<<

EVANESCENCE® ADDENDUM to the OWNER’S MANUAL IMPORTANT INFORMATION FOR THE INSTALLER AND THE OWNER

INCLUDED: FREESTANDING BATHS INSTALLATION INSTRUCTIONS IMPORTANT: TO BE KEPT FOR THE OWNER FOR BE KEPT TO IMPORTANT: EVANESCENCE ADDENDUM to OWNER’S MANUAL | TMU® PARTS AND TOOLS - SITE PREPARATION

® EVANESCENCE 6634 & EVANESCENCE OVAL 5936, 6636, 7440 PARTS AND TOOLS

® A. PARTS INCLUDED

TMU A-1 Floor anchoring

A-2 Installation template THERMOMASSEUR

B. TOOLS REQUIRED

B-1 48-inch level A-1 x2 A-2 x1

B-2 Caulking gun

B-3 Silicone

B-1

B-2 B-3

EVANESCENCE 6634 & EVANESCENCE OVAL 5936, 6636, 7440

B-4 SiTE PREPARATIONB-5

Evanescence Freestanding models require ACCESS AND AIR INLET a 13” x 14” (33 cm X 36 cm) compartment For these model, the turbine is not installed on the bathtub. for the drain, distance air inlet, and space Determine a location near the bathtub at a maximum distance for control cables and options. Refer to of 15 feet or (4.6 metres) under the floor, in a cabinet or any other the installation template. location to conceal the turbine and optional accessory casings. The location chosen must also be accessible and allow sufficient air intake for the turbine. (Refer to the TURBINE–DISTANCE INSTALLATION section of the Owner’s Manual).

2 1 800 463.2187 From 8 a.m. to 8 p.m. Monday to Thursday (EST) . From 8 a.m. to 5 p.m. on Friday (EST) Printed in Canada. Copyright © December 2017 BainUltra Inc. All rights reserved. 45200599 Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents. EVANESCENCE ADDENDUM to OWNER’S MANUAL | TMU® INSTALLATION

EVANESCENCE 6634 & EVANESCENCE OVAL 5936, 6636, 7440 INSTALLATION

TMU

1. LOCATION ® 1-1 1-2 1-1 Place the installation template on the ground at the chosen location. 2-1 2-2 2-3 2-4 2-5 1-2 Align the position of the overflow drain with the floor drain and ensure that the compart- ment size corresponds to requirements. 3-1 3-2 3-3 3-4 3-5

1-3 Mark the location of the anchor point screws.

1-4 Remove the installation template and screw in the anchor points in the marked locations.

2. INSTALLATION OF BATH Installation Template Example

2-1 Assemble the drain on the bathtub. 1-1 1-2 1-1 1-2 Use the overflow assembly provided for the junction to the drain T-joint. Ensure watertightness. This operation is much easier to complete when the bathtub rests 2-1 2-2 2-3 2-4 2-5 2-1 2-2 2-3 2-4 2-5 on its side. Place a cover or protective cardboard on the floor before positioning the bathtub on its side. 3-1 3-2 3-3 3-4 3-5 3-1 3-2 3-3 3-4 3-5

2-2 Apply a joint of silicone under the edge of the base of the bathtub.

Evanescence Oval 5936, 6636 & 7440 1-1 1-2

1-1 1-2 2-1 2-2 2-3 2-4 2-5

2-1 2-2 2-3 2-4 2-5 3-1 3-2 3-3 3-4 3-5

3-1 3-2 3-3 3-4 3-5

Evanescence 6634

www.bainultra.com 3 Printed in Canada. Copyright © December 2017 BainUltra Inc. All rights reserved. 45200599 Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents. EVANESCENCE ADDENDUM to OWNER’S MANUAL | TMU® INSTALLATION

EVANESCENCE 6634 & EVANESCENCE OVAL 5936, 6636, 7440 INSTALLATION 1-1 1-2 ® 2. INSTALLATION OF BATH (Cont’d)

TMU

2-3 Install the bathtub on the anchor 2-1points 2-2 2-3 2-4 2-5 fastened to the floor and immediately wipe away any excess silicone. Connect the drain. 3-1 3-2 3-3 3-4 3-5 2-4 Install the turbine according to the instructions in the TURBINE – DISTANCE INSTALLATION section of the manual. The air inlet is located to the right of the bathtub drain and, if applicable, control and option connection cables to the right. Connect control and option cables Evanescence 6634 if applicable. For Geysair-equipped baths, also run the water hose and electrical wiring through the floor.

2-5 For Geysair-equipped baths, connect the Geysair electrical wire supplied with the male connector with the turbine cable equipped with the female connector. Test for grounding continuity between the bath grounding terminal and the bath power supply. Failure to perform the grounding continuity test could result in serious personal injury. 1-1 1-2 Evanescence Oval 5936, 6636 & 7440

2-1 2-2 2-3 2-4 2-5

3-1 3-2 3-3 3-4 3-5

Turbine Female Connector Ground Wire for the Bathtub NOTES • T o install the Evanescence Freestanding on a concrete slab with no place for the Geysair Male passage of the air inlet pipe to the Connector bathtub: drill a hole 1 5/8 inches in diameter in the skirt. IMPORTANT: drill the hole 1 1/2 inches above floor level and protect the bathtub with a piece of wood placed behind the location to be drilled.

4 1 800 463.2187 From 8 a.m. to 8 p.m. Monday to Thursday (EST) . From 8 a.m. to 5 p.m. on Friday (EST) Printed in Canada. Copyright © December 2017 BainUltra Inc. All rights reserved. 45200599 Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents.