DSX Access Systems, Inc.

DSX-1044 Typical Connections

DSX-1044 Input Controller Typical Connections

S ERIAL #

DSX-1044 Intelligent Controller

P OWER 1 2 POLL 3 4 B UF FER 5 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 DOWN 6 A :9 A :11 Comm on A :13 A :15 Comm on B :9 B :11 Comm on B :13 B :15 Com LOAD 7 A:10 A:12 A:14 A:16 B:10 B:12 B:14 B:16

8 A LIVE

32 Input Board Input 32 DSX

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 - TX RX TX RX GND A :1 A :3 Comm on A :5 A :7 Comm on A :1 A :2B :1 B :2 B :1 B :3 Comm on B :5 B :7 Comm on+12V 1044 A :2 A :4 A :6 A :8 B :2 B :4 B :6 B :8 GND Open Open DC IN SUB PC - MA S TER Collectors Collectors

TO 1040CDM S EE TO 1040CDM CHARTS O F THIS PAGE 1000 FROM COM M ohm Switched Negati ve E .O.L.s S ERV ER Sources (-100ma) RS-232 PORT In put Req uirements In put Circu it Type 0 All Inputs of 1042, 1044, 1032, 1034, 1022, 1021 and 1020s

1000 1000ohm E.O.L. are Supervised Inputs and requi re E.O.L resistors in Circuit. ohm NC E.O.L.s are required on ALL supervised Inputs, Used, E .O.L. Unused, Defined or Undefined. NO

In put Circu it Type 1 820 In put Circuit Type Definitions 1000 Input Circuit Type 0 : NC or NO Sensors, No Trouble 1000ohm E.O.L. ohm In put Circu it Type 3 ohm NC NC E .O.L. NO Sensor Shorts = Alarm, NC Sensor Opens = Alarm E .O.L. 180 Input Circuit Type 1 : NC Sensors Only NC NC ohm NC Sensor Opens = Alarm, Circuit Shorts = T rouble E .O.L. Input Circuit Type 2 : NO Sensors O nly In put Circu it Type 2 820 NO Sensor Shorts = Alarm, Circuit Opens = Trouble 1000 ohm Input Circuit Type 3 : NC Sensors Only In put Circu it Type 4 ohm E .O.L. Sensor O pens = Alarm, Circuit Opens or Shorts = Trouble E .O.L. 180 Input Circuit Type 4 : NO Sensors O nly NO NO 1000 ohm Sensor Shorts = Al arm, Circuit O pens or Shorts = T rouble ohm E .O.L. SIDE A E .O.L. NO NO SIDE B

1040CDM

E AE SESWT H AM TY N ALUE VA AND E YP T ME SA THE WITH S E US F LACE REP

OT T MO L U CNRLER NTHS 1048 HIS IN T RS CONTROLLE SUB ALL OF RM TE 1048 TX TO THIS IN CONTROLLERS UB S LL F A RM O TE RX TO

12V Fuse 1.5A 250V 3AG 250V 1.5A Fuse 12V 12V Fuse 1.5A 250V 3AG 250V 1.5A Fuse 12V 3AG 250V 1.5A Fuse 12V 3AG 250V 1.5A Fuse 12V 3AG 250V 1.5A Fuse 12V 5V Fuse .5A 250V 3AG 250V .5A Fuse 5V

S ET J1 & J2 AS "SUB " IF S ET J1 & J2 AS "MA S" MA STE R

F4 F5 F6 F2 F3 THE RE IS NOT A MA S TER IF THE RE IS A MA S TER F1

CONTROLLER IN THIS 1048. CONTROLLER IN THIS 1048. fuse blown cates indi Doff LE

S UB MA S COMM UNICAT ION COMM UNICAT ION INT ERNAL TO 1048 J1 E XTE RNAL TO 1048 J2

485 IN 485 O UT

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27

GND GND GND GND GND GND

GND GND TX RX TX RX TX +TX- RX+ RX- RX+RX- TX + TX- +12V +5V +12V + + + + SUB MASTER A B C D A B C D 7A .5A 1.5A 12V 12V 12V 12V

INT ERNAL COMM 1048 T O 1048 CO MM-WIRE O UT TO IN, T X TO RX or A-A , B-B , C-C, D-D P OWER IN SECONDARY OUT POWER OUTPUT , 12V 1.5A TO EACH

12VDCA UX OUT UX 12VDCA VD U OUT AUX DC 5V

TO 1044 12VDC POWER INPUTS TO MA ST ER 1044 RX TE RM SEE "CONTROLLER TO CONTROLLER" TO MA ST ER 1044 TX TE RM COMM CHARTS FOR 485IN AND 485OUT 2 PAIR, 18 AWG WIRING SPECIF ICS 4 CONDUCTORS FROM 1040CDM TO 1040CDM P OWER OUT OF 1040 PDM RS-485 COMMUNICATIONS TO PDM TE RM 4, 12v+ 3.5A mp TO PDM TE RM 5, 12v- 3.5A mp 1048 W/ MASTER TO SUB TO PDM TE RM 6, 12v+ 3.5A mp TO PDM TE RM 7, 12v- 3.5A mp RS-485"IN" TO RS-485"IN" TX to RX RX to TX 1048 W/ SLAVE TO SUB RS-485"OUT" TO RS-485"IN" TX RX GND Master Port to PC RX to TX TX to RX 3 4 5 OR TO GND OF DSX-LAN (RS-232 PORT) DB9 SERIAL PORT PIN #5 (GND) POLARITY TO TX OF DSX-MCI (RS-232 PORT) DB9 SERIAL PORT PIN #3 (TX) DSX-MODEM (RS-232 PORT) TO RX OF DB9 SERIAL PORT PIN #2 (RX) ALWAYS + TO + AND - TO - DSX-USB (RS-232 PORT)

DSX Access Systems, Inc. 10731 Rockwall Road Dallas, Texas 75238 / 800-346-5288 / www.dsxinc.com 03/2020 DSX-1044 Power and Comm Connections

DSX-1044

1040E 34 35 36 37 38 39 40 41 42 43 Master 44 45 46 47 48 49 50 51 52 53 A :9 A :11 Comm on A :13 A :15 Comm on B :9 B :11 Comm on B :13 B :15 Comm on A :10 A :12 A :14 A :16 B :10 B :12 B :14 B :16

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 TX RX TX RX GND A :1 A :3 Comm on A :5 A :7 Comm on A :1 A:2B:1 B:2 B :1 B :3 Comm on B :5 B :7 Comm on +12V A :2 A :4 A :6 A :8 Open Open B :2 B :4 B :6 B :8 GND S UB PC-MA S TER DC IN Collectors Collectors DSX-1044 32 Input Board

RS-232 UP T O 50 FT DSX-LAN (RS -232 PORT) DB9 SERIAL PORT PIN #5 (GND) TX TO 1040CDM DSX -MCI (RS-232 PORT) RX OR DB9 SE RIAL PORT PIN #3 (TX ) DSX -MO DEM (RS-232 PORT) GND DB9 SERIAL PORT PIN #2 (RX) DSX -USB (RS-232 PORT) DSX-1044

34 35 36 37 38 39 40 41 42 43 SUB 44 45 46 47 48 49 50 51 52 53 A :9 A :11 Comm on A :13 A :15 Comm on B :9 B :11 Comm on B :13 B :15 Comm on A :10 A :12 A :14 A :16 B :10 B :12 B :14 B :16

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 TX RX TX RX GND A :1 A :3 Comm on A :5 A :7 Comm on A :1 A :2B :1 B :2 B :1 B :3 Comm on B :5 B :7 Comm on +12V A :2 A :4 A :6 A :8 Open Open B :2 B :4 B :6 B :8 GND S UB PC-MA S TER DC IN Collectors Collectors DSX-1044 32 Input Board WILL CAUSE ONE 60 SECOND B ATT ERY TE ST WHE N A CT IVE

FROM N.C. INPUT OF PDM / TO 1040PDM AC LOSS OUTPUT (PANEL PO WER) MO NITORS AC POWER LOSS OF SO URCE FO R LOCKS TO NEXT TO 1040PDM LOW BATTERY OUTPUT S UB IN THIS TX RX 1048 S UB

S ET J1 & J2 AS "S UB" S ET J1 & J2 AS IF THE RE IS NOT A "MA S" MA ST ER IF MASTER SUB MAS THERE IS A MASTER DSX-1040CDM CONTROLLER IN THIS J1 CONTROLLER IN THIS 1048. J2 1048.

485 IN 485 O UT

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27

GND GND GND GND GND GND

GND GND TX RX TX RX TX +TX- RX+ RX- RX+RX- TX + TX- +12V +5V +12V + + + + S UB MA S TER A B C D A B C D 7A .5A 1.5A 12V 12V 12V 12V

INT ERNAL COMM 1048 T O 1048 CO MM - WIRE O UT TO IN, T X TO RX or A-A , B-B, C-C, D-D POWER IN SECONDARY OUT POWER OUTPUT , 12V 1.5A TO EACH

VD U OUT AUX DC 5V OUT AUX 12VDC 2 PAIR, 18 AWG TO SUB RX TO SUB T X 4 CONDUCTORS FROM SEE "CONTROLLER TO P OWER OUT OF 1040 PDM FROM M ASTE R RX CONTROLLER" COMM TO 1044 12VDC FROM M ASTE R TX CHARTS F OR 485IN AND 485OUT WIRING SPECIFICS POWER INPUTS TO TE RM 4 OF PDM

TO TERM 5 OF PDM TO TE RM 6 OF PDM TO DSX-LAN TO TE RM 7 OF PDM

TO INPUT O F PANEL / N.C.CONTACTS S UPP LY N.C. DRY CONT ACTS FROM F IRE PANE L

SHO RT = NORMAL , OPEN = OVERRIDE 1k EOL 1k TO NEXT PDM OR T O INPUT 115V/60HZ or 240V/50HZ AC FOR ALA RM INDICA TIO N LOCK N.C. CONTACTS

POWER TO TO LOCK POWER SUPPLY IS ORDERED SEPARAT ELY SOURCE LOCK OUTP UT A ND IS NOT INCLUDED IN THE PKG PA RTS LIST RELA Y 15V OR 27V O UT LOCK 1 LOCK 2 LOCK 3 LOCK 4 A C

LOCK GND FIRE (Rev 10) DSX-1040PDM INP UT LOSS TO TO TO TO OV ERRIDE LOCK P ANE L LOCK P ANE L + - 115V/60HZ or 240V/50HZ AC 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 PANEL PANEL INPUT

POWER +15V 1 SOURCE 2 POWER IN O K GND LOCK POWER FIRE 1 3 15V OUT GND 3 ON OV ERRIDE NORMA L OF LOCKS 2 4 SEE "POWER SUPPLIES" J14 LOCK S 1&2 12V 12V 12V 12V S ECTION FO R PO WER 12V OUT FUSE J13 LOCK S 3&4 24V 24V 24V 24V SOURCE CONNECTION 8A 3AG 250V J9 IN J10 OUT J7 IN J8 OUT S PE CIFICS J11 LOCK S 7&8 LOCK S LOCK S 5&6 TO J12 J5 IN J6 OUT J3 IN J4 OUT 2 PAIR, 18 AWG CDM 12V 12V 12V 12V TO 1040CDM BYPASSED LOAD 24V 24V 24V 24V TO CDM TERM 13 +12V 4 P OWER 3.5A S HED OUT BATT . V. 5 7 TO CDM TERM 14 GND 5 ACTIVE LOAD J1 TO CDM TERM 13 +12V S HED 24V 3.5A 6 J2 6 8 TO CDM TERM 14 INA CTIVE GND 7 12V BACKUP F OR LOCKS BACKUP F OR PANELS

NOTE /// LOCK BATT ERY CONNECTIONS 18 19 20 21 22 23 24 25 26 27 28 29 (PINS 15-17) AND VO LTAG E SE LECT B ATT 15 16 17 TE ST B ATT + B ATT ERY - JUMPER (J1) M UST MATCH LOCK POWER IN 8 9 10 11 12 13 14 TO TO TO TO A C LOS S B ATT ERY + ON (PINS 30 & 31). P ANE L LOCK P ANE L LOCK LOW BATTERY B ATT ERY - B ATT S PLICE POINT FO R

TO INPUTS TEST 24V BATT ERY HOOKUP LOCK 5 LOCK 6 LOCK 7 LOCK 8

kEOL E 1k kEOL E 1k TO B/U TO B/U TO TO B ATT ERY (S) B ATT ERY (S) OUTPUT RELA Y LOCK

B ATT ERY TE ST INITIAT OR / TO MONITOR FOR LOW BATT ERY POWER FOR PANELS GROUND TO ACT IVAT E TEST 1040PE TO MONITOR AC POWER LOSS OF POWER F OR PANELS

DSX Access Systems, Inc. 10731 Rockwall Road Dallas, Texas 75238 / 800-346-5288 / www.dsxinc.com 03/2020