(33038) Insulin Continuous Self Administered SQ Pump

Total Page:16

File Type:pdf, Size:1020Kb

Load more

(33038) Insulin Continuous Self Administered SQ Pump Please note bolded orders are preselected in Excellian®. Continuous Self-Administered Subcutaneous Insulin Pump Diagnosis Allergies Metered Glucose (Single Select Section) Metered Glucose - Scheduled QID, AC and HS and 2 AM. 1. And PRN if patient symptomatic or as requested by patient. 2. Bedside blood glucose meters are not reliable when glucose greater than 500. Obtain serum glucose until glucose less than 500. 3. Use facility glucose meter Metered Glucose – NPO 1. Leave insulin pump in place and infusing hourly basal rate and check metered glucose every *** hours. 2. Bedside blood glucose meters are not reliable when glucose greater than 500. Obtain serum glucose until glucose less than 500. 3. Use facility glucose meter. Nursing Blood Glucose Greater Than Or Equal To 1. Have patient administer insulin via pump (amount to be 250 mg/dL determined by patient). 2. Recheck blood glucose in 1 hour. 3. If blood glucose is greater than or equal to 250, provide subcutaneous insulin coverage as specified in orders, and troubleshoot potential pump problems. 4. If problem unresolved and unless otherwise specified, contact physician for subcutaneous insulin orders. Insulin Pump Agreement - Patient to Sign Scan into medical record. Continuous Self-Administered Subcutaneous Insulin Pump Agreement Insulin Pump Worksheet - Patient to Complete and Every shift. Verify and document the patient reported insulin Nurse to Review and Document pump setting and dosing on eMAR. Scan worksheet into medical record. Provider Initials Page 1 of 3 Patient Name _________________________________________ Medical Record # _________________ Date of Birth _________ Date of Surgery/Admission ______________________________ PROVIDER’S ORDERS 02/07/2012 (33038) Insulin Continuous Self Administered SQ Pump Please note bolded orders are preselected in Excellian®. Insulin Pump Use / Site - Assessment 1. Nurse to assess, every shift and with changes in clinical condition, the patient's ability to meet criteria for operating pump independently throughout hospitalization. 2. If patient status changes, call physician to change insulin administration to subcutaneous or intravenous insulin. 3. Assess infusion site every shift for inflammation or irritation. Insulin Pump Maintenance - Patient to Perform All Including refilling of pump, tubing changes, site care, and Maintenance rotation. Medications – Hypoglycemia hypoglycemia protocol See Facility Specific Protocol. Medications – Insulin BASAL and BOLUS (Single Select Section) Provider: Please document settings in progress note. insulin aspart (NOVOLOG) – BASAL and BOLUS CONTINUOUS, Subcutaneous. Turn off insulin pump immediately if blood glucose is less than [ ] and follow hypoglycemia protocol. insulin lispro (HUMALOG) – BASAL and BOLUS CONTINUOUS, Subcutaneous. Turn off insulin pump immediately if blood glucose is less than [ ] and follow hypoglycemia protocol. insulin regular U-500 CONCENTRATED CONTINUOUS, Subcutaneous. (HUMULIN) - BASAL and BOLUS Note: Medication is 5 times the concentration of other insulins Turn off insulin pump immediately if blood glucose is less than [ ] and follow hypoglycemia protocol. Medications – Insulin: Coverage for Off Pump > 1 hour or Suspected Pump Malfunction (Consider adding basal insulin if off pump greater than 4 hours) (Single Select Section) insulin aspart (NOVOLOG) EACH TIME PRN, Subcutaneous, Dose: [ ] units. PRN x1 for each occurrence for suspected pump malfunction or at time of pump removal if patient is to be off pump for over 1 hour. insulin lispro (HUMALOG) EACH TIME PRN, Subcutaneous, Dose: [ ] units. PRN x1 for each occurrence for suspected pump malfunction or at time of pump removal if patient is to be off pump for over 1 hour. Laboratory Serum Glucose PRN, STAT. If bedside metered glucometer results are greater than 500 ml/dl obtain serum glucose every hour until glucose less than 500 ml/dl. Nurse to release order. Hemoglobin A1c ONE TIME. Today. Provider Initials Page 2 of 3 Patient Name _________________________________________ Medical Record # _________________ Date of Birth _________ Date of Surgery/Admission ______________________________ PROVIDER’S ORDERS 02/07/2012 (33038) Insulin Continuous Self Administered SQ Pump Please note bolded orders are preselected in Excellian®. Consults – It is suggested to Consult an Endocrinologist if available at your site. Consult to Physician (Specify) Reason for consult: [ ]. Indicate the physician or group [ ]. Staff to call consulting office, add provider to the treatment team, and update order with date and time of call. Consult to Diabetes Nurse Educator ONE TIME. Today. Additional Orders ________________________________ ________ __________ Provider Signature Date Time Provider Initials Page 3 of 3 Patient Name _________________________________________ Medical Record # _________________ Date of Birth _________ Date of Surgery/Admission ______________________________ PROVIDER’S ORDERS 02/07/2012 .
Recommended publications
  • Thinking of Starting Insulin

    Thinking of Starting Insulin

    Thinking of starting insulin Many medications are used to What happens in diabetes? manage diabetes, but the one that Type 1 diabetes most people have heard about is The pancreas is no longer able to make insulin. As a result, people diagnosed insulin. If you are thinking of starting with type 1 diabetes will need to start on insulin immediately and take it for insulin, here are some things you life. Insulin is given either with multiple daily injections using insulin pens or will want to know. syringes or by using an insulin pump. What is insulin? Type 2 diabetes Insulin is a hormone produced The pancreas no longer produces enough insulin or the body is not able to by the pancreas to control the use its own insulin effectively. If you have type 2 diabetes, you may be able amount of glucose (sugar) in the to keep your blood sugar levels in your target range through healthy eating, blood. Without insulin, sugar builds physical activity, and by taking diabetes medication. Ask your doctor to refer up in the bloodstream. This can you to a diabetes educator (nurse, dietitian, or pharmacist) who can help you lead to serious health problems, with lifestyle changes and managing your blood sugar levels. Type 2 diabetes such as blindness, heart disease, is a progressive condition and, over time, many people will need to use kidney problems, amputation, nerve insulin to manage their blood sugar. damage, and erectile dysfunction. How do I feel about starting insulin? Looking forward to good Sometimes people feel scared, nervous, or guilty about having to start insulin health therapy, and that’s okay.
  • Adult Glucose Monitoring Equipment, Insulin Pumps, and Supplies: FAQ's

    Adult Glucose Monitoring Equipment, Insulin Pumps, and Supplies: FAQ's

    HEALTH EDUCATION HEALTH EDUCATION Adult Glucose Monitoring Equipment, Insulin Pumps, and Supplies: FAQ's Are glucose meters covered under my Health Plan benefit? Yes, home blood glucose meters and supplies are covered by your Health Plan benefit when your doctor prescribes them. The supplies Our goal is to find the include test strips, lancets, and lancing devices. The meter and best way to help you supplies are covered under a special benefit for members, called the manage your diabetes. Durable Medical Equipment (DME) benefit. These diabetes supplies You will work with your and all refills are available at any local Kaiser Permanente pharmacy. diabetes care team to Your health care provider may prescribe a home glucose meter and discuss your diabetes and supplies for you when: the equipment and • You have a diagnosis of diabetes; and supplies that may be • Blood sugar monitoring is medically necessary for you to control appropriate for you. your diabetes. What types of glucose meters are available at Kaiser Permanente? The LifeScan OneTouch® VerioTM IQ is the glucose meter that Kaiser Permanente health care providers prescribe most often. Some patients will have the OneTouch® Ultra® 2 meter instead, which is also an approved meter. Physicians may prescribe different meters for Kaiser Permanente members who are blind, have severe vision problems, or who have challenges using their hands and can’t use the OneTouch® VerioTM IQ meter. How many glucose meters are covered under my DME benefit? The DME benefit covers one working glucose meter at a time. You must have a valid prescription for a meter from your health care provider.
  • Research Article Impact of the Type of Continuous Insulin Administration on Metabolism in a Diabetic Rat Model

    Research Article Impact of the Type of Continuous Insulin Administration on Metabolism in a Diabetic Rat Model

    Hindawi Publishing Corporation Journal of Diabetes Research Volume 2016, Article ID 8310516, 10 pages http://dx.doi.org/10.1155/2016/8310516 Research Article Impact of the Type of Continuous Insulin Administration on Metabolism in a Diabetic Rat Model A. Schaschkow,1 C. Mura,1 S. Dal,1 A. Langlois,1 E. Seyfritz,1 C. Sookhareea,1 W. Bietiger,1 C. Peronet,1 N. Jeandidier,1,2 M. Pinget,1,2 S. Sigrist,1 and E. Maillard1 1 UMR DIATHEC, EA 7294, Centre Europeen´ d’Etude du Diabete,` UniversitedeStrasbourg(UdS),BoulevardRen´ eLeriche,´ 67200 Strasbourg, France 2Department of Endocrinology, Diabetes, and Metabolic Diseases, Poleˆ NUDE, Hopitauxˆ Universitaires de Strasbourg (HUS), 67000 Strasbourg Cedex, France Correspondence should be addressed to E. Maillard; [email protected] Received 8 April 2016; Revised 26 May 2016; Accepted 14 June 2016 Academic Editor: Bernard Portha Copyright © 2016 A. Schaschkow et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. Exogenous insulin is the only treatment available for type 1 diabetic patients and is mostly administered by subcutaneous (SC) injection in a basal and bolus scheme using insulin pens (injection) or pumps (preimplanted SC catheter). Some divergence exists between these two modes of administration, since pumps provide better glycaemic control compared to injections in humans. The aim of this study was to compare the impacts of two modes of insulin administration (single injections of long-acting insulin or pump delivery of rapid-acting insulin) at the same dosage (4 IU/200 g/day) on rat metabolism and tissues.
  • Insulin Pump Therapy

    Insulin Pump Therapy

    DIABETES TREATMENT ALGORITHMS SUPPLEMENT Insulin Pump Therapy Introduction The goal of insulin delivery is to regulate blood glucose levels to achieve normoglycemia. In someone without diabetes, pancreatic B-cells continuously secrete insulin throughout the day and night, providing a continuous insulin infusion or basal amount. In response to meals, the pancreas provides “bursts” of insulin referred to as boluses. Pump therapy is intended to more closely mimic this pancreatic function. Continuous subcutaneous insulin infusion (CSII) utilizes only fast acting insulins (Humalog, Novolog) and eliminates the use of long-acting insulins (NPH, Ultralente, Lantus). Pumps can deliver insulin in 0.1 unit increments as a basal/continuous flow between meals and through the night. Basal rates can be increased or decreased at any point, allowing for exercise, illness, skipped meals, sensitivity to insulin and the dawn phenomenon. Boluses of insulin can be delivered via the pump to provide insulin to compensate for carbohydrate intake and hyperglycemic episodes when needed. Insulin pump therapy gives people with diabetes the freedom to enjoy life, despite their chronic condition. The value of an improved lifestyle, increased flexibility and optimal diabetes control is obvious from the impact the insulin pump has made in the twenty-five years since its inception. The ability to control how and when insulin is delivered provides the “pumper” with increased flexibility in scheduling their day-to-day activities. For those people with erratic lifestyles, a desire to achieve optimal glycemic control (A1c ≤ 6.5%) and prevent chronic complications, the pump is an ideal choice. INDICATIONS FOR PUMP THERAPY Clinical Indications 1.
  • Subcutaneous Insulin Pump Management: Inpatient POLICY STATEMENT: PURPOSE: SCOPE: DEFINITIONS

    Subcutaneous Insulin Pump Management: Inpatient POLICY STATEMENT: PURPOSE: SCOPE: DEFINITIONS

    Current Status: Retired PolicyStat ID: 3428552 Effective: 03/2017 Approved: 03/2017 Last Revised: 03/2017 Expiration: 03/2020 Owner: Dustin Falk: Clinical Coordinator- Pharmacy Department: Pharmacy CSM References: Applicability: Columbia St. Mary's Hospital Milwaukee Columbia St. Mary's Hospital Ozaukee Sacred Heart Rehabilitation Institute Subcutaneous Insulin Pump Management: Inpatient POLICY STATEMENT: Inpatient insulin pump management requires careful coordination between the patient and medical staff. To provide safe and optimal care, a set of criteria must be met on admission and throughout the inpatient stay if the insulin pump is to be continued. All ADULT patients admitted with an insulin pump will be assessed using criteria outlined below. PURPOSE: To outlineRETIRED the roles and responsibilities related to caring for inpatients on an insulin pump. This policy refers to any ADULT patient admitted to the hospital who is using an external pump to manage his/her diabetes. Pediatric patients do not fall under the purview of this policy. SCOPE: This policy applies to all staff involved in the care of diabetic patients within the Columbia St. Mary's organization. DEFINITIONS: EHR: Electronic Health Record Insulin Pump: Battery operated device the size of a pager, which provides continuous 24 hour insulin delivery utilizing rapid acting insulin. Insulin is delivered through a needle or soft cannula that is inserted into the patient's subcutaneous tissue and connected to thin plastic tubing attached to the pump or has no tubing in the case of Omnipod™ pump. The pump mimics normal pancreatic function and is programmed by the patient to deliver insulin via basal rates and at each meal as a bolus dose.
  • The Leeds Insulin Pump Workbook for Children and Young People

    The Leeds Insulin Pump Workbook for Children and Young People

    The Leeds Insulin Pump Workbook for Children and Young People IABETES A service for children and LEEDS young people with diabetes YORKSHIRE This project has received funding from Medtronic Contents Welcome to the insulin pump workbook Introduction Starting pump therapy 1.1 Why is insulin necessary? 2.1 Getting started 1.2 Insulin pump therapy 2.2 Calculate and set basal rate 1.3 Benefits of insulin pump therapy 2.3 Calculate insulin to carbohydrate ratio 1.4 What types of insulin are used in a pump? 2.4 Calculate the correction dose 1.5 The basics of insulin pumps 2.5 Pump failure 1.6 Blood glucose monitoring and HbA1c 2.6 Removing the pump 1.7 End of section worksheet 2.7 Temporary basal rates 2.8 Emergency kit 1 2.9 End of section worksheet 2 Managing pump therapy Diet 3.1 Hypoglycaemia 4.1 Carbohydrate counting 3.2 Hyperglycaemia 4.2 Glycaemic index 3.3 Ketones 4.3 Advanced bolus options 3.4 Illness and diabetic ketoacidosis 4.4 End of section worksheet 3.5 Checking basal rate 3.6 Checking insulin to carbohydrate ratio 3.7 Continuous glucose monitoring and meter/pump downloads 3.8 A structured approach to interpretation of blood glucose readings 3.9 End of section worksheet 3 4 Life Appendices 5.1 Exercise and activity Appendix A: Record of insulin pump settings 5.2 Travel Appendix B: Adjusting basal rate charts 5.3 School/College and social life Appendix C: Useful websites/books and support groups 5.4 Illness Appendix D: Needle information 5.5 Menstruation Appendix E: End of section worksheet answers 5.6 Alcohol Appendix F: Glossary 5.7 Admission to hospital 5.8 Continuation of funding 5.9 Insurance 5.10 Identification of a medical issue 5.11 End of section worksheet 5 Welcome Welcome to your insulin pump workbook.
  • When Intensive Insulin Therapy (MDI)

    When Intensive Insulin Therapy (MDI)

    S180 Diabetes Care Volume 39, Supplement 2, August 2016 1 2 INSULIN THERAPY Ohad Cohen, Sebastiano Filetti, When Intensive Insulin Therapy Javier Castaneda,~ 3 Marianna Maranghi,2 (MDI) Fails in Patients With and Mariela Glandt4 Type 2 Diabetes: Switching to GLP-1 Receptor Agonist Versus Insulin Pump Diabetes Care 2016;39(Suppl. 2):S180–S186 | DOI: 10.2337/dcS15-3029 Treatment with insulin, alone or with oral or injectable hypoglycemic agents, is becoming increasingly common in patients with type 2 diabetes. However, approximately 40% of patients fail to reach their glycemic targets with the initially prescribed regimen and require intensification of insulin therapy, which increases the risks of weight gain and hypoglycemia. Many of these patients eventually reach a state in which further increases in the insulin dosage fail to improve glycemic control while increasing the risks of weight gain and hypoglycemia. The recently completed OpT2mise clinical trial showed that continuous subcutaneous insulin infusion (CSII) is more effective in reducing glycated hemoglobin (HbA1c) than intensification of multiple daily injection (MDI) insulin therapy in patients with type 2 diabetes who do not respond to intensive insulin therapy. CSII therapy may also be useful in patients who do not reach glycemic targets despite multi- drug therapy with basal-bolus insulin and other agents, including glucagon-like peptide (GLP)-1 receptor agonists; current guidelines offer no recommendations for the treatment of such patients. Importantly, insulin and GLP-1 receptor ago- nists have complementary effects on glycemia and, hence, can be used either sequentially or in combination in the initial management of diabetes. Patients 1 who have not previously failed GLP-1 receptor agonist therapy may show reduc- Sheba Medical Center, Tel Hashomer, Israel 2Dipartimento di Medicina Interna e Specialita` tion in weight and insulin dose, in addition to moderate improvement in HbA1c, Mediche, Sapienza University, Rome, Italy when GLP-1 receptor agonist therapy is added to MDI regimens.
  • Insulin Replacement Therapy

    Insulin Replacement Therapy

    Diabetes Educational Services Training Healthcare Professionals On State of the Art Diabetes Care Insulin Replacement Therapy Another Downloadable Article from the Diabetes Educational Services Site Insulin Replacement Therapy is an excellent review of strategies to effectively dose and adjust insulin for patients with type 1 and type 2 diabetes. It is authored by our faculty member, Evelyne Fleury Milfort. Diabetes Educational Services Beverly Dyck Thomassian 45 Old Chico Way Chico, CA 95928 530 893-8635 [email protected] http://www.diabetesed.net/ Insulin Replacement Therapy Vol. 16 •Issue 11 • Page 32 2009 Diabetes CE Insulin Replacement Therapy Minimizing Complications and Side Effects by Evelyne Fleury-Milfort, NP Objectives: The purpose of this article is to educate nurse practitioners about insulin replacement therapy. After reading this article, the nurse practitioner should be able to: * define insulin replacement therapy and discuss appropriate candidates for this form of insulin management * describe the major components of insulin replacement therapy * identify criteria for choosing insulin regimen modalities * explain the initiation and titration process for multiple daily injections and insulin pump therapy. Insulin therapy is the cornerstone of treatment for all patients with type 1 diabetes and for patients with type 2 diabetes who reach severe beta cell failure. Multiple studies have documented the importance of optimal glucose control to prevent the devastating complications of the disease. The best strategy to achieve optimal glucose control is to imitate normal insulin delivery. This continuing education article discusses strategies for the initiation and titration of insulin replacement therapy. Current State of Diabetes Diabetes has reached an epidemic level in the United States.
  • Providers | External Insulin Pump Policy

    Providers | External Insulin Pump Policy

    PROVIDER POLICIES & PROCEDURES _________________________ CONTINUOUS SUBCUTANEOUS INSULIN INFUSION PUMPS (CSII) The primary purpose of this document is to assist providers enrolled in the Connecticut Medical Assistance Program with the information needed to support a medical necessity determination for external insulin pumps. By clarifying the information needed for prior authorization of services, HUSKY Health hopes to facilitate timely review of requests so that individuals obtain the medically necessary care they need as quickly as possible. A continuous subcutaneous insulin infusion pump is a programmable, computerized device that is used to deliver a continuous subcutaneous insulin infusion into the body. Typically, these devices contain a 2-3 day supply of insulin connected to an infusion set or pod programmed to deliver basal amounts of insulin and bolus doses. The purpose of the device is to provide an accurate, continuous, controlled delivery of insulin to achieve improved glycemic control and to minimize and/or prevent acute and chronic complications. An external insulin pump is considered durable medical equipment (DME). CLINICAL GUIDELINE Coverage guidelines for insulin pumps for the treatment of diabetes are made in accordance with the Department of Social Services (DSS) definition of Medical Necessity. The following criteria are guidelines only. Coverage determinations are based on an assessment of the individual and his or her unique clinical needs. If the guidelines conflict with the definition of Medical Necessity, the definition of Medical Necessity shall prevail. The guidelines are as follows: Initial Insulin Pump Therapy Initial Pump Therapy without Continuous Glucose Monitoring (CGM) Integration The administration of insulin by an external continuous subcutaneous insulin infusion pump in an individual with diabetes requiring insulin therapy may be considered medically necessary when: A.
  • Exploring the Challenges Insulin Pump Technologies

    Exploring the Challenges Insulin Pump Technologies

    Exploring the Challenges & designing potential solutions for Insulin Pump Technologies Andy Harper - MID Candidate August, 2020 Wendell Wilson - Project Advisor Leila Aflatoony - Committee Member Wei Wang - Committee member 1 Acknowledgements First and foremost, I would like to acknowledge the diabetes community, the practitioners of Atlanta Diabetes Associates, and The Juvenile Diabetes Research Foundation for investing their time, recourses, and enthusiasm in helping me with this research. I approached you with very little to offer, and a lot to learn. You taught me enough to have a new outlook on living with T1 diabetes. It was an honor to share stories with other people living with T1D, and to learn about all the work that so many of you do to help people like myself. This was a totally affirming, enlightening, and humbling experience. Thank you to my advisor Wendell Wilson and committee members, Wei Wang and Leila Aflatoony. You were persistent and honest guides throughout the entire project. You pushed me to do some of my best work. Thank you for sharing your knowledge and experience in physical product design, research and analysis, experience design, and strategy. You gave me a renewed sense of self-confidence in my abilities and I have gotten to know myself better, as a designer. I am incredibly fortunate to have worked so closely with all of you! I can’t thank you enough for investing in me. 2 3 5-stage Project Abstract This study examines the current technology of diabetes Methodology management devices, primarily insulin pumps. Insulin pumps are effective tools for the precise control of glucose levels, for type 1 Phase 1: Background Research diabetes (T1D) patients.
  • Continuous Glucose Monitoring and Insulin Delivery for Managing Diabetes

    Continuous Glucose Monitoring and Insulin Delivery for Managing Diabetes

    UnitedHealthcare® Commercial Medical Policy Continuous Glucose Monitoring and Insulin Delivery for Managing Diabetes Policy Number: 2021T0347GG Effective Date: July 1, 2021 Instructions for Use Table of Contents Page Related Commercial Policy Coverage Rationale ....................................................................... 1 • Durable Medical Equipment, Orthotics, Medical Documentation Requirements ...................................................... 2 Supplies and Repairs/Replacements Applicable Codes .......................................................................... 2 Description of Services ................................................................. 6 Community Plan Policy Benefit Considerations .................................................................. 7 • Continuous Glucose Monitoring and Insulin Delivery for Managing Diabetes Clinical Evidence ........................................................................... 7 U.S. Food and Drug Administration ........................................... 13 Medicare Advantage Coverage Summary References ................................................................................... 14 • Diabetes Management, Equipment and Supplies Policy History/Revision Information ........................................... 16 Instructions for Use ..................................................................... 16 Coverage Rationale See Benefit Considerations Insulin Delivery External insulin pumps that deliver insulin by continuous subcutaneous infusion are
  • Insulin Pumps and Supplies Clinical Coverage Criteria Overview an External Insulin Pump Is a Device That Delivers Insulin Subcutaneously

    Insulin Pumps and Supplies Clinical Coverage Criteria Overview an External Insulin Pump Is a Device That Delivers Insulin Subcutaneously

    Insulin Pumps and Supplies Clinical Coverage Criteria Overview An external insulin pump is a device that delivers insulin subcutaneously. The insulin is delivered in a programmed and controlled manner and eliminates the need for the patient to self-inject insulin. The main goal in using an insulin pump is to achieve near normal blood glucose levels in order to prevent both acute and chronic complications of diabetes. Policy This Policy applies to the following Fallon Health products: ☒ Commercial ☒ Medicare Advantage ☒ MassHealth ACO ☒ NaviCare ☒ PACE Fallon Health follows guidance from the Centers for Medicare and Medicaid Services (CMS) for organization (coverage) determinations for Medicare Advantage plan members. National Coverage Determinations (NCDs), Local Coverage Determinations (LCDs), Local Coverage Articles (LCAs) and guidance in the Medicare manuals are the basis for coverage determinations. When there is no NCD, LCD, LCA or manual guidance, Fallon Health Clinical Coverage Criteria are used for coverage determinations. Medicare Benefit Policy Manual, Chapter 20, Section 110 describes the durable medical equipment benefit and coverage of supplies and accessories that are necessary for the effective use of durable medical equipment for Medicare beneficiaries. Medicare does not have an NCD for insulin pumps. Noridian Healthcare Solutions, LLC is the Durable Medical Equipment Medicare Administrative Contractor (DME MAC) with jurisdiction in our service area. Noridian Healthcare Solutions, LLC has an LCD for (MCD search 06-25-2021). For plan members enrolled in NaviCare and PACE plans, Fallon Health follows Medicare guidance for coverage determinations. In the event that there is no Medicare guidance or if the plan member does not meet medical necessity criteria in Medicare guidance, Fallon Health will follow guidance published by MassHealth.