Volume 3, Section 4.2 | Controllers PFC200 XTR

Controller PFC200; 2 x , RS-232/-485, CAN, CANopen, Slave; Extreme connection Fieldbus connection PROFIBUS CAN, CANopen Serial interface

01 02 BF SYS RST A B DIA RUN C D U4 I/O X4 CAN 24V 0V X5 PROFIBUS X3 RS232/485 U3 MS U2 NS U1 CAN Supply voltage (system) ++ SD

— — X1 750-8206/040-00 0 ACT Supply voltage (ƒeld)

RUN X2 STOP RESET ACT LNK ETH LNK

Fieldbus connection SD memory card slot 2 x RJ-45

Figure: 750-8206/040-000 Item description Controller PFC200; 2 x ETHERNET, RS-232/-485, CAN, CANopen, PROFIBUS Slave Version Extreme Telecontrol technology; extreme 750-8206/040-000 750-8206/040-001 Item No. Order text PFC200; 2ETH RS CAN DPS; XTR PFC200; 2ETH RS CAN DPS; Tele; XTR 4.2 Technical Data Communication (TCP, UDP, RTU); EtherNet/IP adapter Modbus (TCP, UDP, RTU); MQTT; PROFIBUS; CAN; (slave)1); MQTT; PROFIBUS; CANopen; CANopen; Telecontrol protocols; RS-232/-485 interface RS-232/-485 interface ETHERNET protocols DHCP; DNS; NTP; FTP; FTPS; SNMP; HTTP; HTTPS; SSH Telecontrol protocols IEC 60870-5-101/-103/-104; IEC 61850-7-4; IEC 61400-25; DNP3 Visualization Web-Visu Programming WAGO-I/O-PRO V2.3 (based on CODESYS V2.3); WAGO-I/O-PRO V2.3 (based on CODESYS V2.3) e!COCKPIT (based on CODESYS V3) CPU Cortex A8; 600 MHz Operating system Real-time Linux (with RT-Preempt patch) Main memory (RAM)/internal memory (flash)/ 256 MB / 256 MB / 128 KB non-volatile memory (hardware) Program memory/data memory/non-volatile CODESYS V2: 16 MB / 64 MB / 128 KB memory (software) e!RUNTIME: 60 MB* / 60 MB* / 128 KB Number of modules per node (max.) 64 Input and output process image (internal) max. 1000 words Input and output process image (MODBUS)/ CODESYS V2: 1000 words / 244 bytes / 2000 words (PROFIBUS)/(CAN) max. e!RUNTIME: 32000 words / 244 bytes / 2000 words Supply voltage (system) 24 VDC (−25 … +30 %); via wiring level (CAGE CLAMP® connection); Specified values for surrounding air temperature: +15 … +35 °C; For −40 … +55 °C: 24 V (−25 … +20 %); For +55 … +70 °C: 24 V (−25 … +10 %); Lower limit in all temperature ranges: −27.5 % (including 15 % residual ripple) Supply voltage (field) 24 VDC; via power jumper contacts Input current (typ.) at nominal load (24 V) 550 mA Current consumption – system supply (5 V) 600 mA Total current (system supply) 1700 mA Surrounding air temperature (operation) −40 … +70 °C Dimensions W x H x D 112 x 71.9 x 100 mm Approvals 1; ; Marine; r OrdLoc/HazLoc; 4 ATEX/IECEx Data sheet and further information, see: wago.com/750-8206/040-000 wago.com/750-8206/040-001

Accessories Item No. Page 758-879/000-001 SD memory card; 2 GB 470

1)Library for e!RUNTIME *For memory configuration via e!RUNTIME, the program and data memory together have a maximum size of 60 MB and can be distributed dynamically.

Automation Technology 101