Occupational Exposure to Asbestos in the Drywall Taping Process

Total Page:16

File Type:pdf, Size:1020Kb

Occupational Exposure to Asbestos in the Drywall Taping Process Studies of airborne asbestos fiber concentrations associated with various operations of the drywall tapin process have been undortaken in the province of Alberta, Canada. The results show that mixing, sanding an~ sweeping created high levels of airborne asbestos dust. The measured concentrations were-frequently in exces of occupational health standards. Sanding in particular was assessed the most hazardous op.eration. The resu1/ are discussed in light of present and proposed Occupational Health Standards, and in terms of its implications f~~ other workers, household contacts, and cc:>nsumer's risk. Measures to reduce and control the health hazards associated with the process are described. Occupational exposure to asbestos in the drywall taping process 11 DAVE K. VERMA A and CHARLES G. MIDDLETON AOccupational Health Program, McMaster University, Hamilton, Ontario, Canada L8N 325; 80ccupational Health & Safety Division, Alberta Worker's Health Safety & Compensation, Edmonton, Alberta Canada T5K 2J6 PLAINTIFF'S i EXHIBIT l SoA 5'151 introduction Occupational exposure to asbestos is associated with a risk first study may not be indicative of typical occupational of asbestosis, mesothelioma, an excess risk of cancer of the exposure of the drywall taping process. 4 lung and possible cancers at other sitesY- ) These asbestos 5 related diseases have been found in mines and mills,( ) in Data is also lacking on the health status of this group of 6 manufacturing industries,( ) and in the use of asbestos workers exposed to asbestos. One published report of 7 products such as insulation in construction industries. ( ) The medical examinations conducted on a group of 69 tapers magnitude of the occupational health problem associated showed X-ray abnormalities characteristic of asbestos 1 with asbestos exposure is enormous. The relative risk of exposure in 37 out of 69 filmsY l Two thirds of this group lung cancer among asbestos workers has been demonstrated had an exposure of 10 years duration or longer, and 61 were 9 from epidemiological studies to range between 1.4 and 3.3 smokers or ex-smokers. A recent clinical report( ) on the for miners and millers, 1.0 to 13.7 for production and same group of drywall workers, but with an expanded manufacturing industry workers and 5.1 to 8.3 for cohort (114), showed radiological evidence for pulmonary 4 insulators. ( ) The risk due to cigarette smoking and asbestos asbestosis in 40.9% of the cases examined. This compares to 9 exposure has been recognized to be multiplicative rather 48.5% among insulators.( ) Consequently drywall tapers than additive so that an asbestos worker who smokes has an appear to have similar exposure as insulators. In light of this extremely high risk oflung cancers. An asbestos worker who it is interesting to note that tapers in Alberta are not under smokes has a 92 times greater risk than a wor.ker who neither medical surveillance whilst insulators, who are considered 3 smokes nor works with asbestos. ( ) asbestos workers, are. To our knowledge this lack of medical ~urveillance for tapers as asbestos workers exists in Very little has been reported in the literature about the potential occupational health risk to drywall taping other provinces of Canada and most parts of the U. S. workers. A review of the literature revealed only two Because of the above mentioned concerns we initiated, in independent studies dealing with the occupational exposure 1975, an investigation in the province of Alberta of the to asbestos in the taping process. In the first study results of drywall taping process. This operation was known to thirty-nine air samples taken at the various operations of the involye the use of an asbestos containing compound. process were discussed. (B) Generally high (mean values of 2.6 Specifically the aim of this study was to assess quantitatively to 47.2 fibers/cc for specific operations) airborne asbestos the occupational exposure· to asbestos in this group of levels were noted. This earlier report has recently been workers. Our findings are summarized in this report. 9 published in an expanded version.( ) In the second study, conducted on a similar sample size, much lower (mostly between 0.5 and 3.5 fibers/cc) exposure levels were reported. (IO) The latter authors inferred that the results of the the drywall taping process In the construction of a co'minercial building, wallboards are fixed to metal studs with screws, while in residential The opinions and suggestions contained In this report are the private views of the authors and are not to be construed as official or houses the gyp.sum wallboards are nailed onto the wooden representing the views of Alberta Worker's Health Safety and studs. The resulting joints, as well as screw and nail Compensation. indentations, are finished by taping. Copyright 1980, American Industrial Hygiene Assoolallon 264 Am. Ind. Hyg. Assoc. J, (41) April, 1980 of asbestos (chrysotile), in the past they have contained 'x/ng 9 e dry joint compound powder is normally contained in much higher proportions of asbestos. ( l Three types of joint er bags. The bag is slit open by a knife and the powder compounds are available: taping, topping, and all purpose, mped into a container. Water is then added according to all of which contain asbestos. Taping joint compound is manufacturer's directions and the compound mixed by applied in one or two coats and is designed for strength. The ns of a portable electric drill equipped with a mud and topping or finishing variety is generally applied in the final t mixer. Some joint compound is sold· as a paste coat and has better finishing qualities. The all purpose compound is a compromise formula that can be used for erred to as "premix") and only a small amount of water is both taping and finishing purposes. Asbestos is used in these uired. The prepared mixture in its putty like form after joint compounds because it serves several functions ting is referred to as mud. The time spent mixing in a including controlling shrinkage and cracking when the mud rking day is short. It usually takes 5 to 10 min. to mix a dries, and providing good workability in troweling and ch and in most instances 09e to three batches are sanding. uired daily. //cation materials and methods joint compound (mud) is placed on the bottom side ofa site description er tape and is applied to cover the joints between the During 1975 to 1977 several work-sites were visited sum boards and allowed to dry. Subsequently, this throughout the province and eight of them were evaluated pound is also applied on the front side of the tape and to by air sampling. Work schedules and the time spent at wand nail indentations. A major portion (65-70%) of various operations at worksites differed widely. In small working day is spent in this operation. companies, the owner often worked out of his home and undertook all the work himself. Companies with larger ding workforces of 15-20 employees had individual workers e joints and indentations are sanded between each performing specific tasks such as sanding on a full-time lication of mud, with the major amount of sanding being basis . .ried out after the final coat. Three to four coats of mud ·· usually applied. Sanding operations normally involve Following these initial surveys we conducted a more er hand sanding or pole sanding. Hand sanding is detailed study over a three-month period at a downtown site ried out with a hand-held, abrasive paper, covered in Edmonton where a multi-storied hotel was under ding block. In pole sanding, the sanding block is at the construction. This survey of a large commercial site was of a long pole. Generally speaking most of the sanding is begun in January, 1978. ded out by pole sanding, We estimate that 25-30% of Both the residential and commercial site studies al time is spent in this operation. concentrated on the evaluation of worker's exposure to airborne asbestos dust. The potentially hazardous effects of eeping and cleanup other components of dust such as nuisance particulates, debris and the dust accumulated on the floor resulting crystalline silica, chemicals, etc., were not examined in the m the mixing, application and sanding operations is same detail. It was felt that asbestos posed the most erally cleaned up by dry sweeping. In many instances, significant hazard and control measures applied for asbestos ecially in cases of commercial building and large exposure would be equally effective against other hazardous jects, this operation is carried out by general laborers. particulates. ever, it was generally found to be part of the work edule of employees of small companies working on methodology ential construction projects. 1. Airborne asbestos dust samples were taken by using open-face filter cassettes, loaded with 37 mm 0.8 omposition of joint compounds micron pore size Millipore, Type AA membrane composition of joint compounds varies from filters. Air was drawn through the filter papers by a nufacturer to manufacturer. During the study period portable pump at a flow rate of 2.0 liters/min. The st joint compounds were said to contain between 3 - 6% sampling period was guided by two factors - · chrysotile asbestos by weight. The remainder was concentrations expected and duration of posed of limestone or dolomite, talc, clay, mica, starch operations. Most sampling assemblies were · fungicide, A typical joint compound formulation, based attached to the worker's lapels. To obtain area or he information obtained from the manufacturers, was: location samples assemblies were attached to Limestone , , , , , ............. , .. , 80 - 85% portable stands. The pump was calibrated before · Clay, talc, mica ...... , ......... , . , S - 10% each use by a soap bubble meter.
Recommended publications
  • Fire Protection Application Guide Armacell's Products for Passive Fire Protection
    FIRE PROTECTION APPLICATION GUIDE ARMACELL'S PRODUCTS FOR PASSIVE FIRE PROTECTION Tel.: +49 25 17 60 30 [email protected] www.armacell.eu 02 | Fire protection application guide Foreword “Nine dead in house fire.” Fortunately we don’t read this or similar headlines every day. Nevertheless, around 4,000 people die in fires every year in the EU member countries. In many cases, deaths, injuries and major damage to buildings can be prevented if the fire protection requirements are implemented correctly. Therefore, passive fire protec- tion in buildings aims to design, construct, modify and maintain build- ings in such a way that the outbreak of a fire and the spread of flames and smoke (fire spread) are prevented. And, if a fire does occur, it must be possible to rescue people and animals and carry out fire-fighting operations effectively. In terms of fire protection, building service equipment, such as pipe- work and ventilation systems, represents a particular weak point. Pipe- and ductwork passes through separating building elements (walls and ceilings), stairwells and corridors, and thus forms a path along which flames and smoke can spread. In the event of a fire, pipe- and ductwork has a significant impact on safety in buildings and can soon pose a seri- ous threat. The risk potential rises with the number of pipes and their various tasks, thicknesses, materials and media. Therefore, in order to achieve the necessary fire protection targets, service penetrations in separating building elements must be sealed off. These fire protec- tion measures can be carried out in accordance with the less strin- gent requirements of the MLAR (state building regulations) or with an approval.
    [Show full text]
  • Case Study: Asbestos Joint Compound on Drywall/Sheetrock $100,000.00 Savings
    CASE STUDY: ASBESTOS JOINT COMPOUND ON DRYWALL/SHEETROCK $100,000.00 SAVINGS SCOPE OF SERVICES: AET was contracted by a not-for-profit senior adult community facility to provide asbestos contracting services prior to planned demolition of one of their outdated buildings. An EPA NESHAP inspection of the building had previously identified 24,000 SF of asbestos containing joint compound associated with non-asbestos drywall on the interior walls of the building. The asbestos building inspector had made a recommendation to remove the joint compound and associated drywall prior to demolition. AET was asked to provide a competitive bid for asbestos work along with two other asbestos contractors. AET EXPERIENCE: Joint compound or mud is used to seal joints/seams of the drywall. After application and drying the compound is sanded before being painted. Sanding can create an inhalation hazard from the dust release. Joint compound used before 1980 can contain asbestos. OSHA regulates disturbance/exposure to joint compound and requires this building material to be analyzed separately from the drywall by PLM. The EPA regulates disposal of drywall/joint compound and allows for this combined material to be composited into a single matrix. When analyzed as separate layers by OSHA, the drywall itself rarely contains asbestos and the joint compound where asbestos is found usually contains between 2-4% chrysotile asbestos. However, when analyzed as a composite per EPA protocol, the combined building material (2 layers) rarely exceeds >1% criteria to be defined as ACM. ABATEMENT REQUIREMENTS/COST SAVINGS: AET informed the potential new client that the drywall/joint compound did not have to be removed prior to demolition.
    [Show full text]
  • Sheetrock Plaster of Paris J928
    ® Plaster of Paris For patching interior walls and ceilings Description SHEETROCK Plaster of Paris is a fast-setting material used to repair ▪ For drywall and plaster surfaces holes and cracks in drywall and plaster walls and ceilings. It dries hard within 30 minutes. SHEETROCK Plaster of Paris may also be used ▪ Also ideal for molding and casting for casting, modeling or sculpting forms. ▪ Advantages Sets hard in 30 minutes Ideal for patching. SHEETROCK Plaster of Paris is the solution to ▪ For interior use only interior drywall and plaster surface problems. Patching both holes and cracks is easy and fast. Fast setting. SHEETROCK Plaster of Paris is easy to work with and hardens in only 30 minutes. Economical. Mix only the amount of SHEETROCK Plaster of Paris you need to use for each application. For molding and casting. SHEETROCK Plaster of Paris is formulated so that it provides excellent molding and casting properties Directions Mixing—Use cool, clean water and clean equipment; mix powder and water in proportions shown below. Mix to the consistency of a smooth paste. Do not overthin. Avoid mixing more material than can be used in 15 minutes. Mixing Proportions—Mix powder thoroughly into water until completely wet. The initial mix should be slightly thicker or heavier than the desired working consistency. Mix until smooth. Let this initial mix soak for approximately one minute. (Note: The cooler the conditions, the longer the material must soak.) Remix approximately one minute, adding water to achieve the desired working consistency. Do not mix with other compounds in wet or dry form.
    [Show full text]
  • The Sound Design Guide
    The Sound Design Guide a transparent resource for sound & fire information get your LEED on! Scan this code to access our LEED credit calculator and score points for your project! if your walls could talk they would ask for us Architects and specifi ers face many design challenges, knowing what your walls really want shouldn’t be one of them. Walls and ceilings are not something just to hold up paint, they play a critical role in your building design. As a manufacturer, we have taken great strides in simplifying this part of the building envelope by providing new comprehensive tools and rich online resources to you, the architect and specifi er. Our product specifi cations and sustainability tools, available at www.PABCOgypsum.com and ARCAT, have been paired with new continuing education courses that cover everything from sound and acoustic challenges to discussions related to new 2015 industry standards. Meet your design goals with ease. Be it our trusted FLAME CURB®, light-weight LITECORE®, protective PABCO GLASS® or our award winning QuietRock®; we have what the job demands. what the job demands PABCO® Gypsum technical services: 866.282.9298 www.PABCOgypsum.com QuietRock® acoustical products: 800.797.8159 www.QuietRock.com get your LEED on! Scan this code to access our LEED credit calculator and score points for your project! if your walls could talk they would ask for us Architects and specifi ers face many design challenges, knowing what your walls really want shouldn’t be one of them. Walls and ceilings are not something just to hold up paint, they play a critical role in your building design.
    [Show full text]
  • Forcefield® Fireguard E-84® Intumescent Paint for Gypsum/ Wood/ OSB
    ForceField® FireGuard E-84® Intumescent Paint For Gypsum/ Wood/ OSB Application Conditions Substrates & Surface Preparation General Prior to application surfaces need to be cleaned by removing Generic Type Water-based intumescent coating designed for the fire all oil, grease or any loose particles that may interfere with protection of gypsum and wood. the bond of ForceField® FireGuard®. It is highly Description Thin film intumescent coating that creates a fire retardant recommended to prime drywall substrates before the and fire resistant barrier on a wide range of building surfaces application of FireGuard E-84®. including gypsum, wood, and steel (see tech data sheet for On wood substrates where the wood is extremely old and steel). dried out, it will be necessary to scrape off any old flaking off paint (if painted) and prime the surface before the Listed and certified by Guardian Fire Test Laboratories Inc. application of FireGuard E-84®. Features -ASTM E-119 ASTM E-84 Tested -Decorative Finish- Gives a smooth decorative finish. Performance Data -Can be top-coated to color choice. -Can be brushed on, rolled on, or sprayed on Standards Tested To Results -Durable finish- Provides a hard, impact and abrasion ASTM 2768 / ASTM E-84 30 min Extended Flame Spread- 0 Smoke Index- 5 resistant surface ASTM E-84 -Topcoat finishes smooth -Thin film coating- space saving footprints ASTM E-119 1 & 2 Hour on gypsum and wood -Low VOC content UL 263 wall and floor/ceiling assemblies -LEED compliant NFPA 251 ULC-S-101 Color White Finish Smooth Primers Can be used as a finished coat or a primer.
    [Show full text]
  • Installation of Common Insulation Types: Technote Wood-Frame Walls and Attics
    TechNote Installation of Common Insulation Types: Wood-Frame Walls and Attics Thermal insulation is added to walls, roof/ceilings, and floors to slow down the flow of heat into or out of a home. For alltyp es of insulation, the quality of installation is a significant factor in creating an energy-efficient and durable building enclosure and comfortablendoor i environment. This TechNote provides practical information for the installation of three types of insulation in various applications. Itis intended to help builders and designers meet the requirements of the energy code and maximize the value of each insulation type. Insulation Types Addressed material into wall cavities or onto an spray-applied into open wall cavities. attic floor. In open-frame wall cavities, Damp blown cellulose requires time to Fiberglass is composed of spun glass the fiberglass is held in place by a dry before drywall can be installed. fibers. netting material or can be coated with Spray Polyurethane Foam (SPF) is an acrylic binder during application. Fiberglass Batts have glass fibers fabricated on site using two components coated with a bonding agent. The batts Cellulose insulation is made up of sprayed through a nozzle. Proper foam come in pre-cut lengths and fit between 70% - 85% recycled newspaper, formation requires adhering to standard wall stud spacing or are and is shredded and treated for fire, pest, manufacturer instructions on ambient shipped in rolls and cut to length at the and mold resistance. temperature and humidity, as well as job site. Batts are hand-cut/trimmed to receiving substrate temperature. The be installed around pipes, electrical Dry-Blown Cellulose is installed using SPF cures in place and a short period of wiring, and in non-standard cavities.
    [Show full text]
  • Fire Retardant Paint Latex Intumescent Coating Flat Finish Fr-110
    FIRE RETARDANT PAINT LATEX INTUMESCENT COATING FLAT FINISH FR-110 Features General Description • Intumescent product • Applies like a regular Insl-x® Fire Retardant Paint is a high-quality latex decorative, • Flame Spread Rating: paint intumescent, fire retardant coating for interior ceilings, walls and Class "A" when tested in • Soap and water trim. This product provides a high-hiding flat finish that retards accordance with ASTM E-84 cleanup flame spread by reacting to heat and forming a thick cellular char blanket (intumescence). By reducing excessive heat (NFPA 255) and S-102. • Low VOC penetration, this product retards flame spread and minimizes smoke generation. It is suitable for primed or previously painted wood, drywall, cellulose tile, cured plaster, masonry and metal. It applies like a conventional latex paint, low in VOCs, and washes without spotting. Recommended For Limitations For interior use on primed or previously painted wood, drywall, • Use product when surface temperature is between 50 °F cellulose tile, cured plaster, masonry and metal. NOTE: Top (10 °C) and 95 °F (35 °C). coating this product will reduce its intumescent properties. Product Information Colors — Standard: Technical Data◊ White White FR-110 Vehicle Type Vinyl Acrylic Can be tinted with up to 2 oz. of Universal Colorants. Pigment Type Titanium Dioxide — Tint Bases: Volume Solids 46.0 ± 1.0% NA Coverage per Gallon and per coat at Recommended Film Thickness — Special Colors: Note: 10 minute burn class A rating. ASTM-E-84 with Contact your dealer. spread rate: 2 coats at 300-330 square feet/gallon (4.7- 5.2 mils WFT and 2.2-2.4 mils DFT each) Certifications & Qualifications: Note: 30 minute burn class A rating.
    [Show full text]
  • Proform® Brand Sta-Smooth® Hs Joint Compound
    09250 PROFORM® BRAND STA-SMOOTH® HS JOINT COMPOUND MANUFACTURER • Available in four popular • High-speed mixing or exces- and evenly, and is immedi- º. working-set times to meet sive mixing will shorten the ately ready to receive the National Gypsum Company industry needs: 20, 30, 45 working life of the Sta-Smooth joint compound. Sta-Smooth 2001 Rexford Road and 60 minutes. HS Compound. HS tape is 2" wide and Charlotte, NC 28211 • Packaged in easy-to-carry • Do not add water or remix available in 300' rolls, 12 rolls (704) 365-7300 25-lb. bags. after compound begins to per case. Technical Information: • When a spray texture is spec- thicken and harden. ProForm Joint Tape. This paper 1-800-NATIONAL ified for ceilings, the usual • Storage life in high humidity reinforcing tape conceals and (1-800-628-4662) second coat of compound area is 6 months; other areas reinforces wallboard joints. Buffered edges on both sides Fax: 1-800-FAX NGC1 can be eliminated. This saves up to 12 months maximum. ensure optimum working (1-800-329-6421) valuable time and labor in assembly line operations. COMPOSITION & MATERIALS qualities and bond. Center- Internet Home Page: Contains no asbestos. May creasing process allows easy www.nationalgypsum.com • Noncombustible. contain any of the following: folding for corners. Tape is 2 1/16" wide and is available 09250/NGC Buyline: 1100 LIMITATIONS Component CAS No. in 250' rolls (20 per carton) • Bags should be kept closed Quartz 14808-06-7 or 500' rolls (10 per carton). º. DESCRIPTION and as airtight as possible.
    [Show full text]
  • Fire Resistance Provided by Gypsum Board Membrane Protection (Ga-610-02)
    FIRE RESISTANCE PROVIDED BY GYPSUM BOARD MEMBRANE PROTECTION (GA-610-02) Introduction must be approved by the authority having Dividing buildings into distinct fire-protected jurisdiction. areas is typically accomplished by providing fire- When to Use a Membrane Rating resistance rated separations between those areas. This Fire tests on floor-ceiling systems are historically type of separation is easily achieved by the use of conducted with fully loaded solid-sawn nominal 2x10 gypsum board applied to either wood or steel framing (38x235 mm) floor framing. Hundreds of fire tests members. These fire-rated separations are usually were conducted prior to the development of provided as total assemblies, consisting of the engineered wood trusses, wood I-joists, and structural member, the gypsum board and structural lightweight steel joists. In certain types of new flooring material (if a floor/ceiling assembly). Listings construction, it may be neither practical nor of many fire-rated assemblies or Designs are found in economical to use the type of structural components the GA-600, UL Fire Resistance Directory, etc. found in tested and listed systems. In addition, However, often no fire-rated assembly exists to engineered systems taking into account the actual match a particular configuration to be built. This is loads and spans enable designers to specify systems often the case for retrofit work, but may also occur in that may not require 2x10 (38x235 mm) joists. These new construction. In this case all of the fire resistance engineered systems often specify smaller dimension may be provided by a gypsum board “membrane”; lumber, wood trusses, wood I-joists, other engineered typically several layers of fire-rated (type X) gypsum lumber products, steel channel joists, or other board.
    [Show full text]
  • Passive Firestop Systems Critical for Building Occupants
    10/23/13 4:29 PM Passive firestop systems critical for building occupants By Gregg Stahl Instruments of active fire protection, such as sprinkler systems and fire extinguishers, are a common sight in most buildings – they are always located where building occupants can easily see and access them, if needed. Not as much attention is given to passive fire protection systems, embedded into interior building assemblies, away from public view. However, they are just as integral to the protection of the structure and its occupants in the event of a fire. A key component of commercial building design, passive fire protection's aim is to contain a fire at its source and prevent the spread of flames and smoke throughout a building to allow occupants more time to safely evacuate the structure. The most important area of concentration for these passive fire protection design strategies is the wall assembly, and the most effective mode of passive fire protection is the passive firestop system. Passive firestop systems Fire and smoke can travel through gaps in wall assemblies. Therefore, it is necessary to seal off any wall perimeter joints or penetrations for switches, electrical boxes, power outlets or the passage of pipes, cables or HVAC ductwork with firestop materials. Typically, these materials include: sealants, intumescent materials, sprays, mechanical devices and foam blocks or pillows. It is important to remember that there isn't one universal product that will work for every firestop application. It is also important to select products that have been tested appropriately to meet applicable fire safety standards. The two materials most commonly used in passive firestop systems for today's commercial building projects are sealants and intumescent materials.
    [Show full text]
  • Improved Lightweight Joint Compound
    Europaisches Patent a mt J» European Patent Office GO Publication number: 0 211 522 Office europeen des brevets A1 EUROPEAN PATENT APPLICATION © Application number: 86305159.5 © intci/1: C 04 B 14/18 C 04 B 20/10, C 04 B 28/02 © Dateoffiling: 03.07.86 (*>) Priority: 05.07.85 US 752268 \T}) Applicant: USG Corporation 101 South Wacker Drive Chicago Illinois 60606(US) © Date of publication of application : 25.02.87 Bulletin 87/9 © Inventor: Struss, Arthur William 736 Fairiawn Avenue @ Designated Contracting States: Ubertyville Illinois 60048(US) AT BE CH DE FR IT LI LU NL SE S) Representative: Seaborn, George Stephen et al. c/o Edward Evans & Co. Chancery House 53-64 Chancery Lane London WC2A1SD(GB) @ Improved lightweight joint compound. © Expanded perlite coated with an amino-functional sil- oxane and a silicone wetting agent, and a joint compound incorporating same, which, when applied to gypsum wall- board, has improved bonding properties and greater uni- formity in paint gloss appearance between the surface of the joint compound and the surface of the wallboard. (M CM 10 CM O Q. 11! Croydon Priming Company Ltd 0211522 - i - IMPROVED LIGHTWEIGHT JOINT COMPOUND BACKGROUND OF THE INVENTION Field of the Invention The present invention relates to a joint compound for use in filling and coating the joints between adjacent gypsum wallboards, and more par- ticularly refers to a joint compound of the type described which is light weight, is readily sandable, has lower shrinkage, provides a reduction in transportation costs because of its lightweight, and provides additional improved properties such as better adhesion and improved paintability than prior art lightweight joint compounds.
    [Show full text]
  • UL XHEZ.W-L-3231 Drywall 1 and 2 Hr. Through-Penetration Firestop System Using Unique Fire Stop Products – Smooth Penetrator
    UL XHEZ.W-L-3231 Drywall 1 and 2 Hr. Through-penetration Firestop System using Unique Fire Stop Products – Smooth Penetrator 1. Wall Assembly — The 1 or 2 hr fire-rated gypsum board/stud wall assembly shall be constructed of the materials and in the manner described in the individual U300, U400 or V400 Series Wall and Partition Designs in the UL Fire Resistance Directory and shall include the following construction features: A. Studs — Wall framing shall consist of either wood studs or steel channel studs. Wood studs to consist of nom 2 by 4 in. (51 by 102 mm) lumber spaced 16 in. (406 mm) OC. Steel studs to be min 3-5/8 in. (92 mm) wide and spaced 24 in. (610 mm) OC. B. Gypsum Board* — 5/8 in. (16 mm) thick, 4 ft (1219 mm) wide with square or tapered edges. The gypsum board type, thickness, number of layers, fastener type and sheet orientation shall be as specified in the individual U300, U400 or V400 Series Designs in the UL Fire Resistance Directory. The hourly F Rating of the firestop system is equal to the hourly fire rating of the wall assembly in which it is installed. 2. Cables — Aggregate cross-sectional area of cables in Smooth Sleeve to be min 8 percent to max 48 percent of the aggregate cross- sectional area of the Smooth Sleeve. Cables to be rigidly supported on both sides of wall assembly. Any combination of the following types and sizes of cables may be used: 251-960-5018 Unique Fire Stop Products, Inc.
    [Show full text]