ICYNENE TECHNICAL PRODUCT DATA

Icynene Classic Plus™ (LD-C-70)

THERMAL INSULATION AND AIR BARRIER ACOUSTICAL PROPERTIES CCMC 13864-R  Performance in a 38 x 89 mm (2 x 4”) wood stud wall: Specification Sections: 07 21 19 Foamed-in-Place Insulation, 07 27 00 Spray Polyurethane Foam Air STC Sound Transmission Class - 37 Barriers Hertz Frequency 125 250 500 1000 2000 4000 ASTM E 9 0 1 9 3 0 3 1 4 2 3 8 4 6 PRODUCT DESCRIPTION NRC Noise Reduction Coeff. - .70 TM Classic Plus is a spray-in-place low density, open Hertz Frequency 125 250 500 1000 2000 4000 celled, flexible, 100% water-blown polyurethane foam ASTM C 423 .11 . 43 .89 .72 .71 .67 insulation manufactured by Icynene Inc. ICYNENE TM 3 3 Classic Plus is a nominal 11 kg/m (0.7 lbs/ft ) density, AIR BARRIER/ MECHANICAL VENTILATION free rise material. The product is for use as a thermal  ICYNENE Classic PlusTM fills any shaped insulation and air barrier in: cavity, and adheres to most construction  wall cavities materials, creating assemblies with very low air  floors separating living spaces from a garage permeance.  cathedral ceiling assemblies  Additional interior or exterior air infiltration  overhanging floor assemblies protection is subject to applicable codes.  interior below-grade foundation walls  All buildings insulated and air sealed with ICYNENE Classic PlusTM must be designed to PROPERTIES OF CURED FOAM include adequate mechanical ventilation/outdoor air supply. Test Value Metric  For mechanical ventilation see CAN/CSA F-326 - Characteristic Method (Imperial) Residential Mechanical Ventilation, HRAI (Heating, Core Density ASTM 11.2 kg/m³ Refrigeration and Air Conditioning Institute of D 1622 (0.7 lb/ft³) Canada) Digest, ASHRAE (American Society of Colour Yellow Heating, Refrigeration and Air-Conditioning Thermal Resistance 0.72 (m²·K)/W Engineers) guidelines, or any other acceptable at 25.4 mm (R-4.1 at 1") good engineering practice. Air Permeance at ASTM 0.019 L/s.m² 50.8 mm E 2178 WATER ABSORPTION PROPERTIES Water Vapor ASTM 1626 ng/Pa.s.m²  Water can be forced into the foam under pressure Permeance at 25 mm E 96 (28 perm at 1") because it is open celled. Dimensional Stability -0.2% at -29°C  Water will drain by gravity, given favourable at 28 days (Volume ASTM D -3.5% at 80°C drying potential, and upon drying all chemical Change) 2126 -0.8% at 70°C and physical properties are fully restored. and 97% RH Surface Flame CAN/ULC- 415 BURN CHARACTERISTICS Spread Rating 127  ICYNENE Classic PlusTM is a combustible Smoke Developed CAN/ULC- 110 product and is therefore, consumed by flame, Classification 102 but will not sustain flame upon removal of the Time to Occupancy(1) CAN/ULC- 24 Hours flame source. It leaves a charred foam residue. S774 It will not melt or drip. Fungus Testing ASTM TM No Growth  ICYNENE Classic Plus is subject to all C 1338 applicable National and/or Provincial building

(1) codes regarding fire prevention. Requirements The volatile organic compound (VOC) emissions under for Thermal Barrier coverings must be met as consideration were measured with an assumed room per the applicable building code having ventilation rate of 0.3 air changes per hour as per jurisdiction. the NBC 2010 requirements for new construction.

ICYNENE Classic Plus™ - Technical Product Data Canada ICYNENE TECHNICAL PRODUCT DATA

 Within seconds, the foaming process is complete.

ELECTRICAL WIRING  ICYNENE Classic PlusTM has been evaluated with energized 14/3 and 12/2 residential wiring (max. AVAILABILITY 50°C/122°F). Contact Icynene Inc. at 800-758-7325 or visit our website  It is chemically compatible with typical electrical at www.Icynene.com. wiring coverings.  For any insulation of older knob and tube wiring, WARRANTY please reference local electrical code. WHEN INSTALLED PROPERLY IN ACCORDANCE WITH INSTRUCTIONS, THE COMPANY CORROSION WARRANTS THAT THE PROPERTIES OF THE  ICYNENE Classic PlusTM did not cause corrosion PRODUCT MEET PRODUCT SPECIFICATIONS AS when evaluated in contact with steel at 48ºC OUTLINED IN THIS TECHNICAL DATA SHEET. (120ºF) and 85% relative humidity conditions. SAVE AND EXCEPT ANY EXCLUSIONS REFERENCED IN THE WARRANTY. PLASTIC PIPING  ICYNENE Classic PlusTM is compatible in TECHNICAL direct contact with the following piping systems, as Icynene Licensed Dealers and Icynene Inc. provide per Paschal Engineering Study: support on both technical and regulatory issues. o CPVC Architectural specifications in CSC 3-Part format and o ABS design details are available at our website at o PVC www.icynene.com. o PP-R REGULATORY TM ENVIRONMENTAL/HEALTH/SAFETY ICYNENE Classic Plus has been independently  ICYNENE Classic PlusTM is 100% water- evaluated by the Canadian Construction Materials blown and therefore contains no ozone-depleting Centre (CCMC). For regulatory issues concerning TM blowing agents. Classic Plus in Canada, please see CCMC Evaluation  The reaction used to create ICYNENE Classic Report 13864 -R, The NBCC (National Building Code PlusTM generates carbon dioxide to expand the of Canada) or applicable Provincial Building Codes. foam. Carbon dioxide has a very low Global Warming Potential (GWP of 1). RELATED REFERENCES  ICYNENE Classic PlusTM is PBDE-free. All physical properties were determined through testing by accredited third party agencies. Icynene Inc. reserves  It has been thoroughly evaluated for in-situ the right to change specifications in its effort of emissions by industry and government experts. continuous improvement. Please confirm that technical  Proper handling and use is required to avoid data literature is current. exposure to reactive chemicals in their unreacted state. PACKAGING AND STORAGE  Not intended for exterior use. Not to be  Packaging - 55 US gallon, closed top steel drums installed within 76 mm (3”) of heat emitting devices º  Component ‘A’ – 550 lb. per drum. Base Seal® or where the temperature is in excess of 82 C MDI (180°F), as per ASTM C411 or in accordance with  Component ‘B’ – 500 lb. per drum. ICYNENE applicable codes. Classic PlusTM – Resin

INSTALLATION  ICYNENE Classic PlusTM (Component A) and TM  ICYNENE Classic Plus is installed by a network (Component B) ideally should be stored between of Licensed Dealers, trained in its installation. 15°C (60ºF) and 29°C (85ºF).  Installation is generally independent of  Component A should be protected from freezing. environmental conditions.  It can be installed in hot, humid or freezing conditions.  Surface preparation is generally not necessary.