SECTION 08745 ELECTRICAL LOCKING SYSTEMS

(When editing, display hidden text notes to specifier.) ** NOTE TO SPECIFIER ** Security Door Controls; electromagnetic locks, delayed egress locking systems, electrified mortise and cylindrical locks, electric bolt locks, electric strikes, power supplies, access controls, request-to-exit push bars, electrical locking system accessories.

This section is based on the products of Security Door Controls., located at: 3580 Willow Lane. Westlake Village, CA 91361 Tel: 805-494-0622 Tel: 800-413-8783 (toll free) Fax: 805-494-8861

www.sdcsecurity.com

PART 1- GENERAL

1.1 SECTION INCLUDES ** NOTE TO SPECIFIER ** Delete items below not required for project.

A. Electromagnetic locks.

B. Delayed egress locking systems.

C. Electrified mortise and cylindrical locks.

D. Electric bolt locks.

E. Electric strikes.

F. Power supplies.

G. Access controls.

H. Request-to-exit push bars.

I. Electrical locking system accessories.

1.2 REFERENCES

A. Builders Hardware Manufacturers Association (BHMA): 1. BHMA A156 Standards for Door Hardware.

B. National Fire Protection Association (NFPA): 1. NFPA 101 Life Safety Code.

C. Underwriters Laboratories Inc. (UL): 1. UL Standards for Electrified Locking Equipment and Power Supplies.

1.3 SUBMITTALS

A. Submit under provisions of Section 01300.

B. Shop Drawings: Door Schedule showing each item of hardware to be installed on each door.

ELECTRICAL LOCKING SYSTEMS 08745 - 1 1. Use Architect's door numbers on schedule. 2. Schedule may be combined with submittals required in other door hardware sections. 3. Description and Sequence of Operation of each electrified door hardware function, including location, and interface with fire alarm, access control, and security systems as applicable. Include description of component functions that occur when authorized person wants to enter; authorized person wants to exit; unauthorized person wants to enter; and unauthorized person wants to exit.

C. Product Data: Manufacturer's data sheets on each product to be used, including installation instructions.

D. Operating and Maintenance Data: Include operating, troubleshooting, maintenance, and repair instructions for each item, with lists of spare parts, if any, and name, address, and phone number of local stocking distributors.

1.4 QUALITY ASSURANCE

A. Manufacturer: ISO 9001 certified.

B. Installer Qualifications: Experienced door hardware installer.

1.5 DELIVERY, STORAGE, AND HANDLING

A. Store products in manufacturer's unopened packaging until ready for installation.

PART 2- PRODUCTS

2.1 MANUFACTURERS

A. Acceptable Manufacturer: Security Door Controls (SDC), 3580 Willow Lane, Westlake Village, CA 91361. Phone 800-413-8783; Fax 805-494-8861; www.sdcsecurity.com. ** NOTE TO SPECIFIER ** Delete one of the following two paragraphs; coordinate with requirements of Division 1 section on product options and substitutions.

B. Substitutions: Not permitted.

C. Requests for substitutions will be considered in accordance with provisions of Section 01600.

2.2 MATERIALS

A. General Requirements: Provide devices suitable for door type, lock type, frame type, dimensions and overall operation. 1. Coordinate with doors, frames, and hardware specified in other sections. 2. Provide all brackets, spacers, shims, lip extensions, strike boxes, and other accessory parts necessary to complete the installation. 3. Provide all necessary components to supply power to devices from building power distribution system.

2.3 ELECTROMAGNETIC LOCKS ** NOTE TO SPECIFIER ** The following are direct-pull type electromagnetic locks with holding force of 1650, 1200, and 650 pounds. Delete all that are not required. If more than one type of lock is required, give each a type designation and indicate type on Door Schedule.

A. Electromagnetic Locks, 1650 lb Holding Force: SDC 1511-1542 Series locks shall be surface mounted and include all necessary mounting hardware. Core shall not contain any epoxy-resin, and consist of steel laminations welded in a steel U-Channel. The

ELECTRICAL LOCKING SYSTEMS 08745 - 2 winding and electronics to be contained within the aluminum housing and be replaceable without removing the lock from the doorframe. 1. Holding force shall be 1650 lbs. 2. Locks operate with 12 or 24VDC power input without field selection. Current required shall not exceed 670 mA @ 12VDC or 350 mA @ 24VDC for single lock and 1.34 Amp @ 12VDC or 700 mA @ 24VDC for double lock. 3. All field wiring connections shall be via on-board screw terminal connections. Magnetic lock shall contain printed-circuit board providing circuit and surge protection. 4. Locks shall be BHMA Certified Grade 1 ranking. 5. Locks shall be listed by Underwriters Laboratories as Auxiliary Locks (GWXT) and as Burglary resistant electrically operated door locking mechanism (CVXJ). 6. Locks shall comply with UL10C standards for positive pressure fire rated doors. ** NOTE TO SPECIFIER ** The following paragraphs are optional. Delete if not required. 7. Locks shall have a door position switch (DPS) to allow monitoring of the open/closed status of the door. 8. Locks shall have a magnetic bond-sensor (BA) circuit to allow monitoring of the strength of the magnetic field between lock and armature. 9. Locks shall have an anti-tamper switch (ATS) to indicate an attempt to remove cover. 10. Locks shall have tri-color LED Status Indicator (L3): Green, Red, Yellow. 11. Locks shall be enclosed in full opening width housing. 12. Pairs of Doors Without Mullion: Provide both locks in a single housing. ** NOTE TO SPECIFIER ** Delete the following paragraphs for finishes not required. 13. Case Finish: 628 Satin Aluminum, Clear Anodized 14. Case Finish: 313 Dark Bronze Anodized 15. Case Finish: 335 Black Duronodic 16. Case Finish: 605E Bright Brass Anodized 17. Case Finish: 606E Satin Brass Plated 18. Case Finish: 611E Bright Bronze Plated 19. Case Finish: 625E Bright Chromium Plated 20. Case Finish: 626E Satin Chromium Plated

B. Electromagnetic Locks, 1200 lb Holding Force: SDC 1571-1572 Series locks shall be surface mounted and include all necessary mounting hardware. Core shall not contain any epoxy-resin, and consist of steel laminations welded in a steel U-Channel. The winding and electronics to be contained within the aluminum housing and be replaceable without removing the lock from the doorframe. 1. Holding force shall be 1200 lbs. 2. Locks shall operate with 12 or 24VDC power input without field selection.. Current required shall not exceed 250 mA @ 12VDC or 125 mA @ 24VDC. 3. All field wiring connections shall be via on-board screw terminal connections. Magnetic lock shall contain printed-circuit board providing circuit and surge protection. 4. Locks shall be BHMA Certified Grade 2 ranking. 5. Locks shall be listed by Underwriters Laboratories as Auxiliary Locks (GWXT) and as Burglary resistant electrically operated door locking mechanism (CVXJ). 6. Locks shall comply with UL10C standards for positive pressure fire rated doors. ** NOTE TO SPECIFIER ** The following paragraphs are optional. Delete if not required. 7. Locks shall have a door position switch (DPS) to allow monitoring of the open/closed status of the door. 8. Locks shall have a magnetic bond-sensor (BA) circuit to allow monitoring of the strength of the magnetic field between lock and armature. 9. Locks shall have an anti-tamper switch (ATS) to indicate an attempt to remove cover. 10. Locks shall have tri-color LED Status Indicator (L3): Green, Red, Yellow.

ELECTRICAL LOCKING SYSTEMS 08745 - 3 11. Locks shall be enclosed in full opening width housing. 12. Pairs of Doors Without Mullion: Provide both locks in a single housing. ** NOTE TO SPECIFIER ** Delete the following paragraphs for finishes not required. 13. Case Finish: 628 Satin Aluminum, Clear Anodized 14. Case Finish: 313 Dark Bronze Anodized 15. Case Finish: 335 Black Duronodic 16. Case Finish: 605E Bright Brass Anodized 17. Case Finish: 606E Satin Brass Plated 18. Case Finish: 611E Bright Bronze Plated 19. Case Finish: 625E Bright Chromium Plated 20. Case Finish: 626E Satin Chromium Plated

C. Electromagnetic Locks, 650 lb Holding Force: SDC 1580 Series locks shall be surface mounted and include all necessary mounting hardware. Core shall not contain any epoxy-resin, and consist of steel laminations welded in a steel U-Channel. The winding and electronics to be contained within the aluminum housing and be replaceable without removing the lock from the doorframe. 1. Holding force shall be 650 lbs. 2. Locks shall operate with 12 or 24VDC power input with out field selection.. Current required shall not exceed 440 mA @ 12VDC or 220 mA @ 24VDC for single lock and 880 mA @ 12VDC or 440 mA @ 24VDC for double lock. 3. All field wiring connections shall be via on-board screw terminal connections. Magnetic lock shall contain printed-circuit board providing circuit and surge protection. 4. Locks shall be BHMA Certified Grade 3 ranking. 5. Locks shall be listed by Underwriters Laboratories as Auxiliary Locks (GWXT) and as Burglary resistant electrically operated door locking mechanism (CVXJ). ** NOTE TO SPECIFIER ** The following paragraphs are optional. Delete if not required. 6. Locks shall have a door position switch (DPS) to allow monitoring of the open/closed status of the door. 7. Locks shall have a magnetic bond-sensor (BA) circuit to allow monitoring of the strength of the magnetic field between lock and armature. 8. Locks shall have tri-color LED Status Indicator (L3): Green, Red, Yellow. 9. Pairs of Doors Without Mullion: Provide both locks in a single housing. ** NOTE TO SPECIFIER ** Delete the following paragraphs for finishes not required. 10. Case Finish: 628 Satin Aluminum, Clear Anodized 11. Case Finish: 313 Dark Bronze Anodized 12. Case Finish: 335 Black Duronodic 13. Case Finish: 605E Bright Brass Anodized 14. Case Finish: 606E Satin Brass Plated 15. Case Finish: 611E Bright Bronze Plated 16. Case Finish: 625E Bright Chromium Plated 17. Case Finish: 626E Satin Chromium Plated ** NOTE TO SPECIFIER ** The following are shear type electromagnetic locks with holding force of 2700 and 2000 pounds. Delete all that are not required. If more than one type of lock is required, give each a type designation and indicate type on Door Schedule.

D. Electromagnetic Shear Locks, 2700 lb Holding Force: SDC 1565-1566 Series locks shall be mortise mounted and shall be provided with all required mounting hardware. Shear Lock design shall incorporate shear stops to prohibit horizontal shear motion. Units shall provide for both lateral and vertical field adjustment. Model 1566 shall be capable of being fit into 1-1/4 inch face frame. 1. Holding force shall be 2700 lbs. 2. Locks shall operate with 12 or 24VDC power input without field selection. Current required shall not exceed 800 mA @ 12VDC or 400 mA @ 24VDC.

ELECTRICAL LOCKING SYSTEMS 08745 - 4 3. Locks shall incorporate automatic relock with 1 to 5 second delay relock timer, and shall include circuitry for voltage kickback suppression. 4. Locks shall be listed by Underwriters Laboratories as Auxiliary Locks (GWXT). 5. Finish: Satin Nickel Plated. ** NOTE TO SPECIFIER ** The following paragraphs are optional. Delete if not required. 6. Locks shall have a door position switch (DPS) to allow monitoring of the open/closed status of the door. 7. Locks shall have tri-color LED Status Indicator (L3): Green, Red, Yellow.

E. Electromagnetic Shear Locks, 2000 lb Holding Force: SDC 1561-1562 Series locks shall be mortise mounted and shall be provided with all required mounting hardware. Shear Lock design shall incorporate shear stops to prohibit horizontal shear motion. Units shall provide for both lateral and vertical field adjustment. Model 1562 shall be capable of being fit into 1-1/4 inch face frame. 1. Holding force shall be 2000 lbs. 2. Locks shall operate with 12 or 24VDC power input without field selection. Current required shall not exceed 650 mA @ 12VDC or 350 mA @ 24VDC.. 3. Locks shall incorporate automatic relock with 1 to 5 second delay relock timer, and shall include circuitry for voltage kickback suppression. 4. Locks shall be listed by Underwriters Laboratories as Auxiliary Locks (GWXT). 5. Finish: Satin Nickel Plated. ** NOTE TO SPECIFIER ** The following paragraphs are optional. Delete if not required. 6. Locks shall have a door position switch (DPS) to allow monitoring of the open/closed status of the door. 7. Locks shall have tri-color LED Status Indicator (L3): Green, Red, Yellow.

2.4 DELAYED EGRESS LOCKING SYSTEMS ** NOTE TO SPECIFIER ** The following describes various models of delayed egress locking systems. Delete all that are not required. If more than one type of system is required, give each a type designation and indicate type on Door Schedule.

A. Self-Contained Electromagnetic Delayed Egress Locking System, Visual/ Verbal Annunciation: SDC 101S, 101D, 101T Series locks shall be surface-mounted and include all necessary mounting hardware. Lock core shall not contain any epoxy-resin, and shall consist of steel laminations welded in a steel U-channel; all electronics enclosed within the housing; all exposed surfaces plated or anodized. Locks utilized on doors with mechanical latching hardware shall be activated by slight movement of the door and shall not require a switch input from the mechanical hardware for activation. Signage required for use of delayed egress shall be provided. 1. Holding force shall be 1650 lbs. 2. Locks shall have a digital display that visually indicates status and provides a countdown of seconds remaining until door release. Locks shall have an audio speaker; 85db minimum output; and shall generate verbal status and countdown messages. Speaker shall be an integral part of the delayed egress unit and shall not be accessible when the door is closed. 3. System shall have input for automatic release upon activation of the Fire Life Safety System; Request-to-Exit input; outputs for egress alarm and locked/ unlocked status; key switch for reset, momentary authorized egress and on-off. 4. Locks shall operate with 12 or 24VDC power input without field selection. Current required shall not exceed 820 mA @ 12VDC or 500 mA @ 24VDC for single lock and 1.5 Amp @ 12VDC or 850 mA @ 24VDC for double lock and tandem. 5. All field wiring connections shall be via on-board screw terminal connections. Magnetic lock shall contain printed-circuit board providing circuit and surge protection. 6. Locks shall be BHMA Certified Grade 1.

ELECTRICAL LOCKING SYSTEMS 08745 - 5 7. System shall be listed by Underwriters Laboratories (FWAX Special Locking Arrangements), and shall also be compliant with NFPA 101 Special Locking Arrangements, and UBC Special Egress Control Devices. 8. Double without Mullion. 9. Tandem for surface vertical rod or Mullion. ** NOTE TO SPECIFIER ** The following paragraphs apply to different jurisdictional requirements. Retain or delete as applicable. 10. NA NFPA, UFC, SBC, IBC, IFC Compliant Adj. 15 or 30 Second Exit Delay Adj. 0, 1, 2, 3 sec. nuisance delay Manual reset, built-in or remote 11. ND UBC, California Building Code NFPA, UFC, SBC, IBC, IFC Compliant 15 Second Exit Delay (Fixed) Adj. 0, 1, 2, sec. nuisance delay Manual reset, built-in or remote 12. NH NFPA, UFC, SBC, IBC, IFC Compliant 30 Second Exit Delay (Fixed) Adj. 0, 1, 2 sec. nuisance delay Manual reset, built-in or remote 13. BD BOCA Compliant 15 Second Exit Delay (Fixed) *Auto reset 30 seconds after door closure *45 sec. when AHJ approved 14. CD Chicago Building Code Compliant (Contains no moving parts) 15 Second Exit Delay (Fixed) 1-second nuisance delay Auto reset 30 seconds after door closure ** NOTE TO SPECIFIER ** The following paragraphs are optional. Delete if not required. 15. Locks shall have a door position switch (DPS) to allow monitoring of the open/closed status of the door. 16. Locks shall have a magnetic bond-sensor (BA) circuit to allow monitoring of the strength of the magnetic field between lock and armature. 17. Locks shall have an anti-tamper switch (ATS) to indicate an attempt to remove cover. 18. For doors without mechanical latching hardware, provide for each door a power transfer device (PT-2 armored loop or PTH-4 power transfer hinge) and Request- to-Exit Push Bar (PSB 560 Series Sure Exit). 19. Provide remote wall mount Reset Key Switch Assembly (702R-6) including key cylinder in accordance with requirements of Section 08710. 20. Provide remote wall mount Key Switch Assembly with dual function for Reset and Authorized Egress Bypass (707R-6) including key cylinder in accordance with requirements of Section 08710. 21. Provide remote wall mount Key Switch Assembly with dual function for Reset and System On/Off (708R-6) including key cylinder in accordance with requirements of Section 08710. 22. Provide remote wall mount Single Door Annunciator with audible alarm and tri- color LED (101-1A). 23. Provide remote wall mount Four Door Annunciator with audible alarm, mute button, and 4 tri-color LEDs (101-4AM). 24. Provide remote wall mount Single Door Annunciator/ Key Switch Assembly with dual function for Reset and System On/Off; audible alarm and tri-color LED (101- 1AK) including key cylinder in accordance with requirements of Section 08710

ELECTRICAL LOCKING SYSTEMS 08745 - 6 25. Provide remote wall mount Single Door Annunciator with tri-color LED and 3 push button switches for Momentary Access, System On/Off, and Alarm Mute (101-PAM). ** NOTE TO SPECIFIER ** Delete one or all of the following paragraphs as required. 26. Provide verbal annunciation in Spanish language. 27. Provide verbal annunciation in French language. ** NOTE TO SPECIFIER ** Delete the following paragraphs for finishes not required. 28. Case Finish: 628 Satin Aluminum, Clear Anodized 29. Case Finish: 313 Dark Bronze Anodized 30. Case Finish: 335 Black Duronodic 31. Case Finish: 605E Bright Brass Anodized 32. Case Finish: 606E Satin Brass Plated 33. Case Finish: 611E Bright Bronze Plated 34. Case Finish: 625E Bright Chromium Plated 35. Case Finish: 626E Satin Chromium Plated

B. Self-Contained Electromagnetic Delayed Egress Locking System, Visual/ Audio Annunciation: SDC 1511S, 1512D, 1511T Series locks shall be surface-mounted and include all necessary mounting hardware. Lock core shall not contain any epoxy-resin, and shall consist of steel laminations welded in a steel U-channel; all electronics enclosed within the housing; all exposed surfaces plated or anodized. Locks utilized on doors with mechanical latching hardware shall be activated by slight movement of the door and shall not require a switch input from the mechanical hardware for activation. Signage required for use of delayed egress shall be provided. 1. Holding force shall be 1650 lbs. 2. Locks shall have tri-color LED indicator to provide visual status of the system: Green indicates door secure, amber indicates release time-out operational and red indicates door unlocked. 3. System shall have an 85db audio tone output. Distinct tones shall provide pre- activation warning, unit activated alert and door unlocked condition. 4. System shall have input for automatic release upon activation of the Fire Life Safety System; Request-to-Exit input; outputs for egress alarm and locked/ unlocked status; key switch for reset, momentary authorized egress and on-off. 5. Locks shall operate with 12 or 24VDC power input without field selection. Current required shall not exceed 820 mA @ 12VDC or 500 mA @ 24VDC for single lock and 1.5 Amp @ 12VDC or 850 mA @ 24VDC for double lock and tandem. 6. All field wiring connections shall be via on-board screw terminal connections. Magnetic lock shall contain printed-circuit board providing circuit and surge protection. 7. Locks shall be BHMA Certified Grade 1. 8. System shall be listed by Underwriters Laboratories (FWAX Special Locking Arrangements), and shall also be compliant with NFPA 101 Special Locking Arrangements, and UBC Special Egress Control Devices. 9. Provide remote wall mount Reset Key Switch Assembly (702R-6) including key cylinder in accordance with requirements of Section 08710. 10. Provide remote wall mount Key Switch Assembly with dual function for Reset and Authorized Egress Bypass (707R-6) including key cylinder in accordance with requirements of Section 08710. 11. Provide remote wall mount Key Switch Assembly with dual function for Reset and System On/Off (708R-6) including key cylinder in accordance with requirements of Section 08710. 12. Provide remote wall mount Single Door Annunciator with audible alarm and tri- color LED (101-1A). 13. Provide remote wall mount Four Door Annunciator with audible alarm, mute button, and 4 tri-color LEDs (101-4AM).

ELECTRICAL LOCKING SYSTEMS 08745 - 7 14. Provide remote wall mount Single Door Annunciator/ Key Switch Assembly with dual function for Reset and System On/Off; audible alarm and tri-color LED (101- 1AK) including key cylinder in accordance with requirements of Section 08710 15. Provide remote wall mount Single Door Annunciator with tri-color LED and 3 push button switches for Momentary Access, System On/Off, and Alarm Mute (101-PAM). ** NOTE TO SPECIFIER ** The following paragraphs apply to different jurisdictional requirements. Retain or delete as applicable. 16. NA NFPA, UFC, SBC, IBC, IFC Compliant Adj. 15 or 30 Second Exit Delay Adj. 0, 1, 2, 3 sec. nuisance delay Manual reset, built-in or remote 17. ND UBC, California Building Code NFPA, UFC, SBC, IBC, IFC Compliant 15 Second Exit Delay (Fixed) Adj. 0, 1, 2, sec. nuisance delay Manual reset, built-in or remote 18. NH NFPA, UFC, SBC, IBC, IFC Compliant 30 Second Exit Delay (Fixed) Adj. 0, 1, 2 sec. nuisance delay Manual reset, built-in or remote 19. BD BOCA Compliant 15 Second Exit Delay (Fixed) *Auto reset 30 seconds after door closure *45 sec. when AHJ approved 20. CD Chicago Building Code Compliant (Contains no moving parts) 15 Second Exit Delay (Fixed) 1-second nuisance delay Auto reset 30 seconds after door closure ** NOTE TO SPECIFIER ** The following paragraphs are optional. Delete if not required. 21. Locks shall have a door position switch (DPS) to allow monitoring of the open/closed status of the door. 22. Locks shall have a magnetic bond-sensor (BA) circuit to allow monitoring of the strength of the magnetic field between lock and armature. 23. Locks shall have an anti-tamper switch (ATS) to indicate an attempt to remove cover. 24. For doors without mechanical latching hardware, provide for each door a power transfer device (PT-2 armored loop or PTH-4 power transfer hinge) and Request- to-Exit Push Bar (PSB 560 Series Sure Exit). ** NOTE TO SPECIFIER ** Delete the following paragraphs for finishes not required. 25. Case Finish: 628 Satin Aluminum, Clear Anodized 26. Case Finish: 313 Dark Bronze Anodized 27. Case Finish: 335 Black Duronodic 28. Case Finish: 605E Bright Brass Anodized 29. Case Finish: 606E Satin Brass Plated 30. Case Finish: 611E Bright Bronze Plated 31. Case Finish: 625E Bright Chromium Plated 32. Case Finish: 626E Satin Chromium Plated

C. Self-contained Electromagnetic Delayed Egress Locking System, Visual/Audio Annunciation : SDC 1581SND – 1581SBD Series locks shall be surface mounted and include all necessary mounting hardware. Core shall not contain any epoxy-resin, and consist of steel laminations welded in a steel U-channel. The winding and electronics to be contained within the aluminum housing and be replaceable without removing the lock from the door frame. Size 10”L x 2” H x 2-3/8” D 1. Holding force shall be 650 lbs.

ELECTRICAL LOCKING SYSTEMS 08745 - 8 2. Locks shall have tri-color LED indicator to provide visual status of the system. Green indicates door secure, amber indicates release time- out operationall and Red indicates door unlocked. 3. System shall have an 85db audio tone output. Distinct tones shall provide pre- activation warning, until activated alert and door unlocked condition. 4. All field wiring connections shall be via on-board screw terminal connections. Magnetic lock shall contain printed-circuit board providing circuit and surge protection. 5. Locks shall operate with 12 or 24VDC power input with out field selection. 6. Locks shall be BHMA Certified Grade 1 ranking. Provide 2 locks for pairs of doors. 7. Locks shall be listed by Underwriters Laboratories as Auxiliary Locks (FWAX 8. Special Locking Arrangements, and shall also be compliant with NFPA 101 Special Locking Arrangements, and UBC Special Egress Control Devices. ** NOTE TO SPECIFIER ** The following paragraphs are optional. Delete if not required. 9. Locks shall have a door position switch (D) to allow monitoring of the open/closed status of the door. 10. Locks shall have a magnetic bond-sensor (B) circuit to allow monitoring of the strength of the magnetic field between lock and armature. 11. Locks shall have tri-color LED Status Indicator (L3): Green, Red, Yellow. 12. Pairs of Doors Without Mullion: provide 2 locks 13. Provide SND option. UBC, NFPA 101 , NFPA 1, UFC, IBC, IFC, and California Building Ccde Compliant. 15 sec. exit dela,1 sec. nuisance delay Station control required for lock reset following unauthorized egress. Field selectable automatic or manual power-up after power outage and fire emergency release. Manual power-up is a UBC and California State requirement. 14 Provide SBD option. BOCA and Chicago Building Code Compliant 15 sec. delay, 1 sec. nuisance delay Automatically resets and locks 30 seconds after door closure Reset station control not required 15 Provide 928 EntryCheck Digital Keypad Reset/Manual Power Up, Momentary or Sustained Bypass. 16 Provide 728 Key switch, 2 Keys. Reset / Manual Power Up/ Sustained Bypass 17 Provide 728L Key Switch, 2 Keys. LED Reset / Manual Power Up / Sustained Bypass. 18. Provide 702R-6 Key switch assembly, less cylinder. Reset / Manual Power Up. 19. Provide 101-1AKKey Switch assembly, 2 gang, LED, audible alarm, less cylinder 20. Reset / Manual Power Up/ Sustained Bypass. 21. Provide 101-1A Single station annunciator is equipped with a tri-color LED and audible alarm. 22. Provide 101-PAM Visual and audible annunciation, momentary & sustained bypass, and audible mute. 23. Provide 101-4AM Visual and audible annunciation with audible mute for up to four openings. 24. Provide CC-3 Cable kit for connecting two locks through the header. 25. Provide CC-10 Cable kit for connecting wiring for two locks in a junction box. 26. Provide PSB560V Sure Exit Push Bar Aluminum Anodized 27. Provide PSB560X Sure Exit Push Bar Dark Bronze Anodized 28. Provide PSB560Y Sure Exit Push Bar Black Anodized 29. Provide PT-2U Stainless Surface Mount Power Transfer Loops 30. Provide PT-2B Black Surface Mount Power Transfer loops 31. Provide PT-3V Aluminum Termination Box

ELECTRICAL LOCKING SYSTEMS 08745 - 9 32. Provide PTH-4Q Four Wire Electric Power Transfer Hinge 4.5 x 4.5 Dull Chrome 33. Case Finish: 628 Satin Aluminum, Clear Anodized 34. Case Finish: 313 Dark Bronze Anodized 35. Case Finish: 335 Black Duronodic 36. Case Finish: 605E Bright Brass Anodized 37. Case Finish: 606E Satin Brass Plated 38. Case Finish: 611E Bright Bronze Plated 39. Case Finish: 625E Bright Chromium Plated 40. Case Finish: 626E Satin Chromium Plated

D. Modular Electromagnetic Delayed Egress Locking System, Visual/ Verbal Annunciation: SDC 101V71S-101V85T Series shall consist of a delayed egress control module and an electromagnetic lock. The control module shall be packaged on a two gang wall plate suitable for recessed or surface mounting and be equipped with anti-tamper switch. Electromagnetic lock shall be surface-mounted and include all necessary mounting hardware. Lock core shall not contain any epoxy-resin, and consist of steel laminations welded in a steel U-Channel. The winding and electronics to be contained within the aluminum housing and be replaceable without removing the lock from the doorframe. Locks utilized on doors with mechanical latching hardware shall be activated by slight movement of the door and shall not require a switch input from the mechanical hardware for activation. Signage required for use of delayed egress shall be provided. 1. Lock holding force shall be 1200 lbs.; BHMA Certified Grade 2 ranking. 2. Locks shall operate on 12 or 24VDC without field selection.. Current required shall not exceed 470 mA @ 12VDC or 350 mA @ 24VDC for single lock and 720 mA @ 12VDC or 470 mA @ 24VDC for double lock. 3. All field wiring connections shall be via on-board screw terminal connections. Magnetic lock shall contain printed-circuit board providing circuit and surge protection. 4. Control Module shall have a digital display that visually indicates status and provides a countdown of seconds remaining until door release. Control Module shall have an audio speaker; 85db minimum output; and shall generate verbal status and countdown messages. 5. System shall have input for automatic release upon activation of the Fire Life Safety System; Request-to-Exit input; outputs for egress alarm and locked/ unlocked status; key switch for reset, momentary authorized egress and on-off. 6. System shall be listed by Underwriters Laboratories (FWAX Special Locking Arrangements), and shall also be compliant with NFPA 101 Special Locking Arrangements, and UBC Special Egress Control Devices. ** NOTE TO SPECIFIER ** The following paragraphs apply to different jurisdictional requirements. Retain or delete as applicable. 7. NA NFPA, UFC, SBC, IBC, IFC Compliant Adj. 15 or 30 Second Exit Delay Adj. 0, 1, 2, 3 sec. nuisance delay Manual reset, built-in or remote 8. ND UBC, California Building Code NFPA, UFC, SBC, IBC, IFC Compliant 15 Second Exit Delay (Fixed) Adj. 0, 1, 2, sec. nuisance delay Manual reset, built-in or remote 9. NH NFPA, UFC, SBC, IBC, IFC Compliant 30 Second Exit Delay (Fixed) Adj. 0, 1, 2 sec. nuisance delay Manual reset, built-in or remote 10. BD BOCA Compliant 15 Second Exit Delay (Fixed) *Auto reset 30 seconds after door closure

ELECTRICAL LOCKING SYSTEMS 08745 - 10 *45 sec. when AHJ approved 11. CD Chicago Building Code Compliant (Contains no moving parts) 15 Second Exit Delay (Fixed) 1-second nuisance delay Auto reset 30 seconds after door closure ** NOTE TO SPECIFIER ** The following paragraphs are optional. Delete if not required. 12. Locks shall have a door position switch (DPS) to allow monitoring of the open/closed status of the door. 13. Locks shall have a magnetic bond-sensor (BA) circuit to allow monitoring of the strength of the magnetic field between lock and armature. 14. Locks shall have an anti-tamper switch (ATS) to indicate an attempt to remove cover. 15. For doors without mechanical latching hardware, provide for each door a power transfer device (PT-2 armored loop or PTH-4 power transfer hinge) and Request- to-Exit Push Bar (PSB 560 Series Sure Exit). 16. Provide plastic box (SB2) for surface mounting of Control Module. 17. Provide remote wall mount Reset Key Switch Assembly (702R-6) including key cylinder in accordance with requirements of Section 08710. 18. Provide remote wall mount Key Switch Assembly with dual function for Reset and Authorized Egress Bypass (707R-6) including key cylinder in accordance with requirements of Section 08710. 19. Provide remote wall mount Key Switch Assembly with dual function for Reset and System On/Off (708R-6) including key cylinder in accordance with requirements of Section 08710. 20. Provide remote wall mount Single Door Annunciator with audible alarm and tri- color LED (101-1A). 21. Provide remote wall mount Four Door Annunciator with audible alarm, mute button, and 4 tri-color LEDs (101-4AM). 22. Provide remote wall mount Single Door Annunciator/ Key Switch Assembly with dual function for Reset and System On/Off; audible alarm and tri-color LED (101- 1AK) including key cylinder in accordance with requirements of Section 08710 23. Provide remote wall mount Single Door Annunciator with tri-color LED and 3 push button switches for Momentary Access, System On/Off, and Alarm Mute (101-PAM). ** NOTE TO SPECIFIER ** Delete one or all of the following paragraphs as required. 24. Provide verbal annunciation in Spanish language. 25. Provide verbal annunciation in French language. ** NOTE TO SPECIFIER ** Delete the following paragraphs for finishes not required. 26. Case Finish: 628 Satin Aluminum, Clear Anodized 27. Case Finish: 313 Dark Bronze Anodized 28. Case Finish: 335 Black Duronodic 29. Case Finish: 605E Bright Brass Anodized 30. Case Finish: 606E Satin Brass Plated 31. Case Finish: 611E Bright Bronze Plated 32. Case Finish: 625E Bright Chromium Plated 33. Case Finish: 626E Satin Chromium Plated

E. Modular Electromagnetic Delayed Egress Locking System, Visual/ Verbal Annunciation: SDC 101V85S- 101V85T Series shall consist of a delayed egress control module and an electromagnetic lock. The control module shall be packaged on a two gang wall plate suitable for recessed or surface mounting and be equipped with anti-tamper switch. Electromagnetic lock shall be surface-mounted and include all necessary mounting hardware. Lock core shall not contain any epoxy-resin, and consist of steel laminations welded in a steel U-Channel. The winding and electronics to be contained within the aluminum housing and be replaceable without removing the lock from the door frame. Locks utilized on doors with mechanical latching hardware shall be activated by slight

ELECTRICAL LOCKING SYSTEMS 08745 - 11 movement of the door and shall not require a switch input from the mechanical hardware for activation. Signage required for use of delayed egress shall be provided. 1. Lock holding force shall be 650 lbs.; BHMA Certified Grade 3 ranking. 2. Locks shall operate on 12 or 24VDC without field selection.. Current required shall not exceed 660 mA @ 12VDC or 440 mA @ 24VDC for single lock and 1100 mA @ 12VDC or 660 mA @ 24VDC for double lock. 3. All field wiring connections shall be via on-board screw terminal connections. Magnetic lock shall contain printed-circuit board providing circuit and surge protection. 4. Control Module shall have a digital display that visually indicates status and provides a countdown of seconds remaining until door release. Control Module shall have an audio speaker; 85db minimum output; and shall generate verbal status and countdown messages. 5. System shall have input for automatic release upon activation of the Fire Life Safety System; Request-to-Exit input; outputs for egress alarm and locked/ unlocked status; key switch for reset, momentary authorized egress and on-off. 6. System shall be listed by Underwriters Laboratories (FWAX Special Locking Arrangements), and shall also be compliant with NFPA 101 Special Locking Arrangements, and UBC Special Egress Control Devices. ** NOTE TO SPECIFIER ** The following paragraphs apply to different jurisdictional requirements. Retain or delete as applicable. 7. NA NFPA, UFC, SBC, IBC, IFC Compliant Adj. 15 or 30 Second Exit Delay Adj. 0, 1, 2, 3 sec. nuisance delay Manual reset, built-in or remote 8. ND UBC, California Building Code NFPA, UFC, SBC, IBC, IFC Compliant 15 Second Exit Delay (Fixed) Adj. 0, 1, 2, sec. nuisance delay Manual reset, built-in or remote 9. NH NFPA, UFC, SBC, IBC, IFC Compliant 30 Second Exit Delay (Fixed) Adj. 0, 1, 2 sec. nuisance delay Manual reset, built-in or remote 10. BD BOCA Compliant 15 Second Exit Delay (Fixed) *Auto reset 30 seconds after door closure *45 sec. when AHJ approved 11. CD Chicago Building Code Compliant (Contains no moving parts) 15 Second Exit Delay (Fixed) 1-second nuisance delay Auto reset 30 seconds after door closure ** NOTE TO SPECIFIER ** The following paragraphs are optional. Delete if not required. 12. Locks shall have a door position switch (DPS) to allow monitoring of the open/closed status of the door. 13. Locks shall have a magnetic bond-sensor (BA) circuit to allow monitoring of the strength of the magnetic field between lock and armature. 14. Locks shall have an anti-tamper switch (ATS) to indicate an attempt to remove cover. 15. For doors without mechanical latching hardware, provide for each door a power transfer device (PT-2 armored loop or PTH-4 power transfer hinge) and Request- to-Exit Push Bar (PSB 560 Series Sure Exit). 16. Provide plastic box (SB2) for surface mounting of Control Module. 17. Provide remote wall mount Reset Key Switch Assembly (702R-6) including key cylinder in accordance with requirements of Section 08710.

ELECTRICAL LOCKING SYSTEMS 08745 - 12 18. Provide remote wall mount Key Switch Assembly with dual function for Reset and Authorized Egress Bypass (707R-6) including key cylinder in accordance with requirements of Section 08710. 19. Provide remote wall mount Key Switch Assembly with dual function for Reset and System On/Off (708R-6) including key cylinder in accordance with requirements of Section 08710. 20. Provide remote wall mount Single Door Annunciator with audible alarm and tri- color LED (101-1A). 21. Provide remote wall mount Four Door Annunciator with audible alarm, mute button, and 4 tri-color LEDs (101-4AM). 22. Provide remote wall mount Single Door Annunciator/ Key Switch Assembly with dual function for Reset and System On/Off; audible alarm and tri-color LED (101- 1AK) including key cylinder in accordance with requirements of Section 08710 23. Provide remote wall mount Single Door Annunciator with tri-color LED and 3 push button switches for Momentary Access, System On/Off, and Alarm Mute (101-PAM). ** NOTE TO SPECIFIER ** Delete one or all of the following paragraphs as required. 24. Provide verbal annunciation in Spanish language. 25. Provide verbal annunciation in French language. ** NOTE TO SPECIFIER ** Delete the following paragraphs for finishes not required. 26. Case Finish: 628 Satin Aluminum, Clear Anodized 27. Case Finish: 313 Dark Bronze Anodized 28. Case Finish: 335 Black Duronodic 29. Case Finish: 605E Bright Brass Anodized 30. Case Finish: 606E Satin Brass Plated 31. Case Finish: 611E Bright Bronze Plated 32. Case Finish: 625E Bright Chromium Plated 33. Case Finish: 626E Satin Chromium Plated

F. Modular Electromagnetic Delayed Egress Locking System, Visual/ Audio Annunciation: SDC 101A71S- 101A71T Series shall consist of a delayed egress control module and an electromagnetic lock. The control module shall be packaged on a two gang wall plate suitable for recessed or surface mounting and be equipped with anti-tamper switch. Electromagnetic lock shall be surface-mounted and include all necessary mounting hardware. Lock core shall not contain any epoxy-resin, and consist of steel laminations welded in a steel U-Channel. The winding and electronics to be contained within the aluminum housing and be replaceable without removing the lock from the door frame. Locks utilized on doors with mechanical latching hardware shall be activated by slight movement of the door and shall not require a switch input from the mechanical hardware for activation. Signage required for use of delayed egress shall be provided. 1. Lock holding force shall be 1200 lbs.; BHMA Certified Grade 2 ranking. 2. Lock shall operate on 12 or 24VDC without field selection. Current required shall not exceed 400 mA @ 12VDC or 275 mA @ 24VDC for single lock and 650 mA @ 12VDC or 400 mA @ 24VDC for double lock. 3. All field wiring connections shall be via on-board screw terminal connections. Magnetic lock shall contain printed-circuit board providing circuit and surge protection. 4. Control Module shall have tri-color LED indicator to provide visual status of the system: Green indicates door secure, amber indicates release time-out operational and red indicates door unlocked. Control Module shall have an audio speaker; 85db minimum output; and shall generate distinct tones indicating pre- activation warning, unit activated alert and door unlocked condition 5. System shall have input for automatic release upon activation of the Fire Life Safety System; Request-to-Exit input; outputs for egress alarm and locked/ unlocked status; key switch for reset, momentary authorized egress and on-off.

ELECTRICAL LOCKING SYSTEMS 08745 - 13 6. System shall be listed by Underwriters Laboratories (FWAX Special Locking Arrangements), and shall also be compliant with NFPA 101 Special Locking Arrangements, and UBC Special Egress Control Devices. ** NOTE TO SPECIFIER ** The following paragraphs apply to different jurisdictional requirements. Retain or delete as applicable. 7. NA NFPA, UFC, SBC, IBC, IFC Compliant Adj. 15 or 30 Second Exit Delay Adj. 0, 1, 2, 3 sec. nuisance delay Manual reset, built-in or remote 8. ND UBC, California Building Code NFPA, UFC, SBC, IBC, IFC Compliant 15 Second Exit Delay (Fixed) Adj. 0, 1, 2, sec. nuisance delay Manual reset, built-in or remote 9. NH NFPA, UFC, SBC, IBC, IFC Compliant 30 Second Exit Delay (Fixed) Adj. 0, 1, 2 sec. nuisance delay Manual reset, built-in or remote 10. BD BOCA Compliant 15 Second Exit Delay (Fixed) *Auto reset 30 seconds after door closure *45 sec. when AHJ approved 11. CD Chicago Building Code Compliant (Contains no moving parts) 15 Second Exit Delay (Fixed) 1-second nuisance delay Auto reset 30 seconds after door closure ** NOTE TO SPECIFIER ** The following paragraphs are optional. Delete if not required. 12. Locks shall have a door position switch (DPS) to allow monitoring of the open/closed status of the door. 13. Locks shall have a magnetic bond-sensor (BA) circuit to allow monitoring of the strength of the magnetic field between lock and armature. 14. Locks shall have an anti-tamper switch (ATS) to indicate an attempt to remove cover. 15. For doors without mechanical latching hardware, provide for each door a power transfer device (PT-2 armored loop or PTH-4 power transfer hinge) and Request- to-Exit Push Bar (PSB 560 Series Sure Exit). 16. Provide plastic box (SB2) for surface mounting of Control Module. 17. Provide remote wall mount Reset Key Switch Assembly (702R-6) including key cylinder in accordance with requirements of Section 08710. 18. Provide remote wall mount Key Switch Assembly with dual function for Reset and Authorized Egress Bypass (707R-6) including key cylinder in accordance with requirements of Section 08710. 19. Provide remote wall mount Key Switch Assembly with dual function for Reset and System On/Off (708R-6) including key cylinder in accordance with requirements of Section 08710. 20. Provide remote wall mount Single Door Annunciator with audible alarm and tri- color LED (101-1A). 21. Provide remote wall mount Four Door Annunciator with audible alarm, mute button, and 4 tri-color LEDs (101-4AM). 22. Provide remote wall mount Single Door Annunciator/ Key Switch Assembly with dual function for Reset and System On/Off; audible alarm and tri-color LED (101- 1AK) including key cylinder in accordance with requirements of Section 08710 23. Provide remote wall mount Single Door Annunciator with tri-color LED and 3 push button switches for Momentary Access, System On/Off, and Alarm Mute (101-PAM).

ELECTRICAL LOCKING SYSTEMS 08745 - 14 ** NOTE TO SPECIFIER ** Delete the following paragraphs for finishes not required. 24. Case Finish: 628 Satin Aluminum, Clear Anodized 25. Case Finish: 313 Dark Bronze Anodized 26. Case Finish: 335 Black Duronodic 27. Case Finish: 605E Bright Brass Anodized 28. Case Finish: 606E Satin Brass Plated 29. Case Finish: 611E Bright Bronze Plated 30. Case Finish: 625E Bright Chromium Plated 31. Case Finish: 626E Satin Chromium Plated

G. Modular Electromagnetic Delayed Egress Locking System, Visual/ Audio Annunciation: SDC 101A85S – 101A85T Series shall consist of a delayed egress control module and an electromagnetic lock. The control module shall be packaged on a two gang wall plate suitable for recessed or surface mounting and be equipped with anti-tamper switch. Electromagnetic lock shall be surface-mounted and include all necessary mounting hardware. Lock core shall not contain any epoxy-resin, and consist of steel laminations welded in a steel U-Channel. The winding and electronics to be contained within the aluminum housing and be replaceable without removing the lock from the door frame. Locks utilized on doors with mechanical latching hardware shall be activated by slight movement of the door and shall not require a switch input from the mechanical hardware for activation. Signage required for use of delayed egress shall be provided. 1. Lock holding force shall be 650 lbs.; BHMA Certified Grade 3 ranking. 2. Locks to operate on 12 or 24VDC without field selection.. Current required shall not exceed 590 mA @ 12VDC or 370 mA @ 24VDC for single lock and 1030 mA @ 12VDC or 590 mA @ 24VDC for double lock. 3. All field wiring connections shall be via on-board screw terminal connections. Magnetic lock shall contain printed-circuit board providing circuit and surge protection. 4. Control Module shall have tri-color LED indicator to provide visual status of the system: Green indicates door secure, amber indicates release time-out operational and red indicates door unlocked. Control Module shall have an audio speaker; 85db minimum output; and shall generate distinct tones indicating pre- activation warning, unit activated alert and door unlocked condition 5. System shall have input for automatic release upon activation of the Fire Life Safety System; Request-to-Exit input; outputs for egress alarm and locked/ unlocked status; key switch for reset, momentary authorized egress and on-off. 6. System shall be listed by Underwriters Laboratories (FWAX Special Locking Arrangements), and shall also be compliant with NFPA 101 Special Locking Arrangements, and UBC Special Egress Control Devices. ** NOTE TO SPECIFIER ** The following paragraphs apply to different jurisdictional requirements. Retain or delete as applicable. 7. NA NFPA, UFC, SBC, IBC, IFC Compliant Adj. 15 or 30 Second Exit Delay Adj. 0, 1, 2, 3 sec. nuisance delay Manual reset, built-in or remote 8. ND UBC, California Building Code NFPA, UFC, SBC, IBC, IFC Compliant 15 Second Exit Delay (Fixed) Adj. 0, 1, 2, sec. nuisance delay Manual reset, built-in or remote 9. NH NFPA, UFC, SBC, IBC, IFC Compliant 30 Second Exit Delay (Fixed) Adj. 0, 1, 2 sec. nuisance delay Manual reset, built-in or remote 10. BD BOCA Compliant 15 Second Exit Delay (Fixed)

ELECTRICAL LOCKING SYSTEMS 08745 - 15 *Auto reset 30 seconds after door closure *45 sec. when AHJ approved 11. CD Chicago Building Code Compliant (Contains no moving parts) 15 Second Exit Delay (Fixed) 1-second nuisance delay Auto reset 30 seconds after door closure ** NOTE TO SPECIFIER ** The following paragraphs are optional. Delete if not required. 12. Locks shall have a door position switch (DPS) to allow monitoring of the open/closed status of the door. 13. Locks shall have a magnetic bond-sensor (BA) circuit to allow monitoring of the strength of the magnetic field between lock and armature. 14. For doors without mechanical latching hardware, provide for each door a power transfer device (PT-2 armored loop or PTH-4 power transfer hinge) and Request- to-Exit Push Bar (PSB 560 Series Sure Exit). 15. Provide plastic box (SB2) for surface mounting of Control Module. 16. Provide remote wall mount Reset Key Switch Assembly (702R-6) including key cylinder in accordance with requirements of Section 08710. 17. Provide remote wall mount Key Switch Assembly with dual function for Reset and Authorized Egress Bypass (707R-6) including key cylinder in accordance with requirements of Section 08710. 18. Provide remote wall mount Key Switch Assembly with dual function for Reset and System On/Off (708R-6) including key cylinder in accordance with requirements of Section 08710. 19. Provide remote wall mount Single Door Annunciator with audible alarm and tri- color LED (101-1A). 20. Provide remote wall mount Four Door Annunciator with audible alarm, mute button, and 4 tri-color LEDs (101-4AM). 21. Provide remote wall mount Single Door Annunciator/ Key Switch Assembly with dual function for Reset and System On/Off; audible alarm and tri-color LED (101- 1AK) including key cylinder in accordance with requirements of Section 08710 22. Provide remote wall mount Single Door Annunciator with tri-color LED and 3 push button switches for Momentary Access, System On/Off, and Alarm Mute (101-PAM). ** NOTE TO SPECIFIER ** Delete the following paragraphs for finishes not required. 23. Case Finish: 628 Satin Aluminum, Clear Anodized 24. Case Finish: 313 Dark Bronze Anodized 25. Case Finish: 335 Black Duronodic 26. Case Finish: 605E Bright Brass Anodized 27. Case Finish: 606E Satin Brass Plated 28. Case Finish: 611E Bright Bronze Plated 29. Case Finish: 625E Bright Chromium Plated 30. Case Finish: 626E Satin Chromium Plated 31. ** NOTE TO SPECIFIER ** The following describes various models of delayed egress exit devices. Delete all that are not required. If more than one type is required, give each a type designation and indicate type on Door Schedule.

2.5 ELECTRIFIED MORTISE AND CYLINDRICAL LOCKS ** NOTE TO SPECIFIER ** The following describes various models of electrified locks. Delete all types not required. If more than one type is required, give each a type designation and indicate type on Door Schedule.

A. Mortise Locks with Electric Frame-Mounted Actuators: SDC HiTower® 7500 Series shall consist of a heavy-duty mortise lock, with vandal resistant clutch trim, and electric frame mounted actuator providing locking/ unlocking functions without unlatching the door. Actuator mounts in hollow metal frame; no wiring through the door; all wiring in the door

ELECTRICAL LOCKING SYSTEMS 08745 - 16 frame. BHMA Grade 1. UL listed 3 hour “A” label. Latch bolt throw:3/4 inch. Supplied less cylinder 1. Fail-safe actuators available for 1-1/4 to 2 inch face frame. 2. Fail-secure actuators available for 2 inch face frame. ** NOTE TO SPECIFIER ** The following paragraphs apply to different lock functions. Retain or delete as applicable. 3. Model Z7530: Fail-Safe, Inside and Outside Locked; Unlocked by access control, remote control, and key from either side. 4. Model Z7540: Fail-Safe, Outside Locked Only; Unlocked by access control, remote control, and inside lever. 5. Model Z7550: Fail-Safe, Outside Locked Only; Unlocked by access control, remote control, outside key, and inside lever. 6. Model Z7560: Fail-Secure, Inside and Outside Locked; Unlocked by access control, remote control, and key from either side. 7. Model Z7570: Fail- Secure, Outside Locked Only; Unlocked by access control, remote control, outside key, and inside lever. ** NOTE TO SPECIFIER ** Delete voltage not required. 8. Voltage: 115VAC 0.2 Amp. 9. Voltage: 24VAC 0.5 Amp. 10. Voltage: 24VDC 0.5 Amp. ** NOTE TO SPECIFIER ** The following paragraphs are optional. Delete if not required. 11. Provide latch status switch (9A) to indicate door is latched. 12. Provide latch and deadlock status switch (69A) to indicate door is latched and locked. 13. Provide socket connector (SC-10) with 10 foot cable. ** NOTE TO SPECIFIER ** Delete the following paragraphs for finishes not required. 14. Finish: BHMA 605: Bright brass, clear coated. 15. Finish: BHMA 606: Satin brass, clear coated. 16. Finish: BHMA 611: Bright bronze, clear coated. 17. Finish: BHMA 612: Satin bronze, clear coated. 18. Finish: BHMA 613: Dark-oxidized satin bronze, oil rubbed. 19. Finish: BHMA 625: Bright chromium plated. 20. Finish: BHMA 626: Satin chromium plated. 21. Finish: BHMA 627: Satin aluminum, clear coated. 22. Finish: BHMA 629: Bright stainless steel. 23. Finish: BHMA 630: Satin stainless steel.

B. Electrified Mortise Locks: SDC SELECTRIC PRO 7800 Series shall consist of a heavy- duty electrified mortise lock providing locking/ unlocking functions without unlatching the door. Vandal resistant clutch lever permits outside lever to operate without retracting the latch when locked. Field selectable, mode, function, voltage, and hand. BHMA Grade 1. UL listed 3 hour “A” label; 3/4 inch latch bolt throw; supplied less Cylinder. ** NOTE TO SPECIFIER ** The following paragraphs apply to different lock functions. Retain or delete as applicable. 1. Model Z7830: Fail-Safe, Inside and Outside Locked; Unlocked by access control, remote control, and key from either side. 2. Model Z7850: Fail-Safe, Outside Locked Only; Unlocked by access control, remote control, outside key, and inside lever. 3. Model Z7832: Fail-Secure, Inside and Outside Locked; Unlocked by access control, remote control, and key from either side. 4. Model Z7852: Fail- Secure, Outside Locked Only; Unlocked by access control, remote control, outside key, and inside lever. ** NOTE TO SPECIFIER ** Delete voltage not required. 5. Voltage: 12VDC @ 0.9 Amp. 6. Voltage: 24VDC @ 0.5 Amp. ** NOTE TO SPECIFIER ** The following paragraphs are optional. Delete if not required.

ELECTRICAL LOCKING SYSTEMS 08745 - 17 7. Provide internal request-to-exit (R) SPDT Switch 8. Provide latch and deadlock status switch (L) to indicate door is latched and locked. 9. Provide SPDT door position switch to indicate door open or closed. 10. Provide cable and connector: a. CC105 5’ Cable for locks without optimal outputs b. CC105 5’ Cable for locks with optimal outputs ** NOTE TO SPECIFIER ** Delete the following paragraphs for finishes not required. 11. Finish: BHMA 605: Bright brass, clear coated. 12. Finish: BHMA 606: Satin brass, clear coated. 13. Finish: BHMA 611: Bright bronze, clear coated. 14. Finish: BHMA 612: Satin bronze, clear coated. 15. Finish: BHMA 613: Dark-oxidized satin bronze, oil rubbed. 16. Finish: BHMA 625: Bright chromium plated. 17. Finish: BHMA 626: Satin chromium plated. 18. Finish: BHMA 629: Bright stainless steel. 19. Finish: BHMA 630: Satin stainless steel.

C. Electrified Cylindrical Locks: SDC HiTower® 7200/7300 Series shall consist of a heavy- duty electrified lock providing locking/ unlocking functions without unlatching the door. Vandal resistant clutch lever release with power return spring mechanism. BHMA Grade 1. UL listed 3 hour “A” label. 1. Latch bolt throw: 9/16 inch. Provide 3/4 inch bolt at pairs of rated doors. 2. Voltage: 24VDC @ 200 mA. ** NOTE TO SPECIFIER ** The following paragraphs apply to different lock functions. Retain or delete as applicable. 3. Model ZA7250: Cylindrical Lock, Fail-Safe, Outside Locked Only; Unlocked by access control, remote control, outside key, and inside lever. 4. Model ZA7260: Cylindrical Lock, Fail- Secure, Outside Locked Only; Unlocked by access control, remote control, outside key, and inside lever. ** NOTE TO SPECIFIER ** The following paragraphs are optional. Delete if not required. 5. Provide internal request-to-exit (REX) switch. ** NOTE TO SPECIFIER ** Delete the following paragraphs for finishes not required. 6. Finish: BHMA 605: Bright brass, clear coated. 7. Finish: BHMA 606: Satin brass, clear coated. 8. Finish: BHMA 612: Satin bronze, clear coated. 9. Finish: BHMA 613: Dark-oxidized satin bronze, oil rubbed. 10. Finish: BHMA 625: Bright chromium plated. 11. Finish: BHMA 626: Satin chromium plated.

2.6 ELECTRIC BOLT LOCKS ** NOTE TO SPECIFIER ** The following describes various models of electric bolt locks. Delete all types not required. If more than one type is required, give each a type designation and indicate type on Door Schedule.

A. Mortise Direct Throw Type: SDC 100/ 200 Series electric bolt lock. Continuous duty solenoid; Requires 5 inch depth; Non-handed; Mortise strike. ** NOTE TO SPECIFIER ** Delete models not required. 1. Model 110: Fail-safe; 2-3/4 x 1-1/4 inch faceplate. 2. Model 160A: Fail-safe; Auto Relock Switch; 4-7/8 x 1-1/4 inch faceplate. 3. Model 210: Fail- secure; 2-3/4 x 1-1/4 inch faceplate. 4. Model 260:A Fail- secure; Auto Relock Switch; 4-7/8 x 1-1/4 inch faceplate. ** NOTE TO SPECIFIER ** Delete voltage not required. 5. Voltage: 12VDC @ 0.9 Amp. Failsafe. 12VDC @ 1Amp Failsecure. 6. Voltage: 24VDC @ 0.5 Amp. Failsafe. 24VDC @ 0.5 Amp Failsecure. 7. Voltage: 24VAC @ 0.5 Amp. 24VAC @ 0.5 Amp Failsecure.

ELECTRICAL LOCKING SYSTEMS 08745 - 18 ** NOTE TO SPECIFIER ** The following paragraphs are optional. Delete if not required. 8. Provide wood frame back box (100EB) for 160/ 260 Series. ** NOTE TO SPECIFIER ** Delete the following paragraphs for finishes not required. 9. Finish: BHMA 605: Bright brass, clear coated. 10. Finish: BHMA 606: Satin brass, clear coated. 11. Finish: BHMA 611: Bright bronze, clear coated. 12. Finish: BHMA 612: Satin bronze, clear coated. 13. Finish: BHMA 613: Dark-oxidized satin bronze, oil rubbed. 14. Finish: BHMA 625: Bright chromium plated. 15. Finish: BHMA 626: Satin chromium plated. 16. Finish: BHMA 628: Satin aluminum, clear anodized. 17. Finish: BHMA 630: Satin stainless steel. 18. Finish: BHMA 313: Dark-oxidized satin bronze anodized. 19. Finish: BHMA 335: Flat black anodized.

B. Narrow Mortise Type: SDC 1091/ 1291/ 1490/ 2490/ FS23M Spacesaver Series electric bolt lock. Continuous duty solenoid; Requires 1-5/8 inch depth; Non-handed; Mortise strike; Auto Relock Switch. 1. Dimensions: 8 inches (L) x 1-1/2 inches (W) x 1-5/8 inches (D). ** NOTE TO SPECIFIER ** Delete models not required. 2. Model 1091: Fail-safe; Less Auto Relock Switch. 3. Model 1091A: Fail-safe. 4. Model 1091ADL: Fail-safe; Deadlocking. 5. Model 1291A: Fail-secure. 6. Model 1490A: Fail-safe; fits 1-1/2 inch frame. 7. Model 2490A: Fail-secure; fits 1-1/2 inch frame. 8. Model FS23M: Dual Fail-safe. ** NOTE TO SPECIFIER ** Delete voltage not required. 9. Voltage: 12VDC @ 0.9 Amp. Failsafe. 12VDC @ 1Amp Failsecure. 10. Voltage: 24VDC @ 0.5 Amp. Failsafe. 24VDC @ 0.5 Amp Failsecure. 11. Voltage: 24VAC @ 0.5 Amp. 24VAC @ 0.5 Amp Failsecure. ** NOTE TO SPECIFIER ** The following paragraphs are optional. Delete if not required. 12. Provide wood frame back box (1000EB) for 1091A/ FS23M Series. ** NOTE TO SPECIFIER ** Delete the following paragraphs for finishes not required. 13. Finish: BHMA 605: Bright brass, clear coated. 14. Finish: BHMA 606: Satin brass, clear coated. 15. Finish: BHMA 611: Bright bronze, clear coated. 16. Finish: BHMA 612: Satin bronze, clear coated. 17. Finish: BHMA 613: Dark-oxidized satin bronze, oil rubbed. 18. Finish: BHMA 625: Bright chromium plated. 19. Finish: BHMA 626: Satin chromium plated. 20. Finish: BHMA 628: Satin aluminum, clear anodized. 21. Finish: BHMA 630: Satin stainless steel. 22. Finish: BHMA 313: Dark-oxidized satin bronze anodized. 23. Finish: BHMA 335: Flat black anodized.

C. Heavy Duty Narrow Mortise Type: SDC 1190/ 2090 Spacesaver Series electric bolt lock. Continuous duty solenoid; 3/4 inch diameter bolt; 3/4 inch throw; Requires 1-5/8 inch depth; Mortise strike; Auto Relock Switch. 1. Dimensions: 8 inches (L) x 1-1/2 inches (W) x 1-5/8 inches (D). ** NOTE TO SPECIFIER ** Delete models not required. 2. Model 1190A: Fail-safe. 3. Model 2090A: Fail-secure. ** NOTE TO SPECIFIER ** Delete voltage not required. 4. 1190A 0.5 Amp @ 24VDC 5. Voltage: 24VDC. 2090A 3.0 Amp Inrush @ 24VDC 0.5 A Seated

ELECTRICAL LOCKING SYSTEMS 08745 - 19 6. Voltage: 24VAC. ** NOTE TO SPECIFIER ** Delete the following paragraphs for finishes not required. 7. Finish: BHMA 605: Bright brass, clear coated. 8. Finish: BHMA 606: Satin brass, clear coated. 9. Finish: BHMA 611: Bright bronze, clear coated. 10. Finish: BHMA 612: Satin bronze, clear coated. 11. Finish: BHMA 613: Dark-oxidized satin bronze, oil rubbed. 12. Finish: BHMA 625: Bright chromium plated. 13. Finish: BHMA 626: Satin chromium plated. 14. Finish: BHMA 628: Satin aluminum, clear anodized. 15. Finish: BHMA 630: Satin stainless steel. 16. Finish: BHMA 335: Dark-oxidized satin bronze anodized. 17. Finish: BHMA 335: Black Duronodic

D. Universal Surface Mounted Type: SDC 180/ 280 Series electric bolt lock. Continuous duty solenoid; Fully enclosed electronics. ** NOTE TO SPECIFIER ** Delete models not required. 1. Model 180: Fail-safe. 2. Model 180A: Fail-safe; Auto Relock Switch. 3. Model 280: Fail-secure. ** NOTE TO SPECIFIER ** Delete voltage not required. 4. Voltage: 12VDC. 5. Voltage: 24VDC. 6. Voltage: 24VAC. ** NOTE TO SPECIFIER ** Delete the following paragraphs for finishes not required. 7. Finish: BHMA 628: Satin aluminum, clear anodized. 8. Finish: BHMA 710: Dark-oxidized satin bronze anodized. 9. Finish: BHMA 711: Flat black anodized.

E. Gate Mounted Type: SDC 160/ 260 Series electric bolt gate lock. Continuous duty solenoid; Fully enclosed electronics. Designed for outdoor mounting; swinging or sliding gates. Housing and tongue cadmium plated. ** NOTE TO SPECIFIER ** Delete models not required. 1. Model 160A: Fail-safe; Remote Operation. 2. Model 163A: Fail-safe; Remote and Electrical Key Cylinder Operation. 3. Model 260A: Fail- secure; Remote Operation. 4. Model 263A: Fail- secure; Remote and Mechanical Key Cylinder Operation. ** NOTE TO SPECIFIER ** Delete voltage not required. 5. Dual Voltage: 12VDC. Failsafe. 12VDC. Failsecure. 6. Dual Voltage: 24VDC. Failsafe. 24VDC. Failsecure. 24VAC. Failsecure. ** NOTE TO SPECIFIER ** The following paragraphs are optional. Delete if not required. 7. Provide Gate Position (DPS-GL) monitor.

2.7 ELECTRIC STRIKES ** NOTE TO SPECIFIER ** The following describes various models of electric strikes. Delete all types not required. If more than one type is required, give each a type designation and indicate type on Door Schedule.

A. SDC 20 Series electric strikes for use with cylindrical locks, or mortise locks without dead bolts, having 1/2 inch bolt throw. Internally mounted solenoid for use with 12 or 24VDC, built for long life. Durable die cast body for long life and corrosion resistance; non- handed, reversible; plug-in connector included. Fail secure is standard; field reversible to fail safe. 1. ANSI/BHMA A156.5 Grade 1 and UL 1034 burglary resistant. 2. Voltage: 12VDC @ 0.33 Amp, 24VDC @ 0.16 Amp.

ELECTRICAL LOCKING SYSTEMS 08745 - 20 ** NOTE TO SPECIFIER ** Delete models not required. 3. Model 20-4S: 4-7/8 inch faceplate; square corners; for wood or hollow metal frames. 4. Model 20-6S: 6-7/8 inch faceplate; square corners; for wood or hollow metal frames. 5. Model 20-4R: 4-7/8 inch faceplate; radius corners; for aluminum frames. 6. Model 20-6R: 6-7/8 inch faceplate; radius corners; for aluminum frames. ** NOTE TO SPECIFIER ** The following paragraphs are optional. Delete if not required. 7. Provide rectifier (BR64XL) for AC operation. ** NOTE TO SPECIFIER ** Delete the following paragraphs for finishes not required. 8. Finish: BHMA 605: Bright brass, clear coated. 9. Finish: BHMA 606: Satin brass, clear coated. 10. Finish: BHMA 611: Bright bronze, clear coated. 11. Finish: BHMA 612: Satin bronze, clear coated. 12. Finish: BHMA 613: Dark-oxidized satin bronze, oil rubbed. 13. Finish: BHMA 625: Bright chromium plated. 14. Finish: BHMA 626: Satin chromium plated. 15. Finish: BHMA 628: Satin aluminum, clear anodized. 16. Finish: BHMA 629: Bright stainless steel. 17. Finish: BHMA 630: Satin stainless steel. 18. Finish: BHMA 710: Dark-oxidized satin bronze anodized. 19. Finish: BHMA 711: Flat black anodized.

B. SDC 30 Series electric strikes for use with cylindrical locks, mortise locks without dead bolts, or mortise exit devices, having 1/2 inch or 5/8 inch bolt throw, and rim-type exit devices having 3/4 inch pullman type latchbolt, or the top pullman latch of a surface vertical-rod device. All stainless steel, tamper resistant, heavy-duty construction. Available for use with 12 or 24VDC; fail-secure standard, fail-safe optional. Horizontal keeper adjustment for door alignment. Non-handed, reversible. 1. ANSI/BHMA A156.5 Grade 1 and UL 1034 burglary resistant. 2. UL listed for use on fire doors up to 3 hours (fail-secure only). ** NOTE TO SPECIFIER ** Delete voltage not required. 3. Voltage: 12VDC @ 0.29 Amp. 4. Voltage: 24VDC @ 0.15 Amp. ** NOTE TO SPECIFIER ** Delete models not required. 5. Model 30-2: 9 inch faceplate; square corners; for use with cylindrical locks, mortise locks without dead bolts, or mortise exit devices, having 1/2 inch or 5/8 inch bolt throw; for wood or hollow metal frames. 6. Model 30-4: 9 inch faceplate; square corners; for use with rim-type exit devices having 3/4 inch pullman type latchbolt, or the top pullman latch of a surface vertical-rod device; for wood or hollow metal frames. ** NOTE TO SPECIFIER ** The following paragraphs are optional. Delete if not required. 7. Provide fail-safe (FS) operation (Not UL Listed). 8. Provide plug connector (PC). 9. Provide internal switch (LBM) to monitor position of lock latchbolt. 10. Provide internal switch (LCM) to monitor locked/ unlocked status of strike locking cam. 11. Provide rectifier (BR64XL) for AC operation. ** NOTE TO SPECIFIER ** Delete the following paragraphs for finishes not required. 12. Finish: BHMA 606: Satin brass, clear coated. 13. Finish: BHMA 612: Satin bronze, clear coated. 14. Finish: BHMA 613: Dark-oxidized satin bronze, oil rubbed. 15. Finish: BHMA 625: Bright chromium plated. 16. Finish: BHMA 626: Satin chromium plated. 17. Finish: BHMA 630: Satin stainless steel.

ELECTRICAL LOCKING SYSTEMS 08745 - 21 C. SDC 40 Series electric strikes for use with cylindrical locks, mortise locks without dead bolts, or mortise exit devices, having 3/4 inch bolt throw. Stainless steel internal parts, tamper resistant, heavy-duty construction. Available for use with 12 or 24VDC; fail-secure standard, fail-safe optional. Horizontal keeper adjustment for door alignment. Non- handed, reversible; plug-in connector included. 1. ANSI/BHMA A156.5 Grade 1 and UL 1034 burglary resistant. ** NOTE TO SPECIFIER ** Delete voltage not required. 2. Voltage: 12VDC @ 0.29 Amp. 3. Voltage: 24VDC @ 0.15 Amp. ** NOTE TO SPECIFIER ** Delete models not required. 4. Model 40-4S: 4-7/8 inch faceplate; square corners; for hollow metal frames. 5. Model 40-6S: 6-7/8 inch faceplate; square corners; for hollow metal frames. 6. Model 40-4R: 4-7/8 inch faceplate; radius corners; for aluminum frames. 7. Model 40-6R: 6-7/8 inch faceplate; radius corners; for aluminum frames. 8. Model 40-W4S: 4-7/8 inch faceplate; square corners and offset solenoid; for wood frames. 9. Model 40-W6S: 6-7/8 inch faceplate; square corners and offset solenoid; for wood frames. ** NOTE TO SPECIFIER ** The following paragraphs are optional. Delete if not required. 10. Provide fail-safe (FS) operation (Not UL Listed). 11. Provide internal switch (LCM) to monitor locked/ unlocked status of strike locking cam. 12. Provide rectifier (BR64XL) for AC operation. ** NOTE TO SPECIFIER ** Delete the following paragraphs for finishes not required. 13. Finish: BHMA 628: Satin aluminum, clear anodized. 14. Finish: BHMA 630: Satin stainless steel. 15. Finish: BHMA 710: Dark-oxidized satin bronze anodized. 16. Finish: BHMA 711: Flat black anodized.

D. SDC 50 Series electric strikes for use with cylindrical locks or mortise locks. Stainless steel construction, tamper resistant, inboard solenoid, heavy-duty construction. Release with 20 lb side load; available for use with 12 or 24VDC; fail-secure standard, fail-safe optional. Horizontal keeper adjustment for door alignment. Non-handed, reversible; plug- in connector included. 1. ANSI/BHMA A156.5 Grade 1 and UL 1034 burglary resistant. 2. UL listed for use on fire doors up to 3 hours (fail-secure only). 3. Fits ANSI 115.1 frame prep with face modification; for use with hollow metal or aluminum frames. ** NOTE TO SPECIFIER ** Delete voltage not required. 4. Voltage: 12VDC @ 0.29 Amp. 5. Voltage: 24VDC @ 0.15 Amp. ** NOTE TO SPECIFIER ** Delete models not required. 6. Model 51-A Cylindrical locks, narrow stile locks with deadlatch. 7. Model 52-B Mortise locks and mortise panic with or without deadlatch. 8. Model 52-C Mortise locks and mortise panic with or without deadlatch (Schlage, Sargent, Yale). 9. Model 53-D Mortise locks with deadlatch and latchbolt. When the deadbolt is projected, the strike will not release. Keeper releases latchbolt when deadbolt is retracted. 10. Model 53-E Mortise locks with deadlatch and latchbolt. When the deadbolt is projected, the strike will not release. Keeper releases latchbolt when deadbolt is retracted (Schlage, Sargent, Yale). 11. Model 53-F Mortise locks with deadbolt, deadlatch and latchbolt. When the deadbolt is projected, the strike will not release. Keeper releases latchbolt when deadbolt is retracted (Schlage, Sargent, Yale).

ELECTRICAL LOCKING SYSTEMS 08745 - 22 12. Model 54-D Mortise locks with latchbolt and extended deadbolt. Deadbolt and latchbolt are released. 13. Model 54-E Mortise locks with latchbolt and extended deadbolt. Deadbolt and latchbolt are released (Schlage, Sargent, Yale). 14. Model 54-E Cylindrical Corbin/Russwin security bolt lever locksets. 15. Model 54-F Mortise locks with deadlatch, latchbolt and extended deadbolt. Deadbolt and latchbolt are released (Schlage, Sargent, Yale). ** NOTE TO SPECIFIER ** The following paragraphs are optional. Delete if not required. 16. Provide fail-safe (FS) operation (Not UL Listed). 17. Provide internal switch (LBM) to monitor position of lock latchbolt. 18. Provide internal switch (LCM) to monitor locked/ unlocked status of strike locking cam. 19. Provide internal switches (LCMLBM) to monitor locked/ unlocked status of strike locking cam and to monitor position of lock latchbolt. 20. Provide internal switches (LCMDBM) to monitor locked/ unlocked status of strike locking cam and to monitor position of lock deadbolt. 21. Provide rectifier (BR64XL) for AC operation. ** NOTE TO SPECIFIER ** Delete the following paragraphs for finishes not required. 22. Finish: BHMA 606: Satin brass, clear coated. 23. Finish: BHMA 612: Satin bronze, clear coated. 24. Finish: BHMA 613: Dark-oxidized satin bronze, oil rubbed. 25. Finish: BHMA 625: Bright chromium plated. 26. Finish: BHMA 626: Satin chromium plated. 27. Finish: BHMA 630: Satin stainless steel.

E. SDC 70 Series electric strikes for use with cylindrical locks, mortise locks without dead bolts, or mortise exit devices, having 3/4 inch bolt throw. All stainless steel construction, tamper resistant, heavy-duty construction. Available for use with 12 or 24VDC; fail-secure standard, fail-safe optional. Horizontal keeper adjustment for door alignment. Non- handed, reversible. 1. ANSI/BHMA A156.5 Grade 1 and UL 1034 burglary resistant. 2. UL listed for use on fire doors up to 3 hours (fail-secure only). 3. Fits ANSI 115.1 frame prep with face modification; for use with hollow metal or wood frames. ** NOTE TO SPECIFIER ** Delete voltage not required. 4. Voltage: 12VDC @ 0.29 Amp. 5. Voltage: 24VDC @ 0.15 Amp. ** NOTE TO SPECIFIER ** Delete models not required. 6. Model 70-12: 4-7/8 inch faceplate; square corners; for hollow metal frames. 7. Model 70-32: 4-7/8 inch faceplate; square corners and offset solenoid; for wood frames or pair of doors. ** NOTE TO SPECIFIER ** The following paragraphs are optional. Delete if not required. 8. Provide fail-safe (FS) operation (Not UL Listed). 9. Provide plug connector (PC). 10. Provide internal switch (LBM) to monitor position of lock latchbolt. 11. Provide internal switch (LCM) to monitor locked/ unlocked status of strike locking cam. 12. Provide rectifier (BR64XL) for AC operation. ** NOTE TO SPECIFIER ** Delete the following paragraphs for finishes not required. 13. Finish: BHMA 606: Satin brass, clear coated. 14. Finish: BHMA 612: Satin bronze, clear coated. 15. Finish: BHMA 613: Dark-oxidized satin bronze, oil rubbed. 16. Finish: BHMA 625: Bright chromium plated. 17. Finish: BHMA 626: Satin chromium plated. 18. Finish: BHMA 629: Bright stainless steel. 19. Finish: BHMA 630: Satin stainless steel.

ELECTRICAL LOCKING SYSTEMS 08745 - 23 2.8 POWER SUPPLIES, CONTROLLERS AND BATTERY STANDBY ** NOTE TO SPECIFIER ** The following describes various models of power supplies. Delete all types not required. If more than one type is required, give each a type designation and indicate type on Door Schedule.

A. Modular Design Power Supplies: SDC 600 Series; filtered and regulated output; field selectable 12/24VDC; Fire Panel release input; LED indicators for input, output, and battery status; thermal and short circuit protection with auto reset; battery charging circuitry built-in; low battery disconnect. ** NOTE TO SPECIFIER ** Delete models not required. 1. Model 602RF: 1 Amp Class 2 Output, 11-1/4 inch (H) x 11-1/4 inch (W) x 3-1/2 inch (D) 18 gauge enclosure. 2. Model 602RFCUL: 1 Amp Class 2 Output, 11-1/4 inch (H) x 11-1/4 inch (W) x 3- 1/2 inch (D) 18 gauge enclosure, cUL listed for Canada. 3. Model 631RF: 1.5 Amp Class 2 Output, 11-1/4 inch (H) x 11-1/4 inch (W) x 3-1/2 inch (D) 18 gauge enclosure. 4. Model 631RFA: 1.5 Amp Class 2 Output, 16 inch (H) x 14 inch (W) x 6-1/2 inch (D) 16 gauge enclosure. 5. Model 631RFCUL: 1.5 Amp Class 2 Output, 11-1/4 inch (H) x 11-1/4 inch (W) x 3-1/2 inch (D) 18 gauge enclosure, cUL listed for Canada. 6. Model 632RF: 2 Amp Class 2 Output, 11-1/4 inch (H) x 11-1/4 inch (W) x 3-1/2 inch (D) 18 gauge enclosure. 7. Model 632RFA: 2 Amp Class 2 Output, 16 inch (H) x 14 inch (W) x 6-1/2 inch (D) 16 gauge enclosure. 8. Model 632RFCUL: 2 Amp Class 2 Output, 11-1/4 inch (H) x 11-1/4 inch (W) x 3- 1/2 inch (D) 18 gauge enclosure, cUL listed for Canada. 9. Model 634RF: Field Selectable one 4 Amp or two 2 Amp Class 2 Outputs, 16 inch (H) x 14 inch (W) x 6-1/2 inch (D) 16 gauge enclosure. 10. Model 636RF: Field Selectable one 6 Amp or three 2 Amp Class 2 Outputs, 16 inch (H) x 14 inch (W) x 6-1/2 inch (D) 16 gauge enclosure. ** NOTE TO SPECIFIER ** The following paragraphs are optional. Delete if not required. 11. Provide 6 foot power cord (PC) at 1-1.5 Amp power supplies: 12. Provide key lock (KL) cover. 13. Provide cover-mounted manual reset switch (MR) for fire alarm release reset. 14. Provide system on/off push switch (PS-1) mounted inside power supply. 15. Provide system on/off push switch (PS-1A) mounted on cover. ** NOTE TO SPECIFIER ** Delete modules not required. 16. Provide Model 12VR Module: With power supply output set at 24VDC, adds separate, regulated filtered output of 12VDC @ 0.50 Amp for access control or other device. 17. Provide Model ACM-1 Module: Access Control Board. SPDT voltage output. SPDT status output, 8 trigger inputs (4 NO, 4 NC), LED status indicator. 18. Provide Model CR Module: Control Relay Board. Fused SPDT voltage output, SPDT trigger input. 19. Provide Model CR4 Module: Control Relay Board. 4 Fused SPDT voltage outputs, 4 SPDT trigger inputs. 20. Provide Model FB-4 Module: Fused Terminal Board. 4 individually fused outputs. 21. Provide Model LR Module: Latching Relay, SPDT fused output. 22. Provide Model TD Module: 1-120 second adjustable time delay, SPDT fused output, SPDT trigger input. 23. Provide Model UR-2A Module: Universal Controller for 2 doors. Field select TD, LR, TD/LR, Mantrap and Communicating Bathroom Interlock. (2) Fused SPDT dry outputs, 5 Amp @ 30VDC. (2) SPDT dry outputs, 1 Amp @ 30VDC. (2) Inputs per station, (4) Auxiliary inputs. 24. Provide Model UR-4A Module: Universal Controller for 4 doors. Field select TD, LR, CR, TD/LR, Mantrap and Communicating Bathroom Interlock. (4) Fused

ELECTRICAL LOCKING SYSTEMS 08745 - 24 SPDT dry outputs, 5 Amp @ 30VDC. (4) SPDT dry output, 1 Amp @ 30VDC. (2) Inputs per stations, (4) Auxiliary inputs. ** NOTE TO SPECIFIER ** The following paragraphs are optional. Delete if not required. 25. Provide Model RB12V4 backup battery (1 each for 12VDC output; 2 each at 24VDC output) rated for 4 Amp Hour backup power. 26. Provide Model RB12V7 backup battery (1 each for 12VDC output; 2 each at 24VDC output) rated for 7 Amp Hour backup power.

2.9 ACCESS CONTROLS ** NOTE TO SPECIFIER ** The following describes various models of access controls. Delete all types not required. If more than one type is required, give each a type designation and indicate type on Door Schedule.

A. Integrated Stand Alone Keypad for Interior Use: SDC 917 EntryCheck Series. Self- contained electronics; Non-volatile EEPROM Memory; 120 PIN Codes, 1 to 6 digits in length, programmable for individual or simultaneous control of 1 relay output and 4 voltage outputs - momentary, timed or latching. Automatic time-out, REX input, duress alarm, forced entry alarm, 3 LEDs. .Single-gang, flush-mount. 1. Relay output: Form C SPDT, 6 Amps @ 30VDC 2. Outputs 1,2,3,4: Switch to common, 500mA @ 24VDC. 3. Voltage: 12/24V AC/DC @ 0.02 Amp typical, 0.12 Amp maximum. ** NOTE TO SPECIFIER ** Delete the following paragraphs for finishes not required. 4. Finish: BHMA 605: Bright brass, clear coated. 5. Finish: BHMA 606: Satin brass, clear coated. 6. Finish: BHMA 613: Dark-oxidized satin bronze, oil rubbed. 7. Finish: BHMA 625: Bright chromium plated. 8. Finish: BHMA 630: Satin stainless steel.

B. Integrated Stand Alone Keypad for Exterior or Interior Use: SDC 925 EntryCheck Series. Self-contained electronics; Non-volatile EEPROM Memory; 480 PIN Codes, 1-6 digits in length, programmable for individual or simultaneous control of 2 relay outputs and 2 voltage outputs - momentary, timed or latching. Automatic time-out, REX input, duress alarm, forced entry alarm, door ajar, keypad lockout, alarm shunt, 2 LEDs. Weather-resistant, surface mount. 1. Dimensions: 5-1/2 inches (H) x 4 inches (W) x 3 inches (D). 2. Relay 1: Form “C”, 5 Amps @ 24VDC. 3. Relay 2: Form “C”, 1 Amp @ 24VDC. 4. Outputs 3 and 4: Switch to common, 100mA @ 30VDC. 5. Voltage: 12/24V AC/DC @ 0.01 Amp typical, 0.15 Amp maximum. 6. Operating Temperature: -20 degrees to +130 degrees F. 7. Operating Humidity: 5% to 95% non-condensing.

C. Integrated Stand Alone Proximity Card Reader/ Keypad for Exterior or Interior Use: SDC 950 EntryCheck Series. Self-contained electronics; Non-volatile EEPROM Memory; 400 Cards and/ or PIN Codes, 1-6 digits in length to control 2 relay outputs. Door open programmable for 1 to 99 seconds. Selectable for proximity reader only; proximity reader or PIN; proximity reader and PIN operation. Automatic time-out, REX input, tamper alarm, reader/ keypad lockout, dual color LED and audible tone. Weather-resistant, surface mount. 1. Dimensions: 5-3/4 inches (H) x 3-1/4 inches (W) x 1 inch (D). 2. Relay 1: Form “C”, 2 Amps @ 30VDC. 3. Relay 2: Form “C”, 2 Amps @ 30VDC. 4. Voltage: 12VDC @ 0.02 Amp typical, 0.04 Amp maximum. 5. Operating Temperature: 32 degrees to 122 degrees F. 6. Operating Humidity: 20% to 95% non-condensing. ** NOTE TO SPECIFIER ** The following paragraph is optional. Delete if not required.

ELECTRICAL LOCKING SYSTEMS 08745 - 25 7. Provide glass-mount kit for through-glass operation of proximity reader.

D. Stand Alone Keypad with Remote Controller for Exterior or Interior Use: SDC 931 EntryCheck Series. Remote mount controller for increased security. Non-volatile EEPROM Memory; 6 PIN Codes, 3-8 digits in length to control 2 relay outputs. Door open programmable for 1 to 120 seconds, REX input, tamper alarm, 2 user groups, anti- tailgate, keypad lockout. Relays selectable 1 door plus alarm, CCTV, or doorbell activation using 1 or 2 keypads. 1. Controller Dimensions: 7-1/2 inches (H) x 5-1/2 inches (W) x 2-1/2 inches (D). 2. Relay 1: SPDT dry contacts. 3. Relay 2: SPDT dry contacts. 4. Voltage: 12/24V AC/DC @ 0.02 Amp typical, 0.25 Amp maximum. 5. Controller Operating Temperature: -40 degrees to 120 degrees F. 6. Controller Operating Humidity: Maximum 98% non-condensing. 7. Keypad Operating Temperature: -40 degrees to 160 degrees F. ** NOTE TO SPECIFIER ** Delete all but one of the following options. 8. Keypad Style KP-2U: Economy 5 button, stainless steel, 6-5/8 inches (H) x 2-1/4 inches (W) x 1/2 inch (D), 15 foot cable. 9. Keypad Style KP-3U: 12 button, narrow frame mount, black with stainless steel overlay, red and green LEDs, 7-1/8 inches (H) x 1-3/4 inches (W) x 5/8 inch (D), 15 foot cable. 10. Keypad Style KP-3Y: 12 button, narrow frame mount, black, illuminated, red and green LEDs, 7-1/8 inches (H) x 1-3/4 inches (W) x 5/8 inch (D), 15 foot cable. 11. Keypad Style KP-4U: 12 button, single gang mount, stainless steel, red and green LEDs, 5-1/8 inches (H) x 3-3/8 inches (W) x 7/16 inch (D), 15 foot cable. ** NOTE TO SPECIFIER ** The following paragraphs are optional. Delete if not required. If required, delete all but one option. 12. Provide additional KP-2U keypad with 15 foot cable. 13. Provide additional KP-3U keypad with 15 foot cable. 14. Provide additional KP-3Y keypad with 15 foot cable. 15. Provide additional KP-4U keypad with 15 foot cable.

E. Stand Alone Keypad with Remote Controller for Exterior or Interior Use: SDC 935 EntryCheck Series. Remote mount controller for increased security. Non-volatile EEPROM Memory; 500 PIN Codes, 3-8 digits in length; 24 hour clock, 16 user groups, 16 time zones, holiday schedule. Controls 1 main relay output and 2 programmable auxiliary relay outputs. Door open programmable for 1 to 99 seconds. REX input, tamper alarm, anti-tailgate, keypad lockout, duress codes, door ajar/ forced door alarm. 750 event audit trail, parallel printer port for audit printing. 1. Controller Dimensions: 7-3/4 inches (H) x 7-1/8 inches (W) x 1-1/8 inches (D). 2. Main Relay: Form “C”, 6 Amps @ 30VDC. 3. Relays 2 and 3: Form “C”, 6 Amps @ 30VDC. 4. Voltage: 12/24V AC/DC @ 0.15 Amp. 5. Controller Operating Temperature: -40 degrees to 120 degrees F. 6. Controller Operating Humidity: Maximum 98% non-condensing. 7. Keypad Operating Temperature: -40 degrees to 160 degrees F. ** NOTE TO SPECIFIER ** Delete all but one of the following options. 8. Keypad Style KP-30U: 12 button, narrow frame mount, black with stainless steel overlay, red and green LEDs, 7-1/8 inches (H) x 1-3/4 inches (W) x 5/8 inch (D), 15 foot cable. 9. Keypad Style KP-30Y: 12 button, narrow frame mount, black, illuminated, red and green LEDs, 7-1/8 inches (H) x 1-3/4 inches (W) x 5/8 inch (D), 15 foot cable. 10. Keypad Style KP-40U: 12 button, single gang mount, stainless steel, red and green LEDs, 5-1/8 inches (H) x 3-3/8 inches (W) x 7/16 inch (D), 15 foot cable.

ELECTRICAL LOCKING SYSTEMS 08745 - 26 ** NOTE TO SPECIFIER ** The following paragraphs are optional. Delete if not required. If required, delete all but one option. 11. Provide additional KP-30U keypad with 15 foot cable for controlled egress. 12. Provide additional KP-30Y keypad with 15 foot cable for controlled egress. 13. Provide additional KP-40U keypad with 15 foot cable for controlled egress.

2.10 REQUEST-TO-EXIT PUSH BARS ** NOTE TO SPECIFIER ** The following describes various models of request-to-exit push bars. Delete all types not required. If more than one type is required, give each a type designation and indicate type on Door Schedule.

A. Pressure Sensitive Non-Latching Push Bar: SDC Sure Exit PSB560 Series. Activation with non-perceptible movement, field adjustable sensor circuits, armored power transfer loop and 10 foot jacketed cable. Triple fail safe. Operable at 12 or 24 Volt DC without field adjustment. UL Listed under categories (ALVY) Access Control System Unit, (CVXJ) Burglary Resistant Electric Locking. 1. Lock Switch: SPDT, 3 Amp @ 30VDC. 2. Alarm Shunt/ Status Switch: SPDT, 3 Amp @ 30VDC. 3. Voltage: 12/24V AC/DC @ 0.02 Amp typical, 0.12 Amp maximum. ** NOTE TO SPECIFIER ** The following paragraphs are optional. Delete if not required.. 4. Provide Model 500GL-KIT glass door mounting kit. 5. Provide Model 500-SK Shim Kit to raise bar 1/4 inch from face of door. ** NOTE TO SPECIFIER ** Delete the following paragraphs for finishes not required. 6. Finish: BHMA 605: Bright brass, clear coated. 7. Finish: BHMA 628: Satin aluminum, clear anodized. 8. Finish: BHMA 629: Bright stainless steel. 9. Finish: BHMA 630: Satin stainless steel. 10. Finish: BHMA 710: Dark-oxidized satin bronze anodized. 11. Finish: BHMA 711: Flat black anodized.

B. Mechanical Switch Non-Latching Push Bar: SDC Sure Exit MSB550 Series. Activation with 1/8 inch movement of bar. UL Listed under categories (ALVY) Access Control System Unit, (CVXJ) Burglary Resistant Electric Locking. 1. Lock Switch: SPDT, 5 Amp @ 30VDC. ** NOTE TO SPECIFIER ** Retain at least one of the following options. Delete types/ finishes not required. 2. Provide Model PT-2B black/ brown armored loop. 3. Provide Model PT-2U stainless steel armored loop. 4. Provide Model PT-3V stainless steel armored loop with aluminum surface wire junction. ** NOTE TO SPECIFIER ** The following paragraphs are optional. Delete if not required.. 5. Provide second switch for dual-failsafe redundancy, alarm shunt, or monitor output. 6. Provide Model 500GL-KIT glass door mounting kit. 7. Provide Model 500-SK Shim Kit to raise bar 1/4 inch from face of door. ** NOTE TO SPECIFIER ** Delete the following paragraphs for finishes not required. 8. Finish: BHMA 605: Bright brass, clear coated. 9. Finish: BHMA 628: Satin aluminum, clear anodized. 10. Finish: BHMA 629: Bright stainless steel. 11. Finish: BHMA 630: Satin stainless steel. 12. Finish: BHMA 710: Dark-oxidized satin bronze anodized. 13. Finish: BHMA 711: Flat black anodized.

ELECTRICAL LOCKING SYSTEMS 08745 - 27 2.11 ELECTRICAL LOCKING SYSTEM ACCESSORIES ** NOTE TO SPECIFIER ** The following describes various models of electrical locking system accessories. Delete all types not required. If more than one type is required, give each a type designation and indicate type on Door Schedule.

A. Break Glass Emergency Door Release: SDC 491 for immediate unlocking of all doors equipped with failsafe electric locks on the same circuit. SDC491 Emergency Door Release includes a 12/24 volt siren (Blue). 491BB Surface Mount Back Box available.

B. 1. Provide SDC 491 Emergency Door Release

C. Key Operated Key Switches: SDC 700 series rated 6 Amp @ 30VDC on single gang stainless steel 20 Ga. wall plate. 800 series on ¼” thick aluminum or stainless. Accepts standard US type mortise cylinder,(not included).

Provide 701U AA SPDT key switch 808ALNV 1 MO SPDT & 1 AA SPDT 701NU AA SPDT key switch 808U 1 MO SPDT & 1 AA SPDT 701TU AA SPDT key switch 808NU 1 MO SPDT & 1 AA SPDT 801ALV AA SPDT key switch 808TU 1 MO SPDT & 1 AA SPDT 801ALNV AA SPDT key switch 709U 2 AA SPDT key switch 801U AA SPDT key switch 709NU 2 AA SPDT key switch 801UN AA SPDT key switch 709TU 2 AA SPDT key switch 801TU AA SPDT key switch 809ALV 2 AA SPDT key switch 702U MO SPDT key switch 809ALNV 2 AA SPDT key switch 702NU MO SPDT key switch 809U 2 AA SPDT key switch 702TU MO SPDT key switch 809NU 2 AA SPDT key switch 8021ALV MO SPDT key switch 809TU 2 AA SPDT key switch 802ALNV MO SPDT key switch 710U 1-60 Timer & 1 AA SPDT MO 802U MO SPDT key switch 710NU 1-60 Timer & 1 AA SPDT MO 802UN MO SPDT key switch 710TU 1-60 Timer & 1 AA SPDT MO 802TU MO SPDT key switch 810ALV 1-60 Timer & 1 AA SPDT MO 704U 1-60 TIMER SPDT X MO 810ALNV 1-60 Timer & 1 AA SPDT MO 704NU 1-60 TIMER SPDT X MO 810U 1-60 Timer & 1 AA SPDT MO 704TU 1-60 TIMER SPDT X MO 810NU 1-60 Timer & 1 AA SPDT MO 804ALV 1-60 TIMER SPDT X MO 810TU 1-60 Timer & 1 AA SPDT MO 804ALNV 1-60 TIMER SPDT X MO 711U 2 MO DPDT key switch 804U 1-60 TIMER SPDT 711NU 2 MO DPDT key switch 804NU 1-60 TIMER SPDT 711TU 2 MO DPDT key switch 804TU 1-60 TIMER SPDT 811ALV 2 MO DPDT key switch 705U AA DPDT key switch 811ALNV 2 MO DPDT key switch 705NU AA DPDT key switch 811U 2 MO DPDT key switch 705TU AA DPDT key switch 811NU 2 MO DPDT key switch 805ALV AA DPDT key switch 811TU 2 MO DPDT key switch 805ALNV AA DPDT key switch 712U 1 MO DPDT & 1 AA DPDT 805U AA DPDT key switch 712NU 1 MO DPDT & 1 AA DPDT 805NU AA DPDT key switch 712TU 1 MO DPDT & 1 AA DPDT 805TU AA DPDT key switch 812 ALV 1 MO DPDT & 1 AA DPDT 706U MO DPDT key switch 812ALNV 1 MO DPDT & 1 AA DPDT 706NU MO DPDT key switch 812U 1 MO DPDT & 1 AA DPDT 706TU MO DPDT key switch 812NU 1 MO DPDT & 1 AA DPDT 806ALV MO DPDT key switch 812TU 1 MO DPDT & 1 AA DPDT

ELECTRICAL LOCKING SYSTEMS 08745 - 28 806ALNV MO DPDT key switch 713U 2 AA DPDT key switch 806U MO DPDT key switch 713NU 2 AA DPDT key switch 806NU MO DPDT key switch 713TU 2 AA DPDT key switch 806TU MO DPDT key switch 813ALV 2 AA DPDT key switch 707U 2 MO DPDT key switch 813ALNV 2 AA DPDT key switch 707NU 2 MO DPDT key switch 813U 2 AA DPDT key switch 707TU 2 MO DPDT key switch 813NU 2 AA DPDT key switch 807ALV 2 MO DPDT key switch 813TU 2 AA DPDT key switch 808ALNV 1 MO SPDT & 1 AA SPDT 802ALNV MO SPDT key switch 10Amp 808U 1 MO SPDT & 1 AA SPDT 802U MO SPDT key switch 10Amp 808NU 1 MO SPDT & 1 AA SPDT 802UN MO SPDT key switch 10Amp 808TU 1 MO SPDT & 1 AA SPDT 802TU MO SPDT key switch 10Amp 709U 2 AA SPDT key switch 801U AA SPDT key switch 10Amp 709NU 2 AA SPDT key switch 801UN AA SPDT key switch 10Amp 701U AA SPDT key switch 10Amp 801TU AA SPDT key switch 10Amp 701U AA SPDT key switch 10Amp 702U MO SPDT key switch 10Amp 701NU AA SPDT key switch 10Amp 702NU MO SPDT key switch 10Amp 701TU AA SPDT key switch 10Amp 702TU MO SPDT key switch 10Amp 801ALV AA SPDT key switch 10Amp 8021ALV MO SPDT key switch10Amp 801ALNV AA SPDT key switch 10Amp

Finishes:

U 630 Satin stainless steel standard for all 700 and 800 series key switches except 800Al.l. V 628 Anodized Aluminum Standard finish for 800AL only.

Special finishes C 605 Bright Brass D 605 Satin Brass F 611 Bright Bronze P 625 Bright Chrome G 612 Satin Bronze X 313 Dark Bronze Anodized H 613 Oil Rubbed Bronze (313 For 800AL only) 335 Black Duronodic

OPTIONS 10TD Mini Timer adj. 1-60 /sec. 12/24VDC. SPDT CYL-KD 1 ¼” Key Cylinder with 2 keys (keyed different) L1 One LED. Specify RED or Green L2 Two LED’s Red and Green LT One tricolor LED. Red, Green, Amber ATS Anti-tamper sensor SPDT RMB Buzzer (12v-24VDC, 20mA SN 85db siren ( 4v-28VDC, 18 mA

ELECTRICAL LOCKING SYSTEMS 08745 - 29 D.

E. Push Button Switches: 400 Series 3/4'’ Square Button 5 Amp @ 30 VAC/DC 401U AA SPDT Push Switch 402U MO SPDT Push Switch 403U 1-60 Sec. Elec. Adj. Time Delay X MO 404U MO DPDT Push Switch 405U AA DPDT Push Switch 406U 2-MO SPDT Push Switch

2” Square Push Switches Illuminated 10 Amp @ 30 VAC/DC

422GEU Green Lens ,engraved “EXIT”, MO, SPDT push switch 422REU Red Lens, engraved “EXIT”, MO, SPDT push switch 422GPEU Green Lens engraved “PUSH TO EXIT”, NFPA,BOCA compliant push switch 422RPEU Red Lens, engraved “ PUSH TO EXIT”, NFPA,BOCA compliant push switch 422BAU Blue Lens, Handicap Access Symbol, Mo, SPDT push switch

Mushroom Push Switches 6 Amp @ 30 AC/DC x Single Gang Plate For Narrow Plate insert N after the part number 431RU I-1/2” Dia. Red AA Specify NO or NC push button 431GU 1-1/2” Dia. Green AA Specify NO or NC push button 431BU 1-1/2 “Dia. Black AA Specify NO or NC push button 432RU 1-1/2” Dia. Red MO Specify NO or NC push button 432GU 1-1/2” Dia. Green MO Specify NO or NC push button 432BU 1-1/2” Dia. Black MO Specify NO or NC push button 432RKRU 1-1/2” Dia. Red Latching w/Key Reset push button 433RU 1-1/2 Dia Red 1-60 Sec. Adj. Timer push button x Dbl gang plate 433GU 1-1/2” Dia Green 1-60 Sec. Adj. Timer push button x Dbl gang plate 433BU 1-1/2” Dia. Black 1-60 Sec Adj. Timer push button x Dbl gang plate 434RU 1-1/2” Dia.Red MO, NO x NC push button 434GU 1-1/2” Dia. Green MO, NO x NC push button 434BU 1-1/2” Dia. Black MO, NO x NC push button 435RU 1-1/2” Dia. Red AA NO x NC push button 435GU 1-1/2” Dia. Green AA NO x NC push switch 435BU 1-1/2” Dia. Black AA NO x NC push switch 441RU 2-5/8” Dia. Red AA, NO & NC push switch X Dbl gang plate 441GU 2-5/8” Dia. Green AA, NO & NC push switch x Dbl gang plate 441BU 2-5/8” Dia. Black AA, NO & NC push switch x Dbl gang plate 442RU 2-5/8” Dia. Red MO, NO & NC push switch x Dbl gang plate 442GU 2-5/8” DIA Green MO, NO & NC push switch x Dbl gang plate 442BU 2-5/8” Dia. Black MO, NO & NC push switch x Dbl gang plate 443RU 2-5/8” Dia. Red, 1-60 sec Adj. Timer x Dbl gang plate 443GU 2-5/8” Dia Green, 1-60 Sec. Adj, Timer x Dbl gang plate 443BU 2-58” Dia. Black , 1-60 Sec. Adj. Timer x Dbl. Gang plate 444RU 2-5/8” Dia. Red, MO, 2NO, 2NC x Dbl. Gang plate (3” depth) 444GU 2-5/8” Dia. Green , MO, 2NO, 2NC x Dbl. Gang plate (3” depth) 444BU 2-5/8” Dia. Black, MO, 2NO, 2NC x Dbl gang plate (3” depth) 446GEU 2-5/8” Dia. MO DPDT “EXIT” push button

ELECTRICAL LOCKING SYSTEMS 08745 - 30 VANDAL RESISTANT STEEL PUSH SWITCH WITH ¼” THICK ALUMINUM PLATE

451V AA,SPDT single gang push switch 451NV AA, SPDT Narrow push switch 452V MO, SPDT push switch 452VPTD 2-60 Sec. Adj. Pneumatic SPDT Time Delay 10 Amp Res. 452NV MO , SPDT Narrow push switch 452NVPTD 2-60 Second Adj. Pneumatic SPDT Time Delay 10 Amp Resistive

Finishes:

U 630 Satin stainless steel standard for all 700 and 800 series key switches except 800AL. V 628 Anodized Aluminum Standard finish for 800AL only.

Special Finishes: C 605 Bright Brass D 605 Satin Brass F 611 Bright Bronze P 625 Bright Chrome G 612 Satin Bronze X 313 Dark Bronze Anodized H 613 Oil Rubbed Bronze (313 For 800AL only) Y 335 Black Duronodic

Options

F. Mini Consoles for one or two doors DTMO-1 (1) Momentary switch and (1) LED DTMO-2 (2)Momentary switches and (2) LED DTMOMA-2 (1) Momentary, (1) Maintained and (2) LEDs DTMA-2 (2) Maintained switches and (2) LEDs

G. Modular Control Consoles TCC Slope Front Desk Top Design (12) Stations maximum when using (2) control panels Base unit is: Less Panels Color: Black side and beige top (10-1/4”W x 4-3/4”H x 9-%/8”D) RCC Rack Mount Console (24) Stations maximum when using (3) control panels Maximum is 20 stations with” E” panel Base unit is less panels. Color: Beige (19”W x 5-1/4” H x 6” D)

H. Switch and Indicator Panels Select panels to be installed in TCC or RCC chassis

Rocker Switch Rating: 3 Amp @ 30VDC Power required per LED:.02 Amp @ 24VDC AL4 (4) Momentary switches with LEDs BL4 (4) Maintained switches with LED s CL4 (4) Momentary/Off/Maintained switches with LEDs DL4 (4) Momentary/Off/Momentary switches with LEDs

AL8 (8) Momentary switches with LEDs BL8 (8) Maintained switches with LEDs CL8 (8) Momentary/Off/Maintained switches with LEDs

ELECTRICAL LOCKING SYSTEMS 08745 - 31 DL8 (8) Momentary/Off/Momentary switches with LEDs

AL4E (4) Momentary switches with LEDs, Alarm, Reset Push Buttons and Key Lock BL4E (4) Maintained switches with LEDs, Alarm, Reset Push Buttons and Key Lock CL4E (4) Momentary/Off/ maintained switches with LEDs, Alarm, Reset Push Buttons and Key Lock DL4E (4) Momentary/Off/Momentary switches with LEDs Alarm, Reset Push Button and Key Lock EA Panel with Alarm, Reset Push Button and Key Lock F Blank Panel

I. Cabinets CAB7 Black cabinet for 1 RCC (7” H x 20-1/2” W x 14-1/2” D) CAB12 Black cabinet for (2) RCC (12-1/2 H x 20-1/2” W x 14-1/2 D)

J. Latch and Deadbolt Monitor Strikes SPDT Rated 5 Amp.@ 30VAC/DC Strike furnished by others Non Handed MS-12 For cylindrical latch or deadbolt Monitor SPDT 2-3/4” strike MS-12D For cylindrical latch or deadbolt Monitor DPDT 2-3/4” strike MS-14 For cylindrical latch or deadbolt Monitor SPDT 4-7/8” strike MS-14D For cylindrical latch or deadbolt Monitor DPDT 4-7/8” strike MS-16 For mortise latchbolt Monitor SPDT 4-7/8” field reversible MS-16D For mortise latchbolt Monitor DPDT 4-7/8” field reversible MS-18 For mortise lock deadbolt Monitor SPDT 4-7/8”,field reversible MS-18D For mortise lock deadbolt Monitor DPDT 4-7/8” field reversible MS-20 For dual mortise latch and deadbolt Monitor SPDT 4-7/8”, non handed MS-20D For dual mortise latch and deadbolt Monitor DPDT 4-7/8” non handed

K. Passive Infrared Egress Control MD-31D-OW Motion Detector with Time Delay – Off white MD-31D-B Mootion Detector with Time Delay – Black

L. Timer, Time Delay Relay 10TD Time Delay Relay Module with adjustable 1-60 second relock delay Input: 12/24V AC/DC. Output SPDT dry contact 2 Amps @ 30VDC (resistive) Size , 2-1/4” x 1-1/2” x3/4”.

14-2 & day Programmable Timer with Memory Battery back-up capability 1 SPDT Dry contact !6 Amp. @ 30VAC/DC Specify 12V or @4V AC/DC

M. Sirens And Buzzers: 630 Stainless Steel Standard 400-RMB Buzzer on Sgle gang plate . (specify 12VDC or 24VDC, 20mA max.) 400N-RMB Buzzer on narrow plate (specify 12VDC or 24VDC, 20mA max.) 400-SN Siren on Sgl. Gang plate (3-28VDC, 18mA max. 400N-SN Siren on narrow plate (3-28VDC,18mA max.

N. Power Transfer Devices PT-2 Armored Flex Conduit (less wires 18” long PT-3 Armored Flex Conduit (less wires) with wire junction box PT-5 Concealed Power Transfer PTH-2 Power Transfer Hinge (2 wires) 20 AWG 5 Amp @ 24V AC/DC PTH-4 Power Transfer Hinge (4 wires) 28 AWG 5 Amp @ 24V AC/DC PTH-10 Power Transfer Hinge (10 wires) 30 AWG 5 Amp @ 24V AC/DC

PART 3-EXECUTION

ELECTRICAL LOCKING SYSTEMS 08745 - 32 2.12 EXAMINATION

A. Do not begin installation until substrates have been properly prepared.

B. Proceed with installation only after unsatisfactory conditions have been corrected.

2.13 INSTALLATION

A. Install each item according to manufacturer's written instructions, utilizing proper fasteners provided by manufacturer.

B. Items for fire doors shall be installed conforming with NFPA 80, and all other applicable building codes and regulations.

C. Set units level, plumb, and true to line and location. Adjust and reinforce attachment substrates as necessary for proper installation and operation.

2.14 ADJUSTING

A. Adjust and check each operating item of door hardware and each door to ensure proper operation or function of every unit. Replace units that cannot be adjusted to operate as intended.

B. Test for proper operation with building power energized; coordinate with startup procedures of other installers.

END OF SECTION

ELECTRICAL LOCKING SYSTEMS 08745 - 33