206,7) 19.08 P30X 23.83 17.34 19.80 (605,3) (484,7) (440,3) (502,8) 1.66 (42,2)

3.82 6.44 (97,0) (163,6) .88 1.91 (22,3) (48,5) 1.50 3/4-10UNC x DEEP 8-PLACES (38,1)

1.75 "H1" SAE-12 STR THD (44,4) PUMP SERVO & REPLEN. SUPPLY 1.25 INLET FROM EXTERNAL FILTER (31,7)

L1 SYSTEM PORT A (FAR SIDE) SYSTEM PORT B (NEAR SIDE) 2.00 6000 PSI L2 SAE- DIA. C 10.92 (50,8) (414 bar) (277,5) 4-BOLT FLG. CONN

7.31 6.08 (185,7) (154,4) G 6.18 (157,0)

B A

6.18 (157,0) 4.75 (120,7) OK P T 7.31 (185,7)

7.15 7.15 L7 (181,6) (181,6) C "D2" SAE-20 STR. THD. CASE DRAIN L4

1.06 1/2 -13UNC x DEEP 4-PLACES (26,9)

1.53 (38,9) 3.06 (77,7)

2.00 3000 PSI SAE- DIA. (50,8) (207 bar) 4-BOLT FLG. CONN AUX. PUMP (SERVO & REPLEN.) SUPPLY INLET

"C" .84 (21,3)

1.68 P*X (42,7) NOTE: See page 32 for shaft information. See pages 45-53 for rear drive information. See appropriate controls mounting starting on page 34.

Parker Hannifin Corporation Hydraulic Pump Division 26 Marysville, Ohio USA HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps P24-P30 S Dimensions (Less Controls) GOLD CUP® Series - Open & Closed Circuits

L3 "D1" SAE-20 STR. THD. CASE DRAIN REAR ADAPTER

6.44 (163,6)

1.66 (42,2)

3.82 6.44 (97,0) (163,6) .88 1.91 (22,3) (48,5) 1.50 3/4-10UNC x DEEP 8-PLACES (38,1)

1.75 "H1" SAE-12 STR THD (44,4) PUMP SERVO & REPLEN. SUPPLY 1.25 INLET FROM EXTERNAL FILTER (31,7)

L1 SYSTEM PORT A (FAR SIDE) SYSTEM PORT B (NEAR SIDE) 2.00 6000 PSI L2 SAE- DIA. C 10.92 (50,8) (414 bar) (277,5) 4-BOLT FLG. CONN

7.31 6.08 (185,7) (154,4) G 6.18 (157,0)

B A

6.18 (157,0)

OK P T 7.31 (185,7)

9.89 L7 (251,3) C "D2" SAE-20 STR. THD. CASE DRAIN 7.15 7.15 (181,6) (181,6)

TABLE 9 PUMP L1 L2 L7L3 P24S 22.83 18.09 16.34 (SHOWN) (579,9) (459,4) (414,9) 8.14 (206,7) 19.09 P30S 23.83 17.34 (605,3) (484,8) (440,3)

"D3" DRAIN CONNECTION SAE-16 STR. THD. NOTE: See page 32 for shaft information. P*S See pages 45-53 for rear drive information. See appropriate controls mounting starting on page 34.

Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA 27 HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps P24-P30 R, L Dimensions (Less Controls) GOLD CUP® Series - Open & Closed Circuits

L3 REAR ADAPTER "D1" SAE-20 STR. THD. CASE DRAIN

TABLE 12 PUMP L2L1 L7L3 6.44 (163,6) P24 23.33 18.08 16.34 (SHOWN) (592,6) (459,4) (414,9) 8.14 (206,7) 24.33 19.08 P30 17.34 (618,0) (484,7) (440,3) 1.66 (42,2)

3.82 6.44 (97,0) (163,6) .88 1.91 (22,3) (48,5) 1.50 3/4-10UNC x DEEP 8-PLACES (38,1)

1.75 "H1" SAE-12 STR THD (44,4) PUMP SERVO & REPLEN. SUPPLY 1.25 INLET FROM EXTERNAL FILTER (31,7)

L1 SYSTEM PORT A (FAR SIDE) SYSTEM PORT B (NEAR SIDE) 2.00 6000 PSI L2 SAE- DIA. 10.92 (50,8) (414 bar) (277,5) 4-BOLT FLG. CONN

7.31 6.08 (185,7) (154,4)

6.18 (157,0) B

B A BG 6.44 6.18 (163,6) (157,0) 9.89 K (251,3) "P*L" ONLY 7.31 SHOWN (185,7) 7.72 (196,2) "P*R" ONLY SHOWN IN PHANTOM

L7

"D2" SAE-20 STR. THD. CASE DRAIN 7.15 7.15 (181,6) (181,6) 1.25 (31,8)

OPTIONAL "K" SAE-16 STR THD REPLEN. SUPPLY INLET

OVERHUNG SUPPORT POINT 1.25 7/8"-9 UNC x DEEP (31,8)

NOTE: See page 32 for shaft information. P*R & P*L See pages 45-54 for rear drive information. See appropriate controls mounting starting on page 34.

Parker Hannifin Corporation Hydraulic Pump Division 28 Marysville, Ohio USA HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps M24-M30 H, V, F, G Dimensions (Less Controls) GOLD CUP® Series - Open & Closed Circuits

3.82 (97,0) .88 1.91 1.50 (22,3) (48,5) 3/4-10 UNC x DEEP 8-PLACES (38,1) TABLE 17 MOTOR TABLE 17 1.75 L1 L2 L7L3 M*H & M*V (44,4) MOTOR L1 M24L2 21.61L7L3 20.46 17.80 (452,0) M24 21.61 (SHOWN)20.46 17.80 (548,8) (519,6) 8.14 (SHOWN) (548,8) (519,6) (452,0) SYSTEM PORTS A & B 8.14 (206,7) SAE- 2.00 6000 PSI 22.61(206,7) 21.46 18.80 DIA. 22.61 M3021.46 18.80 (50,8) (414 bar) M30 (574,2) (545,0) (477,4) (574,2) (545,0) (477,4) 4-BOLT FLG. CONN L1 L2 7.15 7.15 (181,6) (181,6) 10.92 (277,5) "D1" SAE-20 STR. THD. 4.38 4.38 ALTERNATE CASE DRAIN (111,2) (111,2)

7.31 (185,7) B A 6.18 (157,0)

2.31 6.18 (58,7) (157,0) 5.45 6.81 (138,4) (173,0) "M*V" ONLY "M*H" ONLY 7.31 SHOWN IN PHANTOM SHOWN (185,7)

CASE DRAIN L7 "D2" SAE-20 STR. THD. "D" SAE-16 STR. THD. ALTERNATE CASE DRAIN CONTROL PRESSURE INLET "H1" SAE-4 STR THD (NEAR SIDE) "H2" SAE-4 STR THD (FAR SIDE) L3

3.82 (97,0) .88 1.91 1.50 (22,3) (48,5) 3/4-10 UNC x DEEP (38,1) 8-PLACES MOTOR L2L1 1.75 M24 21.61 20.46 M*F & M*G (44,4) MOTOR L1 L2(SHOWN) (548,8) (519,6) M24 21.61 20.46 (SHOWN) (548,8) (519,6) 22.61 21.46 SYSTEM PORTS A & B M30 SAE- 2.00 6000 PSI (545,0) DIA. 22.61 21.46 (574,2) (50,8) (414 bar) M30 (574,2) (545,0) 4-BOLT FLG. CONN L1 L2 7.86 7.86 (199,6) (199,6) 10.92 (277,5) "D1" SAE-20 STR. THD. 4.38 4.38 ALTERNATE CASE DRAIN (111,2) (111,2)

7.31 (185,7) B A 6.18 (157,0)

6.18 (157,0) 5.52 6.81 (140.1) (173,0) "M*F" ONLY "M*G" ONLY 7.31 SHOWN IN PHANTOM SHOWN (185,7)

CASE DRAIN "D2" SAE-20 STR. THD. "D" SAE-16 STR. THD. ALTERNATE CASE DRAIN NOTE: See page 32 for shaft information. See appropriate controls mounting starting on page 34.

Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA 29 HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps M24-M30 M, N Dimensions GOLD CUP® Series - Open & Closed Circuits

M*M & M*N PUMP L1 L2 M24 23.33 18.09 (SHOWN) (592,6) (459,4) 1.50 3/4-10UNC x DEEP 24.33 19.09 8-PLACES (38,1) M30 (618,0) (484,8) 3.82 (97,0) .88 1.91 (22,3) L1 (48,5) L2

10.92 1.75 (277,5) "D1" SAE-20 STR. THD. (44,4) CASE DRAIN

SYSTEM PORT A (FAR SIDE) 7.31 6.18 SYSTEM PORT B (NEAR SIDE) 2.00 6000 PSI (185,7) (157,0) SAE- DIA. (50,8) (414 bar) 4-BOLT FLG. CONN B

BG 6.44 6.18 (163,6) (157,0) 6.84 K (173,7) "M*M" ONLY 7.31 SHOWN IN PHANTOM (185,7) 8.13 (206,5) "M*N" ONLY SHOWN

"D2" SAE-20 STR. THD. 1.25 1.25 CASE DRAIN REAR ADAPTER (31,7) (31,8)

7.86 (199,6) 6.44 (163,6)

7.86 6.44 (199,6) (163,6)

OVERHUNG SUPPORT POINT 1.25 7/8"-9 UNC x DEEP (31,8)

NOTE: See page 32 for shaft information. See pages 45-54 for rear drive information.

Parker Hannifin Corporation Hydraulic Pump Division 30 Marysville, Ohio USA HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps M24-M30 R, L Dimensions GOLD CUP® Series - Open & Closed Circuits

TABLE 18 PUMP M*R & M*L L1 L2 L7 "H1" SAE-6 STR THD (NEAR SIDE) "H2" SAE-6 STR THD (FAR SIDE) M24 23.33 18.09 CONTROL PRESSURE INLET (SHOWN) (592,6) (459,4) 8.14 1.50 (206,7) 3/4-10UNC x DEEP 24.33 19.09 8-PLACES (38,1) M30 (618,0) (484,8) 3.82 "D1" SAE-20 STR. THD. (97,0) CASE DRAIN .88 1.91 (22,3) L1 (48,5) L2

10.92 2.00 (50,7) 1.75 (277,5) (44,4)

SYSTEM PORT A (FAR SIDE) 7.31 6.18 SYSTEM PORT B (NEAR SIDE) 2.00 6000 PSI (185,7) (157,0) SAE- DIA. (50,8) (414 bar) 4-BOLT FLG. CONN B

BG 6.44 6.18 (163,6) (157,0) 6.84 K (173,7) "M*R" ONLY 7.31 SHOWN IN PHANTOM (185,7) 8.13 (206,5) "M*L" ONLY SHOWN

L7 "D2" SAE-20 STR. THD. 1.25 1.25 CASE DRAIN REAR ADAPTER (31,7) (31,8)

7.15 (181,6) 6.44 (163,6)

7.15 6.44 (181,6) (163,6)

OVERHUNG SUPPORT POINT 1.25 7/8"-9 UNC x DEEP (31,8)

NOTE: See page 32 for shaft information. See pages 45-54 for rear drive information. See appropriate controls mounting starting on page 34.

Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA 31 HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps For 24-30 Pumps & Motors GOLD CUP® Series - Open & Closed Circuits

M*F, M*G, M*H, M*V, P*S, P*X, P*P & P*F M*R, M*L, M*M, M*N, P*L & P*R

SAE 177-4 SAE F 1.06 3.47 3.47 DIA. THRU 3.41 3.41 (26,9) 88,1 88,1 S1 2.00 DIA. S'FACE (FAR SIDE) 86,6 86,6 (50,8) 4 PLACES .61 (15,5) .25 (6,2)

1.75 SPLINE LENGTH 2.12 SPLINE LENGTH SEE NOTE 1 (44,4) (53,8) SEE NOTE 2 S3

1.9994 DIA. 50,80 50,78 9.75 2.75 DIA. (247,6) 7.000 (69,8) SQ. 6.998 DIA. 2.218 177,80 2.212 4.87 177,75 56,34 (123,7) 56,18 TYP. .12 .32 x 45˚ (8,1) (3,0) .12 .06 x 45˚ x 45˚ (3,0) (1,5) SAE 177-4 ("F" 4-BOLT) 1.00 (M16 x 2) METRIC THREAD x DEEP SAE 177-4 SAE("F" 50-4 4-BOLT) SAE 177-4 ("F" 4-BOLT) (25,4) ("F"SAE SPLINE) 50-4 SAE 50-1 ("F" SPLINE) ("F" KEYED) NOTES: SHAFT DEGIGNATIONSHAFT DEGIGNATIONSAE INVOLUTE SPLINE DATA J498-B 1969 SHAFT DEGIGNATION PUMP MODEL CODE SAE INVOLUTE SPLINE DATA J498-B 1969PUMP MODEL CODE SHAFT 1. SPLINE LENGTH AND NECK ONLY FOR: PUMP MODELFLAT ROOTCODE SIDE FIT EXTERNAL CLASS-1 S1 S3 3.47/3.41 .500/.498 2.25 M*F, M*G, M*H, M*V, P*S, P*X, P*P & P*F 8/16 PITCH SAE 50-1 SQ. KEY x LG. FLAT ROOT SIDE FIT EXTERNAL CLASS-102 or 07 (SAE-F) (88,1/86,6) (12,70/12.65) (57,1) 2. SPLINE LENGTH ONLY FOR: 03 or 08 30˚ PRESSURE ANGLE 15 TEETH 8/16 PITCH SAE 50-1 LONG 5.35/5.29 .500/.498 4.13 M*R, M*L, M*M, M*N, P*L & P*R 09 or 10 SQ. KEY x LG. 03 or 1.9710-1.9660/08 (50,063-49,936)30˚ PRESSURE MAJOR DIA. ANGLE (SAE-F) (135,9/134,4) (12,70/12.65) (104,9) 15 TEETH 1.9710-1.9660/ (50,063-49,936) MAJOR DIA.

SHAFT DEGIGNATION PUMP MODEL CODE SHAFT S1 S3 3.47/3.41 .500/.498 2.25 SAE 50-1 SQ. KEY x LG. 02 or 07 (SAE-F) (88,1/86,6) (12,70/12.65) (57,1) SAE 50-1 LONG 5.35/5.29 .500/.498 4.13 09 or 10 SQ. KEY x LG. (SAE-F) (135,9/134,4) (12,70/12.65) (104,9)

Parker Hannifin Corporation Hydraulic Pump Division 32 Marysville, Ohio USA HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps GOLD CUP® Valve Block GOLD CUP® Series - Open & Closed Circuits

VB INDIVIDUAL ("B" SIDE) COMPENSATOR VENT CONN. "V" COMMON COMPENSATOR VENT CONN. SAE-4 STR.THD. SAE-4 STR. THD.

V

VA INDIVIDUAL ("A" SIDE) COMPENSATOR VENT CONN. SAE-4 STR. THD.

KG REPLENISHING PRESS. GAGE CONN. SAE-6 STR. THD.

ACCESS PORT PILOT RELIEF VALVE SAE-3 STR.THD. COMPENSATOR ADJUSTMENT (UNDER PLUG) 2000 PSI PER TURN 150 PSI PER TURN

Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA 33 HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps Pump Primary Controls GOLD CUP® Series - Open & Closed Circuits

-B- CONTROL MTG. POSITION -A- CONTROL MTG. POSITION CONTROL PUMP ROTARY SERVO PORT CONTROL PUMP ROTARY SERVO PORT OPTION FIG. ROT. INPUT SHAFT ROTATION "A" OPTION FIG. ROT. INPUT SHAFT ROTATION "A"

1 CW CCW INLET 2 CW CW INLET "10*" "10*" 1 CCW CW INLET 2 CCW CCW INLET

SEE ROTARY SERVO SEE ROTARY SERVO SHAFT DETAIL SHAFT DETAIL L7 L7

SEE TABLES 1-18 SEE TABLES 1-18

O

F F

F O F 1.40 1.40 (35,6) (35,6) SCREW ADJ. (CW ROT.) MIN. VOLUME STOP (CW ROT.) MIN. VOLUME STOP (CCW ROT.) MIN. VOLUME STOP (CW ROT.) SCREW ADJ. (CCW ROT.) SCREW ADJ. (CCW ROT.) .45 (11,4) FIGURE -2 .25 FIGURE -1 1/4-20UNC TAP x DEEP .32 (6,4) (8,1)

ROTARY SERVO SHAFT DETAIL

.513 SEE ROTARY SERVO .508 SEE ROTARY SERVO MAJOR DIA. KNURL SHAFT DETAIL SHAFT DETAIL 13.03 (32 TEETH PER INCH) ( 12.90 ) .45 .45 (11,5) L7 L7 (11,5) SEE TABLES 1-18 SEE TABLES 1-18

"Y" O "X"

F F 2.50 (63,5)

2.50

(63,5) F O F "X" "Y"

1.40 MIN. VOLUME STOP (CCW ROT.) 1.40 1.00 1.00 (35,6) MAX. VOLUME STOP (CW ROT.) (35,6) 1.00 (25,4) (25,4) 1.00 MIN. VOLUME STOP (CCW ROT.) (25,4) (25,4) MAX. VOLUME STOP (CCW ROT.) MAX. VOLUME STOP (CW ROT.) MIN. VOLUME STOP (CW ROT.) FIGURE -1 FIGURE -2 -B- CONTROL MTG. POSITION -A- CONTROL MTG. POSITION CONTROL SPRING OFF-SET TO MIN, VOLUME CONTROL SPRING OFF-SET TO MIN, VOLUME PRESSURE SIGNAL TO: PRESSURE SIGNAL TO: CONTROL PUMP PORT CONTROL PUMP PORT FIG. FIG. OPTION ROT. 1/8-27 N.P.T.F. 1/8-27 N.P.T.F. "A" OPTION ROT. 1/8-27 N.P.T.F. 1/8-27 N.P.T.F. "A" PORT "X" PORT "Y" PORT "X" PORT "Y" 1 CW MAX. VOL. MIN. VOL. INLET 2 CW MIN. VOL. MAX. VOL. INLET "2A*" "2A*" 1 CCW MIN. VOL. MAX. VOL. INLET 2 CCW MAX. VOL. MIN. VOL. INLET

Parker Hannifin Corporation Hydraulic Pump Division 34 Marysville, Ohio USA HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps Pump Primary Controls GOLD CUP® Series - Open & Closed Circuits

-B- CONTROL MTG. POSITION -A- CONTROL MTG. POSITION CONTROL SPRING OFF-SET TO MIN, VOLUME CONTROL SPRING OFF-SET TO MIN, VOLUME PRESSURE SIGNAL ROTARY SERVO PRESSURE SIGNAL ROTARY SERVO CONTROL PORT PORT CONTROL PORT PORT FIG. PUMP TO SAE-4 INPUT SHAFT FIG. PUMP TO SAE-4 INPUT SHAFT OPTION ROT. OPTION ROT. STR. THD. PORT: ROTATION "A" "B" STR. THD. PORT: ROTATION "A" "B"

1 CW "X" CCW INLET OUTLET 2 CW "Y" CW INLET OUTLET "2H*" 1 CCW "Y" CW INLET OUTLET "2H*" 2 CCW "X" CCW INLET OUTLET 1 CW "Y" CW OUTLET INLET 2 CW "X" CCW OUTLET INLET 1 CCW "X" CCW OUTLET INLET 2 CCW "Y" CW OUTLET INLET

SEE ROTARY SERVO SEE ROTARY SERVO SHAFT DETAIL SHAFT DETAIL .47 (12,0) L7 L7

SEE TABLES 1-18 SEE TABLES 1-18

"Y" O "X" F

2.47 F (62,7)

2.47

F O F (62,7) "X" "Y"

1.40 MAX. VOLUME STOP 1.40 1.00 1.00 (35,6) (35,6) 1.00 (25,4) (25,4) 1.00 (25,4) (25,4) MAX. VOLUME STOP TRIMMER ADJ. MAX. VOLUME STOP .45 (11,4) .25 1/4-20UNC TAP x DEEP .32 FIGURE -1 (6,4) (8,1) FIGURE -2

ROTARY SERVO SHAFT DETAIL

SEE ROTARY SERVO .513 SEE ROTARY SERVO .508 SHAFT DETAIL MAJOR DIA. KNURL SHAFT DETAIL 13.03 (32 TEETH PER INCH) ( 12.90 ) TRIMMER ADJ. L7 L7

SEE TABLES 1-18 SEE TABLES 1-18

O F F

F O F

1.40 MAX. VOLUME STOP 1.40 (35,6) TRIMMER ADJ. MAX. VOLUME STOP (35,6) MAX. VOLUME STOP FIGURE -1 FIGURE -2 -B- CONTROL MTG. POSITION -A- CONTROL MTG. POSITION CONTROL SPRING OFF-SET TO MIN, VOLUME CONTROL SPRING OFF-SET TO MIN, VOLUME ROTARY SERVO ROTARY SERVO CONTROL PORT PORT CONTROL PORT PORT FIG. PUMP INPUT SHAFT FIG. PUMP INPUT SHAFT OPTION ROT. OPTION ROT. ROTATION "A" "B" ROTATION "A" "B"

1 CW CCW INLET OUTLET 2 CW CW INLET OUTLET "4A*" 1 CCW CW INLET OUTLET "4A*" 2 CCW CCW INLET OUTLET 1 CW CW OUTLET INLET 2 CW CCW OUTLET INLET 1 CCW CCW OUTLET INLET 2 CCW CW OUTLET INLET

Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA 35 HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps Pump Primary Controls GOLD CUP® Series - Open & Closed Circuits

-B- CONTROL MTG. POSITION -A- CONTROL MTG. POSITION CONTROL SPRING OFF-SET TO MIN, VOLUME CONTROL SPRING OFF-SET TO MIN, VOLUME ROTARY SERVO ROTARY SERVO CONTROL PORT PORT CONTROL PORT PORT FIG. PUMP INPUT SHAFT FIG. PUMP INPUT SHAFT OPTION ROT. OPTION ROT. ROTATION "A" "B" ROTATION "A" "B"

1 CW CCW INLET OUTLET 2 CW CW INLET OUTLET "5A*" 1 CCW CW INLET OUTLET "5A*" 2 CCW CCW INLET OUTLET 1 CW CW OUTLET INLET 2 CW CCW OUTLET INLET 1 CCW CCW OUTLET INLET 2 CCW CW OUTLET INLET

SEE ROTARY SERVO SHAFT DETAIL SEE ROTARY SERVO SHAFT DETAIL NULL ADJ. 4.10 TRIMMER ADJ. MAX. VOLUME STOP SCREW (104,0) L7 SEE TABLES 1-18 L7 4.30 SEE TABLES 1-18 (109,3)

MARYSVILLE , OHIO U.S.A.

ASS'Y NO.

SERIAL NO.

ELEC. RATINGS: L = 1.5 mh MAX. I = 330 ma MAX. V = 10.56 VOLTS D.C. MAX. 5.02 HAZARDOUS LOCATION SUITABILITY: 1. NONINCENDIVE CLASS I, DIVISION 2, GROUPS A, B, C, AND D. 2. CLASS II, DIVISION 2, GROUPS F AND G. WARNING- DO NOT DISCONNECT WHILE CIRCUIT IS LIVE UNLESS LOCATION IS KNOWN TO BE (127,6) NONHAZARDOUS. B-8241 9 - 330 0 3 3 9- 1 4

2 8

B-

NONHAZARDOUS.

LOCATION IS KNOWN TO BE TO KNOWN IS LOCATION

WHILE CIRCUIT IS LIVE UNLESS LIVE IS CIRCUIT WHILE

WARNING- DO NOT DISCONNECT NOT DO WARNING-

2. CLASS II, DIVISION 2, GROUPS F AND G. AND F GROUPS 2, DIVISION II, CLASS 2.

GROUPS A, B, C, AND D. AND C, B, A, GROUPS

1. NONINCENDIVE CLASS I, DIVISION 2, DIVISION I, CLASS NONINCENDIVE 1. 5.02

HAZARDOUS LOCATION SUITABILITY: LOCATION HAZARDOUS

V = 10.56 VOLTS D.C. MAX. D.C. VOLTS 10.56 = V I = 330 ma MAX. ma 330 = I

L = 1.5 mh MAX. mh 1.5 = L ELEC. RATINGS: ELEC.

SERIAL NO. SERIAL

ASS'Y NO. ASS'Y (127,6) MARYSVILLE , OHIO U.S.A. OHIO , MARYSVILLE

4.30 MAX. VOLUME STOP (109,3) TRIMMER ADJ. .56 4.10 NULL ADJ. MAX. VOLUME STOP SCREW FIGURE -1 (14,2) (104,0) .49 .3760 (12,5) FIGURE -2 .3755 DIA. INPUT (9,550) A B CCW (9,538) + 19˚ CCW CURRENT AT FULL DISPL. (MECH. STOP) .31 350 MA. NOM. DIA. WITH .20 WIDE FLAT COIL RESISTANCE (7,9) 25 NOM. A O A+ POLARITY WITH ELECTRICAL POLARITY AS SHOWN O INPUT SHAFT WILL ROTATE CCW CW 19˚ CW .15 ELECTRICAL INPUT (3,8) .390 (MECH. ECT. RECEPTACLE CONN. 5/8-24UNEF x MAX. STOP) (9,91) ATING CONN. HALF, MS3106E-10SL-4S) MANUAL OVERRIDE DETAIL TO OPERATE, DISCONNECT OIL SUPPLY TO STROKER SEE ROTARY SERVO SEE ROTARY SERVO 50in/lbs SHAFT DETAIL SHAFT DETAIL DO NOT EXCEED TORQUE. L7 "Z" BRAKE ACTUATOR PORT (6 N.m) SAE-6 STR. THD. 4.30 NULL ADJ. 4.10 TRIMMER ADJ. MAX. VOLUME STOP (109,3) SCREW (104,0) .59 (15,1) L7 .45 (11,4)

L8 2.47 (62,7)

2.47 (62,7)

MAX. VOLUME STOP .45 TRIMMER ADJ. (11,4) .59 NULL ADJ. 4.30 "Z" BRAKE ACTUATOR PORT 4.10 MAX. VOLUME STOP (15,1) SCREW (109,3) SAE-6 STR. THD. (104,0) FIGURE -1 FIGURE -2

-B- CONTROL MTG. POSITION SERIES SIZE L7 L8 -A- CONTROL MTG. POSITION 6, 7 & 8 5.15 CONTROL SPRING OFF-SET TO MIN, VOLUME CONTROL SPRING OFF-SET TO MIN, VOLUME (SAE 127-2) (130,9) 6.20 ROTARY SERVO 6, 7 & 8 6.49 (157,4) ROTARY SERVO CONTROL PORT PORT CONTROL PORT PORT FIG. PUMP INPUT SHAFT FIG. PUMP INPUT SHAFT OPTION ROT. (SAE 152-4) (164,8) OPTION ROT. ROTATION "A" "B" ROTATION "A" "B" 6.38 6.77 11 & 14 1 CW CCW INLET OUTLET (162,0) (171,9) 2 CW CW INLET OUTLET 8.14 8.64 1 CCW CW INLET OUTLET 24 & 30 2 CCW CCW INLET OUTLET "5C*" (206,7) (219,4) "5C*" 1 CW CW OUTLET INLET 2 CW CCW OUTLET INLET 1 CCW CCW OUTLET INLET 2 CCW CW OUTLET INLET

Parker Hannifin Corporation Hydraulic Pump Division 36 Marysville, Ohio USA HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps Pump Primary Controls GOLD CUP® Series - Open & Closed Circuits

-B- CONTROL MTG. POSITION SERIES SIZE L7 L8 L9 -A- CONTROL MTG. POSITION 6, 7 & 8 5.15 PORT PORT IINDICATOR PORT PORT CONTROL PUMP IINDICATOR (SAE 127-2) (130,9) CONTROL PUMP FIG. 9.43 5.63 OPTION FIG. OPTION ROT. ROTATION "A" "B" ROT. ROTATION "A" "B" 6, 7 & 8 6.49 (239,6) (143,1) 1 CW CCW INLET OUTLET (SAE 152-4) (164,8) 2 CW CW INLET OUTLET 1 CCW CW INLET OUTLET 6.38 10.00 6.20 2 CCW CCW INLET OUTLET "7D*" 11 & 14 (162,0) (254,1) (157,5) "7D*" INLET 1 CW CW OUTLET INLET 2 CW CCW OUTLET 8.14 11.87 8.07 INLET 1 CCW CCW OUTLET INLET 24 & 30 (206,7) (301,5) (205,0) 2 CCW CW OUTLET

PT SERVOVALVE INLET SERVOVALVE INLET A- A+ SAE-8 STR. THD. SAE-8 STR. THD. B+ B- 2 1 "B" OVERRIDE "A" OVERRIDE L7 L7 TUBE B A TUBE SERVOVALVE DIAGRAM

L9 L8

O F

SERVOVALVE F PORT PORT PUMP COIL CAM SERVOVALVE ROT. POLARITY PORTING "A" "B"PORT PORT PUMP COIL CW ABOVECAMA+ or B- P---2 OUTLET INLET PORTING "A" "B" MATING CONN. F O F ROT. POLARITY #721-30004

CW BELOW A- or B+ P---1 INLET OUTLET CW ABOVE A+ or B- P---2 OUTLET INLET -

CCW BELOW A+ or B- P---2 OUTLET INLET DD + 5MA/DC/NOM. CCWCW ABOVEBELOWA- or B+A- or P---1B+ P---1INLET OUTLETINLET OUTLET FIGURE -2

FIGURE -1 C C CCW BELOW A+ or B- P---2 OUTLET INLET -

BB CCW ABOVE A- or B+ P---1 INLET OUTLET + 5MA/DC/NOM. AA

SERVOVALVE DIAGRAM

-B- CONTROL MTG. POSITION SERIES SIZE L7 L8 L10L9 -A- CONTROL MTG. POSITION 6, 7 & 8 5.15 VOL. INDICATOR (SAE 127-2) (130,9) VOL. INDICATOR CONTROL PUMP VALVE COMMAND PORT PORT 12.70 5.63 CONTROL PUMP VALVE COMMAND PORT PORT FIG. SHAFT ROT. FIG. SHAFT ROT. OPTION ROT. D TO E 6, 7 & 8 6.49 (322,6) (143,1) OPTION ROT. D TO E (SHOWN) "A" "B" (SHOWN) "A" "B" (SAE 152-4) (164,8) 7.66 1 CW 0...-10V INLET OUTLET (194,6) 2 CW 0...-10V INLET OUTLET CCW 6.38 14.37 6.20 CW 11 & 14 (162,0) (365,0) (157,5) 1 CCW 0...-10V CW INLET OUTLET 2 CCW 0...-10V CCW INLET OUTLET "7J*" 8.14 14.58 8.07 INLET "7J*" INLET 1 CW 0...+10V CW OUTLET 24 & 30 (206,7) (370,3) (205,0) 2 CW 0...+10V CCW OUTLET 1 CCW 0...+10V CCW OUTLET INLET 2 CCW 0...+10V CW OUTLET INLET

CIRCULAR CONNECTOR-7 PIN, DIN 43563 L10

6 + PE Zero position Command A 0...±10V E F B 0...±20mA PID G 4...20mA D E C D

Diagnostic F spool stroke 0 U 0...±10V C = = L7 L7 + 0 G A B

Supply L9 L8 O F

PE voltage F 22...30V

D1FP ( DF Plus) WIRING SCHEMATIC

F O F

FIGURE -1 FIGURE -2

Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA 37 HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps Pump Primary Controls GOLD CUP® Series - Open & Closed Circuits

-B- CONTROL MTG. POSITION SERIES SIZE L9L8L7 -A- CONTROL MTG. POSITION 6, 7 & 8 5.15 ROTARY SERVO ROTARY SERVO CONTROL PORT PORT (SAE 127-2) (130,9) 9.43 5.63 CONTROL PUMP PORT PORT FIG. PUMP INPUT SHAFT FIG. INPUT SHAFT OPTION ROT. (239,6) (143,1) OPTION ROT. ROTATION "A" "B" 6, 7 & 8 6.49 ROTATION "A" "B" (SAE 152-4) (164,8) 1 CW INLET OUTLET 2 CW CW INLET OUTLET CCW 6.38 10.00 6.20 11 & 14 CCW (162,0) (254,1) (157,5) 2 CCW CCW INLET OUTLET 1 CW INLET OUTLET "7F*" "7F*" 8.14 11.87 8.07 INLET CW INLET 1 CW CW OUTLET 24 & 30 (206,7) (301,5) (205,0) 2 CCW OUTLET INLET 1 CCW CCW OUTLET INLET 2 CCW CW OUTLET

MANUAL SERVOVALVE SHUT-OFF SHOWN IN OPEN POSITION

TP SERVOVALVE INLET A- A+ SAE-8 STR. THD. B+ B- SEE ROTARY SERVO 2 1 SHAFT DETAIL TRIMMER ADJ. SEE ROTARY SERVO SHAFT DETAIL "B" OVERRIDE "A" OVERRIDE L7 L7 TUBE B A TUBE SERVOVALVE DIAGRAM

L9 L8

O F F SERVOVALVE PORT PORT PUMP CAMSERVOVALVECOIL PORT PORT ROT. POLARITY PORTING "A" "B" PUMP CAM COIL CW ABOVE A+PORTING or B- P---2 "A"OUTLET "B"INLET ROT. POLARITY F O F CW BELOW A- or B+ P---1 INLET OUTLET CW ABOVE A+ or B- P---2 OUTLET INLET CCW BELOW A+ or B- P---2 OUTLET INLET 1.40 MAX. VOLUME STOP SERVOVALVE INLET 1.40 CW A- or B+ P---1 INLET OUTLET (35,6) SAE-8 STR. THD. (35,6) BELOW CCW ABOVE A- or B+ P---1 INLET OUTLET TRIMMER ADJ. MAX. VOLUME STOP MAX. VOLUME STOP .45 (11,4) CCW .25 BELOW A+ or B- P---2 OUTLET INLET 1/4-20UNC TAP x DEEP .32 FIGURE -1 (6,4) (8,1) CCW ABOVE A- or B+ P---1 INLET OUTLET FIGURE -2

ROYTARY SERVO SHAFT DETAIL SERIES SIZE L7 L9L8 .513 .508 A B 6, 7 & 8 5.15 MAJOR DIA. KNURL 13.03 (SAE 127-2) (130,9) 10.63 5.63 (32 TEETH PER INCH) ( 12.90 ) A B & (270 1) (143 1)

-B- CONTROL MTG. POSITION SERIES SIZE L7 L8 L10L9 -A- CONTROL MTG. POSITION 6, 7 & 8 5.15 CONTROL INPUT (SAE 127-2) (130,9) CONTROL INPUT CONTROL PUMP VALVE COMMAND PORT PORT 12.70 5.63 CONTROL PUMP VALVE COMMAND PORT PORT FIG. SHAFT ROT. FIG. SHAFT ROT. OPTION ROT. D TO E 6, 7 & 8 6.49 (322,6) (143,1) OPTION ROT. D TO E (SHOWN) "A" "B" (SHOWN) "A" "B" (SAE 152-4) (164,8) 7.66 1 CW 0...-10V INLET OUTLET (194,6) 2 CW 0...-10V INLET OUTLET CCW 6.38 14.37 6.20 CW 11 & 14 (162,0) (365,0) (157,5) 1 CCW 0...-10V CW INLET OUTLET 2 CCW 0...-10V CCW INLET OUTLET "7K*" 8.14 14.58 8.07 INLET "7K*" INLET 1 CW 0...+10V CW OUTLET 24 & 30 (206,7) (370,3) (205,0) 2 CW 0...+10V CCW OUTLET 1 CCW 0...+10V CCW OUTLET INLET 2 CCW 0...+10V CW OUTLET INLET

MANUAL SERVOVALVE SHUT-OFF CIRCULAR CONNECTOR-7 PIN, DIN 43563 SHOWN IN OPEN POSITION L10 6 + PE Zero position Command A 0...±10V E F B 0...±20mA n PID G 4...20mA D E C PID D SEE ROTARY SERVO SHAFT DETAIL Diagnostic F spool stroke 0 U C 0...±10V U TRIMMER ADJ. = = = L7 L7 = + 0 + 0 G G A B A B Supply

PE voltage Supply L9 L8

O F

PE 22...30V voltage F 22...30V WIRING SCHEMATIC D1FP ( DF Plus) WIRING SCHEMATIC

F O F

MAX. VOLUME STOP TRIMMER ADJ. MAX. VOLUME STOP MAX. VOLUME STOP FIGURE -1 FIGURE -2 Parker Hannifin Corporation Hydraulic Pump Division 38 Marysville, Ohio USA HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps Pump Primary Controls GOLD CUP® Series - Open & Closed Circuits

-B- CONTROL MTG. POSITION -A- CONTROL MTG. POSITION CONTROL SPRING OFF-SET TO MIN, VOLUME CONTROL SPRING OFF-SET TO MIN, VOLUME PRESSURE SIGNAL ROTARY SERVO PRESSURE SIGNAL ROTARY SERVO CONTROL PORT PORT CONTROL PORT PORT FIG. PUMP TO SAE-4 INPUT SHAFT FIG. PUMP TO SAE-4 INPUT SHAFT OPTION ROT. OPTION ROT. STR. THD. PORT: ROTATION "A" "B" STR. THD. PORT: ROTATION "A" "B"

1 CW "P1" CCW INLET OUTLET 2 CW "P2" CW INLET OUTLET "8A*" 1 CCW "P2" CW INLET OUTLET "8A*" 2 CCW "P1" CCW INLET OUTLET 1 CW "P2" CW OUTLET INLET 2 CW "P1" CCW OUTLET INLET 1 CCW "P1" CCW OUTLET INLET 2 CCW "P2" CW OUTLET INLET

SEE ROTARY SERVO SEE ROTARY SERVO SHAFT DETAIL SHAFT DETAIL TRIMMER ADJ. LOCKNUT .54 .54 (13,7) L7 L7 (13,7)

SEE TABLES 1-18 SEE TABLES 1-18

O "P2" "P1" F

F 2.47 (62,7)

2.47

(62,7) F O F "P1" "P2"

1.49 MAX. VOLUME STOP 1.00 1.00 1.49 (37,9) 1.00 (25,4) TRIMMER ADJ. (25,4) 1.00 (37,9) (25,4) (25,4) MAX. VOLUME STOP MAX. VOLUME STOP .45 (11,4) .25 1/4-20UNC TAP x DEEP .32 FIGURE -1 (6,4) (8,1) FIGURE -2

ROTARY SERVO SHAFT DETAIL "Z" BRAKE ACTUATOR PORT .513 .508 37 1/2˚ FLARED FITTING MAJOR DIA. KNURL L7 SEE ROTARY SERVO 9/16-18 UNF 13.03 (32 TEETH PER INCH) SEE TABLES 1-18 SEE ROTARY SERVO SHAFT DETAIL ( 12.90 ) SHAFT DETAIL TRIMMER ADJ. LOCKNUT 1.00 .59 (25,4) L7 .54 SEE TABLES 1-18 (15,1) 1.00 .54 (13,7) (25,4) (13,7)

4.39 6.20

O "P2" F "P1" (111,4) F (157,4) 2.47 (62,7)

2.47

(62,7) F O F 4.39 (111,4)

1.49 MAX. VOLUME STOP 1.00 .59 1.49 (37,9) TRIMMER ADJ. 1.00 (25,4) (15,1) (37,9) (25,4) MAX. VOLUME STOP MAX. VOLUME STOP "Z" BRAKE ACTUATOR PORT 37 1/2˚ FLARED FITTING FIGURE -1 9/16-18 UNF FIGURE -2 -B- CONTROL MTG. POSITION -A- CONTROL MTG. POSITION CONTROL SPRING OFF-SET TO MIN, VOLUME CONTROL SPRING OFF-SET TO MIN, VOLUME PRESSURE SIGNAL ROTARY SERVO PRESSURE SIGNAL ROTARY SERVO CONTROL PORT PORT CONTROL PORT PORT FIG. PUMP TO SAE-4 INPUT SHAFT FIG. PUMP TO SAE-4 INPUT SHAFT OPTION ROT. OPTION ROT. STR. THD. PORT: ROTATION "A" "B" STR. THD. PORT: ROTATION "A" "B"

1 CW "P1" CCW INLET OUTLET 2 CW "P2" CW INLET OUTLET "8C*" 1 CCW "P2" CW INLET OUTLET "8C*" 2 CCW "P1" CCW INLET OUTLET 1 CW "P2" CW OUTLET INLET 2 CW "P1" CCW OUTLET INLET

1 CCW "P1" CCW OUTLET INLET 2 CCW "P2" CW OUTLET INLET

Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA 39 HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps Pump Primary Controls GOLD CUP® Series - Open & Closed Circuits

-B- CONTROL MTG. POSITION -A- CONTROL MTG. POSITION MANUAL MANUAL CONTROL ENERGIZE PORT PORT CONTROL ENERGIZE PORT PORT FIG. PUMP OVERRIDE SHAFT FIG. PUMP OVERRIDE SHAFT OPTION ROT. OPTION ROT. SOLENOID ROTATION "A" "B" SOLENOID ROTATION "A" "B"

1 CW "A" CCW INLET OUTLET 2 CW "B" CW INLET OUTLET "9A*" 1 CCW "B" CW INLET OUTLET "9A*" 2 CCW "A" CCW INLET OUTLET 1 CW "B" CW OUTLET INLET 2 CW "A" CCW OUTLET INLET 1 CCW "A" CCW OUTLET INLET 2 CCW "B" CW OUTLET INLET L7 SEE MANUAL OVERRIDE SEE MANUAL OVERRIDE SEE TABLES 1-18 SHAFT DETAIL SHAFT DETAIL TRIMMER ADJ. LOCKNUT SOL. "B" SOL. "A" 3.17 (80,5) L7 2.67 SEE TABLES 1-18 (67,8)

5.12 O (130,1)

5.12 O (130,1) 2.67 MAX. VOLUME STOP (67,8) 3.17 SOL. "B" TRIMMER ADJ. (80,5) SOL. "A" .55 MAX. VOLUME STOP (14,0) MAX. VOLUME STOP .19 HEX RECESS x .12 DEEP (4,8) FIGURE -1 (3,0) FIGURE -2 MANUAL OVERRIDE SHAFT DETAIL "Z" BRAKE ACTUATOR PORT 37 1/2˚ FLARED FITTING L7 2.67 9/16-18 UNF SEE TABLES 1-18 "B"SOL. 3.17 (67,8) TRIMMER ADJ. LOCKNUT .59 SOL. "A" (80,5) L7 .54 SEE TABLES 1-18 (15,1) .54 (13,7) (13,7)

5.12

4.39 6.20 O (130,1) (111,4) (157,4)

5.12 O 4.39 (130,1) (111,4)

MAX. VOLUME STOP .59 2.67 SOL. "B" TRIMMER ADJ. 3.17 (15,1) (67,8) (80,5) SOL. "A" "Z" BRAKE ACTUATOR PORT MAX. VOLUME STOP SEE MANUAL OVERRIDE MAX. VOLUME STOP 37 1/2˚ FLARED FITTING SHAFT DETAIL SEE MANUAL OVERRIDE FIGURE -1 9/16-18 UNF FIGURE -2 SHAFT DETAIL -B- CONTROL MTG. POSITION -A- CONTROL MTG. POSITION MANUAL MANUAL CONTROL ENERGIZE PORT PORT CONTROL ENERGIZE PORT PORT FIG. PUMP OVERRIDE SHAFT FIG. PUMP OVERRIDE SHAFT OPTION ROT. OPTION ROT. SOLENOID ROTATION "A" "B" SOLENOID ROTATION "A" "B"

1 CW "A" CCW INLET OUTLET 2 CW "B" CW INLET OUTLET "9C*" 1 CCW "B" CW INLET OUTLET "9C*" 2 CCW "A" CCW INLET OUTLET 1 CW "B" CW OUTLET INLET 2 CW "A" CCW OUTLET INLET 1 CCW "A" CCW OUTLET INLET 2 CCW "B" CW OUTLET INLET

Parker Hannifin Corporation Hydraulic Pump Division 40 Marysville, Ohio USA HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps Motor Primary Controls GOLD CUP® Series - Open & Closed Circuits

-B- CONTROL MTG. POSITION -A- CONTROL MTG. POSITION CONTROL SPRING OFF-SET TO FULL VOLUME CONTROL SPRING OFF-SET TO FULL VOLUME PRESSURE SIGNAL TO: PRESSURE SIGNAL TO: CONTROL MOTOR PORT CONTROL MOTOR PORT FIG. FIG. OPTION ROT. 1/8-27 N.P.T.F. 1/8-27 N.P.T.F. "A" OPTION ROT. 1/8-27 N.P.T.F. 1/8-27 N.P.T.F. "A" PORT "X" PORT "Y" PORT "X" PORT "Y" 1 CW INLET 2 CW INLET "2A*" REDUCED SPEED FULL SPEED "2A*" FULL SPEED REDUCED SPEED 1 CCW OUTLET 2 CCW OUTLET

.513 SEE ROTARY SERVO .508 SEE ROTARY SERVO MAJOR DIA. KNURL SHAFT DETAIL SHAFT DETAIL 13.03 (32 TEETH PER INCH) ( 12.90 ) .45 .45 (11,5) L7 L7 (11,5) SEE TABLES 1-18 SEE TABLES 1-18

"Y" O "X" F

F 2.50 (63,5)

2.50

F (63,5) O F "X" "Y"

1.40 1.40 1.00 1.00 (35,6) MAX. VOLUME STOP (35,6) 1.00 (25,4) (25,4) 1.00 MIN. VOLUME STOP (25,4) MIN. VOLUME STOP (25,4) MAX. VOLUME STOP

(25,4) (25,4) MAX. VOLUME STOP MIN. VOLUME STOP FIGURE -1 .45 FIGURETRIMMER -2 ADJ. (11,4) FIGURE -1 .25 1/4-20UNC TAP x DEEP .32 (6,4) (8,1) FIGURE -2

ROTARY SERVO SHAFT DETAIL

.513 SEE ROTARY SERVO .508 SEE ROTARY SERVO MAJOR DIA. KNURL SHAFT DETAIL SHAFTSEE ROTARYDETAIL SERVO 13.03 (32 TEETH PER INCH) SHAFT DETAIL ( 12.90 ) .45 SEE ROTARY SERVO .45 SHAFT DETAIL NULL ADJ. 4.10 TRIMMER ADJ. MAX. VOLUME STOP SCREW (104,0) L7 SEE TABLES 1-18 MAX. VOLUME STOP L7 4.30 SEE TABLES 1-18 (109,3)

MARYSVILLE , OHIO U.S.A.

ASS'Y NO.

SERIAL NO.

ELEC. RATINGS: L = 1.5 mh MAX. I = 330 ma MAX. V = 10.56 VOLTS D.C. MAX. 5.02 HAZARDOUS LOCATION SUITABILITY: 1. NONINCENDIVE CLASS I, DIVISION 2, GROUPS A, B, C, AND D. 2. CLASS II, DIVISION 2, GROUPS F AND G. WARNING- DO NOT DISCONNECT WHILE CIRCUIT IS LIVE UNLESS LOCATION IS KNOWN TO BE (127,6) NONHAZARDOUS. B-82419-330 30 -3 419

2

B-8

NONHAZARDOUS.

LOCATION IS KNOWN TO BE TO KNOWN IS LOCATION

WHILE CIRCUIT IS LIVE UNLESS LIVE IS CIRCUIT WHILE

WARNING- DO NOT DISCONNECT NOT DO WARNING-

2. CLASS II, DIVISION 2, GROUPS F AND G. AND F GROUPS 2, DIVISION II, CLASS 2.

GROUPS A, B, C, AND D. AND C, B, A, GROUPS

1. NONINCENDIVE CLASS I, DIVISION 2, DIVISION I, CLASS NONINCENDIVE 1. 5.02

HAZARDOUS LOCATION SUITABILITY: LOCATION HAZARDOUS

V = 10.56 VOLTS D.C. MAX. D.C. VOLTS 10.56 = V I = 330 ma MAX. ma 330 = I

L = 1.5 mh MAX. mh 1.5 = L ELEC. RATINGS: ELEC.

SERIAL NO. SERIAL

ASS'Y NO. ASS'Y (127,6) MARYSVILLE , OHIO U.S.A. OHIO , MARYSVILLE

4.30 (109,3) TRIMMER ADJ. MIN. VOLUME STOP 4.10 NULL ADJ. FIGURE -1 MIN. VOLUME STOP FIGURE -2 (104,0) SCREW

-B- CONTROL MTG. POSITION -A- CONTROL MTG. POSITION CONTROL SPRING OFF-SET TO FULL VOLUME CONTROL SPRING OFF-SET TO FULL VOLUME ROTARY SERVO ROTARY SERVO ROTARY SERVO ROTARY SERVO CONTROL MOTOR PORT PORT CONTROL MOTOR PORT PORT OPTION FIG. ROT. INPUT SHAFT INPUT SHAFT OPTION FIG. ROT. INPUT SHAFT INPUT SHAFT CCW ROTATION CW ROTATION "A" "B" CCW ROTATION CW ROTATION "A" "B" 1 CW INLET OUTLET 2 CW INLET OUTLET "5A*" REDUCED SPEED FULL SPEED "5A*" FULL SPEED REDUCED SPEED 1 CCW OUTLET INLET 2 CCW OUTLET INLET

Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA 41 HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps Motor Primary Controls GOLD CUP® Series - Open & Closed Circuits

-B- CONTROL MTG. POSITION -A- CONTROL MTG. POSITION CONTROL SPRING OFF-SET TO FULL VOLUME CONTROL SPRING OFF-SET TO FULL VOLUME PRESSURE SIGNAL PRESSURE SIGNAL ROTARY SERVO ROTARY SERVO MOTOR TO SAE-4 PORT PORT MOTOR TO SAE-4 PORT PORT CONTROL FIG. CONTROL FIG. OPTION ROT. STR. THD. PORT INPUT SHAFT OPTION ROT. STR. THD. PORT INPUT SHAFT ROTATION "A" "B" ROTATION "A" "B" P2 P1

1 CW CW INLET OUTLET 2 CW CCW INLET OUTLET "8A*" FULL SPEED "8A*" FULL SPEED 1 CCW CW OUTLET INLET 2 CCW CCW OUTLET INLET

SEE ROTARY SERVO SEE ROTARY SERVO SHAFT DETAIL SHAFT DETAIL TRIMMER ADJ. LOCKNUT .54 .54 (13,7) L7 TRIMMER ADJ. LOCKNUT L7

SEE TABLES 1-18 SEE TABLES 1-18 (13,7)

O "P2" "P1" F

F 2.47 (62,7)

2.47

(62,7) F O F "P1" "P2" MIN. VOLUME STOP

1.49 MAX. VOLUME STOP 1.00 1.00 1.49 (37,9) 1.00 (25,4) TRIMMER ADJ. (25,4) 1.00 (37,9) .56 (25,4) (25,4) MAX. VOLUME STOP MIN. VOLUME STOP (14,2) .45 TRIMMER ADJ. (11,4) FIGURE -1 .25 .49 1/4-20UNC TAP x DEEP .3760.32 (6,4) (12,5) 19˚ NULLED AT 0 CURRENT .3755(8,1) FIGURE -2 DIA. (MECH. A B (9,550) STOP) + (9,538) CURRENT AT FULL DISPL. 350 MA. NOM. .31 DIA. WITH COIL RESISTANCE (7,9) 25 NOM. .20 WIDE FLAT 6˚ CW O WITH ELECTRICAL POLARITY AS SHOWN (MECH. INPUT SHAFT WILL ROTATE CW STOP) .15 A O A+ ELECTRICAL INPUT (3,8) POLARITY .390 (ELECT. RECEPTACLE CONN. 5/8-24UNEF x MAX. (9,91) MATING CONN. HALF, MS3106E-10SL-4S) MANUAL OVERRIDE DETAIL SERVO MUST BE DISCONNECTED

-B- CONTROL MTG. POSITION -A- CONTROL MTG. POSITION CONTROL SPRING OFF-SET TO FULL VOLUME CONTROL SPRING OFF-SET TO FULL VOLUME MANUAL MANUAL CONTROL ENERGIZE PORT PORT CONTROL ENERGIZE PORT PORT FIG. MOTOR OVERRIDE SHAFT FIG. MOTOR OVERRIDE SHAFT OPTION ROT. OPTION ROT. SOLENOID ROTATION "A" "B" SOLENOID ROTATION "A" "B"

1 CW CW INLET OUTLET 2 CW CCW INLET OUTLET "9A*" FULL SPEED "9A*" FULL SPEED 1 CCW CW OUTLET INLET 2 CCW CCW OUTLET INLET

.55 L7 SEE MANUAL OVERRIDE SEE MANUAL OVERRIDE (14,0) SEE TABLES 1-18 SHAFT DETAIL SHAFT DETAIL .19 MAX. VOL. LOCKNUT HEX RECESS x 3.17 (4,8) .12 (80,5) L7 DEEP 2.67 SEE TABLES 1-18 (3,0) (67,8)

5.12 O (130,1)

MANUAL OVERRIDE SHAFT DETAIL

O 5.12 MIN. VOLUME STOP (130,1) 2.67 (67,8) 3.17 MAX. VOL. LOCKNUT (80,5) MAX. VOLUME STOP MAX. VOLUME STOP MIN. VOLUME STOP FIGURE -1 FIGURE -2

Parker Hannifin Corporation Hydraulic Pump Division 42 Marysville, Ohio USA HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps Pump Secondary Control GOLD CUP® Series - Open & Closed Circuits

-A- CONTROL MTG. POSITION SERIES SIZE L7 L11L10 -B- CONTROL MTG. POSITION 6, 7 & 8 5.15 PORT PORT TORQUE (SAE 127-2) (130,9) 6.20 6.48 TORQUE CONTROL PUMP INPUT SHAFT CONTROL PUMP INPUT SHAFT PORT PORT FIG. LIMITER (157,4) (164,5) FIG. LIMITER OPTION ROT. ROTATION 6, 7 & 8 6.49 OPTION ROT. ROTATION "A" "B" ADJ. "A" "B" ADJ. (SAE 152-4) (164,8) 3 CW CW INLET OUTLET E 4 CW INLET OUTLET 6.38 5.83 5.83 CCW F 11 & 14 (162,0) (148,0) (148,0) 1 CCW CCW INLET OUTLET F 2 CCW CW INLET OUTLET E "**4" 8.14 7.15 7.15 "**4" CCW INLET INLET 1 CW OUTLET E 24 & 30 (206,7) (181,6) (181,6) 2 CCW CCW OUTLET F INLET 3 CW CCW OUTLET F 4 CW CW OUTLET INLET E "E" TORQUE LIMITER "F" TORQUE LIMITER ADJUSTMENT SCREW ADJUSTMENT SCREW

L7 L7

O

F F L10 L11

4.97 F O F (126,2)

1.40 "E" TORQUE LIMITER "F" TORQUE LIMITER 1.40 (35,5) FIGURE -1 ADJUSTMENT SCREW ADJUSTMENT SCREW FIGURE -2 (35,5)

"F" TORQUE LIMITER "E" TORQUE LIMITER ADJUSTMENT SCREW ADJUSTMENT SCREW

L7 L7

O

F F L11 L10

4.97 F O F (126,2)

1.40 FIGURE -3 "E" TORQUE LIMITER "F" TORQUE LIMITER 1.40 (35,5) ADJUSTMENT SCREW ADJUSTMENT SCREW FIGURE -4 (35,5)

Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA 43 HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps Pump & Motor Secondary Controls GOLD CUP® Series - Open & Closed Circuits

-A- CONTROL MTG. POSITION -B- CONTROL MTG. POSITION

CONTROL PORT PORT CONTROL PORT PORT FIG. PUMP INPUT SHAFT FIG. PUMP INPUT SHAFT OPTION ROT. ROTATION "A" "B" OPTION ROT. ROTATION "A" "B"

2 CW CW INLET OUTLET 1 CW CCW INLET OUTLET "**6" CCW INLET OUTLET "**6" CCW INLET OUTLET or 2 CCW or 1 CW "**8" 2 CW CCW OUTLET INLET "**8" 1 CW CW OUTLET INLET 2 CCW CW OUTLET INLET 1 CCW CCW OUTLET INLET

L7 L7

SEE TABLES 1-18 SEE TABLES 1-18

O

F F N/P M E A L R E SM Y C S T AS E R T IV L O U U S L H Y 040 E S S Y , S/N CI 34 RD L

UARD OIHO OI UA

L 4 HO ,E HO CI S 03 / Y S 4 N 0 Y H LLIVSY S U O T R E AS T M CE S R L A E M P/N

F O F

3.76 3.76 "**6" "**6" (95,5) MATING CONN. MATING CONN. (95,5) #721-30059 #721-30059 4.15 RED 4.15 +15VDC "**8" BB RED "**8" (105,4) FIGURE -2 8 D D FIGURE -1 (105,4) +15VDC BLUE OUT BL OUT C C C C 4 2 GREEN COMMON F F GN 7 B B C -15VDC BLACK WH DD -15VDC F F

DC RVDT DIAGRAM POTENTIOMETER DIAGRAM ("**8" REF.) ("**6" REF.)

-A- CONTROL MTG. POSITION -B- CONTROL MTG. POSITION

CONTROL PORT PORT CONTROL PORT PORT FIG. PUMP INPUT SHAFT FIG. PUMP INPUT SHAFT OPTION ROT. ROTATION "A" "B" OPTION ROT. ROTATION "A" "B"

2 CW CW INLET OUTLET 1 CW CCW INLET OUTLET 2 CCW CCW INLET OUTLET 1 CCW CW INLET OUTLET "**2" "**2" 2 CW CCW OUTLET INLET 1 CW CW OUTLET INLET 2 CCW CW OUTLET INLET 1 CCW CCW OUTLET INLET

L7 L7

SEE TABLES 1-18 SEE TABLES 1-18

O

F F

F O F

1.40 1.40 (35,5) FIGURE -2 FIGURE -1 (35,5)

Parker Hannifin Corporation Hydraulic Pump Division 44 Marysville, Ohio USA HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps Rear Adapters GOLD CUP® Series - Open & Closed Circuits

SAE Mounting and Coupling Blanking Mounting 82-2 (A) 101-2 (B) 101-4 (B) 127-2 (C) 127-4 (C) 152-4 (D) 165-4 (E) 177-4 (F) Plate Coupling None 16-4 (A) 22-4 (B) 22-4 (B) 32-4 (C) 32-4 (C) 44-4 (D) 44-4 (E) 50-4 (F)

P6/7/8 S, X M AB------

P6/7/8 R, L , M M AB-C----

P11/14 S, X M AB------

P11/14 R, L, M MABBCCDE Pump s

P24/30 S, X - -B-C----

P24/30 R, L, M M-BBCCDEF

M6/7/8 R, L, M, N M AB-C---- s M11/14 R, L, M, N MABBCCDE- Motor M24/30 R, L, M, N M-BBCCDEF

Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA 45 HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps 6,7,8 Rear Adapters GOLD CUP® Series - Open & Closed Circuits

P6-14 S,X SAE 82-2 (A) WITH COUPLING 16-4 SAE 101-2 (B) WITH COUPLING 22-4

Parker Hannifin Corporation Hydraulic Pump Division 46 Marysville, Ohio USA HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps 6,7,8 Rear Adapters GOLD CUP® Series - Open & Closed Circuits

2.40 MIN. SAE-"A" INTERNAL SPLINE DATA (61,0) M6,7 R,L,M,N .14 SAE-"B" INTE FLAT ROOT SIDE FIT J498B .29 P6,7,8 R,L,M 9 TEETH (3,6) X 45˚ FLAT ROOT SAE 127-2 (C) WITH COUPLING 32-4 16-32 PITCH (7,4) 13 TEETH 30˚ PRESSURE ANGLE 16-32 PITCH SAE 101-2 (B) WITH COUPLING 22-4 .6360-.6250 30˚ PRESSU MAJOR DIA. SAE 82-2 (A) WITH COUPLING 16-4 (16,154-15,875) .8860-.8750 .5139-.5089 (22,504-22,225 MINOR DIA. (13,053-12,926) .7583-.7533 (19,261-19,134) 2.09 (53,1) 2.40 MIN. 3.251 .08 3.253 (61,0) X 45˚ DIA. (2,0) 82,58 .40 SAE-"B" INTERNAL SPLINE DATA 82,63 4.19 (10,2) SAE-C INT FLAT ROOT SIDE FIT J498B (106,4) 13 TEETH FLAT ROOT 16-32 PITCH 14 TEETH 30˚ PRESSURE ANGLE 12-24 PITC .8860-.8750 SAE "A" MAJOR DIA. 30˚ PRESS (22,504-22,225 ) AUX. MTG. .75 2.88 1.2500-1.26 3/8 -16 UNC-2B TAP x DP. .7583-.7533 (19,0) MINOR DIA. (73,0) (31.750-32.0 .39 2 PLACES AS SHOWN (19,261-19,134) (9,9) 1.0862-1.09 MIN. 4.002 (27.589-27.7 1.38 4.006 SPLINE LENGTH DIA. (34,9) 101,65 5.75 101,75 (146,0) )A( 2-28 EAS 2-28 )A(

SAE "B" 1.00 1/2 -13 UNC-2B TAP x DP. .39 (25.4) AUX. MTG. 2 PLACES AS SHOWN .75 (9,9) P x DP. MIN. (19,0) N 1.38 SPLINE LENGTH (34,9)

2.24 MIN. )B( 2-101 EAS 2-101 )B( (56,9) .53 (13.5) .08 x45˚ (2.0) SAE-C INTERNAL SPLINE DATA FLAT ROOT SIDE FIT (J498B) 14 TEETH 12-24 PITCH 3.56 30˚ PRESSURE ANGLE 1.2500-1.2630 (90,4) MAJOR DIAMETER (31.750-32.080) 1.0862-1.0912 MINOR DIAMETER (27.589-27.716) 5.002 5.006 DIA. 127.05 127.15 7.12 (180,8) 1.00 SAE "C" P x DP. (25.4) WN AUX. MTG.

.74 MIN. (18,8) 1.32 SPLINE LENGTH (33,5) 1.00 5/8 -11 UNC-2B TAP x DP. (25.4) 2 PLACES AS SHOWN )C( 2-721 EAS 2-721 )C(

Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA 47 HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps 11,14 Rear Adapters GOLD CUP® Series - Open & Closed Circuits

M11,14 R,L,M,N P11,14 R,L BLANKING PLATE

M11,14 R,L,M,N P11,14 R,L,M SAE 82-2 (A) WITH COUPLING 16-4

Parker Hannifin Corporation Hydraulic Pump Division 48 Marysville, Ohio USA HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps 11,14 Rear Adapters GOLD CUP® Series - Open & Closed Circuits

M11,14 R,L,M,N P11,14 R,L,M SAE 101-2 (B) WITH COUPLING 22-4 SAE 101-4 (B) WITH COUPLING 22-4

M11,14 R,L,M,N P11,14 R,L,M SAE 127-2 (C) WITH COUPLING 32-4 SAE 127-4 (C) WITH COUPLING 32-4

Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA 49 HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps 11,14 Rear Adapters GOLD CUP® Series - Open & Closed Circuits

M11,14 R,L,M,N P11,14 R,L,M SAE 152-4 (D) WITH COUPLING 44-4

M11,14 R,L,M,N P11,14 R,L,M SAE 165-4 (E) WITH COUPLING 44-4

3.50 3.50 (88.9) 1.06 (88.9) (26.9)

Parker Hannifin Corporation Hydraulic Pump Division 50 Marysville, Ohio USA HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps P24, 30 Rear Adapters GOLD CUP® Series - Open & Closed Circuits

P24,30,S,X SAE 101-2 (B) WITH COUPLING 22-4

1.82 46,2

3.26 82,8

3.26 82,8

1.82 46,2

P24,30,S,X SAE 127-2 (C) WITH COUPLING 32-4 SAE 127-4 (C) WITH COUPLING 32-4

1.82 46,2

3.26 82,8

3.26 82,8

1.82 46,2

Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA 51 HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps 24, 30 Rear Adapters GOLD CUP® Series - Open & Closed Circuits

M24,30 R,L,M,N P24,30 R,L,M BLANKING PLATE

7/8"-9 UNC X 1.25 (31,8) DP. OVERHUNG SUPPORT FITTING

.67 (17.1)

M24,30 R,L,M,N P24,30 R,L,M SAE 101-2 (B) WITH COUPLING 22-4 SAE 101-4 (B) WITH COUPLING 22-4 5.750 SAE 22-4 ("B") (146,05 ) SAE 22-4 INTERNAL INVOLUTE SPLINE DATA 2.875 PER J498b 1969 FLAT ROOT SIDE FIT CLASS-1 2 BOLT MOUNT ( 73,02 ) 16/32 PITCH 1/2 -13 UNC X 1.00 DP. 30˚ PRESSURE ANGLE (25,4) 13 TEETH AS SHOWN .44 .7583-.7533 (19,261-19,134) MINOR DIA. (11,2 )

30 ˚

4.004 4.002 DIA. 101,69 ( 101,67 ) 4.21 DIA (107,0)

7/8"-9 UNC X SEALING "O" RING 1.25 (31,8) DP. ARP - 155 OVERHUNG SUPPORT FITTING 45˚

4 BOLT MOUNT .67 .52 1/2 -13 UNC X 1.00 DP. 13,2 (25,4) 2.52 ( 17,0 ) ON 5.000 BOLT CIRCLE MIN. (64,0) (127,00) SAE 101-2 ("B" 2 BOLT) EQUALLY SPACED SAE 101-4 ("B" 4 BOLT)

Parker Hannifin Corporation Hydraulic Pump Division 52 Marysville, Ohio USA HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps 24, 30 Rear Adapters GOLD CUP® Series - Open & Closed Circuits

M24,30 R,L,M,N P24,30 R,L,M SAE 127-2 (C) WITH COUPLING 32-4 SAE 127-4 (C) WITH COUPLING 32-4

1.31 (33,3) 45˚

.35. 35 2 BOLT MOUNT (13,5 ) 5/8 -11 UNC X 1.25 DP. (31,8) ON 7.125 BOLT CIRCLE (180,98) 90˚ AS SHOWN

30˚

5.004 5.002 DIA. 127.09 ( 127.07 ) 4 BOLT MOUNT 5.21 DIA (132,4) 1/2 -13 UNC X 1.00 DP. (25,4) ON 6.375 BOLT CIRCLE (161,93) 7/8"-9 UNC X EQUALLY SPACED SEALING "O" RING 1.25 (31,8) DP. ARP - 159 OVERHUNG SUPPORT FITTING

.54 .71 SAE 127-2 ("C" 2 BOLT) SAE 32-4 ("C") 13,7 SAE 32-4 INTERNAL INVOLUTE SPLINE DATA 3.82 ( 18,0 ) PER J498b 1969 ( 97,0 ) SAE 127-4 ("C" 4 BOLT) FLAT ROOT SIDE FIT CLASS-1 12/24 PITCH 30˚ PRESSURE ANGLE 1.0912-1.0862 (27,716-27,589) MINOR DIA.

M24,30 R,L,M,N P24,30 R,L,M SAE 152-4 (D) WITH COUPLING 44-4

1.31 (33,3)

.50 (12,7 )

30˚

8 BOLT MOUNT 3/4 -10 UNC THRU (1.31 DEEP REF.) 6.004 ON 9.000 BOLT CIRCLE 6.002 DIA. 152.46 (228,60) ( 152.44 ) 8 PLACES - EQUALLY SPACED AS SHOWN

6.21 DIA (157,8) SAE 44-4 ("D" & "E") 7/8"-9 UNC X SAE 44-4 INTERNAL INVOLUTE SPLINE DATA 1.25 (31,8) DP. PER J498b 1969 SEALING "O" RING OVERHUNG SUPPORT FLAT ROOT SIDE FIT CLASS-1 ARP - 163 FITTING 8/16 PITCH 30˚ PRESSURE ANGLE 13 TEETH 1.5110-1.5060 (38,379-38,252) MINOR DIA.

.54 .71 13,7 SAE 152-4 ("D" 4 BOLT) 3.82 ( 18,0 ) ( 97,0 )

Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA 53 HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps 24, 30 Rear Adapters GOLD CUP® Series - Open & Closed Circuits

M24,30 R,L,M,N P24,30 R,L,M 1.31 SAE 165-4 (E) WITH COUPLING 44-4 (33,3) .64 4 BOLT MOUNT 16.52 DIA (16,3 ) 3/4-10 UNC THRU (419,6) ON 12.500 BOLT CIRCLE (317,50) 4 PLACES - EQUALLY SPACED

˚30

6.504 6.502 DIA. 165.14 ( 165.12 )

6.71 DIA (170,6)

7/8"-9 UNC X 1.25 (31,8) DP. SEALING "O" RING OVERHUNG SUPPORT ARP - 165 FITTING

SAE 44-4 ("D" & "E") SAE 44-4 INTERNAL INVOLUTE SPLINE DATA .54 .71 PER J498b 1969 FLAT ROOT SIDE FIT CLASS-1 13,7 3.82 ( 18,0 ) SAE 165-4 ("E" 4 BOLT) 8/16 PITCH ( 97,0 ) 30˚ PRESSURE ANGLE 13 TEETH 1.5110-1.5060 (38,379-38,252) MINOR DIA.

M24,30 R,L,M,N P24,30 R,L,M 1.31 SAE 177-4 (F) WITH COUPLING 50-4 (33,3) .64 16.52 DIA (16,3 ) (419,6)

4 BOLT MOUNT 1" -8 UNC X 1.31 DP. 4-PLACES (33,3)

˚30

9.75 SQUARE (247,6 )

7.001 7.003 DIA. 177,82 ( 177,88 )

7.28 DIA 4.88 (184,9) (123,8 )

7/8"-9 UNC X 1.25 (31,8) DP. OVERHUNG SUPPORT SEALING "O" RING FITTING ARP - 167

SAE 50-4 ("F") SAE 50-4 INTERNAL INVOLUTE SPLINE DATA .54 .71 PER J498b 1969 FLAT ROOT SIDE FIT CLASS-1 13,7 8/16 PITCH 3.82 ( 18,0 ) ( 97,0 ) SAE 177-4 ("F" 4 BOLT) 30˚ PRESSURE ANGLE 15 TEETH 1.7524-1.7574 (44,511-44,638) MINOR DIA.

Parker Hannifin Corporation Hydraulic Pump Division 54 Marysville, Ohio USA HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps Inlet Conditions GOLD CUP® Series - Open & Closed Circuits

INLET CONDITIONS AT SEA LEVEL INLET CONDITIONS AT SEA LEVEL 21.7 1.50 21.7 1.50 AISP ,erusserp etulosbA ,erusserp AISP AISP ,erusserp etulosbA ,erusserp AISP 20.7 1.43 20.7 etulosbA ,erusserp 1.43 raB aB aB 19.7 1.36 19.7 1.36

18.7 1.29 russe 18.7 1.29 17.7 1.22 17.7 1.22

16.7 1.15 r,r 16.7 1.15

15.7 1.08 etulosb 15.7 1.08 14.7 1.01 14.7 1.01 13.7 0.95 13.7 0.95 Ape 12.7 0.88 12.7 0.88 11.7 0.81 11.7 0.81 10.7 0.74 10.7 0.74 1200 1400 1600 1800 2000 2200 2400 1200 1400 1600 1800 2000 2200 2400 Speed, RPM Speed, RPM P6V & P6F P7V & P7F

INLET CONDITIONS AT SEA LEVEL 21.7 1.50

AISP ,erusserp etulosbA ,erusserp AISP 20.7 1.43 19.7 1.36 18.7 1.29

17.7 1.22 ss 16.7 1.15 e Bar re,

15.7 1.08 et uru 14.7 1.01 s

13.7 0.95 bl p Ao 12.7 0.88 11.7 0.81 10.7 0.74 1200 1400 1600 1800 2000 2200 2400 Speed, RPM P8V & P8F

INLET CONDITIONS AT SEA LEVEL INLET CONDITIONS AT SEA LEVEL 21.7 1.50 21.7 1.50 AISP ,erusserp etulosbA ,erusserp AISP AISP ,erusserp etulosbA ,erusserp AISP 20.7 1.43 20.7 etulosbA ,erusserp 1.43 raB aB aB 19.7 1.36 19.7 1.36

18.7 1.29 russe 18.7 1.29 17.7 1.22 17.7 1.22

16.7 1.15 r,r 16.7 1.15

15.7 1.08 etulosb 15.7 1.08 14.7 1.01 14.7 1.01 13.7 0.95 13.7 0.95 Ape 12.7 0.88 12.7 0.88 11.7 0.81 11.7 0.81 10.7 0.74 10.7 0.74 1200 1400 1600 1800 2000 2200 2400 1200 1400 1600 1800 2000 2200 2400 Speed, RPM Speed, RPM P11V P14V

Note: The absolute inlet pressure is the pressure required to fill the pump with petroleum based fluids. The maximum pressure in the inlet port is 200 psi, 14 bar. For unboosted systems, the diameter of the suction line must be sized to allow a maximum velocity not higher than 4 ft/sec. A coarse screen may be considered in the suction line, no filter. For water in oil invert emulsions and water glycols increase the inlet absolute pressure by 25%, for phosphate ester increase the absolute inlet pressure by 35%. Any inlet pressures above atmospheric may increase noise levels and decrease effi- ciencies noted in this literature. Please consult your nearest Parker Office for further details.

Inlet characteristics-auxiliary pump, port C Series Speed Displacement Pressure absolute rpm in3/rev cm3/rev psi bar 6, 7, 8, 11, 14 1200 1.07 17,5 9.5 0,66 6, 7, 8, 11, 14 1800 1.07 17,5 9.5 0,66 6, 7, 8, 11, 14 2400 1.07 17,5 10.5 0,72 24, 30 1200 4.84 79,3 9.5 0,66 24, 30 1800 4.84 79,3 10.5 0,72

Note: Maximum pressure on inlet port C is 200 psi, 14 bar.

Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA 55 HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps Performance Curves U.S./METRIC GOLD CUP® Series - Open & Closed Circuits

PRESSURE - PSI PRESSURE - BAR

Performance curves Series 6 Performance curves Series 6 Pump at full displacement Pump at full displacement

SPEED - RPM SPEED - RPM

Performance curves Series 6 Performance curves Series 6 Motor at full displacement Motor at full displacement

Parker Hannifin Corporation Hydraulic Pump Division 56 Marysville, Ohio USA HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps Performance Curves U.S./METRIC GOLD CUP® Series - Open & Closed Circuits

PRESSURE - PSI PRESSURE - BAR

Performance curves Series 7 Performance curves Series 7 Pump at full displacement Pump at full displacement

SPEED - RPM SPEED - RPM

Performance curves Series 7 Performance curves Series 7 Motor at full displacement Motor at full displacement

Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA 57 HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps Performance Curves U.S./METRIC GOLD CUP® Series - Open & Closed Circuits

PRESSURE - PSI PRESSURE - BAR

Performance curves Series 8 Performance curves Series 8 Pump at full displacement Pump at full displacement

Parker Hannifin Corporation Hydraulic Pump Division 58 Marysville, Ohio USA HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps Performance Curves U.S./METRIC GOLD CUP® Series - Open & Closed Circuits

PRESSURE - PSI PRESSURE - BAR

Performance curves Series 11 Performance curves Series 11 Pump at full displacement Pump at full displacement

SPEED - RPM SPEED - RPM

Performance curves Series 11 Performance curves Series 11 Motor at full displacement Motor at full displacement

Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA 59 HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps Performance Curves U.S./METRIC GOLD CUP® Series - Open & Closed Circuits

PRESSURE - PSI PRESSURE - BAR

Performance curves Series 14 Performance curves Series 14 Pump at full displacement Pump at full displacement

SPEED - RPM SPEED - RPM

Performance curves Series 14 Performance curves Series 14 Motor at full displacement Motor at full displacement

Parker Hannifin Corporation Hydraulic Pump Division 60 Marysville, Ohio USA HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps Performance Curves U.S./METRIC GOLD CUP® Series - Open & Closed Circuits

*PRESSURE-BAR * PRESSURE - PSI * PRESSURE - BAR

Performance curves Series 24 Performance curves Series 24 Pump at full displacement Pump at full displacement

* PRESSURE - PSI * PRESSURE - BAR

Performance curves Series 30 Performance curves Series 30 Pump at full displacement Pump at full displacement

Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA 61 HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps Pump Primary Displacement Control Options GOLD CUP® Series - Open & Closed Circuits

CODE DESCRIPTION HYDRAULIC CIRCUIT

TO VANE CHAMBERS

10 MANUAL SCREW ADJUST

SERVO

TO VANE CHAMBERS

2A TWO POSITION CONTROL

SERVO

TO VANE CHAMBERS

2H 3 POSITION CONTROL

SERVO

TO VANE CHAMBERS

2 POSITION CONTROL WITH 2M CEPTOP3, NG6 VALVE SERVO

Parker Hannifin Corporation Hydraulic Pump Division 62 Marysville, Ohio USA HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps Pump Primary Displacement Control Options GOLD CUP® Series - Open & Closed Circuits

TYPICAL PERFORMANCE DESCRIPTION OF OPERATION

CAM ANGLE

o 19 Spring loaded toward maximum displacement, with an adjustment screw to limit the displacement anywhere between 0% and 100%. A minimum volume stop is also supplied so that when the rotary servo

o 19 shaft is turned, the displacement can be varied only between the o 19 minimum and maximum settings. SHAFT ROTATION Torque required to rotate servo shaft: 20 lb-in, 2.56 Nm. o 19

CAM ANGLE

Hydraulically piloted non-proportionally between adjustable minimum o 19 and maximum displacements. The control is spring loaded toward minimum when used on pumps, to maximum on motors. Servo pres- sure is switched by an external valve to drive the control in either direction. When used on motors, the minimum setting can be set no o 19 lower than 30% of maximum. MIN MAX SERVO SHAFT ROTATION

CAM ANGLE

o 19 Hydraulically piloted non-proportionally between an adjustable

3 minimum displacement of 0±5% and two fully adjustable maximum o 19 displacements, one in either direction, and spring loaded toward o 2 19 minimum. Servo pressure is switched by an external valve to drive the 1 SHAFT control in either direction. ROTATION

o 19

CAM ANGLE

Same as 2A except a CEPTOP3, NG6 two position directional valve o 19 is mounted to the control. With the solenoid de-energized, the control is spring loaded to zero for pumps and to maximum displacement for motors. Energizing the solenoid drives the control toward maximum displacement on pumps, minimum on motors. When used on motors, o 19 the minimum settings can be no less than 30% of maximum.

SHAFT ROTATION

Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA 63 HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps Pump Primary Displacement Control Options GOLD CUP® Series - Open & Closed Circuits

CODE DESCRIPTION HYDRAULIC CIRCUIT

TO VANE CHAMBERS

3 POSITION CONTROL 2N WITH CEPTOP3, NG6 VALVE SERVO

TO VANE CHAMBERS

SPRING CENTERED 40 ROTARY SERVO

SERVO

TO VANE CHAMBERS

SPRING CENTERED ROTARY 4A SERVO WITH ADJUSTABLE STOPS

SERVO

TO VANE CHAMBERS

SERVO SPRING CENTERED ROTARY SERVO WITH AUTOMATIC 4B BRAKE AND BYPASS CONTROL

BRAKE REPLENISHING

Parker Hannifin Corporation Hydraulic Pump Division 64 Marysville, Ohio USA HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps Pump Primary Displacement Control Options GOLD CUP® Series - Open & Closed Circuits

TYPICAL PERFORMANCE DESCRIPTION OF OPERATION

CAM ANGLE

o 19 Same as 2H except a CEPTOP3, NG6 three position directional valve is mounted to the control. With the solenoids de-energized, the control is spring loaded to zero. Energizing a solenoid drives the control toward 3 o 19 maximumdisplacement in one of the two directions. o 2 19 1 SERVO SHAFT ROTATION

o 19

CAM ANGLE The 40 is the basic displacement control for all Goldcup. It is actuated by STROKE RATE a servo shaft that is rotated from 0º - 19º, either side of center. This action o ZERO TO MAXIMUM 19 opens a unique slide valve to port servo oil to and from the vane cham- P6,7,8 0.8 SEC P11,14 1.5 SEC bers that actuate the rocker cam. Vanes, integral to the cam, move the P24, 30 1.8 SEC cam so that it follows the rotary servo input shaft motion exactly. When o 19 the cam reaches the position equal to that of the input shaft, the slide o 19 valve closes. Any cam motion due to pumping forces immediately opens SHAFT ROTATION the slide valve to correct the cam position. ANGLE

o 19 Springs cause the control to return to zero stroke when no external force is applied to the servo shaft. An adjustment is provided to locate the exact zero position, to prevent machine creep.

CAM ANGLE

o 19 The 4A control is the same as the 40, with addition of adjustable maxi- mum volume stop screws, with locking caps, to limit the control to less than 100% displacement. Stops are present on both sides of center and

o 19 may be set independently to different settings. o 19

SERVO SHAFT ROTATION ANGLE

o 19

The 4B control is the same as the 4A control, application of an on-stroke motion at the rotary servo shaft, with the addition of an output port that will pro- and that cause the brake to remain released even after the vide servo pressure to control a spring applied, rotary servo shaft is recentered, until the pump rocker cam pressure released parking brake. The control actually returns to zero, at which time the brake will set. Ad- contains anticoincidence functions that cause ditionally, a small bypass is opened between the pump A & the brake to release immediately upon B ports to bypass any flow that is generated if the pump is CAM ANGLE not exactly zeroed. The bypass closes whenever the brake is released.

o 19 BRAKE PRESSURE HIGH BYPASS CLOSED

o 19 o 19 SERVO SHAFT ROTATION ANGLE o o 19 19 o o 19 ±2 BRAKE PRESSURE LOW BYPASS OPEN

Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA 65 HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps Pump Primary Displacement Control Options GOLD CUP® Series - Open & Closed Circuits

CODE DESCRIPTION HYDRAULIC CIRCUIT

TO VANE CHAMBERS

SPRING CENTERED BRAKE AND 4C ADJUSTABLE BYPASS CONTROL (AUTOMATIC BRAKE CONTROL)

SERVO

TO VANE CHAMBERS

5A ELECTROHYDRAULIC CONTROL

SERVO

TO VANE CHAMBERS

8A HYDRAULIC STROKER P2 P1

SERVO

Parker Hannifin Corporation Hydraulic Pump Division 66 Marysville, Ohio USA HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps Pump Primary Displacement Control Options GOLD CUP® Series - Open & Closed Circuits

TYPICAL PERFORMANCE DESCRIPTION OF OPERATION

CAM ANGLE

o 19

o This control combines the features of the 4A and 4B controls.See 19 o 19 above descriptions.

SERVO SHAFT ROTATION ANGLE

o 19

CAM ANGLE

o 19 The 5A control controls displacement in proportion to an electric cur- rent between zero and 350 milliamps. The control is available with or

IMAX without a 10% deadband. Positive polarity drives the control in one IMAX direction, and negative polarity in the other. Adjustable maximum INPUT CURRENT displacement stops are included. The 5C option, with automatic brake control, is also available. DEADBAND o 19

CAM ANGLE

o 19 The 8A control controls displacement in proportion to a hydraulic pressure, values listed below. Pressure applied in the P1 port drives

PIMAX MAX the pump on stroke in one direction, P2 port in the other. Adjustable PIMAX MAX maximum displacement stops are included. The 8C option, with automatic brake control, is also available.

o 19

Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA 67 HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps Pump Primary Displacement Control Options GOLD CUP® Series - Open & Closed Circuits

CODE DESCRIPTION HYDRAULIC CIRCUIT

TO VANE CHAMBERS

9A ELECTRIC STROKER

SERVO

TO VANE CHAMBERS

COMMAND

7D6 7D8 HIGH IQ SERVOVALVE 7F6 CONTROL SERVO FEEDBACK 7F8 (POTENTIOMETER COMPENSATOR OR RVDT PILOT (V PORT)

Parker Hannifin Corporation Hydraulic Pump Division 68 Marysville, Ohio USA HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps Pump Primary Displacement Control Options GOLD CUP® Series - Open & Closed Circuits

ECNAMROFREP LACIPYT ECNAMROFREP NOITPIRCSED FO NOITAREPO ECNAMROFREP LACIPYT ECNAMROFREP NOITPIRCSED FO NOITAREPO TYPICALLACIPYT PERFORMANCE ECNAMROFREP DESCRIPTIONNOITPIRCSED FO OF OPERATIONNOITAREPO The 9A control controls displacement in proportion to an electric current The 9A control controls displacement in proportion to an electric current between zero and 350 milliamps for the 24 volt version, and up to 650 milliamps ECNAMROFREP LACIPYT ECNAMROFREP The 9A controlbetween controls zero displacement and 350 milliampsNOITPIRCSED in FO proportion for the to 24NOITAREPO an voltelectric version, current and up to 650 milliamps for the 12 volt version. The control signal is a Pulse Width Modulated signal. betweenThe zero 9Afor and control the 350 12 milliamps voltcontrols version for displacement. theThe 24 control volt version, signal in proportion andis a upPulse to 650 toWidth anmilliamps electricModulated current signal. Current signal to one coil drives the pump in one direction, and to the other for thebetween 12 voltCurrent version zero .signal andThe control350 to one milliamps signal coil drivesis a forPulse thethe Width pump 24 volt Modulated in oneversion, direction, signal. and upand to to 650 the othermil- The 9A coilcontrol in the controls opposite. displacement Adjustable in proportionmaximum todisplacement an electric current stops are included. betweenCurrentliamps zerosignal coiland for to in 350onethe the milliampscoil12 opposite. voltdrives version. for the Adjustablethe pump 24 The volt in version,controlonemaximum direction, andsignal displacement up and to is 650 toa Pulsethe milliamps other stops Width are Modulated included. The 9C option, with automatic brake control, is also available. forcoil the in signal.12 the volt opposite. Theversion Current 9C .Adjustable option,The signal control with tomaximum signal oneautomatic coilis a displacement Pulsedrives brake Width thecontrol, Modulatedpumpstops is arealsoin oneincluded.signal. available. direction, and to CurrentThe 9Cthe signal option, other to with onecoil automatic coilin the drives opposite. brake the pump control, Adjustable in one is also direction, available.maximum and to displacement the other stops are coil in the opposite. Adjustable maximum displacement stops are included. CAM ANGLE included. The 9C option, with automatic brake control, is also available. CAM ANGLE The 9C option, with automatic brake control, is also available. CAM ANGLE Specifications: Specifications: Specifications: siseretsyH %5 ,lacipyt %8 mumixam o 19 siseretsyH %5 ,lacipyt %8 mumixam CAM ANGLE o siseretsyH tiraeniL y %5 ,lacipyt %8 %8 mumixam o 19 tiraeniL y %8 19 tiraeniL y esnopseR %8 8,7,6P .0 9 ,sdnoces orez ot lluf ekorts ro ab ck Specifications: esnopseR 8,7,6P 9.0 ,sdnoces orez ot lluf ekorts ro ab ck esnopseR 8,7,6P P11,14 9.0 1.5,sdnoces seconds,orez ot lluf zeroekorts toro fullab ck stroke or back siseretsyH %5 ,lacipyt %8 P11,14mumixam 1.5 seconds, zero to full stroke or back o P11,14 P24, 1.5 30 seconds, 1.8 zero seconds, to full stroke zero toor fullback stroke or back 19 tiraeniL y %8 P24, 30 1.8 seconds, zero to full stroke or back IMAX Repeatability P24, 30 2% 1.8 seconds, zero to full stroke or back esnopseR Repeatability 8,7,6P 9.0 2% ,sdnoces orez ot lluf ekorts ro ab ck IMAX IMAX IMAX RepeatabilityTemperature null shift 2% <2% per 100ºF (38º C) IMAX Temperature nullP11,14 shift 1.5 seconds,<2% per zero 100ºF to full (38ºstroke C) or back IMAX TemperatureServo null pressure shift required<2% per 100ºF 200-1000 (38º C)psi (14-70 bar), 400 nominal (28 bar) Servo pressureP24, required 30 1.8 seconds, 200-1000 zero psi to full(14-70 stroke bar), or back400 nominal (28 bar) INPUT Servo pressureCoil resistance required 200-1000 psi41 (14-70ohms bar), 400 nominal (28 bar) Repeatability 2% (24v coil) & 10 ohms (12v coil) IMAX INPUTCURRENTINPUTCoil resistance Coil resistance 41 ohms (24v coil) 41& 10 ohms ohms (24v (12v coil) coil) & 10 ohms (12v coil) IMAX TemperatureElectrical null shift input* <2% per 100ºF 270 (38ºma minimum,C) 325 ma nominal, 380 ma maximum (24v coil) CURRENTo CURRENTElectrical input* Electrical input* 270 ma minimum, 325270 ma nominal,minimum, 380 325 ma ma maximum nominal, 380 ma maximum (24v coil) (24v coil) o 19 o Servo pressureNeutral required deadband* 200-1000 psi150 (14-70 ma minimum,bar), 400 nominal 180 ma (28 nominal, bar) 210 ma maximum (24v coil) 19 19 Neutral deadband*Neutral deadband* 150 ma minimum, 180150 mama nominal,minimum, 210 180 ma ma maximum nominal, (24v 210 coil) ma maximum (24v coil) INPUT Coil resistanceManual override 41 ohms 3/16" Allen wrench, 30 in-lb (3.4Nm) with zero signal Manual override Manual override3/16" Allen (24v wrench, coil) &3/16" 1030 ohmsin-lb Allen (3.4Nm) (12v wrench, coil) with 30 zero in-lb signal (3.4Nm) with zero signal CURRENT Fluid types All ElectricalFluid types input* 270All ma minimum, 325 ma nominal, 380 ma maximum (24v coil) o Fluid types All 19 Neutral deadband* 150 ma minimum, 180 ma nominal, 210 ma maximum (24v coil) Manual overrideAvailable 3/16" Allen wrench,Jupiter 90030 in-lb card (3.4Nm) with zero S20-14078 signal Available Available Jupiter 900 card Jupiter 900 S20-14078card S20-14078 Fluidopen-loop typesopen-loop drivers drivers All Dual Driver module 027-22071-0 open-loop driversDual Driver moduleDual Driver 027-22071-0module 027-22071-0 Power supply 762-30026-0 Power supply Power supply762-30026-0 762-30026-0 Available JupiterEuro card 900 Euroholdercard card holder S20-14078 EX00-S07 EX00-S07 open-loop drivers Dual Driver module Euro card 027-22071-0holder EX00-S07 ElectricalElectrical connector connector DIN 43650DIN type 43650 AF, 16-01008-8 type AF, 16-01008-8 Electrical connector DIN 43650 type AF, 16-01008-8 Fluid cleanlinessFluid cleanliness PowerNAS 1638,supplyNAS class 1638, 8 or ISO class 17/14 8762-30026-0 or ISO 17/14 Fluid cleanlinessEuro card holder NAS 1638,EX00-S07 class 8 or ISO 17/14 Electrical* 12V* coils*connector 12V12V are coilscoils twice are these twicetwiceDIN 43650values. these these type values. AF, values 16-01008-8 Fluid cleanliness * 12V coils NASare 1638,twice class these 8 or ISO values. 17/14

* The12V 7**coilsTheThe control are 7**7** twicecontrol is a highthese isis responsea avalues. high high response response displacement displacement displacement control that control uses control thata servo- thatuses usesa servo- CAM ANGLE The 7** control is a high response displacement control that uses a servo- CAM ANGLE valve tovalve direct to highdirect flow high levels flow to levels and from to and the fromvane thechambers, vane chambers, in order to in order to CAM ANGLE a servovalvevalve to todirect direct high high flow flow levels levels to and to from and thefrom vane the chambers, vane chambers, in order into Theachieve 7**orderachieve control high to stroke ishighachieve a high ratesstroke response high on rates the stroke pump. ondisplacement the rates A pump. feedback on control Athe feedback potentiometer pump. that uses potentiometerA feedback a or servo- RVDT potentiometer or RVDT CAM ANGLE (Rotary Variableachieve Differential high stroke Transformer) rates on is the used pump. to feed A feedbackback the rockerpotentiometer or RVDT o valve to(Rotary direct high Variable flow levels Differential to and Transformer)from the vane is chambers, used to feed in order back to the rocker 19 o or RVDT(Rotary (Rotary Variable Variable Differential Differential Transformer) Transformer) is used isto usedfeed back to feed the backrocker 19 achievecam position high stroke to the rates controlling on the electronics pump. A feedback to achieve potentiometer stable operation. or RVDT o thecam rocker position cam to theposition controlling to the electronics controlling to electronicsachieve stable to achieveoperation. stable 19 (Rotary Variablecam Differential position to Transformer) the controlling is used electronics to feed back to achieve the rocker stable operation. o The 7D6operation. control uses a servovalve and a feedback potentiometer for feed- 19 cam positionThe 7D6 to the control controlling uses electronicsa servovalve to achieveand a feedback stable operation. potentiometer for feed- back, the 7D8The uses 7D6 an control RVDT. uses a servovalve and a feedback potentiometer for feed- 100% Theback, 7D6 the control7D8 uses uses an RVDT.a servovalve and a feedback potentiometer for 100% The 7D6 controlback, uses the a 7D8servovalve uses an and RVDT. a feedback potentiometer for feed- 100% 100% feedback, the 7D8 uses an RVDT. 100% back,The 7F6the 7D8control uses uses an servovalveRVDT. and a the feedback potentiometer, but also 100% COMMAND 100% The 7F6 control uses servovalve and a the feedback potentiometer, but also COMMAND has aThe special 7F6The valve control 7F6 block control uses with uses aservovalve valve servovalve in it to and shut and a off the a the the feedback servovalve, feedback potentiometer, potentiometer,so that butbut also 100% COMMANDcontrolhas may a bespecial taken valveover byblock a 4A2 with control a valve also in mountedit to shut to off the the pump servovalve, as a so that o The 7F6has control a hasspecial uses a special servovalvevalve valve block and block with a the with a feedbackvalve a valve in itpotentiometer,in to it shutto shut off off the but the servovalve,also servovalve, soso thatthat 19 COMMAND manualcontrol override. may The be 7F8 taken is theover same, by a except4A2 control using alsoan RVDT. mounted to the pump as a o has a special controlvalve block may withbe takena valve over in it by to ashut 4A2 off control the servovalve, also mounted so that to the pump as a 19 o controlmanual may override. be taken The 7F8 over is bythe a same, 4A2 controlexcept usingalso mountedan RVDT. to the pump as a 19 control may bemanual taken overoverride. by a The4A2 control7F8 is thealso same, mounted except to the using pump an as RVDT. a o Specifications for 7D,7F: manual override. The 7F8 is the same, except using an RVDT. 19 manual override. The 7F8 is the same, except using an RVDT. Specifications for 7D,7F: 8,7,6P 41,11P 03/42P Specifications for 7D,7F: siseretsyH <± %1 8,7,6P <±1% 41,11P ±1% 03/42P Specifications for 7D,7F: 8,7,6P 41,11P 03/42P ytiraeniL siseretsyH <± %5.0 <± %1 <±0.5% <±1% ±0.5% ±1% siseretsyH 8,7,6P < %1 41,11P < 1% 03/42P 1% esnopseR petS esnopseR ytiraeniL sm081 <± %5.0 ± 003 sM <±0.5% ± 063 sM ±0.5% ± siseretsyH <± %1 <±1% ±1% Small SignalpetS FrequencyesnopseR ytiraeniL Response 10 Hz, 400 psi (28sm081 < bar)± %5.0 8.2 Hz,, 440 psi003 (30sM

Parker Hannifin Corporation Hydraulic Pump Division 68 Marysville, Ohio USA 69 HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps Secondary Control Options GOLD CUP® Series - Open & Closed Circuits

CODE DESCRIPTION HYDRAULIC CIRCUIT

TO VANE CHAMBERS

7J6 HIGH IQ COMPENSATOR PILOT (VPORT) 7J8 DF+ CONTROL 7K6 PROPORTIONAL 7K8 VALVE

CAM POSITION ELECTRONICS FEEDBACK

COMMAND

TO VANE CHAMBERS

TORQUE LIMITER --4 OVERRIDE

Parker Hannifin Corporation Hydraulic Pump Division 70 Marysville, Ohio USA HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps Secondary Control Options GOLD CUP® Series - Open & Closed Circuits

TYPICAL PERFORMANCE DESCRIPTION OF OPERATION

The 700 controls are high response displacement controls that use propor- CAM ANGLE tional directional flow control valves to direct high flow levels to and from the vane chambers, in order to achieve high stroke rates on the pump A feedback potentiometer or RVDT (Rotary Variable Differential Transformer) is used to feed back the rocker cam position to the controlling electronics to achieve o 19 stable operation. The 7J6 control uses a proportional directional control valve and a feedback potentiometer for feedback, the 7J8 uses an RVDT. 100% 100% The 7K6 control uses proportional directional control valve and a the feedback COMMAND potentiometer, but also has a special valve block with a valve in it to shut off the servovalve, so that control may be taken over by a 4A2 control also o 19 mounted to the pump as a manual override. The 7K8 is the same, except using an RVDT.

Specifications for 7J, 7K 8,7,6P 41,11P 03/42P siseretsyH <± %1 <±1% <±1% ytiraeniL <± %9.0 <±0.9% ±0.9% esnopseR petS esnopseR 081 sm 003 sm 003 sm Small Signal Frequency Response 16 Hz, 400 psi (28 bar) 12 Hz,, 440 psi (30 bar) 8Hz,, 500 psi (35 bar) 25 Hz,, 1000 psi (70 bar) 20 Hz,, 1000 psi (70 bar) 10 Hz,, 1000 psi (70 bar) erusserP ovreS erusserP 0001 isp 07( )rab lanimon Coil Resistance 4 ohms

Feedback Pot Output ±3 VDC at 19º, 15 VDC excitation Feedback RVDT Output, ±2.4 VDC at 19º, 15 VDC excitation sepyT diulF sepyT llA ssenilnaelC diulF ssenilnaelC SAN ,8361 ssalc 8 ro OSI 41/71 Available Drivers Digital EC01 cards (see publication LT3-00055-1) Electrical Connector

The **4 control option can be added to any other control, except TORQUE the 7**, and will limit the amount of torque accepted by the drive shaft on the pump by reducing displacement if the product of pressure and flow (displacement) exceed a preset value. This will allow the pump to go to full stroke, but not at maximum pressure, and it will allow the pump to go to full o 19 pressure, but not at maximum flow. When the condition causing the overload o 19 disappears, the pump control reverts to the main displacement control. The pressure compensator override is always in effect, at all times, and its function is not effected by this control in any way. Minimum setting is 25% of maximum input torque. P (5000 (PSI) x MAX Displacement / 2›

0 15 0 15

Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA 71 HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps 6,7,8 Hydraulic Schematics (Closed Circuit) GOLD CUP® Series - Open & Closed Circuits

Series 6, 7 & 8 Information 3/8"-16UNC-2A x 1/2" SOC. SETSCREW PACKAGE PUMP (NYLOK OR SPOTLOK) INSTALL IN PORT H. ONLY IF PORT G CONNECTS EXTERNALLY TO TO PORT H C G D1

D2

DG CONTROL FB OPTIONS FA RECOMMENDED EXTERNAL FILTER THE MAXIMUM PRESSURE BG DROP IN THE FILTER H CIRCUIT SHOULD NOT EXCEED 150 PSI UNDER COLD START CONDITIONS 1/2A AG

A 1/2A K (OPTIONAL)

40 PSI (2.8 BAR) RELIEF-OPTIONAL (RECOMMENDED FOR CIRCUITS WITH PUMP

SPEEDS INTERMITTENTLY 2A 2A BELOW 1000 RPM-SEE PAGE 6)

A A OPTIONAL LINE

B VB V KG VA A

NOTE: See pages 75 or 76 for the Open Circuit Pump Operational Notes

PACKAGE MOTOR FIXED D1 D2 DISPLACEMENT

D

PACKAGE MOTOR VARIABLE ABDISPLACEMENT FROM PORT G ON PUMP H2 CONTROL OPTIONS (2A0 SHOWN) FROM PORT G X A P ON PUMP H1 Y B T OPTIONAL LINE FA FB

D D2 CUSTOMER FURNISHED DIRECTIONAL VALVE

DG D1

Parker Hannifin Corporation Hydraulic Pump Division 72 Marysville, Ohio USA HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps 11,14 Hydraulic Schematics (Closed Circuit) GOLD CUP® Series - Open & Closed Circuits

Series 11 & 14 Information PACKAGE PUMP

C G2 C

A D1 G

B D2

C DG CONTROL OPTIONS 1/8-27 NPTF PIPE FB FA PLUG INSTALLED ONLY IF PORT "J" CONNECTS EXTERNALLY TO PORT "K". INSERT BG 1/8" PLUG UNDER AG PLUG ON FACE OF PORT BLOCK

1/2A

J A 1/2A

40 PSI (2.8 BAR) K RELIEF-OPTIONAL (RECOMMENDED FOR CIRCUITS WITH PUMP

SPEEDS INTERMITTENTLY 2A 2A BELOW 1000 RPM-SEE PAGE 6) RECOMMENDED C C EXTERNAL FILTER BG2 A AG2 A THE MAXIMUM PRESSURE OPTIONAL LINE DROP IN THE FILTER CIRCUIT SHOULD NOT EXCEED 150 PSI UNDER COLD START CONDITIONS PLUG ON FACE OF PORT BLOCK B VB V KG VA A

NOTE: See pages 75 or 76 for the Open Circuit Pump Operational Notes

PACKAGE MOTOR FIXED D D2 DISPLACEMENT

C C DG D1

D PACKAGE MOTOR ABVARIABLE AG DISPLACEMENT FROM PORT G BG ON PUMP H2 CONTROL OPTIONS (2A0 SHOWN) FROM PORT G X A P ON PUMP H1 Y B T OPTIONAL LINE FA FB

D D2 CUSTOMER FURNISHED DIRECTIONAL VALVE

DG D1

Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA 73 HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps 24,30 Hydraulic Schematics (Closed Circuit) GOLD CUP® Series - Open & Closed Circuits

Series 24 & 30 Information PACKAGE PUMP

C G

D1 CAUTION: EXTERNAL LINE MUST BE CONNECTED BETWEEN PORT G AND H1 PRIOR TO D2 START-UP OR DAMAGE WILL OCCUR TO AUX. PUMP DG CONTROL FB OPTIONS FA

H2

H

BG1 1/2A AG1

A 1/2A K (OPTIONAL) RECOMMENDED 40 PSI (2.8 BAR) EXTERNAL FILTER RELIEF-OPTIONAL THE MAXIMUM PRESSURE (RECOMMENDED FOR DROP IN THE FILTER CIRCUITS WITH PUMP CIRCUIT SHOULD NOT SPEEDS INTERMITTENTLY 2A 2A EXCEED 150 PSI UNDER BELOW 1000 RPM-SEE COLD START CONDITIONS PAGE 6)

A A OPTIONAL LINE BG2 AG2

B VB V KG VA A

NOTE: See pages 75 or 76 for the Open Circuit Pump Operational Notes

PACKAGE MOTOR FIXED D1 D2 DISPLACEMENT

DG D

PACKAGE MOTOR VARIABLE ABDISPLACEMENT FROM PORT G ON PUMP H2 CONTROL OPTIONS (2A0 SHOWN) FROM PORT G X A P ON PUMP H1 Y B T OPTIONAL LINE FA FB

D D2 CUSTOMER FURNISHED DIRECTIONAL VALVE

DG D1

Parker Hannifin Corporation Hydraulic Pump Division 74 Marysville, Ohio USA HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps 6,7,8 Hydraulic Schematics (Open Circuit) GOLD CUP® Series - Open & Closed Circuits

3/8"-16 UNC-2A x 1/2" SOC. SETSCREW Series 6, 7 & 8 Information INSTALLED ONLY IF PORT "G" CONNECTS EXTERNALLY TO PORT "H".

PORT "H". INSTALL 1/8" PLUG IN PORT "H"

PACKAGE PUMP

C G D1

D2 H DG CONTROL FB OPTIONS FA RECOMMENDED EXTERNAL FILTER THE MAXIMUM PRESSURE BG AG DROP IN THE FILTER CIRCUIT SHOULD NOT EXCEED 150 PSI UNDER COLD START CONDITIONS 1/2A PLUG ON FACE OF PORT BLOCK

A 1/2A

K

2A 2A

A A

BVB KGV VA A

RECOMMENDED OPEN CIRCUIT PUMP CHECK VALVE pump rotary servo input port port rotation shaft rotation “A” “B” input command “A” side R CW inlet outlet L CCW inlet outlet input command “B” side R CCW inlet outlet L CW inlet outlet

NOTES:

1. The auxiliary pump inlet must be connected directly to the reservoir. See page 55 for main pump and auxiliary pump inlet requirements.

2. Case pressure must not exceed inlet pressure by more than 25 psi, 1,7 bar.

3. Maximum allowable inlet (port C) pressure: 200 psi, 13,8 bar.

4. Filters must use bypass valves.

5. Absolute inlet pressure must be increased for the following fluids: a. 25% for water glycols b. 35% for phosphate esters

6. A check valve in the outlet line between the pump and load is highly recommended where hoses, accumulators or other components may decompress when pump is vented by the compensator.

Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA 75 HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps 11,14 Hydraulic Schematics (Open Circuit) GOLD CUP® Series - Open & Closed Circuits

Series 11 & 14 Information

PACKAGE PUMP

C G D1

D2

DG CONTROL FB OPTIONS FA

BG

1/2A

A 1/2A

K

2A 2A

BG2 A A AG2

BVB KGV VA A

RECOMMENDED CHECK VALVE OPEN CIRCUIT PUMP

pump rotary servo input port port rotation shaft rotation “A” “B” input command “A” side R CW inlet outlet L CCW inlet outlet input command “B” side R CCW inlet outlet L CW inlet outlet

NOTES:

1. The auxiliary pump inlet must be connected directly to the reservoir. See page 55 for main pump and auxiliary pump inlet requirements.

2. Case pressure must not exceed inlet pressure by more than 25 psi, 1,7 bar.

3. Maximum allowable inlet (port C) pressure: 200 psi, 13,8 bar.

4. Filters must use bypass valves.

5. Absolute inlet pressure must be increased for the following fluids: a. 25% for water glycols b. 35% for phosphate esters

6. A check valve in the outlet line between the pump and load is highly recommended where hoses, accumulators or other components may decompress when pump is vented by the compensator.

Parker Hannifin Corporation Hydraulic Pump Division 76 Marysville, Ohio USA HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps GOLD CUP® Pump Control Combinations GOLD CUP® Series - Open & Closed Circuits

GOLD CUP® PUMP CONTROL COMBINATIONS 102 2M2 *00 2N2 *00 402 5A2 *00 7D6 *00 8A2 *00 8C2 *00 9A2 *00 104 2M2 *01 2N2 *01 404 5A2 *01 7D6 *01 8A2 *01 8C2 *01 9A2 *01 106 2M2 *02 2N2 *02 406 8A2 *02 8C2 *02 2M2 *03 2N2 *03 5A4 *00 8A2 *03 8C2 *03 9A4 *00 108 2M2 *04 2N2 *04 408 5A4 *01 8A2 *04 9A4 *01 2M2 *05 2N2 *05 8C4 *00 2A2 2M2 *06 2N2 *06 4A2 5A6 *00 7D8 *00 8A4 *00 8C4 *01 9A6 *00 2A4 2M2 *07 2N2 *07 4A4 5A6 *01 7D8 *01 8A4 *01 8C4 *02 9A6 *01 2A6 4A6 8A4 *02 8C4 *03 2M4 *00 2N4 *00 7F6 *01 8A4 *03 9A7*00 2A8 2M4 *01 2N4 *01 4A8 8A4 *04 8C6 *00 2M4 *02 2N4 *02 7F8 *01 8C6 *01 2H2 2M4 *03 2N4 *03 4B2 5A8 *00 8A6 *00 8C6 *02 9A8 *00 2H4 2M4 *04 2N4 *04 4B4 5A8 *01 7J6 *00 8A6 *01 8C6 *03 9A8 *01 2H6 2M4 *05 2N4 *05 4B6 7J6 *01 8A6 *02 2M4 *06 2N4 *06 5C2 *00 8A6 *03 9C2 *00 2H8 2M4 *07 2N4 *07 4B8 5C2 *01 8A6 *04 9C2 *01

2M6 *00 2N6 *00 4C2 5C4 *00 9C4 *00 2M6 *01 2N6 *01 4C4 5C4 *01 7J8 *00 9C4 *01 2M6 *02 2N6 *02 4C6 7J8 *01 8C8 *00 2M6 *03 2N6 *03 5C6 *00 8C8 *01 9C6 *00 2M6 *04 2N6 *04 4C8 5C6 *01 7K6 *01 8C8 *02 9C6 *01 2M6 *05 2N6 *05 8C8 *03 2M6 *06 2N6 *06 7K8 *01 8A8 *00 2M6 *07 2N6 *07 8A8 *01 8A8 *02 5C8 *00 8A8 *03 9C8 *00 5C8 *01 8A8 *04 9C8 *01

s5NLESSOTHERWISESPECIFIEDONPURCHASEORDER THEFOLLOWING factory setting will be used.

Maximum Stops: Full Displacement (both sides of center pumps) Minimum Stop: Zero Displacement (“V” units & 2A controls only) 2M8 *00 2N8 *00 Pressure Compensator Override: 1000 psi nominal 2M8 *01 2N8 *01 Torque Limiter (**4): P6 @ 1800 rpm = 60 hp nominal 2M8 *02 2N8 *02 (40% of full torque) P7 @ 1800 rpm = 72.5 hp nominal P8 @ 1800 rpm = 80 hp nominal 2M8 *03 2N8 *03 P11 @ 1800 rpm = 110 hp nominal 2M8 *04 2N8 *04 P14 @ 1800 rpm = 140 hp nominal 2M8 *05 2N8 *05 P24 @ 1800 rpm = 240 hp nominal P30 @ 1800 rpm = 300 hp nominal 2M8 *06 2N8 *06 2M8 *07 2N8 *07

Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA 77 HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps Pump Ordering Code GOLD CUP® Series - Open & Closed Circuits

P

Pump Displacement Type Efficiency Shaft Rotation Seals Design 2 Primary Secondary Control Controls Controls Location

Code Displacement Code Rotation Code Secondary Controls 6 6.00 in3/rev (98 cc/rev) R Clockwise Omit None (Fixed Displacement only) 7 7.25 in3/rev (119 cc/rev) L Counterclockwise 2 Volume Indicator 3 Torque Limiter & Volume 8 8.00 in /rev (131 cc/rev) 4 Code Seals Indicator 11 11.0 in3/rev (180 cc/rev) Cam Position Feedback 1 Nitrile (Buna-N) 6 14 14.0 in3/rev (229 cc/rev) Potentiometer 1 4 EPR 1, 3 Cam Position Feedback 24 24.6 in3/rev (403 cc/rev) 7 RVDT (AC)1 5 Fluorocarbon 30 30.6 in3/rev (501 cc/rev) Cam Position Feedback 8 R VDT (DC) 1 Code Primary Controls Code Type Omit None (Fixed Displacement only) Code Control Location F Fixed Displacement, Open/Closed Circuit Screw Adjustment (Spring Offset to Omit None (Fixed Displacement only) Fixed Displacement with High Torque 10 M Maximum Displacement) Thru-Drive, Open/Closed Circuit A Primary Control on Port A Side Cylinder Control w/Adjustable P Variable Displacement, Closed Circuit 2A B Primary Control on Port B Side Maximum Volume Stops Variable Displacement with Medium X Cylinder Control – 3-Position (Spring Torque Thru-Drive, Closed Circuit 2H Control with Zero Adjustment) 1 Not ATEX approved. Variable Displacement with Medium Cylinder Control – 2-Position Elec- 2 Assigned by manufacturer S Torque Thru-Drive & Shuttle Pack- trohydraulic w/Adjustable Maximum 3 Not available when using “5A” or age, Closed Circuit 2M Volume Stop (Spring Offset to “5C” primary controls. Pump will Variable Displacement with High Maximum Displacement) 1 be unpainted unless otherwise R Torque Thru-Drive, Closed Circuit specified. Cylinder Control – 3-Position 2N Variable Displacement with High (Spring Centered) Electrohydraulic 1 L Torque Thru-Drive & Shuttle Pack- 40 Rotary Servo – Spring Centered age, Closed Circuit Rotary Servo – Spring Centered w/ = Omit if not required Variable Displacement, Open Circuit 4A V Adjustable Maximum Volume Stops (P6, 7, 8, 11 & 14 only) Rotary Servo – Spring Centered w/ Variable Displacement, Open & 4B D Automatic Brake Control Closed Circuit (P6, 7 & 8 only) Rotary Servo – Spring centered w/

Code Efficiency 4C Adjustable Maximum Volume Stops & Automatic Brake Control H High Efficiency (P24 only) Electrohydraulic Stroker w/Adjust- 5A Omit Standard Efficiency able Maximum Volume Stops 1 Electrhydraulic Stroker w/Adjust- Code Shaft 5C able Maximum Volume Stops & Automatic Brake Control 1 Keyed SAE – Mechanical Shaft Seal 2 High IQ with 10 GPM Servo Valve (Single Lip Seal on P6, 7, 8F/M) 7D & Volume Indicator 1 Splined SAE – Mechanical Shaft Seal 3 High IQ with 10 GPM Servovalve (Single Lip Seal on P6, 7, 8F/M) 7F & 4A (Rotary Servo) Control 1 Keyed SAE-D (Mounting & Shaft) – Mechanical Shaft Seal (P6, 7 & High IQ with DF+ Valve & Volume 4 7J 8 only, Single Lip Seal on Fixed Indicator 1 Displacement Pumps) High IQ with DF+ Valve & 4A 7K Splined SAE-D (Mounting & Shaft) – (Rotary Servo) Control 1 Mechanical Shaft Seal (P6, 7 & -5 Hydraulic Stroker w/Adjustable 8 only, Single Lip Seal on Fixed 8A Maximum Volume Stops Displacement Pumps) Hydraulic Stroker w/Adjustable 7 Keyed SAE – Double Lip Shaft Seal 8C Maximum Volume Stops & Auto- 8 Splined SAE – Double Lip Shaft Seal matic Brake Control Keyed (long) SAE – Double Lip Electrohydraulic Stroker w/Adjust- 9 9A Shaft Seal able Maximum Volume Stops 1 Keyed (long) SAE – Mechanical Electrohydraulic Stroker w/Adjust- 10 Shaft Seal 9C able Maximum Volume Stops & Automatic Brake Control 1 Electro-hydraulic stroker w/ 9D Parker Hannifin Corporation adjustable maximum volume stops Hydraulic Pump Division 78 Marysville, Ohio USA HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps Pump Ordering Code GOLD CUP® Series - Open & Closed Circuits

Control & Internal External External Special Displacement Features Pump Drive Mounting Modifications

Control Code Control & Displacement Features Code Internal Pump 1.07 in3/rev (17.5 cc/rev) – P6, 7, 8P/S/X/V/D & P11, 14V only CETOP3, NG6 Valve, 110AC/60Hz with Hirschmann 00 0 2.14 in3/rev (35 cc/rev) – P11, 14P/S/X only Connector 1 2.81 in3/rev (46 cc.rev) – P24, 30P/S/X only (standard) CETOP3, NG6 Valve, 12VDC with Hirschmann 1.61 in3/rev (26.4 cc/rev) – P24, 30P/S/X only 01 1 1 Connector (auxiliary external replenishing flow required) CETOP3, NG6 Valve, 240VAC/50Hz with 1.05 in3/rev (17.2 cc/rev) – P24, 30P/S/X only 02 2 Hirschmann Connector 1 (auxiliary external replenishing flow required)

3 2M* & 03 CETOP3, NG6 Valve, 110VAC/60Hz, Wiring Box 1 3 3.56 in /rev (58.3 cc/rev) – P24, 30P/S/X only 2N* 4 4.84 in3/rev (79.3 cc/rev) – P24, 30P/S/X only 04 CETOP3, NG6 Valve, 12VDC, Wiring Box 1 5 5.42 in3/rev (88.8 cc/rev) – P24, 30P/S/X only 05 CETOP3 (D03, NG6) Interface, No Valve 1 6 6.10 in3/rev (100.0 cc/rev) – P24, 30P/S/X only CETOP3, NG6 Valve, 24VDC with Hirschmann 06 Connector 1 X No Internal Pump (standard on P*R/L/F/M) CETOP3, NG6 Valve, 110VAC/50Hz with 07 Code External Drive Hirschmann Connector 1 Omit None 1 00 With Deadband 1 5** M Blanking plate – for P6, 7, 8, 11, 14S/X only Without Deadband 1 01 A SAE-A (SAE 82-2) – P6, 7, 8, 11, 14S/X/R/L/M only 00 Without Manual Override Shutoff 1 SAE-B (SAE 101-2) – P6, 7, 8, 11, 14, 24, 30/S/X/R/L/M B SAE-B (SAE 101-4) – P11, 14, 24, 30R/L/M 7** With Manual Override Shutoff 1 01 SAE-C (SAE 127-2) – P6, 7, 8, 11, 14, 24, 30R/L/M & P24, (required for F & K primary options) C 30S/X SAE-C (SAE 127-4) – P11, 14, 24, 30R/L/M 00 75-350 PSI (5-24 Bar) D SAE-D (SAE 152-4) – P11, 14, 24, 30R/L/M only 75-435 PSI (5-30 Bar) 01 E SAE-E (SAE 165-4) – P11, 14, 24, 30R/L/M only 8** 02 100-380 PSI (7-26 Bar) F SAE-F (SAE 177-4) – P24, 30R/L/M only 03 150-400 PSI (10-28 Bar) Code External Mounting 04 75-250 PSI (5-17 Bar) Omit No External Drive Required

00 24VDC 9** 0 No External Pump Mounted 01 12VDC External Pump Mounted (must be separately specified) – 1 Requires Special Modification “-M2” 1 All 00 None 1 Other 2 ATEX Externally Mounted Pump Pump Code Reduced Displacement Code Special Modifications 00 Standard Cam (19°) Omit None 3 P6 with 17° Cam – 5.3 in /rev (87cc/rev) NP No Paint 1 P7 with 17° Cam – 6.4 in3/rec (105 cc/rev) 3 ATEX APPROVED PUMP (May contain additional P8 with 17° Cam – 7.1 in /rev (116 cc/rev) EX 10 P11 with 17° Cam – 9.7 in3/rev (160 cc/rev) modifications. Contact tech support.) P14 with 17° Cam – 12.5 in3/rev (205 cc/rev) Other Special Modification (example: bronze caged barrel 3 M2 P24 with 17° Cam – 22.0 in /rev (360 cc/rev) bearing for low viscosity fluids, tandem pumps, etc.) 1 P**F P30 with 17° Cam – 27.2 in3/rev (446 cc/rev) & P**M P6 with 15° Cam – 4.6 in3/rev (76 cc/rev) P7 with 15° Cam – 5.6 in3/rev (92 cc/rev) 20 P8 with 15° Cam – 6.2 in3/rev (102 cc/rev) P11 with 15° Cam – 8.5 in3/rev (140 cc/rev) P14 with 15° Cam – 10.9 in3/rev (179 cc/rev) P6 with 13° Cam – 4.0 in3/rev (66 cc/rev) 30 P7 with 13° Cam – 4.8 in3/rev (79 cc/rev) P8 with 13° Cam – 5.3 in3/rev (88 cc/rev)

= Omit if not required

Parker Hannifin Corporation Hydraulic Pump Division 78 Marysville, Ohio USA 79 HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps Notes GOLD CUP® Series - Open & Closed Circuits Notes

Parker Hannifin Corporation Hydraulic Pump Division 80 Marysville, Ohio USA HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps GOLD CUP® Motor Control Combinations GOLD CUP® Series - Open & Closed Circuits

GOLD CUP® MOTOR CONTROL COMBINATIONS 2A0 *2M3 *0 5A0 *0 8A0 *0 9A0 *0 *2A3 *2M3 *1 5A0 *1 8A0 *1 9A0 *1 *2A5 *2M3 *2 2A6 *2M3 *3 5A3 *0 8A3 *0 9A3 *0 *2M3 *4 5A3 *1 8A3 *1 9A3 *1 2A8 *2M3 *5 *2M3 *6 5A5 *0 8A5 *0 9A5 *0 2M0 *0 5A5 *1 8A5 *1 9A5 *1 2M0 *1 2M0 *2 *2M5 *0 5A6 *0 8A6 *0 9A6 *0 2M0 *3 *2M5 *1 5A6 *1 8A6 *1 9A6 *1 2M0 *4 *2M5 *2 2M0 *5 *2M5 *3 2M0 *6 *2M5 *4 *2M5 *5 *2M5 *6 5A8 *0 8A8 *0 9A8 *0 5A8 *1 8A8 *1 9A8 *1

*2M6 *0 9D0*0 *2M6 *1 9D081 *2M6 *2 *2M6 *3 *2M6 *4 *2M6 *5 *2M6 *6

s.OTAVAILABLEFOR-OR-

Unless otherwise specified on purchase order, the following factory setting will be used. Maximum Stop: Full Displacement *2M8 *0 Minimum Stop: Approximately 30% Displacement *2M8 *1 Reverse Pressure Compensator Override (**3 & **5): 1000 psi *2M8 *2 nominal *2M8 *3 *2M8 *4 *2M8 *5 *2M8 *6

Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA 81 HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps Motor Ordering Code GOLD CUP® Series - Open & Closed Circuits

M N

Motor Displacement Type Efficiency Shaft Bi-directional Seals Design 2 Primary Secondary Control Rotation Controls Controls Location

Code Displacement Code Seals 6 6.00 in3/rev (98cc/rev) 1 Nitrile (Buna-N) 7 7.25 in3/rev (119 cc/rev) 4 EPR 3 8 8.00 in3/rev (131 cc/rev) 5 Fluorocarbon 11 11.0 in3/rev (180 cc/rev) Code Primary Controls 14 14.0 in3/rev (229 cc/rev) Omit None (Fixed Displacement only) 24 24.6 in3/rev (403 cc/rev) Cylinder Control w/Adjustable 3 2A 30 30.6 in /rev (501 cc/rev) Maximum Volume Stops Cylinder Control – 2-Position Code Type 2M Electrohydraulic w/Adjustable Maximum Volume Stop (Spring F Fixed Displacement Offset to Maximum Displacement)1 Fixed Displacement with Electrohydraulic Stroker w/ G 5A Shuttle Package Adjustable Maximum Volume Stops1 Fixed Displacement with 8A Hydraulic Stroker w/Adjustable Maximum Volume Stops M Thru-Drive Electrohydraulic Stroker w/ 9A Fixed Displacement with Adjustable Maximum Volume Stops1 N Thru-Drive & Shuttle Package V Variable Displacement Code Secondary Controls Variable Displacement with Omit None (Fixed Displacement only) H Shuttle Package 0 Volume Indicator Variable Displacement with R Reverse Compensator (spring offset to Thru-Drive 3 maximum displacement) + Volume Indicator Variable Displacement with L Reverse Compensator (spring offset to Thru-Drive & Shuttle Package 5 minimum displacement) + Volume Indicator 6 Cam Position Feedback Potentiometer1 Code Efficiency 7 Cam Position Feedback RVDT (AC)1 H High Efficiency (M24 only) 8 Cam Position Feedback RVDT (DC)1 Omit Standard Efficiency Reverse Compensator (3) + Cam Position U Feedback Potentiometer (6)1 Code Shaft Reverse Compensator (3) + Cam Position Keyed SAE – Mechanical Shaft Seal W 2 Feedback RVDT (8)1 (Single Lip Seal on M6, 7, 8F/G/M/N) Reverse Compensator (5) + Cam Position Splined SAE – Mechanical Shaft Seal X 3 Feedback Potentiometer (6)1 (Single Lip Seal on M6, 7, 8F/G/M/N) Reverse Compensator (5) + Cam Position Z Keyed SAE-D (Mounting & Shaft) – Feedback RVDT (8)1 4 Mechanical Shaft Seal (M6, 7 & 8 only, Single Lip Seal on Fixed Displacement Motors) Code Control Location Splined SAE-D (Mounting & Shaft) – 5 Mechanical Shaft Seal (P6, 7 & 8 only, Omit None (Fixed Displacement only) Single Lip Seal on Fixed Displacement Motors) A Primary Control on Port A Side 7 Keyed SAE – Double Lip Shaft Seal B Primary Control on Port B Side Splined SAE – Double Lip 8 Shaft Seal 9 Keyed (long) SAE – Double Lip Shaft Seal = Omit if not required 10 Keyed (long) SAE – Mechanical Shaft Seal

1 Not ATEX approved. 2 Assigned by manufacturer. 3 Not available when using “5A” primary control. Motor will be unpainted unless otherwise specified.

Parker Hannifin Corporation Hydraulic Pump Division 82 Marysville, Ohio USA HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps Motor Ordering Code GOLD CUP® Series - Open & Closed Circuits

Control & Shuttle Valve External External Special Displacement Features Features Drive Mounting Modifications

Control Code Control & Displacement Features Code Shuttle Valve Features CETOP3, NG6 Valve, 110AC/60Hz with Omit M*F/M/V/R Motors only 0 1 Hirschmann Connector 0 Without Orifices CETOP3, NG6 Valve, 12VDC with Hirschmann 1 2 With Orifices Connector1 CETOP3, NG6 Valve, 240VAC/50Hz with 2 Code External Drive Hirschmann Connector1 Omit None (M*F/G/V/H units only) CETOP3, NG6 Valve, 110VAC/60Hz, 3 A SAE-A (SAE 82-2) – M6, 7, 8, 11, 14M/N/R/L only 2M Wiring Box1 SAE-B (SAE 101-2) – M6, 7, 8M/N/R/L B 4 CETOP3, NG6 Valve, 12VDC, Wiring Box1 SAE-B (SAE 101-2 & 101-4) – M11, 14, 24, 30M/N/R/L 1 SAE-C (SAE 127-2) – M6, 7, 8M/N/R/L 5 CETOP3 (D03, NG6) Interface, No Valve C SAE-C (SAE 127-2 & 127-4) – M11, 14, 24, 30M/N/R/L CETOP3, NG6 Valve, 24VDC with Hirschmann 6 Connector1 D SAE-D (SAE 152-4) – M11, 14, 24, 30M/N/R/L only E SAE-E (SAE 165-4) – M11, 14, 24, 30M/N/R/L only CETOP3, NG6 Valve, 110VAC/50Hz with 7 Hirschmann Connector1 F SAE-F (SAE 177-4) – M24, 30M/N/R/L only 0 With Deadband1 M Blanking Plate-less Coupling 5A 1 Without Deadband1 Code External Mounting 0 75-250 PSI (5-17 Bar) 0 No External Motor Mounted 8A 1 250-450 PSI (17-31 Bar) External Motor Mounted (must be separately specified) – 1 Requires Special Modification “-M2” 0 24VDC1 9A 2 ATEX Externally Mounted Motor 1 12VDC1 All Other 0 None Code Special Modifications Omit None Motor Code Reduced Displacement NP No Paint 0 Standard Cam (19°) Other Special Modification (example: bronze caged barrel M2 M6 with 17° Cam – 5.3 in3/rev (87cc/rev) bearing for low viscosity fluids, tandem motors, etc.) M7 with 17° Cam – 6.4 in3/rec (105 cc/rev) ATEX APPROVED (May contain additional modifications. M8 with 17° Cam – 7.1 in3/rev (116 cc/rev) EX Contact tech support.) 1 M11 with 17° Cam – 9.7 in3/rev (160 cc/rev) M14 with 17° Cam – 12.5 in3/rev (205 cc/rev) 3 M*F M24 with 17° Cam – 22.0 in /rev (360 cc/rev) 3 M*G M30 with 17° Cam – 27.2 in /rev (446 cc/rev) M*M M6 with 15° Cam – 4.6 in3/rev (76 cc/rev) M*N M7 with 15° Cam – 5.6 in3/rev (92 cc/rev) 2 M8 with 15° Cam – 6.2 in3/rev (102 cc/rev) M11 with 15° Cam – 8.5 in3/rev (140 cc/rev) M14 with 15° Cam – 10.9 in3/rev (179 cc/rev) M6 with 13° Cam – 4.0 in3/rev (66 cc/rev) 3 M7 with 13° Cam – 4.8 in3/rev (79 cc/rev) M8 with 13° Cam – 5.3 in3/rev (88 cc/rev)

= Omit if not required

Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA 83 HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps Notes GOLD CUP® Series - Open & Closed Circuits Notes

Parker Hannifin Corporation Hydraulic Pump Division 84 Marysville, Ohio USA HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps Notes GOLD CUP® Series - Open & Closed Circuits Notes

Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA 85 HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps Notes GOLD CUP® Series - Open & Closed Circuits Notes

Parker Hannifin Corporation Hydraulic Pump Division 86 Marysville, Ohio USA HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps Offer of Sale GOLD CUP® Series - Open & Closed Circuits

The items described in this document and other documents and descriptions provided by Parker Hannifin Corporation, Hydraulics Group, and its authorized distributors (“Seller”) are hereby offered for sale at prices to be established by Seller. This offer and its acceptance by any customer (“Buyer”) shall be governed by all of the following Terms and Conditions. Buyer’s order for any item described in its document, when communicated to Seller verbally, or in writing, shall constitute acceptance of this offer. All goods or work described will be referred to as “Products”.

1. Terms and Conditions. Seller’s willingness to offer Products, or accept an order for 11. Buyer’s Obligation; Rights of Seller. To secure payment of all sums due or otherwise, Products, to or from Buyer is expressly conditioned on Buyer’s assent to these Terms and Seller shall retain a security interest in the goods delivered and this agreement shall be Conditions and to the terms and conditions found on-line at www.parker.com/saleterms/. deemed a Security Agreement under the Uniform Commercial Code. Buyer authorizes Seller objects to any contrary or additional term or condition of Buyer’s order or any other Seller as its attorney to execute and file on Buyer’s behalf all documents Seller deems document issued by Buyer. necessary to perfect its security interest. Seller shall have a security interest in, and lien 2. Price Adjustments; Payments. Prices stated on the reverse side or preceding pages upon, any property of Buyer in Seller’s possession as security for the payment of any of this document are valid for 30 days. After 30 days, Seller may change prices to reflect any amounts owed to Seller by Buyer. increase in its costs resulting from state, federal or local legislation, price increases from its 12. Improper Use and Indemnity. Buyer shall indemnify, defend, and hold Seller harmless suppliers, or any change in the rate, charge, or classification of any carrier. The prices stated from any claim, liability, damages, lawsuits, and costs (including attorney fees), whether for on the reverse or preceding pages of this document do not include any sales, use, or other personal injury, property damage, patent, trademark or copyright infringement or any other taxes unless so stated specifically. Unless otherwise specified by Seller, all prices are F.O.B. claim, brought by or incurred by Buyer, Buyer’s employees, or any other person, arising out Seller’s facility, and payment is due 30 days from the date of invoice. After 30 days, Buyer of: (a) improper selection, improper application or other misuse of Products purchased by shall pay interest on any unpaid invoices at the rate of 1.5% per month or the maximum Buyer from Seller; (b) any act or omission, negligent or otherwise, of Buyer; (c) Seller’s use allowable rate under applicable law. of patterns, plans, drawings, or specifications furnished by Buyer to manufacture Product; 3. Delivery Dates; Title and Risk; Shipment. All delivery dates are approximate and or (d) Buyer’s failure to comply with these terms and conditions. Seller shall not indemnify Seller shall not be responsible for any damages resulting from any delay. Regardless of the Buyer under any circumstance except as otherwise provided. manner of shipment, title to any products and risk of loss or damage shall pass to Buyer 13. Cancellations and Changes. Orders shall not be subject to cancellation or change by upon tender to the carrier at Seller’s facility (i.e., when it’s on the truck, it’s yours). Unless Buyer for any reason, except with Seller’s written consent and upon terms that will indemnify, otherwise stated, Seller may exercise its judgment in choosing the carrier and means of defend and hold Seller harmless against all direct, incidental and consequential loss or delivery. No deferment of shipment at Buyers’ request beyond the respective dates indicated damage. Seller may change product features, specifications, designs and availability with will be made except on terms that will indemnify, defend and hold Seller harmless against notice to Buyer. all loss and additional expense. Buyer shall be responsible for any additional shipping 14. Limitation on Assignment. Buyer may not assign its rights or obligations under this charges incurred by Seller due to Buyer’s changes in shipping, product specifications or in agreement without the prior written consent of Seller. accordance with Section 13, herein. 15. Entire Agreement. This agreement contains the entire agreement between the Buyer 4. Warranty. Seller warrants that the Products sold hereunder shall be free from defects in and Seller and constitutes the final, complete and exclusive expression of the terms of the material or workmanship for a period of eighteen months from the date of delivery to Buyer. agreement. All prior or contemporaneous written or oral agreements or negotiations with The prices charged for Seller’s products are based upon the exclusive limited warranty respect to the subject matter are herein merged. stated above, and upon the following disclaimer: DISCLAIMER OF WARRANTY: THIS 16. Waiver and Severability. Failure to enforce any provision of this agreement will not WARRANTY COMPRISES THE SOLE AND ENTIRE WARRANTY PERTAINING TO waive that provision nor will any such failure prejudice Seller’s right to enforce that provision PRODUCTS PROVIDED HEREUNDER. SELLER DISCLAIMS ALL OTHER WARRAN- in the future. Invalidation of any provision of this agreement by legislation or other rule of law TIES, EXPRESS AND IMPLIED, INCLUDING MERCHANTABILITY AND FITNESS FOR shall not invalidate any other provision herein. The remaining provisions of this agreement A PARTICULAR PURPOSE. will remain in full force and effect. 5. Claims; Commencement of Actions. Buyer shall promptly inspect all Products upon 17. Termination. This agreement may be terminated by Seller for any reason and at any delivery. No claims for shortages will be allowed unless reported to the Seller within 10 days time by giving Buyer thirty (30) days written notice of termination. In addition, Seller may by of delivery. No other claims against Seller will be allowed unless asserted in writing within written notice immediately terminate this agreement for the following: (a) Buyer commits a 60 days after delivery or, in the case of an alleged breach of warranty, within 30 days after breach of any provision of this agreement (b) the appointment of a trustee, receiver or custo- the date within the warranty period on which the defect is or should have been discovered dian for all or any part of Buyer’s property (c) the filing of a petition for relief in bankruptcy by Buyer. Any action based upon breach of this agreement or upon any other claim arising of the other Party on its own behalf, or by a third party (d) an assignment for the benefit of out of this sale (other than an action by Seller for any amount due to Seller from Buyer) must creditors, or (e) the dissolution or liquidation of the Buyer. be commenced within thirteen months from the date of tender of delivery by Seller or, for 18. Governing Law. This agreement and the sale and delivery of all Products hereunder a cause of action based upon an alleged breach of warranty, within thirteen months from shall be deemed to have taken place in and shall be governed and construed in accordance the date within the warranty period on which the defect is or should have been discovered with the laws of the State of Ohio, as applicable to contracts executed and wholly performed by Buyer. therein and without regard to conflicts of laws principles. Buyer irrevocably agrees and 6. LIMITATION OF LIABILITY. UPON NOTIFICATION, SELLER WILL, AT ITS OPTION, consents to the exclusive jurisdiction and venue of the courts of Cuyahoga County, Ohio REPAIR OR REPLACE A DEFECTIVE PRODUCT, OR REFUND THE PURCHASE with respect to any dispute, controversy or claim arising out of or relating to this agreement. PRICE. IN NO EVENT SHALL SELLER BE LIABLE TO BUYER FOR ANY SPECIAL, Disputes between the parties shall not be settled by arbitration unless, after a dispute has INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF, OR AS arisen, both parties expressly agree in writing to arbitrate the dispute. THE RESULT OF, THE SALE, DELIVERY, NON-DELIVERY, SERVICING, USE OR LOSS 19. Indemnity for Infringement of Intellectual Property Rights. Seller shall have no OF USE OF THE PRODUCTS OR ANY PART THEREOF, OR FOR ANY CHARGES OR liability for infringement of any patents, trademarks, copyrights, trade dress, trade secrets EXPENSES OF ANY NATURE INCURRED WITHOUT SELLER’S WRITTEN CONSENT, or similar rights except as provided in this Section. Seller will defend and indemnify Buyer EVEN IF SELLER HAS BEEN NEGLIGENT, WHETHER IN CONTRACT, TORT OR against allegations of infringement of U.S. patents, U.S. trademarks, copyrights, trade dress OTHER LEGAL THEORY. IN NO EVENT SHALL SELLER’S LIABILITY UNDER ANY and trade secrets (“Intellectual Property Rights”). Seller will defend at its expense and will CLAIM MADE BY BUYER EXCEED THE PURCHASE PRICE OF THE PRODUCTS. pay the cost of any settlement or damages awarded in an action brought against Buyer 7. Contingencies. Seller shall not be liable for any default or delay in performance if based on an allegation that a Product sold pursuant to this Agreement infringes the Intel- caused by circumstances beyond the reasonable control of Seller. lectual Property Rights of a third party. Seller’s obligation to defend and indemnify Buyer 8. User Responsibility. The user, through its own analysis and testing, is solely responsible is contingent on Buyer notifying Seller within ten (10) days after Buyer becomes aware of for making the final selection of the system and Product and assuring that all performance, such allegations of infringement, and Seller having sole control over the defense of any endurance, maintenance, safety and warning requirements of the application are met. The allegations or actions including all negotiations for settlement or compromise. If a Product is user must analyze all aspects of the application and follow applicable industry standards and subject to a claim that it infringes the Intellectual Property Rights of a third party, Seller may, Product information. If Seller provides Product or system options, the user is responsible for at its sole expense and option, procure for Buyer the right to continue using the Product, determining that such data and specifications are suitable and sufficient for all applications replace or modify the Product so as to make it noninfringing, or offer to accept return of and reasonably foreseeable uses of the Products or systems. the Product and return the purchase price less a reasonable allowance for depreciation. 9. Loss to Buyer’s Property. Any designs, tools, patterns, materials, drawings, confiden- Notwithstanding the foregoing, Seller shall have no liability for claims of infringement based tial information or equipment furnished by Buyer or any other items which become Buyer’s on information provided by Buyer, or directed to Products delivered hereunder for which property, may be considered obsolete and may be destroyed by Seller after two consecutive the designs are specified in whole or part by Buyer, or infringements resulting from the years have elapsed without Buyer placing an order for the items which are manufactured modification, combination or use in a system of any Product sold hereunder. The foregoing using such property. Seller shall not be responsible for any loss or damage to such property provisions of this Section shall constitute Seller’s sole and exclusive liability and Buyer’s sole while it is in Seller’s possession or control. and exclusive remedy for infringement of Intellectual Property Rights. 10. Special Tooling. A tooling charge may be imposed for any special tooling, including 20. Taxes. Unless otherwise indicated, all prices and charges are exclusive of excise, sales, without limitation, dies, fixtures, molds and patterns, acquired to manufacture Products. use, property, occupational or like taxes which may be imposed by any taxing authority upon Such special tooling shall be and remain Seller’s property notwithstanding payment of any the manufacture, sale or delivery of Products. charges by Buyer. In no event will Buyer acquire any interest in apparatus belonging to 21. Equal Opportunity Clause. For the performance of government contracts and where Seller which is utilized in the manufacture of the Products, even if such apparatus has been dollar value of the Products exceed $10,000, the equal employment opportunity clauses in specially converted or adapted for such manufacture and notwithstanding any charges paid Executive Order 11246, VEVRAA, and 41 C.F.R. §§ 60-1.4(a), 60-741.5(a), and 60-250.4, by Buyer. Unless otherwise agreed, Seller shall have the right to alter, discard or otherwise are hereby incorporated. dispose of any special tooling or other property in its sole discretion at any time.

Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA 87 North America Truck The Netherlands Korea USA Oldenzaal Seoul Industrial Tel: (31) 541 585000 Tel: (82) 2 559 0400 USA Eastern Region Chicago Region Cleveland, OH Norway Malaysia Naperville, IL Tel: (440) 519 1125 Ski Subang Jaya Tel: (630) 964 0796 Western Region Tel: (47) 64 91 10 00 Tel: (60) 3 5638 1476 Great Lakes Region San Ramon, CA Poland New Zealand Fairlawn, OH Tel: (925) 735 9573 Warsaw Mt. Wellington Tel: (330) 670 2680 Canada Tel: (48) 22 57 32400 Tel: (64) 9 574 1744 Northeast Region Milton, Ontario Japan Lebanon, NJ Tel: (905) 693 3000 Tel: (908) 236 4121 Leca da Palmeira Tokyo México Tel: (351) 22 999 7360 Tel: (81) 3 6408 3900 Pacific Region Apodaca, N.L. Romania Singapore Buena Park, CA Tel: (52) 81 8156 6000 Tel: (714) 228 2509 Bucharest Jurong Town Tel: (40) 21 252 1382 Tel: (65) 6 887 6300 Southern Region Russia Alpharetta, GA Austria Taiwan Tel: (770) 619 9767 Moscow Taipei Wiener Neustadt Tel: (7) 495 580 9145 Canada Tel: (43) 2622 23501 0 Tel: (886) 2 2298 8987 Milton, Ontario Slovenia Belgium Novo Mesto Thailand Tel: (905) 693 3000 Bangkok Nivelles Tel: (386) 7 337 6650 México Tel: (32) 67 280 900 Tel: (662) 717 8140 Toluca, Edo. de México Czech Republic and Tel: (52) 72 2275 4200 Slovakia Madrid Middle East Klecany Tel: (34) 91 675 7300 United Arab Emirates Mobile Tel: (420) 284 083 111 Sweden Abu Dhabi USA Denmark Spanga Tel: (971) 2 678 8587 Global Mobile Ballerup Tel: (46) 8 597 95000 Lincolnshire, IL Tel: (45) 4356 0400 Ukraine Latin America Tel: (847) 821 1500 Finland Kiev Pan American Division Central Region Vantaa Tel: (380) 44 494 2731 Miami, FL Lincolnshire, IL Tel: (358) 20 753 2500 United Kingdom Tel: (305) 470 8800 Tel: (847) 821 1500 Warwick, Argentina Eastern Region Contamine-sur-Arve Tel: (44) 1926 317878 Buenos Aires North Canton, OH Tel: (33) 4 50 25 80 25 Tel: (54) 33 2744 4129 Tel: (330) 284 3355 Germany Asia Pacific Midwest Region Brazil Kaarst Australia Cachoeirinha RS Hiawatha, IA Tel: (49) 2131 4016 0 Tel: (319) 393 1221 Castle Hill Tel: (55) 51 3470 9144 Greece Tel: (61) 2 9634 7777 Southern Region Athens Venezuela Aledo, TX Tel: (30) 210 933 6450 China Caracas Tel: (817) 441 1794 Beijing Tel: (58) 212 238 5422 Hungary Western Region Tel: (86) 10 6561 0520 Buena Park, CA Budapest Shanghai Africa Tel: (36) 1 220 4155 Tel: (714) 228 2509 Tel: (86) 21 5031 2525 South Africa Canada Ireland Kempton Park County Dublin, Baldonnell Hong Kong Milton, Ontario Tel: (852) 2428 8008 Tel: (27) 11 961 0700 Tel: (905) 693 3000 Tel: (353) 1 466 6370 India México Mahape, Navi Mumbai Apodaca, N.L. Corsico, Milano Tel: (91) 22 5613 7081 Tel: (52) 81 8156 6000 Tel: (39) 02 45 19 21

© 2013 Parker Hannifin Corporation, all rights reserved This literature replaces ALL previous literature Web Only HY28-2667-01/GC/NA,EU Parker Hannifin Corporation Effective: June 01, 2013 Hydraulic Pump Division 14249 Industrial Parkway Marysville, OH 43040 USA phone 937.644.4532 fax 937.642.3639 www.parkerhpd.com