Proposal for: Goddard, KS SPLASH PAD

Presented by: Amy Altman Aquatic Recreation Co. 952.345.6440 [email protected]

Proposal #16332–4 November, 2016

Aquatic Recreation Company Now a part of

952.445.5135 | 877.632.0503 | www.arc4waterplay.com 2

Thank you for the opportunity

Thank you for this opportunity to submit our response to the referenced request for proposal. Enclosed you’ll find detailed descriptions of the extensive level of services by Aquatic Recreation Company (ARC).

In addition, we are providing a conceptual 3d design with supporting product information and a products and services proposal. Contents Understanding that you may be in the very initial design concept stages and that the project DESIGN CONCEPTS may evolve, please note the following qualifications of ARC’s proposal:

PRODUCT SELECTION •The enclosed design is an initial concept and has been designed in order to fit the space and types of features indicated in the request for proposal. MECHANICAL OVERVIEW •ARC’s project design is to be a single pass system. EQUIPMENT & SERVICES •ARC’s mechanical components to be housed above ground in a housing or equipment room provided by others. SPECIFICATIONS

Please let me know if I may assist you further as I look forward to hearing from you!

Sincerely, Amy Altman Sales Manager Direct: 952-345-6440 Email: [email protected]

Aquatic Recreation Company 3

And we make water fun. From large-volume water features to ARC-tistic structures, we do more with your water and always keep fun at a premium.

Big fun, big value Our splash pad structures and ground sprays are designed are for kids young and old. We understand that play value for little kids is just as important as durable structures, flexible product options and dollar-for- dollar value are to “big” kids.

Waterplay ARChitects Like any good architect, we aim for long-lasting value. That’s why we engineer our splash pads with prefabricated, top-of-the-line mechanical systems that offer years of reliable, easy-to-use operation.

Passion, experience and dedication With over 25 years in the water entertainment business, you might say that we live and breath water (but without gills). We enjoy sharing our passion with our customers—it’s what drives us to provide hands-on service and go the extra mile with our concept and construction design services.

Aquatic Recreation Company www.arc4waterplay.com DESIGN CONCEPT 4 PRODUCT SELECTION MECHANICAL OVERVIEW EQUIPMENT & SERVICES Front view for: Goddard, KS SPLASH PAD SPECIFICATIONS

*Custom Aim N Sprays to be theme painted to resemble logos pictured below.

*

*

*All products are shown as conceptual only.

Aquatic Recreation Company www.arc4waterplay.com DESIGN CONCEPT 5 PRODUCT SELECTION MECHANICAL OVERVIEW EQUIPMENT & SERVICES Overhead view for: Goddard, KS SPLASH PAD SPECIFICATIONS

Overall pad dimensions: 39’ 8” X 42’ 2”

A Mega Water Bucket @ 10 gpm

A B Shower Water Dome @ 5 gpm

C (2) Custom Aim N Spray @ 5 gpm

D Rotating Water Arch Bar @ 15 gpm I I E Rotating Mister @ 8 gpm

D F Sit N Soaker @ 15 gpm F G Water Tent @ 15 gpm

39 FT K H (2) Water Bug @ 10 gpm 8 IN C H K I (2) Junior Geyser @ 10 gpm J K M J Curvy Jet Manifold @ 8 gpm

G E K (6) Stream Jet @ 1 gpm L K L Bubbler @ 10 gpm

K K M Activation Bollard B H C

5’ Concrete Total system Flow Rate: 142 GPM Apron

42 FT 2 IN

Aquatic Recreation Company www.arc4waterplay.com DESIGN CONCEPT 6 PRODUCT SELECTION MECHANICAL OVERVIEW EQUIPMENT & SERVICES Front view for: Goddard, KS SPLASH PAD SPECIFICATIONS

*All products are shown as conceptual only.

Aquatic Recreation Company www.arc4waterplay.com DESIGN CONCEPT 7 PRODUCT SELECTION MECHANICAL OVERVIEW EQUIPMENT & SERVICES Front view for: Goddard, KS SPLASH PAD SPECIFICATIONS

*All products are shown as conceptual only.

Aquatic Recreation Company www.arc4waterplay.com DESIGN CONCEPT PRODUCT SELECTION 8 MECHANICAL OVERVIEW EQUIPMENT & SERVICES SPECIFICATIONS

Mega Water Bucket Shower Water Dome

The Mega Water Bucket The Shower Dome is a is a 18’ 4” structure that structure that emits a water randomly dumps a generous effect from the top of a 5’ 6” amount of water from a very diameter dome that spreads large tipping bucket onto the out around the perimeter and Maximum flow 20 GPM 75.71 LPM platform roof, splashing out falls to users below. only users below. Flow Range 10 to 20 GPM Standard flow 10 GPM 37.85 to 75.70 LPM 37.85 LPM Size 18’ 4” x 8’ 2” x 5’ 4” Minimum flow 5 GPM 5.61 x 2.48 x 1.62 m 18.93 LPM Splash zone 20’ 0” x 35’ 0” Size 9’ 6” x 5’ 6” 6.10 x 10.67 m 2.92 x 1.71 m Splash zone 15’ 0” Diameter 4.57 m Diameter

Aquatic Recreation Company www.arc4waterplay.com DESIGN CONCEPT PRODUCT SELECTION 9 MECHANICAL OVERVIEW EQUIPMENT & SERVICES SPECIFICATIONS

Custom Aim N Rotating Water Spray Arch Bar

The Custom Aim N Spray The Rotating Water Arch is an interactive structure Bar is a structure that emits that emits a single stream of multiple streams of water from water from the 14” rotating a low horizontal cross bar. head spray on the top of the Users can rotate cross bar 160 GPM Maximum flow 605.66 LPM feature. 360 degrees to create unique Flow Range 5 GPM water patterns. 80 GPM 18.93 LPM Standard flow 302.83 LPM

Size 3’ 0” x 0’ 12” 15 GPM .91 x .30 m Minimum flow 56.78 LPM

Splash zone 15’ 0” Radius 6’ 0” x 4’ 0” 4.57 m Radius Size 1.83 x 1.22 m

10’ 0” x 10’ 0” Splash zone 3.05 x 3.05 m

Aquatic Recreation Company www.arc4waterplay.com DESIGN CONCEPT PRODUCT SELECTION 10 MECHANICAL OVERVIEW EQUIPMENT & SERVICES SPECIFICATIONS

Rotating Mister Sit N Soaker

The Rotating Mister is an The Sit N Soaker is a interactive spray feature that structure that emits multiple emits multiple misting effects arching streams of water from from a rotating head that the top of the bench back up, swivels left and right. over and onto users seated on the bench. Flow Range 8 to 10 GPM Flow Range 15 to 30 GPM 30.28 to 37.85 LPM 56.78 to 113.56 LPM Size 3’ 4” x 0’ 8” Size 5’ 0” x 2’ 6” 1.01 x .203 m 1.52 x .79 m Splash zone 12’ 0” Splash zone 10’ 0” x 8’ 0” 3.66 m Diameter 3.05 x 2.44 m

Aquatic Recreation Company www.arc4waterplay.com DESIGN CONCEPT PRODUCT SELECTION 11 MECHANICAL OVERVIEW EQUIPMENT & SERVICES SPECIFICATIONS

Water Tent Water Bug

The Water Tent is a The Water Bug is a structure structure that emits a “tent that emits two streams of like” sheet of water from it’s water at an angle from a 12” top onto users. diameter cap.

Flow Range 15 to 30 GPM Flow Range 10 to 20 GPM 56.78 x 113.56 LPM 37.85 to 75.71 LPM Size 4’ 0” x 0’ 6” Size 0’ 6” x 1’ 0” 1.22 x .15 m .18 x .30 m 8’ 0” x 6’ 0” Splash zone 10’ 0” Diameter Splash zone 2.44 x 1.83 m 3.05 m Diameter

Aquatic Recreation Company www.arc4waterplay.com DESIGN CONCEPT PRODUCT SELECTION 12 MECHANICAL OVERVIEW EQUIPMENT & SERVICES SPECIFICATIONS

Junior Geyser Curvy Jet Manifold

The Junior Geyser is a The Curvy Jet Manifold ground spray element that is a ground spray element emits a medium bodied, that emits eight (8) clear aerated mound of water. streams of water, creating Maximum flow 80 GPM The feature flow rates can a curved formation. Users 302.83 LPM be adjusted to increase can work together to plug 10 to 15 GPM Standard flow 40 GPM or decrease geyser height Flow Range holes and create larger 37.85 to 56.78 LPM 151.42 LPM water flow through the and volume. The Junior 8 GPM Size 3’ 0” x 0’ 9” Minimum flow Geyser is designed for wet unplugged holes. 30.28 LPM .91 x .27 m deck applications with no 4’ 0” x 8’ 0” x 5’ 0” Splash zone 8’ 0” Diameter Size 1.22 x 2.44 x 1.52 m standing water. 2.44 m Diameter Splash zone 12’ 0” x 8’ 0”

3.66 x 2.44 m

Aquatic Recreation Company www.arc4waterplay.com DESIGN CONCEPT PRODUCT SELECTION 13 MECHANICAL OVERVIEW EQUIPMENT & SERVICES SPECIFICATIONS

Stream Jet Bubbler

The Stream Jet is a ground The Bubbler is a ground spray element that emits spray element that emits a single stream of water a low foaming mound of upward. The feature flow water. The feature flow 10 GPM rates can be adjusted to Maximum flow rates can be adjusted to Maximum flow 20 GPM 37.85 LPM 75. 71 LPM increase or decrease the increase or decrease bubbler Standard flow 5 GPM spray height. The Stream height and volume. The Standard flow 10 GPM 18.93 LPM 37.85 LPM Jet is designed for wet Bubbler is designed for wet Minimum flow 1 GPM — — — deck applications with no deck applications with no Minimum flow 3.78 LPM standing water. 5’ 0” x 0” 3” standing water. Size Size Will Vary with Flow 1.52 x .09 m

Splash zone 8’ 0” Diameter Splash zone 3’ 0” Diameter 2.44 m Diameter .91 m Diameter

Aquatic Recreation Company www.arc4waterplay.com DESIGN CONCEPT PRODUCT SELECTION MECHANICAL OVERVIEW 14 EQUIPMENT & SERVICES Mechanical overview for: Goddard, KS SPLASH PAD SPECIFICATIONS

ARC City Water System Overview System type: ARC’s city water systems are an alternative to recirculation systems when splash pads are in a controlled environment with limited usage times or when systems and selected water play elements are designed for minimum water consumption. City water systems are a cost effective approach for a splash pad project when water consumption issues are not a concern. Water City Water System reclamation may be routed to a retention pond & used as means of irrigation.

1 Activation Bollard Touch post activator Legend Electrical/Control Wiring 2 Ground Spray Supply Flush spray feature with various nozzle effects Feature Water System 3 Embed Pod Drain Waste Lines Drain to waste to eliminate standing water in ground spray pod 6 1 5 4 Drain to Waste Outlet Main drain to collect all splash pad water to waste 4 5 Water Play Structures 2 Above grade spray feature with various water activities 2 5 6 Drain Line to Waste Take waste water to storm sewer system or retention pond 3

7 Distribution Manifold Pre-plumbed, pre-fabricated with winterization blow-out-port

8 Solenoid Valves 13 Optional on each feature line for sequencing of events 7 9 10 9 Manual Valves Manually control each spray feature’s spray height & distance

10 Main Solenoid Valve 11 On/Off control for splash pad main water supply

11 System Control Panel 8 Controls operational hours, duration of time, sequencing of events, & on/off controls.

12 Main Power Supply Typically 120V, Single Phase, 60 Hz power feed

13 Main Water Supply 12 Municipal water supply with pressure regulator (20 to 30 PSI) & back-flow preventer

Optional Equipment * Above or below grade equipment enclosures & water re-purpose reservoir

Aquatic Recreation Company www.arc4waterplay.com DESIGN CONCEPT PRODUCT SELECTION MECHANICAL OVERVIEW Quote for: Goddard, KS EQUIPMENT & SERVICES 15 SPECIFICATIONS

Water Play Features 1 Water Tent 1 Rotating Water Arch Bar 1 Rotating Mister – SS 2 Custom Aim N Spray – SS 1 Shower Water Dome 1 Mega Water Bucket 1 Sit N Soaker 2 Water Bug 6 Stream Jet 1 Bubbler 2 Junior Geyser 1 Curvy Jet Manifold

Water play feature design notes: • All above water play features are to be the standard product of Aquatic Recreation Company (ARC). • All above ground structures are flange mounted to concrete pad. • All above ground features are offered in the following colors: Red, Orange, Yellow, Green, Blue, Purple, Brown, & White. • All ground spray features are imbed and installed prior to concrete being poured.

Aquatic Recreation Company www.arc4waterplay.com DESIGN CONCEPT PRODUCT SELECTION MECHANICAL OVERVIEW Quote for: Goddard, KS EQUIPMENT & SERVICES 16 SPECIFICATIONS

Mechanical System

Domestic Water System:

1 Activation Bollard To consist of an activation bollard with touch sensor that will signal control panel to activate feature supply system for set duration of time. ARC Model ACT–BP

1 Control Panel – Sequencing To be a UL listed control panel consisting of a programmable control system that will set hours of operation, sequencing of water play elements and activate water flow through a touch censored Activation Bollard.

2 Drain Box To consist of a fiberglass drainage box with grate top.

1 Distribution Manifold – Sequencing To consist of a pre–plumbed distribution manifold with electric solenoid valves for sequencing of water play elements and manual valves for on/off of water supply and for adjusting and distributing water flows to water play elements.

Aquatic Recreation Company www.arc4waterplay.com DESIGN CONCEPT PRODUCT SELECTION MECHANICAL OVERVIEW Quote for: Goddard, KS EQUIPMENT & SERVICES 17 SPECIFICATIONS

Design Services

Design & Construction drawings:

Including: All design and construction drawings for splash pad project construction to consist of construction of concrete pad, mechanical system, electrical and control systems, inbed spray fixtures / collector box installation details, water plays structure assembly / installation on concrete splash pad, equipment systems installation and hookups.

Splash Pad Design Notes: 1. ARC design services are based on ideal site locations and conditions. 2. ARC design services do not include corrections, demolition planning, site elevation plans, utility planning / design or relocation of utilities. (i.e. based on water, waste and power being available at designed area’s of splash pad by others.) 3. All permits and costs of permits are not included in our splash pad design package. 4. Design package will be prepared based on ARC’s interpretation of Local health code. 5. Design & Construction drawings do not include sealed Engineer Stamp.

Any additional drawings associated with project outside of splash pad to be made by others. (sidewalks, landscaping, electrical)

Aquatic Recreation Company www.arc4waterplay.com DESIGN CONCEPT PRODUCT SELECTION MECHANICAL OVERVIEW Quote for: Goddard, KS EQUIPMENT & SERVICES 18 SPECIFICATIONS

Optional Adders Optional Services: Sealed Mechanical & Structural Engineering Stamp – ARC to have drawings stamped by a licensed PE in the State of project.

System Startup and Training – ARC to provide (1) factory direct technician for (2) day of system startup, balancing, and owner training.

Optional Products: Optional Custom Colors– To consist of Gray

*ARC offers on–site supervision and startup services at additional costs. *Equipment Enclosures are offered at additional costs (otherwise mechanical equipment to be stored in above ground equipment enclosure, by others).

Aquatic Recreation Company www.arc4waterplay.com DESIGN CONCEPT PRODUCT SELECTION MECHANICAL OVERVIEW Specifications for: MECHANICAL COMPONENTS EQUIPMENT & SERVICES SPECIFICATIONS 19

Distribution Manifold

Distribution Manifolds are May Consist of: pre-plumbed water delivery systems • Available in Stainless Steel or Schedule 80 Gas Welded PVC prefabricated manifold from feature pumping system to • Manual flow control valves water play features. Standard • Electrical solenoid valves distribution manifolds consist • Winterization blow out of manual flow control valves that • Pressure gauge regulate water flow levels to each water element for on/off control systems. When creating water play zones or sequencing water play activities, standard distribution manifolds can be upgraded with electric valves or solenoid valves.

Aquatic Recreation Company www.arc4waterplay.com DESIGN CONCEPT PRODUCT SELECTION MECHANICAL OVERVIEW Specifications for: MECHANICAL COMPONENTS EQUIPMENT & SERVICES SPECIFICATIONS 20

Activation Bollard

Activation Bollard is a May consist of: structure that has a low • Stainless steel with 150 lb mounting flange voltage proximity sensor • Mounting hardware within the cap of the bollard. • Touch sensor proximity sensor When patrons touch the • Removable domed cap with security screws top of the bollard a signal • 6" base skirt will go to the control panel to activate water flow. Activation bollards are used to turn on/off entire splash pad features or designed zoned areas.

Aquatic Recreation Company www.arc4waterplay.com DESIGN CONCEPT PRODUCT SELECTION MECHANICAL OVERVIEW Specifications for: MECHANICAL COMPONENTS EQUIPMENT & SERVICES SPECIFICATIONS 21

Control Panel

Control Panels are used to All control panels to be U.L. listed and may incorporate the following: control simple on/off operations • Pump(s) motor starters of water play activities or • GFCI circuit breakers • Time clock controls to set hours of operation and set duration time of activated devises incorporate operation interface • VFD pump controls Programmable Logic Controller, • Flow switch controls (PLC), to create splash • Pressure transducer controls pad zoning or sequencing • Power feeds to manifold distribution solenoid valves activities. • Activation Bollard relay switches • Chemical treatment system power feed • Vault internal electrical distribution *All control panels are designed for specific • Waste valve box relay & power feed project needs and require the following GFI • Water heater relay protected power supplies: •All NEMA rated components 230/460V/3PH./60HZ and 120V/Single Phase/60HZ •NEMA 4 enclosure

Aquatic Recreation Company www.arc4waterplay.com DESIGN CONCEPT PRODUCT SELECTION MECHANICAL OVERVIEW Specifications for: MECHANICAL COMPONENTS EQUIPMENT & SERVICES SPECIFICATIONS 22

Drain Box

Drain Box to consist of May consist of: 12 inch fiberglass sump for •Structural plastic grating collection of splash pad • 12 inch sump water to water to waste or • Removable grate cover retainage area. • Foot friendly grate, flush mounted • Drain is offered in a variety of colors

Aquatic Recreation Company www.arc4waterplay.com