Product Brief Emulex® Gen 6 Fibre Channel HBAs LPe31000/LPe32000-Series Faster Flash. Better Virtualization. Lossless Networking.

The Emulex Gen 6 (16/32G) APIs and tools, and the strength Fibre Channel (FC) Host to support high service- level Adapters (HBAs) by Broadcom agreement (SLA) applications. are designed to address the demanding performance, reliability Accelerate and management requirements of modern networked storage The unique Emulex Dynamic systems that utilize high Multi-core Architecture delivers performance and low latency solid unparalleled performance and state storage drives for caching more efficient port utilization than and persistent storage as well as other HBAs by applying all ASIC Faster Flash arrays. resources to any port that needs it. • Completes data warehousing Compared to the previous transactions in 1/4 of the time1 Fibre Channel is the gold standard generation, Emulex Gen 6 HBAs • Meet the massive bandwidth for network storage connectivity in requirements of flash storage arrays enterprise and cloud deployments. deliver 2x greater bandwidth — with up to 32GFC throughput and The latest Emulex Gen 6 FC HBAs 12,800 MBps (2 ports 32G, or 4 enable next-gen 128GFC SANs offer higher performance, lower ports 16GFC, full duplex), less than • Maximize the performance of latency, enhanced diagnostics and half the latency, and support an flash-based systems by prioritizing industry-leading 1.6 million IOPS mission-critical traffic in congested manageability that benefit both networks with the exclusive 16GFC and 32GFC environments on a single port, ensuring SLAs ExpressLane feature and next-gen 128GFC SANs. are met. The quad-port LPe32004 • NVMe-enabled capability delivers Emulex LPe31000-series HBAs supports SANs of up to 128GFC an additional 55% lower latency and are available with single, dual or by quadrupling throughput from supports NVMe over Fibre Channel 32GFC to 128GFC to deliver full- and traditional SCSI over Fibre quad 16GFC optics that can be Channel concurrently upgraded with 32GFC optics to duplex speeds of 25,600 MBps and up to 3.2M IOPS per . Better Virtualization utilize the full performance of Gen 6 FC technology. A second quad- 128GFC and 32GFC provide • Near limitless scalability to support port 16GFC model is available that seamless backward compatibility maximum VM density with 2X more to 16GFC and 8GFC networks. on-chip resources & bandwidth features a low-profile design. It • Improved VDI experience with low- provides the highest port density latency HBAs providing noticeable within a low-profile form factor. improvements during boot storms 1. Demartek TPC-H testing performed with The LPe32000-series HBAs are Emulex Gen 6 FC HBAs in a Microsoft • Simplified management & available with single, dual or quad SQL environment vs. the previous installation with OneCommand® 32GFC optics. generations of HBAs Manager plug-in for VMware vCenter server 2. Based on published FIELD MTBF of 10 million hours for the Emulex family of FC Unique to Fibre Channel HBAs. Lossless, Reliable technology is its deep ecosystem Networking support making it ideal for large EMULEX • Near zero downtime— FC’s lossless scale, easy-to-manage storage design ensures no dropped packets deployments. Users can count on and maximum uptime a complete suite of management • Industry Leader for Reliability— software, in-box drivers for Emulex HBAs can provide up to 1,141 years of uninterrupted service!2 mainstream server operating systems, software-defined storage

Emulex Gen 6 Fibre Channel HBAs Product Brief

Emulex Gen 6 HBAs are an complex user environments such Emulex HBA troubleshooting is excellent choice for database as blade system implementations. simplified with OneCapture, an applications as recent TPC-H FEC is a digital signal processing Emulex device driver utility that testing in a data warehousing technique that introduces gathers system, adapter, device environment have demonstrated redundant data, called an error driver, and applications information. up to 71% faster completion times correcting code, prior to data Data collected by OneCapture vs. the previous generations of transmission. FEC then provides the is compressed into a single file HBAs. To enable the highest Virtual receiver with the ability to correct and can be sent to Broadcom Machine density, Gen 6 HBAs errors without a reverse channel to Technical Support for analysis when provide support for up to 255 request the retransmission of data, debugging system issues or for virtual functions, 1,024 Message which improves performance. diagnostic purposes. Signaled Interrupts and expansive on-board context for exchanges T10 Protection Information The LPe31000/LPe32000-series and logins. (T10-PI) data integrity with high HBAs support Brocade I/O Insight performance hardware offload for Gen 6 FC, which proactively and NVM Express (NVMe) is a relatively provides data protection from the non-intrusively monitors device and new protocol for solid-state storage server to the storage array. As application-level IO to gain insights devices built with non-volatile one of the founders of the Data into performance and availability, memory technologies. NVMe Integrity Initiative (DII), Emulex, ensuring predictable performance provides substantially lower latency along with Oracle and Seagate, and operational stability. for storage I/O operations and was instrumental in defining the significantly higher IOPS per device. T10-PI standard, which, along Additionally Emulex HBAs support NVMe scales-up the number of with the Data Integrity Extensions the following Brocade features: devices it can address by adopting (DIX) standard, delivers full • ClearLink (D_Port)- automated NVMe over Fabrics technology. end-to-end data integrity. T10- end-to-end signal integrity PI assures the validity of I/O checks help identify any cabling, Emulex Gen 6 HBAs are NVMe over operations through the exchange of optics or port issues in minutes Fibre Channel-enabled, providing verification information during data versus hours. an additional 55% lower latency transmissions. for storage I/O operations versus • Link Cable Beaconing- locates a SCSI. Gen 6 NVMe-enabled HBAs Emulex HBAs are renowned for connection on either the Brocade support NVMe over Fibre Channel reliability, ensuring maximum switch port or the Emulex and SCSI over Fibre Channel SAN uptime. Their “It Just Works” HBA port by making the LED concurrently, allowing datacenters reputation is based on 17 million port blink for easy end-to-end to transition to all-flash storage at installed ports with proven identification. their own pace. industry-leading reliability of 10 • Host Name Registration- million hours field Mean Time eliminates the need to manually Between Failures (MTBF). Protect associate worldwide port names Emulex Gen 6 FC HBAs deliver with servers, with automated enhanced security via the new Control capture of information from secure firmware update feature The flagship OneCommand Emulex HBA ports. Manager enterprise-class which protects and ensures the • Read Diagnostic Parameters- management application features authenticity of device firmware. Brocade switches and Emulex a multiprotocol, cross-platform HBA ports will self-report architecture that provides Forward Error Correction (FEC) diagnostic information, including centralized management of all is a Gen 6 Fibre Channel standard port speed, link errors, and SFP current and previous generations feature that provides enhanced information (temperature, Tx and of Emulex FC HBAs. This enables IT data reliability and performance Rx power, etc.). by automatically detecting and administrators to manage network recovering from errors. It is connectivity with one tool for especially useful in diverse and maximum efficiency.

Emulex Gen 6 Fibre Channel HBAs Product Brief

Standards Comprehensive OS and Environmental General Specifications Hypervisor Support Requirements

• The LPe31000/32000-series • Microsoft Windows • Operating temperature: 0° to FC HBAs are powered by the 55°C (32° to 131°F); 150 LFM • Red Hat Enterprise Linux XE501 controller and utilizes required an eight-lane (x8) PCIe 3.0 bus • SUSE Linux Enterprise Server −− 200 LFM required for (backward compatibility to PCIe LPe31004-M6 model 2.0 supported)—the architecture • Oracle Solaris −− 250 LFM required for full-height enables all resources to be “-SEO” models • VMware vSphere applied to any port that needs • Storage temperature: -20° to • Additional support is available it, delivering over 1.6M IOPS on a 85°C (-4° to 185°F) single-port from OEMs and partners • Relative humidity: 5% to 95% • The quad-port LPe32004 utilizes non-condensing a 16 lane (x16) PCIe 3.0 bus and Hardware Environments delivers 3.2M IOPS per adapter. • PowerPC, SPARC, x86, x64 Agency and Safety Industry Standards Approvals Optical • Current ANSI/IETF Standards: North America FC-PI-4; FC-PI-5; FC-PI-6; FC- • Data rates: 28.05 Gb/s (32GFC); • FCC/ICES Class A FS-3; FC-LS-2; FC-GS-6; FC-DA; 14.025 Gb/s (16GFC); 8.5 Gb/s • UL/CSA Recognized FC-DA-2; FCP-4; SPC-4; SBC-3; (8GFC); 4.25 Gb/s (4GFC) SSC-4 automatically negotiated Europe • Legacy ANSI/IETF standards: • Optics: Short wave lasers with LC • CE Mark FC-PH; FC-PH-2; FC-PH-3; FC-PI; type connector FC-PI-2; FC-PI-3; FC-FS; FC- • EU RoHS compliant GS-2/3/4/5; FCP-2/3; FC-HBA; • Cable: Operating at 32 Gb FC-TAPE; FC-MI; SPC-3; SBC-2; −− 20m at 32 Gb on 50/125 μm OM2 • TUV Bauart Certified MMF SSC-2; SSC-3 −− 70m at 32 Gb on 50/125 μm OM3 Australia • PCIe base spec 3.0 MMF −− 100m at 32 Gb on 50/125 μm OM4 • RCM • PCIe card electromechanical spec MMF 3.0 Japan • Fibre Channel Class 3 Physical Dimensions • VCCI Class A • PHP hot plug-hot swap • Short, low profile PCIe card Taiwan • 167.64 mm x 68.91 mm Architecture (6.60” x 2.71”) • BSMI Class A Single-port LPe32000, dual-port • Standard bracket LPe32002 or quad-port LPe32000 Korea (low profile bracket ships in box) • Supports 32GFC, 16GFC and • MSIP (formerly KCC/MIC) Class A • LPe31004-M6-SIO & 8GFC link speeds, automatically LPe32004-M2-SIO are full-height negotiated China PCIe cards: 167.64 mm x 111.15 mm (6.60” x 4.38”), with a standard • China RoHS Compliant Single-port LPe31000, dual-port bracket LPe31002 or quad-port LPe31004 • Supports 16GFC, 8GFC and 4GFC link speeds, automatically negotiated

Emulex Gen 6 Fibre Channel HBAs Product Brief

Ordering Information Added Features Management Features LPe31000-M6⁴ Performance Features • The Emulex OneCommand (upgradeable to 32GFC) Manager application enables • 1 Port 16GFC Short Wave Optical – • Doubling the maximum FC link centralized discovery, monitoring, LC SFP+ rate from 16GFC to 32GFC and enhanced virtualization capabilities, reporting, and administration of HBAs provided by Emulex on LPe31002-M6⁴ help support IT “green” initiatives. (upgradeable to 32GFC) local and remote hosts. Powerful • Frame-level multiplexing increases automation capabilities facilitate • 2 Ports 16GFC Short Wave Optical link efficiency and maximizes HBA remote driver parameter, firmware – LC SFP+ performance. and boot code upgrades. LPe31004-M6³ • Accelerates network access • Advanced diagnostic features, • 4 Port 16GFC Short Wave Optical – to SSDs with NVMe over Fibre such as adapter port beaconing LC SFF (embedded optics) Channel enabled feature — and adapter statistics, help supports the FC-NVMe INCITS T11 optimize management and LPe31004-M6-SIO⁴ standard. network performance, while the (upgradeable to 32GFC) environmental monitoring feature • 4 Port, full-height 16GFC Short Data Protection Features helps to maintain optimum host- Wave Optical- LC SFP+ • End-to-end data protection with to-fabric connections. In addition hardware parity, CRC, ECC and to the GUI interface, management LPe32000-M2 other advanced error checking and functions can also be performed • 1 Port 32GFC Short Wave Optical – correction algorithms ensure data is via a scriptable Command Line LC SFP+ safe from corruption. Interface (CLI) as well as a web browser. LPe32002-M2 • Enhanced data protection provided • 2 Port 32GFC Short Wave Optical – by T10-PI with high-performance • Troubleshoot optics and cables LC SFP+ offload. T10-PI provides additional before critical errors affect your data protection in Oracle system with Brocade ClearLink LPe32004-M2-SIO Unbreakable Linux environments. supported Switches and Emulex • 4 Port, full-height 32GFC Short HBAs. Wave Optical- LC SFP+ Deployment and Management • Meet SLAs and QoS with Features ExpressLane application Options prioritization on hosts. ExpressLane • When upgrading LPe31000-series • Universal boot capability allows the is fully compatible with majority of 16GFC models to 32GFC, Broadcom appropriate boot environment to switches offering QoS features. 32GFC optical transceiver kits must be automatically selected for any be used. To order use the following given hardware. • OneCommand Manager supports part numbers: • Boot from SAN capability reduces role-based management to system management costs and facilitate administration of adapters LP32-SW-OPT-1 increases uptime. throughout the • 32GFC Short Wave Optical without compromising security. (1 piece kit) • Detailed, real-time event logging Management privileges can be and tracing enables quick diagnosis assigned based on LDAP and AD of SAN problems. group memberships. LP32-SW-OPT-2 • 32GFC Short Wave Optical • Beaconing feature flashes the HBA • Emulex’s management (2 piece kit) LEDs, simplifying their identification instrumentation complies to open within server racks. management standards, such as SMI-S and common HBA API • Environmental monitoring feature support, which enables seamless helps optimize SAN availability. upward integration into enterprise 3. LPe31004-M6 model uses embedded optics storage and server management and cannot be upgraded to 32GFC solutions. 4. Only Broadcom certified optical transceiver kits can be used

Visit the Broadcom website at: www.broadcom.com

Broadcom, the pulse logo, Connecting everything, Emulex, and OneCommand are among the trademarks of Broadcom. Copyright © 2018 Broadcom. All Rights Reserved. The term “Broadcom” refers to Broadcom Limited and/or its subsidiaries. For more information, please visit www.broadcom.com. BC00-0365EN 03.05.18 Mouser Electronics

Authorized Distributor

Click to View Pricing, Inventory, Delivery & Lifecycle Information:

Broadcom Limited: LPE31002-M6 LPE31000-AP LPE32002-M2 LPE32002-AP LPE32000-AP LPE31000-M6 LPE31004-M6 LP32- SW-OPT-1 LPE32000-M2 LP32-SW-OPT-2 LPE31002-AP LPE31004-AP LPe35002-M2 LPe35000-M2