FLEX800 Series Sprinklers-FLX35 Dual

Total Page:16

File Type:pdf, Size:1020Kb

FLEX800 Series Sprinklers-FLX35 Dual

FLEX800TM Series Sprinklers FLX35 – Dual Trajectory

Specifications . 2.89 lbs. (1,3 kg) sprinkler will rotate uni-directionally in the  Radius: 43’–83’ (13,1–25,3m) . 3.58 lbs. (1,6 kg) Integrated GDC clockwise direction. The sprinkler shall be  Flow rate: 8.2–47.3 GPM (31–179 LPM) Module adjustable wet or dry, by hand, and using  Arc: Bidirectional, part circle rotation,  Three inline nozzles; rotating stream no tools. The arc adjustment band shall adjustable from 40-330, and true pattern identify the 90, 180, 270 and 360 arc positions. The end-of-arc dwell time shall unidirectional 360 full-Circle rotation.  Precipitation rates: . Minimum: 0.43”/hr. (10,9mm/hr.) not exceed 2 seconds and will generally be  Pilot Valve-selectable at 50, 65, 80 or . Maximum: 0.76”/hr. less than 1 second. 100 psi (3,5, 4,5, 5,5 and 6,9 Bar) (19,3mm/hr.)  Recommended operating pressure range:  Main nozzles: 8 (30, 31, 32, 33, 34, 35, Rotation shall be accomplished by a water- 65–100 psi (4,5–6,9 Bar) 36 and 37) lubricated compound cluster gear drive  Maximum pressure: 150 psi (10,3 Bar)  Selectable nozzle trajectory: 15 or 25 with balanced reversing gear plate. The  Minimum pressure: 40 psi (2,8 Bar)  Apex and Radius: drive assembly shall be driven by a spring-  Activation types – Electric Valve-in- 15° 25° loaded, poppet-type variable stator, sized to Head: provide 3-minute, full-circle rotation Standard Solenoid: 65 psi (4,5 Bar) - 31 – 6’(1,8m)@51’(15,5m) 13’(4,0m)@54’(16,4m) speeds throughout the pressure range. The . 24 VAC, 50/60 Hz 32 – 6’(1,8m)@51’(15,5m) 11’(3,4m)@64’(19,5m) drive and stator assemblies shall be . Inrush: 0.30 A 33 – 7’(2,1m)@59’(18m) 13’(4,0m)@68’(16,5m) constructed of corrosion-proof plastic and . Holding 0.20 A 34 – 8’(2,4m)@63’(19m) 15’(4,6m)@74’(22,6m) stainless-steel components. - Spike Guard Solenoid: 35 – 9’(2,7m)@66’(20m) 15’(4,6m)@76’(23m) . 24 VAC, 50/60 Hz 80 psi (5,5 Bar) The sprinkler shall include a nozzle base . Inrush: 0.12 A 36 – 8’(2,4m)@75’(22,9m) 18’(5,5m)@83’(25,3m) 37 – 9’(2,7m)@74’(22,5m) 19’(5,8m)@82’(25m) clutching feature that allows the user to . Holding 0.10 A rotate the nozzle base in either direction, - Nickel-Plated Spike Guard Solenoid: wet or dry, and hold in one position during . 24 VAC, 50/60 Hz Bidding Specifications operation to allow for spot watering. . Inrush: 0.12 A . Holding 0.10 A The sprinkler shall be capable of full- and Water distribution shall be via three - DC Latching Solenoid (DCLS): part–circle operation, and be a gear-driven nozzles mounted in a 2¼”-diameter . Momentary low voltage pulse rotary type. The sprinkler shall include a (57mm) plastic nozzle turret. The three - Integrated GDC Module w/DCLS: ratcheting riser feature that allows the user nozzles shall be oriented in the same . Momentary low voltage pulse to adjust the position of the riser in the direction and elevate 3¼” (83mm) above  Stator variations: 3 body without disassembly. The arc of the the body when in operation. All of the  Inlet size: 1” (25mm) ACME sprinkler shall be adjustable by the use of sprinkler nozzles shall be of a thread-in  Body height: 10” (254mm) an adjustment band located between the type accessible from the front with no other  Body flange diameter: 6 ½” (165mm) nozzle base and riser. The left terminus of disassembly required. All nozzles are the arc shall be fixed with the right position  Pop-up height to nozzle: 3¼” (83mm) color-coded for easy identification of adjustable from a 40 arc minimum up to a radius and gallonage performance  Pop-up height (overall): 43/ ” (106mm) 16 360 arc maximum. When the 360 arc capabilities and shall be designed to allow  Weight: adjustment position is reached, the any particle capable of passing through the October, 2014 FLEX800TM Series Sprinklers FLX35 – Dual Trajectory riser screen to pass through the nozzle. assembly shall be stamped with the is generally used with a GDC module that The sprinkler shall be capable of accepting manufactured date. is remotely located. a fourth and fifth nozzle that can be installed 180 from the main nozzle to The sprinkler shall incorporate an electrical Integrated GDC Module provide coverage behind the sprinkler. solenoid for activation of the integrated The Integrated GDC Module activation These back nozzle positions shall be control valve in one of five activation types type incorporates the GDC module manufactured with a factory-installed plug as described below. attached to the outside of the sprinkler that can be removed to accept over 100 body and includes a DC latching solenoid different inner and intermediate nozzle for activation of the control valve. The DC combinations. The sprinkler shall be latching solenoid shall be activated by the capable of accepting 7 different color- Integrated GDC module with a momentary coded main nozzles, a main nozzle plug, a low voltage pulse that moves the plunger main nozzle adapter, and 10 different Standard Solenoid from the “OFF” position to the “ON” color-coded inner/intermediate nozzles. The Standard solenoid shall be suitable for position where it is maintained by a 24 VAC, 50/60 Hz service with an inrush permanent magnet in the solenoid. To The main nozzle shall incorporate a current of 0.30 A @ 50/60 Hz, and holding deactivate, a second momentary low-volt selectable adjustment that provides main current of 0.20 A @ 50/60 Hz and shall be pulse is applied to move the plunger from nozzle discharge angle adjustment at 15° capable of withstanding a voltage surge of the “ON” position to the “OFF” position. and 25°. Close-in watering distribution up to 9k volts in the common and normal shall be achieved by a patented helical modes without failure. The internal valve assembly shall be a restrictor inserted into the inner nozzle and piston-type that vents to the atmosphere, shall be capable of adjusting the Spike Guard Solenoid providing valve friction loss of less than 5 distribution profile to optimize uniformity. The Spike Guard solenoid shall be suitable psi (0,34 Bar). The sprinkler shall be An optional radius reduction screw can be for 24 VAC, 50/60 Hz service with an designed to provide smooth valve closure installed to break up the main nozzle inrush current of 0.12 A @ 50/60 Hz, and in excess of two seconds to minimize stream. The cap shall identify the installed holding current of 0.10 A @ 50/60 Hz. and damage resulting from surges and water main nozzle size and the date of shall be capable of withstanding a voltage hammer. All valve seals shall be manufacture. surge of up to 20k volts in the common and constructed of natural rubber. The valve normal modes without failure. seat seal shall be constructed of fabric- The pilot valve assembly shall incorporate reinforced natural rubber. The electric one of five electrical activation types Nickel-Plated Spike Guard Solenoid valve assembly shall incorporate a 100- (described below) to control the ON-OFF The Nickel-Plated Spike Guard solenoid mesh stainless-steel screen for the control operation of the sprinkler. It shall provide shall be suitable for 24 VAC, 50/60 Hz water, preventing entry of foreign materials four pressure-point selections (50, 65, 80 service with inrush current of 0.12 A @ into the pilot valve assembly. and 100 psi; 3,5, 4,5, 5,5 and 6,9 Bar), with 50/60 Hz, and holding current of 0.10 A @ a vandal-resistant locking feature that 50/60 Hz. and shall be capable of The sprinkler body and cap shall be ensures the desired setting is maintained. withstanding a voltage surge of up to 20k injection-molded from ABS – a corrosion- The pressure points shall be graphically volts in the common and normal modes proof, impact-resistant, UV-resistant, illustrated in psi and kg/cm2. The pilot without failure. It shall also have a nickel- heavy-duty, engineering-grade plastic valve assembly shall include a pressure- plated core to provide additional corrosion- material. The cap and nozzle base shall regulation feature that continuously resistance in potable and non-potable water incorporate a pull-up feature that provides monitors the operating pressure inside the applications. improved serviceability of nozzles and sprinkler body, making the necessary riser. The sprinkler shall have two plastic adjustments to ensure the desired and set DC Latching Solenoid filter screens – a top-serviceable coarse regulation pressure is maintained. The The DC latching solenoid shall be rock screen in the body inlet sized to pilot valve assembly shall incorporate a activated by a momentary low-voltage prevent entry of larger foreign material manual control feature that is accessible pulse that moves the plunger from the from entering the body, and a finer screen from the top and allows the sprinkler to be “OFF” to the “ON” position where it is threaded into the riser, sized to prevent manually selected “ON”, “OFF” or placed maintained by a permanent magnet in the foreign material from clogging the nozzle. in the “AUTO” position awaiting solenoid. To deactivate, a second commands from the control device. The momentary low-volt pulse is applied to The sprinkler shall have a riser/body seal manual selector shall be red in color for move the plunger from the “ON” position assembly that regulates flushing during enhanced visibility. The pilot valve to the “OFF” position. This activation type pop-up and retraction to clear any debris from around the riser, and a heavy-duty,

October, 2014 FLEX800TM Series Sprinklers FLX35 – Dual Trajectory stainless-steel spring to ensure positive retraction. The riser is sealed by a durable, FLX35 sprinklers are engineered to over-molded urethane ring on the seal provide a smooth, consistent curtain of retainer. Sprinkler flush rate shall not water across the arc, with provision made exceed 5 GPM (18,9 LPM). for head-to-head coverage. For proper spacing, ensure that system design and The sprinkler shall be capable of installation accounts for prevailing wind identifying the use of effluent water via a conditions and body cover angle-to-grade. lavender-colored marking. The sprinkler cap shall indicate model designation, It is recommended that sprinklers are nozzle number and manufacturing date installed 2” (5cm) from hardscaping and code. 6”-12” (15,2-30,5cm) from buildings or other vertical impediments to allow for The sprinkler shall be of a pop-up design normal maintenance procedures and to with an overall height of 10” (254mm), a minimize overspray on buildings. Where body flange diameter of 6 ½” (165mm), a possible, sprinkler heads should be cap diameter of 3 3/8” (85mm) and a pop- installed in a manner that will minimize up stroke of 4 3/16” (106mm). The nozzle stream contact with trees, controller sprinkler shall have a 1” (25mm) ACME enclosures, shrubbery or other obstructions. female-threaded inlet. The sprinkler shall be capable of covering ___ feet radius at ___ pounds per square inch pressure with a discharge rate of ___ gallons per minute.

The sprinkler shall be developed and manufactured by an ISO 9001-certified facility. The sprinkler shall be model number ______and shall be manufactured by The Toro Company, Irrigation Division.

Recommended Installation Procedures The FLX35 sprinkler is designed specifically for turf areas requiring _____ coverage. These products offer the most economical method of irrigation where flows and system pressures are available to support a greater radius.

The FLX35 sprinkler should be specified for installation on a Toro swing joint. The swing joint should be specified as a triple- swing type, allowing movement up, down, laterally and at an angle-to-grade. The sprinkler should be installed with the body cover at grade.

Individual sprinkler head control is accomplished using a single FLX35 valve- in-head sprinkler per controller station. Use of the valve-in-head model will allow individual station control, and is particularly useful for irrigating distinct turf regions at unique application rates.

October, 2014

Recommended publications