BAR CODE Contents
Chapter 1 Description
1.1 Notice ...... 3 1.2 Introduction ...... 4 1.3 Codes Read ...... 4 1.4 Installation ...... 4 1.5 Pin Assignment ...... 6
Chapter 2 Configuration - General
2.1 Flow Chart ...... 8 2.2 Loop of Programming ...... 9 2.3 Factory Default Settings ...... 9 2.4 Main Page of Configuration...... 10
Chapter 3 Interface and Reading Mode Selection
3.1 Interface Selection ...... 11 3.2 Memory Function ...... 11 3.3 Reading Mode Selection ...... 12
Chapter 4 Communication Parameters
4.1 RS232 Mode Parameters ...... 13 4.2 Keyboard Wedge Mode Parameters..... 15 4.3 Output Characters Parameters ...... 17 4.4 Wand Emulation Mode Parameters...... 19
Chapter 5 Bar Codes & Others
5.1 Symbologies Selection ...... 20 5.2 UPC/EAN/JAN Parameters ...... 24 5.3 Code 39 Parameters ...... 26 5.4 Code 128 Parameters ...... 28 5.5 Interleave 25 Parameters ...... 30 5.6 Industrial 25 Parameters ...... 32 5.7 Matrix 25 Parameters ...... 34 5.8 CODABAR/NW7 Parameters ...... 36 5.9 Code 93 Parameters ...... 38 5.10 Code 11 Parameters ...... 40 5.11 MSI/PLESSEY Code Parameters ...... 42
1 5.12 Code 2 of 6 Parameters ...... 44 5.13 LCD 25 Parameters ...... 46 5.14 Telepen Parameters ...... 48 5.15 GS1 DataBar (RSS Code) ...... 50
Chapter 6 Miscellaneous Parameters
6.1 Language Selection ...... 52 6.2 Bar Code ID ...... 54 6.3 Reading Level ...... 57 6.4 Accuracy ...... 57 6.5 Buzzer Beep Tone ...... 57 6.6 LED Control ...... 57 6.7 Same Code Delay Reading lnterval ...... 58 6.8 Notebook Function ...... 58 6.9 Reverse Output Characters ...... 59 6.10 Set Up Deletion ...... 59 6.11 Set Up Insertion ...... 62 6.12 Set Up IR Sensor ...... 65
Chapter 7 Bluetooth Setup
7.1 Default Setting ...... 66 7.2 Memory Mode ...... 66 7.3 Sleep Mode ...... 66 7.4 Scanner Server Mode ...... 66 7.5 Scanner Cliver Mode ...... 66
Appendix
A. Decimal Value Tables ...... 67 B. ASCII Tables ...... 68 C. Function Key Tables ...... 72
Notice The manufacturer shall not be liable for technical or editorial errors or omissions contained herein; nor for incidental or consequential damages in connection with the furnishing,performance or use of use the publication.
2 Chapter 1 Description
1.1 General Thank you for purchasing this barcode scanner with an advanced and versatile decoder.The decoder works with variety of barcode types,reading devices, and computer interfaces.It discriminates over twenty different symbologies automatically.
This menu provides an easy way to configure the decoding options and interface selections by scan- ning bar codes listed in the menu.
FCC Approval
This device had been tested in accordance with the pro- cedures and in compliance with Part 15 Subpart B of FCC Rules. And keeps all requirments according ANSI C63.4 & FCC Part 15 B Regulation and CISPR22 Class B.
CE Standards
The CE mark as shown here indicates this product had been tested in accordance with the procedures given in European Council Directive 2004/108/EC and confirmed to comply with the Europe Standard EN55022:2006:Class B, EN 55024:1998+A1:2001+A2:2003,IEC61000-3-2:2006, IEC61000-3-3:1995+A1:2005,IEC61000-4-2:2001, IEC61000-4-3:2006,IEC61000-4-4:2004,IEC61000-4-5: 2006,IEC61000-4-6:2001,IEC61000-4-8:2001,IEC61000-4- 11:2004. LEGISLATION AND WEEE SYMBOL
This marking shown on the product or its literature, indicates that it should not be disposed with other households wastes at the end of its working life.To prevent possible harm to the environment or hu- man healthy from uncontrolled waste disposal, please separate this from other types of wastes and recyle it responsibly to promote the sustainable re- use of material resources. Household users should contact either the retailer where they purchased this product,or their local government office,for details of wher and how they can take this item fore environm entally safe recycling.Business users should contact their sup- plier and check the terms and conditions of the pur- chase
3 1.2 Introduction
The Decoder is an advanced and versatile decoding facility for barcoding systems .It works with variety of bar code types, reading devices, and computer interfaces. It discriminates about twenty different symbologies automatically.
This menu provide an easy way to config the decoding options and interface selections by scanning bar codes listed in the menu.
1.3 Codes Read
Codes Read ALL UPC/EAN/JAN , Code 39, Code 39 Full ASCII, Code 128, Interleave 25, Industrial 25, Matrix 25, CODABAR/NW7, Code 11, MSI/PLESSEY, Code 93, China Postage, Code32/Italian Pharmacy Others available upon request.
1.4 Installation
Unpacking – Remove the scanner from its packing and check it for damage. If the scanner was defected in transit, please contact your vendor immediately. Be sure that you keep the packing with all accessories contains in the package for your returning of service.
Connecting the scanner – Keyboard wedge/RS-232C/USB: Connect the 10-pins RS-45 male connector into the bottom of the scanner and you will hear a “click” when the connection is made.
4 Power supply for RS-232C scanner– There are 3 ways to supplying the power, use ex- ternal +5V power supply, use optional power cable (KBDC) which taking the power from KB wedge or if the host supports +5V power from pin 9.
Installing the scanner to the Host System – 1. Turn off the host system. 2. Connect the power if needed. 3. Connect to the proper port on the host system. 4. Turn on the host system.
Switching cable – Before removing the cable from the scanner, it is recommended that the power on the host system is off and the power supply has been disconnected from unit.
1. Find the small “Pin-hole” on the bottom of the unit. 2. Use a bended regular paperclip and insert the tip into the hole. 3. You will head a “click”, then gentle on the strain- relief of the cable and it will slide out of the scanner.
SG/LG Series
SD Series
5 1.5 Pin Assignment
A> Input Port for Mini Decoder DB 9 Male Pin No. Wand / CCD / Slot Reader Laser Scanner 1 N.C. S.O.S. 2 DATA DATA 3 N.C. N.C. 4 N.C. N.C. 5 N.C. TRIGGER 6 N.C. P. E. 7 GND GND 8 SHIELD SHIELD 9 +5V +5V 1 5
6 9
B> Output Port 1. PC Keyboard Output DIN 5 MALE DIN 5 FEMALE Pin No. Function Pin No. Function 1 HOST CLK 1 KB CLK 2 HOST DATA 2 KB DATA 4 GND 4 GND 5 Vcc(+5V) 5 Vcc(+5V)
1 3 3 1 4 5 5 4 2 2
MiniDIN 6 MALE MiniDIN 6 FEMALE Pin No. Function Pin No. Function 1 HOST DATA 1 KB DATA 3 GND 3 GND 4 Vcc 4 Vcc 5 HOST CLK 5 KB CLK 5 6 6 5 3 4 4 3 1 2 2 1
6 2. RS-232 Output DB 9 Female Pin No. Function 5 1 2 TXD 3 RXD 5 GND 9 6 7 CTS 8 RTS Power Lead Vcc (+5V)
3. WAND Emulation Output DB 9 Female Pin No. Function 5 1 2DATA 7 GND 9 6 9 Vcc (+5V)
4. ADB Interface MiniDIN 4 MALE MiniDIN 4 FEMALE Pin No. Function Pin No. Function 1 ADB 1 ADB 3 Vcc 3 Vcc 4 GND 4 GND 3 4 4 3
1 2 2 1
5. NEC 9801 Interface MiniDIN 8 MALE MiniDIN 8 FEMALE Pin No. Function Pin No. Function 1 RST 1 RST 2 GND 3 GND 3 HOST RDY 4 KB RDY 4 HOST DATA 5 KB DATA 5 RTY 4 RTY 8 +5V 5 +5V 7 7 6 8 8 6 3 5 5 3 1 2 2 1 4 4 7 Chapter 2 Configuration - General
2.1 Flow Chart
8 2.2 Loop of Programming
The philosophy of programming parameters has been shown on the flow chart of 2.1. Basically user should
1.Scan Start of Configuration. 2.Scan all necessary labels for parameters that meet applications. 3.Scan End of Configuration to end the programming. 4.To permanently save the settings you programmed ,just scan label for Save Parameters. 5.To go back to the Default Settings,just scan label for Set All Defaults.
2.3 Factory Default Settings
The factory default settings are shown with <> and bold in the following sections.You can make your own settings by following the procedures in this manual.If you want to save the settings permanently ,you should scan the label of "Save Parameters" in chapter 2.4,otherwise the settings will not be saved after the decoder power is off,and all settings will go back to previous settings.
By scanning "Set All Default" label,the settings will go back to the factory default settings.
9 2.4 Main Page of Configuration
Save Parameters
%$ + / 0
Recall Stored Parameters %$ + / 1
Set All Defaults
%$ + / 2
Start Configuration
%$ + / 3
End Configuration
%$ + / 4
Abort Configuration
%$ + / 6
Version Information
%$ + / 5
Save Parameters - The parameter settings will be saved permanently.
Recall Stored Parameters - Replace the current parameters by the parameters you saved last time.
Set All Defaults - Set all the parameters to the factory default settings.
Abort Configuration - Terminate current programming status.
Version Information - Display the decoder version information and date code.
10 Chapter 3 Interface and Reading Mode Selection
3.1 Interface Selection
%0 0 U 0 RS232 Mode
%0 0 U 8 WAND Emulation
%0 0 M2 USB Mode
%0 X O8
3.2 Memory Function
%0 X I 2
Disable
%0 X I 0
11 3.3 Reading Mode Selection
%0271 Trigger ON/OFF
%0270 Continuous/Trigger OFF
%0272 Testing
%0275 Continuous/Auto Power On
%0273 Flash
%0274 Flash/Auto Power On
%0276 Reserved1
%0277 Reserved2
%09F8 Reserved3
%09F9 Reserved4
%09FA Reserved5
%09FB
12 Ch.4 Communication Parameters
4.1 RS232 Communication Parameters
A> Set Up BAUD Rate
1200
2400 %0 Y 7 1
%0 Y 7 2 4800
<9600> %0 Y 7 3
%0 Y 7 7 19200
38400 %0 Y 7 4
%0 Y 7 5
B> Set Up Data Bits
7 Data Bits
%0 Y 8 0 <8 Data Bits>
%0 Y 8 8
C> Set Up Stop Bits
<1 Bit>
%0 Y O8 2 Bits
%0 Y O0
13 D> Set Up Parity
%0 Y N 7 Even
Odd %0 Y N 2
%0 Y N 3 Mark
Space %0 Y N 1
%0 Y N 0
E> Handshaking
RTS/CTS Enable
%0188
ACK/NAK Enable %0180
%0144
XON/XOFF Enable %0140
%0 3 K 4
%0 3 K 0
14 4.2 Keyboard Wedge Mode Parameters A> Terminal Type
%0ZF0 IBM PC/XT
IBM PS/2 25, 30 %0ZF1
%0ZF2 NEC 9800
Apple Desktop Bus(ADB) %0ZF3
%0ZF4 IBM 5550
IBM 122 Key (1) %0ZF5
%0ZF6 IBM 102 Key
IBM 122 Key (2) %0ZF7
%0ZF8 Reserved 1
Reserved 2 %0ZF9
%0ZFA Reserved 3
Reserved 4 %0ZFB
%0ZFC Reserved 5
%0ZFD
15 B> Upper/Lower Case
%0330 Upper Case
%0331 Lower Case
%0332
C> Capslock Detection
Enable
%0 X 8 8
%0 X 8 0
D> Send Character by ALT Method
Enable
%03O8
ON %03O0
%01K4
%01K0
16 4.3 Output Characters Parameters
A> Select Terminator
%7 S 2 + None
%7 S 7 + CR
%7 S 0 + LF
%7 S 1 + Space
%7 S 4 + HT(TAB)
%7 S 3 + STX-ETX
%7 S 5 +
17 B> Time-out Between Characters
<0 ms>
%0070 5 ms
%0071 10 ms
%0072 25 ms
%0073 50 ms
%0074 100 ms
%0075 200 ms
%0076 300 ms
%0077
18 4.4 Wand Emulation Mode Parameters
A> TTL Level Representation
%0 2 K 4 Bar Equals Low
%0 2 K 0
B> Scan Speed Selection
%0288 Slow
%0280
C> Output Format Selection
%0 2 O8 Output as Code 39 Full ASCII
%0 2 O0 Output as Original Code Format
%0XK4
19 Ch.5 Bar Codes & Others
5.1 Symbologies Selection
UPC-A
%0 A 4 4 OFF
UPC-E
%0 B O8 OFF
EAN-13/JAN-13/ISBN-13 %0 B O0
%0 A 2 2 OFF
EAN-8/JAN-8
%0 A 1 1 OFF
CODE 39
%0 E O8 OFF
CODE 128
%0 F O8 OFF
CODABAR/NW7
OFF %0 J O8
%0 J O0
20 Interleave 25
%0 GO8 OFF
Industrial 25 ON %0 GO0
%0 H O8
Matrix 25 ON %0 H O0
%0 I O8
CODE 93 ON %0 I O0
%0 K O8
CODE 11 ON %0 K O0
%0 L O8
China Postage ON %0 L O0
%0 MO8
MSI/PLESSEY ON %0 MO0
%0 N O8
%0 N O0
21 Code 2 of 6 ON
%0 P O8
%0 P O0 LCD25 ON
%0 QO8
Telepen ON %0 QO0
%0 T O8
Reserved5 ON %0 T O0
%0 R O8
%0 R O0 Reserved6 ON
%0 S O8
%0 S O0
22 RSS-14 ON
%0 U O8
RSS Limited ON %0 U O0
%0 V O8
RSS Expanded ON %0 V O0
%0 WO8
Select All Bar Codes %0 WO0
%1 A / +
23 5.2 UPC/EAN/JAN Parameters
A> Reading Type
UPCA=EAN13 ON
%0AK4 UPCA=EAN13
ISBN-10 Enable %0AK0
%0 B 8 8 ISBN-13
ISSN Enable %0 B 8 0
%0 B 4 4 ISSN
Decode with Supplement %0 B 4 0
%0 1 O0
Expand UPC-E Enable %0 1 O8
Expand UPC-E %0 B H 1
EAN8=EAN13 Enable %0 B H 0
EAN8=EAN13 %0 A 0 8
GTIN Format Enable %0 A O0
GTIN Format %0 X 4 4
%0 X 4 0
24 B> Supplementals Set Up
Transmit 2 Code %0 B 3 3
Transmit 5 Code %0 B 3 1
Transmit 2&5 Code %0 B 3 2
%0 B 3 0 C> Check Digit Transmission UPC-A Check Digit Transmission
OFF %0 A I 2
UPC-E Check Digit %0 A I 0 Transmission
OFF %0 B I 2
EAN-8 Check Digit %0 B I 0 Transmission
OFF %0 A 8 8
EAN-13 Check Digit %0 A 8 0 Transmission
OFF %0 A H 1
ISSN Check Digit %0 A H 0 Transmission
OFF
%0BK4
%0BK0
25 5.3 Code 39 Parameters
A> Type of Code
%0 E H 1 Full ASCII
%0 E H 0 Italian Pharmacy/Code 32
%0 E 8 0 Italian Pharmacy/ Code 32 ON
%0 E 8 8
B> Check Digit Transmission
%0 E M2 Calculate Check Digit & Transmit
Calculate Check Digit %0 E M6 & Not Transmit
%0 E M4
C> Output Start/Stop Character
Enable
%0 E 4 0
26 D> Decode Asterisk
Enable
%0 E 2 2
%0 E 2 0 E> Set Up Code Length
To set the fixed length: 1. Scan the "Begin" label of the desired set. 2. Go to the Decimal Value Tables in Appendix A, scan label(s) that represents the length to be read. 3. Scan the "Complete" label of the desired set. Repeat the steps 1 - 3 to set additional lengths.
%4 E 1 +
Fix Length (2 Sets Available) 1. 1st Set Begin 2. Decimal Value (Appendix A)
%4 E 0 0 3. 1st Set Complete
%4 E 0 1 1. 2nd Set Begin 2. Decimal Value (Appendix A)
%4 E 0 0 3. 2nd Set Complete
%4 E 0 2 Minimum Length 1. Begin 2. Decimal Value (Appendix A)
%2 + - / 3. Complete
%2 C 0 + 27 5.4 Code 128 Parameters
A> Reading Type
UCC/EAN-128 Enable
%0 F 4 0 B> Check Digit Transmission Do Not Calculate Check Digit
%0 F N 1 Calculate Check Digit & Transmit
%0 F N 5
C> Append FNC2 ON
%0 F 8 8
%0 F 8 0 D> Set Up Code Length
To set the fixed length: 1. Scan the "Begin" label of the desired set. 2. Go to the Decimal Value Tables in Appendix A, scan label(s) that represents the length to be read. 3. Scan the "Complete" label of the desired set.
Repeat the steps 1 - 3 to set additional lengths.
28
%4 F 1 +
Fix Length (2 Sets Available) 1. 1st Set Begin 2. Decimal Value (Appendix A)
%4 F 0 0 3. 1st Set Complete
%4 F 0 1
1. 2nd Set Begin 2. Decimal Value (Appendix A)
%4 F 0 0 3. 2nd Set Complete
%4 F 0 2
Minimum Length 1. Begin 2. Decimal Value (Appendix A)
%2 + - / 3. Complete
%2 C 1 +
29 5.5 Interleave 25 Parameters
A> Check Digit Transmission
%0 GN 3 Calculate Check Digit & Transmit
%0 GN 7 Calculate Check Digit & Not Transmit
%0 GN 5
B> Set Up Number of Character
%0 G8 8 Odd
%0 G8 0
C> Brazilian Banking Code
%0 G4 0 Enable
%0 G4 4
30 D> Set Up Code Length
To set the fixed length: 1. Scan the "Begin" label of the desired set. 2. Go to the Decimal Value Tables in Appendix A, scan label(s) that represents the length to be read. 3. Scan the "Complete" label of the desired set.
Repeat the steps 1 - 3 to set additional lengths.
%4 G1 +
Fix Length (2 Sets Available) 1. 1st Set Begin 2. Decimal Value (Appendix A)
%4 G0 0 3. 1st Set Complete
%4 G0 1
1. 2nd Set Begin 2. Decimal Value (Appendix A)
%4 G0 0 3. 2nd Set Complete
%4 G0 2
Minimum Length 1. Begin 2. Decimal Value (Appendix A)
%2 + - / 3. Complete
%2 C 2 +
31 5.6 Industrial Parameters
A> Reading type
IATA25 Enable
%0 H 4 4
%0 H 4 0 B> Check Digit Transmission
Calculate Check Digit %0HN3 & Transmit
%0HN7 Calculate Check Digit & Not Transmit
%0HN5
C> Set Up Code Length
To set the fixed length: 1. Scan the "Begin" label of the desired set. 2. Go to the Decimal Value Tables in Appendix A, scan label(s) that represents the length to be read. 3. Scan the "Complete" label of the desired set.
Repeat the steps 1 - 3 to set additional lengths.
32
%4 H 1 +
Fix Length (2 Sets Available)
1. 1st Set Begin 2. Decimal Value (Appendix A)
%4 H 0 0 3. 1st Set Complete
%4 H 0 1
1. 2nd Set Begin 2. Decimal Value (Appendix A)
%4 H 0 0 3. 2nd Set Complete
%4 H 0 2
Minimum Length 1. Begin 2. Decimal Value (Appendix A)
%2 + - / 3. Complete
%2 C 3 +
33 5.7 Matrix 25 Parameters
A> Check Digit Transmission
%0 I N 3 Calculate Check Digit & Transmit
%0 I N 7 Calculate Check Digit & Not Transmit
%0 I N 5
B> Set Up Code Length
To set the fixed length: 1. Scan the "Begin" label of the desired set. 2. Go to the Decimal Value Tables in Appendix A, scan label(s) that represents the length to be read. 3. Scan the "Complete" label of the desired set.
Repeat the steps 1 - 3 to set additional lengths.
34
%4 I 1 +
Fix Length (2 Sets Available) 1. 1st Set Begin 2. Decimal Value (Appendix A)
%4 I 0 0 3. 1st Set Complete
%4 I 0 1
1. 2nd Set Begin 2. Decimal Value (Appendix A)
%4 I 0 0 3. 2nd Set Complete
%4 I 0 2
Minimum Length 1. Begin 2. Decimal Value (Appendix A)
%2 + - / 3. Complete
%2 C 4 +
35 5.8 CODABAR/NW7 Parameters
A> Set Up Start/Stop Characters Upon Transmission ON
%0 J H 0
B> Transmission Type of Start/Stop
A Start %0 4 F F
%0 4 V 1 A Stop
B Start %0 4 F 1
%0 4 V 2 B Stop
C Start %0 4 F 2
%0 4 V 4 C Stop
D Start %0 4 F 4
D Stop %0 4 V 8
%0 4 F 8
36 C> Set Up Code Length
To set the fixed length: 1. Scan the "Begin" label of the desired set. 2. Go to the Decimal Value Tables in Appendix A, scan label(s) that represents the length to be read. 3. Scan the "Complete" label of the desired set.
Repeat the steps 1 - 3 to set additional lengths.
%4 J 1 +
Fix Length (2 Sets Available) 1. 1st Set Begin 2. Decimal Value (Appendix A)
%4 J 0 0 3. 1st Set Complete
%4 J 0 1
1. 2nd Set Begin 2. Decimal Value (Appendix A)
%4 J 0 0 3. 2nd Set Complete
%4 J 0 2
Minimum Length 1. Begin 2. Decimal Value (Appendix A)
%2 + - / 3. Complete
%2 C 5 +
37 5.9 Code 93 Parameters
A> Check Digit Transmission
%0 K N 4
Do Not Calculate Check Digit
%0 K N 3
B> Set Up Code Length
To set the fixed length: 1. Scan the "Begin" label of the desired set. 2. Go to the Decimal Value Tables in Appendix A, scan label(s) that represents the length to be read. 3. Scan the "Complete" label of the desired set.
Repeat the steps 1 - 3 to set additional lengths.
38
%4 K 1 +
Fix Length (2 Sets Available) 1. 1st Set Begin 2. Decimal Value (Appendix A)
%4 K 0 0 3. 1st Set Complete
%4 K 0 1
1. 2nd Set Begin 2. Decimal Value (Appendix A)
%4 K 0 0 3. 2nd Set Complete
%4 K 0 2
Minimum Length 1. Begin 2. Decimal Value (Appendix A)
%2 + - / 3. Complete
%2 C 6 +
39 5.10 Code 11 Parameters
A> Check Digit Transmission
%0 L N 3 Calculate Check 1 Digit & Transmit
%0 L N 7 Calculate Check 1 Digit & Not Transmit
%0 L N 5 Calculate Check 2 Digits & Transmit
%0 L N 6 Calculate Check 2 Digits & Not Transmit
%0 L N 4
B> Set Up Code Length
To set the fixed length: 1. Scan the "Begin" label of the desired set. 2. Go to the Decimal Value Tables in Appendix A, scan label(s) that represents the length to be read. 3. Scan the "Complete" label of the desired set.
Repeat the steps 1 - 3 to set additional lengths.
40
%4L1+
Fix Length (2 Sets Available) 1. 1st Set Begin 2. Decimal Value (Appendix A)
%4L00 3. 1st Set Complete
%4L01
1. 2nd Set Begin 2. Decimal Value (Appendix A)
%4L00 3. 2nd Set Complete
%4L02
Minimum Length 1. Begin 2. Decimal Value (Appendix A)
%2 + - / 3. Complete
%2 C 7 +
41 5.11 MSI/PLESSEY Code Parameters
A> Check Digit Transmission
Do Not Calculate Check Digit
%0NN3 Calculate Check Digit & Transmit
%0NN7
%0NN5
B> Set Up Code Length
To set the fixed length: 1. Scan the "Begin" label of the desired set. 2. Go to the Decimal Value Tables in Appendix A, scan label(s) that represents the length to be read. 3. Scan the "Complete" label of the desired set.
Repeat the steps 1 - 3 to set additional lengths.
42
%4 N 1 +
Fix Length (2 Sets Available) 1. 1st Set Begin 2. Decimal Value (Appendix A)
%4 N 0 0 3. 1st Set Complete
%4 N 0 1
1. 2nd Set Begin 2. Decimal Value (Appendix A)
%4 N 0 0 3. 2nd Set Complete
%4 N 0 2
Minimum Length 1. Begin 2. Decimal Value (Appendix A)
%2 + - / 3. Complete
%2 C 9 +
43 5.12 Code 2 of 6 Parameters
A> Check Digit Transmission
%0 P N 3 Calculate Check Digit & Transmit>
%0 P N 7 Calculate Check Digit & Not Transmit
%0 P N 5
B> Set Up Code Length
To set the fixed length: 1. Scan the "Begin" label of the desired set. 2. Go to the Decimal Value Tables in Appendix A, scan label(s) that represents the length to be read. 3. Scan the "Complete" label of the desired set.
Repeat the steps 1 - 3 to set additional lengths.
44
%4 P 1 +
Fix Length (2 Sets Available) 1. 1st Set Begin 2. Decimal Value (Appendix A)
%4 P 0 0 3. 1st Set Complete
%4 P 0 1
1. 2nd Set Begin 2. Decimal Value (Appendix A)
%4 P 0 0 3. 2nd Set Complete
%4 P 0 2
Minimum Length 1. Begin 2. Decimal Value (Appendix A)
%2 + - / 3. Complete
%2 C B +
45 5.13 LCD25 Parameters
A> Check Digit Transmission
%0 QN 3 Calculate Check Digit & Transmit
%0 QN 7 Calculate Check Digit & Not Transmit
%0 QN 5
B> Setup Code Length
To set the fixed length: 1. Scan the "Begin" label of the desired set. 2. Go to the Decimal Value Tables in Appendix A, scan label(s) that represents the length to be read. 3. Scan the "Complete" label of the desired set.
Repeat the steps 1 - 3 to set additional lengths.
46
%4 Q1 +
Fix Length (2 Sets Available) 1. 1st Set Begin 2. Decimal Value (Appendix A)
%4 Q0 0 3. 1st Set Complete
%4 Q0 1
1. 2st Set Begin 2. Decimal Value (Appendix A)
%4 Q0 0 3. 2nd Set Complete
%4 Q0 2
Minimum Length 1. Begin 2. Decimal Value (Appendix A)
%2 + - / 3. Complete
%2CC+
47 5.14 Telepen Parameters
A> Type of Code
Compressed Numeric %0 T 8 0 Mode
%0 T 8 8
B> Check Digit Transmission
Do Not Calculate Check Digit
%0 T N 3 Calculate Check Digit & Transmit
%0 T N 5
C> Set Up Code Length
To set the fixed length: 1. Scan the "Begin" label of the desired set. 2. Go to the Decimal Value Tables in Appendix A, scan label(s) that represents the length to be read. 3. Scan the "Complete" label of the desired set.
Repeat the steps 1 - 3 to set additional lengths.
48
%4 T 1 +
Fix Length (2 Sets Available) 1. 1st Set Begin 2. Decimal Value (Appendix A)
%4 T 0 0 3. 1st Set Complete
%4 T 0 1
1. 2nd Set Begin 2. Decimal Value (Appendix A)
%4 T 0 0 3. 2nd Set Complete
%4 T 0 2
Minimum Length 1. Begin 2. Decimal Value (Appendix A)
%2 %+ - / 3. Complete
%2 C F +
49 5.15 GS1 Databar(RSS Code)
A> RSS-14 Parameters
Transmit Check Digit
%0UN7 Do Not Transmit Check Digit
%0 U 8 8 Do Not Transmit Application ID
Transmit Symbology ID %0 U 8 0
%0 U 4 4
%0 U 4 0 B> RSS Limited Parameters
%0 V N 7 Do Not Transmit Check Digit
%0 V N 5
50
%0 V 8 8 Do Not Transmit Application ID
Transmit Symbology ID %0 V 8 0
%0 V 4 4
Do Not Transmit Symbology ID
%0 V 4 0
C> RSS Expanded Parameters
Transmit Symbology ID
%0 W44
%0 W40
51 Ch.6 Miscellaneous Parameters 6.1 Language Selection
%0 Z V 0 UK English
%0 Z V 1 Italian
%0 Z V 2 Spanish
%0 Z V 3 French
%0 Z V 4 German
%0 Z V 5 Swedish
%0 Z V 6 Switzerland
%0 Z V 7 Hungarian
%0 Z V 8 Japanese
%0 Z V 9
52 Belgium
%0 Z V A Portuguese
%0 Z V B Denmark
%0 Z V C Netherlands
%0 Z V D Turkey
%0 Z V E Reserved2
%0 Z V F
53 6.2 Bar Code ID
ON
%0 0 H 1
%0 0 H 0
Default
%913+
With this function ON, a leading character will be added to the output string while scanning code, user may refer to the following table to know what kind of bar code is being scanned.
Please refer to the table below for matching code ID of codes read in.
Code Type ID Code Type ID UPC-A A UPC-E B EAN-8 C EAN-13 D CODE 39 E CODE 128 F Interleave 25 G Industrial 25 H Matrix 25 I Codabar/NW7 J CODE 93 K CODE 11 L China Postage M MSI/PLESSEY N Code 2 of 6 P LCD25 Q Telepen T RSS-14 U RSS Limited V RSS Expanded W
User Define Code ID
To set the code ID: 1. Scan the symbologies label. 2. Go to the ASCII Tables in Appendix B, scan label that represents the desired code ID. Note: User define code ID will override default value. Program will not check the conflict. It is possible to have more than two symbologies which have same code ID.
54 UPC-A
%9 1 A + UPC-E
EAN-13/JAN-13 %9 1 B +
%9 1 Y + EAN-8/JAN-8
CODE 39 %9 1 Z +
%9 1 E + CODE 128
CODABAR/NW7 %9 1 F +
%9 1 J + Interleave 25
Industrial 25 %9 1 G+
%9 1 H + Matrix 25
CODE 93 %9 1 I +
%9 1 K + CODE 11
China Postage %91L+
%9 1 M+ MSI/PLESSEY
%9 1 N +
55 Code 2 of 6
%9 1 P + Telepen
%91T+
LCD25
%91Q+ RSS-14
%91U+
RSS Limited
%91V+
RSS Expanded
%91W+
Reserved5
%9 1 R +
Reserved6
%9 1 S +
56 6.3 Reading Level
Bar Equals High
%0 3 I 2
6.4 Accuracy %0 3 I 0
<1 Time>
%0130 2 Times
3 Times %0131
%0132 4 Times
6.5 Buzzer Beep Tone %0133
%0 1 J 3 Medium
Low %0 1 J 2
%0 1 J 1 Off
%0 1 J 0
6.6 LED Control(SV700 only)
%09O8 OFF
%09O0
57 6.7 Sensitivity of Continuous Reading Mode
A> Quick Setting:
Slow %0388
%0380
B> Same Code Delay Reading Interval
Following code sequences represent the length of time before a barcode can be rescanned at continuous and flash reading mode. The value can be defined from 1-50 and they represent 100ms to 5 seconds in 100ms interval.Default value is 3 (0.3 seconds).
To setup same code delay reading interval:
1.Scan the "Begin" label 2.Go the Decimal Value Tables in Appendix A, Scan label(s),that represents the same code delay reading interval.They are ranged form 1-50.One step is represented 0.1second.So the interval is from 0.1 to 5 seconds. 3.Scan the "Complete" label
Repeat the steps 1-3 to set time out of same symbol 1.Begin 2.Decimal Value (1-50) (Appendix A)
%30000 3.Complete
%30001 6.8 Notebook Function Enable
%0340 58 6.9 Reverse Output Characters
%0 3 H 0 Enable
6.10 Setup Deletion %0 3 H 1
To setup the deletion of output characters:
1. Scan the label of the desired set below. 2. Scan the label of the desired symbology. 3. Go to the Decimal Value Tables in Appendix A, scan label(s) that represents the desired position to be deleted. 4. Scan the "Complete" label of "Character Position to be Deleted". 5. Go to the Decimal Value Tables in Appendix A, scan label(s) that represents the number of characters to be deleted. 6. Scan the "Complete" label of "Number of Characters to be Deleted".
Repeat the steps 1 - 6 to set additional deletion.
A> Select Deletion Set Number
1. 1st Set
%800+ 2. 2nd Set
3. 3rd Set %801+
%802+ 4. 4th Set
5. 5th Set %803+
%804+ 6. 6th Set
%805+ 59 B> Symbologies Selection
UPC-A
%8 1 A + UPC-E
EAN-13/JAN-13/ISBN-13 %8 1 B +
%8 1 Y + EAN-8/JAN-8
CODE 39 %8 1 Z +
%8 1 E + CODE 128
CODABAR/NW7 %8 1 F +
%8 1 J + Interleave 25
Industrial 25 %8 1 G+
%8 1 H + Matrix 25
CODE 93 %8 1 I +
%8 1 K + CODE 11
China Postage %81L+
%8 1 M+ MSI/PLESSEY
%8 1 N +
60 Code 2 of 6
Telepen %8 1 P +
%81T+ LCD25
RSS-14 %81Q+
%81U+ RSS Limited
RSS Expanded %81V+
%81W + All Codes
None %8 1 S +
%814+
C> Character Position to be Deleted
1. Decimal Value (Appendix A) 2. Complete
%820+
D> Number of Characters to be Deleted
1. Decimal Value (Appendix A) 2. Complete
%830+
61 6.11 Setup Insertion
To setup the insertion of output characters:
1. Scan the label of the desired set. 2. Scan the label of the desired symbology. 3. Go to the Decimal Value Tables in Appendix A, scan label(s) that represents the desired position to be inserted. 4. Scan the "Complete" label of "Character Position to be Inserted". 5. Go to the ASCII Tables in Appendix B or Function Key Tables in Appendix C, scan label(s) that represents the desired characters to be inserted. 6. Scan the "Complete" label of "Characters to be Inserted".
Repeat the steps 1 - 6 to set additional insertion.
A> Select Insertion Set Number
1. 1st Set
%500+ 2. 2nd Set
3. 3rd Set %501+
%502+ 4. 4th Set
5. 5th Set %503+
%504+ 6. 6th Set
%505+
62 B> Symbologies Selection
UPC-A
%5 1 A + UPC-E
EAN-13/JAN-13/ISBN-13 %5 1 B +
%5 1 Y + EAN-8/JAN-8
CODE 39 %5 1 Z +
%5 1 E + CODE 128
CODABAR/NW7 %5 1 F +
%5 1 J + Interleave 25
Industrial 25 %5 1 G+
%5 1 H + Matrix 25
CODE 93 %5 1 I +
%5 1 K + CODE 11
China Postage %51L+
%5 1 M+ MSI/PLESSEY
%5 1 N +
63 Code 2 of 6
Telepen %51P+
%51T+ LCD25
RSS-14 %51Q+
%51U+ RSS Limited
RSS Expanded %51V+
%51W+ All Codes
None %5 1 S +
%514+
C> Character Position to be Inserted
1. Decimal Value (Appendix A) 2. Complete
%520+
D> Characters to be Inserted
1. ASCII Table (Appendix B) 2. Complete
%530+
64 6.12 Setup IR Sensor (LG303 only)
%0 X H 0
Enable
%0 X H 1
65 Ch.7 Bluetooth Setup
7.1 Default Setting
%+$0001$
7.2 Memory Mode ON
%+$0002$
%+$0003$
7.3 Sleep Mode
%+$0004$
OFF
%+$0005$
7.4 Scanner Server Mode ON /Scanner Client Mode Off
%+$0006$
7.5
%+$0007$
66 Appendix A Decimal Value Table
0
1
2
3
4
5
6
7
8
9
67 Appendix B ASCII Table
NULL SOH
00 STX 01
ETX02 EOT
03 ENQ 04
ACK05 BEL
06 BS 07
HT08 LF
09 VT 0A
FF0B CR
0C SO 0D
SI0E DLE
0F DC1 10
DC211 DC3
12 DC4 13
NAK14 SYN
15 ETB 16
CAN17 EM
18 SUB 19
ESC1A FS
1B GS 1C
RS1D US
1E 1F
68 SPACE !
20 " 21
#$22
23 % 24
&'25
26 ( 27
)*28
29 + 2A
,-2B
2C . 2D
/02E
2F 1 30
2331
32 4 33
5634
35 7 36
8937
38 : 39
;<3A
3B = 3C
>?3D
3E 3F
69 @A
40 B 41
CD42
43 E 44
FG45
46 H 47
IJ48
49 K 4A
LM4B
4C N 4D
OP4E
4F Q 50
RS51
52 T 53
UV54
55 W 56
XY57
58 Z 59
[\5A
5B ] 5C
^_5D
5E 5F
70 `a
60 b 61 cd62
63 e 64 fg65
66 h 67 ij68
69 k 6A lm6B
6C n 6D op6E
6F q 70 rs71
72 t 73 uv74
75 w 76 xy77
78 z 79
{|7A
7B } 7C
~7D DEL
7E 7F
71 Appendix C Function Key Table
F1 F2
C0 C1 F3
C2 F4 F5
C3 C4 F6
C5 F7 F8
C6 C7 F9
C8 F10 F11
C9 CA F12
CB Insert Delete
CC CD Home
CE Page Up Page Down
CF D0 End
D1 Left Right
D2 D3 Up
D4 Down
D5 72 save Parameters
%$ + / 0
Recall Stored Parameters %$ + / 1
Set All Defaults %$ + / 2
Start Configuration
%$ + / 3
End Configuration
%$ + / 4
Abort Configuration
%$ + / 6
Version Information
%$ + / 5
Ver 3.9 0145-85E00M1