LAMBDA Gas Flare for the high temperature range

Inspection, Emergency and Endurance Burning Flares for gas, Sewage Gas, and Mine Gas

Standardised or customised plants for the treatment of gases containing

〉 For the treatment of gas quantities of 50-2,500 Nm³/h 〉 Suitable for minimum methane contents of 25 Vol.-% 〉 A version that is conform with the German Technical Instructions on Air Quality Control (TA-Luft) 〉 Modular design for an excellent price-performance ratio 〉 Prepared for automatic operation 〉 Stainless steel or painted steel versions 〉 Integrated gas pressure boosting (optional) 〉 Fully concealed

〉 Simple installation and commissioning LAMBDA Gesellschaft für Gastechnik mbH Hertener Mark 3 45699 Herten, Germany [email protected] www.lambda.de

LAMBDA This is where I am safe. LAMBDA Gas Flare Detached high temperature flare stack for biogenic gases with a methane content of between 25% and 65%

Turbulence line burner with a controlled natural draft air supply

The LAMBDA high temperature flare is used to burn methane The flare is controlled by means of a switch cabinet that can either gases that are formed in the landfill body as a result of anaerobic be mounted on the flare or separately, e.g. on a building. All of the processes, or other gases containing methane. signals can be made available for transmission to a superordinate process control system. The combustion takes place from the lower edge of the flare cover under a high quantity of surplus air and a minimum temperature of 1,000°C. The interior of the flare cover is lined with a ceramic fibre insulation that can be subjected to a maximum temperature of Benefits 1,430°C. The control that is required in order to achieve a constant 〉 Invisible flame combustion temperature is provided by means of air control 〉 Simple, robust design dampers. The air intake is ensured on the basis of the natural draft 〉 Fast installation air supply principle. The turbulence line burner ensures an intensive 〉 High output mixing of combustion air and the combustion gas so that the control 〉 Easy to control in the operating range temperature is already reached in the lower part of the flare cover. 〉 Full combustion due to an optimal mixing with surplus air This ensures an homogenous distribution of the temperature within the combustion space.

The flare is equipped with a gas control and safety line. These comprise the measuring devices such as the pressure measuring device and the safety organs, together with the quick-action valve.

TECHNICAL DATA Thermal output (kW) 250-12,000 Gas quantity (Nm3/h) 50-2,500 (with 50 Vol.-% methane) Control range 1 : 5 Methane content (%) approx. 25-65 Exhaust gas outlet height max. 10 m, greater heights upon request Operating temperature (°C) 1,000-1,200 Power consumption (kW) approx. 1-2 Dwell time according to TA-Luft > 0.3 s at 1,000°C

LAMBDA Gesellschaft für Gastechnik mbH Hertener Mark 3 45699 Herten, Germany [email protected]

Valid from May 2016, The right is reserved to make technical modifications that serve progress Valid www.lambda.de

LAMBDA This is where I am safe.