Columbia Pike Special Figure 3-2 Revitalization District Local Land Use in the Vicinity of ANC

LEGEND Land Use Columbia Pike Myer-Henderson Hall Arlington National Cemetery Residential

d Commercial lv Fort Myer Heights B n North Special District Government/Community Facility to g in h Hotel s a Radnor-Fort W Mixed Use - Residential S Myer Heights Sheraton Office Radnor Heights National East Special District Park / Open Space Hotel Area within ANC Under NPS Jurisdiction Arlington County Special Planning Areas Columbia FoxcroftPike Heights Netherlands Arlington Arlington House Carillon Ridge Park Southgate Rd Arlington Memorial Bridge and Avenue U.S. Marine ¨¦§395 Corps War Memorial U.S. Air Force Memorial

110 y Pentagon UV a w Arlington National Cemetery rk City a P Real Property Master Plan al ri o m Programmatic Me UV27 on ngt Environmental Assessment shi Wa ¯ e rg Feet o 03195 90780 e G Pentagon Source: 2012 General Land Use Plan (Arlington County), Arlington County GIS (NPS) Columbia Pike Special Figure 3-2 Revitalization District Local Land Use in the Vicinity of ANC

LEGEND Land Use Columbia Pike Joint Base Myer-Henderson Hall Arlington National Cemetery Residential

d Commercial lv Fort Myer Heights B n North Special District Government/Community Facility to g in h Hotel s a Radnor-Fort W Mixed Use - Residential S Myer Heights Sheraton Office Radnor Heights National East Special District Park / Open Space Hotel Area within ANC Under NPS Jurisdiction Arlington County Special Planning Areas Columbia FoxcroftPike Heights Netherlands Arlington Arlington House Carillon Ridge Park Southgate Rd Navy Annex Arlington Memorial Bridge and Avenue U.S. Marine ¨¦§395 Corps War Memorial U.S. Air Force Memorial

110 y Pentagon UV a w Arlington National Cemetery rk City a P Real Property Master Plan al ri o m Programmatic Me UV27 on ngt Environmental Assessment shi Wa ¯ e rg Feet o 03195 90780 e Potomac River G Pentagon Source: 2012 General Land Use Plan (Arlington County), Arlington County GIS National Park Service (NPS) Arlington National Cemetery Ord & Weitzel Gate Arlington, VA

Design by: Joe Weik Date: Drawing Code: Cover IRC 2009 Submitted By: 8/13/2013 IBC 2009 Gate Logic

NEC 2011 Contract Number: A Division of Losef Technologies Remarks: 1069 West Broad St #762 Falls Church, VA 22046 VA Scale Class A Traffic Control Gate All rights reserved. Contractor See Page Key Marshall Drive

Lamp Post

N Digital Keypad

15' 15' This page has been approved for construction by: Existing Iron Swing Gate Existing Iron Swing Gate Arlington National Cemetery Signature______

Holding Loop Title______Manhole Date______

Arlington National Cemetery Signature______

Existing Electrical Boxes

5' 5' Title______

4" x 4" Steel Support Post Infrared Beam Sensor Date______Pedestrian Gate 12' 26' Sensing Edge Concrete Trench Notes:

Sensing Edge All new buried conduits to be schedule 40 PVC. Slide Smart Operator Drive Chain

38'6" 5' All wiring insulation is to be rated for its use.

Minimum 1/2" x 8' grounding electrode at each location shown. Minimum 10 awg GEC.

Sidewalk

Holding Loop Installation to utilize gray electrical conduit with sweep Ls glued tight. All exposed wiring shall be sunlight resistant. Mulch Area

Digital Keypad

Bench Storm Drain

Design by: Joe Weik Submitted To: Gate Logic Security

Contract Number:

Scale 8' Lamp Post Storm Drain Date: Drawing Code: 8/10/2013 ANC O & W Gate Remarks: Page: Layout 1 Marshall Drive

Wireless Digital Keypad

Lamp Post

N

This page has been approved for construction by:

Arlington National Cemetery Signature______

Title______Existing Iron Swing Gate Existing Iron Swing Gate Date______

Arlington National Cemetery

Manhole Signature______

Title______Masonry Column Date______

RF Antenna Notes:

Masonry Wall Reflector Gate to be activated by digital code.

Infrared Beam Sensor Pedestrian Gate Gate to close by reset loop after vehicle clears gate area. Existing Electrical Boxes

4" x 4" Steel Support Post Photo Eye and bumper edge to prevent entrapment.

3/4" PVC c. Equipment to include gate edge transmitters Slide Smart Operator and receiver. RF receiver to allow for digital keypad Grounding Electrode and remote transmitters. Gate operator to include battery backup for power failure. Sidewalk Bushes and landscaping to be kept clear of gate by ANC staff.

3/4" PVC c. w/ 16/4 & ground

Digital Keypad

Mulch Area

Bench Storm Drain Design by: Joe Weik

Submitted To: Gate Logic Security

Contract Number:

Scale 8'

Date: Drawing Code: 8/13/2013 ANC O & W Gate Remarks: Lamp Post Storm Drain Page: Electrical 2 Marshall Drive

Top 3" above grade 14" x 14" x 30" pad

Lamp Post

N 15' 15' Existing Iron Swing Gate Existing Iron Swing Gate This page has been approved for construction by:

Arlington National Cemetery

Manhole Signature______Title______R=30' Masonry Column Date______

24" x 24" x 30" Footing Arlington National Cemetery Notch Curb to lower gate to 4" AG Notch Curb to lower gate to 4" AG Signature______

1'4" 1'4" Masonry Wall Pedestrian Gate Title______2'2" 2'2" Concrete Trench, slope to drain 1/16th" per foot minimum 38'6" Date______

Dimensions may vary due to field conditions. Notes: Concrete to be minimum 3000 psi air entrained. 24" x 24" x 30" Footing for outside use. 24" x 24" x 30" Footing Curb to retain soil

Top 3" above grade 24" x 24" x 30" pad Sidewalk 15' 15'

Dimensions in red are critical for pre ordered gate.

14" x 14" x 30" pad Top 3" above grade

Mulch Area

Bench Storm Drain

Design by:

R=15' Joe Weik R=18' Submitted To: Gate Logic Security

Contract Number:

Storm Drain Scale Lamp Post 8'

Date: Drawing Code: 8/13/2013 ANC O & W Gate Remarks: Page: Concrete 3 12' 26'6"

4' 4' 4' 5'3 5/8" 5'3 5/8" 5'3 5/8" 5'3 5/8" 5'3 1/2"

1" Picket

Gate 2 has been approved for construction by: 6" 6" Arlington National Cemetery Signature______5' 5' Title______

Date______

Gate 4 has been approved for construction by: Arlington National Cemetery Signature______

1" Picket 4 Title______

Date______

Notes:

5' 5' Gate support post to be 4" x 4" x 3/16".

All metal to be painted or powder coated black.

Gate support post to be at least 36" below grade. Gate pickets to be 1". Gate to be supported on HD truck rollers 2 Concrete to be minimum 3000 psi air entrained. for outside use.

Unverified Column Footer

Dimensions in red are critical for pre ordered gate.

Post Footer 2'2" 2'2" Concrete Trench, slope to drain Flange bolt bottom of post if 1'4" 1'4" 1'4" 1'4" column footer conflicts

2' 2' Operator Pad

39'7/16"

2' Design by:

Grade Bottom of Gate Joe Weik Open Gate Bottom of Gate Submitted To: 1'6" 1'6" Street Grade Gate Logic Security 4" 4" 3' 3' 2'6" 2'6" Contract Number: Curb & Gutter Operator Pad

Gate Post Scale 8' 12' Date: Drawing Code: 8/13/2013 ANC O & W Gate Remarks: Page: Gate View 4 Arlington National Cemetery Ord and Weitzel Gate Routes #$!"66 N. Fort Myer Dr.

66 N. Meade St. #$!"

N. Marshall Dr.

Ord & Weitzel Gate

·Æ50 Arlington National Cemetery

·Æ27 #$!"93 5

µ #$!"93 5 Area of Potential Effect µ

Direct Effect

Visual Effect

0 25 50 100 Feet µ

Alternative Pedestrian Route