CO AC 4 505
GROWTH MEDIA STERILIZER
Contact: Carlyle CONN Contact: Philippe MIRA P - +1.814.362.2590 ext.322 T - 33(0) 450 83 12 12 F - +1.814.362.2574 F - 33(0) 450 83 12 10 E - [email protected] E - [email protected] Page 1/5
In order to meet your requirements and provide you with a quotation, we would be grateful if you could answer to the following questions. If you are interested in Liquid Biowaste decontamination or Embryo eggs Biowaste Decontamination, other questionnaires are available: CO AC 4 504 - Questionnaire - Liquid Biowaste Decontamination - ABC ACTINI CO AC 4 506 - Questionnaire - Embryo Eggs Biowaste Decontamination - ABC ACTINI
Many thanks.
COMPANY: Project Ref: Location: Date for the delivery of a quote: Estimated completion of the facility: Name of the contact:
GROWTH MEDIA STERILIZE
Maximal capacity of the sterilizer (contractual data): VERY IMPORTANT
Constant flow rate: Nominal production flow rate:
Variable flow: Nominal production flow rate (l/h): Maximal flow rate (l/h): Minimal flow rate (l/h):
Knowledge of the Product: Viscosity at 20°C in cp: Viscosity at 95°C in cp: Product sensitive above (°C): If you have other data at your disposal, please be kind to give us the temperatures and associated viscosities of the more viscous product of you product line.
Treatment scheme (*) Required F0: : or Required Time: Required Temperature: Process at constant F0 on variable flow rate? Yes No Inlet temperature (°C): Max. treatment temperature (°C): Max. holding time (s): Required outlet temperature (°C): * for the product with the above-mentioned characteristics. This case has to be the more restricting one for your production; it will allow to design the equipment
GMS – ABC ACTINI – REV1 CO AC 4 505
GROWTH MEDIA STERILIZER
Contact: Carlyle CONN Contact: Philippe MIRA P - +1.814.362.2590 ext.322 T - 33(0) 450 83 12 12 F - +1.814.362.2574 F - 33(0) 450 83 12 10 E - [email protected] E - [email protected] Page 2/5
Installation: Enclosed room Non-enclosed room Classification: Clean room
Cleaning in Place : Existing CIP? Yes No To quote? Yes No
Energies available on site: Steam: Flow rate: Pressure: Overheating water: Flow rate: Electricity: Power: Voltage: Cooling water: Flow rate: Temperature: Softened water: Flow rate: Temperature: Demineralised water Flow rate: Temperature: Compressed air Flow rate: Pressure:
Construction: Presence of chloride in the product: No Yes Concentration: (Information required to choose the type of stainless steel)
Required finishing for the stainless steel in contact with the product? - Without restraint: Ra 3,2 µ (Ra: 125 µ-inches) - Other: It’s compulsory to clarify the documentary aspect if an electro-burnishing is applied.
Raw finishing certification: - Issued by an external company: Extra cost will be charged for each element. - Issued by ABC ACTINI free of charge.
- 3.1.B (Extra cost for each component) - 2.2 (free of charge)
Welding control (percentage to precise) - Visual 20% 100% - Endoscopy with: photo video 20% 100% - Test with water under pressure: (less expensive than other controls) - Radiography 20% 100% - Dye penetrant test 20% 100% - Welding file to provide? Yes No - For what part of the process : - Percentage : %
GMS – ABC ACTINI – REV1 CO AC 4 505
GROWTH MEDIA STERILIZER
Contact: Carlyle CONN Contact: Philippe MIRA P - +1.814.362.2590 ext.322 T - 33(0) 450 83 12 12 F - +1.814.362.2574 F - 33(0) 450 83 12 10 E - [email protected] E - [email protected] Page 3/5
GMS – ABC ACTINI – REV1 CO AC 4 505
GROWTH MEDIA STERILIZER
Contact: Carlyle CONN Contact: Philippe MIRA P - +1.814.362.2590 ext.322 T - 33(0) 450 83 12 12 F - +1.814.362.2574 F - 33(0) 450 83 12 10 E - [email protected] E - [email protected] Page 4/5
Instrumentation: Type of the flowmeter: - Electromagnetic flowmeter - Mass flowmeter (in case of demineralised water)
Required Raw finishing certification: Yes No - 3.1.B (Extra cost for each component) - 2.2 (free of charge)
Automation: PLC or SCC (centralized control system) supplied by others
Our standards: SIEMENS S 7 ALLEN BRADLEY Control Logix
PLC located: on the skid somewhere else Information to forward to the supervisor PLC or to the Building Management System If yes: - Interactive mode - 0/1 information - Exchange table - Communication network type: Functional Analysis according to S88 Yes No
Equipment qualifications and documentation : Complete pharmaceutical Documentation Assistance to the qualifications IQ (Installation Qualifications) OQ (Operating Qualifications) PQ (Performance Qualifications)
Pricing basis to take into consideration: IQ + OQ + PQ = 20% to 30% of the budget The assistance consists in producing FAT and SAT tests and protocols, together with the machine documentation to help to the equipment qualification.
Items to include in our quotation: Shipment and insurance Yes No Unloading Yes No Installation Yes No
N.B: We do not usually supply the energy connection and piping.
GMS – ABC ACTINI – REV1 CO AC 4 505
GROWTH MEDIA STERILIZER
Contact: Carlyle CONN Contact: Philippe MIRA P - +1.814.362.2590 ext.322 T - 33(0) 450 83 12 12 F - +1.814.362.2574 F - 33(0) 450 83 12 10 E - [email protected] E - [email protected] Page 5/5
Available space in the room: Length (mm): Width (mm): Height (mm):
Description of the process :
Comments :
GMS – ABC ACTINI – REV1