<<

Polywell – A Path to Electrostatic Fusion

Jaeyoung Park Energy Matter Conversion Corporation (EMC2) University of Wisconsin, October 1, 2014

1 Fusion vs.

For a 50 cm radius spherical IEC device - Area projection: πr2 = 7850 cm2 à 160 for same size solar panel

Pfusion =17.6MeV × ∫ < συ >×(nDnT )dV

For D-T: 160 Watt à 5.7x1013 n/s -16 3 <συ>max ~ 8x10 cm /s 11 -3 à ~ 7x10 cm

Debye length ~ 0.22 cm (at 60 keV)

Radius/λD ~ 220

In comparison, 60 kV well over 50 cm 7 -3 (ne-ni) ~ 4x10 cm 200 W/m2: available solar panel capacity 0D Analysis - No convergence case

2 Outline

Fusion:

- Electrostatic Fusion + Magnetic Confinement

• Lessons from WB-8 experiments

• Recent Confinement Experiments at EMC2

• Future and Summary

3 Electrostatic Fusion

Fusor polarity Contributions from Farnsworth, Hirsch, Elmore, Tuck, Watson and others Operating principles (virtual cathode type ) • e-beam (and/or grid) accelerates into center • Injected electrons form a potential well • Potential well accelerates/confines Virtual cathode • Energetic ions generate fusion near the center polarity Attributes • No ion grid loss • Good ion confinement & ion acceleration • But loss of high energy electrons is too large

4 Polywell Fusion

Combines two good ideas in fusion research: Bussard (1985) a) Electrostatic fusion: High energy beams form a potential well, which accelerates and confines ions b) High β magnetic cusp: High energy electron confinement in high β cusp: Bussard termed this as “wiffle-ball” (WB).

+ + +

e- e- e-

Potential Well: ion heating &confinement Polyhedral coil cusp: electron confinement

5 Wiffle-Ball (WB) vs. Magnetic Grid (MaGrid)

WB6 Schematics

- Coil shells are biased to + HV - Electron injectors & chamber at ground potential - +HV on coil accelerates electrons to the center - WB will form once the core reaches sufficient (with power from coil shell) MaGrid in Operation - Electron recirculation improves confinement

6 Wiffle-Ball 7 Results

Neutron yield estimate vs applied 1.2 106 6 1 10 From 164 counts 8 105 over 96 shots 6 105 4 105

2 105 Neutron Yield Neutron (n/s) Yield 0 -2 105 10 11 12 13 14 15 16 6 coil system with joints Applied Voltage (= Ballast voltage + WB7 voltage) WB7 voltage (kV) Neutron signal statistics shots 31- 40 WB-7 current Pearson(A)

0.05 80 (A) current and (kV) voltage WB7 shot 31 - 14kV 0.04 shot 32 - 14 kV 60 - Synchronous shot 33 - 14 kV 0.03 puff shot 34 - 15 kV duration detection of 0.02 shot 35 - 15 kV 40 shot 36 -15 kV shot 37- 15 kV - Reasonable neutron 0.01 20 shot 38- 15 kV yields despite low bias 0 shot 39 - 15 kV

Neutron signal(a.u.) 0 -0.01 6-18-08 Data set -0.02 -20 - Confirms WB-6 results 0 5 10 15 20 Time (ms)

7 Wiffle-Ball 8 Experiments

Two major improvements over WB-7

- WB-8 has externally held coils without joints - WB-8 has an arc plasma source to initiate high density plasmas in the core

Powerful plasma heating to achieve high plasmas and wiffleball - Grid bias: up to 2 kA @50 kV (500A @ 15kV for WB-7) - Arc source: 500A arc source for plasma start- up (None for WB-7) - 8 Electron injectors:10A per gun ( ~1-2A/gun for WB-7) - Ion injection: 1 MW (40A at 25 kV) via NBI (None for WB-7)

8 Comparison of WB-7 and WB-8

WB-8 grid current WB-7 grid current 15 60

50 (A) current WB-7 grid

10 40

30

5 20

WB-8 grid curent (A) 10

0 0 0 5 10 15 20 Grid Bias Voltage (kV) For the same grid bias: WB-8 operate with lower grid current than WB-7, while WB-8 has 6x higher plasma density (WB-8: 3x1012 cm-3 and WB-7: 5x1011 cm-3) à No coil joints à Operates with higher B-fields (2 kG for WB-8 and 1 kG for WB-7)

10/2/14 9 Plasma density decay vs. grid bias

B-field at 2.0 kG, Arc source on for 3 ms, no electron injection and no NBI

0.7 kV 2.7 kV 800

6.2 kV (A) current Arc source 8.7 kV 600 12.0 kV

) 12

-3 10 400

200 Ne (cm 0 Arc source current (A) 1011 -200 4 4.1 4.2 4.3 4.4 4.5 time (ms)

No change in ne decay time (~180 µs) vs. grid bias voltage

10/2/14 10 HV bias on the grid alone cannot sustain plasma density Shot 10625: B-field at 2 kG, 13.2 kV bias, HV with arc source 15 20 grid current (A) current grid 15 10 grid voltage (kV) 10 5 5 grid current (A) 0 0

grid voltage (kV) -5 -5 1000 (A) source current arc 1012 electron

) density 500 -3 1011 (cm e 0 n arc

10 current 10 -500 -2 0 2 4 6 8 10 time (ms) HV bias and no other source terms à Low electron density

10/2/14 11 Plasma potential measurement

Shot 11010: 2kG, 4 kV bias and arc source (no e-guns)

Corner cusp emissive probe (in kV)

Plasma potential at the corner cusp drops to 0V with increasing plasma density à Grid biasing does not look promising for Potential Well formation

10/2/14 12 Motivation for Cusp Confinement

Reference: “: The U. S. Program in Controlled Fusion” by Bishop (1958).

• Question on by Teller in 1954 - “Attempts to contain a plasma as somewhat similar to contain jello using rubber bands” - Basis of interchange (plasma version of Rayleigh Taylor instability) and idea of “good curvature” vs. “bad curvature”

• Preliminary analysis (by Frieman in 1955) indicated and would be unstable not just at high β but at all values of β. (β = plasma pressure/)

• By 1957, several concepts such as magnetic shear, field line tying and rotating plasmas were introduced to stabilize stellarator and mirror. However, it is understood that there would be undesirable limits on maximum plasma β in many of magnetic fusion concepts.

• ITER design calls for β to be 0.03, while the output scales as β2 for a fixed value. H. York at Livermore was concerned that “the limitation on β might so reduce the net power output that this device (stellarator) could never be of economic interest” and started magnetic mirror program at Livermore.

13 Cusp Confinement Configuration

Picket Fence Low β

Finite B-field (center) Weak

Plasma High β

Zero B-field (center) Strong diamagnetism Conceived by Tuck in 1954 Conjectured by Grad (from Bishop’s book)

14 Brief History of Cusp Confinement

• Picket-Fence (cusp confinement) concept by Tuck is the first stable magnetic confinement scheme against . The entire region of confined plasma faces magnetic fields with good curvature. As such, good plasma stability has been observed in many cusp experiments.

• However, original picket fence approach was quickly abandoned due to rapid plasma loss along the open field lines, meaning good stability comes with bad confinement.

• Between 1955-1958, NYU group led by Grad investigated the case of high β confinement in magnetic cusp. Their result was the plasma confinement would be greatly enhanced for a high β plasma in the cusp, compared to a low β plasma.

• This confinement enhancement conjecture made the cusp approach to be promising. For the next 20 years, detailed experiments were conducted on ~20 different devices and ~200 papers were published related to the cusp confinement as a result. Two excellent review articles by Spalding (1971) and Haines (1977).

• However, most efforts on cusp confinement stopped by 1980 due to a lack of progress.

15 Plasma Confinement in Cusp at Low β

Low β cusp confinement can be modeled as “magnetic mirror” with particle transit time as a scattering time to loss cone: due to non-conserved magnetic moment near r=0

τ (r , E , B ) ≈ (2r /υ )× M * or ∝ (r )1.75 × E −7/8 × B 3/ 4 e coil e max coil e coil e max 1 µs confinement time where is a electron velocity at E , M * is an effective mirror ratio, B /B* υe e max min for 100 keV electron with 7 1 dB 1 and B* is given as × (r = r ) = T, 1 m, 6 coil cusp – will not min B dr adibatic A r (E ,B* (r r )) × Lamor e min = adibatic work for a net power device and A is a constant between 3-5 for a given magnetic field profile

16 Plasma Confinement in Cusp at High β

Berkowitz et al 1958 paper “Cusped geometries”

In high β cusp, a sharp transition layer exists between plasma and B-fields. Plasma particles will undergo specular reflection at the boundary except for the particle moving almost exactly in the direction of the cusp. The loss rate will have gyro-radius scaling.

Theoretically conjectured 0.5s confinement time Loss current per cusp by Grad and NYU team for 100 keV electron with 7 T, 1m, Ie,i π gyro 2 6 coil cusp à favorable for a net = n υ × π(r ) e 9 e,i e,i e,i power device.

17 What were the challenges on High β cusp?

1. How to form high β plasma in a leaky cusp: start up problem - Use of (pulsed) high power plasma injectors or laser ablation - Typical injector produce cold plasmas 10-50 eV - β=1 plasma were achieved with strong diamagnetism and good stability 2. Which loss rate is correct? - Question on ion gyro-radius vs. electron gyro-radius - Ion gyro-radius will not work for fusion: experiments indicated ion gyro-radius 3. How to heat initial cold plasmas to fusion relevant ? - Magnetic compression and shock heating was suggested and tried without much success. 4. How to measure plasma confinement or confinement enhancement? - Experiments lasted only for a short period (due to high power injector), while the predicted confinement time was long. Success on #1, but results on #2 appeared not favorable No promising solutions were presented for #3 and #4. à end of cusp by 1980

18 Recent Experiments at EMC2 (EMC2 San Diego Facility)

WB-8 Device

High β cusp Test Device

19 High β cusp test device installation

Locations of 6 coil cusp installation

20 Experimental Plan

1. Plasma injection to the cusp - Use high power arc (solid target) plasma injectors 2. Verify high β plasma formation in the cusp

- Measurements on plasma density, magnetic flux and electron 3. High energy electron injection to high β cusp

- LaB6 based electron beam injector, sufficient for diagnostics but not for potential well formation 4. Confinement measurement of high energy electrons in the cusp - Time resolved hard x-ray intensity from

Bulk (cold & dense) plasma from arc injectors provides plasma pressure (high β) to modify cusp B-fields, while the confinement property is measured for high energy electrons in the cusp.

21 Experimental Setup for high β cusp confinement

LaB6 Electron Gun (7 keV, 1 – 3 A) Plasma Gun (300 MW solid arc)

X-ray diode (2 keV x-rays and up, corner and face views) Chamber size: 45 cm cube, Coil major radius; 6.9 cm Distance between two coils: 21.6 cm, B-field at cusp (near coil center) 0.6 – 2.7 kG

22 Experimental Setup (continued)

Laser Interferometer (532 nm, 1015 -1017 per cc)

Magnetic Flux Loops

Photodiodes and Spectrometer

(Filtered for Hα and CI-II, High resolution spectrometer, fiber coupled)

23 Solid arc plasma injector

Plasma injection by co-axial guns (j x B) using solid - Ignitron based pulse power system (40 µF cap holds 3 kJ at 12kV) - ~100 kA arc current à ~300 MW peak power and ~7 µs pulse - β=1@ 2.5 kG: 1.5x1016 cm-3 at 10 eV or 100J in a 10 cm radius sphere

solid arc using polypropylene film 2 mm A-K gap Animation of plasma injection Dual arc plasma injection movie

24 High β plasma formation

Gas gun Two Guns C III Left Gun [465 nm] C II [513 nm] H [515 nm] [486 nm]

- Electron temperature is estimated - Plasma density on the order of 1016 cm-3 ~ 10 eV from C II and CIII emission from Stark broadening of Hα line - Hα, C II line by photodiode and visible - Laser interferometer provides single shot spectra by gated CCD is used to monitor Te line integrated density variation in time variation in time

25 High energy electron beam produces hard x-rays

E-gun injects Beam Electrons (7 keV)

X-rays X-rays

X-rays Beam electron confinement by X-rays Cusp magnetic fields

Collisions with bulk plasma B-field Bulk Plasma create hard x-rays (E > 2 keV) via Bremsstrahlung Transit time: ~7 ns for 7 keV electron for 22 cm transit Expected confinement time: ~45 ns for low β and ~18 µs for high β (x400 increase)

26 Bremsstrahlung x-ray emission from interaction between beam electrons and plasma

Bremsstrahlung from e-beam interaction with plasma ions Br beam 1/ 2 2 e + ion à e + ion + hν P n E n Zeff ∝ e beam ion

Bremsstrahlung x-ray intensity à Direct measurement of beam e-density inside Cusp

Careful measurement is required to eliminate spurious radiation from impurities, wall, coil surfaces, and characteristic line emission

Typical beam target x-ray spectrum

27 X-ray collecting optics to eliminate unwanted signals

X-ray Diode and Collimator Assembly

B-field

Silicon Diode Detector

Kapton-Black Film Magnetic Yoke Collimator Tube • Blocks plasma • Blocks beam • Limits view to plasma • Blocks soft x-rays electrons • Plastic material minimizes • Blocks visible light x-ray production inside tube

28 Hard x-ray filter

Magnetic yolk to eliminate charge particles

25 µm thick light tight Kapton filter (works as vacuum interface)

Filter has sharp cutoff at ~2 keV photon energy

à blocks any characteristic x-ray emission from light elements up to 14Si and 15P à blocks UV-visible light from plasmas à blocks charged particles from reaching the detector

29 Spatial collimation of x-ray detectors

Corner cusp chord

Face cusp chord

• Collimation is designed to eliminate direct line-of-sight view of metal surfaces • In addition, opposite sides of the chamber wall are covered using Kapton film and quartz window • Both chords allow good volume averaging of x-ray emission from core plasmas

30 First ever confirmation of high β cusp confinement enhancement (October 23, 2013)

High β shot 15610

1 n e bulk bulk n High β Phase Flux (%) exclusion 0.8 e 16 of (in10 unit X-ray from 0.6 X-ray face X-ray corner impurities (e.g. W) 0.4 8

0.2 ΔB 15 cm -3 X-ray intensity (a.u.) 0 0 )

Face and corner cusp chord 8 6 -0.210 0.6 intensity emission (a.u.) 4 108

Ηα line intensity 0.4 H α

2 108 , CII 0.2 0 0 1/2 Arc Input1/2 Power (W) CII line intensity -2 108 0 10 20 30 40 50 60 70 80 Time (µs)

31 Reproducibility of high β cusp confinement

6 consecutive shots with ~ 200 J of injected plasma energy at 2.7 kG B-fields à estimated beta ~ 0.7 and 10% measured flux exclusion

shot 15635 shot 15636 1.2 shot 15637 High phase β shot 15638 shot 15639 0.8 shot 15640

0.4 Face cusp signal x-ray 0

0 20 40 60 80 Shot 15638 Shot Time15639 (µs) Shot 15640 All six shots show distinctive high β phase à good reproducibility

32 High β cusp shot 15640 (Oct 25,2013) Magnetic flux exclusionMagnetic (in 10

1.5 15 10 (in Electron density High ΔΦ β confinement phase 1 X-ray face 10 X-ray corner bulk 0.5 n 5 e 15 cm X-ray intensity (a.u.) -5 -3 0 0 Wb) ) Face and corner cusp chord 0.6 800 Arc input power (MW) power input Arc

0.3 C II line intensity 400 H line intensity α and C II and C α 0

H 0 Arc input power line emission intensity (a.u.) intensity line emission -0.3 -400 -10 0 10 20 30 40 50 60 Time (µs) - Hard x-ray signals exhibit very distinctive features between 14 µs and 19 µs

33 How to interpret x-ray signals

- We have a set of data which shows that the broad x-ray peaks between 40-50 µs come from e-beam interaction with impurities. - Electron beam turns on 30 µs before plasma injection and turns off at t=150 µs - X-ray intensity is low (nearly zero) initially even after bulk density reaches its peak following plasma injection. - Onset of the x-ray signal increases comes shortly after the peak of flux exclusion - During the high β phase, the hard x-ray intensity from beam electron interaction with bulk plasma increases by a factor of~20 or more , while the bulk plasma density varies less than a factor of 2. - At the end of the high β phase, the x-ray signals decrease very rapidly within 1-2 µs. No other plasma quantities change this fast during this period. Since the x-ray measurement is volume averaged, the only possible explanation is a sudden decrease of beam electron confinement. - Decay of high β phase is expected since arc injectors were designed to inject high β plasma in the cusp but not to sustain it.

34 Time resolved spectroscopy on W-impurity

Tungsten cathode after 200 shots

• Line emission intensities from main ion species (H and C) decay early • Despite plasma density decay (& cooling of plasma), Tungsten line intensities peak later in time and decay slowly --> indicates gradual build up of Tungsten impurity. --> x-ray peak late in the shot (40-50 µs) is from e-bam interaction with Tungsten

35 Cusp confinement vs. Injection input power

0.5

0.4 shot 15631@220 MW 0.3 shot 15650@340 MW shot 15630@450 MW 0.2 shot 15640@700 MW B-field at 2.7 kG 0.1 injection (a.u.) e X-ray intensity

/ I / 0 0.2 3 1016 -0.1 (cm density electron Bulk

0.1 2 1016

0 1 1016

-0.1 0 Flux exclusion (mWb)Flux -3

-0.2 ) -10 0 10 20 30 40 50 60 Time (µs) Cusp confinement enhancement requires sufficiently high β plasma condition

36 Cusp confinement vs. initial B-fields

0.5

0.4 shot 15621@B=0 shot 15677@B=0.6 kG 0.3 shot 15640@B=2.7 kG 0.2 Input power at 700 MW 0.1 X-ray intensity 0 / Electron/ current (a.u.) -0.10.2 3 1016 Bulk electron density (cm density electron Bulk shot 15621@B=0 shot 15677@B=0.6 kG 16 0.1 2 10 shot 15640@B=2.7 kG 0 1 1016

-0.1 0 Flux exclusion (mWb)Flux -3

-0.2 ) -10 0 10 20 30 40 50 60 Time (µs) No confinement enhancement at B=0 but we need to do more to understand B-field effects

37 Our Findings on High β Cusp Confinement

Increase in X-ray signal

- Coincides with high β plasma state in the cusp - Only observed when there is sufficient flux exclusion or plasma injection reaches a threshold - Peak increase is 10-20x or more compared to low β state - Exhibits asymmetrical time behavior: gradual increase followed by rapid decrease - Clearly separated from W impurities injection in time domain

We believe our x-ray measurements unambiguously validate the enhanced electron confinement in a high β cusp compared to a low β cusp

38 Unresolved issues on high β cusp

1. Decay of good confinement phase

- Decay mechanism: plasma loss/plasma cooling or magnetic field diffusion or something else - How to extend high β state and prevent the decay 2. Topological information on cusp magnetic fields during high β state

- Thickness of transition layer - Magnetic field lines near the cusp openings

39 Future Work

High β cusp Electric fusion (Confinement of (Potential well for energetic electrons) energetic ions) Proven in 2013 Proven in 1995

Polywell

High β cusp + Electric fusion at the same time

40 Summary

• Time resolved hard x-ray measurement provide the first ever direct and definitive confirmation of enhanced plasma confinement in high β cusp, a theoretical conjecture made by Grad and his team in 1950s. • The enhanced electron confinement in high β cusp allows the Polywell fusion concept to move forward to complete the proof-of-principle test. • If proven, Polywell device may become an attractive fusion reactor due to the following attributes - stable high pressure operation from cusp - good electron confinement by high β cusp - ion acceleration and confinement by electric fusion

41 Supplemental Slides

42 Fusion Research in 1958 From “ProjectFrom Sherwood: Program S. inTheU. AmasaBishop (1958). ControlledFusion” by Polywell Cusp Magnetic Fields

6 coil Polywell magnetic field lines

44 Confirmation of X-ray collimation

0.1 2 beam current 7 at current (A) kV beam

0.05 1

0 0 X-ray signal (face &X-ray corner) signal -0.05 -1 -150 -100 -50 0 Image plate (x-ray film) exposure Time (µs) at the face cusp detector location - e-beam into vacuum magnetic field - Uniform exposure (no plasma) generates no x-ray - No sign of spatial structure from coils & walls response from the diode detector - 10 mTorr N2 gas target - Indication of well collimated x-ray - 20 ms exposure with 4A@7 kV e-beam optics - B-field at 1.4 kG

45 Confirmation of X-ray filter vs. beam energy

1.5

1 • X-ray was generated by electron beam on Stainless 0.5 Steel target

X-ray signal • 25 µm thick Kapton filter 0 works well to eliminate X-ray photons below 2 keV -0.5 0 2 4 6 8 Electron beam voltage (kV)

46 Time resolved spectroscopy for impurity transport

Visible emission spectrum between 12 µs and 20 µs

During the high β phase, plasma emission shows strong C+ lines & presence of W+ lines 16 -3 (Note that avg. ne ~ 1.5x10 cm and Te ~ 10 eV during this period)

47 Time resolved spectroscopy (cont.)

Visible emission spectrum between 42 µs and 50 µs

At later time, plasma emission is dominated by W neutral lines, while C+ and W+ lines disappear 16 -3 (Note that avg. ne ~ 0.2x10 cm and Te < 10 eV)

48 Estimate of High β Confinement Time

Theoretical model Experimental results to estimate high β confinement time Shot 15640 1

0.8 1.2

0.6 0.8 (t=0) e

0.4 0.4 (t) - n e Characteristic time n of density rise 0.2 0 ~ τ t ~ 5 s WB Δ µ 0 10 15 20 25 0 1 2 3 Time (µs) WB Time (t/τ ) - Note the shape of x-ray intensity profile: a gradual rise and a rapid drop - From time response of x-ray signal à τ >2.5 µs (2x τ ~ x-ray signal rise time) - 2.5 µs is about ~ 50 times better than low β cusp confinement time - The observed confinement enhancement is very significant and compares well with the theoretically predicted high β cusp confinement time by Grad and his team

49 Time averaged plasma images

Shot 15635 Shot 15636 Shot 15637

Shot 15638 Shot 15639 Shot 15640

High β cusp formation: intense plasma in the core region

50