MINUTES OF THE OHIO CORROSION COMMITTEE BELLVILLE, OHIO 9/10//2008

Chairman, Lenny Schramm, called the meeting to order @ 9:35 a.m.

The minutes were read and we reviewed. Cases were reviewed and company indexes were updated.

Next Year’s Meeting Schedule:

Wednesday December 10, 2008

OHIO CORROSION COMMITTEE CASES

NEW CASES 2009

CC-01-09

Rectifier_Location: N E Corner Beaver Creek Reservoir RectifierLocation_City: Clyde Rectifiercountry: 43410 Rectifier_County: Seneca Rectifier_GPS_N-: 41 1431.56 Rectifier_GPS_W-: 83 00 54.99 Ground_Bed_Type: Local Rated_Output-_volts: 38 Rated_Output_Amps: 5.10 Present_Output-_volts: 38 Present_Output_Amps: 7.90 Contact_Name: Don Ball Contact_Company: City of Clyde Contact_Phone_#: 419-547-9805 Contact_E-mail: [email protected] Proposed_Test_Date:: 10-1-08 Companies_Involved:: Buckeye, Columbia Gas, North Coast Comments_About_New_Case: Crosses these pipelines .15 Miles N of BC Res. 41.239.46 N 083.01939 W

CC-02-09

Rectifier_Location: SW corner Raccoon Creek Reservoir RectifierLocation_City: Clyde Rectifiercountry: 43410 Rectifier_County: Sandusky Rectifier_GPS_N-: 41 17 16.52 Rectifier_GPS_W-: 82 58 50.17 Ground_Bed_Type: Local Rated_Output-_volts: 38 Rated_Output_Amps: 5.10 Present_Output-_volts: 38 Present_Output_Amps: 7.90 Contact_Name: Don Ball Contact_Company: City Of Clyde Contact_Phone_#: 419-547-9805 Contact_E-mail: [email protected] Proposed_Test_Date:: 10-1-08 Companies_Involved:: Comments_About_New_Case: 1 CC-03-09 Rectifier_Location: 1895 Granger Rd RectifierLocation_City: Medina Rectifiercountry: Rectifier_County: Medina Rectifier_GPS_N-: Rectifier_GPS_W-: Ground_Bed_Type: Local Rated_Output-_volts: 8.5 Rated_Output_Amps: 1 Present_Output-_volts: 6.7 Present_Output_Amps: .95 Contact_Name: Mark Kocak Contact_Company: COH Contact_Phone_#: 440-653-7280 Contact_E-mail: [email protected] Proposed_Test_Date:: TBA Companies_Involved:: ? Comments_About_New_Case: Solar panel installed to boost failing rectified system- Minimal impact on other structures seen.

CC-04-09 Rectifier_Location: 6781 St Rt 18 RectifierLocation_City: Medina Rectifiercountry: Rectifier_County: Medina Rectifier_GPS_N-: N 41 10.749 Rectifier_GPS_W-: W 81 57.624 Ground_Bed_Type: Local Rated_Output-_volts: 8.5 Rated_Output_Amps: 1.2 Present_Output-_volts: 7.2 Present_Output_Amps: .95 Contact_Name: Mark Kocak Contact_Company: COH Contact_Phone_#: 440-653-7280 Contact_E-mail: [email protected] Proposed_Test_Date:: TBD Companies_Involved:: TCO Comments_About_New_Case: 3 TomCat solar panels used to replace failed existing rectified system- Previous rectifier rate 25 V 18 amps is retired- three new TomCat Solar panels with Add a Cat - total volts - 24 Amps - 3.6

CC-05-09 Rectifier_Location: 3871 Columbia Rd RectifierLocation_City: Medina Rectifiercountry: Rectifier_County: Medina Rectifier_GPS_N-: N 41 10.079 Rectifier_GPS_W-: WEST 81 55.053 Ground_Bed_Type: Local Rated_Output-_volts: 8.5 Rated_Output_Amps: 1.2 Present_Output-_volts: 7.2 Present_Output_Amps: .95 Contact_Name: Mark Kocak Contact_Company: COH Contact_Phone_#: 440-653-7280 Contact_E-mail: [email protected] Proposed_Test_Date:: TBD Companies_Involved:: TCO 2 Comments_About_New_Case: 3 TomCat solar panels used to replace failed existing rectified system- Previous rectifier rate 25 V 18 amps is retired- three new TomCat Solar panels with Add a Cat - total volts - 24 Amps - 3.6

CC-06-09 Rectifier_Location: Across From 6545 SR RT 18 RectifierLocation_City: Medina Rectifiercountry: Rectifier_County: Medina Rectifier_GPS_N-: N 41 10.026 Rectifier_GPS_W-: W 81 55.398 Ground_Bed_Type: Local Rated_Output-_volts: 8.5 Rated_Output_Amps: 1.2 Present_Output-_volts: 7.2 Present_Output_Amps: .95 Contact_Name: Mark Kocak Contact_Company: COH Contact_Phone_#: 440-653-7280 Contact_E-mail: [email protected] Proposed_Test_Date:: TBD Companies_Involved:: TCO Comments_About_New_Case: 3 TomCat solar panels used to replace failed existing rectified system- Previous rectifier rate 25 V 18 amps is retired- three new TomCat Solar panels with Add a Cat - total volts - 24 Amps - 3.6

CC-07-09 Rectifier_Location: Corner of Pearl & Miner Dr RectifierLocation_City: Brunswick Rectifiercountry: Rectifier_County: Medina Rectifier_GPS_N-: Rectifier_GPS_W-: Ground_Bed_Type: Local Rated_Output-_volts: 8.5 Rated_Output_Amps: 1.2 Present_Output-_volts: 7.2 Present_Output_Amps: .95 Contact_Name: Mark Kocak Contact_Company: COH Contact_Phone_#: 440-653-7280 Contact_E-mail: [email protected] Proposed_Test_Date:: TBD Companies_Involved:: Comments_About_New_Case: New Rectified system for Miner Dr- Minimal footprint

CC-08-09 Rectifier_Location: Engle Rd - 150' North of RR tracks RectifierLocation_City: Middleberg Height Rectifiercountry: Rectifier_County: CUY Rectifier_GPS_N-: Rectifier_GPS_W-: Ground_Bed_Type: Local Rated_Output-_volts: 8.5 Rated_Output_Amps: 1.2 Present_Output-_volts: 7.2 Present_Output_Amps: .95 Contact_Name: Mark Kocak Contact_Company: COH Contact_Phone_#: 440-653-7280 Contact_E-mail: [email protected] 3 Proposed_Test_Date:: TBD Companies_Involved:: Comments_About_New_Case: New Rectified system for Engle Rd- Minimal footprint

CC-09-09 Rectifier_Location: Cleveland Rd- 300' west of Huron River RectifierLocation_City: Huron Rectifiercountry: Rectifier_County: Erie Rectifier_GPS_N-: N 41.09714 Rectifier_GPS_W-: Ground_Bed_Type: Local Rated_Output-_volts: 17 Rated_Output_Amps: 2.4 Present_Output-_volts: 14.5 Present_Output_Amps: .1.9 Contact_Name: Mark Kocak Contact_Company: COH Contact_Phone_#: 440-653-7280 Contact_E-mail: [email protected] Proposed_Test_Date:: TBD Companies_Involved:: ??? Comments_About_New_Case: 2 New Solar panels to supplement isolated existing rectified system

NEW CASES 2008 CC -01-2008

Rectifier_Location: Lima Terminal RectifierLocation_City: Lima Rectifiercountry: 45804 Rectifier_County: Allen Rectifier_GPS_N-: 40.70481 Rectifier_GPS_W-: 84.12703 Ground_Bed_Type: Local Rated_Output-_volts: Rated_Output_Amps: Present_Output-_volts: 4 Present_Output_Amps: 5 Contact_Name: Vince Dalchuk Contact_Company: Mid Valley Pipeline Contact_Phone_#: 859-630-1823 Contact_E-mail: [email protected] Proposed_Test_Date:: June 25 Companies_Involved:: Buckeye*, Dominion, Marathon Comments_About_New_Case: Rectifier is currently off.

CC -02-2008

Rectifier_Location: S/S Buckeye Rd E/O Army Tank Plant RectifierLocation_City: Fort Shawnee Rectifiercountry: 45804 Rectifier_County: Allen Rectifier_GPS_N-: 40.70840 Rectifier_GPS_W-: 84.12681 Ground_Bed_Type: Deep Well 4 Rated_Output-_volts: 50 Rated_Output_Amps: 50 Present_Output-_volts: Present_Output_Amps: 15 Contact_Name: Jeff Brown Contact_Company: Buckeye Partners Contact_Phone_#: 419-234-6095 Contact_E-mail: [email protected] Proposed_Test_Date:: will call- Oct proposed test Companies_Involved:: Mid Valley, BP, Buckeye, Columbia Gas T&D, Marathon Comments_About_New_Case: 2 X 50' wells protecting 8 lines in area

CC -03-2008

Rectifier_Location: S/S Matzinger Rd. between RR tracks RectifierLocation_City: Toledo Rectifiercountry: 43612 Rectifier_County: Lucas Rectifier_GPS_N-: 41.707209 Rectifier_GPS_W-: 83.520348 Ground_Bed_Type: Deep Well Rated_Output-_volts: 80 Rated_Output_Amps: 50 Present_Output-_volts: Present_Output_Amps: Contact_Name: Jeff Brown Contact_Company: Buckeye Partners Contact_Phone_#: 419-234-6095 Contact_E-mail: [email protected] Proposed_Test_Date:: will call Companies_Involved:: BP, Dome, Enbridge, Sun, Columbia Gas, Mid Valley Comments_About_New_Case: This 100' well is an enhancement to an existing remote groundbed. It is tied to 4 mainlines shorted to a railroad bridge. Washington Township

CC -04-2008

Rectifier_Location: S/O Cygnet E/S Rock Ridge Rd N/O Mid Valley Tankfarm RectifierLocation_City: Cygnet Rectifiercountry: 43413 Rectifier_County: Wood Rectifier_GPS_N-: 41.22947 Rectifier_GPS_W-: 83.64020 Ground_Bed_Type: Local Rated_Output-_volts: 40 Rated_Output_Amps: 16 Present_Output-_volts: 7.0 Present_Output_Amps: 8.0 Contact_Name: Jeff Brown Contact_Company: Buckeye Partners Contact_Phone_#: 419-234-6095 Contact_E-mail: [email protected] Proposed_Test_Date:: Will call involved parties Companies_Involved:: Mid Valley, Columbia Gas, NorthCoast Gas, Suburban NG, Buckeye Comments_About_New_Case: Groundbed is replacing Solether Rd Groundbed. Groundbed will protect 6 mainlines North & East of Cygnet. Bloom Township

5 CC -05-2008 Rectifier_Location: 2196 Brandeberry RectifierLocation_City: Fostoria Rectifiercountry: 44830-9766 Rectifier_County: Wood Rectifier_GPS_N-: Rectifier_GPS_W-: Ground_Bed_Type: Local Rated_Output-_volts: 115/230 Rated_Output_Amps: 5.6/2.8 Present_Output-_volts: Present_Output_Amps: 15 Contact_Name: Ken Marshall Contact_Company: Sonoc Logistics Contact_Phone_#: (330) 807-0705 Contact_E-mail: [email protected] Proposed_Test_Date:: Call to schedule Companies_Involved:: BP, Northcoast (Definite) Comments_About_New_Case: Installed 2 new undertank C.P. systems, each with it's own rectifiers, and new anodes around manifolding. One rectifier use to operate entire system, now one rectifer operates manifold area, and two tanks have their own systems. No increase in amps or voltage compared to old set up.

CC -06-2008 Rectifier_Location: Area-B, 13th & M Streets RectifierLocation_City: WPAFB Rectifiercountry: 45433 Rectifier_County: Greene Rectifier_GPS_N-: Rectifier_GPS_W-: Ground_Bed_Type: Distributed Rated_Output-_volts: 60 Rated_Output_Amps: 50 Present_Output-_volts: 15 Present_Output_Amps: 7 Contact_Name: Al Daum Contact_Company: 88th Civil Engineering Contact_Phone_#: 937-657-2335 Contact_E-mail: [email protected] Proposed_Test_Date:: open Companies_Involved:: Vectren Comments_About_New_Case: Replacement anode bed; protected structure, nuclear containment shell

CC -07-2008 Rectifier_Location: Sinclair St S/W of NORCO Tank Facility E/O Maumee River RectifierLocation_City: Toledo Rectifiercountry: 43605 Rectifier_County: Lucas Rectifier_GPS_N-: 41.680713 Rectifier_GPS_W-: 83.477416 Ground_Bed_Type: Deep Well Rated_Output-_volts: Rated_Output_Amps: Present_Output-_volts: 13 Present_Output_Amps: 6 Contact_Name: Jeff Brown Contact_Company: Buckeye Partners

6 Contact_Phone_#: 419-234-6095 Contact_E-mail: [email protected] Proposed_Test_Date:: ready to set test date Companies_Involved:: Sun, Mid Valley, Norco, BP, Col Gas Comments_About_New_Case: This is a replacement groundbed system replacing distributed with 100ft deepwell. Same output. Groundbed protecting 4 mainlines York St to W/O Maumee River.

CC -08-2008 Rectifier_Location: S/E of Maumee River 1/2 Mi S/O I-475 Bridge RectifierLocation_City: Perrysburg Rectifiercountry: 43551 Rectifier_County: Wood Rectifier_GPS_N-: 41.54311 Rectifier_GPS_W-: 83.68553 Ground_Bed_Type: Deep Well Rated_Output-_volts: 25 Rated_Output_Amps: 5 Present_Output-_volts: Present_Output_Amps: Contact_Name: Jeff Brown Contact_Company: Buckeye Partners-NORCO Contact_Phone_#: 419-234-6095 Contact_E-mail: [email protected] Proposed_Test_Date:: will call Companies_Involved:: Comments_About_New_Case: 100ft well to protect Norco 150L 8" crossing Maumee River

CC -09-2008

Rectifier_Location: 3719 Kauffman Rd. RectifierLocation_City: Fairborn Rectifiercountry: Rectifier_County: Greene Rectifier_GPS_N-: 39 47.514' Rectifier_GPS_W-: 84 04.067' Ground_Bed_Type: Deep Well Rated_Output-_volts: 40 Rated_Output_Amps: 20 Present_Output-_volts: 7 Present_Output_Amps: 8 Contact_Name: Ryan Farmer Contact_Company: Vectren Energy Contact_Phone_#: 937-440-1912 Contact_E-mail: [email protected] Proposed_Test_Date:: July 18, 2008 Companies_Involved:: Comments_About_New_Case: Z-50 pipe line

2007 Cases

CC -01-2007

Alliance, Ohio. The location is N. Mahoning Ave. & Reed st. at s/e corner of Maple Beech Park 7 The rectifier is a Universal - ES AC input is 115 volts & 2.5 amps Dc output is 20 volts & 10 amps 9,432ft of 6" wthp on N. Mahoning from Front st to West South Range rd. The main is on the Mahoning/Stark county lines in Lexington twp. The Ground bed is, surface distributed (3) mixed metal oxide anodes w/500lbs coke breeze per anode. The anodes are perpendicular (running east) to the HP main line at 25,50 & 75ft intervals.Main runs North/South I energized this rectifier last Tuesday 04/10/2007 Contact: Terry Parrish

CC- 03-2007

Rectifier_Location: NS Tait Rd. between Tod & Highland RectifierLocation_City: Lordstown Rectifiercountry: Rectifier_County: Trumbull Rectifier_GPS_N-: 41.196000 Rectifier_GPS_W-: 80.838736 Ground_Bed_Type: Local Rated_Output-_volts: 30 Rated_Output_Amps: 22 Present_Output-_volts: 11 Present_Output_Amps: 8.5 Contact_Name: Bob Schneider Contact_Company: Dominion East Ohio Contact_Phone_#: 330-575-0351 Contact_E-mail: [email protected] Proposed_Test_Date:: Companies_Involved:: NCL Natural Resources Comments_About_New_Case: Replaced groundbed Note New Cases----- CC- 04-2007

Rectifier_Location: Buckeye Sun JN N/O Curtice Rd E/O I-280 RectifierLocation_City: Northwood Rectifiercountry: 43619 Rectifier_County: Wood Rectifier_GPS_N-: 41.61608 Rectifier_GPS_W-: 83.47359 Ground_Bed_Type: Deep Well Rated_Output-_volts: 15 Rated_Output_Amps: 5 Present_Output-_volts: 7 Present_Output_Amps: 2.5 Contact_Name: Jeff Brown Contact_Company: Buckeye Partners Contact_Phone_#: 419-234-6095 Contact_E-mail: [email protected] Proposed_Test_Date:: May 5-10 2008 Companies_Involved:: Sun*, North Coast, Buckeye*, Columbia Gas, Mid Valley Comments_About_New_Case: Replacing distributed bed with deepwell. connecting to 6 main lines.

8 CC- 05-2007 Rectifier_Location: Bauman Hill Rd 1/4 mile east of Sugar Grove Rd RectifierLocation_City: Lancaster Rectifiercountry: Rectifier_County: Fairfield Rectifier_GPS_N-: 39.69131 Rectifier_GPS_W-: 082.56277 Ground_Bed_Type: Local Rated_Output-_volts: 40 Rated_Output_Amps: 22 Present_Output-_volts: 29.9 Present_Output_Amps: 20.1 Contact_Name: Dan Robey Contact_Company: Columbia Gas Transmission Contact_Phone_#: 740-892-5224 Contact_E-mail: [email protected] Proposed_Test_Date:: Contact COH Companies_Involved:: Texas Eastern, AEP, COH Comments_About_New_Case: Energized 11/13/2007

2006 Cases

Case 01-2006 Comments_About_New_Case: New Installation Companies_Involved:: AEP*, Marathon company: Columbia Gas Trans. Contact_Company: Columbia Gas Trans. Contact_E-mail: mailto:[email protected] Contact_Name: Dan Robey Contact_Phone_#: 740.892.5224 email: mailto:[email protected] Ground_Bed_Type: Local name: Dan Robey phone_no: 740.892.5224 Present_Output-_volts: 4.77 Present_Output_Amps: 2.26 Proposed_Test_Date:: Rated_Output-_volts: 40 Rated_Output_Amps: 22 Rectifiercountry: RectifierLocation_City: Harpster Rectifier_address_additional: Across from Twp Rd 125 N/S of SR 294 E. of Harpster Rectifier_County: Wyandot Rectifier_GPS_N-: Rectifier_GPS_W-: Rectifier_Location: State Route 294

CC Case 05-2006 Comments_About_New_Case: #1 of 2 new ground beds installed for BP Pipelines North America on BP Marine Dock Pipelines between BP Toledo Refinery (Cedar Point Road) & BP Marine Dock located at Millard & Jessie Streets. Companies_Involved:: BP Pipelines, Buckeye, Mid Valley, Sun Pipeline, MAPL* company: Corrpro Companies, Inc. Contact_Company: Corrpro Companies, Inc.

9 Contact_E-mail: mailto:[email protected] Contact_Name: John Detamore Contact_Phone_#: 330-723-5082, x 1413 email: [email protected] Ground_Bed_Type: Deep Well name: John Detamore phone_no: 330-723-5082, x1413 Present_Output-_volts: 22.5 Present_Output_Amps: 7.75 Proposed_Test_Date:: To be determined Rated_Output-_volts: 40 Rated_Output_Amps: 22 Rectifiercountry: 43616 RectifierLocation_City: Oregon Rectifier_address_additional: BP Refinery Fence - Groundbed located approx 30 feet inside refinery, Rectifier_County: Lucas Rectifier_GPS_N-: 41.67422 Rectifier_GPS_W-: 83.46504 Rectifier_Location: Rectifier located on Otter Creek Road, 360 feet north of Cedar Point Road at

CC Case 06-2006 Comments_About_New_Case: #2 of 2 new ground beds installed for BP Pipelines North America on BP Marine Dock Pipelines between BP Toledo Refinery (Cedar Point Road) & BP Marine Dock located at Millard & Jessie Streets. Companies_Involved:: BP Pipelines, Buckeye, Mid Valley, Sun Pipeline, MAPL*, COH, NORCO company: Corrpro Companies, Inc. Contact_Company: Corrpro Companies, Inc. Contact_E-mail: mailto:[email protected] Contact_Name: John Detamore Contact_Phone_#: 330-723-5082, x 1413 email: [email protected] Ground_Bed_Type: Deep Well name: John Detamore phone_no: 330-723-5082, x1413 Present_Output-_volts: 15.5 Present_Output_Amps: 6.6 Proposed_Test_Date:: To be determined Rated_Output-_volts: 40 Rated_Output_Amps: 22 Rectifiercountry: 43616 RectifierLocation_City: Oregon Rectifier_address_additional: of Jessie & Lee Streets Rectifier_County: Lucas Rectifier_GPS_N-: 41.68037 Rectifier_GPS_W-: 83.47874 Rectifier_Location: Rectifier located on north side of gravel road at Fence, 160 feet east of intersection.

CC Case 09 – 2006

Comments_About_New_Case: This was an existing rectifier / groundbed that was replaced after it had began to fail. Companies_Involved:: company: Tennessee Gas Pipeline, AEP, COH* Contact_Company: Tennessee Gas Pipeline Contact_E-mail: mailto:[email protected] Contact_Name: Dan Achauer Contact_Phone_#: 740-638-2101 ext 2029 10 email: [email protected] Ground_Bed_Type: Local name: Dan Achauer phone_no: 740-638-2101 ext 2029 Present_Output-_volts: 19.2 Present_Output_Amps: 16.7 Proposed_Test_Date:: Rated_Output-_volts: 60 Rated_Output_Amps: 40 Rectifiercountry: 45640 RectifierLocation_City: Jackson Rectifier_address_additional: I mile east of Milton Twp. Road 167 Rectifier_County: Jackson Rectifier_GPS_N-: 39' 039" Rectifier_GPS_W-: 82' 267"

CC Case 10 – 2006 Comments_About_New_Case: This is an existing rectifier / groundbed that was replaced as it started to fail. Companies_Involved: AEP, COH* company: Tennessee Gas Pipeline Contact_Company: Tennessee Gas Pipeline Contact_E-mail: mailto:[email protected] Contact_Name: Dan Achauer Contact_Phone_#: 740-638-2101 ext 2029 email: [email protected] Ground_Bed_Type: Local name: Dan Achauer phone_no: 740-638-2101 ext 2029 Present_Output-_volts: 47.7 Present_Output_Amps: 11 Proposed_Test_Date:: Rated_Output-_volts: 60 Rated_Output_Amps: 30 Rectifiercountry: 45640 RectifierLocation_City: Jackson Rectifier_address_additional: Rectifier_County: Jackson Rectifier_GPS_N-: 39' 065" Rectifier_GPS_W-: 82' 275" Rectifier_Location: Jackson County Road 39 ( Mulga Road )

RECENTLY CLOSED CASES

CC- 02-2007- Closed Rectifier_Location: 10080 Shepard Rd. RectifierLocation_City: Macedonia Rectifiercountry: Rectifier_County: Summit Rectifier_GPS_N-: 41.348890 Rectifier_GPS_W-: 81.493802 Ground_Bed_Type: Local Rated_Output-_volts: 24 Rated_Output_Amps: 12 Present_Output-_volts: 15 Present_Output_Amps: 7.5 Contact_Name: Bob Schneider

11 Contact_Company: Dominion East Ohio Contact_Phone_#: 330-575-0351 Contact_E-mail: [email protected] Proposed_Test_Date:: Companies_Involved:: Comments_About_New_Case:

CC Case 07-2006 Closed Comments_About_New_Case: Replacement groundbed from local to deep well. Companies_Involved:: Buckeye*, COH*, Mid Valley, NORCO* company: Sunoco Logistics, Taylor, MI Contact_Company: Sunoco Logistics Contact_E-mail: mailto:[email protected] Contact_Name: Paul Love- new contact Contact_Phone_#: 313-600-5900 email: [email protected] Ground_Bed_Type: Deep Well name: Paul Love phone_no: 313-600-5900 Present_Output-_volts: 11.9 Present_Output_Amps: 8.5 Proposed_Test_Date:: Rated_Output-_volts: 30 Rated_Output_Amps: 16 Rectifiercountry: 43611 RectifierLocation_City: Toledo Rectifier_address_additional: Rectifier_County: Lucas Rectifier_GPS_N-: 41.6867166 Rectifier_GPS_W-: 83.4852333 Rectifier_Location: 3802 Summit St.

CC Case 08- 2006 Closed Comments_About_New_Case: Replacement groundbed from local to deep well. Companies_Involved:: Buckeye, COH*, Enbridge, NORCO company: Sunoco Logistics, Taylor, MI Contact_Company: Sunoco Logistics Contact_E-mail: [email protected] Contact_Name: Dan Ashley Contact_Phone_#: 313-600-5900 email: [email protected] Ground_Bed_Type: Deep Well name: Paul Love phone_no: 313-600-5900 Present_Output-_volts: 12.8 Present_Output_Amps: 9.7 Proposed_Test_Date:: Rated_Output-_volts: 30 Rated_Output_Amps: 16 Rectifiercountry: 43605 RectifierLocation_City: Toledo Rectifier_address_additional: Rectifier_County: Lucas Rectifier_GPS_N-: 41.65825 Rectifier_GPS_W-: 83.4918 Rectifier_Location: 2426 Consaul St.

CC Case 11 – 2006- Closed Comments_About_New_Case: Changed groundbed at tank 109 from perimeter to under tank system. Companies_Involved:: Buckeye*, Marathon* company: Mid Valley Pipeline Contact_Company: Mid Valley Contact_E-mail: [email protected] 12 Contact_Name: Vince Dalchuk Contact_Phone_#: 859-371-4469 email: mailto:[email protected] Ground_Bed_Type: Local name: Vince Dalchuk phone_no: 859-371-4469 Present_Output-_volts: 14 Present_Output_Amps: 7 Proposed_Test_Date:: 1/17/07 Rated_Output-_volts: Rated_Output_Amps: Rectifiercountry: RectifierLocation_City: Lima Rectifier_address_additional: Rectifier_County: Rectifier_GPS_N-: 40.708374 Rectifier_GPS_W-: 84.125482 Rectifier_Location: 985 W Buckeye Rd

Closed Cases 05-2005 name: Jeff Brown phone_no: 419-234-6095 email: mailto:[email protected] company: Buckeye Pipe Line Rectifier_Location: South of Old Millard BOC Gas (Buckeye Pipe Line ) property Rectifier_address_additional: RectifierLocation_City: Toledo Rectifiercountry: Rectifier_County: Lucas Rectifier_GPS_N-: Rectifier_GPS_W-: Ground_Bed_Type: Local Rated_Output-_volts: 50 Rated_Output_Amps: 30 Present_Output-_volts: Present_Output_Amps: Contact_Name: Jeff Brown Contact_Company: Buckeye Pipe Line Contact_Phone_#: 419-234-6095 Contact_E-mail: mailto:[email protected] Proposed_Test_Date:: will call Companies_Involved:: Marathon*, Sun*, Mid Valley, Enbridge Comments_About_New_Case: will be installing a 100' deepwell S/O Old Millard to protect 1-8" & 1-12" lines running between Sun & BP Refineries. Test Date 4-18-06

06-2005 Comments_About_New_Case: Replacement of existing groundbed. Current output remained unchanged. Test Date 5-3-06 Companies_Involved:: Buckeye company: Mid Valley Pipeline Contact_Company: Mid Valley Pipeline Contact_E-mail: mailto:[email protected] Contact_Name: Vince Dalchuk Contact_Phone_#: 859-371-4469 email: [email protected] Ground_Bed_Type: Distributed name: Vince Dalchuk phone_no: 859-371-4469 Present_Output-_volts: 10 Present_Output_Amps: 5 13 Proposed_Test_Date:: Call Rated_Output-_volts: 60 Rated_Output_Amps: 22 Rectifiercountry: 43413 RectifierLocation_City: Cygnet Rectifier_address_additional: Rectifier_County: Wood Rectifier_GPS_N-: Rectifier_GPS_W-: Rectifier_Location: 5152 Rock Ridge Rd

COMPANY INDEX

AEP American Electric Power ANR Trans Canada BP British Petroleum BUC Buckeye Partners CEI Cleveland Electric and Illuminating Company COH Columbia Gas of Ohio CPP Cleveland Public Power DEOG-T Dominion East Ohio Gas – Transmission DEOG-D Dominion East Ohio Gas – Distribution DTC Dominion Transmission Corporation MID Mid-Valley MPL Marathon Pipeline Company NCGT North Coast Gas Transmission NORCO Formally ARCO OGC Ohio Gas SUN Sunoco Logistics TCO Columbia Gas Transmission TETLP Texas Eastern Product Pipeline Company TGP Tennessee Eastern Transmission LP VEDO Vectren Energy Delivery Company