QuadTech 1910/1920 1 MHz LCR Meter Estimated Delivery: 2 to 4 weeks This is a series made up of a number of models. To find your specific model either click SHOW ALL Button or use the Filters Boxes, below. Then Request a Repair or Calibration Quote select the model by clicking the model number (blue text in table). Request Technical Support Reset Show All Email to a Friend Print Page Internal Bias Accessories 20 Hz to 1 MHz Frequency Range (27,000 Possible Test Frequencies) 0.1% Basic Measurement Accuracy Measures 15 Impedance Parameters, DC Resistance, and Current Wide Measurement Range with 5 Digit Measurement Resolution Four-terminal Kelvin connections to maintain measurement integrity MORE VIEWS AC Test Voltage Programmable from 20 mV to 1V 1910 Internal DC Bias Current, Programmable from 0 to 1A 1920 Internal DC Bias Voltage, Programmable from 0 to 2 V IEEE-488.2,RS-232, handler, and serial printer interfaces all standard CE Marked Photo represents example of series. See datasheet for more details on any specific The 1910 Analyzer is designed to perform inductance and impedance model. measurements on coils and wire wound devices over a frequency range from 20Hz to 1MHz.

The 1920 1 MHz LCR Meter is designed to perform and impedance Data Sheet measurements on a variety of electronic components and materials over a frequency Manuals range from 20Hz to 1MHz. For both units, emphasis has been placed on ease of use Options / Accessories through menu programming, and fast accurate production testing via its remote control Application Notes capability.

ALSO CONSIDER 15 Different Impedance Parameters/20 Total Parameters Measure and display any two GenRad 1692 parameters simultaneously, to achieve coverage Benchtop LCR and flexibility not previously available. Meter Automatic Test Sequencing Run up to six different tests in sequence with a single push of the start button. Each test can have different conditions and limits. Program and Data Storage Test setups can be stored and recalled from internal memory. The front panel can be locked out, with password protection, to ensure procedures are run the same way every time. QuadTech 7600 Load Correction Substantially improves instrument accuracy by performing Plus Precision LCR measurements on a known standard and applying correction to subsequent Meter measurements. Ideal for repetitive testing of identical devices at like test conditions. Why Buy? For a wide frequency range (to 1MHz) at an affordable price When both AC impedance and DC resistance measurements are needed For automated production testing using RS232, IEEE-488 & PLC interfaces When internal bias current is required for testing coils and inductors GenRad 1840-A Output Power Meter Configure instrument and log results to PC using the 1900 Virtual Front Panel

1910/1920 Inductance Analyzer Basic Specifications Measured Parameters and Basic Measurment Accuracy:

Parameter Measurement Range Fast Medium Slow

Ls,Lp 0.001 nH to 99.999 H +/-0.5% +/-0.25% +/-0.1%

Cs,Cp 1 pF to 9.9999 F +/-0.5% +/-0.25% +/-0.1%

DF 0.00001 to 99.999 +/-0.005 +/-0.0025 +/-0.001

Q 0.00000 to 9999.9 +/-0.005 +/-0.0025 +/-0.001

Y,Gp,Bp 10 nS to 9999.9 S +/-0.005 +/-0.0025 +/-0.001

|Z|,Rs,Rp,Xs,ESR 0.0001 m! to 99.999 M! +/-0.5% +/-0.25% +/-0.1% Phase Angle -180.00 to +179.99 degrees +/-1.8° +/-0.9° +/-0.18°

DCR 0.1 mVto 100 KV +/-0.5% +/-0.25% +/-0.1%

DUT AC Voltage 20 mV to 1.0 V +/-0.5% +/-0.25% +/-0.1%

DUT AC Current 1 µA to 150 mA +/-0.5% +/-0.25% +/-0.1%

DUT DC Voltage 20 mV to 1.0 V +/-0.5% +/-0.25% +/-0.1%

DUT DC Current 1 µA to 150 mA +/-0.5% +/-0.25% +/-0.1%

*At optimum test signal levels, frequencies, DUT values and without calibration uncertainty. Capacitance (Cs/Cp), Inductance (Ls/Lp), Resistance (Rs/Rp), Dissipation (D) and Quality (Q) Factors, Impedance Z , Admittance Y , Phase Angle (0-), Equivalent Series Resistance (ESR), Conductance (Gp), Reactance (Xs), Susceptance (Bp) Note: s = series, p = parallel, ESR equivalent to Rs Test Frequency Range: 20Hz to 1MHz, Continuous Test Frequency Resolution: 1Hz from 20Hz to 1KHZ, 4 digits >1KHZ Test Frequency Accuracy: +/- (0.01% +0.02 Hz) Measurement Speed: Fast: 40 meas/sec Medium: 8 meas/sec Slow 1 meas/sec Ranging Automatic,Range Hold or user selectable Trigger internal (automatic) External(via RS-232,IEEE-488.2 or Handler interfaces Manual Source Impedance 5V, 25V, 50V, 100V, or matched impedance, range dependent AC Test Signal Voltage: 20mV to 1.0V (open circuit) in 5 mV steps DC Bias Current Internal: 0.0 to 1.0A in 1mA steps External: up to 20.0A Standard Interfaces IEEE-488.2 • RS-232 • Handler • Serial Printer Measurement Delay Programmable from 0 to 1000 ms in 1ms steps Averaging Programmable from 1 to 1000 Median Value Averaged over last three measurements Built-in automatic calibration procedure Test Terminals Front panel, four terminal (BNC) Optional Test Fixtures Available Dimensions: 17x 5.25x 16in (432x 133x 406 mm) Weight: 15lbs (8kg) net, 21lbs (9.9kg) shipped

ACCESSORIES

NIST Traceable Calibration Cert ISO-17025 Accredited Calibration with 1910/1920 Application Wizard with RS- (Included) Test Data 232 Cable

1689-9600 Remote Test Fixture 1700-03 Kelvin Test Leads 7000-04 Alligator Clip Leads, 1 Meter

1689-9602 BNC-BNC Extender Cable 1689-9602-2 Meter BNC-BNC Extender 7000-05 Chip Component Tweezers Cable 2000-16 Rack Mount Kit for 1910/1920 Rigid Dielectric Cell LD-03 High Temperature Rigid Dielectric Cell LD-3T

Liquid Dielectric Cell 350G Powder and Paste Cell MC-100