JAM72S01 345-365/PR 1500V Percium Series

345-365 1500V Series MECHANICAL DIAGRAMS

Draining Holes Junction Box 8 places

Label 365W Mono Si 72 Cells Mounting holes 4 places for NEXTracker

Grounding holes 6 places

4 places for NEXTracker

Mounting holes 8 places 1500V customized cable length available upon request SPECIFICATIONS OPERATING CONDITIONS

Cell Mono 156.75x156.75mm Maximum System Voltage 1500V DC (UL)

Weight 22.5kg±3% Operating Temperature -40℃~+85℃

Dimensions 1960×991×40mm Maximum Series Fuse 20A 2 Cable Cross Section Size 4mm(12AWG) 2 Maximum Static Load, Front* 5400Pa(112 lb/ft ) Maximum Static Load, Back* 2400Pa (50 lb/ft 2 ) No. of cells 72 (6×12) NOCT 45±2℃ Junction Box IP67, 3 diodes Fire Performance Type 1 Connector Amphenol UTX Application Class Packaging Configuration 27 Per Pallet Class A

ELECTRICAL PARAMETERS AT STC CHARACTERISTICS JAM72S01 JAM72S01 JAM72S01 JAM72S01 JAM72S01 TYPE -345/PR -350/PR -355/PR -360/PR -365/PR Current-Voltage Curve (JAM72S01-355/PR)

Rated Maximum Power (Pmax) [W] 345 350 355 360 365 10 1000W/m2 8 Open Circuit Voltage (Voc) [V] 47.05 47.24 47.45 47.66 47.93 800W/m2 6 2

ent (A) 600W/m

Maximum Power Voltage (Vmp) [V] 38.39 38.58 38.76 38.96 39.21 4 2 Cur r 400W/m

2 Short Circuit Current (Isc) [A] 9.54 9.61 9.69 9.78 9.85 200W/m2 0 0 10 20 30 40 50 Maximum Power Current (Imp) [A] 8.99 9.07 9.16 9.24 9.31 Voltage (V)

Module Efficiency [%] 17.76 18.02 18.28 18.53 18.79

Power Tolerance -0~+5W Power-Voltage Curve (JAM72S01-355/PR)

(α_Isc) +0.060%/℃ 400 1000W/m2 350 2 P r (β_Voc) -0.300%/℃ 300 800W/m 250 600W/m2

200 (γ_Pmp) -0.390%/℃ 2 Power (W) 150 400W/m 100 200W/m2 STC Irradiance 1000W/m²,cell temperature 25℃, AM 1.5G 50 0 0 10 20 30 40 50 Voltage (V) ELECTRICAL PARAMETERS AT NOCT

JAM72S01 JAM72S01 JAM72S01 JAM72S01 JAM72S01 TYPE Current-Voltage Curve (JAM72S01-355/PR) -345/PR -350/PR -355/PR -360/PR -365/PR 10

Max Power (Pmax) [W] 254 257 261 265 268 8

70℃ Harvest the Sunshine 6 55℃ 44.10 44.33 Open Circuit Voltage (Voc) [V] 43.52 43.68 43.88 ent (A) 40℃ 4 Cur r 25℃ Premium Cells, Premium Modules 10℃ Max Power Voltage (Vmp) [V] 35.51 35.78 35.81 36.03 36.25 2

Short Circuit Current (Isc) [A] 7.54 7.61 7.68 7.74 7.80 0 0 10 20 30 40 50 Voltage (V) Max Power Current (Imp) [A] 7.14 7.19 7.29 7.34 7.40 2 ℃ NOCT Irradiance 800 W/m , ambient temperature 20 , wind speed 1 m/s, AM 1.5G

Electrical data in this catalog do not refer to a single module and they are not part of the offer. They only serve for comparison among different module types. US_EN_20171201A www.jasolar.com *For NexTracker installations static loading performances: front load measures 2400Pa while back load measures 1600Pa. Harvest the Sunshine Harvest the Sunshine Premium Cells, Premium Modules Premium Cells, Premium Modules

Percium Cell Average Mass Production Efficiency >21% High Reliability

finger JA Solar Holdings Co., Ltd. The mono cell technology with passivated backside Long-term reliability tests JA Solar Holdings Co.,Ltd is a world leading and local BSF Harsh climate environment endurance tests manufacturer of high-performance >21% average mass production efficiency PID-resistance tests in accordance to IEC62804 products that convert sunlight into electricity for residential, commercial and utility-scale power Certified by TÜV SÜD and ETL generation. The company was founded in May Industry-leading cell technology 2005 and publicly listed on NASDAQ in February n AR Coating High quality components from best suppliers 2007. JA Solar has been the world's leading cell p-silicon producer since 2010, and has firmly established Manufacturing inspected and certified by PI-Berlin and Solar-IF itself as a tier 1 module supplier since 2012. 100% in-house automatic manufacturing Capitalizing on our strength in technology, we are committed to provide passivated layer SiNx Local BSF modules with unparalleled conversion efficiency, yield efficiency, and reliability to enable you to More Power Per m² Benefit: 7% More Power maximize your returns on PV projects. With its Thresher Test

TC 600 DH 3000 leading industry experience, continuous effort on BERLIN UV 45 kW/m2 HF 30 PI Hot Spot 20h Fraunhofer Higher conversion efficiency - more power production PI R&D, customer-oriented service and solid per unit area financial status, JA Solar is your best choice of +7% long-term trustworthy partner.

Add: Building No.8, Nuode Center, Automobile Museum East Road, Fengtai District, , Tel: +86 (10) 63611888

Fax: +86 (10) 63611999

Other Features Email: [email protected] [email protected] Conventional Percium Product Warranty 0~ Positive power tolerance: 0~+5W Percium module 355Wp VS Conventional module 330Wp +5W 12-year product warranty 25-year linear power warranty

Lower System Cost Benefit: Save System Costs Per Watt Modules binned by current to improve system performance

Higher conversion efficiency helps you to save

5400 Transportation costs 7% less 6% less 4% less Pa Excellent mechanical load resistance: Certified to withstand Installation costs high wind loads (2400Pa) and heavy snow loads (5400Pa) BOS costs 2400 Pa

Transportation costs Installation costs BOS costs Additional Insurance Options

SOLAR PowerGuard Cost saving estimation made by comparison between 330W and SPECIALTY INSURANCE SERVICES I N SURAN CE & F I N A NCE 355W modules Comprehensive Certificates

IEC 61215, IEC 61730, UL1703, CEC Listed, MCS and CE Excellent Low-light Benefit:Excellent Low-light Performance Partner Section ISO 9001: 2008: Quality management systems

1.0 Performance Conventional Mono Conventional Poly PERCIUM Mono 102% 0.9 ISO 14001: 2004: Environmental management systems 101% 0.8 100% ) BS OHSAS 18001: 2007: Occupational health and safety management systems % ( 0.7 99% y c

Enhanced spectral response at longer wavelength n e 0.6 i 98% c i f

f Environmental policy: The first solar company in China to complete Intertek's carbon e 97% 0.5 e boosts low-light performance, which can produce more v i t a Current [A] l 96% e

0.4 R footprint evaluation program and receive the green leaf mark verification for our products 95%

than 3% additional power compared with conventional Normalized EQE 0.3 94% module at system side. 0.2 PERCIUM 93% 100 200 300 400 500 600 700 800 900 1000 1100 0.1 Normal Mono Irradiance (W/M2) 0.0 300 400 500 600 700 800 900 1000 1100 Wavelength (nm)

EQE—External quantum efficiency Relative module efficency comparison under different irradiance

Source: