TEST REPORT IEC 60598-2-2 Luminaires Part 2: Particular requirements: Section Two – Recessed luminaires

Report Number...... : 64.140.13.03702.02 Date of issue...... : 2015-03-11 Total number of pages ...... 36 Testing Laboratory ...... : TÜV SÜD Certification and Testing () Co., Ltd. GuangZhou Branch Address ...... : 5F, Communication Building, 163 Pingyun Rd, Huangpu Ave. West Guangzhou 510656 P. R. China Applicant’s name ...... : Opple Lighting Co., Ltd. Address ...... : Building 3, 1999 Lane, Zhang Heng Road, Zhang Jiang Pudong District, , China. Test specification: Standard ...... : IEC 60598-2-2 (Third Edition): 2011 used in conjunction with IEC 60598-1 (Seventh Edition): 2008 Test procedure ...... : CE_LVD Non-standard test method…………..: N/A Test Report Form No...... : IEC60598_2_2B Test Report Form(s) Originator ...... : Intertek Semko AB Master TRF ...... : 2012-02 Copyright © 2012 IEC System for Conformity Testing and Certification of Electrical Equipment (IECEE), Geneva, Switzerland. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. If this Test Report Form is used by non-IECEE members, the IECEE/IEC logo and the reference to the CB Scheme procedure shall be removed. Test item description ...... : LED down light Trade Mark ...... : OPPLE Manufacturer ...... : Opple Lighting Co., Ltd. Address ...... : East Side, Fenyang Road, Fenhu Economic Development Zone, Wujiang City, Jiangsu Province, P.R.China Model/Type reference ...... : See model list Ratings ...... : 220-240V~, 50/60 Hz, other see model list Cl. II, IP20 (recessed parts), IP44 (exposed parts)

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.:00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 1 of 36 http://www.tuv-sud.cn P.R.China

List of Attachments (including a total number of pages in each attachment): EN 60598-1:2008 + A11:2009, see page 34. European Group Differences and National Differences, see page 35-36. Attachment 1: IEC 62031:2008 + A1:2012 used in conjunction with EN 62031:2008 test report, 6 pages. Attachment 2: IEC 62471:2006 + EN 62471:2008 test report, 14 pages. Attachment 3: IEC 61347-1:2007 (Second Edition) + A1:2010 + A2:2012 used in conjunction with EN 61347-1:2008+ A1:2011+ A2:2013 and Additional requirements of VC9087 test report, 43 pages. Attachment 4: IEC 62493:2009 and EN 62493:2010 test report, 1 page. Attachment 5: IEC 60598-2-6:1994+A1:1996 used in conjunction with EN 60598-2-6:1994+A1:1997 test report, 2 pages. Attachment 6: Additional requirements of VC8055 for South Africa, 3 pages.

Summary of testing: Full tests were performed on model LED DL-RC-HR R210 42W-GP, LED DL-RC-HR R175 14W-GP, LED DL-RC-HR R120 9W-GP and LED DL-RC-HR R100 6W-GP, which represents the all models, and the LED drivers OP-DY220/40-150CC, OP-DY220/13.5-150CC, OP-DY220/8-150CC and OP-DY220/7-150CC are tested together with appliance. Tests performed (name of test and test clause): Testing location: - This report was based on original report: TÜV SÜD Certification and Testing (China) Co., Ltd. 64.140.13.03702.01. This report was to change the GuangZhou Branch model name, Logo printing colour, and label. Details 5F, Communication Building, 163 Pingyun Rd, referred to copy of marking plate and model list. No Huangpu Ave. West Guangzhou 510656 P. R. China additional test was needed. - The product fulfils the requirements of IEC 60598-2- 2:2011 used in conjunction with IEC 60598-1: 2008; EN 60598-2-2:2012 used in conjunction with EN 60598-1:2008+A11:2009. - The LED driver in these products has been test according to IEC 61347-1: 2007+A1:2010+A2: 2012 used in conjunction with IEC 61347-2-13: 2006 used in conjunction with EN 61347-1:2008+ A1:2011+ A2:2013.

Summary of compliance with National Differences: European Group Differences and National Differences for Iraq, Kuwait, Malaysia, Thailand, Philippine, Brazil and South Africa are considered. List of countries addressed: All CENELEC countries

The product fulfils the requirements of IEC 60598-2-2:2011 used in conjunction with IEC 60598-1: 2008; EN 60598-2-2:2012 used in conjunction with EN 60598-1:2008+A11:2009

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.:00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 3 of 36 http://www.tuv-sud.cn P.R.China

Copy of marking plate The followed markings are only the sample. The others are same as the sample except the model name and parameter, see model list for details. Luminaire label:

Affixed on Exposed part of luminaire Affixed on recessed part of luminaire

LED driver label:

Note: According to the EU decision 768/2008/EC, the name and address of manufacturer (an EU-based importer or authorized representative if the manufacturer is not based in EU) shall be affixed on the product or, where that is not possible, on its packaging or in a document accompanying the product before the product is placed on EU market. The height of the letters is not less than 2mm, symbol of WEEE is not less than 7 mm, the height of other

symbols is not less than 5mm, “ ” is not less than 25mm for each side.

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.:00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 4 of 36 http://www.tuv-sud.cn P.R.China

Test item particulars ...... : LED down light Classification of installation and use ...... : Recessed Class II, indoor use Supply Connection ...... : Terminal block of LED driver Degree of protection ...... : IP20 (recessed parts) IP44 (exposed parts) Possible test case verdicts: - test case does not apply to the test object ...... : N/A - test object does meet the requirement ...... : P (Pass) - test object does not meet the requirement ...... : F (Fail) Testing ...... : Date of receipt of test item ...... : 2014-03-10 Date (s) of performance of tests ...... : 2014-03-10 to 2014-04-15 and 2015-03-05 to 2015- 03-11

General remarks: The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory. "(See Enclosure #)" refers to additional information appended to the report. "(See appended table)" refers to a table appended to the report. Throughout this report a comma (point) is used as the decimal separator. Clause numbers between brackets refer to clauses in IEC 60598-1 Manufacturer’s Declaration per sub-clause 6.2.5 of IECEE 02: The application for obtaining a CB Test Certificate Yes includes more than one factory location and a Not applicable declaration from the Manufacturer stating that the sample(s) submitted for evaluation is (are) representative of the products from each factory has been provided ...... :

When differences exist; they shall be identified in the General product information section. Name and address of factory (ies) ...... : 1. Suzhou OPPLE Lighting Co., Ltd. East Side, Fenyang Road, Fenhu Economic Development Zone, Wujiang City, Jiangsu Province, P.R. China. 2. Opple Lighting Electronic () Co., Ltd. Building A, No.275 Dongan Bei Road, Haizhou District, Guzhen Town, Zhongshan City, , China.

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.:00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 5 of 36 http://www.tuv-sud.cn P.R.China

General product information: LED recessed luminaries for indoors use, Non-replaceable LEDs light source, incorporated the Independent LED driver, connect to the supply via terminal block of LED driver. The all models have same construction and same LED chip use, only the size and number of LEDs different. LED DL-RC-HR R210 42W-GP and LED DL-RC-HM R210 42W-GP are same, only different in reflector, LED DL-RC-HR R210 29W-GP and LED DL-RC-HM R210 29W-GP, LED DL-RC-HR R175 14W-GP and LED DL-RC-HM R175 14W-GP, LED DL-RC-HR R120 9W-GP and LED DL-RC-HM R120 9W-GP, LED DL-RC-HR R100 6W-GP and LED DL-RC-HM R100 6W-GP, LED DL-RC-HR R82 5W-GP and LED DL- RC-HM R82 5W-GP, have same condition as LED DL-RC-HR R210 42W-GP and LED DL-RC-HM R210 42W-GP. LED DL-RC-HM R210 29W-GP, LED DL-RC-HM R175 14W-GP, LED DL-RC-HM R120 9W-GP, LED DL- RC-HM R100 6W-GP and LED DL-RC-HM R82 5W-GP use the same reflector as LED DL-RC-HM R210 42W-GP, different on dimension. This report cover the following models: Model No.: Ratings: LED driver used LED DL-RC-HR R210 42W-GP 220-240V~, 50/60Hz, max. 42W (80x 0,5W LEDs), 3000K or 4000K LED DL-RC-HM R210 42W-GP or 5700K OP-DY220/40- LED DL-RC-HR R210 29W-GP 220-240V~, 50/60Hz, 150CCC max. 29W (54x 0,5W LEDs), 3000K or 4000K LED DL-RC-HM R210 29W-GP or 5700K LED DL-RC-HR R175 14W-GP 220-240V~, 50/60Hz, OP- max. 14W (27x 0,5W LEDs), 3000K or 4000K DY220/13.5- LED DL-RC-HM R175 14W-GP or 5700K 150CC 220-240V~, 50/60Hz, LED DL-RC-HR R120 9W-GP OP-DY220/8- max. 9W (16x 0,5W LEDs), 3000K or 4000K or 150CC LED DL-RC-HM R120 9W-GP 5700K LED DL-RC-HR R100 6W-GP 220-240V~, 50/60Hz, max. 6W (11x 0,5W LEDs), 3000K or 4000K or LED DL-RC-HM R100 6W-GP 5700K OP-DY220/7- LED DL-RC-HR R82 5W-GP 220-240V~, 50/60Hz, 150CC max. 5W (8x 0,5W LEDs), 3000K or 4000K or LED DL-RC-HM R82 5W-GP 5700K Independent LED driver, Auto-wound, constant current, input and output via terminal block, class II. The all models have same construction, except the model OP-DY220/40-150CC and OP-DY220/7-150CC, the other models have same principle of circuits, PCB layout and size, only the output rating different. Model and ratings: Model Ratings Input: 220-240V~, 50/60 Hz, 0,21A OP-DY220/40-150CC Output: constant current 150mA, 150V-280Vd.c., Max. 400V Load: Max. 40W, ta: 50°C, tc: 75°C Input: 220-240V~, 50/60 Hz, 0,09A OP-DY220/13.5-150CC Output: constant current 150mA, 75V-95Vd.c., Max. 350V Load: Max. 13.5W, ta: 50°C, tc: 75°C Input: 220-240V~, 50/60 Hz, 0,07A OP-DY220/8-150CC Output: constant current 150mA, 45V-56Vd.c., Max. 350V Load: Max. 8W, ta: 50°C, tc: 75°C Input: 220-240V~, 50/60 Hz, 0,045A OP-DY220/7-150CC Output: constant current 150mA, 10V-50Vd.c., Max. 350V Load: Max. 7W, ta: 50°C, tc: 65°C

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.:00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 6 of 36 http://www.tuv-sud.cn P.R.China

IEC 60598-2-2 Clause Requirement + Test Result - Remark Verdict

2.3 (0) GENERAL TEST REQUIREMENTS P 2.3 (0.1) Information for luminaire design considered Standard ⎯ Yes No 2.3 (0.3) More sections applicable ...... :Yes No ⎯

2.5 (2) CLASSIFICATION P 2.5 (2.2) Type of protection ...... : Class II ⎯ 2.5 (2.3) Degree of protection ...... : IP20 (recessed parts) ⎯ IP44 (exposed parts) 2.5 (2.4) Luminaire suitable for direct mounting on normally Yes No ⎯ flammable surfaces ...... : Luminaire not suitable for direct mounting on Yes No ⎯ normally flammable surfaces ...... : 2.5 (2.5) Luminaire for normal use ...... : Yes No ⎯ Luminaire for rough service ...... : Yes No ⎯

2.6 (3) MARKING P 2.6 (3.2) Mandatory markings P Position of the marking P Format of symbols/text P 2.6 (3.3) Additional information P Language of instructions English was checked P 2.6 (3.3.1) Combination luminaires N/A 2.6 (3.3.2) Nominal frequency in Hz 50/60Hz P 2.6 (3.3.3) Operating temperature N/A 2.6 (3.3.4) Symbol or warning notice N/A 2.6 (3.3.5) Wiring diagram N/A 2.6 (3.3.6) Special conditions N/A 2.6 (3.3.7) Metal halide lamp luminaire – warning N/A 2.6 (3.3.8) Limitation for semi-luminaires N/A 2.6 (3.3.9) Power factor and supply current N/A 2.6 (3.3.10) Suitability for use indoors For indoor use only P 2.6 (3.3.11) Luminaires with remote control N/A 2.6 (3.3.12) Clip-mounted luminaire – warning N/A

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.:00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 7 of 36 http://www.tuv-sud.cn P.R.China

IEC 60598-2-2 Clause Requirement + Test Result - Remark Verdict

2.6 (3.3.13) Specifications of protective shields N/A 2.6 (3.3.14) Symbol for nature of supply ~ P 2.6 (3.3.15) Rated current of socket outlet N/A 2.6 (3.3.16) Rough service luminaire N/A 2.6 (3.3.17) Mounting instruction for type Y, type Z and some Type Y P type X attachments 2.6 (3.3.18) Non-ordinary luminaires with PVC cable N/A 2.6 (3.3.19) Protective conductor current in instruction if N/A applicable 2.6 (3.3.20) Provided with information if not intended to be N/A mounted within arm’s reach 2.6 (3.4) Test with water Rubbing with water for 15s P Test with hexane Rubbing with petroleum spirit P for 15s Legible after test Still legible P Label attached No curling P

2.7 (4) CONSTRUCTION P 2.7 (4.2) Components replaceable without difficulty P 2.7 (4.3) Wireways smooth and free from sharp edges P 2.7 (4.4) Lampholders N/A 2.7 (4.4.1) Integral lampholder N/A 2.7 (4.4.2) Wiring connection N/A 2.7 (4.4.3) Lampholder for end-to-end mounting N/A 2.7 (4.4.4) Positioning N/A - pressure test (N) ...... : N/A After test the lampholder comply with relevant N/A standard sheets and show no damage After test on single-capped lampholder the N/A lampholder have not moved from its position and show no permanent deformation - bending test (N) ...... : N/A After test the lampholder have not moved from its N/A position and show no permanent deformation 2.7 (4.4.5) Peak pulse voltage N/A 2.7 (4.4.6) Centre contact N/A

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.:00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 8 of 36 http://www.tuv-sud.cn P.R.China

IEC 60598-2-2 Clause Requirement + Test Result - Remark Verdict

2.7 (4.4.7) Parts in rough service luminaires resistant to N/A tracking 2.7 (4.4.8) Lamp connectors N/A 2.7 (4.4.9) Caps and bases correctly used N/A 2.7 (4.5) Starter holders N/A Starter holder in luminaires other than class II N/A Starter holder class II construction N/A 2.7 (4.6) Terminal blocks N/A Tails N/A Unsecured blocks N/A 2.7 (4.7) Terminals and supply connections P 2.7 (4.7.1) Contact to metal parts P 2.7 (4.7.2) Test 8 mm live conductor P Test 8 mm earth conductor N/A 2.7 (4.7.3) Terminals for supply conductors P 2.7 (4.7.3.1) Welded connections: N/A - stranded or solid conductor N/A - spot welding N/A - welding between wires N/A - Type Z attachment N/A - mechanical test according to 15.8.2 N/A - electrical test according to 15.9 N/A - heat test according to 15.9.2.3 and 15.9.2.4 N/A 2.7 (4.7.4) Terminals other than supply connection N/A 2.7 (4.7.5) Heat-resistant wiring/sleeves N/A 2.7 (4.7.6) Multi-pole plug N/A - test at 30 N N/A 2.7 (4.8) Switches: N/A - adequate rating N/A - adequate fixing N/A - polarized supply N/A - compliance with 61058-1 for electronic switches N/A 2.7 (4.9) Insulating lining and sleeves P 2.7 (4.9.1) Retainement P

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.:00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 9 of 36 http://www.tuv-sud.cn P.R.China

IEC 60598-2-2 Clause Requirement + Test Result - Remark Verdict

Method of fixing ...... : P 2.7 (4.9.2) Insulated linings and sleeves P Resistant to a temperature > 20 °C to the wire P temperature or a) & c) Insulation resistance and electric strength P b) Ageing test. Temperature (°C) ...... : N/A 2.7 (4.10) Insulation of Class II luminaires P 2.7 (4.10.1) No contact, mounting surface – accessible metal P parts – wiring of basic insulation Safe installation fixed luminaires P Capacitors and switches N/A Interference suppression capacitors according to N/A IEC 60384-14 2.7 (4.10.2) Assembly gaps: P - not coincidental P - no straight access with test probe N/A 2.7 (4.10.3) Retainment of insulation: P - fixed P - unable to be replaced; luminaire inoperative P - sleeves retained in position P - lining in lampholder N/A 2.7 (4.11) Electrical connections P 2.7 (4.11.1) Contact pressure P 2.7 (4.11.2) Screws: N/A - self-tapping screws N/A - thread-cutting screws N/A 2.7 (4.11.3) Screw locking: N/A - spring washer N/A - rivets N/A 2.7 (4.11.4) Material of current-carrying parts P 2.7 (4.11.5) No contact to wood or mounting surface P 2.7 (4.11.6) Electro-mechanical contact systems N/A 2.7 (4.12) Mechanical connections and glands P 2.7 (4.12.1) Screws not made of soft metal P

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.:00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 10 of 36 http://www.tuv-sud.cn P.R.China

IEC 60598-2-2 Clause Requirement + Test Result - Remark Verdict

Screws of insulating material N/A Torque test: torque (Nm); part ...... : 0,6Nm, Ф3,02mm, Screw P fixing plastic enclosure Torque test: torque (Nm); part ...... : 0,5Nm, Ф2,93mm, Screw P fixing LED module Torque test: torque (Nm); part ...... : 0,5Nm, Ф2,83mm, Screw use P on cord anchorage 2.7 (4.12.2) Screws with diameter < 3 mm screwed into metal P 2.7 (4.12.4) Locked connections: N/A - fixed arms; torque (Nm) ...... : N/A - lampholder; torque (Nm)...... : N/A - push-button switches; torque 0,8 Nm ...... : N/A 2.7 (4.12.5) Screwed glands; force (Nm) ...... : N/A 2.7 (4.13) Mechanical strength P 2.7 (4.13.1) Impact tests: P - fragile parts; energy (Nm) ...... : Plastic cover, 0,2Nm P - other parts; energy (Nm) ...... : LED module(ceramic), P Enclosure, 0,35Nm 1) live parts P 2) linings P 3) protection P 4) covers P 2.7 (4.13.3) Straight test finger 30N P 2.7 (4.13.4) Rough service luminaires N/A - IP54 or higher N/A a) fixed N/A b) hand-held N/A c) delivered with a stand N/A d) for temporary installations and suitable for N/A mounting on a stand 2.7 (4.13.6) Tumbling barrel N/A 2.7 (4.14) Suspensions and adjusting devices P 2.7 (4.14.1) Mechanical load: P A) four times the weight 1,187kg x4=4,748kg, Max. of P model LED DL-RC-HR R210 42W-GP

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.:00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 11 of 36 http://www.tuv-sud.cn P.R.China

IEC 60598-2-2 Clause Requirement + Test Result - Remark Verdict

B) torque 2,5 Nm N/A C) bracket arm; bending moment (Nm) ...... : N/A D) load track-mounted luminaires N/A E) clip-mounted luminaires, glass-shelve. N/A Thickness (mm) ...... : Metal rod. diameter (mm) ...... : N/A Fixed luminaire or independent control gear N/A without fixing devices 2.7 (4.14.2) Load to flexible cables N/A Mass (kg) ...... : N/A Stress in conductors (N/mm²) ...... : N/A Mass (kg) of semi-luminaire ...... : N/A Bending moment (Nm) of semi-luminaire ...... : N/A 2.7 (4.14.3) Adjusting devices: N/A - flexing test; number of cycles ...... : N/A - strands broken N/A - electric strength test afterwards N/A 2.7 (4.14.4) Telescopic tubes: cords not fixed to tube; no N/A strain on conductors 2.7 (4.14.5) Guide pulleys N/A 2.7 (4.14.6) Strain on socket-outlets N/A 2.7 (4.15) Flammable materials: P - glow-wire test 650 °C P - spacing ≥ 30 mm N/A - screen withstanding test of 13.3.1 N/A - screen dimensions N/A - no fiercely burning material P - thermal protection N/A - electronic circuits exempted N/A 2.7 (4.15.2) Luminaires made of thermoplastic material with lamp control gear N/A a) construction N/A b) temperature sensing control N/A c) surface temperature N/A 2.7 (4.16) Luminaires for mounting on normally flammable surfaces P

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.:00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 12 of 36 http://www.tuv-sud.cn P.R.China

IEC 60598-2-2 Clause Requirement + Test Result - Remark Verdict

No lamp control gear (compliance with Section 12) N/A 2.7 (4.16.1) Lamp control gear spacing: N/A - spacing 35 mm N/A - spacing 10 mm N/A 2.7 (4.16.2) Thermal protection: N/A - in lamp control gear N/A - external N/A - fixed position N/A - temperature marked lamp control gear N/A 2.7 (4.16.3) Design to satisfy the test of 12.6 (see 12.6) P 2.7 (4.17) Drain holes N/A Clearance at least 5 mm N/A 2.7 (4.18) Resistance to corrosion: N/A 2.7 (4.18.1) - rust-resistance N/A 2.7 (4.18.2) - season cracking in copper N/A 2.7 (4.18.3) - corrosion of aluminium N/A 2.7 (4.19) Ignitors compatible with ballast N/A 2.7 (4.20) Rough service vibration N/A 2.7 (4.21) Protective shield: N/A 2.7 (4.21.1) Shield fitted N/A Shield of glass if tungsten halogen lamps N/A 2.7 (4.21.2) Particles from a shattering lamp not impair safety N/A 2.7 (4.21.3) No direct path N/A 2.7 (4.21.4) Impact test on shield N/A Glow-wire test on lamp compartment N/A 2.7 (4.22) Attachments to lamps N/A 2.7 (4.23) Semi-luminaires comply Class II N/A 2.7 (4.24) UV radiation for tungsten halogen lamps and N/A metal halide lamps (Annex P) 2.7 (4.25) No sharp point or edges P 2.7 (4.26) Short-circuit protection: N/A 2.7 (4.26.1) Uninsulated accessible SELV parts N/A 2.7 (4.26.2) Short-circuit test N/A 2.7 (4.26.3) Test chain according to Figure 29 N/A

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.:00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 13 of 36 http://www.tuv-sud.cn P.R.China

IEC 60598-2-2 Clause Requirement + Test Result - Remark Verdict

2.8 (11) CREEPAGE DISTANCES AND CLEARANCES P Working voltage (V) ...... : 220-240V~ ⎯ Voltage form Sinusoidal ⎯ Non-sinusoidal PTI < 600 > 600 ⎯ Impulse withstand category (Normal category II) Category II Category III ⎯ (Category III Annex U) Rated pulse voltage (kV) ...... : ⎯ (1) Current-carrying parts of different polarity: cr Cr/cl: 3,6 mm / 2,2 mm P (mm); cl (mm) ...... : Limit Cr/Cl: 3,5 mm / 2,1 mm (2) Current-carrying parts and accessible parts: cr Cr/cl: 5,87 mm / 5,87 mm P (mm); cl (mm) ...... : Limit Cr/Cl: 5,4 mm / 4,1 mm (3) Parts becoming live due to breakdown of N/A basic insulation and metal parts: cr (mm); cl (mm) ...... : (4) Outer surface of cable where it is clamped and N/A metal parts: cr (mm); cl (mm)...... : (6) Current-carrying parts and supporting surface: Cr/cl: 5,87 mm / 5,87 mm P cr (mm); cl (mm) ...... : Limit Cr/Cl: 5,4 mm / 4,1 mm

2.9 (7) PROVISION FOR EARTHING N/A 2.9 (7.2.1 Accessible metal parts N/A + 7.2.3) Metal parts in contact with supporting surface N/A Resistance < 0,5 Ω ...... : N/A Self-tapping screws used N/A Thread-forming screws N/A Thread-forming screw used in a grove N/A Earth makes contact first N/A 2.9 (7.2.2 Earth continuity in joints etc. N/A + 7.2.3) 2.9 (7.2.4) Locking of clamping means N/A Compliance with 4.7.3 N/A Terminal blocks with integrated screwless N/A earthing contacts tested according Annex V 2.9 (7.2.5) Earth terminal integral part of connector socket N/A

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.:00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 14 of 36 http://www.tuv-sud.cn P.R.China

IEC 60598-2-2 Clause Requirement + Test Result - Remark Verdict

2.9 (7.2.6) Earth terminal adjacent to mains terminals N/A 2.9 (7.2.7) Electrolytic corrosion of the earth terminal N/A 2.9 (7.2.8) Material of earth terminal N/A Contact surface bare metal N/A 2.9 (7.2.10) Class II luminaire for looping-in N/A Double or reinforced insulation to functional earth N/A 2.9 (7.2.11) Earthing core coloured green-yellow N/A Length of earth conductor N/A 2.9.1 (-) Attachment prevented from rotation N/A

2.10 (14) SCREW TERMINALS P Separately approved; component list (see Annex 1) P Part of the luminaire (see Annex 3) N/A

2.10 (15) SCREWLESS TERMINALS AND ELECTRICAL CONNECTIONS N/A Separately approved; component list (see Annex 1) N/A Part of the luminaire (see Annex 4) N/A

2.11 (5) EXTERNAL AND INTERNAL WIRING P 2.11 (5.2) Supply connection and external wiring P 2.11 (5.2.1) Means of connection ...... : Terminal block of LED driver P 2.11 (5.2.2) Type of cable ...... : H03VVH2-F P Nominal cross-sectional area (mm²) ...... : 2x 0,75 mm² P Cables equal to IEC 60227 or IEC 60245 IEC 60227 P 2.11 (5.2.3) Type of attachment, X, Y or Z Y P 2.11 (5.2.5) Type Z not connected to screws N/A 2.11 (5.2.6) Cable entries: P - suitable for introduction P - adequate degree of protection P 2.11 (5.2.7) Cable entries through rigid material have rounded P edges 2.11 (5.2.8) Insulating bushings: P - suitably fixed P - material in bushings P

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.:00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 15 of 36 http://www.tuv-sud.cn P.R.China

IEC 60598-2-2 Clause Requirement + Test Result - Remark Verdict

- material not likely to deteriorate P - tubes or guards made of insulating material P 2.11 (5.2.9) Locking of screwed bushings N/A 2.11 (5.2.10) Cord anchorage: P - covering protected from abrasion P - clear how to be effective P - no mechanical or thermal stress P - no tying of cables into knots etc. P - insulating material or lining P 2.11 Cord anchorage for type X attachment: N/A (5.2.10.1) a) at least one part fixed N/A b) types of cable N/A c) no damaging of the cable N/A d) whole cable can be mounted N/A e) no touching of clamping screws N/A f) metal screw not directly on cable N/A g) replacement without special tool N/A Glands not used as anchorage N/A Labyrinth type anchorages N/A 2.11 Adequate cord anchorage for type Y and type Z P (5.2.10.2) attachment 2.11 Tests: P (5.2.10.3) - impossible to push cable; unsafe P - pull test: 25 times; pull (N) ...... : 60N P - torque test: torque (Nm) ...... : 0,15Nm P - displacement ≤ 2 mm 0,15mm P - no movement of conductors P - no damage of cable or cord P 2.11 (5.2.11) External wiring passing into luminaire P 2.11 (5.2.12) Looping-in terminals N/A 2.11 (5.2.13) Wire ends not tinned N/A Wire ends tinned: no cold flow N/A 2.11 (5.2.14) Mains plug same protection N/A

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.:00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 16 of 36 http://www.tuv-sud.cn P.R.China

IEC 60598-2-2 Clause Requirement + Test Result - Remark Verdict

Class III luminaire plug N/A 2.11 (5.2.16) Appliance inlets (IEC 60320) N/A Appliance couplers of class II type N/A 2.11 (5.2.17) No standardized interconnecting cables properly N/A assembled 2.11 (5.2.18) Used plug in accordance with N/A - IEC 60083 N/A - other standard N/A 2.11 (5.3) Internal wiring N 2.11 (5.3.1) Internal wiring of suitable size and type P Through wiring N/A - not delivered/ mounting instruction N/A - factory assembled N/A - socket outlet loaded (A) ...... : N/A - temperatures ...... : (see Annex 2) N/A Green-yellow for earth only N/A 2.11 (5.3.1.1) Internal wiring connected directly to fixed wiring N/A Cross-sectional area (mm²) ...... : N/A Insulation thickness N/A Extra insulation added where necessary N/A 2.11 (5.3.1.2) Internal wiring connected to fixed wiring via internal current-limiting device N/A Adequate cross-sectional area and insulation N/A thickness 2.11 (5.3.1.3) Double or reinforced insulation for class II P 2.11 (5.3.1.4) Conductors without insulation N/A 2.11 (5.3.1.5) SELV current-carrying parts N/A 2.11 (5.3.1.6) Insulation thickness other than PVC or rubber N/A 2.11 (5.3.2) Sharp edges etc. P No moving parts of switches etc. N/A Joints, raising/lowering devices N/A Telescopic tubes etc. N/A No twisting over 360° P 2.11 (5.3.3) Insulating bushings: P - suitable fixed P

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.:00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 17 of 36 http://www.tuv-sud.cn P.R.China

IEC 60598-2-2 Clause Requirement + Test Result - Remark Verdict

- material in bushings P - material not likely to deteriorate P - cables with protective sheath P 2.11 (5.3.4) Joints and junctions effectively insulated N/A 2.11 (5.3.5) Strain on internal wiring N/A 2.11 (5.3.6) Wire carriers N/A 2.11 (5.3.7) Wire ends not tinned N/A Wire ends tinned: no cold flow P

2.12 (8) PROTECTION AGAINST ELECTRIC SHOCK P 2.12 (8.2.1) Live parts not accessible P Basic insulated parts not used on the outer P surface without appropriate protection Basic insulated parts not accessible with standard N/A test finger on portable and adjustable luminaires Basic insulated parts not accessible with Ø 50 N/A mm probe from outside, within arm’s reach, on wall-mounted luminaires Lamp and starterholders in portable and N/A adjustable luminaires comply with double or reinforced insulation requirements Basic insulation only accessible under lamp or N/A starter replacement Protection in any position P Double-ended tungsten filament lamp N/A Insulation lacquer not reliable P Double-ended high pressure discharge lamp N/A Relevant warning according to 3.2.18 fitted to the N/A luminaire 2.12 (8.2.2) Portable luminaire adjusted in most unfavourable N/A position 2.12 (8.2.3.a) Class II luminaire: P - basic insulated metal parts not accessible during N/A starter or lamp replacement - basic insulation not accessible other than during N/A starter or lamp replacement - glass protective shields not used as N/A supplementary insulation

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.:00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 18 of 36 http://www.tuv-sud.cn P.R.China

IEC 60598-2-2 Clause Requirement + Test Result - Remark Verdict

2.12 (8.2.3.b) BC lampholder of metal in class I luminaires shall N/A be earthed 2.12 (8.2.3.c) Class III luminaires with exposed SELV parts: N/A Ordinary luminaire: N/A - touch current ...... : N/A - no-load voltage ...... : N/A Other than ordinary luminaire: N/A - nominal voltage ...... : N/A 2.12 (8.2.4) Portable luminaire: N/A - protection independent of supporting surface N/A 2.12 (8.2.5) Compliance with the standard test finger or P relevant probe 2.12 (8.2.6) Covers reliably secured P 2.12 (8.2.7) Discharging of capacitors ≥ 0,5 μF P Portable plug connected luminaire with capacitor N/A Other plug connected luminaire with capacitor N/A Discharge device on or within capacitor N/A Discharge device mounted separately N/A

2.13 (12) ENDURANCE TEST AND THERMAL TEST P 2.13 (12.3) Endurance test: P - mounting-position ...... : Norma use ⎯ - test temperature (°C) ...... : Ta 45+10=55 ⎯ - total duration (h) ...... : 240 ⎯ - supply voltage: Un factor; calculated voltage (V) : 240V x1,1=264V ⎯ - lamp used ...... : Non-replaceable LEDs ⎯ 2.13 (12.3.2) After endurance test: P - no part unserviceable P - luminaire not unsafe P - no damage to track system N/A - marking legible P - no cracks, deformation etc. P 2.13 (12.4) Thermal test (normal operation) (see Annex 2) P 2.13 (12.5) Thermal test (abnormal operation) (see Annex 2) P

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.:00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 19 of 36 http://www.tuv-sud.cn P.R.China

IEC 60598-2-2 Clause Requirement + Test Result - Remark Verdict

2.13 (12.6) Thermal test (failed lamp control gear condition): N/A 2.13 (12.6.1) Through wiring or looping-in wiring loaded by a ⎯ current of (A) ...... : - case of abnormal conditions ...... : ⎯ - electronic lamp control gear P - measured winding temperature (°C): at 1,1 Un . : ⎯ - measured mounting surface temperature (°C) at N/A 1,1 Un ...... : - calculated mounting surface temperature (°C) .. : N/A - track-mounted luminaires N/A 2.13 (12.6.2) Temperature sensing control N/A - case of abnormal conditions ...... : ⎯ - thermal link N/A - manual reset cut-out N/A - auto reset cut-out N/A - measured mounting surface temperature (°C) ... : N/A - track-mounted luminaires N/A 2.13 (12.7) Thermal test (failed lamp control gear in plastic luminaires): N/A 2.13 (12.7.1) Luminaire without temperature sensing control N/A 2.13 Luminaire with fluorescent lamp ≤ 70W N/A (12.7.1.1) Test method 12.7.1.1 or Annex W ...... : ⎯ Test according to 12.7.1.1: N/A - case of abnormal conditions ⎯ - Ballast failure at supply voltage (V) ...... : ⎯ - Components retained in place after the test N/A - Test with standard test finger after the test N/A Test according to Annex V: N/A - case of abnormal conditions ⎯ - measured winding temperature (°C): at 1,1 Un .. : ⎯ - measured temperature of fixing point/exposed ⎯ part (°C): at 1,1 Un ...... : - calculated temperature of fixing point/exposed ⎯ part (°C) ...... : Ball-pressure test: N/A

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.:00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 20 of 36 http://www.tuv-sud.cn P.R.China

IEC 60598-2-2 Clause Requirement + Test Result - Remark Verdict

- part tested; temperature (°C) ...... : N/A - part tested; temperature (°C) ...... : N/A 2.13 Luminaire with discharge lamp, fluorescent lamp > 70W, transformer > 10 VA N/A (12.7.1.2) - case of abnormal conditions ⎯ - measured winding temperature (°C): at 1,1 Un .. : ⎯ - measured temperature of fixing point/exposed ⎯ part (°C): at 1,1 Un ...... : - calculated temperature of fixing point/exposed ⎯ part (°C) ...... : Ball-pressure test: N/A - part tested; temperature (°C) ...... : N/A - part tested; temperature (°C) ...... : N/A 2.13 Luminaire with short circuit proof transformers N/A (12.7.1.3) ≤ 10 VA - case of abnormal conditions ⎯ - Components retained in place after the test N/A - Test with standard test finger after the test N/A 2.13 (12.7.2) Luminaire with temperature sensing control N/A - thermal link Yes No ⎯ - manual reset cut-out Yes No ⎯ - auto reset cut-out Yes No ⎯ - case of abnormal conditions ⎯ - highest measured temperature of fixing ⎯ point/exposed part (°C): ...... : Ball-pressure test: N/A - part tested; temperature (°C) ...... : N/A - part tested; temperature (°C) ...... : N/A 2.13.1 (-) Wiring, for connection to the supply, not reach unsafe temperature N/A - measured temperature of the cable (°C) ...... : N/A

2.14 (9) RESISTANCE TO DUST, SOLID OBJECTS AND MOISTURE P 2.14 (9.2) Tests for ingress of dust, solid objects and moisture: P - classification according to IP ...... : IP20 (recessed parts) ⎯ IP44 (exposed parts)

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.:00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 21 of 36 http://www.tuv-sud.cn P.R.China

IEC 60598-2-2 Clause Requirement + Test Result - Remark Verdict

- mounting position during test ...... : As per standard ⎯ - fixing screws tightened; torque (Nm) ...... : ⎯ - tests according to clauses ...... : 9.2.0; 9.21; 9.2.5; 9.2.7 ⎯ - electric strength test afterwards P a) no deposit in dust-proof luminaire N/A b) no talcum in dust-tight luminaire N/A c) no trace of water on current-carrying parts or P SELV parts or where it could become a hazard d) i) For luminaires without drain holes – no water P entry d) ii) For luminaires with drain holes – no P hazardous water entry e) no water in watertight luminaire N/A f) no contact with live parts (IP 2X) Recessed parts P f) no entry into enclosure (IP 3X and IP 4X) P f) no contact with live parts (IP3X and IP4X) P g) no trace of water on part of lamp requiring P protection from splashing water h) no damage of protective shield or glass P envelope 2.14 (9.3) Humidity test 48 h 25ºC, 93%RH P 2.14 (-) Tests order for luminaires with > IP 20 ⎯

2.15 (10) INSULATION RESISTANCE AND ELECTRIC STRENGTH P 2.15 (10.2.1) Insulation resistance test P Cable or cord covered by metal foil or replaced by ⎯ a metal rod of mm Ø ...... : Insulation resistance (MΩ) ⎯ SELV: N/A - between current-carrying parts of different N/A polarity ...... : - between current-carrying parts and mounting N/A surface ...... : - between current-carrying parts and metal parts N/A of the luminaire ...... :

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.:00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 22 of 36 http://www.tuv-sud.cn P.R.China

IEC 60598-2-2 Clause Requirement + Test Result - Remark Verdict

- between the outer surface of a flexible cord or N/A cable where it is clamped in a cord anchorage and accessible metal parts ...... : - Insulation bushings as described in Section 5 .. : N/A Other than SELV: P - between live parts of different polarity ...... : > 10 MΩ P - between live parts and mounting surface ...... : > 10 MΩ P - between live parts and metal parts ...... : > 10 MΩ P - between live parts of different polarity through N/A action of a switch ...... : - between the outer surface of a flexible cord or > 10 MΩ P cable where it is clamped in a cord anchorage and accessible metal parts ...... : - Insulation bushings as described in Section 5 .. : N/A 2.15 (10.2.2) Electric strength test P Dummy lamp N/A Luminaires with ignitors after 24 h test N/A Luminaires with manual ignitors N/A Test voltage (V): N/A SELV: N/A - between current-carrying parts of different N/A polarity ...... : - between current-carrying parts and mounting N/A surface ...... : - between current-carrying parts and metal parts N/A of the luminaire ...... : - between the outer surface of a flexible cord or N/A cable where it is clamped in a cord anchorage and accessible metal parts ...... : - Insulation bushings as described in Section 5 .. : N/A Other than SELV: P - between live parts of different polarity ...... : 1480 V P - between live parts and mounting surface ...... : 2960 V P - between live parts and metal parts ...... : 2960 V P - between live parts of different polarity through action of a switch ...... :

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.:00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 23 of 36 http://www.tuv-sud.cn P.R.China

IEC 60598-2-2 Clause Requirement + Test Result - Remark Verdict

- between the outer surface of a flexible cord or 2960 V P cable where it is clamped in a cord anchorage and accessible metal parts ...... : - Insulation bushings as described in Section 5 .. : N/A 2.15 (10.3) Touch current or protective conductor current 0,01mA, (Limit: 0,7mA) P (mA) ...... :

2.16 (13) RESISTANCE TO HEAT, FIRE AND TRACKING P 2.16 (13.2.1) Ball-pressure test: P - part tested; temperature (°C) ...... : Plastic cover, 75°C, Ф1,15mm P - part tested; temperature (°C) ...... : Plastic loop, 75°C, Ф0,9mm P 2.16 (13.3.1) Needle flame test (10 s): N/A - part tested ...... : N/A - part tested ...... : N/A 2.16 (13.3.2) Glow-wire test (650°C): P - part tested ...... : Plastic cover P - part tested ...... : Plastic loop P 2.16 (13.4.1) Tracking test: N/A - part tested ...... : N/A - part tested ...... : N/A

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.:00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 24 of 36 http://www.tuv-sud.cn P.R.China

IEC 60598-2-2 Clause Requirement + Test Result - Remark Verdict

ANNEX 1: components (CDF) P

ANNEX 2: temperature measurements, thermal tests of Section 12 P

Type reference ...... : LED DL-RC-HR R210 42W-GP ⎯ Lamp used ...... : LED (80x 0,5W) ⎯ Lamp control gear used ...... : OP-DY220/40-150CC ⎯ Mounting position of luminaire ...... : Fixing on the test recess ⎯ Supply wattage (W) ...... : Test 2: 39,3W; ⎯ test 4a: 39,2W; test 4b: 0,01W Supply current (A) ...... : Test 2: 0,16A; ⎯ test 4a: 0,16A; test 4b: 0,02A Calculated power factor ...... : 0,980 ⎯ Table: measured temperatures corrected for ta = 45 °C: P - abnormal operating mode ...... : Test 4a: S/C one LED; ⎯ Test 4b: S/C output of LED driver - test 1: rated voltage ...... : --- ⎯ - test 2: 1,06 times rated voltage or 1,05 times 240V x1,06=254,4V ⎯ rated wattage ...... : - test 3: Load on wiring to socket-outlet, ⎯ 1,06 times voltage or 1,05 times wattage ...... : - test 4: 1,1 times rated voltage or 1,05 times 240V x1,1=264V ⎯ rated wattage ...... : Through wiring or looping-in wiring loaded by a ⎯ current of A during the test ...... :

temperature (°C) of part Clause 12.4 – normal Clause 12.5 – abnormal test 1 test 2 test 3 limit test 4a Test 4b limit Input wire of LED power ⎯ 69,2 ⎯ 90 ⎯ ⎯ ⎯ supply Output wire of LED power ⎯ 70,2 ⎯ 90 ⎯ ⎯ ⎯ supply tc of LED power supply ⎯ 72,9 ⎯ 75 73,1 50,2 75+10 The max. temperature point ⎯ 66,9 ⎯ 75 ⎯ ⎯ ⎯ of LED power supply top surface

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.:00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 25 of 36 http://www.tuv-sud.cn P.R.China

IEC 60598-2-2 Clause Requirement + Test Result - Remark Verdict

Mounting surface under the ⎯ 87,7 ⎯ 90 87,9 53,0 130 LED power supply Supply wire to LED module ⎯ 82,3 ⎯ 90 ⎯ ⎯ ⎯ Cord anchorage ⎯ 75,8 ⎯ Ref. ⎯ ⎯ ⎯ Heat-shrinkable tubing ⎯ 62,9 ⎯ 125 ⎯ ⎯ ⎯ LED module ⎯ 111,8 ⎯ Ref. 119,5 46,4 Ref. Contact point between ⎯ 56,7 ⎯ 90 57,7 46,3 130 ceiling and luminaire Test recess on top of ⎯ 57,0 ⎯ 90 59,8 47,7 130 luminaire Surface of plastic cover ⎯ 84,3 ⎯ 90 ⎯ ⎯ ⎯ Lighted surface (10 cm) ⎯ 49,3 ⎯ 90 49,3 47,3 175

Type reference ...... : LED DL-RC-HR R175 14W-GP ⎯ Lamp used ...... : LED (27x 0,5W) ⎯ Lamp control gear used ...... : OP-DY220/13.5-150CC ⎯ Mounting position of luminaire ...... : Fixing on the test recess ⎯ Supply wattage (W) ...... : Test 2: 14,1W; ⎯ test 4a: 14,0W; test 4b: 0,01W Supply current (A) ...... : Test 2: 0,07A; ⎯ test 4a: 0,07A; test 4b: 0,01A Calculated power factor ...... : 0,813 ⎯ Table: measured temperatures corrected for ta = 45 °C: P - abnormal operating mode ...... : Test 4a: S/C one LED; ⎯ Test 4b: S/C output of LED driver - test 1: rated voltage ...... : --- ⎯ - test 2: 1,06 times rated voltage or 1,05 times 240V x1,06=254,4V ⎯ rated wattage ...... : - test 3: Load on wiring to socket-outlet, ⎯ 1,06 times voltage or 1,05 times wattage ...... : - test 4: 1,1 times rated voltage or 1,05 times 240V x1,1=264V ⎯ rated wattage ...... : Through wiring or looping-in wiring loaded by a ⎯ current of A during the test ...... :

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.:00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 26 of 36 http://www.tuv-sud.cn P.R.China

IEC 60598-2-2 Clause Requirement + Test Result - Remark Verdict

temperature (°C) of part Clause 12.4 – normal Clause 12.5 – abnormal test 1 test 2 test 3 limit test 4a Test 4b limit Input wire of LED power ⎯ 59,7 ⎯ 90 ⎯ ⎯ ⎯ supply Output wire of LED power ⎯ 60,4 ⎯ 90 ⎯ ⎯ ⎯ supply tc of LED power supply ⎯ 67,0 ⎯ 75 66,9 51,3 75+10 The max. temperature point ⎯ 61,7 ⎯ 75 ⎯ ⎯ ⎯ of LED power supply top surface Mounting surface under the ⎯ 70,9 ⎯ 90 70,7 52,4 130 LED power supply Supply wire to LED module ⎯ 68,1 ⎯ 90 ⎯ ⎯ ⎯ Cord anchorage ⎯ 66,0 ⎯ Ref. ⎯ ⎯ ⎯ Heat-shrinkable tubing ⎯ 66,8 ⎯ 125 ⎯ ⎯ ⎯ LED module ⎯ 72,9 ⎯ Ref. 73,2 50,9 Ref. Contact point between ⎯ 68,1 ⎯ 90 68,0 48,8 130 ceiling and luminaire Test recess on top of ⎯ 61,2 ⎯ 90 61,3 59,6 130 luminaire Surface of plastic cover ⎯ 53,9 ⎯ Ref. ⎯ ⎯ ⎯ Lighted surface (10 cm) ⎯ 46,3 ⎯ 90 46,1 47,3 175

Type reference ...... : LED DL-RC-HR R120 9W-GP ⎯ Lamp used ...... : LED (16x 0,5W) ⎯ Lamp control gear used ...... : OP-DY220/8-150CC ⎯ Mounting position of luminaire ...... : Fixing on the test recess ⎯ Supply wattage (W) ...... : Test 2: 8,6W; ⎯ test 4a: 8,5W; test 4b:0,01W Supply current (A) ...... : Test 2: 0,04A; ⎯ test 4a: 0,04A; test 4b:0,01A Calculated power factor ...... : 0,748 ⎯ Table: measured temperatures corrected for ta = 45 °C: P - abnormal operating mode ...... : Test 4a: S/C one LED; ⎯ Test 4b: S/C output of LED driver

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.:00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 27 of 36 http://www.tuv-sud.cn P.R.China

IEC 60598-2-2 Clause Requirement + Test Result - Remark Verdict

- test 1: rated voltage ...... : --- ⎯ - test 2: 1,06 times rated voltage or 1,05 times 240V x1,06=254,4V ⎯ rated wattage ...... : - test 3: Load on wiring to socket-outlet, ⎯ 1,06 times voltage or 1,05 times wattage ...... : - test 4: 1,1 times rated voltage or 1,05 times 240V x1,1=264V ⎯ rated wattage ...... : Through wiring or looping-in wiring loaded by a ⎯ current of A during the test ...... :

temperature (°C) of part Clause 12.4 – normal Clause 12.5 – abnormal test 1 test 2 test 3 limit test 4a Test 4b limit Input wire of LED power ⎯ 47,7 ⎯ 90 ⎯ ⎯ ⎯ supply Output wire of LED power ⎯ 64,3 ⎯ 75 ⎯ ⎯ ⎯ supply tc of LED power supply ⎯ 62,1 ⎯ 90 61,9 48,3 75+10 The max. temperature point ⎯ 60,1 ⎯ 90 ⎯ ⎯ ⎯ of LED power supply top surface Mounting surface under the ⎯ 67,2 ⎯ 90 70,7 45,8 90 LED power supply Supply wire to LED module ⎯ 59,7 ⎯ Ref. ⎯ ⎯ ⎯ Cord anchorage ⎯ 71,4 ⎯ Ref. ⎯ ⎯ ⎯ Heat-shrinkable tubing ⎯ 79,1 ⎯ Ref. ⎯ ⎯ ⎯ LED module ⎯ 73,5 ⎯ Ref. 73,2 56,9 Ref. Contact point between ⎯ 55,7 ⎯ 90 56,1 47,4 130 ceiling and luminaire Test recess on top of ⎯ 63,8 ⎯ 90 61,3 51,0 130 luminaire Surface of plastic cover ⎯ 56,5 ⎯ 90 ⎯ ⎯ ⎯ Lighted surface (10 cm) ⎯ 46,3 ⎯ 130 45,0 47,3 175

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.:00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 28 of 36 http://www.tuv-sud.cn P.R.China

IEC 60598-2-2 Clause Requirement + Test Result - Remark Verdict

Type reference ...... : LED DL-RC-HM R210 29W-GP ⎯ Lamp used ...... : LED (11x 0,5W) ⎯ Lamp control gear used ...... : OP-DY220/7-150CC ⎯ Mounting position of luminaire ...... : Fixing on the test recess ⎯ Supply wattage (W) ...... : Test 2: 5,6W; ⎯ test 4a: 5,5W; test 4b: 0,01A Supply current (A) ...... : Test 2: 0,04A; ⎯ test 4a: 0,04A; test 4b: 0,01A Calculated power factor ...... : 0,740 ⎯ Table: measured temperatures corrected for ta = 45 °C: P - abnormal operating mode ...... : Test 4a: S/C one LED; ⎯ Test 4b: S/C output of LED driver - test 1: rated voltage ...... : --- ⎯ - test 2: 1,06 times rated voltage or 1,05 times 240V x1,06=254,4V ⎯ rated wattage ...... : - test 3: Load on wiring to socket-outlet, ⎯ 1,06 times voltage or 1,05 times wattage ...... : - test 4: 1,1 times rated voltage or 1,05 times 240V x1,1=264V ⎯ rated wattage ...... : Through wiring or looping-in wiring loaded by a ⎯ current of A during the test ...... :

temperature (°C) of part Clause 12.4 – normal Clause 12.5 – abnormal test 1 test 2 test 3 limit test 4a Test 4b limit Input wire of LED power ⎯ 48,7 ⎯ 90 ⎯ ⎯ ⎯ supply Output wire of LED power ⎯ 60,3 ⎯ 75 ⎯ ⎯ ⎯ supply tc of LED power supply ⎯ 55,2 ⎯ 65 72,5 47,5 65+10 The max. temperature point ⎯ 61,1 ⎯ 90 ⎯ ⎯ ⎯ of LED power supply top surface Mounting surface under the ⎯ 67,9 ⎯ 90 67,7 46,3 130 LED power supply Supply wire to LED module ⎯ 55,7 ⎯ Ref. ⎯ ⎯ ⎯ Cord anchorage ⎯ 67,4 ⎯ Ref. ⎯ ⎯ ⎯

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.:00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 29 of 36 http://www.tuv-sud.cn P.R.China

IEC 60598-2-2 Clause Requirement + Test Result - Remark Verdict

Heat-shrinkable tubing ⎯ 75,1 ⎯ Ref. ⎯ ⎯ ⎯ LED module ⎯ 86,8 ⎯ Ref. 86,8 86,8 Ref. Contact point between ⎯ 57,7 ⎯ 90 58,0 48,0 130 ceiling and luminaire Test recess on top of ⎯ 59,8 ⎯ 90 58,8 49,0 130 luminaire Surface of plastic cover ⎯ 52,5 ⎯ 90 ⎯ ⎯ ⎯ Lighted surface (10 cm) ⎯ 49,5 ⎯ 130 48,5 46,5 1752

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.:00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 30 of 36 http://www.tuv-sud.cn P.R.China

IEC 60598-2-2 Clause Requirement + Test Result - Remark Verdict

ANNEX 3: screw terminals (part of the luminaire) N/A

(14) SCREW TERMINALS N/A (14.2) Type of terminal ...... : ⎯ Rated current (A) ...... : ⎯ (14.3.2.1) One or more conductors N/A (14.3.2.2) Special preparation N/A (14.3.2.3) Terminal size N/A Cross-sectional area (mm²) ...... : N/A (14.3.3) Conductor space (mm) ...... : N/A (14.4) Mechanical tests N/A (14.4.1) Minimum distance N/A (14.4.2) Cannot slip out N/A (14.4.3) Special preparation N/A (14.4.4) Nominal diameter of thread (metric ISO thread) .. : M N/A External wiring N/A No soft metal N/A (14.4.5) Corrosion N/A (14.4.6) Nominal diameter of thread (mm) ...... : N/A Torque (Nm) ...... : N/A (14.4.7) Between metal surfaces N/A Lug terminal N/A Mantle terminal N/A Pull test; pull (N) ...... : N/A (14.4.8) Without undue damage N/A

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.:00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 31 of 36 http://www.tuv-sud.cn P.R.China

IEC 60598-2-2 Clause Requirement + Test Result - Remark Verdict

ANNEX 4: screwless terminals (part of the luminaire) N/A

(15) SCREWLESS TERMINALS N/A (15.2) Type of terminal ...... : ⎯ Rated current (A) ...... : ⎯ (15.3.1) Material N/A (15.3.2) Clamping N/A (15.3.3) Stop N/A (15.3.4) Unprepared conductors N/A (15.3.5) Pressure on insulating material N/A (15.3.6) Clear connection method N/A (15.3.7) Clamping independently N/A (15.3.8) Fixed in position N/A (15.3.10) Conductor size N/A Type of conductor N/A (15.5.1) Terminals internal wiring N/A (15.5.1.1) Pull test spring-type terminals (4 N, N/A 4 samples)….: (15.5.1.2) Pull test pin or tab terminals (4 N, N/A 4 samples)……: Insertion force not exceeding 50 N N/A (15.5.2) Permanent connections: pull-off test (20 N) N/A (15.6) Electrical tests N/A Voltage drop (mV) after 1 h (4 samples) ...... : N/A Voltage drop of two inseparable joints N/A Number of cycles...... : ⎯ Voltage drop (mV) after 10th alt. 25th cycle N/A (4 samples) ...... : Voltage drop (mV) after 50th alt. 100th cycle N/A (4 samples) ...... : After ageing, voltage drop (mV) after 10th alt. N/A 25th cycle (4 samples) ...... : After ageing, voltage drop (mV) after 50th alt. N/A 100th cycle (4 samples) ...... :

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.:00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 32 of 36 http://www.tuv-sud.cn P.R.China

IEC 60598-2-2 Clause Requirement + Test Result - Remark Verdict

(15.7) Terminals external wiring N/A Terminal size and rating N/A (15.8.1) Pull test spring-type terminals or welded N/A connections (4 samples); pull (N) ...... : Pull test pin or tab terminals (4 samples); N/A pull (N) ...... : (15.9) Contact resistance test N/A Voltage drop (mV) after 1 h N/A terminal 1 2 3 4 5 6 7 8 9 10 voltage drop (mV) Voltage drop of two inseparable joints N/A Voltage drop after 10th alt. 25th cycle N/A Max. allowed voltage drop (mV) ...... : ⎯ terminal 1 2 3 4 5 6 7 8 9 10 voltage drop (mV) Voltage drop after 50th alt. 100th cycle N/A Max. allowed voltage drop (mV) ...... : ⎯ terminal 1 2 3 4 5 6 7 8 9 10 voltage drop (mV) Continued ageing: voltage drop after 10th alt. 25th cycle N/A Max. allowed voltage drop (mV) ...... : ⎯ terminal 1 2 3 4 5 6 7 8 9 10 voltage drop (mV) Continued ageing: voltage drop after 50th alt. 100th cycle N/A Max. allowed voltage drop (mV) ...... : ⎯ terminal 1 2 3 4 5 6 7 8 9 10 voltage drop (mV)

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.:00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 33 of 36 http://www.tuv-sud.cn P.R.China

IEC 60598-2-2 Clause Requirement + Test Result - Remark Verdict

EN 60598-1:2008/A11:2009 Replace Definition 1.2.76 with: 1.2.76 P Impulse withstand categories (former term Category II P overvoltage categories”)

Table 44.B – Required rated impulse withstand voltage of equipment

Nominal voltage of the Required impulse withstand voltage for P installation a kV c V Three- Single-phase Equipment at Equipment of Appliances Specially --- phase systems with the origin of distribution and and current- protected systems b middle point the installation final circuits using (overvolta (overvoltage (overvoltage equipment ge category IV) category III) (overvoltage category I) category II) - 120-240 4 2.5 1.5 0.8 N/A 230/400 - 6 4 2.5 1.5 P 277/480 400/690 - 8 6 4 2.5 N/A 1000 - 12 8 6 4 N/A a According to IEC 60038.

b In Canada and USA, for voltages to earth higher than 300V, the impulse withstand voltage corresponding to the next highest voltage in column one applies.

c This impulse withstand voltage is applied between live conductors and PE.

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.:00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 34 of 36 http://www.tuv-sud.cn P.R.China

IEC 60598-2-2 Clause Requirement + Test Result - Remark Verdict

European Group Differences and National Differences P

ATTACHMENT TO TEST REPORT IEC 60598-2-2 EUROPEAN GROUP DIFFERENCES AND NATIONAL DIFFERENCES Luminaires Part 2: Particular requirements: Section Two – Recessed luminaires Differences according ...... : EN 60598-2-2:2012 used in conjunction with EN 60598-1:2008 + A11:2009 Annex Form No...... : EU_GD_IEC_60598_2_2B Annex Form Originator ...... : IMQ S.p.A. Master Annex Form ...... : 2012-02 Copyright © 2009 IEC System for Conformity Testing and Certification of Electrical Equipment (IECEE), Geneva, Switzerland. All rights reserved.

CENELEC COMMON MODIFICATIONS (EN) P

2.5 (3) MARKING P 2.5 (3.3.101) Adequate warning on the package P

2.6 (4) CONSTRUCTION P 2.6 (4.11.6) Electro-mechanical contact systems N/A

2.10 (5) EXTERNAL AND INTERNAL WIRING P 2.10 (5.2.1) Connecting leads P - without a means for connection to the supply P - terminal block specified N/A - relevant information provided P - compliance with 4.6, 4.7.1, 4.7.2, 4.10.1, 11.2, N/A 12 and 13.2 of Part 1 2.10 (5.2.2) Cables equal to HD21 S2 or HD22 S2 P

2.12 (12) ENDURANCE TEST AND THERMAL TEST P 2.12 (12.4.2c) Thermal test (normal operation) P

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.:00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 35 of 36 http://www.tuv-sud.cn P.R.China

IEC 60598-2-2 Clause Requirement + Test Result - Remark Verdict

ZB ANNEX ZB, SPECIAL NATIONAL CONDITIONS (EN) N/A (3.3) DK: power supply cord with label N/A IT: warning label on Class 0 luminaire N/A (4.5.1) DK: socket-outlets N/A (5.2.1) CY, DK, FI, SE, GB: type of plug N/A

ZC ANNEX ZC, NATIONAL DEVIATIONS (EN) N/A (4 & 5) FR: Shuttered socket-outlets 10/16A N/A FR: Glow-wire test 850°C alt. 750°C for (13.3) luminaires in premises open to public or 960°C N/A for luminaires in emergency exits GB: Requirements according to United Kingdom (13.3) N/A Building Regulation

---End of Report---

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.:00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 36 of 36 http://www.tuv-sud.cn P.R.China

Attachment 1 IEC/EN 62031 Clause Requirement − Test Result − Remark Verdict

4 GENERAL REQUIREMENTS P 4.4 Integral modules treated as part of luminaires Ceramic board of the Integral P defined in clause 0.5 of IEC 60598-1 module 4.5 Independent modules complies with requirements N/A in IEC 60598-1

5 GENERAL TEST REQUIREMENTS N/A 5.5 SELV-operated LED modules comply with Annex I (see Annex B) N/A of IEC 61347-2-13

6 CLASSIFICATION P Built-in module ...... : Yes No ⎯ Independent module ...... : Yes No ⎯ Integral module ...... : Yes No ⎯ For Integral module; Note to 1.2.1 in IEC 60598-1 P applies.

7 MARKING N/A 7.1 Mandatory markings: N/A - mark of origin N/A - model number, type reference ...... : N/A - rated supply voltage (V) ...... : N/A - rated supply current (A) ...... : N/A - rated input power (V) ...... : N/A - nominal power N/A - indication of connections, wiring diagram N/A

- value of tc N/A - eye protection N/A - marking of built-in modules only N/A 7.2 - location of marking N/A 7.3 Marking durable and legible N/A Rubbing 15 s water, marking legible N/A

8 SCREW TERMINALS N/A Compliance with section 14 of IEC 60598-1 N/A SCREWLESS TERMINALS N/A Compliance with section 15 of IEC 60598-1 N/A CONNECTORS N/A Compliance with IEC 60838-2-2 N/A

9 PROVISION FOR PROTECTIVE EARTHING N/A External metal parts connected to the earth terminal: N/A - compliance with 7.2.1 in IEC 60598-1 N/A Test with a current of 10 A between earthing N/A terminal and each of the accessible metal parts; measured resistance (Ω): < 0,5 Ω ...... : Protective earth, symbol N/A Terminal complying with clause 8 in Part 1 N/A

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.:00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 1 of 6 http://www.tuv-sud.cn P.R.China

Attachment 1 IEC/EN 62031 Clause Requirement − Test Result − Remark Verdict

Locked against loosening and not possible to N/A loosen by hand Not possible to loosen clamping means N/A unintentionally on screwless terminals Earthing via means of fixing N/A Earthing terminal only used for the earthing of the N/A control gear All parts of material minimizing the danger of N/A electrolytic corrosion Made of brass or equivalent material N/A Contact surface bare metal N/A Conductors by tracks on printed circuit boards: - a.c. current of 25 A for 1 min between earthing N/A terminal and accessible metal parts - compliance with clause 7.2.1 in IEC 60598-1 N/A

8 (10) PROTECTION AGAINST ACCIDENTAL CONTACT WITH LIVE PARTS P Protection against accidental contact with live parts in compliance with IEC 61347-1 P (clause numbers between parentheses refer to IEC 61347-1) - (10.1) Controlgear protected against accidental contact Ref. to the Attachment 5: IEC P with live parts 61347-2-13 Test report - (A1) Current measured according to IEC 60990, figure 4 N/A and clause 7.1: max. 0,7 mA (peak) or 2,0 mA d.c., for f ≥ 1000 Hz max. 70 mA ...... : - (A2) Voltage at 50 kΩ (V): max. 34 V (peak) ...... : N/A Lacquer or enamel not used for protection or N/A insulation Adequate mechanical strength on parts providing N/A protection - (10.2) Capacitors > 0,5 μF: voltage after 1 min (V): < 50 V N/A ...... : 8.1 (-) SELV-equivalent controlgear accessible parts are N/A insulated from live parts by double or reinforced insulation according 8.6 and 13.1 in IEC 60065 8.2 (-) Exposed terminals of SELV or SELV-equivalent N/A controlgear are allowed if: - the rated or maximum output voltage does not exceeding 25 V r.m.s. - the no-load output voltage does not exceed 30 V r.m.s. or 33 √2 V peak Insulated terminals if rated output voltage >25 V N/A One capacitor Y1 or two capacitors Y2 of the same N/A values used in series between SELV or SELV- equivalent output and primary circuits - Capacitor complying with IEC 60384-14 - Other components bridging the separating transformer complying with EN 60065, clause 14

11 MOISTURE RESISTANCE AND INSULATION P

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.:00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 2 of 6 http://www.tuv-sud.cn P.R.China

Attachment 1 IEC/EN 62031 Clause Requirement − Test Result − Remark Verdict

Protection against moisture and insulation in compliance with Clause 11, IEC 61347-1 P After storage 48 h at 91-95% relative humidity and >10 MΩ P 20-30 °C measuring of insulation resistance with d.c. 500 V (MΩ): ≥ 2 MΩ ...... : Adequate insulation between input and output N/A terminals not bounded together in SELV-equivalent controlgear For double or reinforced insulation the resistance P exceeds 4 MΩ 12 ELECTRIC STRENGTH P Electric strength in compliance with Clause 12 of IEC 61347-1 P Immediately after clause 11 electric strength test for 1 min P Working voltage ≤ 42 V, test voltage 500 V N/A Working voltage > 42 V, test voltage (V): 1560V P 2U + 1000 V ...... : (LED driver max output 280V) Reinforced insulation, test voltage (V): ...... : 4480V P (LED driver max output 280V) No flashover or breakdown P Windings in separating transformers in SELV- P equivalent control gear according to 14.3.2 of EN 60065

13 FAULT CONDITIONS P 13.1 In compliance with IEC 61347-1 (clause numbers between parentheses refer to P IEC 61347-1) When operated under fault conditions the LED-module: P - does not emit flames or molten material P - does not produce flammable gases P - protection against accidental contact not impaired P Thermally protected controlgear does not exceed N/A the marked temperature value Fault conditions: capacitors, resistors or inductors (see appended table) N/A without proof of compliance with relevant specifications have been short-circuited or disconnected - (14.1) Short-circuit of creepage distances and clearances (see appended table) P if less than specified in clause 16 in Part 1 (except S/C one LED and S/C LED between live parts and accessible metal parts) module, see ANNEX 2 Distances on printed boards provided with coating P according to IEC 60664-3 - (14.2) Short-circuit or interruption of semiconductor (see appended table) N/A devices

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.:00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 3 of 6 http://www.tuv-sud.cn P.R.China

Attachment 1 IEC/EN 62031 Clause Requirement − Test Result − Remark Verdict

- (14.3) Short-circuit across insulation consisting of lacquer, (see appended table) N/A enamel or textile - (14.4) Short-circuit across electrolytic capacitors (see appended table) N/A - (14.5) During the tests, a five-layer tissue paper, where P the test specimen is wrapped, does not ignite After the tests the insulation resistance with d.c. > 1 MΩ P 500 V (MΩ) are ≥ 1 MΩ ...... : Temperature declared thermally protected LED- N/A modules fulfil the requirements in Annex C of IEC 61437-1 13.2 Module withstands overpower condition >15 min. P Module with automatic protective device or power P limiter, test performed 15 min. at limit. During the tests, tissue paper, spread below P module, does not ignite

15 CONSTRUCTION P Wood, cotton, silk, paper and similar fibrous P material not used as insulation

16 CREEPAGE DISTANCES AND CLEARANCES P Creepage and distances and clearances in compliance with IEC 60598-1 P Class of protection ...... : Class II — Working voltage (V) ...... : Max. 280V of LED LED DL-RC- — HR R210 42W-GP Voltage form ...... : Sinusoidal / Non-sinusoidal — PTI ...... : < 600 / 600 — Rated pulse voltage (kV) ...... : — (1) Live parts of different polarity: cr (mm); cl (mm) N/A ...... : (2) Live parts and accessible parts: cr (mm); cl Cr/cl: 7,3 mm /7,3 mm P (mm) ...... : Limit Cr/Cl: 6,0 mm / 6,0 mm (3) Parts becoming live: cr (mm); cl (mm) ... : N/A (4) Outer surface of cable: cr (mm); cl (mm) : N/A (5) Live parts of switches: cr (mm); cl (mm) : N/A (6) Live parts and supporting surface: cr (mm); cl Cr/cl: 7,3 mm /7,3 mm P (mm) ...... : Limit Cr/Cl: 6,0 mm / 6,0 mm

17 (17) SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS P

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.:00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 4 of 6 http://www.tuv-sud.cn P.R.China

Attachment 1 IEC/EN 62031 Clause Requirement − Test Result − Remark Verdict

Screws, current-carrying parts and connections in compliance with IEC 60598-1 P (clause numbers between parentheses refer to IEC 60598-1) (4.11) Electrical connections: P (4.11.1) Contact pressure N/A (4.11.2) Screws: N/A - self-tapping screws N/A - thread-cutting screws N/A - at least two self-tapping screws N/A (4.11.3) Screw locking: N/A - spring washer N/A - rivets N/A (4.11.4) Material of current-carrying parts P (4.11.5) No contact to wood P (4.12) Mechanical connections and glands: P (4.12.1) Mechanical stress P Screws not made of soft metal P Screws of insulating material N/A Torque test: part; torque (Nm) ...... : Screw fixing the LED module P Torque test: part; torque (Nm) ...... : N/A Torque test: part; torque (Nm) ...... : N/A (4.12.2) Screw diameter < 3 mm screwed into metal P (4.12.3) Void ⎯ (4.12.4) Locked connections N/A (4.12.5) Screwed glands: force (N) ...... : N/A

18 (18) RESISTANCE TO HEAT, FIRE AND TRACKING N/A Resistance to Heat, Fire and Tracking in compliance with IEC 61347-1 (clause N/A numbers between parentheses refer to IEC 61347-1) (18.1) Parts of insulating material retaining live parts in position, ball-pressure test: N/A - part; test temperature (°C) ...... : N/A - part; test temperature (°C) ...... : N/A (18.2) Printed boards in accordance with IEC 60249-1, 4.3 N/A (18.3) External parts of insulating material preventing N/A electric shock glow-wire test 650 °C

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.:00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 5 of 6 http://www.tuv-sud.cn P.R.China

Attachment 1 IEC/EN 62031 Clause Requirement − Test Result − Remark Verdict

(18.4) Parts of insulating material retaining live parts in position, needle-flame test 10 s: N/A - flame extinguished within 30 s N/A - no flaming drops igniting tissue paper N/A (18.5) Tracking test N/A

19 RESISTANCE TO CORROSION N/A Resistance to corrosion in compliance with IEC 61347-1 N/A Rust protection: N/A - test according 4.18.1 of IEC 60598-1 N/A - adequate varnish on the outer surface N/A

14 TABLE: tests of fault conditions N/A Part Simulated fault Hazard

S/C one LED LEDs weren’t work NO

A ANNEX A - TESTS P All tests performed in accordance with the advise P given in Annex H of IEC 61347-1, if applicable

B ANNEX B - SELV-operated LED modules N/A ANNEX I of IEC 61347-2-13 - PARTICULAR ADDITIONAL REQUIREMENTS FOR N/A INDEPENDENT SELV D.C. OR A.C. SUPPLIED ELECTRONIC STEP-DOWN CONVERTORS FOR FILAMENT LAMPS

Conformity testing during manufacture Annex C (informative) This test is carried out at 100 % of production. It is combined with the measurement of input power at P rated voltage/current. The luminous flux of no module should be significantly lower than that of the rest of the production. NOTE Very low values of the luminous flux indicate internal losses that may be safety relevant, like N/A current bridges. For independent and built-in modules, IEC 60598-1, P Annex Q, is applicable, but without polarity check.

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.:00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 6 of 6 http://www.tuv-sud.cn P.R.China

Attachment 2 IEC 62471 Clause Requirement + Test Result – Remark Verdict

4 EXPOSURE LIMITS P 4.1 General P The exposure limits in this standard is not less than P 0,01 ms and not more than any 8-hour period and should be used as guides in the control of exposure Detailed spectral data of a light source are generally P required only if the luminance of the source exceeds see clause 4.3 104 cd.m-2 4.3 Hazard exposure limits P 4.3.1 Actinic UV hazard exposure limit for the skin and eye P The exposure limit for effective radiant exposure is P 30 J.m-2 within any 8-hour period To protect against injury of the eye or skin from ul- P traviolet radiation exposure produced by a broad- band source, the effective integrated spectral ir- radiance , ES, of the light source shall not exceed the levels defined by: P

The permissible time for exposure to ultraviolet ra- P diation incident upon the unprotected eye or skin shall be computed by: P

4.3.2 Near-UV hazard exposure limit for eye P For the spectral region 315 nm to 400 nm (UV-A) the P total radiant exposure to the eye shall not exceed 10000 J.m-2 for exposure times less than 1000 s. For exposure times greater than 1000 s (approximately 16 minutes) the UV-A irradiance for the unprotected . -2 eye, EUVA, shall not exceed 10 W m . The permissible time for exposure to ultraviolet ra- P diation incident upon the unprotected eye for time less than 1000 s, shall be computed by: P

4.3.3 Retinal blue light hazard exposure limit P

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Pin- Rev.:00 Telefax : +86 20 38320478 gyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 1 of 14 http://www.tuv-sud.cn P.R.China

Attachment 2 IEC 62471 Clause Requirement + Test Result – Remark Verdict

To protect against retinal photochemical injury from P chronic blue-light exposure, the integrated spectral radiance of the light source weighted against the blue-light hazard function, B(λ), i.e., the blue-light weighted radiance , LB, shall not exceed the levels defined by: N/A for t ≤ 104 s

P for t > 104 s

4.3.4 Retinal blue light hazard exposure limit - small source N/A

Thus the spectral irradiance at the eye Eλ, weighted N/A against the blue-light hazard function B(λ) shall not see table 4.2 exceed the levels defined by: N/A for t ≤ 100 s

N/A for t > 100 s

4.3.5 Retinal thermal hazard exposure limit P To protect against retinal thermal injury, the inte- P grated spectral radiance of the light source, Lλ, weighted by the burn hazard weighting function R(λ) (from Figure 4.2 and Table 4.2), i.e., the burn hazard weighted radiance, shall not exceed the levels de- fined by: P (10 μs ≤ t ≤ 10 s)

4.3.6 Retinal thermal hazard exposure limit – weak visual stimulus N/A For an infrared heat lamp or any near-infrared source N/A where a weak visual stimulus is inadequate to acti- vate the aversion response, the near infrared (780 nm to 1400 nm) radiance, LIR, as viewed by the eye for exposure times greater than 10 s shall be limited to: N/A t > 10 s

4.3.7 Infrared radiation hazard exposure limits for the eye P

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Pin- Rev.:00 Telefax : +86 20 38320478 gyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 2 of 14 http://www.tuv-sud.cn P.R.China

Attachment 2 IEC 62471 Clause Requirement + Test Result – Remark Verdict

The avoid thermal injury of the cornea and possible P delayed effects upon the lens of the eye (catarac- togenesis), ocular exposure to infrared radiation, EIR, over the wavelength range 780 nm to 3000 nm, for times less than 1000 s, shall not exceed: N/A t ≤ 1000 s

For times greater than 1000 s the limit becomes: P P t > 1000 s

4.3.8 Thermal hazard exposure limit for the skin P Visible and infrared radiant exposure (380 nm to P 3000 nm) of the skin shall be limited to: P

5 MEASUREMENT OF LAMPS AND LAMP SYSTEMS P 5.1 Measurement conditions P Measurement conditions shall be reported as part of P the evaluation against the exposure limits and the assignment of risk classification. 5.1.1 Lamp ageing (seasoning) 1h P Seasoning of lamps shall be done as stated in the P appropriate IEC lamp standard. 5.1.2 Test environment P For specific test conditions, see the appropriate IEC P lamp standard or in absence of such standards, the appropriate national standards or manufacturer’s recommendations. 5.1.3 Extraneous radiation P Careful checks should be made to ensure that ex- P traneous sources of radiation and reflections do not add significantly to the measurement results. 5.1.4 Lamp operation P Operation of the test lamp shall be provided in ac- P cordance with: – the appropriate IEC lamp standard, or N/A

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Pin- Rev.:00 Telefax : +86 20 38320478 gyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 3 of 14 http://www.tuv-sud.cn P.R.China

Attachment 2 IEC 62471 Clause Requirement + Test Result – Remark Verdict

– the manufacturer’ s recommendation P 5.1.5 Lamp system operation N/A The power source for operation of the test lamp shall N/A be provided in accordance with: – the appropriate IEC standard, or N/A – the manufacturer’ s recommendation N/A 5.2 Measurement procedure P 5.2.1 Irradiance measurements P Minimum aperture diameter 7mm. P Maximum aperture diameter 50 mm. P The measurement shall be made in that position of P the beam giving the maximum reading. The measurement instrument is adequate calibrated. P 5.2.2 Radiance measurements P 5.2.2.1 Standard method N/A The measurements made with an optical system. N/A The instrument shall be calibrated to read in absolute N/A radiant power per unit receiving area and per unit solid angle to acceptance averaged over the field of view of the instrument. 5.2.2.2 Alternative method P Alternatively to an imaging radiance set-up, an ir- P radiance measurement set-up with a circular field stop placed at the source can be used to perform radiance measurements. 5.2.3 Measurement of source size P The determination of α, the angle subtended by a P source, requires the determination of the 50% emis- sion points of the source. 5.2.4 Pulse width measurement for pulsed sources N/A The determination of ∆t, the nominal pulse duration N/A of a source, requires the determination of the time during which the emission is > 50% of its peak value. 5.3 Analysis methods P 5.3.1 Weighting curve interpolations P

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Pin- Rev.:00 Telefax : +86 20 38320478 gyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 4 of 14 http://www.tuv-sud.cn P.R.China

Attachment 2 IEC 62471 Clause Requirement + Test Result – Remark Verdict

To standardize interpolated values, use linear in- P terpolation on the log of given values to obtain in- see table 4.1 termediate points at the wavelength intervals de- sired. 5.3.2 Calculations P The calculation of source hazard values shall be P performed by weighting the spectral scan by the appropriate function and calculating the total weighted energy. 5.3.3 Measurement uncertainty N/A

The quality of all measurement results must be N/A quantified by an analysis of the uncertainty.

6 LAMP CLASSIFICATION P

For the purposes of this standard it was decided that see table 6.1 P the values shall be reported as follows: – for lamps intended for general lighting service, Test condition: Normal opera- P the hazard values shall be reported as either ir- tion radiance or radiance values at a distance which Make the axis of light source produces an illuminance of 500 lux, but not at a coincided with the sensor’s distance less than 200 mm – for all other light sources, including pulsed lamp N/A sources, the hazard values shall be reported at a distance of 200 mm 6.1 Continuous wave lamps P 6.1.1 Exempt Group P In the exempt group lamps, which do not pose any P photobiological hazard. The requirement is met by any lamp that does not pose:

– an actinic ultraviolet hazard (ES) within 8-hours P exposure (30000 s), nor

– a near-UV hazard (EUVA) within 1000 s, (about 16 P min), nor

– a retinal blue-light hazard (LB) within 10000 s P (about 2,8 h), nor

– a retinal thermal hazard (LR) within 10 s, nor P

– an infrared radiation hazard for the eye (EIR) P within 1000 s 6.1.2 Risk Group 1 (Low-Risk) N/A

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Pin- Rev.:00 Telefax : +86 20 38320478 gyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 5 of 14 http://www.tuv-sud.cn P.R.China

Attachment 2 IEC 62471 Clause Requirement + Test Result – Remark Verdict

In this group are lamps, which exceeds the limits for N/A the except group but that does not pose:

– an actinic ultraviolet hazard (ES) within 10000 s, N/A nor

– a near ultraviolet hazard (EUVA) within 300 s, nor N/A

– a retinal blue-light hazard (LB) within 100 s, nor N/A

– a retinal thermal hazard (LR) within 10 s, nor N/A

– an infrared radiation hazard for the eye (EIR) N/A within 100 s Lamps that emit infrared radiation without a strong N/A visual stimulus and do not pose a near-infrared retinal hazard (LIR), within 100 s are in Risk Group 1. 6.1.3 Risk Group 2 (Moderate-Risk) N/A This requirement is met by any lamp that exceeds N/A the limits for Risk Group 1, but that does not pose:

– an actinic ultraviolet hazard (ES) within 1000 s N/A exposure, nor

– a near ultraviolet hazard (EUVA) within 100 s, nor N/A

– a retinal blue-light hazard (LB) within 0,25 s N/A (aversion response), nor

– a retinal thermal hazard (LR) within 0,25 s (aver- N/A sion response), nor

– an infrared radiation hazard for the eye (EIR) N/A within 10 s Lamps that emit infrared radiation without a strong N/A visual stimulus and do not pose a near-infrared retinal hazard (LIR), within 10 s are in Risk Group 2. 6.1.4 Risk Group 3 (High-Risk) N/A Lamps which exceed the limits for Risk Group 2 are N/A in Group 3. 6.2 Pulsed lamps N/A Pulse lamp criteria shall apply to a single pulse and N/A to any group of pulses within 0,25 s. A pulsed lamp shall be evaluated at the highest N/A nominal energy loading as specified by the manu- facturer. The risk group determination of the lamp being N/A tested shall be made as follows:

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Pin- Rev.:00 Telefax : +86 20 38320478 gyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 6 of 14 http://www.tuv-sud.cn P.R.China

Attachment 2 IEC 62471 Clause Requirement + Test Result – Remark Verdict

– a lamp that exceeds the exposure limit shall be N/A classified as belonging to Risk Group 3 (High-Risk) – for single pulsed lamps, a lamp whose weighted N/A radiant exposure or weighted radiance does is below the EL shall be classified as belonging to the Exempt Group – for repetitively pulsed lamps, a lamp whose N/A weighted radiant exposure or weighted radiance dose is below the EL, shall be evaluated using the continuous wave risk criteria discussed in clause 6.1, using time averaged values of the pulsed emission

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Pin- Rev.:00 Telefax : +86 20 38320478 gyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 7 of 14 http://www.tuv-sud.cn P.R.China

Attachment 2 IEC 62471 Clause Requirement + Test Result – Remark Verdict

Table 4.1 Spectral weighting function for assessing ultraviolet hazards for skin and eye -- Wavelength1 UV hazard function Wavelength UV hazard function λ, nm SUV(λ) λ, nm SUV(λ) 200 0,030 313* 0,006 205 0,051 315 0,003 210 0,075 316 0,0024 215 0,095 317 0,0020 220 0,120 318 0,0016 225 0,150 319 0,0012 230 0,190 320 0,0010 235 0,240 322 0,00067 240 0,300 323 0,00054 245 0,360 325 0,00050 250 0,430 328 0,00044 254* 0,500 330 0,00041 255 0,520 333* 0,00037 260 0,650 335 0,00034 265 0,810 340 0,00028 270 1,000 345 0,00024 275 0,960 350 0,00020 280* 0,880 355 0,00016 285 0,770 360 0,00013 290 0,640 365* 0,00011 295 0,540 370 0,000093 297* 0,460 375 0,000077 300 0,300 380 0,000064 303* 0,120 385 0,000053 305 0,060 390 0,000044 308 0,026 395 0,000036 310 0,015 400 0,000030 1 Wavelengths chosen are representative: other values should be obtained by logarithmic interpolation at intermediate wavelengths. * Emission lines of a mercury discharge spectrum.

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Pin- Rev.:00 Telefax : +86 20 38320478 gyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 8 of 14 http://www.tuv-sud.cn P.R.China

Attachment 2 IEC 62471 Clause Requirement + Test Result – Remark Verdict

Table 4.2 Spectral weighting functions for assessing retinal hazards from broadband optical -- sources Wavelength Blue-light hazard function Burn hazard function nm B (λ) R (λ) 300 0,01 305 0,01 310 0,01 315 0,01 320 0,01 325 0,01 330 0,01 335 0,01 340 0,01 345 0,01 350 0,01 355 0,01 360 0,01 365 0,01 370 0,01 375 0,01 380 0,01 0,1 385 0,013 0,13 390 0,025 0,25 395 0,05 0,5 400 0,10 1,0 405 0,20 2,0 410 0,40 4,0 415 0,80 8,0 420 0,90 9,0 425 0,95 9,5 430 0,98 9,8 435 1,00 10,0 440 1,00 10,0 445 0,97 9,7 450 0,94 9,4 455 0,90 9,0 460 0,80 8,0 465 0,70 7,0 470 0,62 6,2 475 0,55 5,5 480 0,45 4,5 485 0,32 3,2 490 0,22 2,2 495 0,16 1,6 500-600 10[(450-λ)/50] 1,0 600-700 0,001 1,0

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Pin- Rev.:00 Telefax : +86 20 38320478 gyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 9 of 14 http://www.tuv-sud.cn P.R.China

Attachment 2 IEC 62471 Clause Requirement + Test Result – Remark Verdict

Table 4.2 Spectral weighting functions for assessing retinal hazards from broadband optical -- sources 700-1050 10[(700-λ)/500] 1050-1150 0,2 1150-1200 0,2.100,02(1150-λ) 1200-1400 0,02

Table 5.4 Summary of the ELs for the surface of the skin or cornea (irradiance based values) -- Wavelength Exposure Limiting EL in terms of con- Hazard Relevant equation range duration aperture stant irradiance Name -2 nm sec rad (deg) W•m Actinic UV E = ∑E • S(λ) • ∆λ 200 – 400 < 30000 1,4 (80) 30/t skin & eye S λ ≤1000 10000/t Eye UV-A E = ∑E • ∆λ 315 – 400 1,4 (80) UVA λ >1000 10 Blue-light E = ∑E • B(λ) • ∆λ ≤100 100/t B λ 300 – 700 < 0,011 small source >100 1,0 ≤1000 18000/t 0,75 Eye IR E = ∑E • ∆λ 780 –3000 1,4 (80) IR λ >1000 100

0,75 Skin thermal EH = ∑Eλ • ∆λ 380 – 3000 < 10 2π sr 20000/t

Table 5.5 Summary of the ELs for the retina (radiance based values) -- Wavelength Exposure EL in terms of Field of view Hazard Name Relevant equation range duration constant radiance radians -2 -1 nm sec W•m •sr ) 0,25 – 10 0,011•√(t/10) 106/t 10-100 0,011 106/t Blue light L = ∑L • B(λ) • ∆λ 300 – 700 B λ 100-10000 0,0011•√t 106/t ≥ 10000 0,1 100 Retinal < 0,25 0,0017 50000/(α•t 0,25) L = ∑L • R(λ) • ∆λ 380 – 1400 thermal R λ 0,25 – 10 0,011•√(t/10) 50000/(α•t 0,25) Retinal thermal L = ∑L • R(λ) • ∆λ 780 – 1400 > 10 0,011 6000/α (weak visual IR λ stimulus)

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Pin- Rev.:00 Telefax : +86 20 38320478 gyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 10 of 14 http://www.tuv-sud.cn P.R.China

Attachment 2 EN deviation of IEC 62471-1:2006 Clause Requirement + Test Result – Remark Verdict

IEC 62471 Clause Requirement + Test Result – Remark Verdict

Table 6.1 Emission limits for risk groups of continuous wave lamps Model LED DL-RC-HR R210 42W-GP α=63,36 mrad P Emission Measurement Action Risk Symbol Units Exempt Low risk Mod risk spectrum Limit Result Limit Result Limit Result -2 -3 Actinic UV SUV(λ) Es W•m 1.0x10 0,000 0,003 - 0,03 - -2 -4 Near UV EUVA W•m 10 6,614x 10 33 - 100 - -2 -1 Blue light B(λ) LB W•m •sr 100 17,15 10000 - 4000000 - Blue light, B(λ) E W•m-2 1,0* --- 1,0 - 400 - small source B Retinal R(λ) L W•m-2•sr-1 28000/α 805,7 28000/α - 71000/α - thermal R Retinal thermal, R(λ) L W•m-2•sr-1 6000/α 0,000 6000/α - 6000/α - weak visual IR stimulus** IR radiation, E W•m-2 100 0,000 570 - 3200 - eye IR * Small source defined as one with α < 0,011 radian. Averaging field of view at 10000 s is 0,1 radian. ** Involves evaluation of non-GLS source

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Pingyun Rev.:00 Telefax : +86 20 38320478 Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 11 of 14 http://www.tuv-sud.cn P.R.China

Attachment 2 EN deviation of IEC 62471-1:2006 Clause Requirement + Test Result – Remark Verdict

Table 6.1 Emission limits for risk groups of continuous wave lamps Model LED DL-RC-HR R175 14W-GP, α=54,11mrad P Emission Measurement Action Risk Symbol Units Exempt Low risk Mod risk spectrum Limit Result Limit Result Limit Result

-2 -3 -6 Actinic UV SUV(λ) Es W•m 1.0x10 2,299x 10 0,003 - 0,03 -

-2 -4 Near UV EUVA W•m 10 4,705x 10 33 - 100 -

-2 -1 Blue light B(λ) LB W•m •sr 100 9,442 10000 - 4000000 -

Blue light, B(λ) E W•m-2 1,0* --- 1,0 - 400 - small source B Retinal R(λ) L W•m-2•sr-1 28000/α 514,7 28000/α - 71000/α - thermal R Retinal thermal, R(λ) L W•m-2•sr-1 6000/α 0,000 6000/α - 6000/α - weak visual IR stimulus** IR radiation, E W•m-2 100 0,000 570 - 3200 - eye IR * Small source defined as one with α < 0,011 radian. Averaging field of view at 10000 s is 0,1 radian. ** Involves evaluation of non-GLS source

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Pingyun Rev.:00 Telefax : +86 20 38320478 Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 12 of 14 http://www.tuv-sud.cn P.R.China

Attachment 2 EN deviation of IEC 62471-1:2006 Clause Requirement + Test Result – Remark Verdict

Table 6.1 Emission limits for risk groups of continuous wave lamps Model LED DL-RC-HR R120 9W-GP, α=62,07mrad P Emission Measurement Action Risk Symbol Units Exempt Low risk Mod risk spectrum Limit Result Limit Result Limit Result

-2 -3 -5 Actinic UV SUV(λ) Es W•m 1.0x10 2,288x 10 0,003 - 0,03 -

-2 -4 Near UV EUVA W•m 10 5,085x 10 33 - 100 -

-2 -1 Blue light B(λ) LB W•m •sr 100 11,22 10000 - 4000000 -

Blue light, B(λ) E W•m-2 1,0* --- 1,0 - 400 - small source B Retinal R(λ) L W•m-2•sr-1 28000/α 603,5 28000/α - 71000/α - thermal R Retinal thermal, R(λ) L W•m-2•sr-1 6000/α 0,000 6000/α - 6000/α - weak visual IR stimulus** IR radiation, E W•m-2 100 0,000 570 - 3200 - eye IR * Small source defined as one with α < 0,011 radian. Averaging field of view at 10000 s is 0,1 radian. ** Involves evaluation of non-GLS source

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Pingyun Rev.:00 Telefax : +86 20 38320478 Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 13 of 14 http://www.tuv-sud.cn P.R.China

Attachment 2 EN deviation of IEC 62471-1:2006 Clause Requirement + Test Result – Remark Verdict

Table 6.1 Emission limits for risk groups of continuous wave lamps Model LED DL-RC-HR R100 6W-GP, α=59,20mrad P Emission Measurement Action Risk Symbol Units Exempt Low risk Mod risk spectrum Limit Result Limit Result Limit Result

-2 -3 Actinic UV SUV(λ) Es W•m 1.0x10 0,000 0,003 - 0,03 -

-2 -4 Near UV EUVA W•m 10 6,133x 10 33 - 100 -

-2 -1 Blue light B(λ) LB W•m •sr 100 11,82 10000 - 4000000 -

Blue light, B(λ) E W•m-2 1,0* --- 1,0 - 400 - small source B Retinal R(λ) L W•m-2•sr-1 28000/α 553,5 28000/α - 71000/α - thermal R Retinal thermal, R(λ) L W•m-2•sr-1 6000/α 0,000 6000/α - 6000/α - weak visual IR stimulus** IR radiation, E W•m-2 100 0,000 570 - 3200 - eye IR * Small source defined as one with α < 0,011 radian. Averaging field of view at 10000 s is 0,1 radian. ** Involves evaluation of non-GLS source

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Pingyun Rev.:00 Telefax : +86 20 38320478 Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 14 of 14 http://www.tuv-sud.cn P.R.China

Attachment 3 IEC 61347-2-13 Clause Requirement + Test Result - Remark Verdict

4 (4) GENERAL REQUIREMENTS P Insulation materials according requirements in (see Annex N) N/A Annex N of IEC 61347-1 Compliance of independent controlgear enclosure P with IEC 60598-1 Built-in magnetic ballast with double or reinforced N/A insulation comply with Annex I of IEC 61347-1 Built-in electronic controlgear with double or (see Annex O) N/A reinforced insulation comply with Annex O of IEC 61347-1 SELV controlgear comply with Annex L of (see Annex L) N/A IEC 61347-1 Independent SELV controlgear comply with (see Annex I) N/A Annex I of this part 2

6 (6) CLASSIFICATION P Built-in controlgear ...... : Yes No ⎯ Independent controlgear ...... :Yes No ⎯ Integral controlgear ...... : Yes No ⎯ SELV-equivalent or isolating controlgear ...... : Yes No ⎯ Auto-wound controlgear ...... : Yes No ⎯ Independent SELV controlgear ...... : Yes No ⎯

7 (7) MARKING P 7.1 (7.1) Mandatory markings P a) mark of origin OPPLE P b) model number or type reference See the Copy of marking P plate c) symbol for independent controlgear, if P applicable d) correlation between interchangeable parts and N/A controlgear marked e) rated supply voltage (V) 220-240 V P supply frequency (Hz) 50/60 Hz P supply current (A) Max. 0,21A P f) earthing symbol N/A

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.: 00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 1 of 43 http://www.tuv-sud.cn P.R.China

Attachment 3 IEC 61347-2-13 Clause Requirement + Test Result - Remark Verdict

k) wiring diagram P

l) value of tc tc: 75°C P m) symbol for declared temperature N/A

Constant voltage type: Yes No ⎯ - rated output voltage (V) ...... : N/A Constant current type: Yes No ⎯ - rated output current (A) ...... : 150mA P - rated maximum output voltage (V) ...... : Max. 400V (no load output P voltage of model OP- DY220/40-150CC) - indication if for LED modules only P 7.1 (7.2) Marking durable and legible P Rubbing 15 s water, 15 s petroleum; marking Still legible, No curling P legible 7.2 (7.1) Information to be provided, if applicable: P h) declaration on protection against accidental P contact i) cross-section of conductors (mm²) P j) number, type and wattage of lamp(s) P - declaration of mains connected windings N/A - declaration for SELV-equivalent controlgear N/A

8 (10) PROTECTION AGAINST ACCIDENTAL CONTACT WITH LIVE PARTS P - (10.1) Controlgear protected against accidental contact P with live parts - (A2) Voltage measured with 50 kΩ (see Annex A) P - (A3) Voltage > 35 V r.m.s. or > 60 V d.c. or protective (see Annex A) P impendance device - (10.1) Lacquer or enamel not used for protection or P insulation Adequate mechanical strength on parts providing P protection - (10.2) Capacitors > 0,5 μF: voltage after 1 min (V): Max. 8,4V P < 50 V ...... : - (10.3) Controlgear providing SELV N/A

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.: 00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 2 of 43 http://www.tuv-sud.cn P.R.China

Attachment 3 IEC 61347-2-13 Clause Requirement + Test Result - Remark Verdict

Accessible conductive parts are insulated from N/A live parts by double or reinforced insulation in SELV controlgear No connection between output circuit and the N/A body or protective earthing curcuit No possibility of connection between output circuit N/A and the body or protective earthing circuit through other conductive parts SELV outputs separated by at least basic N/A insulation ELV conductive parts insulated as live parts N/A Tests according Annex L of IEC 61347-1 N/A - (10.4) Accessible conductive parts in SELV circuits N/A Output voltage under load ≤ 25 V r.m.s. or ≤ 60 V N/A d.c. If output voltage > 25 V r.m.s. or > 60 V d.c.; N/A No load output ≤ 35 V peak or ≤ 60 V d.c and touch current does not exceed 0,7 mA (peak) or 2 mA d.c...... : One conductive part is insulated if output voltage N/A or current exceeding the values above and withstand test voltage 500 V Double or reinforced insulation bridged by N/A appropriate and at least two resistors or two Y2 capacitors or one Y1 capacitor Y1 or Y2 capacitors comply with IEC 60384-14 N/A Resistors comply with test (a) in 14.1 of N/A IEC 60065 8.1 SELV-equivalent controlgear accessible parts are N/A insulated from live parts by double or reinforced insulation according 8.6 and 13.1 in IEC 60065 8.2 Exposed terminals of SELV or SELV-equivalent N/A controlgear if: - the rated or maximum rated output voltages ≤ 25 V r.m.s. - the no-load output voltage ≤ 30 V r.m.s. or 33 √2 V peak Insulated terminals if convertor with rated output Input and output terminal P voltage > 25 V have insulation cover

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.: 00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 3 of 43 http://www.tuv-sud.cn P.R.China

Attachment 3 IEC 61347-2-13 Clause Requirement + Test Result - Remark Verdict

One capacitor Y1 or two capacitors Y2 complying N/A with IEC 60384-14 of the same values used in series between SELV or SELV-equivalent output and primary circuits Other components bridging the separating N/A transformer complying with IEC 60065, clause 14

9 (8) TERMINALS P Screw terminals according section 14 of IEC 60598-1: N/A Separately approved; component list (see Annex 1) P Part of the controlgear (see Annex 2) N/A Screwless terminals according section 15 of IEC 60598-1: N/A Separately approved; component list (see Annex 1) N/A Part of the controlgear (see Annex 3) N/A

10 (9) PROVISION FOR PROTECTIVE EARTHING N/A - (9.1) Provisions for protective earthing N/A Terminal complying with clause 8 N/A Locked against loosening and not possible to N/A loosen by hand Not possible to loosen clamping means N/A unintentionally on screwless terminals Earthing via means of fixing N/A Earthing terminal only used for the earthing of the N/A control gear All parts of material minimizing the danger of N/A electrolytic corrosion Made of brass or equivalent material N/A Contact surface bare metal N/A - (9.2) Provision for functional earthing N/A Comply with clause 8 and 9.1 N/A - (9.3) Earth contact via the track on the printed board N/A Test with a current of 25 A between earthing N/A terminal and each of the accessible metal parts; measured resistance (Ω) at ≥ 10 A according 7.2.3 of IEC 60598-1: < 0,5 Ω ...... : - (9.4) Earthing of built-in lamp controlgear N/A

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.: 00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 4 of 43 http://www.tuv-sud.cn P.R.China

Attachment 3 IEC 61347-2-13 Clause Requirement + Test Result - Remark Verdict

Earth by means of fixing to earthed metal of N/A luminaire in compliance of 7.2 of IEC 60598-1 Earthing terminal only for earthing the built-in N/A controlgear - (9.5) Earthing via independent controlgear N/A - (9.5.1) Earth connection to other equipment N/A Looping or through connection, conductor min. N/A 1,5 mm² and of copper or equivalent Protective earthing wires in line with 5.3.1.1 and N/A clause 7 - (9.5.2) Earthing of the lamp compartments powered via the independent lamp N/A controlgear Test with a current of 25 A between input and N/A output earth terminals; measured resistance (Ω) between earthing terminal and each of the accessible metal parts at ≥ 10 A according 7.2.3 of IEC 60598-1: < 0,5 Ω ...... : Output earthing terminal marked as in 7.1 t) of N/A IEC 61347-1

11 (11) MOISTURE RESISTANCE AND INSULATION P After storage 48 h at 91-95% relative humidity and 20-30 °C measuring of P insulation resistance with d.c. 500 V (MΩ): For basic insulation ≥ 2 MΩ ...... : >10 MΩ P For double or reinforced insulation ≥ 4 MΩ ...... : >10 MΩ P Between primary and secondary circuits in N/A controlgear providing SELV, values in Annex L in IEC 61347-1 11 (-) Adequate insulation between input and output N/A terminals not bounded together in SELV- equivalent controlgear

12 (12) ELECTRIC STRENGTH P Immediately after clause 11 electric strength test P for 1 min Basic insulation for SELV, test voltage 500 V N/A Working voltage ≤ 50 V, test voltage 500 V N/A Working voltage > 50 V ≤ 1000 V, test voltage (V): P

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.: 00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 5 of 43 http://www.tuv-sud.cn P.R.China

Attachment 3 IEC 61347-2-13 Clause Requirement + Test Result - Remark Verdict

Basic insulation, 2U + 1000 V 1480 V P Supplementary insulation, 2U + 1000 V N/A Double or reinforced insulation, 4U + 2000 V OP-DY220/40-150CC: P 3600V (400V Max.); OP-DY220/13.5-150CC and OP-DY220/8-150CC: 3400V (350V Max.); OP-DY220/7-150CC: 3400V (350V Max.) No flashover or breakdown P Solid or thin sheet insulation for double or N/A reinforced insulation fulfil the requirements in Annex N in IEC 61347-1 12 (-) Windings in separating transformers in SELV- N/A equivalent convertors according to 14.3.2 of IEC 60065

14 (14) FAULT CONDITIONS P - (14) When operated under fault conditions the controlgear: P - does not emit flames or molten material P - does not produce flammable gases P - protection against accidental contact not P impaired Thermally protected controlgear does not exceed N/A the marked temperature value Fault conditions: capacitors, resistors or inductors (see appended table) P without proof of compliance with relevant specifications have been short-circuited or disconnected - (14.1) Short-circuit of creepage distances and (see appended table) P clearances if less than specified in clause 16 in Part 1 (except between live parts and accessible metal parts) Creepage distances on printed boards less than P specified in clause 16 in Part 1 provided with coating according to IEC 60664-3 - (14.2) Short-circuit or interruption of semiconductor (see appended table) P devices - (14.3) Short-circuit across insulation consisting of (see appended table) N/A lacquer, enamel or textile - (14.4) Short-circuit across electrolytic capacitors (see appended table) P

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.: 00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 6 of 43 http://www.tuv-sud.cn P.R.China

Attachment 3 IEC 61347-2-13 Clause Requirement + Test Result - Remark Verdict

- (14.5) After the tests has been carried out on three samples: P The insulation resistance ≥ 1 MΩ ...... : >10 MΩ P No flammable gases P No accessible parts have become live P During the tests, a five-layer tissue paper, where P the test specimen is wrapped, does not ignite - (14.6) Relevant fault condition tests with high-power ⎯ supply 14 (-) Temperature declared thermally protected lamp N/A controlgear fulfil requirements in Annex C 15 (-) TRANSFORMER HEATING N/A Windings of separating transformer in a SELV- N/A equivalent controlgear fulfil the requirements according to 7.1 and 11.2 of IEC 60065 15.1 (-) Normal operation N/A Temperatures do not exceed the changed values N/A of the values in column 2 of Table 3 of IEC 60065, in respect to relevant ambient temperature at tc, under normal operation 15.2 (-) Abnormal operation N/A Temperatures do not exceed the changed values N/A of the values in column 3 of Table 3 of IEC 60065, in respect to relevant ambient temperature at tc, under abnormal conditions of Cl. 16 and fault conditions of Cl. 14

Ambient temperature at tc ...... : ⎯

16 (-) ABNORMAL CONDITIONS P 16.1 (-) Control gear which are of the constant voltage output type: N/A a) No LED module inserted N/A b) Double LED modules or equivalent load N/A connected to the output terminals c) Output terminal short-circuited (20 cm and 200 N/A cm or declared length) During and at the end of the tests no defect N/A impairing safety, nor any smoke or flammable gases produced 16.2 (-) Control gear which are of the constant current output type P

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.: 00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 7 of 43 http://www.tuv-sud.cn P.R.China

Attachment 3 IEC 61347-2-13 Clause Requirement + Test Result - Remark Verdict

a) No LED module connected P b) Double the LED modules or equivalent load P connected in series to the output terminals c) Output terminal short-circuited (20 cm and 200 P cm or declared length ) Maximum output voltage not exceeded P During and at the end of the tests no defect P impairing safety, nor any smoke or flammable gases produced

17 (15) CONSTRUCTION P - (15.1) Wood, cotton, silk, paper and similar fibrous material P Wood, cotton, silk, paper and similar fibrous P material not used as insulation - (15.2) Printed circuits P Printed circuits used as internal connections P complies with clause 14 - (15.3) Plugs and socket-outlets used in SELV or ELV circuits N/A No dangerous compatibility between output N/A socket-outlet and a plug for socket-outlets for input circuit in relation to installation rules, voltages and frequencies Plugs and socket-outlets for SELV comply with N/A IEC 60906-3 and IEC 60884-2-4 Plugs and socket-outlets for SELV ≤ 3 A, ≤ 25 V N/A r.m.s. or ≤ 60 V d.c. and ≤ 72 W comply with IEC 60906-3 and IEC 60884-2-4 or: - plugs not able to enter socket-outlets of other N/A standardised system - socket-outlets not admit plugs of other N/A standardised system - socket-outlets without protective earth N/A 17 (-) Socket-outlet in the output circuit does not accept N/A plugs complying with IEC 60083 and IEC 60906 Not possible to engage plugs accepted by socket- N/A outlet in the output circuit with socket-outlets complying with IEC 60083 and IEC 60906

18 (16) CREEPAGE DISTANCES AND CLEARANCES P

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.: 00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 8 of 43 http://www.tuv-sud.cn P.R.China

Attachment 3 IEC 61347-2-13 Clause Requirement + Test Result - Remark Verdict

- (16) Creepage distances and clearances according to (see appended table) P Table 3 and 4, as appropriate Controlgears providing SELV comply with L.1 in N/A Annex L Insulating lining of metallic enclosures N/A Basic insulation on printed boards tested N/A according to clause 14 Distances subjected to both sinusoidal voltage as N/A non-sinusoidal pulses not less than value in either Table 3 or 4 Creepage distances not less than minimum P clearance

19 (17) SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS P Screws, current-carrying parts and connections in compliance with IEC 60598-1 P (clause numbers between parentheses refer to IEC 60598-1) (4.11) Electrical connections P (4.11.1) Contact pressure N/A (4.11.2) Screws: N/A - self-tapping screws N/A - thread-cutting screws N/A (4.11.3) Screw locking: N/A - spring washer N/A - rivets N/A (4.11.4) Material of current-carrying parts P (4.11.5) No contact to wood or mounting surface P (4.11.6) Electro-mechanical contact systems N/A (4.12) Mechanical connections and glands P (4.12.1) Screws not made of soft metal P Screws of insulating material N/A Torque test: torque (Nm); part ...... : 0,5Nm, Ф2,93mm, Screw P fixing terminal cover Torque test: torque (Nm); part ...... : N/A Torque test: torque (Nm); part ...... : N/A (4.12.2) Screws with diameter < 3 mm screwed into metal N/A (4.12.4) Locked connections: N/A

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.: 00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 9 of 43 http://www.tuv-sud.cn P.R.China

Attachment 3 IEC 61347-2-13 Clause Requirement + Test Result - Remark Verdict

- fixed arms; torque (Nm) ...... : N/A - lampholder; torque (Nm)...... : N/A - push-button switches; torque 0,8 Nm ...... : N/A (4.12.5) Screwed glands; force (Nm) ...... : N/A

20 (18) RESISTANCE TO HEAT, FIRE AND TRACKING P - (18.1) Ball-pressure test: P - part tested; temperature (°C) ...... : Enclosure, 125°C, Ф1,2mm P - part tested; temperature (°C) ...... : PCB, 125°C, Ф0,8mm P - part tested; temperature (°C) ...... : Bobbin of Transformer 125°C, P Ф1,1mm - (18.2) Test of printed boards: P - part tested ...... : PCB P - part tested ...... : N/A - (18.3) Glow-wire test (650°C): P - part tested ...... : Enclosure P - part tested ...... : N/A - (18.4) Needle flame test (10 s): P - part tested ...... : PCB P - part tested ...... : Bobbin of transformer P - (18.5) Tracking test: N/A - part tested ...... : N/A - part tested ...... : N/A

21 (19) RESISTANCE TO CORROSION N/A - test according 4.18.1 of IEC 60598-1 N/A - adequate varnish on the outer surface N/A

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.: 00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 10 of 43 http://www.tuv-sud.cn P.R.China

Attachment 3 IEC 61347-2-13 Clause Requirement + Test Result - Remark Verdict

14 TABLE: tests of fault conditions (Model OP-DY220/40-150CC) P Part Simulated fault Hazard Output S/C: unit shut down, no output, recoverable NO D1 S/C: unit shut down, no output, recoverable NO D2 S/C: fuse opened fast NO D6 S/C: unit shut down, no output, recoverable NO D7 S/C: fuse opened fast NO C1 S/C: unit shut down, no output, recoverable; NO O/C: work as normal C3 S/C: fuse opened fast; NO O/C: R6 and R7 opened fast, shut down, no output C10 S/C, O/C: unit shut down, no output, recoverable NO C14 S/C: unit shut down, no output, recoverable NO O/C: work as normal Q1 S/C: fuse opened fast NO Q2 S/C: fuse opened fast NO Supplementary information: SC is the abbreviation of short-circuited; OC is the abbreviation of open-circuit.

14 TABLE: tests of fault conditions P (Model OP-DY220/13.5-150CC and OP-DY220/8-150CC) Part Simulated fault Hazard Output S/C: unit shut down, no output, recoverable NO BD1 S/C: fuse opened fast NO D1 S/C: work as normal NO D2 S/C: EC2 broken fast, no output NO D4 S/C: unit shut down, no output, recoverable NO D5 S/C: unit shut down, no output, recoverable NO EC1 S/C: EC2 broken fast, no output; NO O/C: EC2 broken fast, no output EC2 S/C: EC1 broken fast, no output; NO O/C: EC1 broken fast, no output. EC3 S/C, O/C: unit shut down, no output, recoverable NO EC4 S/C: unit shut down, no output, recoverable NO O/C: work as normal Q1 S/C: fuse opened fast NO

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.: 00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 11 of 43 http://www.tuv-sud.cn P.R.China

Attachment 3 IEC 61347-2-13 Clause Requirement + Test Result - Remark Verdict

Supplementary information: SC is the abbreviation of short-circuited; OC is the abbreviation of open-circuit.

14 TABLE: tests of fault conditions (Model OP-DY220/7-150CC) P Part Simulated fault Hazard Output S/C: unit shut down, no output, recoverable NO C5 O/C: work as normal NO S/C: Fuse R1 was operated. C2 NO O/C: work as normal S/C: Fuse R1 was operated. C3 NO O/C: work as normal D1 S/C: Fuse R1 was operated. NO D5 S/C: work as normal NO D6 S/C: work as normal NO D7 S/C: work as normal NO D8 S/C: unit shut down, no output, recoverable NO D10 S/C: unit shut down, no output, recoverable NO Q1 S/C: unit shut down NO Supplementary information: SC is the abbreviation of short-circuited; OC is the abbreviation of open-circuit.

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.: 00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 12 of 43 http://www.tuv-sud.cn P.R.China

Attachment 3 IEC 61347-2-13 Clause Requirement + Test Result - Remark Verdict

18 (16) TABLES: Creepage distances and clearances (Model OP-DY220/40-150CC) P Table 3 Minimum distances (mm) for a.c. (50/60 Hz) sinusoidal voltages P RMS working voltage (V) not exceeding 50 150 250 500 750 1000 Creepage distances Required basic insulation, PTI ≥ 600 0,6 0,8 1,5 3 4 5,5 Measured ------Required basic insulation, PTI < 600 1,2 1,6 2,5 5 8 10 Measured -- -- 2,6 ------Required supplementary insulation PTI ≥ 600 - 0,8 1,5 3 4 5,5 Measured ------Required supplementary insulation PTI < 600 - 1,6 2,5 5 8 10 Measured ------Required reinforced insulation - 3,2 5 6 8 11 Measured ------10,5 -- -- Clearances Required basic insulation 0,2 0,8 1,5 3 4 5,5 Measured -- -- 2,6 ------Required supplementary insulation - 0,8 1,5 3 4 5,5 Measured ------Required reinforced insulation - 1,6 3 6 8 11 Measured ------10,5 -- -- Table 4 Minimum distances (mm) for non-sinusoidal pulse voltages N/A Rated pulse voltage (peak kV) 2,0 2,5 3,0 4,0 5,0 6,0 8,0 Required clearances 1,0 1,5 2 3 4 5,5 8 Measured Rated pulse voltage (peak kV) 10 12 15 20 25 30 40 Required clearances 11 14 18 25 33 40 60 Measured Rated pulse voltage (peak kV) 50 60 80 100 - - - Required clearances 75 90 130 170 - - - Measured

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.: 00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 13 of 43 http://www.tuv-sud.cn P.R.China

Attachment 3 IEC 61347-2-13 Clause Requirement + Test Result - Remark Verdict

18 (16) TABLES: Creepage distances and clearances P (Model OP-DY220/13.5-150CC, OP-DY220/8-150CC and OP-DY220/7-150CC) Table 3 Minimum distances (mm) for a.c. (50/60 Hz) sinusoidal voltages P RMS working voltage (V) not exceeding 50 150 250 500 750 1000 Creepage distances Required basic insulation, PTI ≥ 600 0,6 0,8 1,5 3 4 5,5 Measured ------Required basic insulation, PTI < 600 1,2 1,6 2,5 5 8 10 Measured -- -- 2,97 ------Required supplementary insulation PTI ≥ 600 - 0,8 1,5 3 4 5,5 Measured ------Required supplementary insulation PTI < 600 - 1,6 2,5 5 8 10 Measured ------Required reinforced insulation - 3,2 5 6 8 11 Measured ------8,3 -- -- Clearances Required basic insulation 0,2 0,8 1,5 3 4 5,5 Measured -- -- 1,95 ------Required supplementary insulation - 0,8 1,5 3 4 5,5 Measured ------Required reinforced insulation - 1,6 3 6 8 11 Measured ------8,3 -- -- Table 4 Minimum distances (mm) for non-sinusoidal pulse voltages N/A Rated pulse voltage (peak kV) 2,0 2,5 3,0 4,0 5,0 6,0 8,0 Required clearances 1,0 1,5 2 3 4 5,5 8 Measured Rated pulse voltage (peak kV) 10 12 15 20 25 30 40 Required clearances 11 14 18 25 33 40 60 Measured Rated pulse voltage (peak kV) 50 60 80 100 - - - Required clearances 75 90 130 170 - - -

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.: 00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 14 of 43 http://www.tuv-sud.cn P.R.China

Attachment 3 IEC 61347-2-13 Clause Requirement + Test Result - Remark Verdict

Measured

A ANNEX A - TEST TO ESTABLISH WHETHER A CONDUCTIVE PART IS A P LIVE PART WHICH MAY CAUSE AN ELECTRIC SHOCK A.1 Comply with A.2 or A.3 P A.2 Voltage ≤ 35 V peak or ≤ 60 V d.c ...... : N/A A.3 If voltage > 35 V r.m.s. or > 60 V d.c. or protective 0,04mA P impendance device; touch current does not exceed 0,7 mA (peak) or 2 mA d.c...... : Comply with Annex G of IEC 60598-1 P

C ANNEX C – PARTICULAR REQUIREMENTS FOR ELECTRONIC LAMP N/A CONTROLGEAR WITH MEANS OF PROTECTION AGAINST OVERHEATING C3 GENERAL REQUIREMENTS N/A C3.1 Thermal protection means integral with the N/A convertor, protected against mechanical damage Renewable only by means of a tool N/A If function depending on polarity, for cord- N/A connected equipment protection means in both leads Thermal links comply with IEC 60691 N/A Electrical controls comply with IEC 60730-2-3 N/A C3.2 No risk of fire by breaking (clause C7) N/A C5 CLASSIFICATION N/A a) automatic resetting type ⎯ b) manual resetting type ⎯ c) non-renewable, non-resetting type ⎯ d) renewable, non-resetting type ⎯ e) other type of thermal protection; description .. : N/A C6 MARKING N/A C6.1 Symbol for temperature declared thermally N/A protected ballasts C6.2 Declaration of the type of protection provided N/A C7 LIMITATION OF HEATING N/A

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.: 00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 15 of 43 http://www.tuv-sud.cn P.R.China

Attachment 3 IEC 61347-2-13 Clause Requirement + Test Result - Remark Verdict

C7.1 Preselection test: N/A Test sample placed for at least 12 h in an oven N/A having temperature (tc - 5) K No operation of the protection device N/A C7.2 Functioning of protection means: N/A Normal operation of the sample in a test N/A enclosure according to Annex D at an ambient

temperature such that (tc +0; -5) °C is obtained No operation of the protection device N/A Introducing of the most onerous test condition N/A determined during test of clause 14 Output of windings connected to the mains supply N/A short-circuited, and other part of the convertor operated under normal conditions Increasing of the current through the windings N/A continuously until operation of the protection means Continuous measuring of the highest surface N/A temperature Ballasts according to C5 a) or C5 e) operated N/A until stable conditions are achieved Automatic-resetting thermal protectors working N/A 3 times Ballasts according to C5 b) working 6 times N/A Ballasts according to C5 c) and C5) d) working N/A once Highest temperature does not exceed the marked N/A value Any overshoot of 10% over the marked value N/A within 15 min

D ANNEX D – REQUIREMENTS FOR CARRY OUT THE HEATING TESTS OF N/A THERMALLY PROTECTED LAMP CONTROLGEAR Tests in C7 performed in accordance with Annex N/A D, if applicable

E ANNEX E – USE OF CONSTANT S OTHER THAN 4500 IN tw TESTS N/A Comply with tests according Annex E N/A

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.: 00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 16 of 43 http://www.tuv-sud.cn P.R.China

Attachment 3 IEC 61347-2-13 Clause Requirement + Test Result - Remark Verdict

F ANNEX F - DRAUGHT-PROOF ENCLOSURE P Draught-proof enclosure in accordance with the P description Dimensions of the enclosure P Other design; description N/A

H ANNEX H - TESTS P All tests performed in accordance with the advice P given in Annex H, if applicable

I ANNEX I: PARTICULAR ADDITIONAL REQUIREMENTS FOR INDEPENDENT N/A SELV D.C. OR A.C. SUPPLIED ELECTRONIC CONTROLGEAR FOR LED MODULES I.3 Classification N/A I.3.1 Class I Yes No ⎯ Class II Yes No ⎯ I.3.2 a) non-inherently short circuit proof controlgear Yes No ⎯ b) non-inherently open circuit proof controlgear Yes No ⎯ c) inherently short circuit proof controlgear Yes No ⎯ d) inherently open circuit proof controlgear Yes No ⎯ e) fail safe controlgear Yes No ⎯ f) non-short-circuit proof controlgear Yes No ⎯ g) non-open-circuit proof controlgear Yes No ⎯ I.4 Marking N/A Adequate symbols are used N/A I.5 Protection against electric shock N/A I.5.1 No connection between output winding and body N/A No connection between output winding and N/A protective earthing circuit I.5.2 Input and output circuits electrically separated N/A from each other I.5.2.1 Insulation between input and output winding of N/A the HF-transformer consists of double or reinforced insulation Class II: insulation between input/output and N/A body consists of double or reinforced insulation

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.: 00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 17 of 43 http://www.tuv-sud.cn P.R.China

Attachment 3 IEC 61347-2-13 Clause Requirement + Test Result - Remark Verdict

Class I: insulation between input and body N/A consists of basic and between output and body supplementary insulation I.5.2.2 Insulation between input and output winding via N/A the core consists of double or reinforced insulation Insulation between cord and windings of the HD- N/A transformer consists of basic insulation I.5.2.3 Serrated tape, additional layer N/A I.5.2.4 Class I controlgear for fixed connection provided N/A with basic insulation plus protective screening comply with the following conditions: a) Insulation between the input winding and the N/A protective screen complies with the requirements for basic insulation b) Insulation between the protective screen and N/A the output winding complies with the requirements for basic insulation c)Metal screen consists of a metal foil or of a wire N/A d) Metal screen so arranged that both edges N/A cannot simultaneously touch a magnetic core e) Metal screen and its lead-out wire have a N/A cross-section sufficient to ensure that an overload device will open the circuit before the screen is destroyed f) Lead-out wire sufficiently fixed to the metal N/A screen I.5.2.5 Last turn of each winding of the transformer N/A retained by positive means Impregnated winding N/A Winding held together by means of insulating N/A material I.5.3 Components bridging between input and output N/A circuit I.5.3.1 Used capacitors and resistors comply with 8.2 N/A I.5.3.2 Used opto-couplers comply with 2.10.5.2 of IEC N/A 60950-1 or 0,4 mm and test in I.8 I.6 Heating N/A I.6.1 No excessive temperatures in normal use N/A Used material classified as Class ...... : ⎯

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.: 00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 18 of 43 http://www.tuv-sud.cn P.R.China

Attachment 3 IEC 61347-2-13 Clause Requirement + Test Result - Remark Verdict

Stated value of ta ...... : ⎯ I.6.2 Temperature rises (Upri: 1.06 time supply rated voltage) N/A Determined temperature rises in windings: N/A - Primary (K) ...... : - Limit max (K) ...... : - Secondary (K) ...... : - Limit max (K) ...... : After the test: N/A - no connections have worked loose N/A - no reduction of creepage distances and N/A clearances - no flow of sealing compound N/A - no operation of protecting devices N/A - electric strength test between input and output N/A windings I.6.3 Cycling test (10 cycles): N/A I.6.3.1 - heat run at (K) ...... : N/A I.6.3.2 - moisture treatment 48 h N/A I.6.3.3 - vibration test 1 h; 1,5 g N/A I.6.3.4 After the tests: N/A - insulation resistance ≥ 2, 4 or 5 MΩ N/A - dielectric strength test for 2 min. at 35 % of N/A specified value in table I.6 - Current or the ohmic component does not N/A deviates by more than 30 % I.7 Short-circuit and overload protection N/A I.7.1 Upri: 1.06 times rated voltage or 0.94 and 1.06 N/A times rated supply voltage (V) ...... : I.7.2 Determined temperature rise in windings and on other parts: N/A I.7.3 I.7.4 - test according to Clause ...... : N/A - Primary winding (K) ...... : N/A - Limit max (K) ...... : N/A - Secondary winding (K) ...... : N/A - Limit max (K) ...... : N/A

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.: 00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 19 of 43 http://www.tuv-sud.cn P.R.China

Attachment 3 IEC 61347-2-13 Clause Requirement + Test Result - Remark Verdict

- External enclosure < 80 (K) ...... : N/A - Rubber insulation of wiring < 60 (K) ...... : N/A - PVC insulation of wiring < 60 (K) ...... : N/A - Supports < 80 (K) ...... : N/A I.7.5 Fail-safe convertors N/A I.7.5.1 - Upri: 1.06 times rated supply voltage ...... V: ⎯ - Isec: 1.5 times rated output current ...... A: ⎯ - time until steady-state conditions t1 (h) ...... : ⎯ - time until failure t2 (h): < t1; < 5 h ...... : N/A I.7.5.2 During the test: N/A - no flames, molten material, etc. N/A - temperature rise of enclosure < 150 K N/A - temperature rise of plywood support < 100 K N/A After the test: N/A - electric strength (test voltage; 35 % of specified N/A value); no flashover or breakdown for primary-to- secondary and for primary-to-body - live parts not accessible by test finger through N/A holes of enclosure I.8 Insulation resistance and electric strength N/A I.8.1 Conditioned 48 h between 91 % and 95 % N/A I.8.2 Adequate insulation (500 V d.c. for 1 min) between: N/A Live parts and the body -for basic insulation not N/A less than 2 MΩ ...... : Live parts and the body -for reinforced insulation N/A not less than 4 MΩ ...... : Input- and output circuits not less than 5 MΩ ...... : N/A Metal parts of class II convertors which are N/A separated from live parts by basic insulation only and the body not less than 5 MΩ ...... : Metal foil in contact with the inner and outer N/A surfaces of enclosures of insulating material not less than 2 MΩ ...... : I.8.3 Electric strength test: N/A 1) Between live parts of input circuits and live N/A parts of output circuits ...... :

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.: 00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 20 of 43 http://www.tuv-sud.cn P.R.China

Attachment 3 IEC 61347-2-13 Clause Requirement + Test Result - Remark Verdict

2) Over basic or supplementary insulation between: N/A a) live parts which are or may become of N/A different polarity ...... : b) live parts and body if intended to be connected N/A to protective earth ...... : c) accessible metal parts and a metal rod of the N/A same diameter as the flexible cable or cord ...... : d) live parts and an intermediate metal part ...... : N/A e) intermediate metal parts and the body ...... : N/A 3) Over reinforced insulation between the body N/A and live parts ...... : No flashover or breakdown occurred N/A I.9 Construction N/A I.9.1 Comply with all requirements N/A I.9.2 The distance between input and output terminals N/A shall not be less than 25 mm ...... : I.10 Components N/A I.10.1 Socket-outlets in the output circuit does not N/A accept plugs complying with IEC 60083 and IEC 60906-1 I.10.2 Self-resetting protective devices shall not be N/A used unless it is certain that there will be no hazards Compliance is checked by connecting the N/A convertor for 48 h at 1.06 times the rated voltage with the output short-circuited I.11 Creepage distances and clearances N/A 1. Insulation between input and output circuits: N/A a) measured values > specified values (mm) ...... : N/A b) measured values > specified values (mm) ...... : N/A c) measured values > specified values (mm) ...... : N/A 2. Insulation between adjacent input circuits: N/A measured values > specified values (mm) ...... : 2. Insulation between adjacent output circuits: N/A measured values > specified values (mm) ...... : 3. Insulation between terminals for external connection: N/A a) measured values > specified values (mm) ...... : N/A b) measured values > specified values (mm) ...... : N/A

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.: 00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 21 of 43 http://www.tuv-sud.cn P.R.China

Attachment 3 IEC 61347-2-13 Clause Requirement + Test Result - Remark Verdict

c) measured values > specified values (mm) ...... : N/A 4. Basic or supplementary insulation: N/A a) measured values > specified values (mm) ...... : N/A b) measured values > specified values (mm) ...... : N/A c) measured values > specified values (mm) ...... : N/A d) measured values > specified values (mm) ...... : N/A e) measured values > specified values (mm) ...... : N/A 5. Reinforced insulation: measured values > N/A specified values (mm) ...... : 6. Distance through insulation: N/A a) measured values > specified values (mm) ...... : N/A b) measured values > specified values (mm) ...... : N/A c) measured values > specified values (mm) ...... : N/A d) measured values > specified values (mm) ...... : N/A

L ANNEX L: PARTICULAR ADDITIONAL REQUIREMENTS FOR N/A CONTROLGEARS PROVIDING SELV (IEC 61347-1) L.3 Classification N/A Class I Yes No ⎯ Class II Yes No ⎯ Class III Yes No ⎯ non-inherently short circuit proof controlgear Yes No ⎯ inherently short circuit proof controlgear Yes No ⎯ fail safe controlgear Yes No ⎯ non-short-circuit proof controlgear Yes No ⎯ L.4 Marking N/A Adequate symbols are used N/A L.5 Protection against electric shock N/A Comply with 9.2 of IEC 61558-1 N/A L.6 Heating N/A No excessive temperatures in normal use N/A

Value if capacitor tc marked ...... : ⎯ Winding insulation classified as Class ...... : ⎯

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.: 00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 22 of 43 http://www.tuv-sud.cn P.R.China

Attachment 3 IEC 61347-2-13 Clause Requirement + Test Result - Remark Verdict

Comply with tests of clause 14 of IEC 61558-1 N/A with adjustments L.7 Short-circuit and overload protection N/A Comply with tests of clause 15 of IEC 61558-1 N/A with adjustments L.8 Insulation resistance and electric strength N/A L.8.1 Conditioned 48 h between 91 % and 95 % N/A L.8.2 Insulation resistance N/A Between input- and output circuits not less than 5 N/A MΩ ...... : Between metal parts of class II convertors which N/A are separated from live parts by basic insulation only and the body not less than 5 MΩ ...... : Between metal foil in contact with the inner and N/A outer surfaces of enclosures of insulating material not less than 2 MΩ ...... : L.8.3 Electric strength N/A 1) Between live parts of input circuits and live N/A parts of output circuits ...... : 2) Over basic or supplementary insulation between: N/A a) live parts having different polarity ...... : N/A b) live parts and body if intended to be connected N/A to protective earth ...... : c) accessible metal parts and a metal rod of the N/A same diameter as the flexible cable or cord ...... : d) live parts and an intermediate metal part ...... : N/A e) intermediate metal parts and the body ...... : N/A f) each input circuit and all other input circuits ... : N/A 3) Over reinforced insulation between the body N/A and live parts ...... : L.9 Construction N/A L.9.1 Transformer comply with 19.12 of IEC 61558-1 N/A and 19 of IEC 61558-2-6 HF transformer comply with 19 of IEC 61558-2-16 N/A L.10 Components N/A Protective devices comply with 20.6 – 20.11 of N/A IEC 61558-1

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.: 00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 23 of 43 http://www.tuv-sud.cn P.R.China

Attachment 3 IEC 61347-2-13 Clause Requirement + Test Result - Remark Verdict

L.11 Creepage distances and clearances N/A 1. Insulation between input and output circuits, basic insulation: N/A a) measured values > specified values (mm) ..... : N/A b) measured values > specified values (mm) ..... : N/A c) measured values > specified values (mm) ..... : N/A 2. Insulation between input and output circuits, double or reinforced insulation: N/A a) measured values > specified values (mm) ..... : N/A b) measured values > specified values (mm) ..... : N/A c) measured values > specified values (mm) ..... : N/A 3. Insulation between adjacent input circuits N/A - measured values > specified values (mm) ...... : N/A 3. Insulation between adjacent output circuits N/A - measured values > specified values (mm) ...... : N/A 4. Insulation between terminals for external connection: N/A - measured values > specified values (mm) ...... : N/A 5. Basic or supplementary insulation: N/A a) measured values > specified values (mm) ..... : N/A b) measured values > specified values (mm) ..... : N/A c) measured values > specified values (mm) ..... : N/A d) measured values > specified values (mm) ..... : N/A e) measured values > specified values (mm) ..... : N/A 6. Reinforced insulation or insulation: N/A Between body and output circuit: measured N/A values > specified values (mm) ...... : Between body and output circuit if provision N/A against transient voltages: measured values > specified values (mm) ...... : 7. Distance through insulation: N/A a) measured values > specified values (mm) ..... : N/A b) measured values > specified values (mm) ..... : N/A c) measured values > specified values (mm) ..... : N/A

N ANNEX N: REQUIREMENTS FOR INSULATION MATERIALS USED FOR N/A DOUBLE OR REINFORCED INSULATION (IEC 61347-1)

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.: 00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 24 of 43 http://www.tuv-sud.cn P.R.China

Attachment 3 IEC 61347-2-13 Clause Requirement + Test Result - Remark Verdict

N.4 General requirements N/A N.4.1 Material comply with IEC 60085 and IEC 60216 Double insulation by envelop N/A series of power supply. N.4.2 Solid insulation N/A Electric strength test at least 5 kV or 1,35 x test N/A voltage in Table N.1 If not classified according IEC 60085 and IEC N/A 60216 series: Electric strength test increased 10 % of 5,5 kV or 1,5 x test voltage in Table N.1 N.4.3 Thin sheet insulation N/A N.4.3.1 Thickness and composition of thin sheet insulation N/A - Inside the ballast and not subjected to handling N/A or abrasion during the production and during maintenance - Non-separated layers: Min. 3 layers and fulfil N/A mandrel test of 150N - Separated layers: Min. 2 layers and each layer N/A fulfil mandrel test of 50N - Separated layers (alternative): Min. 3 layers and N/A 2/3 of the layers fulfil mandrel test of 100N N.4.3.2 Mandrel test (electric strength test during mechanical stress) N/A Electric strength test after mandrel test: N/A - Non-separated layers: min. 5 kV or 1,35 x test N/A voltage in Table N.1 - 2/3 of min. 3 separated layers: min. 5 kV or 1,25 N/A x test voltage in Table N.1 - one of 2 separated layers: min. 5 kV or 1,25 x N/A test voltage in Table N.1 No flashover or breakdown occurred N/A

O ANNEX O: ADDITIONAL REQUIREMENTS FOR BUILT-IN ELECTRONIC N/A CONTROLGEAR WITH DOUBLE OR REINFORCED INSULATION (IEC 61347-1) O.6 Marking N/A Marking according clause 7 (7) See clause 7 N/A Special symbol N/A Meaning of the special symbol explained in N/A catalogue O.7 Protection against accidental contact with live parts N/A

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.: 00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 25 of 43 http://www.tuv-sud.cn P.R.China

Attachment 3 IEC 61347-2-13 Clause Requirement + Test Result - Remark Verdict

Requirements of clause 8 (10) See clause 8 N/A Test finger not possible to make contact with N/A basic insulated metal parts O.8 Terminals N/A Clause 9 (8) See clause 9 N/A O.9 Provision for earthing N/A Functional earthing terminals comply with clause N/A 9 of part 1 No protective earthing terminal N/A O.10 Moisture resistance and insulation N/A Clause 11 (11) See clause 11 N/A O.11 Electric strength N/A Clause 12 (12) See clause 12 N/A O.13 Fault conditions N/A Clause 14 (14) See clause 14 N/A End of test, between live part and accessible N/A metal parts or external parts of insulating material in contact with the supporting surface comply with dielectric strength test reduced to 35 % of values according Table 1 in part 1 Insulation resistance according to O.10 between N/A live part and accessible metal parts or external parts of insulating material in contact with the supporting surface not less than 4 MΩ O.14 Construction N/A Clause 17 (15) See clause 17 N/A Accessible metal parts insulated from live parts N/A by double or reinforced insulation Live part insulated from supporting surface in N/A contact with external faces by double or reinforced insulation O.15 Creepage distances and clearances N/A Clause 18 (16) See clause 18 N/A Comply with corresponding values for luminaries N/A in IEC 60598-1 O.16 Screws, current-carrying parts and connections N/A Clause 19 (17) See clause 19 N/A O.17 Resistance to heat and fire N/A

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.: 00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 26 of 43 http://www.tuv-sud.cn P.R.China

Attachment 3 IEC 61347-2-13 Clause Requirement + Test Result - Remark Verdict

Clause 20 (18) See clause 20 N/A O.18 Resistance to corrosion N/A Clause 21 (19) See clause 21 N/A

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.: 00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 27 of 43 http://www.tuv-sud.cn P.R.China

Attachment 3 IEC 61347-2-13 Clause Requirement + Test Result - Remark Verdict

ANNEX 2: screw terminals (part of the luminaire) N/A

(14) SCREW TERMINALS N/A (14.2) Type of terminal ...... : ⎯ Rated current (A) ...... : ⎯ (14.3.2.1) One or more conductors N/A (14.3.2.2) Special preparation N/A (14.3.2.3) Terminal size N/A Cross-sectional area (mm²) ...... : N/A (14.3.3) Conductor space (mm) ...... : N/A (14.4) Mechanical tests N/A (14.4.1) Minimum distance N/A (14.4.2) Cannot slip out N/A (14.4.3) Special preparation N/A (14.4.4) Nominal diameter of thread (metric ISO thread) . : M N/A External wiring N/A No soft metal N/A (14.4.5) Corrosion N/A (14.4.6) Nominal diameter of thread (mm) ...... : N/A Torque (Nm) ...... : N/A (14.4.7) Between metal surfaces N/A Lug terminal N/A Mantle terminal N/A Pull test; pull (N) ...... : N/A (14.4.8) Without undue damage N/A

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.: 00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 28 of 43 http://www.tuv-sud.cn P.R.China

Attachment 3 IEC 61347-2-13 Clause Requirement + Test Result - Remark Verdict

ANNEX 3: screwless terminals (part of the luminaire) N/A

(15) SCREWLESS TERMINALS N/A (15.2) Type of terminal ...... : ⎯ Rated current (A) ...... : ⎯ (15.3.1) Material N/A (15.3.2) Clamping N/A (15.3.3) Stop N/A (15.3.4) Unprepared conductors N/A (15.3.5) Pressure on insulating material N/A (15.3.6) Clear connection method N/A (15.3.7) Clamping independently N/A (15.3.8) Fixed in position N/A (15.3.10) Conductor size N/A Type of conductor N/A (15.5) Terminals and connections for internal wiring N/A (15.5.1) Mechanical tests N/A (15.5.1.1.1) Pull test spring-type terminals (4 N, N/A 4 samples)….: (15.5.1.1.2) Pull test pin or tab terminals (4 N, N/A 4 samples)……: Insertion force not exceeding 50 N N/A (15.5.1.2) Permanent connections: pull-off test (20 N) N/A (15.6) Electrical tests N/A Voltage drop (mV) after 1 h (4 samples) ...... : N/A Voltage drop of two inseparable joints N/A Number of cycles ...... : ⎯ Voltage drop (mV) after 10th alt. 25th cycle N/A (4 samples) ...... : Voltage drop (mV) after 50th alt. 100th cycle N/A (4 samples) ...... : After ageing, voltage drop (mV) after 10th alt. N/A 25th cycle (4 samples) ...... :

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.: 00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 29 of 43 http://www.tuv-sud.cn P.R.China

Attachment 3 IEC 61347-2-13 Clause Requirement + Test Result - Remark Verdict

After ageing, voltage drop (mV) after 50th alt. N/A 100th cycle (4 samples) ...... : (15.7) Terminals external wiring N/A Terminal size and rating N/A (15.8.1) Pull test spring-type terminals or welded N/A connections (4 samples); pull (N) ...... : Pull test pin or tab terminals (4 samples); N/A pull (N) ...... : (15.9) Contact resistance test N/A Voltage drop (mV) after 1 h N/A terminal 1 2 3 4 5 6 7 8 9 10 voltage drop (mV) Voltage drop of two inseparable joints N/A Voltage drop after 10th alt. 25th cycle N/A Max. allowed voltage drop (mV) ...... : ⎯ terminal 1 2 3 4 5 6 7 8 9 10 voltage drop (mV) Voltage drop after 50th alt. 100th cycle N/A Max. allowed voltage drop (mV) ...... : ⎯ terminal 1 2 3 4 5 6 7 8 9 10 voltage drop (mV) Continued ageing: voltage drop after 10th alt. 25th cycle N/A Max. allowed voltage drop (mV) ...... : ⎯ terminal 1 2 3 4 5 6 7 8 9 10 voltage drop (mV) Continued ageing: voltage drop after 50th alt. 100th cycle N/A Max. allowed voltage drop (mV) ...... : ⎯ terminal 1 2 3 4 5 6 7 8 9 10 voltage drop (mV)

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.: 00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 30 of 43 http://www.tuv-sud.cn P.R.China

Attachment 3 IEC 61347-2-13 Clause Requirement + Test Result - Remark Verdict

Attachment 1: Test according to IEC/EN 60598-1 P

4.6 Impact tests: P (4.13.1) - fragile parts; energy (Nm) : No fragile parts N/A - other parts; energy (Nm) : Enclosure; 0,5 Nm P 1) live parts P 2) linings N/A 3) protection P 4) covers P (4.13.3) Straight test finger 30N P

4.10 (5.2) Supply connection and external wiring P 4.10 Means of connection……………………………...: Terminal block P (5.2.1) 4.10 Type of cable………………………………………: N/A (5.2.2) Nominal cross-sectional area (mm²)…………... : N/A Cables equal to IEC 60227 or IEC 60245 N/A 4.10 Type of attachment, X, Y or Z N/A (5.2.3) 4.10 Type Z not connected to screws N/A (5.2.5) 4.10 Cable entries: P (5.2.6) - suitable for introduction P - adequate degree of protection P 4.10 Cable entries through rigid material have rounded P (5.2.7) edges 4.10 Insulating bushings: N/A (5.2.8) - suitably fixed N/A - material in bushings N/A - material not likely to deteriorate N/A - tubes or guards made of insulating material N/A

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.: 00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 31 of 43 http://www.tuv-sud.cn P.R.China

Attachment 3 IEC 61347-2-13 Clause Requirement + Test Result - Remark Verdict

4.10 Locking of screwed bushings N/A (5.2.9) 4.10 Cord anchorage: P (5.2.10) - covering protected from abrasion P - clear how to be effective P - no mechanical or thermal stress P - no tying of cables into knots etc. P - insulating material or lining N/A 4.10 Cord anchorage for type X attachment: N/A (5.2.10.1) a) at least one part fixed N/A b) types of cable N/A c) no damaging of the cable N/A d) whole cable can be mounted N/A e) no touching of clamping screws N/A f) metal screw not directly on cable N/A g) replacement without special tool N/A Glands not used as anchorage N/A Labyrinth type anchorages N/A 4.10 Adequate cord anchorage for type Y and type Z N/A (5.2.10.2) attachment 4.10 Tests: P (5.2.10.3) - impossible to push cable; unsafe P - pull test: 25 times; pull (N) : 60 P - torque test: torque (Nm) : 0,15 P - displacement ≤ 2 mm 0,6mm P - no movement of conductors P - no damage of cable or cord P 4.10 External wiring passing into luminaire N/A (5.2.11) 4.10 Looping-in terminals N/A (5.2.12) 4.10 Wire ends not tinned N/A (5.2.13)

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.: 00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 32 of 43 http://www.tuv-sud.cn P.R.China

Attachment 3 IEC 61347-2-13 Clause Requirement + Test Result - Remark Verdict

Wire ends tinned: no cold flow N/A 4.10 Mains plug same protection N/A (5.2.14) Class III luminaire plug N/A 4.10 Appliance inlets (IEC 60320) N/A (5.2.16) Appliance couplers of class II type N/A 4.10 No standardized interconnecting cables properly N/A (5.2.17) assembled 4.10 Used plug in accordance with N/A (5.2.18) - IEC 60083 N/A - other standard N/A

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.: 00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 33 of 43 http://www.tuv-sud.cn P.R.China

Attachment 3 IEC 61347-2-13 Clause Requirement + Test Result - Remark Verdict

Attachment 2: Heating test according to clause 16 of IEC/EN 61347-2-13 and 12.4 of IEC/EN 60598-1 P

Type reference ...... : OP-DY220/40-150CC ⎯ Load used ...... : Equivalent resistance load ⎯ Mounting position ...... : On black plywood (according ⎯ to H.12.2 in Annex H) ta ...... : 50 °C ⎯ - rated voltage ...... : 220-240 V ⎯ - test voltage (normal operation) ...... : Input: 254,4 V, 0,18 A; 42,1W; ⎯ - test voltage (abnormal operation) ...... : 1. No lamp is inserted ⎯ 264 V; 0,01 A; 1,1 W 2. Double the LED modules or equivalent load 264 V; 0,18 A; 34,0 W 3. The output shall be short- circuited. 264 V; 0,01 A; 1,0 W temperature (°C) of part Normal operation (according to clause 12.4 of IEC/EN 60598-1) 1,06 x 240 V = 254,4 V Limit Input terminal 56,8 105 Fuse surface 59,6 Ref. Capacitor X2, CX1 67,3 110 Inductor L2 78,6 100 Winding of T1 79,0 100 Capacitor, MPP1 70,1 100 Electronic Capacitor, C3 69,5 105 Winding of T2 72,2 100 PCB under T2 65,0 130 D7 76,2 Ref. Output terminal 57,8 105 Bottom enclosure under 68,5 75 PCB tc point (top enclosure 57,7 75 near to T2)

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.: 00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 34 of 43 http://www.tuv-sud.cn P.R.China

Attachment 3 IEC 61347-2-13 Clause Requirement + Test Result - Remark Verdict

Terminal cover 55,7 75 Mounting surface 57,4 90 temperature (°C) of part Abnormal operation – double load 1,1 x 240 V = 264 V Limit Capacitor X2, CX1 91,7 110+10 Inductor L2 108,6 150 Winding of T1 102,1 150 Capacitor, MPP1 92,3 100+10 Electronic Capacitor, C3 89,1 105+10 Winding of T2 90,9 150 tc point (top enclosure 77,7 75+10 near to T2) Mounting surface 76,1 130

Type reference ...... : OP-DY220/13.5-150CC ⎯ Load used ...... : Equivalent resistance load ⎯ Mounting position ...... : On black plywood (according ⎯ to H.12.2 in Annex H) ta ...... : 50 °C ⎯ - rated voltage ...... : 220-240 V ⎯ - test voltage (normal operation) ...... : Input: 254,4 V; 0,07A; 15,5 W; ⎯ output: 112,9 V; 150,4mA - test voltage (abnormal operation) ...... : 1. No lamp is inserted ⎯ 264 V; 0,01 A; 0,7 W 2. Double the LED modules or equivalent load 264 V; 0,06 A; 12,3 W 3. The output shall be short- circuited. 264 V; 0,01 A; 0,6W temperature (°C) of part Normal operation (according to I.6.2 and clause 12.4 of IEC/EN 60598-1) 1,06 x 240 V = 254,4 V Limit Input terminal 55,9 105 Fuse surface 57,9 Ref. Capacitor X2, CX1 59,7 110 Capacitor C5, 104K, 400V 63,0 100

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.: 00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 35 of 43 http://www.tuv-sud.cn P.R.China

Attachment 3 IEC 61347-2-13 Clause Requirement + Test Result - Remark Verdict

Electronic Capacitor, EC1 64,7 105 Winding of T1 71,2 100 PCB under T1 70,6 130 Q1 70,5 Ref. Output terminal 57.9 105 Bottom enclosure under 69,5 Ref. PCB tc point (top enclosure 61,1 75 near to T2) Terminal cover 54,0 75 Mounting surface 62,6 90 temperature (°C) of part Abnormal operation – double load 1,1 x 240 V = 264 V Limit Capacitor X2, CX1 77,0 100+10 Capacitor C5, 104K, 400V 80,0 100+10 Electronic Capacitor, EC1 82,1 105+10 Winding of T1 90,2 150 tc point (top enclosure 80,9 75+10 near to T1) Mounting surface 79,3 130

Type reference ...... : OP-DY220/8-150CC ⎯ Load used ...... : Equivalent resistance load ⎯ Mounting position ...... : On black plywood (according ⎯ to H.12.2 in Annex H) ta ...... : 50 °C ⎯ - rated voltage ...... : 220-240 V ⎯ - test voltage (normal operation) ...... : Input: 254,4 V; 0,07A; 9,8 W; ⎯ output: 64,2 V; 149,5mA

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.: 00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 36 of 43 http://www.tuv-sud.cn P.R.China

Attachment 3 IEC 61347-2-13 Clause Requirement + Test Result - Remark Verdict

- test voltage (abnormal operation) ...... : 1. No lamp is inserted ⎯ 264 V; 0,01 A; 0,6 W 2. Double the LED modules or equivalent load 264 V; 0,04 A; 7,5 W 3. The output shall be short- circuited. 264 V; 0,01 A; 0,4W temperature (°C) of part Normal operation (according to I.6.2 and clause 12.4 of IEC/EN 60598-1) 1,06 x 240 V = 254,4 V Limit Input terminal 55,2 105 Fuse surface 55,7 Ref. Capacitor X2, CX1 58,3 110 Capacitor C5, 104K, 400V 59,9 100 Electronic Capacitor, EC1 63,5 105 Winding of T1 73,5 100 PCB under T1 72,1 130 Q1 74,3 Ref. Output terminal 61,6 105 Bottom enclosure under 71,9 Ref. PCB tc point (top enclosure 62,0 75 near to T2) Terminal cover 56,1 75 Mounting surface 63,0 90 temperature (°C) of part Abnormal operation – double load 1,1 x 240 V = 264 V Limit Capacitor X2, CX1 72,8 100+10 Capacitor C5, 104K, 400V 74,3 100+10 Electronic Capacitor, EC1 77,7 105+10 Winding of T1 87,1 150 tc point (top enclosure 76,4 75+10 near to T1) Mounting surface 78,0 130

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.: 00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 37 of 43 http://www.tuv-sud.cn P.R.China

Attachment 3 IEC 61347-2-13 Clause Requirement + Test Result - Remark Verdict

Type reference ...... : OP-DY220/7-150CC ⎯ Load used ...... : Equivalent resistance load ⎯ Mounting position ...... : On black plywood (according ⎯ to H.12.2 in Annex H) ta ...... : 50 °C ⎯ - rated voltage ...... : 220-240 V ⎯ - test voltage (normal operation) ...... : Input: 254,4 V; 0,05A; 7,3 W; ⎯ output: 39,5 V; 149,7mA - test voltage (abnormal operation) ...... : 1. No lamp is inserted ⎯ 264 V; 0,01 A; 0,4 W 2. Double the LED modules or equivalent load 264 V; 0,04 A; 7,0 W 3. The output shall be short-circuited. 264 V; 0,01 A; 0,4W temperature (°C) of part Normal operation (according to I.6.2 and clause 12.4 of IEC/EN 60598-1) 1,06 x 240 V = 254,4 V Limit Input terminal 53,9 105 Fuse surface 54,3 Ref. Electronic Capacitor C2 56,9 105 Capacitor C1 58,6 100 Electronic Capacitor C5 56,9 105 Winding of T1 72,3 100 PCB under T1 71,0 130 Q1 66,8 Ref. Output terminal 56,4 105 Bottom enclosure under 66,4 Ref. PCB tc point (top enclosure 61,0 65 near to T1) Terminal cover 61,9 75 Mounting surface 54,7 90 temperature (°C) of part Abnormal operation – double load 1,1 x 240 V = 264 V Limit

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.: 00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 38 of 43 http://www.tuv-sud.cn P.R.China

Attachment 3 IEC 61347-2-13 Clause Requirement + Test Result - Remark Verdict

Electronic Capacitor C2 75,7 100+10 Capacitor C1 76,3 100+10 Electronic Capacitor C5 77,1 105+10 Winding of T1 86,0 150 tc point (top enclosure 74,8 65+10 near to T1) Mounting surface 74,8 130

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.: 00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 39 of 43 http://www.tuv-sud.cn P.R.China

Attachment 3 IEC 61347-2-13 Clause Requirement + Test Result - Remark Verdict

Attachment 3: European group differences and national differences P

ATTACHMENT TO TEST REPORT IEC 61347-2-13 EUROPEAN GROUP DIFFERENCES AND NATIONAL DIFFERENCES Part 2: Particular requirements Section Thirteen – d.c. or a.c. supplied electronic controlgear for LED modules Differences according to ...... : EN 61347-2-13:2006 used in conjunction with EN 61347-1:2008 + A1:2011 + A2:2013 Attachment Form No...... : EU_GD_IEC61347_2_13D Attachment Originator ...... : Intertek Semko AB Master Attachment ...... : Date 2013-10 Copyright © 2013 IEC System for Conformity Testing and Certification of Electrical Equipment (IECEE), Geneva, Switzerland. All rights reserved.

CENELEC COMMON MODIFICATIONS (EN) P No Common modifications P

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.: 00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 40 of 43 http://www.tuv-sud.cn P.R.China

Attachment 3 IEC 61347-2-13 Clause Requirement + Test Result - Remark Verdict

Attachment 4: Additional requirements of VC9087: 2009 for South Africa P

3 REQUIREMENTS P 3.1 Lamp controlgear shall be rated at the national 220-240V~ P standard low voltage, i.e. 230 V a.c. single phase or 400 V three phase, 50 Hz, or shall have a rated voltage range that includes 230 V / 400 V a.c. 3.2 Lamp controlgear shall be capable of operating P safely within the range +-10 % of the standard voltage. 3.3 Lamp controlgear shall comply with the safety P requirements of SANS 61347-1 (lEC 61347-1), Lamp controlgear- Parti: General and safety requirements. 3.4 SANS 61347-1 shall be used in conjunction with P the corresponding supplementary clauses of the appropriate part 2 of the SANS 61347 series applicable to each type of lamp controlgear. 3.5 The manufacturer or importer shall apply to the P Regulator for approval of every type and model of lamp controlgear before offering it for sale, in accordance with the requirements of Annex A. 3.6 The Regulator shall approve the lamp controlgear P when it has conformed with the requirements of this compulsory specification. 3.7 When a new edition of a standard is published, P approval of products in accordance with the previous edition of that standard shall remain valid for five years unless the Minister decides otherwise. 3.8 The manufacturer or importer (or both) shall P inform the Regulator of any change in design or components affecting any mandatory requirement in terms of this compulsory specification. In the event of such change the Regulator may, at its discretion, demand the submission of fresh evidence of conformily or a new application for approval. 3.9 The manufacturer or importer (or both) shall on P request provide the Regulator within 2 working days with satisfactory proof of approval in respect of any lamp controlgear included in the scope of this compulsory specification.

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.: 00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 41 of 43 http://www.tuv-sud.cn P.R.China

Attachment 3 IEC 61347-2-13 Clause Requirement + Test Result - Remark Verdict

3.10 The manufacturer or importer (or both) shall on P request provide the Regulator within five working days with satisfactory proof of conformity of production. 3.11 Failure to provide such proof shall constitute N/A reasonable grounds for suspicion of non- conformance with the requirements of this compulsory specification.

4 EQUIVALENCE OF STANDARDS --- Standards issued by different standardization bodies (for example, ISO, lEC, EN) --- that can be proved by the applicant to be technically identical to a South African National Standard are deemed equivalent to that South African National Standard. Proof of conformity with such a standard shall be accepted as conformity with the corresponding South African National Standard.

5 CONFORMITY WITH STANDARDS REFERRED TO BY EDITION AND DATE --- OF PUBLICATION 5.1 For purposes of this compulsory specification, a --- new edition of a standard shall become effective 2 months from the date of publication as a South African national standard. 5.2 New products, or products resubmitted for --- approval because of a change in design or materials shall in all cases be evaluated against the requirements of the latest edition of any referenced standard.

6 ASSESSMENT OF CONFORMITY P The following alternative forms of evidence shall be submitted to the Regulator as P proof of conformity with the requirements of this compulsory specification: 6.1 A copy of a valid certificate of lECEE conformity TUV IEC test report P issued less than 36 months before the date of application by a member of the lEC CB scheme; or 6.2 A copy of a valid test certificate or report issued P less than 36 months before the date of application by a conformity assessment body recognized by the Regulator. 6.3 The conformity or test certificate or report shall P prove conformity with all the applicable mandatory requirements of this compulsorv specification.

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.: 00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 42 of 43 http://www.tuv-sud.cn P.R.China

Attachment 3 IEC 61347-2-13 Clause Requirement + Test Result - Remark Verdict

6.4 Evidence of conformity shall be traceable to the Traceable P specific model and type of lamp controlgear in question.

ANNEX A APPROVAL OF LAMP CONTROLGEAR P 1 APPLICATION FOR APPROVAL P An application for approval of each type of lamp --- controlgear that it intends to sell shall include: a) Details of the type and model of lamp P controlgear for which approval is sought and the standard or standards to which it is claimed to conform; b) Details of the manufacturing plant or plants in P which the lamp controlgear is produced; c) Proof of conformity with all the requirements of P this compulsory specification including standards and test methods referred to; d) Markings and other information appearing on P the product; e) Any reasonable additional information P requested by the Regulator. 2 APPROVAL P 2.1 The Regulator shall assess the proof of P conformity supplied by the applicant. Additional information or evidence may be requested, or validation of evidence, at its sole discretion. 2.1 The Regulator shall approve the lamp controlgear Meet P when ail the requirements have been met. 2.3 The Regulator shall assign a unique number to P each approval.

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.: 00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 43 of 43 http://www.tuv-sud.cn P.R.China

Attachment No. 4 Clause Requirement - Test Verdict

Summary report of EMF (EN 62493:2010)

1 Scope -- General lighting equipment -- Lighting part for general lighting of multi-function equipment -- Independent auxiliaries exclusively for the use with lighting equipment -- Others, please specify: --

4 Limits -- 4.2 Lighting equipment, as described in the scope, complies with this standard if it fulfils P all of the following requirements See EN 62493:2010 test report with No.: 64.740.13.03702.02(F) 4.3 Lighting equipment deemed to comply without testing N/A Lighting equipment without electronic control gear is deemed to comply with the requirements of the standard without testing. All kind of ignitors, starters, switches, dimmers (including phase control units e.g. triac, GTO) and sensors are not considered as electronic control gear.

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.: 00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 1 of 1 http://www.tuv-sud.cn P.R.China

Attachment 5 IEC/EN 60598-2-6 Clause Requirement + Test Result - Remark Verdict

6.1 (0) SCOPE P 6.1 (0.1) More sections applicable ...... : Yes ⎯

6.4 (2) CLASSIFICATION N/A

6.5 (3) MARKING P 6.5.1(3) The rated supply voltage shall be marked on P luminaire in a position where it can be seen during maintenance 6.5.2(3) The rated output voltage shall be marked on the Lamp can’t replaced N/A luminaire in a position where it can be seen during lamp replacement 6.5.3(3) Warning sentence about difference of main P supply voltage and lamp voltage 6.5.4(3) Marking of transformer P 6.5.5(3) Marking of fuse link N/A

6.6 (4) CONSTRUCTION P 6.6.1 (4) Electrical safety output circuit P 6.6.2 (4) In class II luminaire in which the output poles are P accessible, the input and output winding, regard as reinforced insulation, shall comply with the requirement 6.6.3(3) Comply with clause 6.6.1 and 6.6.2 shall be P checked and inspected by section 10 of EN 60598-1

6.7 (11) CREEPAGE DISTANCES AND CLEARANCES P

6.8 (7) PROVISION FOR EARTHING N/A 6.8.1(7) The requirement for earthing shall apply to metal shell of lampholder which form N/A one connection to the lamp and is accessible to the lamp in position 6.8.2(7) If the secondary winding of transformer of class I luminaire is separated from N/A primary winding, then the secondary circuit is earthed, shall be earthed at only one point 6.8.3(7) Earthed metal other than shell of lampholder shall not form parts of current path N/A during normal operation

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Telephone : +86 20 38320668 5F, Communication Building, 163 Project No: 64.140.13.03702.02 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 1 of 2 http://www.tuv-sud.cn P.R.China

Attachment 5 IEC/EN 60598-2-6 Clause Requirement + Test Result - Remark Verdict

6.9 (14) SCREW TERMINALS P

6.9 (15) SCREWLESS TERMINALS P

6.10 (5) EXTERNAL AND INTERNAL WIRING P 6.10 (5.2) Supply connection and external wiring P 6.10 (5.3) Internal wiring P

6.11 (8) PROTECTION AGAINST ELECTRIC SHOCK P

6.12 (12) ENDURANCE TEST AND THERMAL TEST P 6.12(12) a) during endurance test, the voltage shall be P 1,1times nominal voltage b) during the test of normal operation, the test P voltage shall be 1,06 times nominal voltage except that transformer marked with Tw operated under rated voltage c) test order for luminiaire with IP greater than P IP20 6.13 (9) RESISTANCE TO DUST, SOLID OBJECTS AND MOISTURE P

6.14 (10) INSULATION RESISTANCE AND ELECTRIC STRENGTH P The test voltage between supply circuit and output circuit shall be as the test P voltage between supply circuit and body

6.15 (13) RESISTANCE TO HEAT, FIRE AND TRACKING P

COMMON MODIFICATIONS P ZB ANNEX ZB, SPECIAL NATIONAL CONDITIONS N/A

ZC ANNEX ZC, NATIONAL DEVIATIONS N/A

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Telephone : +86 20 38320668 5F, Communication Building, 163 Project No: 64.140.13.03702.02 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 2 of 2 http://www.tuv-sud.cn P.R.China

Attachment No. 6 Clause Requirement - Test Verdict

Additional requirements of VC8055 for South Africa P

3 REQUIREMENTS P 3.1 All apparatus shall be rated at the national standard P low voltage, i.e. 230 V ac, single-phase, 50 Hz, or 400 V ac, 3-phase, 50 Hz, or shall have a rated voltage range that includes 230 V/400 V ac. 3.2 All apparatus shall be capable of operating safely P within the range + - 10% of the standard voltage. 3.3 Household and similar electrical appliances shall N/A comply with the relevant requirements of SANS 60335-1 / IEC 60335-1 Household and similar appliances- safety, Part 1: General requirements, together with the appropriate Part(s) 2 of the SANS 60335 series. 3.4 Audio, Video, and similar electronic apparatus shall N/A comply with the relevant requirements of SANS 60065/IEC 60065 audio, video and similar electronic apparatus – Safety requirements. 3.5 Luminaires shall comply with the relevant requirements of the appropriate of the P following standards: a) SANS 60598-1/IEC 60598-1 Luminaires – Part 1: P General requirements and test, together with appropriate Part(s) 2 of the SANS 60598/IEC 60598 series (excluding Luminaires for emergency lighting); b) Luminaires shall additionally comply with the P power factor requirements of SANS 475 Luminaires for interior lighting, street and floodlighting – Performance requirements; c) Luminaires for emergency lighting shall comply N/A with SANS 1464-22 Safety of luminaries, Part 22: Luminaires for emergency lighting; d) electrical supply track systems for luminaries N/A shall comply with SANS 60570/IEC 60670 Electrical supply track systems for luminaries. 3.7 -held motor-operated or magnetically driven electric N/A tools shall comply with the relevant req Hand uirements of SANS 60745-111EC 60745-1 Hand- held motoroperated electric tools - Safety, Part 1: General requirements, together with the appropriate Part(s) 2 of the SANS 6074511EC 60745 series.

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.: 00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 1 of 3 http://www.tuv-sud.cn P.R.China

Attachment No. 6 Clause Requirement - Test Verdict

3.8 Transportable motor-operated electric tools shall N/A comply with the relevant requirements of SANS 61029-111EC 61029-1 Safety of transportable motor-operated electric tools Part 1: General requirements, together with the appropriate Part(s) 2 of the SANS 6102911EC 61029 series. 3.9 Electrical equipment for test and measurement, N/A control, and laboratory use shall comply with the relevant requirements of SANS 61010-1/1EC 61010-1 Safety requirements for electrical equipment for measurement, control and laboratory use Part 1: General requirements, together with the appropriate Parts(s) 2 of the SANS 61010llEC 61010 series. 3.10 The manufacturer or importer shall apply to the P Regulator for approval of every type and model of apparatus before offering it for sale, in accordance with the requirements of Annex A. 3.11 When a new edition of a standard is published, N/A approvals of products in accordance with the previous edition of that standard shall remain valid for five years unless decided otherwise by the Minister. 3.12 The manufacturer and/or the importer or both shall N/A inform the Regulator of any change in design or components that affects any mandatory requirement in terms of this compulsory specification. In the event of such change or changes the Regulator may, at its discretion, demand the submission of fresh evidence of conformity or a new application for approval. 3.13 The manufacturer and/or the importer or both shall N/A on request provide the Regulator within two working days with satisfactory proof of approval in respect of any apparatus included in the scope of this compulsory specification. 3.14 The manufacturer and/or importer shall on request N/A provide the Regulator within five working days with satisfactory proof of conformity of production.

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.: 00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 2 of 3 http://www.tuv-sud.cn P.R.China

Attachment No. 6 Clause Requirement - Test Verdict

3.15 Failure to provide such proof shall constitute N/A reasonable grounds for suspicion of non- conformance with the requirements of this compulsory specification. 4 EQUIVALENCE OF STANDARDS --- Standards issued by different standardization bodies (for example, ISO, IEC, EN) --- that can be proved by the applicant to be technically identical to a South African National Standard are deemed to be the equivalent of that South African National Standard. Proof of conformity with such a standard shall be accepted as conformity with the corresponding South African National Standard. 5 CONFORMITY WITH STANDARDS REFERRED TO BY EDITION AND --- DATE OF PUBLICATION 5.1 For the purposes of this compulsory specification, a N/A new edition of a standard shall become effective two months from its date of publication as a South African National Standard. 5.2 New products or products resubmitted for approval N/A because of a change in design or materials shall, in all cases, be evaluated against the requirements of the latest edition of any referenced standard. 6 ASSESSMENT OF CONFORMITY --- 6.1 The following alternative forms of evidence shall be submitted to the --- Regulator as proof of conformity with the requirements of this compulsory specification: a) Copy of a valid certificate of IECEE conformity P issued by a member of the IEC CB scheme; or b) Copy of a valid test certificate issued less than 36 P months prior to date of application by a test laboratory recognized by the Regulator. 6.2 The certificate or test report shall prove conformity P with all the applicable mandatory requirements of this compulsory specification. 6.3 S.3 Evidence of conformity shall be traceable to the P specific model and type of apparatus in question.

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangZhou Branch TÜV SÜD Group

Project No: 64.140.13.03702.02 Telephone : +86 20 38320668 5F, Communication Building, 163 Rev.: 00 Telefax : +86 20 38320478 Pingyun Rd, Huangpu Ave. West, Date: 2015-03-11 Guangzhou, 510656 Page: 3 of 3 http://www.tuv-sud.cn P.R.China